1 Ensto Chago Oy Kipinätie 1, P.O. Box 77 FIN-06101 Porvoo, Finland Tel. +358 20 47 621 Customer service: [email protected] [email protected] www.chago.com 30.3.2017 Chago Pro and Chago Premium EVF200/100 and EVC200/100 Installation instruction Operation instruction

Transcript of Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using...

Page 1: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

1

Ensto Chago OyKipinätie 1, P.O. Box 77FIN-06101 Porvoo, FinlandTel. +358 20 47 621Customer service: [email protected]@ensto.comwww.chago.com

30.3.2017

Chago Pro and Chago Premium EVF200/100 and EVC200/100

Installation instruction

Operation instruction

Page 2: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

2

ContentsEnsto Chago Pro and Ensto Chago Premium 3Safety Instructions 3Delivery Contains 3Order Sets Example 5Installation Accessories 6Installation 9Before Installation 12Ground Mounting Installation 12

Ground Mounting on Concrete 12Ground Mounting on Ground Mounting Frame 13Ground Mounting on Unimi Concrete Foundation 16

Wall Mounting Installation 18Supply Connection 20Commissioning 21User Instructions 22

Free Charging 22Start Charging with RFID 22Stop Charging with RFID 22

Installation / Commissioning Checklist 23Maintenance / Preventive Maintenance Instructions 24Troubleshooting 25Technical Information 26Dimension Drawing 28Wiring diagram 32

Page 3: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

3

Ensto Chago ProEnsto Chago Pro (EVF) is a solution for the charging of one or two electric vehicles. It is engineered es-pecially for fast AC charging (22kW/3x32A), but the station can be equipped also with domestic sockets (1x16A).

3-color LED indicates the charg-ing point’s status

Optionally compartment for domestic socket Type F/E/G with or without lockable hatch

Hinged maintenance compart-ment allows easy access to electrical components

Mode 3 compatible EV charging

Diverse variety of communica-tion and connectivity options: Ethernet, 3G

User identification via RFID tag or mobile phone / app

Compatible basic charging modules allows modularity based on customer’s needs

Safety Instructions• Chago Pro and Premium must be installed by a qualified person.• Read the instruction manual before installation and usage of the charging station.• The instruction manual must be stored in a safe location and be available for future installation and

service.• Follow the guidelines in the instruction manual when installing and using the charging station.• The installation must be done according to the local safety regulations, restrictions, dimensioning,

codes and standards.• The information provided in this manual in no way exempts the user of responsibility to follow all

applicable codes and safety standards.

Delivery Contains• EVF or EVC charging station• Installation and Operation instruction

Note! The delivery does not include any installation accessories. Please order needed accessories based on following order sets.

Page 4: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

4

Ensto Chago PremiumEnsto Chago Premium (EVC) is a solution for the charging of one or two electric vehicles. It is engineered especially for fast AC charging (22kW/3x32A), station is also equipped also with domestic sockets (1x16A).

3-color LED indicates the charg-ing point’s status

Mode 3 Type 2 socket andDomestic socket

Acid proof steel

Mode 3 compatible EV chargingwith a lockable hatch.

Diverse variety of communica-tion and connectivity options: Ethernet, 3G

User identification via RFID tag or mobile phone / app

Compatible basic charging modules allows modularity based on customer’s needs

Safety Instructions• Chago Pro Premium must be installed by a qualified person.• Read the instruction manual before installation and usage of the charging station.• The instruction manual must be stored in a safe location and be available for future installation and

service.• Follow the guidelines in the instruction manual when installing and using the charging station.• The installation must be done according to the local safety regulations, restrictions, dimensioning,

codes and standards.• The information provided in this manual in no way exempts the user of responsibility to follow all

applicable codes and safety standards.

Delivery Contains• EVC charging station• Installation and Operation instruction

Note! The delivery does not include any installation accessories. Please order needed accessories based on following order sets.

