Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design...

10
3M True Definition Scanner Chairside Design Station Connections using CC Client Chairside Design Station connections to a 3M True Definition Scanner requires: • Installation of CC Client software by 3M • Configuring 3M True Definition Scanner to connect to Chairside Design Station • One of the following software installed on the Chairside Design Station Workflow File Extension Output Format Fast Design (Glidewell) .udx Plan CAD (Planmeca) .xorder.zip (with password) Dental Wings .xorder Exocad .exo 3Shape .3oxz Open STL .stl

Transcript of Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design...

Page 1: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

3M™ True Definition ScannerChairside Design Station Connections using CC Client

Chairside Design Station connections to a 3M™ True Definition Scanner requires: • Installation of CC Client software by 3M• Configuring 3M™ True Definition Scanner to connect to Chairside Design Station• One of the following software installed on the Chairside Design Station

Workflow File Extension Output FormatFast Design (Glidewell) .udxPlan CAD (Planmeca) .xorder.zip (with password)Dental Wings .xorderExocad .exo3Shape .3oxzOpen STL .stl

Page 2: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

1. Supported Operating Systems Supported: Windows™ 7, Windows™ 8.1, Windows™ 10

2. System Requirements .NET Framework 4.5 is required — this is already installed on Windows 8.1 and Windows 10. If not already installed on Windows 7, the CC Client Installer will install it during the installation process.

3. Installation Procedure — New Installation

Download CCClient_Setup_2.0.10.exe from https://connectioncenter.3m.com/ccclient

This software is necessary to enable data transfer between the 3M™ True Definition Scanner and the computer hosting your dental design software.

Execute: CCClient_Setup_2.0.10.exe. After execution, user access control will appear, click yes.

It’s possible that .NET-Framework 4.5 has not been installed on Windows 7 computers. In that case, it will be installed by the CC Client Installer and the following three windows will appear (Figures 1–5). This may take several minutes to execute — please be patient.

Note: These windows won’t appear for Windows 8.1 and Windows 10 because .NET-Framework 4.5 is already installed.

Installation of CC Client — New Installation

Figure 2

Figure 3

Figure 1

Figure 4

Figure 5

Figure 6

Figure 7

Figure 9

Figure 8

The following screens will appear (Figures 6–9).

Page 3: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

Press “Install”to connect the 3M™ Connection Center Tray Application (Figures 10–11).

Figure 11Figure 10

The network shared folder will be displayed. Use this folder for the Chairside-Connection-Settings on the 3M™ True Definition Scanner (Figures 12–13).

Figure 13Figure 12

If the following message (Figure 14) is displayed (Windows 8.1 / Windows 10), click “More info”, then select “Run anyway”.

Figure 15Figure 14

Installation of CC Client — New Installation (cont.)

Page 4: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

Installation Procedure — Updating from Existing Version to Version 2.0.1 The installation is similar to a “New Installation” with the following differences:

• The selection of the CAD software (Figure 7) does not show up because CAD software from the former installation will be automatically selected.

• The Network Shared Folder Information (Figure 14) does not show up because the shared folder from the former installation remains unchanged (i.e. it is not necessary to change the Chairside-Connection-Settings on 3M™ True Definition Scanner).

CAD Software — Activation / Deactivation After Installation To change the selection of the appropriate CAD software

which should be supported by CC Client, open the context-menu of the 3M™ Connection Center Tray Application by right-clicking on the symbol in the notification area / system tray. Choose “Output Formats” (Figure 18), then select / deselect the appropriate formats (Figure 19). Figure 18

Configuring 3M™ True Definition Scanner to Connect to the Chairside Design StationOnce CC Client is installed and the design station has a dedicated IP address (static IP) or Network Computer Name, proceed to connect your True Definition Scanner to the design station.

1. Activate the Chairside Design Station destination on the True Definition Scanner. From the home screen, select Management.

Figure 19

Page 5: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

a. Once Management is selected, choose Destinations on the left side of the screen.

b. Once Destinations is selected, highlight the Chairside Design Station — the Destination will turn blue. Once highlighted, select De/Activate to change the status of lab from inactive to active.

Page 6: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

2. Once the Destination is active on the 3M™ True Definition Scanner, the Chairside connection will need to be completed. To complete from the Management > Settings screen, select Chairside on the left side of the screen.

a. After Chairside is selected, click on New to create a new chairside connection.

Page 7: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

b. Once New is selected, the Connection Settings will be available on the right of the 3M™ True Definition Scanner screen.

c. All fields need to be complete in the Connection Settings on the True Definition Scanner. Select the text box under Connection Name. This field will show up on the Rx screen when filling out the Rx for a scanned case. Example: Dr Chairside. Once name is entered, click OK.

Page 8: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

d. Then click on Associated Destination and select the Chairside Design Station lab.

e. The next field is for Network Computer Name or IP Address. Enter the Network Computer name or the Static IP address, then click OK.

Page 9: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

f. Once completed, click on the text box under Network Shared Folder, enter “TrueDefImport”, the click OK.

g. The next two fields are for the username and password associated with the network computer or the IP address of the computer that will be connected with the 3M™ True Definition Scanner. Enter the username and the network password, then click Save.

Page 10: Chairside Design Station Connections using CC Client Client Quick Start... · Chairside Design Station Connections using CC Client ... • One of the following software installed

h. Once saved, click Test to confirm that the scanner is properly setup. The design station must be powered on for the test to be successful.

Note:Iftheconnectionisnotsuccessful,confirmthenetworkcomputername/IPaddress,usernameandpasswordwere entered correctly. If further assistance is needed, please contact your 3M regional service center for assistance.

Using the 3M™ True Definition Scanner with Your Chairside Design StationWorkflow Output Folder File Extension Output FormatFast Design C:\UdxImport .udxPlan CAD C:\d4d\lava .xorder.zip (with password)Dental Wings C:\XOrder\XOrderIn .xorderExocad C:\TrueDefCases .exo3Shape C:\3M\CCClient\3OXZ .3oxzOpen STL C:\3M\CCClient\STL .stl

Customer Care Center: 1-800-634-2249, option 3, option 1 3M.com/TrueDef

3M is a trademark of 3M. Used under license in Canada. Please recycle. Printed in U.S.A. All other trademarks are the property of their respective owners. © 3M 2017. All rights reserved.

3M CanadaPost Office Box 5757London, Ontario N6A 4T1Canada1-888-363-3685

3M Oral Care2510 Conway AvenueSt. Paul, MN 55144-1000 USA

Phone 1-800-634-2249 Web www.3M.com/TrueDef