Ch -8 Equipment Maintenance
Transcript of Ch -8 Equipment Maintenance
-
8/14/2019 Ch -8 Equipment Maintenance
1/45
8. EquipmentMaintenance
SpecificationCalibration
Operating
Prevention Maintenance
http://opt/scribd/conversion/tmp/scratch2313/slide4.xmlhttp://opt/scribd/conversion/tmp/scratch2313/slide4.xml -
8/14/2019 Ch -8 Equipment Maintenance
2/45
Terminology
Ketepatan Kecapaian bacaan dengannilai sebenar kuantiti yang diukur.
Kejituan Darjah perbezaan ukuran yg
didapati antara satu kumpulan datadengan yg lain.
Kepekaan Gerakbalas jangka kpd
perubahan masukan & pembolehubahyang diukur.
-
8/14/2019 Ch -8 Equipment Maintenance
3/45
Multimeter
A multimeter is an electronic measuring
instrument that combines several functions inone unit. The most basic instruments includean ammeter, voltmeter, and ohmmeter. Analogmultimeters are sometimes referred to as
"volt-ohm-meters.Useful for basic fault finding and field servicework or a bench instrument which can measureto seven or eight and a half digits of accuracy.
Can be used to characterise resistance andvoltage standards or adjust and verify the
performance of multi-function calibrators.
-
8/14/2019 Ch -8 Equipment Maintenance
4/45
Current, voltage, and resistancemeasurements are considered standard
features for multimeter. AVO multimeters, amanufacturer of early multimeters, derivedtheir name from amperes, volts, and ohms,the units used for the measurement ofcurrent, voltage, and resistance.
Implemented with an analog meterdeflected by an electromagnet, as a classicgalvanometer.
Using suitable switching arrangement forfunction & range selection.
-
8/14/2019 Ch -8 Equipment Maintenance
5/45
Safety Rules for Multimeter
1. Before making measurement, check if thefunction & range is set at proper position.
2. Always start with this instrument from thehighest range of the function to measured. Paycareful attention to the max. rated voltage of
each range & i/p terminal.3. Never ground yourself when taking electrical
measurements. Keep your body isolated fromground by using dry clothing, rubber shoes,
rubber mats, or any suitable & approvedinsulating material.
4. Disconnect line power @ i/p signal beforeaccessing fuse.
-
8/14/2019 Ch -8 Equipment Maintenance
6/45
Note :
1. Indication of zero correction. Before measuring, placethe pointer on zero position of the scale left byadjusting the screw of zero corrector.
2. Range selection. When measuring unknown value ofvoltage @ current, start from the highest range, thenadjust to a proper lower range. Measurement is moreaccurate as near to the full scale, for resistancemeasurement, near to the middle scale.
3. Converting the range selector.4. As range change is desired, remove test leads from
source to be tested, then convert selector. This willextend the life of selector contact.
5. OFF Range. After measurement, place range selector
to OFF range. This is to prevent pointer from swaying& to protect multitester.
-
8/14/2019 Ch -8 Equipment Maintenance
7/45Specification of multimeter
-
8/14/2019 Ch -8 Equipment Maintenance
8/45Specification
-
8/14/2019 Ch -8 Equipment Maintenance
9/45
How to use multimeter in a correct way?
Select correct range mode
For better sensitivity, select the nearer value range modeto the measured value. i.e 1.5V battery should use range
mode of 2.5V DC. Error is bigger at the right scale. Forresistance mode the most reliable value is at the center scale.
Unknown value measurement
Start with the highest value. After the first reading value,set the range mode to lower for more reliable reading value.
Safe keeping meter
Vibration or shock situation should be avoided because thisequipment is very sensitive.
Failure because of wrong operating method
Internal resistance broken when high AC voltage measuredat current & resistance mode.
High voltage cct (
-
8/14/2019 Ch -8 Equipment Maintenance
10/45
Method of measurement [DCV & ACV]
1. Place range selector to a proper range on DCVposition.
2. Plug short end of red test lead to + connector,& shortend black test lead to - connector.
3. Connect the other long ends of test leads to thetested load or current in parallel.
4. Read the value indicated on DCV scale.
1. Place range selector to a proper range on ACV
position.
2. Plug short ends of test leads each to + & -connectors & connect the long ends of testleads to the tested circuit in parallel.