Maintenance compartment allows easy access to electrical components

Page 5: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

5

Order Sets ExampleOrder accessories depending on mounting method.

Ground mounting on concrete

EVF200/100 and EVC200Charging station

EVTL32.00:Ground mounting box, cable entry from bottom

or

EVTL34.00:Ground mounting box,cable entry from top

Please order suitable anchor bolts separately from a local supplier.

Ground mounting on ground mount-ing frame

EVTL28.00:Ground mounting frame

Ground mounting on Unimi concrete foundation

Unimi Concrete Founda-tion, see www.unimi.se

Wall mounting

EVF200/100Charging station

EVTL31.00:Wall installation kit including installation rail and box

Page 6: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

6

Installation AccessoriesOrder numbers and dimensions.

Ground Mounting Box EVC200 and EVF200/100

EVTL32.00

EVTL32.00 is a ground mounting box with cable entry from bottom.

Ground Mounting box EVC200 and EVF200/100

EVTL34.00

EVTL34.00 is a ground mounting box with cable entry from top.

182

M8

576415

466391

110

182

Ø 14

80(133

)

(120

)

17

269

110

112

Ø 14

360

574415262

330100

M8

338

39

Cable entry

Cable glands M40x1.5

Cable glands M40x1.5

Cable entry

Cable route

Page 7: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

7

Ground mounting frame EVC200 and EVF200/100EVTL28.00

EVTL28.00 is a whole set as shown on the picture.

578

415

415

289

M12110

Ø115

184

110 92

380

490

63

886

Page 8: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

8

Wall installation kit EVF200/100

EVTL31.00

EVTL31.00 is a wall installation kit including installation rail and box. Note! This installation kit is only available for EVF produc not for EVC (Chago Premium product)

360

320

90

100

366576

105 105269

330

100

80(4

5)12

61.5

8050

580

580

(51.

5)13

85

Cable glands M40x1.5

Page 9: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

9

Ground mounting frame EVC100EVTL46.00

EVTL46.00 is a whole set as shown on the picture.

Page 10: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

10

Ground mounting frame EVC100EVTL47.00

EVTL47.00 is a whole set as shown on the picture.

Page 11: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

11

Ground mounting box EVC100EVTL42.00

EVTL42.00 is a whole set as shown on the picture.

Page 12: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

12

Installation

Before InstallationRemove the package around the EVF/EVC. Remove the film protecting the metal parts only after the in-stallation is finished.

When selecting the installation location, take into consideration the minimum space needed for operat-ing and maintenance. Note that EVC does not have hinges on the maintanance door!• 1000 mm in front of the maintenance space• 150 mm around the charging point

Ground Mounting Installation

On ground mounting installations make shure that proper cable glands are used for feed in cables and the bottom pass thru plate seals any holes on the bottom.!

Ground Mounting on Concrete

Items needed: 1 pcs Ground Mounting box EVTL32.00 or EVTL34.00 or EVTL42.00 4 pcs Anchor bolts M12 Washers Nuts

Make sure that the materials used for the concrete foundation and the installation procedures follow local building regulations and safety standards.

• Dig a pit for the concrete foundation. The pit floor should be trampled and horizontal. • Put cable and possible drain pipes in place. • Fill the pit with concrete. • Let the concrete solidify, make sure the surface stays solid and level during the process.

180

1000

150

Page 13: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

13

Installation Steps1. Drill a hole in the concrete for the anchor bolts. For more information see the anchor bolt instruc-

tions. Use the ground mounting box as a jig.2. Put the anchor bolts in place and tighten the anchor bolt nuts.3. Adjust nuts and washers on the anchor bolts horizontally.

4. Place the ground mounting box on the concrete.5. Attach the mounting box to the anchor bolts using suitable washers and nuts.6. EVTL32.00: Pull the supply cable(s) and possible data cable through the ground mounting box cable

gland(s) approx. 400 mm measured from the upper surface of the mounting box. EVTL34.00: Pull the supply cable(s) and possible data cable through the ground mounting box cable gland(s) and further through the mounting box cable hole approx. 400 mm measured from the up-per surface of the mounting box.

