The following section contains recommendations as to the Molex Premise Networks products that can be used to support most commonly found networking protocols. In most applications, there is more than one set of products that could be used to support a particular protocol. We have chosen a consolidated list for simplicity only. It should be especially noted that, while we list the USO II family of wallplates for category 5e applications and the Synergy family for category 6, in fact they are completely interchangeable. And, the list is just a start. At Molex Premise Networks we offer exten- sive network design services for all of your applications and encourage you to call our toll free technical service at 1-800-866-3827. With full Visio and Autocad support, our team is at your service for your network planning needs. If you prefer the convenience of the internet, we would welcome a visit at www.molexpn.com. Page 98 SYSTEM APPLICATIONS N E T W O R K C H A N N E L S O L U T I O N S A P P L I C A T I O N B A S I C S D E S I G N S E R V I C E S

Transcript of CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS...

Page 1: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

The following section contains recommendations as to theMolex Premise Networks products that can be used tosupport most commonly found networking protocols.In most applications, there is more than one set of products that couldbe used to support a particular protocol. We have chosen a consolidatedlist for simplicity only. It should be especially noted that, while we list the USO II family of wallplates for category 5e applications and the Synergy family for category 6, in fact they are completely interchangeable.

And, the list is just a start. At Molex Premise Networks we offer exten-sive network design services for all of your applications and encourageyou to call our toll free technical service at 1-800-866-3827. With fullVisio and Autocad support, our team is at your service for your networkplanning needs. If you prefer the convenience of the internet, we wouldwelcome a visit at www.molexpn.com.

Page 98

SYSTEM APPLICATIONSN E T W O R K

C H A N N E L S O L U T I O N SA P P L I C A T I O N B A S I C S

D E S I G N S E R V I C E S

Page 2: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

IBM AS400/System 3X APPLICATION BASICSOriginally, IBM AS/400 and System 3X cabling guidelines specified that terminals be daisy-chained from the host using twinax cable. Today twinax isreplaced with unshielded twisted pair cable (UTP) and the daisy-chain is replaced by a bus-wired architecture allowing up to seven devices to be bridgedto one host port. Baluns are used to connect the host and terminals to the twisted pair cabling.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONAttach a Molex Premise Networks twinax balun to the controller and run a line cord to a passive hub in the communications closet. Patch from the hubto a 24 Port HD Patch panel and run UTP cable directly to a USO II wallplate at the workstation. Next, connect a line cord from the wallplate to the terminal using a twinax balun.

HUBHub

Workstation 6

Customer SuppliedAS400 Controller

66

(1)

(3)

(4)

(5)

(6)

(7)(8)

(9)

(10)

(11)

(2)

(12)

Category 5e

Category 6Item Order No. Description Order No. Description1 Customer Supplied AS400 Controller Customer Supplied AS400 Controller2 88-810-80-000 Twinax Balun 88-810-80-000 Twinax Balun 3 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)4 88.00.141.B0044 Mod-Star III Passive Hub – T568A/B 88.00.141.B0044 Mod-Star III Passive Hub – T568A/B5 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)6 PID-00001 HD Patch 5E 24 Port 8W T568B PID- 00066 HD Patch 6 24 Port 8W T568A/B7 Draka-Molex Cat 5E Approved Cable Draka-Molex Cat 6 Approved Cable8 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-01 Synergy 4 Port Wall Plate 9 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module10 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)11 88-810-80-000 Twinax Balun 88-810-80-000 Twinax Balun12 Customer Supplied Terminal Customer Supplied Terminal

Page 99

Page 3: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

IBM 3270 APPLICATION BASICSThe IBM 3270 system utilizes a star topology consisting of an IBM mainframe connected to a controller that is connected to terminals. It was originallydesigned to be installed with 93 ohm coax cable (RG62) and supported communication speeds up to 2.35 Mbps. Baluns are used at the terminals andcontroller to run the signal over 100 ohm twisted pair cabling. It is generally acceptable to use multiple conductor cables (such as 25-pair) to minimizecost and space requirements.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONAttach Molex Premise Networks Twinax baluns to each of the 16 channels of the 3270 controller and connect them to a 16-channel octopus cable.Run a 25-pair feeder cable from the octopus to a 24P Telco Patch Panel. Patch to a 48 Port HD Patch 4 panel and run UTP Cat 5E cable directly to anUSO II wallplate at the workstation. Then, run a line cord from the wallplate to a Twinax balun at the terminal.

