Emergency lighting
systems with central
power supply.
ONLITE central
ONLITE central LPSSelf-contained group battery system for maximum failure safety
ONLITE central CPSProject-specifi c customised, networked central battery system
No additional data cable required
Mixed operation (maintained mode and non-maintained mode) within one circuit
Simple commissioning
No external components required
Type-tested installations
Standard DALI monitoring
Adaptable circuit design – up to 300 circuits
Up to 6.000 emergency and escape sign luminaires are possible
Web browser-based visualisation
3
* LPS = Low Power Supply system (acc. to
EN 50171 Central power supply systems)
■ Limited output power
■ Comprises battery charger and charging
regulator, circuit outputs including battery
■ Type-tested installations
ONLITE central LPS *Self-contained group battery system for maximum failure safety
High level of safety
■ Entire system is split up into several
self-contained units■ Shorter cable lengths reduce fire loads
by up to 45 %■ Individual failure or error notification
5
Less effort on installationImpressive cost effectiveness
■ Communication based on Powerline
(mains cable)■ No fire-resistant cables required within
a fire compartment (not UK)■ 25 % less installation effort thanks to
subdivision of entire system
■ Flexibly programmable emergency lighting
levels allow lower battery capacities■ DALI compatibility ensures straightforward,
affordable integration into general lighting
system ■ Built-in staircase lighting function
ON
LIT
E c
en
tra
l LP
S
The ONLITE group battery system excels by combining maximum func-
tionality with seamless integration into the general lighting system. Sev-
eral self-contained systems ensure straightforward installation and quick
commissioning. ONLITE central LPS makes it possible to control and
monitor every luminaire individually. Emergency lighting is integrated into
the general lighting system and connection to the lighting management
system is obtained via DALI. The group batteries can be networked using
Ethernet in order to be able to control and monitor essential functions via
a graphical user interface.
Modular design for the most effective possible solution
Powder-coated
sheet-steel cabinet,
colour: RAL 7053
Ventilation slits for battery
ventilation and cooling
Inspection window
Terminal strip
EPS 360 Controller with
touch-sensitive panel
Battery compartment
partitioned off
from electronic system
Screwed cable glands
7
ONLITE central LPS system summary
LPS 360 LPS 720
* Limit values for group battery systems (LPS) according to
EN 50171:
Standby operating time 1 h: 1500 W
Standby operating time 3 h: 500 W
Four basic units delivering rated outputs from 360 W to 1440 W meet the
full range of group battery system requirements perfectly.
Circuits (each for up to 20 luminaires) 3 6
AC output power of each circuit (mains operation) 552 VA 552 VA
Mains connection 1 x 230 V
L/N/PE
2 x 400 V
L1/L2/N/PE
DC output power (emergency mode) 360 W* 720 W*
DC output power of each circuit (emergency mode) 120 W 120 W
Standby operating time 1 h 2 x 12 V 33 Ah 4 x 12 V 33 Ah
Standby operating time 3 h 2 x 12 V 75 Ah 4 x 12 V 75 Ah
9
LPS 1080 LPS 1440
9 12
552 VA 552 VA
3 x 400 V
L1/L2/L3/N/PE
3 x 400 V
L1/L2/L3/N/PE
1080 W* 1440 W*
120 W 120 W
6 x 12 V 33 Ah 8 x 12 V 33 Ah
6 x 12 V 75 Ah 8 x 12 V 75 Ah
NSI control gear with
built-in interface
ONLITE central LPS and
LED systems
www.zumtobel.com/onlite
Together, ONLITE central LPS and innovative LED emer-
gency and escape sign luminaires make a great team. Using
efficient LED luminaires which provide light distribution that
is perfectly matched to emergency lighting needs keeps the
installed load to a bare minimum. This means that required
battery capacities can be smaller and supply systems can
be significantly more compact. Communication between the
ONLITE central LPS system and the LED luminaires is based
on Powerline, which allows individual control and monitor-
ing of every luminaire. Emergency lighting can be operated
completely independently of the general lighting system.
Optimal solution for LED emergency lighting systems
3
11
ONLITE central LPS and
integrated LED emergency
lighting systems
www.zumtobel.com/ml
General lighting luminaires can be integrated into the emer-
gency lighting system in order to achieve a uniform ceil-
ing look. The ONLITE central LPS system ensures visual
matching and optimal functional integration into the gen-
eral lighting system. Every luminaire can be integrated into
a Zumtobel lighting management system via the ONLITE
central LPS system’s built-in DALI interface. Special LED
solutions can be integrated into the general lighting system
in order to improve the efficiency of emergency lighting and
reduce the required battery capacities. This combines the
advantages of separate emergency lighting luminaires and
the enhanced appearance of a consistent ceiling look. The
light sources for the general lighting system are powered
through the conventional wiring system, and the LEDs for
the emergency lighting system are powered by the ONLITE
central LPS system.
PCA
control gear
NSI emergency
lighting module
Mains cable
3
Monitoring, controlling and testing every group from a central location
Features of EPS 360■ Mains monitoring■ Control of power circuits and lumi-
naires■ Charging unit for batteries includ-
ing battery charging regulator■ Switchover device to change
from mains-powered operation to
emergency operation■ Transformer for emergency supply
from batteries■ Touch-sensitive screen for con-
trolling and configuring
Touch-sensitive screen
LED function display
Download the test log
book via infrared or RS
232 interface
3 output circuits
Up to 20 luminaires can be
connected to each of the
three output circuits of the
EPS 360 Controller. The
maximum permissible in-
stalled load per circuit is:
552 VA (mains operation)
and 120 W (emergency
operation).
The EPS 360 Controller is the core of every ONLITE central
LPS system. Depending on the size of the system, several
of these self-contained units are installed in order to ensure
maximum possible redundancy and hence optimum safety.
All settings and test logs are stored in non-volatile memory.
No data loss even in event of complete shutdown (mains
and battery power).
13
Programmable test cycles
The date and time of day of all function and service
life/annual system tests can be user programmed.
This prevents tests being performed at inoppor-
tune times, e. g. while a film is being shown in a
cinema.
Electronic test log book
All function and service life/annual system tests
are logged and stored in the electronic test log
book of the EPS 360 Controller for at least three
years. The test log book can be read out at any
time via an infrared or RS 232 interface.
Methods of connection
A wide variety of methods of connection guar-
antees maximum flexibility. Luminaires can be
switched individually or as a complete circuit. With
the individual method of connection, it is possible
to specify, for every individual luminaire, whether
it is to be set up in maintained mode, non-main-
tained mode or switched via any of the switching
inputs. In addition, every EPS 360 Controller has
a built-in automatic staircase lighting function.
Emergency lighting level at the push of a button The
emergency lighting level is set on the touch-sensitive display
of the EPS 360 Controller. These values, based on photo-
metric calculations, can be entered one circuit at a time or
for each individual luminaire. Zumtobel luminaires with DALI
dimmable ballasts (luminaire names starting with LDE) allow
individual definition of the dimming level in emergency op-
erating mode. The emergency luminous flux of emergency
luminaires can be reduced gradually down to 5 % of the
normal lighting.
Flexible illuminance levels Cut costs and reduce environmental impact
In the case of conventional emergency lighting solutions
with non-programmable emergency lighting levels, output in
emergency mode is identical to that in normal (mains opera-
tion) mode. This requires relatively high battery capacities
and results in higher energy consumption.
In most cases, 10 % of the lumen package of the mains
lighting is sufficient to guarantee minimum illuminance when
operating in emergency mode. The programmable emer-
gency lighting level minimises system costs because sets of
batteries and central installations can be designed consider-
ably smaller; this also helps reduce environmental impact.