7. Tighten the cable gland. Close the unused cable entries with cable gland plugs.

41511

0

43 (EVTL32.00)38 (EVTL34.00)

M12

150

(64)

86

Cable protection pipe 0110

Washer upper surface meas-ured from ground level

Horizontaladjustment

Anchor bolt

Concrete

Select anchor bolts depending on the thickness and strength of the concrete

Page 14: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

14

8. EVTL32.00: Remove the supply cable sheath at the length of max. 200 mm.EVTL34.00: Remove the supply cable sheath beginning from the cable gland exit.

9. Open the maintenance door.10. Remove the nuts and washers from the ground mounting box.11. Lift the EVF/EVC on the ground mounting box and pull the supply cable(s) and possible data cable

through the cable hole.12. Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads in different lengths and strip them at the length of 25 mm.14. Connect the supply cable leads to the power connectors. 15. Ensure that the PE is connected to the EVF/EVC. 16. Switch on F0, F1, F2 (if present) and QF1. 17. Close the maintenance door.

Ground Mounting on Ground Mounting FrameItems needed: 1 pcs Ground mounting frame EVTL28.00 1 pcs Ground mounting box EVTL32.00 or EVTL34.00

Make sure that the materials used for the concrete foundation and the installation procedures follow local building regulations and safety standards.

• Plan the installation depth so that the top surface of the ground mounting frame is not below the ground surface.

• Dig a ca 490 mm deep hole in the ground. The pit floor should be trampled and horizontal• Place the ground mounting frame in the hole. • Put cable and possible drain pipes in place. • Pour concrete over the frame and pipes. • Let the concrete solidify, make sure the surface stays solid and level during the process.

Ground mounting box EVTL32.00

Use EVTL32.00 holes as a drilling jig

Page 15: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

15

Installation Steps1. Remove the upper nuts and washers on the top of the ground mounting frame bolts.2. Place the mounting box on the mounting frame.3. Adjust the the nuts on the mounting frame bolts so that the top surface of the mounting box is

horizontal.4. EVTL32.00: Pull the supply cable(s) and possible data cable through the ground mounting box cable

gland(s) approx. 400 mm measured from the upper end of the mounting box. EVTL34.00: Pull the supply cable(s) and possible data cable through the ground mounting box cable gland(s) and further through the mounting box cable hole approx. 400 mm measured from the up-per end of the mounting box.

5. Tighten the cable gland. Close the unused cable entries with cable gland plugs.6. EVTL32.00: Remove the supply cable sheath at the length of max. 200 mm.

EVTL34.00: Remove the supply cable sheath beginning from the cable gland exit.7. Open the maintenance door.8. Lift the EVF on the mounting box and pull the supply cable(s) and possible data cable through the

cable hole.9. Bolt the EVF in place using the washers and nuts you removed from the mounting frame bolts. 10. Cut the supply cable leads in different lengths and strip them at the length of 25 mm.11. Connect the supply cable leads to the power connectors. 12. Ensure that the PE is connected to the EVF/EVC. 13. Switch on F0, F1, F2 (if present) and QF1. 14. Close the maintenance door.

80 (E

VTL3

4.00

)46

(EVT

L32.

00)

(25)

400

~500

415

min. R900

(800

110

M12 Thread bar

Ground level

Ground mounting frame EVTL28.00

Concrete

Ground mounting box EVTL32.00 orEVTL34.00

Cable protection pipe

Page 16: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

16

Ground Mounting on Unimi Concrete FoundationThis installation example describes the installation procedure using a concrete foundation supplied by Unimi - Solutions.

