5
Photo/isometric drawing provided by manufacturer Roger Bullivant Limited In-situ Thermaslab Sub-Floor System Description of Product Roger Bullivant Limited In-situ Thermaslab Sub-Floor System is a cast in-situ ribbed concrete floor. Key Factors Assessed Mechanical Resistance & Stability Validity This certificate was first issued on 8 th December 2011 and is valid until 8 th December 2021 Issue Dated 22 nd November 2018 Certificate No: EW29C

Transcript of Certificate No: EW29C - LABC

Photo/isometric drawing

provided by manufacturer

Roger Bullivant Limited In-situ Thermaslab Sub-Floor System

Description of Product

Roger Bullivant Limited In-situ Thermaslab

Sub-Floor System is a cast in-situ ribbed

concrete floor.

Key Factors Assessed

Mechanical Resistance & Stability

Validity

This certificate was first issued on 8th December 2011 and is valid until 8th December 2021

Issue Dated 22nd November 2018

Certificate No: EW29C

This Registered Detail relates to the In- situ Thermaslab Sub-Floor System. It is a cast in-situ ribbed concrete floor designed

to carry floor and internal wall loads at ground floor level in domestic buildings, using polystyrene permanent formwork.

The system is for use solely with the Roger Bullivant Tee Beam systems.

The design shown and materials specified shall not be changed without reference to the local authority responsible for certifying

the system.

Where reference is made to any Code of Practice, British Standard or manufacturer’s instructions it shall be construed as a

reference to such publication in the form in which it is in force at the date of this certificate.

LABC consider that, Roger Bullivant Limited In-situ Thermaslab Sub-Floor System, will meet the

functional requirements of the Building Regulations (listed below) if the criteria detailed in this

certificate are met;

The Building Regulations 2010 (as amended) England & Wales

AD A Structure

Note: The system meets this Requirement subject to limitations detailed in Conditions

section.

The Building Regulations 2010 (as amended) England

None presently

The Building Regulations 2010 (as amended) Wales

None presently

The Building (Scotland) Regulations 2004 (as amended)

If you would like to discuss a specific use of the product in Scotland it will require an additional

assessment under the Scottish Building Regulations and accordingly you should contact the LABSS

STAS Administrator at www.labss.org

LABC Warranty

The use of the Roger Bullivant Limited In-situ Thermaslab Sub-Floor System has not been assessed

to meet the requirements of the LABC Warranty Technical Manual. If you would like to discuss a

specific use please make an enquiry to [email protected]

Drawings RBCITS/CS01 (14mm bar)

RBCITS/CS02 (12mm bar)

RBCITS/CS03 (10mm bar)

RBCITS/SP1 (Section Properties)

RBCITS/SH1 (Service Holes)

RBCITS/CD03 – 24

RBCITS/CD25 – 43

BBA Certificate number 04/4190, issued 24 December 2004

Roger Bullivant Limited In-situ Thermaslab Sub-Floor System Design Manual 1999

Product Conformity Certification, UK Certification Authority for Reinforcing Steels, certificate number 920601, 01.01.2002-

31.12.2002

Product Conformity Certification, UK Certification Authority for Reinforcing Steels, certificate number 0141, 01.01.2002-31.12.2002

Thermaslab Structural Calculations, job reference CITS, Nov 02

Thermal Calculations, job ref: CITS, Dec 02

Test Report on Thermodeck flooring panels, Version 1.003, issued Jan 2002

Roger Bullivant Limited Load Test, 15.01.2002 and 07.03.2002

Roger Bullivant Limited Quality Assurance, Form WP/01/F4, Iss 2 Rev 0

Roger Bullivant Limited

RB Walton Park

Hearthcote Road

Swadlincote

Derbyshire

DE11 9DU

Tel: 01332 977300

Email: [email protected]