3. Read the value indicated on ACV scale.
-
8/14/2019 Ch -8 Equipment Maintenance
11/45
Method of DCV measurement [DCmA & Resistance]
1. Place range selector to a proper range on DCmA position.
2. Plug short end of red test lead to + connector, & short end blacktest lead to - connector.
3. Connect the long ends of test leads to the tested current in series.4. Read the value indicated on DCV scale.
1. Place range selector to a proper range on position.
2. Plug short ends of test leads each to + & -. 0 adj.
3. Separate long end of 2 test leads,then connect to the tested point
4. Read the value indicated on scale.
* As for 0 adjustment, it is unable to place the pointer to 0 line,check battery. If battery power is not sufficient, replace immediately.As measuring a resistor in circuit, turn off the source first.
-
8/14/2019 Ch -8 Equipment Maintenance
12/45
-
8/14/2019 Ch -8 Equipment Maintenance
13/45
Used as an ammeter, an analogue multimeter has avery low resistance and is very sensitive, withscales down to 50 A. More expensive digital
multimeters can equal or better this performance.Most modern multimeters are digital andtraditional analogue types are destined to becomeobsolete.
Meter DArsonval system movement are based on 3force ( daya) :-
1. Daya kilas pesongan akibat kesan magnet,elektrostatik & elektromagnet.
2. Daya kilas kawalan disebabkan sistembergerak kembali i.e. spring.
3. Daya kilas redaman Pergerakan sistem meterpenunjuk.
-
8/14/2019 Ch -8 Equipment Maintenance
14/45
Digital Multimeter
Basic DM is consist of Analog to digital converterand Also known as multi function meter @ VOM
(volt-ohm-miliampere) meter.Newer equipment can measure many otherquantities. Some common additional measuredquantities and the units in which they aremeasured:
Inductance in henrys.
Capacitance in farads.
Conductance in siemens.
Temperature in degrees
Frequency in hertz.
Duty cycle as a percentage.
Implemented with a digital display such as an LCD
-
8/14/2019 Ch -8 Equipment Maintenance
15/45
Digital multimeter
AutorangingSwitch range
-
8/14/2019 Ch -8 Equipment Maintenance
16/45
Operating Method
The central knob has lots of positions.Choose the most appropriate position. Ifthe meter is switched to 20 V DC, then20 V is the max voltage which can bemeasured, This is sometimes called 20 V
fsd (full scale deflection).For circuits with supplies up to 20 V, the20 V DC voltage range is the mostuseful. DC ranges are indicated by on
the meter. To measure smaller voltages,the 2 V or 200 mV ranges are used.
Cli k t dit M t t t t l
-
8/14/2019 Ch -8 Equipment Maintenance
17/45
Click to edit Master text stylesSecond level
Third level Fourth level
Fifth level
M th d f t [DCV & ACV]
-
8/14/2019 Ch -8 Equipment Maintenance
18/45
Method of measurement [DCV & ACV]
1. Select the V function.
2. Set the range switch to the desire range.
3. If measuring DCV, select AC/DC switch to DC. Ifmeasuring ACV, select AC/DC switch to AC.
4. Connect black test lead to COM& red to V- i/p.
5. Connect test lead to the measuring point & read the
displayed value.Method of measurement [DCA & ACA]
1. Select the mA function.
2. Set the range to the desire range.
3. If measuring DC, select AC/DC switch to DC. Ifmeasuring AC, select AC/DC switch to AC.
4. Connect black test lead to COM i/p terminal & red testlead to A or 20A i/p.
-
8/14/2019 Ch -8 Equipment Maintenance
19/45
Operating Method
DC means direct current. In any circuitwhich operates from a steady voltagesource, such as a battery, current flow isalways in the same direction.
AC means alternating current. In an electriclamp connected to the domestic mainselectricity, current flows first one way, thenthe other. That is, the current reverses, or
alternates, in direction. With UK mains, thecurrent reverses 50 times per second.
-
8/14/2019 Ch -8 Equipment Maintenance
20/45
Megger / Megaohmmeter
A megger is a circuit tester which puts a very highvoltage at a very low current across two conductors tomake sure that they are properly insulated. The nameis short for megohm-meter
The Meter are used to :-
1. Measure very high resistance.
2. Measure insulated conductor i.e. cable
Type of megger :-
1. Hand driven generator (penguja terengkoltangan)
2. Battery power
- Digital meter
- Analog meter
-
8/14/2019 Ch -8 Equipment Maintenance
21/45
4 types of basic testing wiring that are usingMegaohm meter
Cable Continuity Test (Gelang) - To determinewhether a circuit is open or closed.
Cable Continuity Test ( Pengalir pelindung)
Insulation Resistance Test To determine the
strength of conductor insulator between thephase line conductor. (2 or more) Whethershort cct occur at the cct.