Items needed: 1 pcs Ground mounting box EVTL32.00 or EVTL34.00 or EVTL42.00 Please order the following items from www.unimi.se 1 pcs Concrete foundation Chago Pro, product code 100-1 1 pcs Cover plate 1 pcs Ensto EVF compatible adapter element, product code 100-13

Installation Steps

Figure 1• Prepare trenching for cable conduits and the con-

crete foundation to necessary depths.• Add gravel to the bottom of the trench, to such thick-

ness that the top of the foundation will reach desired level when lifted into the hole. Note! Consider the possible paving materials when setting the level.

• Cover the unused conduit openings with plugs ac-companying the foundation.

• Lift the foundation into the installation hole, the at-tachment bar embedded in the foundation can be used as a lifting point. The attachment bar should be oriented to allow attachment of the EVF into desired position.

• Lay the cable conduits into the trenches and install conduits to relevant inlets.

• Pull electric cables through the conduits into the foundation.

Figure 2• Tighten the foundation to its place by filling the

excess space outside the foundation with gravel. • Set the final layer of gravel so that the top of the

foundation will be flush with ground or the final paving material.

• Always place a cover plate on the foundation if the EVF charging station is installed in a separate ses-sion than the foundation.

Figure 3• When starting the installation of the EVF/EVC

charging station remove the cover plate.

1

2

3

Page 17: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

17

Figure 4• Place the adapter element on the foundation and

tighten the captive screws, 3 pcs.• Remove the upper nuts and upper pair of washers

from the adapter element. (Ensure there is one poly-amide washer on each side of the mounting box.)

• Pull the supply cable and possible data cable through the hole in the center of adapter approx. 450 mm measured from the upper surface of the adapter.

Figure 5• Place the mounting box on the adapter element. • Bolt the mounting box in place using the washers

and nuts you removed from the adapter element. (Ensure there is one polyamide washer on each side of the mounting box.)

• Hint: to make it easier to ascertain that the mount-ing box is levelled, first flip it upside down and posi-tion the nuts under it so that it becomes levelled and then flip it over again and tighten the upper nuts and washers.

• EVTL32.00: Pull the supply cable(s) and possible data cable through the ground mounting box cable gland(s). EVTL34.00: Pull the supply cable(s) and possible data cable through the ground mounting box cable gland(s) and further through the mounting box ca-ble hole.

• Tighten the cable gland. Close the unused cable en-tries with cable gland plugs.

Figure 6• Open the maintenance door.• Lift the EVF on the mounting box and pull the

supply cable(s) and possible data cable through the cable hole(s).

• Bolt the EVF in place using suitable washers and nuts.

• EVTL32.00: Remove the supply cable sheath at the length of max. 200 mm.EVTL34.00: Remove the supply cable sheath be-ginning from the cable gland exit.

• Cut the supply cable leads in different lengths and strip them at the length of 25 mm.

• Connect the supply cable leads to the power connectors.

• Ensure that the PE is connected to the EVF. • Switch on F0, F1, F2 (if present) and QF1. • Close the maintenance door.

6

Ø115

(x4)

250395

450

600 Ø15

5

Bolt the EVF in place

4

Page 18: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

18

Wall Mounting Installation

Note! Wall mounting is not available for EVC200 units! Items needed: 1 pcs Wall mounting kit EVTL31.00 Screws or bolts Washers

2379 74,5

Attach the top part of the EVF/EVC to the wall bracket with adhesive tape

Installation rail

Install to wall with 6 pcs screws / bolts Ø 16

Remove the cable sheath beginning from the cable gland exit

Supply cable direction

Pull the cable leads through the mounting box hole

Bolt the EVF on the mounting box

Mounting box

Screws and sealing washers

Secure the EVF with screws

Page 19: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

19

Nuts

Installation steps1. Ensure that the wall is robust and stable. The mounting surface must be flat and vertical.2. Prepare the wall for installation and select the screw / bolt type depending on the wall type. Excer-

cise extreme caution when drilling holes in the wall. 3. Install the wall mounting kit EVTL31.00 on the wall using 6 pcs of suitable screws / bolts, washers