Level 5 Area II

66

Customer SuppliedToken Ring MAU

Category 5e

Item Order No. Description1 Customer Supplied 3270 Controller2 88-810-80-000 Balun3 Customer Supplied 16 Channel, 2 Wire Octopus4 Customer Supplied Patch Cord5 PMT-00007 Telco Patch 24P 10/100 BaseT6 PCD-00041-OE Patch Cord C5E (7 ft)7 PID-00002 HD Patch 5E 48 Port 8W 568B8 Draka-Molex Cat 5E Twisted Pair Cable9 WUS-00001-** USO II Single Gang Wall Plate10 MUS-00021-** Cat 5E Double Module 568B/A w/shutter11 PCD-00041-OE Patch Cord C5E (7 ft)12 88-810-80-000 Balun13 Customer Supplied Terminal

(4)(7) (9)

(11)(2)

(3)

(5)(6)

(8)

(10)(12)

(1)

(13)

Page 100

Page 4: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

Modular 10Base-T HubAPPLICATION BASICSThe “T“ in 10BASE-T stands for “twisted” and refers to the twisted-pair wire used for this Ethernet application.

The IEEE 802.3 10BASE-T specification is the standard for Ethernet communication over 100 ohm UTP cabling for local area networks. 10Base-T operates over two pairs of wires, one pair for “receive” data signals and the other pair for “transmit” data signals. The two wires in each pair are twisted together for the entire length of the segment (this improves the signal carrying characteristics). Category 3 cabling is the minimum requirementfor 10Base-T; however, most users are upgrading to Category 5E and beyond. Physical connection for 10Base-T is an 8-wire modular jack.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom a hub with a modular jack interface drop a patch cord to a 24 Port HD patch panel. Run UTP cable from the patch panel to a USO II wallplate atthe work station. Next, connect a line cord from the wallplate to the terminal via a transceiver/network interface card.

HUBHub

Workstation 6

66

Category 5e

Category 6Item Order No. Description Order No. Description1 Customer Supplied 10Base-T Ethernet Hub Customer Supplied 10Base-T Ethernet Hub2 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)3 PID-00001 HD Patch 5E 24 Port 8W T568B PID-00066 HD Patch 6 24 Port 8W T568A/B4 Draka-Molex Approved Cat 5E Cable Draka-Molex Approved Cat 6 Cable5 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate6 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module7 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)8 Customer Supplied Transceiver/Network Interface Card Customer Supplied Transceiver/Network Interface Card9 Customer Supplied Terminal Customer Supplied Terminal

(2)

(3)(5)

(6)

(8)

(1)

(4)

(7)

(9)

Page 101

Page 5: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

25 Pair 10Base-T HubAPPLICATION BASICSThe IEEE 802.3 10BASE-T specification is the standard for Ethernet communication over 100 ohm UTP cabling for local area networks. 10Base-T operates over two pairs of wires, one pair for “receive” data signals and the other pair for “transmit” data signals. The two wires in each pair are twisted together for the entire length of the segment (this improves the signal carrying characteristics). Category 3 cabling is the minimum requirementfor 10Base-T; however, most users are upgrading to Category 5E and beyond. Physical connection for 10Base-T is an 8-wire modular jack.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom a hub with a 25-pair Telco interface, run a feeder cable to a 24 Port Mod Patch Panel in the communications closet. Drop a patch cord from theMod Patch to a 24 Port HD patch panel. Run UTP Category 5E twisted pair cable from the HD patch panel to a USO II wallplate at the work station.Next, connect a line cord from the wallplate to the terminal via a transceiver/network interface card.