Pole Test To makesure all one pole control
device like fuse, suis satu hala satu kutub is atthe life point.
-
8/14/2019 Ch -8 Equipment Maintenance
22/45
4 types of earthing efficiency testingthat are using Megaohm meter
Ujian bagi pengalir pelindung &pengikat
Ujian galangan gelung bumi
Ujian pemutus litar bocor ke bumi
Ujian rintangan elektrod bumi
-
8/14/2019 Ch -8 Equipment Maintenance
23/45
Operating Method
The moving element of the ohm meter consistsof two coils, A and B, which are rigidly mountedto a pivoted central shaft and are free to rotate
over a C-shaped core (C on Figure 17). Thesecoils are connected by means of flexible leads.The moving element may point in any meterposition when the generator is not in operation.
As current provided by the hand-driven
generator flows through Coil B, the coil will tendto set itself at right angles to the field of thepermanent magnet. With the test terminalsopen, giving an infinite resistance, no currentflows in Coil A. Thereby, Coil B will govern themotion of the rotating element, causing it to
move to the extreme counter-clockwiseposition, which is marked as infinite resistance.
-
8/14/2019 Ch -8 Equipment Maintenance
24/45
Coil A is wound in a manner to produce aclockwise torque on the moving element. Withthe terminals marked "line" and "earth"shorted, giving a zero resistance, the currentflow through the Coil A is sufficient to produceenough torque to overcome the torque of CoilB. The pointer then moves to the extremeclockwise position, which is marked as zeroresistance. Resistance (Rl) will protect Coil A
from excessive current flow in this condition.When an unknown resistance is connectedacross the test terminals, line and earth, theopposing torques of Coils A and B balance eachother so that the instrument pointer comes to
rest at some point on the scale. The scale iscalibrated such that the pointer directlyindicates the value of resistance beingmeasured.
-
8/14/2019 Ch -8 Equipment Maintenance
25/45
AB
C
Megohmmeter
-
8/14/2019 Ch -8 Equipment Maintenance
26/45
-
8/14/2019 Ch -8 Equipment Maintenance
27/45
An original "Megger" from World War II
-
8/14/2019 Ch -8 Equipment Maintenance
28/45
Comparison between Ohm Meter & Megger
Voltan Kenaan until 24V 500, 1000, 2500, 5000 VJulat Pengukuran Kohm Megaohm
Meter ohm Megger
How to use megger?n Connect line probe to the measureddevice & the gnd probe to the earth.
n Voltage supply generate by the hand
driven generatorn Insulation failure will be shown on the
scale.
-
8/14/2019 Ch -8 Equipment Maintenance
29/45
Measured data should be analyze by the experience person.
Measured data usually 500V @ 1000V DC taken in 1 minute.
Example of measure data & the analyze data :-
- Reading > 50 Mohm cable in good condition- Reading 2-50 Mohm maybe long cct, slightly
damp or cantamination
- the analyze data might
not be true
- Reading < 2Mohm maybe the insulation not
in good condition
-
8/14/2019 Ch -8 Equipment Maintenance
30/45
-
8/14/2019 Ch -8 Equipment Maintenance
31/45
Wattmeter / Power meter
The wattmeter is an electrodynamicinstrument for measuring or record the
electric power @ the supply rate ofelectrical energy of any given cct/ used bythe customer.
The device consists of a pair of fixed coils,known as current coils, and a movable coilknown as thepotential coil.
The current coils are connected in serieswith the cct, while the potential coil isconnected across the line.
-
8/14/2019 Ch -8 Equipment Maintenance
32/45
Also, the potential coil carries a needle thatmoves over a scale to indicate themeasurement.
A current flowing through the current coilgenerates an electromagnetic field around thecoil.
The strength of this field is proportional to theline current & in phase with it.
The potential coil has a high-value resistorconnected in series with it to reduce the
current that flows through it
h d fl i f h dl i
-
8/14/2019 Ch -8 Equipment Maintenance
33/45
On a DC cct, the deflection of the needle isproportional to both the current & thevoltage, thus conforming to the equation
W=VA or P=EI.
On an AC cct the deflection is proportional tothe average instantaneous product of voltage
& current, thus measuring true power, andpossibly (depending on load characteristics)showing a different reading to that obtainedby simply multiplying the readings showing
on a stand-alone voltmeter and a stand-aloneammeter in the same circuit.