and nuts.4. Adjust the installation rail so that the mounting box is perpendicular to the ground.5. Pull the supply cable(s) and possible data cable through the cable gland(s) on wall mounting bracket

roof approx. 2 m. 6. Alternative cable entry is from mounting box sides. 7. Pull the supply cable(s) and possible data cable through the cable gland(s) on the mounting box.8. Tighten the cable glands. Close the unused cable entries with cable gland plugs.9. Remove the supply cable sheath, beginning from the cable gland exit.10. Open the maintenance door.11. Lift the EVF on the mounting box and pull the supply cable leads through the cable hole.12. Bolt the EVF in place. 13. Attach the top part of the EVF to the wall mounting bracket with adhesive tape (included the deliv-

ery).14. Drill 2 pcs holes through the EVF enclosure and top bar of the wall mounting bracket; 74.5 mm

measured from inside the enclosure. Make sure not to damage any components or internal wiring when drilling the holes.

15. Secure the EVF to the wall bracket with screws and sealing washers (included the delivery). Place the sealing washer between the screw and the enclosure.

16. Cut the supply cable leads in different lengths and strip them at the length of 25 mm.17. Connect the supply cable leads to the power connectors. 18. Ensure that the PE is connected to the EVF. 19. Switch on F0, F1, F2 (if present) and QF1. 20. Close the maintenance door.

Page 20: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

20

Supply Connection The voltage and current ratings including cables and line protector dimensioning must comply with na-tional regulations. System dimensioning must be done by a qualified electrical designer.

Possible supply connections:• Use separate supply cables for each charging point• Use one supply cable and chain internally to the charging points

L3L1 L2N PE

Page 21: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

21

CommissioningBefore commissioning the Chago Pro or Premium unit must be installed according to the installation in-structions.

By default all EVF and EVC products are operating in free charging mode (standalone operation). In this free charging mode external communication (3G, optional Ethernet) is not active. If the product is going to be connected to some back-office (online mode), first make sure that the basic function ality is working before establishing communication.

NOTE: More detailed configuration instructions are available that explain the different configuration use cases. For that refer to the controller configuration manual “ComissioninEnstoChagoChargers.pdf” that can be downloaded from https://wiki.chago.com/display/public/CHWI/Installation+Instructions. Also more infromation can be found from https://wiki.chago.com.

Connecting to EVF and EVC controller unitIf you want to change the default settings, you must connect to the units controller via web configuration tool to be able to proceed with the commissioning settings.

Below image shows how to connect the a computer to the charging station controller unit with USB cable. For this a USB A to USB Micro B cable is needed. (This cable usually comes for example with Android mobile phones)

NOTE: On EVF200 and EVC200 units always connect USB cable to the right side controller unit

The USB cable micro end is the one connected to the chargers controller.Insert the USB cable so that the longer edge of the is facing away from you.

Do not remove any existing USB devices from any of the controller units!

Page 22: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

22

Charging

Free charging• Plug in your electric vehicle to start charging.• Unplug your electric vehicle to stop charging.

Charging with RFIDYou must have an RFID tag which has a permission to access the charging point.

Start Charging with RFID• When the charging point is free and the indicator light shows green, you can start a charging event.• Show the RFID tag to the RFID reading area.• When the RFID tag is read, the charging point will flash green and verify the user permission to

charge. If the user login is failed, the indicator light turns to red. If the user login is passed, the indica-tor light turns to waving green.

• Now you are logged in to the charging station. • Plug in the electric vehicle for charging. The indicator light turns to stable blue.

Stop Charging with RFID• Show the RFID tag to the RFID reading area.• When you stop the charging event, the indicator light turns to waving green and you are able to

unplug the charging cable. • After you have unplugged, you are logged out from the charging point and the charging point is

free for the next user.