Conventional solution
with non-programmable emergency lighting level
ONLITE central LPS solution
with programmable emergency lighting level
Lu
min
air
e 1
100 % 100 % 100 % 30 % 10 % 20 %
Lu
min
air
e 1
Lu
min
air
e 2
Lu
min
air
e 2
Lu
min
air
e 3
Lu
min
air
e 3
Circuit 1 120 W 13 x 11.5 W = 149.5 W (DC) = < 160 W
Circuit 2 120 W 10 x 11.5 W = 115.0 W (DC) = < 160 W
Circuit 3 120 W 11 x 8.0 W = 88.0 W (DC) = < 160 W
Total 360 W = 352.5 W (DC) = < 360 W
Output per controller:■ 360 W total emergency lighting output for
1 or 3 hours depending on battery set■ 3 output circuits, each for up to 20 luminaires■ Each output circuit rated 120 W in DC operation
and 552 VA in mains operation
The number of lighting points can be increased by
reducing the output of the luminaires
15
Light
source
Wattage AC power
[100 %]
230 V/50 Hz
[VA]
DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] Control gear / luminaire
Emergency
lighting level 5 % 10 % 15 % 20 % 30 % 40 % 50 % 60 % 70 % 100 %
LED 5.2 - - - - - - - - - 4.7 EM Power 1 LED NSI / ARTSIGN EW
LED 6.8 - - - - - - - - - 6.2 EM Power 1 LED NSI / ARTSIGN ED
LED 8.4 - - - - - - - - - 7.8 EM Power 2 LED NSI / PURESIGN AW
LED 11.8 - - - - - - - - - 11.2 EM Power 2 LED NSI / PURESIGN AD
LED 8.3 - - - - - - - - - 7.7 EM Power 1 LED NSI / COMSIGN II LED
LED 9.1 - 2.2 - - - - - - 6.5 8.5 EM Power 1 LED NSI / PROOFSIGN
LED 11.8 - - - - - - - - - 11.2 EM Power 2 LED NSI / SQUARESIGN 300
LED 11.8 - - - - - - - - - 11.2 EM Power 2 LED NSI / FREESIGN 300
LED 5.7 - - - - - - - - - 5.1 EM Power 1 LED NSI / RESCLITE
T16 14 W 17.3 7.3 8.0 8.6 8.9 10.1 11.7 12.4 14.0 14.5 14.7 PCA 1x14/24 T5 EXCEL one4all lp xitec
T16 2/14 W 32.7 11.4 12.7 14.6 15.3 17.9 21.3 23 26.4 27.7 28.0 PCA 2x14/24 T5 EXCEL one4all lp xitec
T16 21 W 24.8 7.1 8.3 9.7 10.3 12.2 14.8 16.2 18.8 20.0 20.3 PCA 1x21/39 T5 EXCEL one4all lp xitec
T16 2/21 W 47.0 12.3 14.3 16.9 18.2 22.2 27.1 29.9 35.2 37.8 38.3 PCA 2x21/39 T5 EXCEL one4all lp xitec
T16 28 W 31.9 7.7 9.2 11.0 12.0 14.7 18.1 20.2 23.7 25.4 25.8 PCA 1x28/54 T5 EXCEL one4all lp xitec
T16 2/28 W 63.1 13.7 16.3 19.7 21.5 26.7 33.2 37.1 43.9 47.3 48.0 PCA 2x28/54 T5 EXCEL one4all lp xitec
T16 35 W 39.8 8.5 11.1 13.3 14.4 17.6 21.8 24.3 28.6 30.7 31.2 PCA 1x35/49/80 T5 EXCEL one4all lp xitec
T16 2/35 W 77.4 14.5 18.0 22.2 24.6 31.3 39.4 44.5 52.7 56.9 57.7 PCA 2x35/49 T5 EXCEL one4all lp xitec
T16 24 W 26.8 8.5 9.6 11.1 11.7 13.8 16.8 18.6 21.3 22.4 22.6 PCA 1x14/24 T5 EXCEL one4all lp xitec
T16 2/24 W 53.1 13.9 16.2 19.2 20.7 25.6 31.5 35.0 41.1 44.0 44.7 PCA 2x14/24 T5 EXCEL one4all lp xitec
T16 39 W 43.3 9.3 11.3 13.8 15.2 19.3 23.9 26.7 31.8 34.5 35.0 PCA 1x21/39 T5 EXCEL one4all lp xitec
T16 2/39 W 85.1 16.4 20.3 25.2 28.1 35.9 45.8 52.1 61.8 66.7 67.8 PCA 2x21/39 T5 EXCEL one4all lp xitec
T16 49 W 54.7 10.7 13.1 16.1 17.9 22.7 28.5 32.2 38.3 41.4 42.0 PCA 1x35/49/80 T5 EXCEL one4all lp xitec
T16 2/49 W 106.6 17.2 22.2 28.1 31.8 41.7 53.4 60.9 73.3 80.1 81.5 PCA 2x35/49 T5 EXCEL one4all lp xitec
T16 54 W 61.0 11.8 14.6 18.1 20.3 25.8 32.6 36.9 44.0 47.7 48.5 PCA 1x28/54 T5 EXCEL one4all lp xitec
T16 2/54 W 119.4 21.1 26.9 33.9 38.3 49.6 63.1 71.8 85.4 92.5 94.0 PCA 2x28/54 T5 EXCEL one4all lp xitec
T16 80 W 87.9 14.7 18.8 23.8 27.0 35.3 45.2 51.6 61.7 67.0 68.0 PCA 1x35/49/80 T5 EXCEL one4all lp xitec
T26 1/18 W 26.0 8.5 9.5 10.5 12.0 13.0 13.5 16.5 PCA excel one4all
T26 2/18 W 43.0 16.0 17.5 19.0 23.0 25.0 26.5 28.0 PCA excel one4all
T26 1/30 W 34.0 9.5 11.5 13.0 15.5 18.5 20.5 25.0 PCA excel one4all
T26 2/30 W 61.0 16.0 19.0 22.0 28.0 32.5 37.5 45.5 PCA excel one4all
T26 1/36 W 42.0 12.5 15.0 16.5 20.0 22.0 24.5 28.5 PCA excel one4all
T26 2/36 W 74.0 22.5 26.5 30.5 36.0 40.0 43.5 53.5 PCA excel one4all
T26 1/58 W 61.0 17.5 21.0 24.5 29.0 33.5 37.5 45.5 PCA excel one4all
T26 2/58 W 110.0 31.5 37.5 44.5 53.5 60.5 67.5 83.5 PCA excel one4all
TC-L/F 1/18 W 24.0 6.0 6.5 7.5 8.5 9.5 10.5 12.5 PCA excel one4all
TC-L/F 2/18 W 41.0 9.0 10.5 12.0 14.0 16.5 18.5 23.5 PCA excel one4all
TC-L/F 1/24 W 31.0 9.0 11.0 12.5 15.0 17.0 19.0 22.5 PCA excel one4all
TC-L/F 2/24 W 53.0 14.5 17.5 20.5 25.5 30.5 34.5 42.5 PCA excel one4all
TC-L/F 1/36 W 39.0 12.0 14.5 16.5 20.5 24.0 26.5 32.5 PCA excel one4all
TC-L/F 2/36 W 73.0 18.5 22.5 27.0 33.5 40.0 46.0 59.5 PCA excel one4all
TC-L/F 1/40 W 50.0 14.5 17.5 20.5 23.5 26.5 29.5 36.5 PCA excel one4all
TC-L/F 2/40 W 90.0 26.5 31.0 35.5 44.5 51.5 57.5 72.5 PCA excel one4all
TC-L/F 1/55 W 63.0 16.5 23.0 29.5 28.5 34.5 39.5 52.5 PCA excel one4all
TC-L/F 2/55 W 121.0 30.5 38.5 46.5 58.0 67.5 76.5 101.5 PCA excel one4all
TC-S/E 1/11 W 19.0 6.5 7.5 8.0 9.5 10.5 11.5 13.0 PCA excel one4all
TC-S/E 2/11 W 33.0 9.5 11.5 13.0 12.5 13.5 14.5 24.0 PCA excel one4all
TC-D/E 1/13 W 20.0 6.5 8.0 8.5 10.0 11.0 12.0 14.0 PCA excel one4all
TC-D/E 2/13 W 33.0 10.0 12.0 13.5 16.0 19.0 21.5 26.0 PCA excel one4all
TC-D/T 1/18 W 24.0 7.0 8.5 9.5 11.5 13.5 15.0 18.0 PCA excel one4all
TC-D/T 2/18 W 43.0 13.0 15.5 17.5 21.5 24.5 27.5 34.0 PCA excel one4all
TC-D/T 1/26 W 33.0 10.0 12.0 13.5 16.5 18.5 20.5 24.5 PCA excel one4all
TC-D/T 2/26 W 57.0 16.5 20.5 23.5 29.5 34.0 38.5 46.5 PCA excel one4all
TC-T/E 1/32 W 36.0 10.5 13.5 15.5 19.5 22.5 25.5 30.5 PCA excel one4all
TC-T/E 2/32 W 66.0 17.5 22.5 27.0 34.5 41.5 48.0 59.5 PCA excel one4all
TC-T/E 1/42 W 47.0 12.0 15.0 17.5 22.5 27.5 31.0 39.5 PCA excel one4all
TC-T/E 2/42 W 88.0 23.5 29.0 34.5 43.5 52.0 59.5 77.5 PCA excel one4all
TC-DD 1/55 W 60.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PCA excel one4all
NV DSI 70 W 70.0 58.0 58.0 58.0 58.0 58.0 58.0 58.0 TEL 70 VA
NV DSI 105 W 105.0 85.0 85.0 85.0 85.0 85.0 85.0 85.0 TEL 105 VA
NV DSI 150 W 150.0 90.0 90.0 90.0 90.0 90.0 90.0 90.0 TEL 150 VA
NV DSI 210 W 210.0 137.0 137.0 137.0 137.0 137.0 137.0 137.0 TEL 210 VA
NV DALI 105 W 105.0 85.5 85.5 85.5 85.5 85.5 85.5 85.5 TEL one4all 105 VA
NV DALI 150 W 150.0 90.5 90.5 90.5 90.5 90.5 90.5 90.5 TEL one4all 150 VA
ONLITE central LPSSystem topology
LUXMATE bus
3 (L, N, PE)
L' switching conductor
L1, L2, N, PE
Emergency luminaire
switched (L’)
Mains-powered
luminaire
Mains-powered
luminaire
Escape sign luminaire
switched (L’)
Emergency luminaire
switched (L’)
Emergency luminaire
switched (L’)
Emergency luminaire
switched (L’)
3 (L, N, PE)
3 (L, N, PE)
FI
HVA UVA
ONLITE central EPDOrder no. 22 156 808
optional
DALI 2 x 1.5 mm2
DALI input is optional (if it is used, local and central switching is no longer possible)
ONLITE IR printerOrder no. 22 154 522
Infrared
LM-DALIS
LM-DALIS
N L3 L2 L1
1 4
17
EL1
EN
1P
EE
L2
EN
2P
EE
L3
EN
3P
ES
1S
3
El1
En1
PE
El2
En2
PE
El3
En3
PE
S1
S3
LS
LS
N N PE
K1
1K
12
K1
4K
21
K2
2K
24
K3
1K
32
K3
4
ONLITE central LPS 720 1h10Order no. 22 156 821
Battery cable Battery cable
ONLITE central EPDOrder no. 22 156 808
ONLITE central EPDOrder no. 22 156 808
UV2 UV3
ONLITE central Remote interface LPS/CPS
Order no. 22 154 740
Switching inputs, optional(only possible if there is no DALI input)
S2_
1
S3_
1
S2_
2
S3_
2
N S
4_
1
S5_
1
S5_
2
S4_
2
Indi
catio
n +
Indi
catio
n –
Emer
genc
y off
+
Emer
genc
y off
–
L'1
L'2
PH
W1 +
PH
W1 –
PH
W2 +
PH
W2 –
Syn
c +
Syn
c –
K1
Circuit 1
Circuit 2
Circuit 3
S1a S1b S1c
Ready for operation
Operation from battery
K2 K3 U+ U- S1 S2
L1L2L3N
PE
N L3 L2 L1
1 4
L1L2L3N
PE
N L3 L2 L1
1 4
Off
EPS 360 EPS 360
Notes:
■ Only ONLITE Powerline de vices and
the control gear to be controlled
may be connected to the EPS 360.