1 2 3 4 5 6

7 8 9 10 11 12

13 14 15 16 17 18

19 20 21 22 23 24

PANEL ID

Level 5 Area II

HUBHub

66

Category 5e

Category 6Item Order No. Description Not Applicable1 Customer Supplied 10Base-T Ethernet Hub 2 Customer Supplied Patch Cord3 PMT-00007 Telco Patch 24 Port 10/100 Base-T4 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)5 PID-00001 HD Patch 5E 24 Port 8W T568B PID-00066 HD Patch 6 24 Port 8W T568A/B 6 Draka-Molex Cat 5E Approved Cable Draka-Molex Cat 6 Approved Cable7 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate 8 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module9 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)10 Customer Supplied T ransceiver/Network Interface Card Customer Supplied Transceiver/Network Interface Card11 Customer Supplied Terminal Customer Supplied Terminal

(2)

(3) (5)

(6)

(8)

(9)(1)

(4)

(7)

(10)

(11)

Page 102

Page 6: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

100Base-T (Ethernet)APPLICATION BASICS100Base-T is a networking standard that supports data transfer rates up to 100 Mbps. Because it is 10 times faster than 10Base-T Ethernet, it is oftenreferred to as Fast Ethernet. Like Ethernet, 100Base-T is based on the CSMA/CD LAN access method. There are several different cabling schemes thatcan be used with 100Base-T, including: 100Base-TX (2-pair /Category 5), 100Base-T4 (4-pair/all categories) and 100Base-FX (2-strand optical fiber).

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom a modular hub with an RJ interface run a line cord to a 24 Port HD patch panel. Then, run Category UTP cable to an USO II wall outlet. Next, connect a line cord from the wallplate to the terminal via a transceiver/network interface card.

Workstation 6

HUBHub

66

Category 5e

Category 6 Item Order No. Description Order No. Description1 Customer Supplied 100Base-T Ethernet Hub Customer Supplied 100Base-T Ethernet Hub2 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)3 PID-00001 HD Patch 5E 24 Port 8W T568B PID- 00066 HD Patch 6 24 Port 8W T568A/B4 Draka-Molex Cat 5E Approved Cable Draka-Molex Cat 6 Approved Cable5 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate 6 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module7 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)8 Customer Supplied Transceiver/Network Interface Card Customer Supplied Transceiver/Network Interface Card9 Customer Supplied Terminal Customer Supplied Terminal

Fiber

Item Order No. Description1 Customer Supplied 10Base-T Ethernet Hub2 91.11.621.00200 ST-ST Duplex PC 62.5 2m3 17.B155G 24 Port FMS Termination Drawer4 AFR-00112 6-Pak Plate ST MM5 91.11.621.00200 ST-ST Duplex PC 62.5 2m6 WUS-00001-02 USO II Single Gang Wall Plate7 MUS-00072-01 USO II 6 ST MM (2U) Module8 91.11.621.00200 ST-ST Duplex PC 62.5 2m 9 Customer Supplied Transceiver/Network Interface Card10 Customer Supplied Terminal

(2)

(3)

(5)

(6)

(8)(1)

(4)

(7)

(9)

Page 103

Page 7: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

1000Base-T Copper (Gigabit Ethernet)APPLICATION BASICS1000Base-T is the most current version of Ethernet supporting data transfer rates of up to 1000 Mbps (one gigabit). The initial investment in1000Base-T is in network interface cards (NICs), hubs, switches and the cabling infrastructure. The 1000Base-T standard specifies operation over aninstalled base of Category 5/5E cabling and is backwards compatible with 10/100Base-T, so most system upgrades will not require an additionalinvestment in the cabling. 1000Base-T will also run over the proposed Category 6 and Category 7 copper cabling systems. However, we recommendusing Category 6 components when installing a new system to support the Gigabit Ethernet protocol.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom a 1000Base-T hub with an RJ interface run a patch cord to an 24 Port HD patch panel. Run UTP cable from the patch panel to a USO II wallplateat the work station. Next, connect a line cord from the wallplate to the terminal via a transceiver/network interface card.

HUBHubWorkstation 6

66

Category 5e

Category 6Item Order No. Description Order No. Description1 Customer Supplied 1000Base-T Ethernet Hub Customer Supplied 1000Base-T Ethernet Hub2 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)3 PID-00001 HD Patch 5E 24 Port 8W T568B PID-00066 HD Patch 6 24 Port 8W T568A/B4 Draka-Molex Cat 5E Approved Cable Draka-Molex Cat 6 Approved Cable5 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate 6 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module7 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)8 Customer Supplied Transceiver/Network Interface Card Customer Supplied Transceiver/Network Interface Card9 Customer Supplied Terminal Customer Supplied Terminal

(2)