User Instructions

User Interfaces

LED signal lights will show the status of the charging point as described below:

Charging point status LED light LED operation

Charging point free and ready to use Green Stable

RFID read, user login ongoing Green Flashing

User login fail, access denied Red Stable

User loggin passed, charging allowed Green Waving

While connecting the cable Green Flashing twice

Vehicle connected, charging not started Blue Waving

Vehicle connected, starts charging Blue Waving

Charging ongoing Blue Stable

Error state Red Stable

Page 23: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

23

Installation / Commissioning Checklist

IntroductionThis checklist is a guidance for ensuring both mechanical and electrical installation as well as commission-ing of the Chago Pro or Premium.

Before InstallationRead the product specific installation instructions before performing any actions.

Note! Only trained electrician may perform the installation in accordance with the applicable lo-cal and national electrical rules and standards.

Checking the InstallationGo through the visual, mechanical and electrical installation when the charging point is un-powered.

CATEGORY X ITEM NOTES

Overall look Ordered material has been received.

Protective plastic wrapping have been removed.

No scratches or damages may be seen.

Mechanical installation

Charging point is fixed properly on the wall.

The front cover opens and closes smoothly.

Electrical installation

Charging point’s power supply capacity meets electrical planning (cable size, MCB…).

Review local electrical design plan.

Gently push the charging point with a hand to create vibration to ensure no bad contact / connec-tion exist (wire or PCB).

Gently push the controller to create vibration to ensure no bad contact / connection exist (wire or PCB).

Check tightness of the PE-cable screw.

Power supply cables (L1, L2, L3, N and PE) are properly connected.

Insulation of power supply cables is intact (L1, L2, L3, N and PE)

Voltage between PE and N is less than 10 V

PE quality is less than 3 Ω

Operational check

All the LED states / color (green, blue, red) and RFID reader is functioning.

Create fail and charge (with RFID tag). Red at bootup, green at idle and blue while charging.

Available electricity at the sockets. All the contacts (L1, L2, L3) must be tested.

Use Mode 3 tester.

Verify that when charging point LED is green, there is no power at the socket contact (L1, L2, L3, N).

With Mode 3 tester, test the functioning of Mode 3 (from green to blue).

Page 24: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

24

Maintenance / Preventive Maintenance Instructions 1 x per year

WARNING! Danger of electrical shock or injury. Disconnect power before working inside the device or removing any components.

X MAINTENANCE ACTION

Retighten all screws (electric components).

Check the Mode 3 socket and if needed change it (burn or parts damage) (socket cost not under warranty).

Check the charging cable and if needed change it.

Check the sealings.

Gently push the charging point with a hand to create vibration to ensure no bad contact / connec-tion exist (wire or PCB).

Gently push the controller to create vibration to ensure no bad contact / connection exist (wire or PCB).

Create fail and charge (with RFID card) to check all the LED states / color (green, blue, red) and RFID reader is functioning.

Test available electricity at the sockets; use Mode 3 tester if needed. All the contacts (L1, L2, L3 must be tested).

With Mode 3 tester, test the functioning of Mode 3 (from green to blue).

Check tightness of the PE-cable screw.

Test voltage between PE and N (must be less than 10 V).

Test PE quality (must be less than 3 Ω).

SW update if needed (if in service contract).

Restart the station from F0, ensure it will restart properly.

Maintanance performed by: Date:

Page 25: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

25

Troubleshooting

Charging station is off, no lights on

Issue Corrective action

Mains voltage does not exist in supply connec-tor L1.

Ensure proper power supply.

Circuit breaker F0 is off. Turn F0 on.

12V power unit has no LED on. Ensure 230V power supply to 12V power unit; if ok re-place the power unit.

The controller has no PWR LED on. Ensure power supply to the controller; if ok replace the controller.

Charging cable is locked in Mode 3 socket outlet

Issue Corrective action

Unexpected fault has occurred while power is on.

Option 1:If equipped with Mode 3 lock release functionality, turn off the power from F0 and pull charging cable out from the socket.Option 2:Turn off the power. Switch Mode 3 lock manually into open position.