“External” consumers or interference
sources must not be connected to
the Powerline network.
■ Band-stop filters or filters are not
permitted in the Powerline domain.
■ Where the length of parallel cable
runs cannot be restricted to 10 m,
cables which are parallel must be
spaced at least 5 cm apart.
■ The maximum cable length is 300 m
(1.5 to 4 mm²).
Design tips
Individual monitoring of luminaires
Monitoring of circuits
With individual monitoring of luminaires, there is an intelligent
monitoring module inside every emergency luminaire which
communicates with the central emergency lighting power
source via Powerline. Every emergency luminaire is assigned
a unique luminaire address at the time of commissioning.
This makes it possible to display the status of each individual
emergency luminaire on the ONLITE central LPS.
An EPS 360 Controller which measures the power output
into its output circuit in order to ascertain whether all the
luminaires in the circuit are operating correctly is a distinc-
tive feature of this circuit monitoring. In the case of circuit
monitoring, only circuit-wide switching is possible.
Benefi ts
■ When an emergency luminaire fails, the location of
the faulty luminaire is pinpointed.
■ Emergency luminaires in one output circuit can be
individually configured to various modes of opera-
tion.
■ Emergency luminaires can be integrated into DALI
lighting control.
■ Emergency lighting levels can be programmed via
central emergency lighting power source.
Benefi ts
■ Luminaires do not have to be equipped with
add-on modules.
■ Any load suitable for AC/DC may be connected.
Disadvantage
■ It is not possible to pinpoint every individual lumi-
naire failure (depends on wattage mix of output
circuit and output of the luminaires).
Circuit 1
Circuit 2
Circuit 3Emergency power supply
Emergency power supply
Emergency power supply
Powerline
communication
ONLITE central LPS
Circuit 1
Circuit 2
Circuit 3Emergency power supply
Emergency power supply
Emergency power supply
ONLITE central LPS
Pcircuit
19
Integration into a lighting
management system
Central monitoring using
GO-ON package
The DALI interface ensures that emergency lighting can be
integrated seamlessly into general lighting. DALI commands
are converted to Powerline signals and are sent to the emer-
gency and escape sign luminaires. This way, every luminaire
can be individually controlled and included in automation
processes. LUXMATE lighting control systems make it pos-
sible to fully exploit a whole raft of advantages offered by
ONLITE central LPS.
Note: If DALI lighting control is enabled, the “central switch-
ing using switching inputs” and “local L' switching” functions
will no longer be available.
Note: ONLITE Central LPS version with Ethernet (Nport x)
must be used.
The ONLITE GO-ON package visualisation module provides
users with a convenient facility for monitoring their entire
ONLITE emergency lighting system from one central loca-
tion. Perfectly planned monitoring systems link up the group
or separate battery systems in one or more buildings into an
intelligent information network, which delivers information on
the status of the emergency lighting system round the clock.
230 V AC
230 V AC/DC
Emergency power supply
ONLITE central LPS
DALI
DALI
TCP/IP network
GO-ON
package
ONLITE central LPS
* CPS = Central Power Supply system
(acc. to EN 50171).
Can be used with no output limits
ONLITE central CPSProject-specific customised, networked central battery system
Less effort on design
■ Manageable, clearly structured product
range■ Integration into lighting management with
resulting significant technical and economic
benefits■ Project-specific solutions thanks to modular
system■ Full functionality as standard, renders ad-
ditional software and modules superfluous
21
Convenience at every levelPerfect design freedom
■ Simple, easily understandable operation
using removable Touch PC■ System information can be downloaded
via the Internet by using Web browser-
based software■ Function and annual system tests are run
and documented completely automati-
cally
■ Individual switching mode for each lumi-
naire, even within a single circuit■ Combination of monitoring of circuits and
individual luminaires in one system■ Simple project planning thanks to compe-
tent design support and extensive design
tools
ON
LIT
E c
en
tra
l C
PS
Every central battery system is designed project-specifically on the basis
of a modular system. This produces solutions which are optimised in
terms of the cost and functionality of the system. The modular design of
ONLITE central CPS guarantees a tailor-made solution for any project
and a significantly optimised cost/functionality ratio.
Tailor-made emergency lighting systemModular system for best possible price/performance ratio
Powder-coated sheet-steel cabinet,
colour: RAL 7053
Maximum energy efficiency thanks to■ Low-loss components■ Optimal battery capacity
Built-in Touch PC
Left-hand or right-hand door hinge
Detachable grating for safe transport using
lifting truck
Integral base with ventilation slits for battery
ventilation and cooling
Large wiring space for
convenient wiring
Disconnect terminals for all
connections
Modular cabinet design for
project-specific solutions
Generous battery compartment
with strong shelf supports for
simple connection and mainte-
nance of batteries
Integral collecting trough
eliminates need for electrolyte-
resistant floor surface
23
System designExamples of compact station and main station applications
CPS K
Compact station
Besides the internal controller and circuit modules, a battery with a
capacity of up to 75 Ah is accommodated in the main distribution unit of
the emergency lighting power supply. In addition, outgoing fuse protec-
tion for external sub-distribution boards of the emergency lighting system
can be catered for. It is preferable to use compact or combined stations
in medium-sized buildings.
UVS 2 UVS 7 UVS 8 UVS 3
UVS 1 UVS 1 UVS 2
E E
ES S
S S
7 Ah
12 Ah
17 Ah
24 Ah
28 Ah
33 Ah
45 Ah
55 Ah
75 Ah
7 Ah
12 Ah
17 Ah
24 Ah
28 Ah
33 Ah
45 Ah
55 Ah
75 Ah
Each internal or external substation (UVS)
can be selected to monitor circuits (S) or
individual luminaires (E).
25
CPS H
Main station
The main station contains the internal controller and, optionally, internal
circuit modules and outgoing circuits to the substations of the emergency
lighting system. Compared with the CPS K, batteries are accommodated
in external battery cabinets (output per cabinet up to 150 Ah; no more
than 2 cabinets) or on a battery rack. Main stations like these with a set
of external batteries are used in large buildings. Several self-contained
systems can be used where higher outputs are required (> 25–30 kW).
UVS 4 UVS 14 UVS 15
E
E
UVS 2
UVS 3
S
S S
UVS 1
S
Each internal or external substation (UVS)
can be selected to monitor circuits (S) or
individual luminaires (E).
ONLITE central CPS system overview
CPS K
Compact station
CPS H
Main station
Every ONLITE central CPS offers full functionality in order to comprehen-
sively meet the requirements placed on a central battery system using
as few components as possible. No additional software or modules are
needed. There is no need to fit any separate components in the luminaire
because every DALI luminaire can be used as an emergency luminaire
which can be individually monitored and controlled. This also reduces
effort on commissioning, inspecting and maintaining the system. A large
removable Touch PC is the core of the system. It enables, for example,
straightforward commissioning by one person or neatly laid out, easily-
manageable visualisation of the system’s status.
Features ■ Power in emergency mode from
1 to 30 kW■ Up to 300 circuits, each for
20 emergency luminaires■ Up to 12 external substations per
main station (CPS H)■ Mixed operation within one circuit is
possible■ Between 120 and 240 (optional)
freely assignable switching inputs■ Web browser-based user interface
Circuits (up to 20 luminaires) 1) Up to 40 internal + 20 external
2) Up to 20 internal + 140 external
Up to 60 internal + 240 external
Maximum number of luminaires 1) 1,200 pcs.
2) 3,200 pcs.
6,000 pcs.
Mains connection 5-pole 3 x 400 V 5-pole 3 x 400 V
Mains operation Total AC output power 7–30 kVA 30 kVA
Max. AC output power per circuit 1,300 VA 1,300 VA
AC output power per 20 circuits (per UVS) 4,700 VA 4,700 VA
Mains operation Total DC output power 7.6 kW [1 h]* 3.3 kW [3 h]* 22.7 kW [1 h]* 10 kW [3 h]*
Max. DC output power per circuit 1,300 W 1,300 W
DC output power per 20 circuits (per UVS) 4,700 W 4,700 W
Standby operating time 1 h–8 h 18 x 12 V / 7–75 Ah
accommodated in combined cabinet
18 x 12 V bis 200 Ah
accommodated in sep. battery cabinet or battery rack
* Including 25 % reserve capacity (battery ageing)
27
CPS U E30
Fire-resistant substation
CPS U E00
Substation
20 20
4,700 VA 4,700 VA
1,300 VA 1,300 VA
4,700 VA 4,700 VA
Control gear with built-in
DALI interface
ONLITE central CPS and
LED systems
www.zumtobel.com/onlite
Combining ONLITE central CPS with innovative LED emer-
gency and escape sign luminaires offers distinct advan-
tages. Using efficient LED luminaires that provide light
distribution which is perfectly matched to emergency light-
ing needs keeps the installed load to a bare minimum. This
means that required battery capacities can be smaller and
supply systems can be significantly more compact. Com-
munication between the CPS system and LED luminaires
is based on DALI and therefore supports individual control
and monitoring of every luminaire. Emergency lighting can
be operated completely independently of the general light-
ing system.