(3)

(5)

(6)

(8)

(1)

(4)

(7)

(9)

Page 104

Page 8: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

ATM (Asynchronous Transfer Mode) – UTPAPPLICATION BASICSAsynchronous Transfer Mode (ATM) is a transfer protocol that can support megabit to gigabit transfer speeds without being tied to a specific physicalmedium. ATM transmits data in fixed length packets called cells. The Physical layer defines the electrical characteristics and network interfaces. Thislayer “puts the bits on the wire.” ATM is not tied to a specific type of physical transport. Through LAN Emulation (LANE), ATM works with existingEthernet and Token Ring networks.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom an ATM hub with a modular connector interface drop a patch cord to a 48 Port HD patch panel. Run UTP cable from the patch panel to aUSO II wallplate at the work station. Then, connect a line cord from the wallplate to the terminal.

HUBHubWorkstation 6

66

Category 5e

Category 6Item Order No. Description Order No. Description1 Customer Supplied ATM Hub Customer Supplied ATM Hub2 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)3 PID-00002 HD Patch 5E 48 Port 8W T568B PID-00066 HD Patch 6 48 Port 8W T568A/B4 Draka-Molex 5E Approved Cable Draka-Molex Cat 5E Approved Cable5 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate6 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module7 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)8 Customer Supplied Terminal Customer Supplied Terminal

(2)

(3)

(5)

(6)

(1)

(4)

(7)

(8)

Page 105

Page 9: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

Page 106

RS232APPLICATION BASICSThe standard PC comes equipped with two RS232 ports designated as COM1 and COM2 predominantly used for a mouse or modem connection. The PCalso has standard addresses for two additional RS232 ports for other devices requiring a second RS232 card or “COMM CARD.” Typically RS232 cardshave two channels with provision for up to 25 pins each. However, most applications require 8 pins or less and can operate via modular RJ connectors.To accomplish this, a passive adapter is used which separates the send and receive lines into different pairs.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONAttach a 25-pin adapter for each channel to the DTE system device and install a UTP octopus. Run a feeder cable from the octopus to a Mod Telco PatchPanel. Then, connect a patch cord to a 48 Port HD patch panel. Finally, run cable directly from the HD Patch to a USO II wallplate and connect a linecord to the terminal or other device via a 25-pin adapter.

Customer SuppliedMini Computer

Workstation 6

66

Category 5e

Category 6 Item Order No. Description Order No. Description1 Customer Supplied Mini Computer Customer Supplied Controller 2 06-988-999-00 25 Pin Adapter DTE SYS 8W F 3 Customer Supplied 6 Channel, 8W UTP Octopus 4 PMT-00007 Telco Patch 5E 48P 568B 5 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.) 6 PID-00002 HD Patch 5E 48P T568B PID- 00066 HD Patch 6 48P T568B7 Draka-Molex Cat 5E Approved Cable Draka-Molex Cat 6 Approved Cable8 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate 9 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module10 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)11 06-988-999-00 25 Pin Adapter DTE SYS 8W F 06-988-999-00 Pin Adapter DTE SYS 8W F12 Customer Supplied Terminal Customer Supplied Terminal

(2)

(3)

(5)(6)

(8)

(9)

(1)

(4) (7)

(11)(10)

(12)

Page 10: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

Page 107

UTP Token RingAPPLICATION BASICSDeveloped in the 1970s, the Token Ring network is still IBM's primary local area network (LAN) technology and is second only to Ethernet/IEEE 802.3in general LAN popularity. The term Token Ring generally refers to both IBM's Token Ring network and IEEE 802.5 networks as they are almostidentical, although the specification differs slightly. For example, IBM's Token Ring network specifies a star-wired ring topology using a device calledmultistation access unit (MSAU); 802.5 does not. Typically, IBM Token Ring networks use twisted pair cabling.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom a Token Ring MAU with RJ45 interface, run a patch cord to a 24 Port HD patch panel. Run UTP twisted pair cable from the HD patch panel to aUSO II or Synergy wallplate at the work station. Next, connect a line cord from the wallplate to the terminal via a token ring media filter.