Power is off. Open the front cover. Switch Mode 3 lock into open position. Note! If the station has a Mode 3 Lock Release functionality, then during power cut the Mode 3 lock opens automatically.

Configuration via web browser

Issue Corrective action

PC does not recognize micro USB plug and con-nection to the controller cannot be established via web browser.

Check from Windows 7 / 10 operating system settings via “Device Manager” that RNDIS network adapter is available. If not, update the related Windows driver.

Page 26: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

26

Technical Information

Electrical connections

Nominal voltage 230 Vp-n / 400 Vp-p

Nominal current2× 32 A (Mode 3 socket) On EVF as Option and on EVC: 2 x 16A (Domestic socket)Only either Mode 3 or Domestic socket can be in use at the time

Nominal frequency AC 50 Hz

Rated power supply

EVF100: • 22kW: 1x 3x32A EVF200: • 22kW per charging outlet: 2x 3x32A EVC100: • 22kW 1x 3x32AEVC200: • 22kW per charging outlet: 2x 3x32AOptionally: • Dynamic load management (DLM) based on available power

supply• Static current limitation

Supply connections and terminals

L1, L2, L3, N, PECu 2.5 - 50 mm², Al 6 - 50 mm²Tightening torque Nm: 4 Nm (2.5 - 4 mm²), 12 Nm (6 - 50 mm²)

Design and mechanics

Material / color

EVC Acid proof brushed steel

EVF Painted aluminum and stainless steel Two basic colors:• RAL9016S “Traffic White”• RAL7021 “Anthracite”

Enclosure class IP54

IK class IK10

Operating temperature -30 ... +55 oC

Directive LVD directive 2006/95/ECEMC 2004/108/ECRoHS 2011/65/EC

Standard EN61439-1EN61439-3

Operation and communication according to IEC 61851-1

Approvals / Markings CE

Page 27: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

27

Features

No. of simultaneous users

EVF100: 1 userEVF200: 2 usersEVC100: 1 userEVC200: 2 users

Connection to carDefault: Mode 3 charging, Type 2 / Type 3Option: Mode 2 charging, Type F / E / G

Lockable lid for Mode 3 socket EVC product only

Lockable lid for Domestic socket Option for EVF products

Charging status indication LED: • Blue = Charging• Green = Available• Red = Malfunction

User access & control Standalone mode: • Default: Free use, RFIDOnline mode: • Option: RFID reader (ISO/IEC 1443A / B, ISO/IEC 15693)• Option: Mobile like SMS, call, app (through communication

interfaces)• Option: Remote control (through communication interfaces)

Energy measurement Default: Current transformers (per charging point)Option: MID class kWh metering (per charging point)

Safety features

Over-current protection (MCB) Default

Residual current protection (RCD) Default: Type A (30mA AC)Option: Type B (6mA DC)

Automatic reset of RCD and RCD remote test

Option

Automatic release for Mode 3 socket in case of sudden power outage

Option

Surge, overvoltage protection Option

Low control voltage 12 VDC Default

Connectivity and Communication

ConnectivityDefault: GSM (3G)Option: Ethernet

Communication Default: OCPP 1.5 or OCPP1.6, both fully implemented.

WarrantyWarranty conditions, see www.ensto.com.

Page 28: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

28

EVF200 Dimension DrawingChago Pro with two charging points.Note! Domestic sockets optional.

176 575

579180

1375

1329

46

180

110º

490

(90º

507

mm

)

Page 29: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

29

EVF100 Dimension DrawingChago Pro with one charging point. The side of the charging point can be placed on the right or the left side based on customer request.Note! Domestic sockets optional.

176 572

576

1375

(132

9)46

345

510

1227

Page 30: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

30

EVC200 Dimension DrawingChago Premium with two charging points.