Every DALI standard luminaire is also an emergency luminaire
5
29
www.zumtobel.com/ecoos
PCA DALI
control gear
ONLITE central CPS and
general lighting system
Every DALI standard luminaire can be used as an emergency
luminaire which can be individually controlled and moni-
tored. No additional modules need to be fitted to achieve
this, and functionality of the general lighting system is com-
pletely preserved. This simplifies project planning, reduces
both costs and effort and makes choosing luminaires easy.
Delivery times for emergency luminaires are short because
they are luminaires in the standard product range.5
A system control centre for operating, displaying and networking
ONLITE central CPS sets new standards when it comes to monitoring
and display of emergency lighting systems. A 7" LED-backlit WVGA
widescreen (16:9) colour Touch PC displays the entire installation. Touch
and control: It takes no more than three touches to access individual
luminaire data and status displays. All events are recorded for at least
three years on a built-in SD card as a test log book.
Ethernet / WLAN / Internet
Networkability comes as standard
Every ONLITE central CPS module can be visu-
alised via Ethernet using a web-based browser
without the need for any additional software.
The system can therefore be managed remotely
from any PC.
31
Info
248.50 V
0.10 A
20.00 °C
24.11.201014:03:31
ONLITE CPS 7000Zumtobel
Ready for operation TestMains operation Unit malfunction Maintained lightMains failure UVA Luminaire failure System bus
Battery voltage
Charging current
Battery temperature
Info
24.11.201014:06:03
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
248.40 V
0.10 A
22.10 °C
UV summary Show all faulty lamps
Ready for operation TestMains operation Unit malfunction Maintained lightSystem bus
Info
24.11.201014:21:23
UV: UVS 15Line monitor:
Circuit 1: [Kal.: 0 W, Ist: 0 W]
Select
UV:
Circuits:
UVS 15
1 – 5U< U< U< U< U< U< U< U<
Circuit 2: [Kal.: 0 W, Ist: 29 W]
Circuit 3: [Kal.: 0 W, Ist: 0 W]
Circuit 4: [Kal.: 0 W, Ist: 0 W]
Circuit 5: [Kal.: 0 W, Ist: 0 W]
Luminaire status Faulty luminaires only
System status
Neatly laid out status display, includes system
voltage and battery temperature among other
parameters. Faults are displayed in plain lan-
guage and indicated visually.
Details of substations
Each of up to 7 substations can be displayed
on the central Touch PC. This simplifies the
job of the person tasked with maintenance
and helps them keep an overview of the entire
installation.
Details of luminaire status
Each individual luminaire is displayed at the
control centre. As well as visual error display,
further additional information is made avail-
able. The Touch PC provides details of the
location, light source type, wattage, method
of connection and address of every individual
luminaire.
Plug-in and networkPortable Touch PC for commissioning
Besides performing major system documentation and display tasks,
the removable unit with LED backlighting also offers substan-
tial benefits when commissioning the ONLITE central CPS system.
This operating and control unit plugs not only into the control centre
but also into every substation – for local commissioning, for example.
Every cabinet is equipped with a four-pole plug connector for this pur-
pose. Two conductors carry the 24 V power supply and two carry data.
The large number of ports is indicative
of the high quality of the unit’s internal
components: the Touch PC has no ro-
tating parts and is therefore extremely
rugged; the Windows CE Pro operating
system is pre-installed and it also has
an SD memory card with a storage
capacity of 512 MB.
A single cable is used for the 24 V sup-
ply voltage and the control bus.
33
All system information is available
anywhere on the network through Web
services. As well as querying the sys-
tem status, emergency luminaires can
also be visually addressed quickly and
easily. A combination of Powerline and
WLAN link provides the best possible
freedom of action. Using repeaters
eliminates the possibility of any gaps
in radio coverage. This “one-man”
commissioning saves both time and
money.
Luminaire addressing using
wireless network
Touch PCRouter (optional)
Line topology
900 m JY (St) Y 2 x 2 x 0.8 mm
Touch PC
Free topology
500 m JY (St) Y 2 x 2 x 0.8 mm
Touch PC
Total system control (bus line) cable
lengths of 500 m can be realised using
the standard “free topology” version.
Up to 320 m between any nodes.
The length of the system control cable
can be increased to as much as 900 m
by locating terminating resistors ( )
correctly.
Monitoring of circuits
Types of monitoring
Individual monitoring of luminaires
Monitoring of circuits
using LUXMATE LITENET
Circuit monitoring is used primarily in extensive buildings
which have consistent lighting concepts. Industrial factory
buildings and parking garages are typical examples of such
buildings. Even a circuit error of 10 % can be localised in final
circuits which incorporate luminaires of similar wattages.
Individual monitoring is preferred in buildings such as shop-
ping malls, hospitals or museums where there are a variety
of lighting systems. Addressable, switchable and dimmable
standard luminaires with DALI ballasts are used. Here too, it
is possible to set the desired emergency power level without
any additional components. Besides conventional DC emer-
gency operation, the built-in security function also trips in AC
emergency mode. This guarantees consistent functionality,
even if the control cable is interrupted or short-circuited.
Using LUXMATE LITNET, the leading lighting system which
is used in large office buildings in particular, allows the user
to dispense with a large proportion of ONLITE central CPS
hardware and software for luminaire monitoring. A system
with circuit monitoring is sufficient; individual monitoring
of luminaires is taken care of by LITENET. This way, every
emergency luminaire need only be addressed once at the
time of commissioning.
■ Straightforward design and commissioning ■ Use of standard luminaires with electronic ballasts ■ Lower investment costs but restricted functionality
■ Maximum safety ■ Lower operating costs ■ Maximum functionality
■ Maximum convenience and flexibility■ Many ONLITE central CPS functions are already incor-
porated in the LUXMATE LITENET lighting management
system■ Easy commissioning
35
Variable monitoring Anything is possible: circuit, individual luminaires or a combination of both systems
Monitoring of circuits or monitoring of indi-
vidual luminaires may be useful, depending
on the particular application. ONLITE central
CPS caters for specific circumstances, every
station can be designed with both methods of
connection. The modular system design even
makes it possible to mix modules with circuit
monitoring and modules with individual moni-
toring of luminaires within one installation. One
to three bays are available for monitoring mod-
ules depending on the design of the relevant
distribution cabinet. These bays can either be
fitted with modules for circuit-wide monitoring
or individual monitoring of luminaires. Every
module can handle 1 to 20 circuits.
CPS U E00
The sub-distribution board can be
equipped either for circuit moni-
toring or individual monitoring of
luminaires.
S E
Module for Module for
circuit individual
monitoring monitoring of
luminaires
Circuits 0–20 0–20
Number of luminaires 0–400 0–400
Max. power (W) 4700 4700
Max. power per circuit (W) 1300 1300
Fuse per circuit (A) 10 10
Outgoing terminals (mm²) 4 4
Digital potential-free inputs 8–16 8–16
CPS U E30
The sub-distribution board can be
equipped either for circuit moni-
toring or individual monitoring of
luminaires.
CPS H
600 mm
Each of the two bays sections can
be fitted with a sub-distribution
board for circuit monitoring or in-
dividual monitoring of luminaires.
CPS K
Each of the two bays can be fitted
with a module for circuit monitor-
ing or individual monitoring of
luminaires.
CPS H
850 mm
Each of the three bays can be fit-
ted with a sub-distribution board
for circuit monitoring or individual
monitoring of luminaires.
37
Example
Circuit monitored
S
Example
Individual luminaires monitored
E
Example
Circuit monitored
Example
Combination
SS ES
Example
Individual luminaires monitored
Example
Combination
E E ES
Example
Circuit monitored
Example
Combination
S S
S
S E
E
High-performance batteriesLarge choice of powerful block batteries
According to EN 50 272 specifi cations, reliable OGiV block
batteries are required for stationary applications. Sealed,
rechargeable batteries with a high discharge rate, these bat-
teries are built to the very latest standards. With a design life
of over 10 years at 20 °C, they meet EUROBAT requirements
for batteries classified as “high performance”. The accessories
required for battery installation are supplied.
12
Service life
(years)
Ambient temperature
(°C)
10
8
6
4
2
5020 25 30 35 40 45
EUROBAT “high per-
formance” class with
design life of more than
10 years at 20 °C
39
■ Grid-type plates with high discharge rate (lead-calcium)■ Absorptive glass mat technology■ Capacity from 7 to 200 Ah in 12 V blocks■ Housing and lid made of ABS■ Recessed battery terminals with brass core, internally
screwable■ Conforms to DIN EN 60896-21:2004■ Extremely low gassing■ Low self discharge■ 100 % recyclable■ Not classed as dangerous goods for transport by road,
rail, air or inland waterway■ Maintenance free
Battery temperature must be maintained
between +5 °C min. and +30 °C max. in
order to obtain full battery performance. A
nominal temperature of 20 °C is ideal. The
temperature difference between cells or
blocks in a battery bank must not exceed
5 °C.
An electrolyte-resistant floor surface in
the room where batteries are installed and
acid-resistant troughs in cabinets can be
dispensed with because leakproof batter-
ies according to DIN EN 50272-2:2001 are
used.
