CERAMIC DENTAL IMPLANT SOLUTIONS · IMPLANTS Powered by CeramTec MT-00624-2008-EN-01 CeramTec GmbH...

1
CERAMIC DENTAL IMPLANTS Powered by CeramTec MT-00624-2008-EN-01 CeramTec GmbH | Medical Products Division CeramTec-Platz 1–9 D-73207 Plochingen Mike Moynihan +49 7153 611 916 [email protected] www.densilox.com The depicted DENSILOX ® implants as well as dental products made of ceramic foam are under development and are not approved by any authorities. CERAMIC DENTAL IMPLANT SOLUTIONS Thanks to the natural colouring and excellent biocompatibility of ceramic dental implants, more and more implantologists and patients show a preference for these materials. Based on 45 years of development, manufacturing and testing of ceramic medical devices, CeramTec has become a trusted partner to develop your innovative ceramic implant solution. 1 Strong All DENSILOX ® ceramics demonstrate high hardness as well as high fracture strength and toughness. 2 Aesthetic You can choose DENSILOX ® ceramics in a range of colours for an individual solution and for the highest aesthetic demand: natural white, ivory or ‘gingiva pink’. 3 Metal-free All DENSILOX ® ceramic materials are 100% metal-free and demonstrate low biofilm adhesion. References CeramTec Internal Data. Cosgarea R, Gasparik C, Dudea D, Culic B, Dannewitz B, Sculean A. Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study. Clin Oral Implants Res. 2015;26(5):537-544. doi:10.1111/clr.12440. de Medeiros RA, Vechiato-Filho AJ, Pellizzer EP, Mazaro JV, dos Santos DM, Goiato MC. Analysis of the peri-implant soft tissues in contact with zirconia abutments: an evidence-based literature review. J Contemp Dent Pract. 2013;14(3):567- 572. doi:10.5005/jp-journals-10024-1364. Kajiwara N, Masaki C, Mukaibo T, Kondo Y, Nakamoto T, Hosokawa R. Soft tissue biological response to zirconia and metal implant abutments compared with natural tooth: microcirculation monitoring as a novel bioindicator. Implant Dent. 2015; 24(1):37-41. doi:10.1097/ID.0000000000000167. Bächle M, Butz F, Hübner U, Bakalinis E, Kohal RJ. Behavior of CAL72 osteoblast-like cells cultured on zirconia ceramics with different surface topographies. Clin Oral Implants Res. 2007;18(1):53-59. doi:10.1111/j.1600-0501.2006.01292.x. Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol. 2004;75(2):292-296. doi: 10.1902/jop.2004.75.2.292.

Transcript of CERAMIC DENTAL IMPLANT SOLUTIONS · IMPLANTS Powered by CeramTec MT-00624-2008-EN-01 CeramTec GmbH...

Page 1: CERAMIC DENTAL IMPLANT SOLUTIONS · IMPLANTS Powered by CeramTec MT-00624-2008-EN-01 CeramTec GmbH | Medical Products Division CeramTec-Platz 1–9 ... Kajiwara N, Masaki C, Mukaibo

CERAMIC DENTAL IMPLANTS

Powered by CeramTec

MT-

0062

4-20

08-E

N-0

1

CeramTec GmbH | Medical Products Division

CeramTec-Platz 1–9

D-73207 Plochingen

Mike Moynihan +49 7153 611 916

[email protected]

www.densilox.com

The depicted DENSILOX® implants as well as dental products made of ceramic foam are under development and are not approved by any authorities.

CERAMIC DENTAL IMPLANT SOLUTIONSThanks to the natural colouring and excellent biocompatibility of ceramic dental implants, more and more implantologists and patients show a preference for these materials.

Based on 45 years of development, manufacturing and testing of ceramic medical devices, CeramTec has become a trusted partner to develop your innovative ceramic implant solution.

1 StrongAll DENSILOX® ceramics demonstrate high hardness as well as high fracture strength and toughness.

2 Aesthetic You can choose DENSILOX® ceramics in a range of colours for an individual solution and for the highest aesthetic demand: natural white, ivory or ‘gingiva pink’.

3 Metal-free All DENSILOX® ceramic materials are 100% metal-free and demonstrate low biofilm adhesion.

ReferencesCeramTec Internal Data.

Cosgarea R, Gasparik C, Dudea D, Culic B, Dannewitz B, Sculean A. Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study. Clin Oral Implants Res. 2015;26(5):537-544. doi:10.1111/clr.12440.

de Medeiros RA, Vechiato-Filho AJ, Pellizzer EP, Mazaro JV, dos Santos DM, Goiato MC. Analysis of the peri-implant soft tissues in contact with zirconia abutments: an evidence-based literature review. J Contemp Dent Pract. 2013;14(3):567- 572. doi:10.5005/jp-journals-10024-1364.

Kajiwara N, Masaki C, Mukaibo T, Kondo Y, Nakamoto T, Hosokawa R. Soft tissue biological response to zirconia and metal implant abutments compared with natural tooth: microcirculation monitoring as a novel bioindicator. Implant Dent. 2015; 24(1):37-41. doi:10.1097/ID.0000000000000167.

Bächle M, Butz F, Hübner U, Bakalinis E, Kohal RJ. Behavior of CAL72 osteoblast-like cells cultured on zirconia ceramics with different surface topographies. Clin Oral Implants Res. 2007;18(1):53-59. doi:10.1111/j.1600-0501.2006.01292.x.

Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol. 2004;75(2):292-296. doi: 10.1902/jop.2004.75.2.292.