Page 31: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

31

EVC100 Dimension DrawingChago Premium with one charging point

Page 32: Chago Pro and Chago Premium EVF200/100 and EVC200/100€¦ · Bolt the EVF/EVC in place using washers and nuts you removed from ground mounting box. 13. Cut the supply cable leads

32

13

67

89

10 5

C1

Em

ergen

cyO

pen

er

NL +

42

T0

12

VD

C -

L1L2

L3

PEN

Ligh

tin

ing c

urr

ent

Pro

tect

or

V1

P1

En

ergy M

eter

L1 L1L2

L2

L3L3

18

17

16

15

13

N

13

A1

24

A2

K2

Con

tact

or

TYPE

3

TYPE

2

-+Lock

Mag

net

N MC

B 21

BU

RD

GN

LED

2

LED

1

RFI

D

RFI

D B

oar

d

LED

Boar

d

TYPE

FTY

PE E

TYPE

G14

11

14

13

L1

L2

L3

F1 MC

B

L1

L2

L3

L1 L1L2

L2

L3L3

NN

RC

CB

QF1

M1

RC

CB M

oto

r

14

11

12

LN

I

F0 FU

SEB6 21

2T

1

1L1

4T

2

3L2

6T

3

5L3

Mai

n

Swit

ch

Q0

Key

Switc

h

PP

32

32

OPT

ION

Star

t

Pu

sh B

utt

on

OPT

ION

BK

RD

BR

/BU

RD

/BU

BK

RD

Pow

er

IN A

C

IN A

C

PLC

ERR

RD

Y

AN

TEN

NA

RG

B2

RG

B1

+

PE

(M5)

OUT N

OUT L2

OUT L1

IN L3

IN L2

12V

ING

ND

INCP

PR

A4A3

A2A1

PE

PE

IN N

IN L1

XST1

103

1

XST4

003

1

XST4

002

1

XST4001

1

XST1

200

1

XST1

102

1

XST1

101

1

XST1

100

1

XBU

6000

XBU1020181

XBU1020081

XB

U11

008

14

1

XST9

000

1

XBU

0300

0

OUT L3

A1

CH

AG

OW

ALL

BO

XC

on

troll

er

XBU

8000

XBU

8001

CT

EX OUT 2EX OUT 2EX OUT 1EX OUT 1

I2C PowerI2C SDAI2C CLKI2C GND

S0 Power

RS485 AS0 Data

RS485 B

OPTO 2 -OPTO 2 +OPTO 1 -OPTO 1 +

MCB1 IN

MCB2 IN

RCD IN

EX SOCKET IN

GND

GND

GND

GNDEX IN 1

EX IN 2

GND

GND

XST1

201

1R

FID

EHZ

XK

L600

1XK

L600

0XK

L600

2

43

21

43

21

21

Current

XKL11000

IC11

000

XKL8002XKL8001 XKL8000

WH

ITE

XST8000

1

XST5000

1

XBU

1000

12V

OU

TG

ND

OU

T

EX

OU

T 2

EX

OU

T 2

TES

TR

CD

RE

SE

TR

CD

EX

SO

CK

ET

OU

T

USB M

INI U

SB

WH

Eth

ern

et O

PT

ION

USB

to E

ther

net

T2

12V

DIO

DE

NL +

T1

12V

DC -

++

OU

T

++

IN

Q0

NNL1

L2

L3

F1 MC

B

L1

L2

L3

N NNN

F2 FUSE

B6 21

Piir

ikaa

vio

sove

ltuu

EV

F ve

rsio

lle:

EV

F100

-...

EV

F50-

...

EV

F50-

...E

VF1

00-..

.

Ens

to/M

J

RLi

-08.0

3.20

17

EV

F -c

harg

ing

stat

ion;

Wiri

ng d

iagr

am o

f mai

n ci

rcui

ts a

nd c

ontro

lsE

VF

-lata

uspy

lvää

n pä

ävirt

apiir

ien

ja o

hjau

sten

johd

otus

kaav

io

EVC and EVF internal wiring diagram (one insert) Both of the EVF200 and EVC200 inserts are the same and one USB capble is connected between the controllers. With EVF100 and EVC100 there is only one insert.