Notes on battery planning and installation
Battery selection table
Technical data
Trickle-charge voltage: 2.3 V/cell
Temperature compensation: ± 20 mV / 1 °C
Battery type Battery
block-voltage
[V]
Capacity (Ah)
25 °C, 1.8 V / Zelle
8 h 3 h 1 h
Dimensions
L x B x H [mm]
Weight
[kg]
Terminal
connection
12-7.2 12 6.7 5.3 4.8 151 x 65 x 94 2.5 Faston
12-12 12 11.5 9.0 8.2 151 x 65 x 95 3.9 Faston
12-17 12 16.4 15.6 13.8 181 x 77 x 167 5.9 M5
12-24 12 23.2 21.7 17.4 166 x 175 x 125 9.0 M5
12-28 12 27.3 24.9 20.9 165 x 125 x 175 9.7 M5
12-33 12 32.0 27.7 22.9 195 x 130 x 168 11.7 M6
12-45 12 42.9 36.3 29.0 197 x 165 x 170 14.8 M6
12-55 12 54.1 47.0 38.7 229 x 138 x 208 18.0 M6
12-75 12 70.3 57.9 46.2 258 x 166 x 215 24.0 M6
12-80 12 76.9 65.1 53.9 350 x 167 x 179 26.2 M6
12-90 12 86.7 72.6 60.5 306 x 169 x 214 30.0 M6
12-100 12 98.2 86.1 70.0 330 x 171 x 222 33.0 M6
12-120 12 118.1 104.5 81.5 410 x 176 x 277 37.7 M8
12-134 12 138.0 123.6 100.9 341 x 173 x 283 44.8 M8
12-150 12 146.1 124.9 130.0 485 x 172 x 240 46.4 M8
12-190 12 175.0 124.0 130.0 522 x 238 x 223 64.8 M8
12-200 12 198.1 175.3 143.7 522 x 238 x 223 67.0 M8
info
?
<
>
ONLITE central
Touch PC
SC U+ U-K1 K2 K3 GND 24V A BS1
24V
0V
2 x
5
L1
L2
L3 N PE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
–2x4S
3S
2
S4
S5
S6
S7
A1 +
A1 –
PE
A2 + +
-
A2 –
Ax +
Ax –
3 3
–
+
32
–2x1
=~
JY
(S
t) Y
2 x
2 x
0.8
ONLITE central CPS System topology
HVA
HVS
LE loading unit
Emergency-off
By pressing the emergency-off
button, the complete ONLITE
central CPS system (including
all substations) is disconnected
from power supply. This ensures
that emergency forces can safely
do their job. The internal +24 V
supply is carried via an NC switch
(emergency-off) and connected
to the S5 terminal (2 x 1 terminal
strip at the main station), while
the configuration is adjusted to
the emergency-off function using
the Touch PC.
ONLITE central
Remote Interface LPS/CPS
Order no. 22 154 740
Te
mp
era
ture
se
nso
r
Fa
n f
au
lt in
dic
ati
on
to U
VS
1
to U
VS
2
Ma
ins f
rom
HV
A
Battery
216 V
Po
we
r su
pp
ly b
us 2
4 V
Bloc
king
the
sys
tem
Read
ines
s fo
r se
rvic
e
Ope
ratio
n fr
om b
atte
ry
Cent
ralis
ed f
ault
41
NW1
L1
L2
L3
N
PE
N L3 L2 L1
1 4FINW2
L1
L2
L3
N
PE
N L3 L2 L1
1 4FI+
-
+
-
AD
12
PE
1 2 3 4 5 6 7 8 910
11
12
13
14
15
16
17
18
19
20
AD
12
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
AD
12
AD
12
AD
12
AD
12
AD
12
AD
12
AD
12
AD
12
BD
12
12
BD
12
12
BD
12
12
BD
12
12
BD
12
12
CD
12
12
CD
12
12
CD
12
12
CD
12
12
CD
12
12
DD
12
12
DD
12
12
DD
12
12
DD
12
12
DD
12
12
5x1
3 32
B1+
B1–
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
S1
S2
S8
[...]
5x1
B1+
B1–
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
S1
S2
S8
[...]
E30
JY
(S
t) Y
2 x
2 x
0.8
JY
(S
t) Y
2 x
2 x
0.8
4x2
4x3
5x2
5x3
UVA 1 UVA 2
UVS
circuit monitoring
UVS
individual
monitoring
To next UV
Syste
m b
us
Syste
m b
us
Emergency lighting as an isolated solutionDesign tips
Regardless of circuit monitoring or individual monitoring of luminaires,
individual emergency and escape sign luminaires are switched by po-
tential-free inputs or permanently used as maintained or non-maintained
luminaires. Built-in functions such as staircase lighting or switching by
variable timers are available.
digital in
DALI
fire-p
roof cab
ling
Data
CPS-U
E30
Individually monitored
E
ES
DALI
Individually monitored
Mains-
emergency
Circuit monitored
8 –16 digital in
Phase detector loop
CPS-K
7 Ah
to
75 Ah
43
Potential-free inputs Every ONLITE central CPS main station and sub-
station provides eight digital potential-free inputs as standard. The first
input (S1) is designed as a critical circuit and, as a rule, is used for the
phase detector loop. Several phase detector loops or other potential-free
switching inputs can be parameterised. Each of the switching inputs is
connected to the internal 24 V reference potential. Eight other potential-
free inputs are optionally available for each ONLITE central CPS station.
UV1
+ 24 V
1
2
8
9 – 16 potential-free digital inputs
Phase detector loop
Optionally: 8 additional expansion inputs
Mains L´ for external switching inputs
L1L2L3N
PE
N L3 L2 L1
1 4
UVA 1
FI
Mains L´ for external switching inputs
Emergency lighting with LUXMATE LITENETDesign tips
This system topology is based on an ONLITE central CPS with circuit-
monitored modules (S). All luminaires (general and emergency luminaires)
are metallically separated from one or more common DALI chains and
networked to the LAN hardware (Ethernet, TCP/IP) via the LITENET
netlink. All status in formation is available via the LUXMATE LITENET
network. The ONLITE central CPS operates completely independently,
and autonomously forwards messages concerning battery and charger
to LUXMATE LITENET via the Ethernet network.
www.zumtobel.com/litenet
S
S
S
CPS-BS
33 Ah45 Ah55 Ah75 Ah80 Ah90 Ah
100 Ah120 Ah134 Ah150 Ah
LAN
TC
P/IP
Data
8 –16 digital in
Phase detector loop
Temperature sensor
CPS-H
CPS-U E30
Individually monitored (DALI) combined
with LUXMATE LITENET
to UVA (L/N)
to UVA (L/N)
DALILITENET netlink
DALILITENET netlink
fire-
proo
f ca
blin
g
fire-proof cabling
45
LITENET netlink
Ethernet TCP/IP
DALI
UV1
L1L2L3N
PE
N L3 L2 L1
1 3
UVA 1
FI
Phase detector also monitors A standard built-in phase detector
monitors the general power supply system. If this power supply fails,
the DALI circuit in question is short-circuited. All DALI emergency and
escape sign luminaires change to system-failure level and immedi-
ately switch to the configured value. This security function is exe-
cuted without communicating with the emergency luminaires.
System project planningStep-by-step guide to the perfect lighting solution
Do photometric calculations for escape routes
Defi ne percentage Ballast Lumen Factor (BLF) as basis
for output of each emergency luminaire
Plan the locations of escape sign luminaires
Defi ne the circuits in each fi re compartment
Add up power output (PAC and PDC) of all emergency
and escape sign luminaires for each output circuit
Determine battery capacity depending on duration
of battery-powered operation
The entire design process is broken down into individual
design steps in order to ensure a target-oriented approach
when designing emergency lighting. This is a tried-and-
tested strategy for arriving at the optimum solution.