Customer SuppliedToken Ring MAU

Workstation 6

66

Category 5e

Category 6Item Order No. Description Order No. Description1 Customer Supplied Token Ring MAU Customer Supplied Token Ring MAU2 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)3 PID-00001 HD Patch 5E 24 Port 8W T568B PID-00066 HD Patch 6 24 Port 8W T568A/B4 Draka-Molex Cat 5E Approved Cable Draka-Molex Cat 6 Approved Cable5 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate6 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module7 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)8 Customer Supplied Token Ring Media Filter Customer Supplied Token Ring Media Filter9 Customer Supplied Terminal Customer Supplied Terminal

(2)

(3)(5)

(6)

(8)

(1)

(4)

(7)

(9)

Page 11: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

Page 108

Terminal ServersAPPLICATION BASICSTerminal Servers are a device which connects many terminals, PCs, printers, modems and other RS-232 devices to a local area network through onenetwork connection. They are a cost-effective, flexible device for connecting terminals to a host in an 802.3/Ethernet LAN. They provide high densityservice and significant savings in cabling and installation. Terminal servers handle asynchronous communications speeds up to 38.4 Kbps.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONDepending on the particular manufacturer, connection to the terminal server will be via Dtype adapters or direct modular connection (RJ). Assuming a50-pin connection, attach a 25-pair adapter for each channel to the terminal server and attach a UTP octopus cable to the adapters. Run a feeder cablefrom the octopus cable to a Mod Telco Patch Panel. Then, connect a patch cord to a 24 Port HD patch panel. Finally, run cable directly from the HDpatch panel to a USO II wallplate at the workstation and connect a line cord to the terminal via a 25 pin adapter.

Customer SuppliedTerminal Drawer

Level 5 Area II

66

6W USOC Channel

Item Order No. Description 1 Customer Supplied Terminal Server2 06-988-999-00 25 Pin Adapter DTESYS 6W F3 Customer Supplied 8 Channel, 6W UTP Octopus4 Customer Supplied Mod Patch 48 Port 6W USOC5 PCD-00040-OE 5 Ft. Patch Cord C5E (7 ft)6 PID-00001 HD Patch 5E 24 Port 8W T568B7 Draka-Molex Cat 5E Twisted Pair Cable8 WUS-00001-** USO II Single Gang Wall Plate9 MUS-00021-** Cat 5E Double Module 568B/A w/shutter10 PCD-00041-OE Patch Cord C5E (7 ft)11 06-988-999-00 25 Pin Adapter DTEDROP 8W F12 Customer Supplied Terminal

(2)

(3)

(5)

(6)(8)

(9)

(1)

(4)

(7)(11)

(10)

(12)

Page 12: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

Page 109

ATM – Fiber SolutionAPPLICATION BASICSAsynchronous Transfer Mode (ATM) is a transfer protocol that can support transfer speeds from 25 Mbps to 2.5 Gbps without being tied to a specificphysical medium, though it was originally designed to operate over optical fiber. ATM is a layered architecture that allows multiple services like voice,data, and video to be mixed over the network.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom the ATM fiber hub run a fiber patch cord to a 24 Port FMS Termination Drawer configured with 6-Pak/Adapter Plates. Run fiber optic cable fromthe termination drawer to a USO II wallplate configured with fiber modules. Connect from the wallplate to the workstation using a fiber patch cord.

HUBATM Fiber Hub

Level 5 Area II

Multimode

SinglemodeItem Part No. Description Order No. Description1 Customer Supplied ATM Fiber Hub Customer Supplied ATM Fiber Hub2a 91.11.621.00200 ST-ST Duplex PC 62.5 µm 2m 91.11.821.00200 ST-ST Duplex PC SM 2m2b 91.11.521.00200 ST-ST Duplex PC 50 µm 2m3 17.B155G 24 Port FMS Term Drawer 17.B155G 24 Port FMS Term Drawer 4 AFR-00112 6-Pak ST MM AFR-00111 6-Pak ST SM 6-Paks5 Draka-Molex Fiber Cable w/connectors Draka-Molex Fiber Cable w/connectors6 WUS-00001-01 USO II Single Gang Wall Plate WUS-00001-01 USO II Single Gang Wall Plate7 MUS-00072-01 USO II 6 ST MM (2U) Module MUS-00071-01 USO II 6 ST SM (2U) Module8a 91.11.621.00200 ST-ST Duplex PC 62.5 µm 2m 91.11.821.00200 ST-ST Duplex PC SM 2m8b 91.11.521.00200 ST-ST Duplex PC 50 µm 2m9 Customer Supplied Workstation Customer Supplied Workstation

