CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS...

23
Duraisamy P Sr. Development Engineer CFD analysis of ceiling fan by Lucas TVS Limited 22nd July 2016

Transcript of CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS...

Page 1: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

Duraisamy P

Sr. Development Engineer

CFD analysis of ceiling fan

by

Lucas TVS Limited

22nd July 2016

Page 2: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

2

Company profile

Established 1962, JV - Lucas UK and TVS

Wholly owned since 2001

7 plants in India

Main plant in Chennai - 2600 employees

Complete Product development capability 75% of revenue from products

developed In-house

TS16949 and OHSAS 18001 certified company

Deming grand prize in 2012 for excellence in applying the principles of

TQM

Page 3: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

3

Products

Page 4: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

4

CFD analysis of ceiling fan

Objective of case study

To perform flow simulation of ceiling fan.

Analyse the fluid flow and predicted results.

Establish correlation with experimental data.

Page 5: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

5

Geometry Nomenclature and Spec

Top canopy

Downrod

Blade

Blade flange

Specifications

Fan sweep 1200 mm

No of blade 3

Blade thickness 1.2 mm

Fan speed 350 RPM

Range of speed 280-350 RPM

Rotation CCW from floor

Evaluate flow rate as per IS 374 -1979 specification.

Determine mechanical input power

Page 6: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

6

IS 374-1979 spec - test chamber

Page 7: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

7

Virtual flow chamber

4.2

5 m

Page 8: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

8

Virtual chamber surfaces

Floor

Bottom opening

Outer wall

Roof

Top opening

Test chamber wall

Page 9: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

9

Diaphragm - Top opening and Rot domain

Enlarged View

Top opening recommanded diameter is 1.1 to 1.2 times of fan sweep diameter.

Fan - Rotating domain

Page 10: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

10

Surface and Volume mesh

Mesh - Cut section view

Surface Mesh

Boundary layer mesh created over blade surfaces. Conical mesh created to capture flow under fan region.

Surface mesh created in HM.Surface mesh can constrcut volume.

Page 11: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

11

Input details and Boundary conditions

Material properties: Input speed:

Density of air 1.2 kg/m3

Viscosity of air 1.8 e-5 Ns/m2

Boundary Condition:

• Wall BC to all the outer walls.

• No BC to rot domain surfaces.

• Pressure point is created in domain

to initiate simulation.

Page 12: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

12

Velocity measurement points

Test chamber wall

Probe points at four semi diagonalsbegins at 40 mm from centre and 80 mm incremental in all diagonals.

The measurement plane located 1.5 m below plane of fan blades.

Mesurement points are shown below which are used to read value of velocity.

Page 13: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

13

Solution convergence - AcuProbe

Page 14: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

14

Stream lines

Air entering into top opening and fan moves air with higher velocity.

Air comes out through bottom opening from chamber and circulated.

Page 15: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

15

Velocity contour

X Z plane - velocity contour

Z axis component velocity contour shown below

Page 16: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

16

Velocity contour cont..

X Y plane - velocity contour

0.01 m 0.5 m

1 m 1.5 m

Page 17: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

17

CFD results

Steady state analysis performed.Velocity evaluated at discrete points of four semi diagonals.Geometry position - A blade oriented to Y axis.

0 Deg

Page 18: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

18

CFD results - Three different initial positions

Accumulated air flow rate : 242 CMMTorque required to develop flow : 0.75 Nm @ 350 rpm

0 Deg30 Deg

60 Deg

Page 19: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

19

Test results

Velocity profile along four semi - diagonals are shown below.

Accumulated air flow rate : 231 CMMTorque : 0.74 Nm @ 350 rpm

Page 20: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

20

Comparision

S No Parameters Test results CFD results Remarks

1Flow domain

size

IS 374 - 1979

followed

IS 374 - 1979

followed

Thickness of chamber neglected

2Speed

RPM350 350

Input for simulation

3Flow rate

CMM231 242 5% variation

4 Torque

Nm0.74 0.75 2% variation

5Power

W27 W 27.5 2% variation

Page 21: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

21

AcuSolve could predict the flow parameters for given input speed of ceiling fan

by

1. Flow rate >95 % accuracy.

2. Torque >95% accuracy

Conclusion

Page 22: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

22

Benefits summary

Flow simulation method has been established to evaluate airflow rate and mechanical input power of fan as per IS 374 - 1979 specification.

This methodology proposed to optimize fan blade design in order to improve efficiency.

Page 23: CFD analysis of ceiling fan by Lucas TVS Limited · CFD analysis of ceiling fan by Lucas TVS Limited ... Objective of case study ... Lucas TVS providing the permission to present

23

I would like to acknowlegde

1. The excellent support provided - M/s DesignTech sys Ltd

2. Lucas TVS providing the permission to present fan simulation work in ATC 2016

Acknowledgements/Credits