47
A Light
source
Wattage AC power
[100 %]
230 V/50 Hz
[VA]
DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] DC [W] Control gear / luminaire
Emergency
lighting level 5 % 10 % 15 % 20 % 30 % 40 % 50 % 60 % 70 % 100 %
LED 5.2 - 1.7 - - - - - - 3.5 4.8 EM Power 1 LED DALI / ARTSIGN EW
LED 6.6 - 3.2 - - - - - - 5.0 6.3 EM Power 1 LED DALI / ARTSIGN ED
LED 8.1 - 2.4 - - - - - - 5.0 7.7 EM Power 2 LED DALI / PURESIGN AW
LED 11.1 - 2.8 - - - - - - 8.1 10.8 EM Power 2 LED DALI / PURESIGN AD
LED 8.1 - - - - - - - - - 7.7 EM Power 1 LED DALI / COMSIGN II LED
LED 8.8 - - - - - - - - - 8.5 EM Power 1 LED DALI / PROOFSIGN
LED 11.1 - 2.8 - - - - - - 8.1 10.8 EM Power 2 LED DALI / SQUARESIGN
LED 11.1 - 2.8 - - - - - - 8.1 10.8 EM Power 2 LED DALI / FREESIGN
LED 5.4 - - - - - - - - - 5.0 EM Power 1 LED DALI / RESCLITE
T16 14 W 16.3 6.8 7.5 8.1 8.4 9.6 11.0 11.9 13.2 14.0 14.2 PCA 1x14/24 T5 EXCEL one4all lp xitec
T16 2/14 W 31.7 10.9 12.2 13.8 14.8 17.4 20.3 22.5 25.3 27.2 27.5 PCA 2x14/24 T5 EXCEL one4all lp xitec
T16 21 W 23.8 6.6 7.8 9.0 9.8 11.7 14.0 15.7 18.0 19.5 19.8 PCA 1x21/39 T5 EXCEL one4all lp xitec
T16 2/21W 46.0 11.8 13.8 16.1 17.7 21.7 26.1 29.4 34.0 37.3 37.8 PCA 2x21/39 T5 EXCEL one4all lp xitec
T16 28 W 30.9 7.2 8.7 10.3 11.5 14.2 17.3 19.7 22.7 24.9 25.3 PCA 1x28/54 T5 EXCEL one4all lp xitec
T16 2/28 W 62.1 13.2 15.8 18.8 21.0 26.2 32.0 36.6 42.5 46.8 47.5 PCA 2x28/54 T5 EXCEL one4all lp xitec
T16 35 W 38.8 8.0 10.6 12.5 13.9 17.1 20.9 23.8 27.5 30.2 30.7 PCA 1x35/49/80 T5 EXCEL one4all lp xitec
T16 2/35 W 76.4 14.0 17.5 21.2 24.1 30.8 38.1 44.0 51.2 56.4 57.2 PCA 2x35/49 T5 EXCEL one4all lp xitec
T16 24 W 25.8 8.0 9.1 10.4 11.2 13.3 16.0 18.1 20.4 21.9 22.1 PCA 1x14/24 T5 EXCEL one4all lp xitec
T16 2/24 W 52.1 13.4 15.7 18.3 20.2 25.1 30.4 34.5 39.8 43.5 44.2 PCA 2x14/24 T5 EXCEL one4all lp xitec
T16 39 W 42.3 8.8 10.8 13.0 14.7 18.8 23.0 26.2 30.7 34.0 34.5 PCA 1x21/39 T5 EXCEL one4all lp xitec
T16 2/39 W 84.1 15.9 19.8 24.2 27.6 35.4 44.4 51.6 60.1 66.2 67.3 PCA 2x21/39 T5 EXCEL one4all lp xitec
T16 49 W 53.7 10.2 12.6 15.3 17.4 22.2 27.5 31.7 37.0 40.9 41.5 PCA 1x35/49/80 T5 EXCEL one4all lp xitec
T16 2/49 W 105.6 16.7 21.7 27.0 31.3 41.2 51.8 60.4 71.4 79.6 81.0 PCA 2x35/49 T5 EXCEL one4all lp xitec
T16 54 W 60.0 11.3 14.1 17.3 19.8 25.3 31.5 36.4 42.6 47.2 48.0 PCA 1x28/54 T5 EXCEL one4all lp xitec
T16 2/54 W 118.4 20.6 26.4 32.7 37.8 49.1 61.4 71.3 83.3 92.0 93.5 PCA 2x28/54 T5 EXCEL one4all lp xitec
T16 80 W 86.9 14.2 18.3 22.8 26.5 34.8 43.8 51.1 60.0 66.5 67.5 PCA 1x35/49/80 T5 EXCEL one4all lp xitec
T26 1/18 W 26.0 8.5 9.5 10.5 12.0 13.0 13.5 16.5 PCA excel one4all
T26 2/18 W 43.0 16.0 17.5 19.0 23.0 25.0 26.5 28.0 PCA excel one4all
T26 1/30 W 34.0 9.5 11.5 13.0 15.5 18.5 20.5 25.0 PCA excel one4all
T26 2/30 W 61.0 16.0 19.0 22.0 28.0 32.5 37.5 45.5 PCA excel one4all
T26 1/36 W 42.0 12.5 15.0 16.5 20.0 22.0 24.5 28.5 PCA excel one4all
T26 2/36 W 74.0 22.5 26.5 30.5 36.0 40.0 43.5 53.5 PCA excel one4all
T26 1/58 W 61.0 17.5 21.0 24.5 29.0 33.5 37.5 45.5 PCA excel one4all
T26 2/58 W 110.0 31.5 37.5 44.5 53.5 60.5 67.5 83.5 PCA excel one4all
TC-L/F 1/18 W 24.0 6.0 6.5 7.5 8.5 9.5 10.5 12.5 PCA excel one4all
TC-L/F 2/18 W 41.0 9.0 10.5 12.0 14.0 16.5 18.5 23.5 PCA excel one4all
TC-L/F 1/24 W 31.0 9.0 11.0 12.5 15.0 17.0 19.0 22.5 PCA excel one4all
TC-L/F 2/24 W 53.0 14.5 17.5 20.5 25.5 30.5 34.5 42.5 PCA excel one4all
TC-L/F 1/36 W 39.0 12.0 14.5 16.5 20.5 24.0 26.5 32.5 PCA excel one4all
TC-L/F 2/36 W 73.0 18.5 22.5 27.0 33.5 40.0 46.0 59.5 PCA excel one4all
TC-L/F 1/40 W 50.0 14.5 17.5 20.5 23.5 26.5 29.5 36.5 PCA excel one4all
TC-L/F 2/40 W 90.0 26.5 31.0 35.5 44.5 51.5 57.5 72.5 PCA excel one4all
TC-L/F 1/55 W 63.0 16.5 23.0 29.5 28.5 34.5 39.5 52.5 PCA excel one4all
TC-L/F 2/55 W 121.0 30.5 38.5 46.5 58.0 67.5 76.5 101.5 PCA excel one4all
TC-S/E 1/11 W 19.0 6.5 7.5 8.0 9.5 10.5 11.5 13.0 PCA excel one4all
TC-S/E 2/11 W 33.0 9.5 11.5 13.0 12.5 13.5 14.5 24.0 PCA excel one4all
TC-D/E 1/13 W 20.0 6.5 8.0 8.5 10.0 11.0 12.0 14.0 PCA excel one4all
TC-D/E 2/13 W 33.0 10.0 12.0 13.5 16.0 19.0 21.5 26.0 PCA excel one4all
TC-D/T 1/18 W 24.0 7.0 8.5 9.5 11.5 13.5 15.0 18.0 PCA excel one4all
TC-D/T 2/18 W 43.0 13.0 15.5 17.5 21.5 24.5 27.5 34.0 PCA excel one4all
TC-D/T 1/26 W 33.0 10.0 12.0 13.5 16.5 18.5 20.5 24.5 PCA excel one4all
TC-D/T 2/26 W 57.0 16.5 20.5 23.5 29.5 34.0 38.5 46.5 PCA excel one4all
TC-T/E 1/32 W 36.0 10.5 13.5 15.5 19.5 22.5 25.5 30.5 PCA excel one4all
TC-T/E 2/32 W 66.0 17.5 22.5 27.0 34.5 41.5 48.0 59.5 PCA excel one4all
TC-T/E 1/42 W 47.0 12.0 15.0 17.5 22.5 27.5 31.0 39.5 PCA excel one4all
TC-T/E 2/42 W 88.0 23.5 29.0 34.5 43.5 52.0 59.5 77.5 PCA excel one4all
TC-DD 1/55 W 60.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PCA excel one4all
NV DSI 70 W 70.0 58.0 58.0 58.0 58.0 58.0 58.0 58.0 TEL 70 VA
NV DSI 105 W 105.0 85.0 85.0 85.0 85.0 85.0 85.0 85.0 TEL 105 VA
NV DSI 150 W 150.0 90.0 90.0 90.0 90.0 90.0 90.0 90.0 TEL 150 VA
NV DSI 210 W 210.0 137.0 137.0 137.0 137.0 137.0 137.0 137.0 TEL 210 VA
NV DALI 105 W 105.0 85.5 85.5 85.5 85.5 85.5 85.5 85.5 TEL one4all 105 VA
NV DALI 150 W 150.0 90.5 90.5 90.5 90.5 90.5 90.5 90.5 TEL one4all 150 VA
Ballast/lumen factor table
Specify battery size (OGiV block batteries) For optimum battery dimensioning, add 25 % reserve capacity to these values
(EN 50171 - 6.12.4).B
Battery set
DC output in W
Battery power
25 °C, 1.8 V per cell
7 Ah 12 Ah 17 Ah 24 Ah 28 Ah 33 Ah 45 Ah 55 Ah 75 Ah 80 Ah 90 Ah 100 Ah 120 Ah 150 Ah 190 Ah 200 Ah
216 V system 1 h 864 1.685 2.786 3.618 4.417 4.752 5.886 7.765 9.558 10.778 12.312 14.256 17.064 21.384 24.840 28.404
216 V system 3 h 454 662 1.075 1.415 1.782 2.030 2.549 3.262 4.180 4.644 5.119 6.145 7.171 8.888 10.638 12.528
216 V system 8 h 170 292 430 606 761 875 1.166 1.469 2.009 2.171 2.387 2.754 3.316 4.158 4.730 5.573
Survey ventilation conditions Data for ventilation of battery rooms according to EN 50272-2.
Battery capacity
C10 at 1.8 V per cell
7 Ah 12 Ah 17 Ah 24 Ah 28 Ah 33 Ah 45 Ah 55 Ah 75 Ah 80 Ah 90 Ah 100 Ah 120 Ah 134 Ah 150 Ah 190 Ah 200 Ah
Required air volume fl ow
rate in case of artifi cial
ventilation [m³/h]
0.04 0.07 0.73 1.04 1.21 1.43 1.94 2.38 3.24 3.64 3.89 4.32 5.18 5.79 6.48 8.21 8.64
Cross-sectional area of
ventilation openings with
natural ventilation [cm²]
1.06 1.81 20.44 29.12 33.88 40.04 54.32 66.64 90.72 96.88 108.92 120.96 145.04 162.12 181.44 229.88 241.92
C
This table shows the maximum power requirements of a
system. To provide for the permissible voltage drop of cable
dimensioning and to protect the system, the total installed
load actually calculated must be used.
