![Page 1: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/1.jpg)
Chandra Calibration StatusChandra Calibration Status
Highlights from the Chandra Calibration Review
New results on the HRMA effective area
Updates to the ACIS contamination model
Flux Cross-Calibration with Other X-ray Telescopes
![Page 2: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/2.jpg)
Proper Stellar Motions with Chandra
![Page 3: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/3.jpg)
Temperature-dependent ACIS gain corrections
![Page 4: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/4.jpg)
![Page 5: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/5.jpg)
![Page 6: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/6.jpg)
Recent HRMA Calibration Results
CALDB Version
![Page 7: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/7.jpg)
![Page 8: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/8.jpg)
![Page 9: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/9.jpg)
![Page 10: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/10.jpg)
![Page 11: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/11.jpg)
![Page 12: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/12.jpg)
Optical depth of the contaminant at the Mn-L and F-K complex on Optical depth of the contaminant at the Mn-L and F-K complex on ACIS-SACIS-S
Updates to the ACIS contamination Model
![Page 13: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/13.jpg)
External Calibration Source (ECS)
Courtesy of Dan McCammon
![Page 14: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/14.jpg)
External Calibration Source (ECS)
![Page 15: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/15.jpg)
External Calibration Source (ECS)
![Page 16: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/16.jpg)
External Calibration Source (ECS)
![Page 17: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/17.jpg)
Surface Roughness of ACIS Filter ContaminantSurface Roughness of ACIS Filter Contaminant
External Calibration Source (ECS)
![Page 18: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/18.jpg)
Effect of Surface Roughness on Measured Optical DepthsEffect of Surface Roughness on Measured Optical Depths
External Calibration Source (ECS)
![Page 19: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/19.jpg)
Revised ACIS Contamination ModelRevised ACIS Contamination Model
CALDB New
![Page 20: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/20.jpg)
The Coma Cluster
1999
2009 CALDB
2009
New
![Page 21: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/21.jpg)
LETG/ACIS-S Observation of Mkn 421LETG/ACIS-S Observation of Mkn 421
CALDB New
![Page 22: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/22.jpg)
Flux Cross-Calibration with Other X-Ray TelescopesFlux Cross-Calibration with Other X-Ray Telescopes
OVII
OVIII
Ne IX
Ne X
![Page 23: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/23.jpg)
Simultaneous Chandra/XMM-Newton AGN ObservationsSimultaneous Chandra/XMM-Newton AGN Observations
![Page 24: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/24.jpg)
![Page 25: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/25.jpg)
![Page 26: Chandra Calibration Status Highlights from the Chandra Calibration Review New results on the HRMA effective area Updates to the ACIS contamination.](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649d5a5503460f94a3a333/html5/thumbnails/26.jpg)
Additional AO-11 Calibration ObservationsAdditional AO-11 Calibration Observations
A set of 5 LETG/ACIS-S observations of Mkn421
A set of 4 observations of Abell 1795 on ACIS-I and ACIS-S
Measure the C-K edge optical depth at the aim-point on S3 with a LETG/ACIS-S observation of Mkn421