-
8/14/2019 Ch -8 Equipment Maintenance
34/45
The two circuits of a wattmeter are likely to bedamaged by excessive current. The ammeter andvoltmeter are both vulnerable to overheating - incase of an overload, their pointers will be driven off
scale - but in the wattmeter, either or even both thecurrent and potential circuits can overheat withoutthe pointer approaching the end of the scale! This isbecause the position of the pointer depends on thepower factor, voltage and current.
Thus, a circuit with a low power factor will give a lowreading on the wattmeter, even when both of itscircuits are loaded to the maximum safety limit.Therefore, a wattmeter is rated not only in watts,
but also in volts and amperes.
-
8/14/2019 Ch -8 Equipment Maintenance
35/45
How is it operates?
1. Bila voltan diguna, cakera aluminium
berputar.2. Dan dgn itu menggerakkan susunan gear
kepada gear utk menghitung.
3.
Kelajuan cakera aluminium berkadar dgnhasil darab voltan yang dibekal dgn arussefasa.
4. Hasil darab islah no watt yg digunakan
oleh setiap putaran cakera.5. Tenaga yg digunakandirakam dgn
menggunakan nombor putaran.
-
8/14/2019 Ch -8 Equipment Maintenance
36/45
Wattmeter
-
8/14/2019 Ch -8 Equipment Maintenance
37/45
A V
To loadLN
W
Connection between Watt meter with load
H t tt t ?
-
8/14/2019 Ch -8 Equipment Maintenance
38/45
How to use watt meter?
1. Before connect the meter to the cct :-
- Adjust the position of zero.
- Choose the range mode same or above the
supply voltage.
- Start with the higest range mode, then select
the mode that gave the highest scale movement.
2. Current cct connected series with the load.
3. Voltage cct connect parallel with the load.
4. If the needle meter move to the left side of zeroposition, current @ voltage terminal should be
change the position.
-
8/14/2019 Ch -8 Equipment Maintenance
39/45
There is 3 type of watt meter / powermeter adjustment :-
1. Pelaras kelajuan utama
2. Pelaras kelajuan induktif Bilafaktor kuasa meter tenaga kurang drnilai yg ditetapkan.
3. Pelaras geseran Apabila dayakilas penimbal utk atasi geseran padabearing
O ill
-
8/14/2019 Ch -8 Equipment Maintenance
40/45
Oscilloscope
Electronic test equipment that allowssignal voltages to be viewed, usually as a
two-dimensional graph of one or moreelectrical potential differences (verticalaxis) plotted as a function of time or ofsome other voltage (horizontal axis).
Amplitude measurements Volt p-p Xvolt/div
Time period measurements 1 cycle X
time/div
Frequency - 1 / Time period
-
8/14/2019 Ch -8 Equipment Maintenance
41/45
-
8/14/2019 Ch -8 Equipment Maintenance
42/45
Method of oscilloscope measurement
1. For the first time use, the oscilloscope must
be calibrated to ensure all the result frommeasurement will be accurate.
2. Select the probe setting to 1X.
3. Place the probe to 0.5 cal pin. Make sure theclip on the probe clipped on the ground.
4. Turn on the oscilloscope and see on the CRTdisplays if any waveform displayed. A square
waveform should appear.5. Calculate the peak-to-peak amplitude (Vpp)
and the measured value should same withthe 0.5 cal pin.
-
8/14/2019 Ch -8 Equipment Maintenance
43/45
Prevention Maintenance & Troubleshooting
Meter
1. Multimeter is a precision instrument, so
storage at high temp. on in moisture should beavoided. The suitable operating temp. is from 0 C 40 C & humidity is below 80%.
2. Take battery out for long time storagebecause battery may leak to make interiorcomponents deteriorated.
3. Severe stroke @ drop should be avoided.
4. Do not get close to any circumstance there isa powerful magnetic field.
5. Usually user facing problem needle meter
cannot adjust to 0 always check battery.1.5V x1 /x10 and 9V x1k /x10k
6 M t t f ti
-
8/14/2019 Ch -8 Equipment Maintenance
44/45
6. Meter not function :-
- range mode wrong selection
- protection fuse open open andcheck
the continuity of the fuse.
7. Always check the continuity of thetester
probe.
-
8/14/2019 Ch -8 Equipment Maintenance
45/45
Prevention Maintenance & Troubleshooting
Oscilloscope
1. Equipment composed of high precision
components/ high internal pressure care is requiredin handling & storing.
2. Occasionally, clean the graticule scale/ controlbutton with a clean, soft cloth.
3. Ideal ambient temp for storing -10 C - 60 C
4. To maintain the effeciency of the equipment -
Service osc. Every 1000 hours operating time
@ 1 year.