Power requirements of CPS system
Total connected load [VA]
7,000 14,000 21,000 30,000
Fuse protection
Switch-disconnector-fuse [A]
80
Single phase
80
Two phase
80
Three phase
100
Three phase
D
Where possible, choose a standard Cu cross-section of
1.5 mm² in order to obtain optimum expansion.
* Free topology is recommended, system bus need not be
adapted for this (see page 33).
DALI cable lengths
System bus cable lengths
DALI control circuit cable length [m]
300 200 150 100
Recommended Cu cross-section
with standard wiring [mm²] 1.5 1.0 0.8 0.5
DATA bus cable length [m]
500 (standard equipment) 900
Line topology JY (St) Y 2 x 2 x 0.8 mm
Free topology * JY (St) Y 2 x 2 x 0.8 mm
Dimension cable appropriately depending on distance and
connecting cable to ensure permissible voltage drop.
* Depending on cable length
Indication = minimum cross-section
Power requirements of ONLITE central substation (E00/E30)
Total installed load [VA]
1,000 2,000 3,000 3,500 4,000 4,300
Fuse protection,
Neozed fuse [A] 16 16 20 20 25 25
Calculation for 50 m
cable length * [mm²] 4 10 10 16 16 16
Calculation for 100 m
cable length * [mm²] 6 16 25 25 35 35
E
Circuits are protected by 6.3 A fuses suitable for DC on
both poles. 3 A, 15 A or 10 A fuses can be used for specific
projects.
ONLITE central CPS outgoing circuits
Output power [W]
435 870 (standard equipment) 1380
Fuse protection
Outgoing circuit [A] 3.15 6.30 10.00
Max. current carrying capacity [A] 1.90 3.80 6.00
F
G
H
DALI
Data
Data
CPS-U
E30
CPS-K
DALI
E
CPS-U
E30
DALI
E
E GDALI cable lengths
Power and fuse protection
Individual monitoring
Individual monitoring
Individual monitoring
EConnected loads
ABallast lumen factor
AC/DC power
See page 36/37 for
module versions
Battery selection
B
D Power and fuse protection
COutlet air and
volume of air
F
CInlet air and volume of air
System bus cable lengths
H
fire
-pro
of
ca
blin
g
fire-proof cabling
www.zumtobel.com/onlite
ONLITE central LPS
Self-contained group
battery system for excellent
failure safety.
The ONLITE group battery sys-tem excels by combining maxi-mum functionality with seamless integration into the general light-ing system. Several self-con-tained systems ensure straight-forward installation and quick commissioning.
Characteristics– Four basic sizes: power in
emergency mode 360, 720, 1080 or 1440 W
– 3 to 12 circuits, each for 20 luminaires
– Monitoring of individual lumi-naires and circuit monitoring
– Mixed operation within one cir-cuit is possible
– Individually adjustable emer-gency power level for every luminaire
Benefits– Straightforward ordering from
catalogue thanks to standard-ised basic sizes
– Extremely simple installation without E30 fire-resistant cables within fire compartment (not UK)
– Highly flexible in the event of changes and extensions
– Optimised battery capacities reduce both costs and envi-ronmental pollution
– Easy connection to lighting management system
ONLITE central LPS
ON
LIT
E P
rod
uc
t C
ata
log
ue
51
System application ONLITE CENTRAL
PLC-Relais
PLC-Interface
Circuit 1
TECTON
PLC-Interface TECTON
Energy-saving lamp
Escape sign luminaire
Momentary-action switch L’
L1 Circuit 2
Circuit 3
Connection to lighting management systemSwitch inputs S1/S2/S3 and L‘- function are not available in case of connection to lighting management system!
Staircase lighting func-tion
Sub-distribution board
EPS 360
EPD
Switch inputs are only available if connection to lighting management system is not activated!
Momentary-action switch L’
Limit values for group battery systems according to EN50171:Output power:Standby operating time 1 h: 1,500 WStandby operating time 3 h: 500 W
Supplied with OGiV block batteries required for stationary applications according to EN50272. The sealed, rechargeable bat-teries with a high discharge rate are built to the very latest standards. With a design life of 10 years at 20 °C they meet EUROBAT requirements for batteries classified as “high performance”.
ONLITE CENTRAL LPS 360
■ Central supply and monitoring of emergency and escape sign lumi-naires/version central
■ Individual monitoring of luminaires ■ Backlit touch panel for control/pro-
gramming and visualisation ■ Test log book function > 3 years ■ 3 output circuits each for a max. of
20 luminaires ■ Power line communication to lumi-
naires ■ Housing sheet-steel cabinet incl. bat-
tery compartment ■ All cable outputs have been prewired
on a terminal strip ■ Charging unit for lead-gel batteries
incl. temperature display ■ Set of batteries included in the supply ■ Incl. interface box ■ Voltage: 230 V ±10 %, frequency:
50/60 Hz Output voltage: 230 V AC (mains operation), 230 V DC (emer-gency operation)
■ ONLITE Central LPS 360: Max. installed load: 1.7 kVA (at full load), output power of circuits: circuit 1–3: 550 VA AC (4AT) each, max. 120 W DC
kg Order no.
ONLITE central LPS 360 360 W 1 h 10 JB 32 Ah 2 x 12 V Housing model: 02 48.0 22 156 815
360 W 3 h 10 JB 61 Ah 2 x 12 V Housing model: 03 89.0 22 156 817
ONLITE central LPS 360 Nport2 Ethernet version 360 W 1 h 10 JB 32 Ah 2 x 12 V Housing model: 02 48.0 22 154 543
360 W 3 h 10 JB 61 Ah 2 x 12 V Housing model: 03 89.0 22 154 544
500
800
420
720
125°
Typ 2
Ø 9 mm202
600
1000
520
920
125°
Typ 3
Ø 9 mm202
ONLITE central LPS
ONLITE CENTRAL LPS 720 / 1080 / 1440
■ Central supply and monitoring of emergency and escape sign lumi-naires/version central
■ Individual monitoring of luminaires ■ Backlit touch panel for control/pro-
gramming and visualisation ■ Test log book function > 3 years ■ 3 output circuits each for a max. of
20 luminaires ■ Power line communication to lumi-
naires ■ Housing sheet-steel cabinet incl. bat-
tery compartment ■ All cable outputs have been prewired
on a terminal strip ■ Charging unit for lead-gel batteries
incl. temperature display ■ Set of batteries included in the supply ■ Incl. interface box ■ Voltage: 230 V ±10 %, frequency:
50/60 Hz Output voltage: 230 V AC (mains operation), 230 V DC (emer-gency operation)
■ ONLITE Central LPS 720: Max. installed load: 3.4 kVA (at full load), output power of circuits: circuit 1–6: 550 VA AC (4AT) each, max. 120 W DC
■ ONLITE Central LPS 1080: Max. installed load: 5.0 kVA (at full load), output power of circuits: circuit 1–9: 550 VA AC (4AT) each, max. 120 W DC
■ ONLITE Central LPS 1440: Max. installed load: 6.7 kVA (at full load), output power of circuits: circuit 1–12: 550 VA AC (4AT) each, max. 120 W DC
Order no.
CENTRAL LPS 720 720 W 1 h 10 JB 32 Ah 4 x 12 V Housing model: 03 22 156 821
720 W 3 h 10 JB 61 Ah 4 x 12 V Housing model: 03 22 156 822
CENTRAL LPS 720 Nport2 Ethernet version 720 W 1 h 10 JB 32 Ah 4 x 12 V Housing model: 03 22 154 548
720 W 3 h 10 JB 61 Ah 4 x 12 V Housing model: 03 22 154 549
CENTRAL LPS 1080 1080 W 1 h 10 JB 32 Ah 6 x 12 V Housing model: 04 22 156 824
1080 W 3 h 10 JB 61 Ah 6 x 12 V Housing model: 04 22 156 825
CENTRAL LPS 1080 Nport4 Ethernet version 1080 W 1 h 10 JB 32 Ah 6 x 12 V Housing model: 04 22 154 551
1080 W 3 h 10 JB 61 Ah 6 x 12 V Housing model: 04 22 154 552
CENTRAL LPS 1440 1440 W 1 h 10 JB 32 Ah 8 x 12 V Housing model: 04 22 156 827
1440 W 3 h 10 JB 61 Ah 8 x 12 V Housing model: 04 22 156 828
CENTRAL LPS 1440 Nport4 Ethernet version 1440 W 1 h 10 JB 32 Ah 8 x 12 V Housing model: 04 22 154 554
1440 W 3 h 10 JB 61 Ah 8 x 12 V Housing model: 04 22 154 555
600
1000
520
920
125°
Typ 3
Ø 9 mm202
900
1590
720
1480
125°
Typ 4
Ø 9 mm 30 mm
40
202
53
ONLITE CENTRAL PHASE DETECTOR
■ Three-phase monitoring module installed in switch cabinet, DIN-rail mounting
■ Checks three-phase systems for undervoltage and phase failure; also detects if neutral conductor goes open-circuit
■ 3 LEDs for status display (mains volt-age applied)
■ 2 change-over contacts ■ Voltage range: 230 V AC, max. volt-
age of outer conductor: 450 V AC Wattage: 15 W Switching contact: 125 V AC/DC, 2 A (60 W) Monitoring window: Unetz 0.6–0.85 Unenn
Order no.
ONLITE central EPD 22 156 808
Suitable for use in EN 50172 compliant installations (DIN VDE0108-100).