(2a/b)

(3)(5)

(6)(8a/b) (9)

(1)

(4)

(7)

Page 13: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

100Base-VG AnyLANAPPLICATION BASICSVG (Voice Grade) is a 100 Mbps Ethernet and Token Ring networking technology ratified by the IEEE 802.12 committee. 100Base-VG AnyLAN is a hub-star topology system developed for use by small workgroups. This design enables it to work over existing 10Base-T twisted pair voice grade cabling nowbeing used for 10 Mbps CSMD/CD or Ethernet networks, making it cost-effective to install.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom a 100VG AnyLAN hub, run a patch cord to a 24 Port HD patch panel. Run UTP cable from the HD patch panel to a USO II wallplate at the work station. Then, connect a line cord from the wallplate to the terminal.

Customer Supplied100VG AnyLAN Hub

Workstation 6

66

Category 5e

Category 6Item Order No. Description Order No. Description1 Customer Supplied 100VG AnyLAN Hub Customer Supplied 100VG AnyLAN hub2 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E C6 Patch Cord 2m (5 ft.)3 PID-00001 HD Patch 5E 24 Port 8W T568B PID-00066 HD Patch 6 24 Port 8W T568A/B4 Draka-Molex Cat 5E Approved Cable Draka-Molex Cat 6 Approved Cable5 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate6 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module7 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)8 Customer Supplied Terminal Customer Supplied Terminal

(2)

(3)

(5)

(6)

(1)

(4)

(7)

(8)

Page 110

Page 14: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

ISDNAPPLICATION BASICSISDN (Integrated Services Digital Network) is a high-speed, fully digital telephone service that works over existing copper telephone wiring. It carriesvoice, data, fax and video. ISDN is available from a server provider either as basic rate of two 64 kbs channels plus a 16 kbs signaling channel or a primary rate of 1.544 mbs. Connection to ISDN services is via PBXs, cluster controllers, LANs, and multiplexers. Typically, the ISDN topology specifies an RJ45 modular jack connector (plug/jack) at the termination points with T568A/B configuration. Terminal devices (digital phones, computers) arestar-wired with each device home run to the network termination.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom the network equipment (controller), run a patch cord to an 24 Port HD patch panel. Run UTP twisted pair cable from the HD patch panel to aUSO II or Synergy wallplate at the work station. Then, connect a line cord from the wallplate to the terminal device.

Customer SuppliedNetwork Termination

Equipment Workstation 6

66

Category 5e

Category 6Item Order No. Description Order No. Description1 Customer Supplied Network Termination Equipment Customer Supplied Network Termination Equipment2 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)3 PID-00001 HD Patch 5E 24 Port 8W T568B PID-00066 HD Patch 6 24 Port 8W T568A/B4 Draka-Molex Cat 5E Approved Cable Draka-Molex Cat 6 Approved Cable5 WUS-00001-01 USO II Single Gang Wall Plate WSY-00002-02 Synergy 4 Port Wall Plate6 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter KSJ-00013-01 DataGate 6 8W T568A/B Module7 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00052-0E Patch Cord C6 2m (5 ft.)8 Customer Supplied Terminal Device Customer Supplied Terminal Device

(2)

(3)

(5)

(6)

(1)

(4)

(7)

(8)

Page 111

Page 15: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

1000Base SX/LX FiberAPPLICATION BASICSBecause of its low loss and high noise immunity, fiber is typically used in Gigabit Ethernet networks for connecting repeaters between buildings and for spanning extended distances as an IRL (Inter-Repeater Link). The IEEE 802.3z task force developed the 1000Base-SX/LX protocol for half and fullduplex transmission to support either multimode or singlemode runs in the cable plant.

SX = Short Wavelength (770-860 nm) MM onlyLX = Long Wavelength (1270-1355 nm) MM and SM

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONFrom the 1000Base-SX/LC hub, run a fiber patch cord to an FMS Plus 72 Fiber Patch Panel configured with ST MM 6-Paks. Run fiber optic cable fromthe FMS Plus to a USO II wallplate configured with ST fiber modules. Connect from the wallplate to the terminal using a fiber patch cord.

Customer Supplied100 Base-SX/LX Hub

Level 5 Area II

Multimode

SinglemodeItem Order No. Description Order No. Description1 Customer Supplied 100Base-SX/LX Hub Customer Supplied 100Base-SX/LX Hub2a 91.11.621.00200 ST-ST Duplex PC 62.5 µm 2m 91.11.821.00200 ST-ST Duplex PC SM 2m2b 91.11.521.00200 ST-ST Duplex PC 50 µm 2m3 RFR-00027 FMS Plus RFR-00027 FMS Plus4 AFR-00112 6-Pak ST MM AFR-00111 6-Pak ST SM5 Customer Supplied Horizontal Fiber Cabling Customer Supplied Horizontal Fiber Cabling6 WUS-00001-01 USO II Single Gang Wall Plate WUS-00001-01 USO II Single Gang Wall Plate7 MUS-00072-01 USO II 6 ST MM (2U) Module MUS-00071-01 USO II 6 ST SM (2U) Module8a 91.11.621.00200 ST-ST Duplex PC 62.5µm 2m 91.11.821.00200 ST-ST Duplex PC SM 2m8b 91.11.521.00200 ST-ST Duplex PC 50 µm 2m9 Customer Supplied Terminal Customer Supplied Terminal

Draka-Molex Draka-Molex

(2)

(3)

(5)

(6)

(8)

(9)(1)

(4)

(7)

Page 112

Page 16: CHANNEL SOLUTIONS - ecswire.com€¦ · SYSTEM APPLICATIONS IBM AS400/System 3X APPLICATION BASICS Originally, IBM AS/400 and System 3X cabling guidelines specified that terminals

SYSTEM APPLICATIONS

TP-PMDAPPLICATION BASICSTP-PMD (Twisted Pair-Physical Media Dependent) is the implementation of FDDI protocols over twisted-pair copper cable providing data rates of 100Mbps and using a star-wired Token Ring architecture. FDDI TP-PMD supports distances of about 100 meters from desktop to concentrator. The ANSI standard (ANSI X3T9.5) recognizes only two types of cables for TP-PMD: shielded twisted pair (STP) and unshielded twisted pair (UTP). STP cablingadheres to EIA/TIA 568A specifications. UTP must be data-grade cabling - Category 5 or higher.

MOLEX PREMISE NETWORKS CHANNEL SOLUTIONIncoming optical fiber is terminated in a 24 Port FMS Termination Drawer with 6-Pak/Adapter Plates. A fiber patch cord connects to the LAN hub. A UTPpatch cord is run from the hub to an 24 Port HD patch panel. C5E UTP cable is run between the panel and a USO II wallplate with C5E module. Then, a patch cord connects the workstation to the wallplate.

HUBHubWorkstation 6

66

Multimode

SinglemodeItem Order No. Description Order No. Description1 17.B155G 24 Port FMS Term Drawer 17.B155G 24 Port FMS Term Drawer2 AFR-00112 6-Pak ST MM AFR-00111 6-Pak ST SM3a 91.11.621.00200 ST-ST Duplex PC 62.5µm 2m 91.11.821.00200 ST-ST Duplex PC SM 2m3b 91.11.521.00200 ST-ST Duplex PC 50 µm 2m4 Customer Supplied High Speed LAN Hub Customer Supplied High Speed LAN Hub5 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00041-0E Patch Cord C5E (7 ft.)6 PID-00001 HD Patch 5E 24 Port 8W T568B PID-00001 HD Patch 5E 24 Port 8W T568B7 Draka-Molex C5E Approved Cable Draka-Molex C5E Approved Cable8 WUS-00001-01 USO II Single Gang Wall Plate WUS-00001-01 USO II Single Gang Wall Plate9 MUS-00021-01 Cat 5E Double Module 568B/A w/shutter MUS-00021-01 Cat 5E Double Module 568B/A w/shutter10 PCD-00041-0E Patch Cord C5E (7 ft.) PCD-00041-0E Patch Cord C5E (7 ft.)11 Customer Supplied Terminal Customer Supplied Terminal

(2)

(3)

(5)

(6)

(8)

(9)

(1)

(4)

(7)

(10)

Page 113