90 35
35 59
ONLITE CENTRAL POWER SUPPLY
■ Power supply module for Section central GSM
■ Power: voltage 24 V AC, current 350 mA
■ Switch-cabinet module
L/W/H DB Modules Order no.
ONLITE Power Supply 35/90/59 2 22 156 809
90 35
35 59
ONLITE central LPS
ONLITE CENTRAL PRINTER
■ For printing out test logs ■ Insensitive to interferences and short
interruptions of infrared connection ■ Sturdy, fixed thermo-print line ■ Battery pack and mains unit included
in scope of supply ■ Incl. 4 reels of thermopaper
Order no.
ONLITE IR-Printer 22 154 522
90
467
6
160
ONLITE CENTRAL REMOTE INTERFACE
■ Remote indication of system status via LEDs
■ Emergency lighting installation blocked using lockswitch
■ Max. 24 V AC/DC, max. 2 A ■ Connection to the floating signalling
contact of the central section
Order no.
ONLITE central Remote Interface LPS/CPS 22 154 740
80
32
95
ONLITE CENTRAL INTERFACE FOR LUMINAIRES
■ PLC-DALI module converts the Powerline signal into a DALI signal
■ Lamp faults are reported back to the emergency power supply (section central)
■ 20 physically adjustable addresses ■ SET DC function via PLC to electronic
ballast (emergency lighting level can be adjusted in electronic ballast)
■ Switching and dimming without addi-tional control line
■ With integrated L´ switching input ■ The cable from the emergency power
supply to the PLC may have a max. length of 300 m
■ Input voltage: 230 V AC / 230 V DC Wattage: AC mode < 2 W (without load), DC mode < 0.5 W (without load)
■ Luminaire installation module (max. distance between module and luminaire is 10 m)
Order no.
ONLITE central PLC DALI Interface II 22 162 080
160
149
4,5
21
30
0
2
67
134
5
89 + 0
+10
L'LN
101234567
89
Luminaire address Adresss switch 1 Adress switch 2
1 0 1
2 0 2
3 0 3
. . .
.. .. ..
10 0 10
11 10 1
12 10 2
. . .
.. .. ..
20 10 10
Mains/Netz
Failure/Stˆrung
ZUMTOBEL STAFFDAS LICHT
SEPS 360
Æ
Fuse / Sicherung
L NPE
O3O2 U3U2O1U1
S1 S2 D1 D2Rx GndTx +_
12 14T1
11T3 P1 P2
Relais 122 2421
Relais 232 3431
Relais 3T2
230 V/AC/DC power supply
PLC Powerline communcation
230 V AC/DC
230 V AC/DC
up to 20 luminaires per circuit
ONLITEPLC-Relay
ONLITEPLC-Relay
Adress switch 1
Adress switch 2
Powerline in
230 V~ 50Hz
55
ONLITE CENTRAL RELAY FOR LUMINAIRES
■ PLC relay module switches AC/DC-compatible consumers via the Power-line signal
■ Lamp faults are reported back to the emergency power supply (section central)
■ 20 physically adjustable addresses ■ Switching without additional control
line ■ With integrated L´ switching input ■ Input voltage: 230 V AC / 230 V DC
Wattage: AC mode < 2 W (without load), DC mode < 0.5 W (without load)
■ Luminaire installation module ■ The cable from the emergency power
supply to the PLC may have a max. length of 300 m
Order no.
ONLITE central PLC DALI Relais 22 156 805
190
180
4,5
28
30
0
2
67
134
5
89 + 0
+10
L'LN
101234567
89
Luminaire address Adresss switch 1 Adress switch 2
1 0 1
2 0 2
3 0 3
. . .
.. .. ..
10 0 10
11 10 1
12 10 2
. . .
.. .. ..
20 10 10
Mains/Netz
Failure/Stˆrung
ZUMTOBEL STAFFDAS LICHT
SEPS 360
Æ
Fuse / Sicherung
L NPE
O3O2 U3U2O1U1
S1 S2 D1 D2Rx GndTx +_
12 14T1
11T3 P1 P2
Relais 122 2421
Relais 232 3431
Relais 3T2
230 V/AC/DC power supply
PLC Powerline communcation
230 V AC/DC
230 V AC/DC
up to 20 luminaires per circuit
ONLITEPLC-Relay
ONLITEPLC-Relay
Adress switch 1
Adress switch 2
Powerline in
230 V~ 50Hz
ONLITE CENTRAL ELECTRONIC BALLAST FOR LUMINAIRES
■ PLC electronic ballast module for operating one T5 8 W fluorescent lamp
■ Lamp faults are reported back to the emergency power supply (section central)
■ 20 physically adjustable addresses ■ Switching and dimming without addi-
tional control line ■ Input voltage: 230 V AC / 230 V DC
Power input: AC operation < 11 VA ■ Luminaire installation module ■ The cable from the emergency power
supply to the PLC may have a max. length of 300 m
Order no.
ONLITE central PLC EVG 8 W 22 156 799
230
219
4,5
28
30
ONLITE GO-ON package
IP30
■ Visualisation package for graphic display and monitoring of up to 500 emergency or escape sign luminaires
■ Visualisation software with single user licence enabled
■ Commissioning/configuration of a Section Central or an SB 128 CTP Controller
■ Pre-defined GO plan files for Section Central 360, 720, 1080, 1440 and SB 128 Controller
■ Caption for up to 60 emergency or escape sign luminaires
■ Mouse, German keyboard and Y-plug ■ Rail-mounted PC with external
230 V / 24 V power pack
Order no.
GO-ON package ONLITE visualisation computer 22 154 418
12
1
187 69
63
GO-ON GO GO
RS-232 RS-232 RS-232 RS-232 RS-232 RS-232
RS-232 RS-232
HUB
TCP/IP TCP/IP
Nport4 Nport2
24V/GND DC-IN
VGA MS/KB COM2 COM1
LAN1 LAN2
RS-232 RS-232 RS-232 RS-232
EPS 360 EPS 360 EPS 360 EPS 360
SB 128 SB 128
Client PC
AN TCP IP
RJ 45 crossed network cable
Extension line RS-232 (uncrossed) max. 2 m
ONLITE central LPS
www.zumtobel.com/onlite
ONLITE central CPS
Central Battery System –
safety ensured by modular
large-size unit.
The progress of ONLITE emer-gency lighting systems is based on the strategy - unique in the world – of using any DALI lumi-naire as an emergency luminaire, monitoring it and supplying it with emergency power in case of an emergency. Maintenance work is done fully automatically, faults are displayed clearly.
New, and especially suitable for projects involving more than 100 emergency luminaires: the CPS Central Power System with a mobile monitoring and programming unit, which comes as a touch-sensitive panel with colour display, Ethernet and Web browser link, USB port and multimedia card, relying on state-of-the-art technology as well as utmost convenience, easy operation and flexibility.
57
ONLITE central CPS
ONLITE CENTRAL CPS K
■ Central battery system in compact cabinet
■ Fully automatic execution of tests and documentation in electronic test book
■ 2 x 0–20 circuits, with monitoring of individual luminaires or circuit, also mixed monitoring mode in units of 20
■ All cable outputs have been prewired on a terminal strip
■ 7" Touch PC for operating and visual-ising the installation
■ Ethernet connection for web-browser based system-networking and visuali-zation
■ USB/MMC or SD for test book archiv-ing
■ Sheet steel housing in powder-coated RAL 7035 finish
■ Power per circuit (AC/DC): 1300 W ■ Max. 20 luminaires per circuit ■ In single-luminaire monitoring mode,
each DALI luminaire can be control-led and monitored individually. Mixed operation possible within one circuit.
■ Available models: Left/right door hinge ■ Power can be increased up to 21 kVA ■ 0–7 outlets for sub-stations ■ OGI monobloc batteries 216 V,
7–75 Ah in combi-cabinet with tem-perature-controlled U/I charging
Order no.
ONLITE central CPS K 22 154 689
18
00
600850
CPS K
Battery Batteries CPS-K Total weight
ets 18 blocks CPS-K
(kg) (kg) (kg)
7 Ah 45 180 ~ 225
12 Ah 71 180 ~ 251
17 Ah 107 180 ~ 287
24 Ah 162 180 ~ 342
28 Ah 175 180 ~ 355
33 Ah 211 180 ~ 391
45 Ah 267 180 ~ 447
55 Ah 324 180 ~ 504
75 Ah 432 180 ~ 612
Dimensions (H x W x D) 1800 x 850 x 600 mm
max. 2 outputs for substations
otal power 7 – 30 kVA
Circuits internal 0 – 40
Outgoing units to external UVS max. 7
only possible if there are max. 20 circuits internal)
use protection UVS to 35 A
Outgoing terminals UVS 16 mm²
Battery voltage (18 blocks) 216 V
Battery capacity range 7–75 Ah
thernet port 1
Potential free outputs 5
Digital potential-free inputs 8–16 (per UVS)
ONLITE CENTRAL CPS U
■ Sub-distribution system for emer-gency lighting housed in sheet-steel cabinet in powder-coated RAL 7010 finish
■ 1–20 circuits, monitoring of individual luminaires or circuit
■ All cable outputs have been prewired on a terminal strip
■ Power per circuit (AC/DC): 1300 W ■ Max. 20 luminaires per circuit ■ In single-luminaire monitoring mode,
each DALI luminaire can be control-led and monitored individually. Mixed operation possible within one circuit.
■ Available models: Left/right door hinge ■ E30 model possible RAL 7035
includes cable cooling attachment
Order no.
ONLITE central CPS U E00 22 154 691
ONLITE central CPS U E30 22 154 692
CPS U E00
80
0
300 161
1.3
76
50
2
195374
334CPS U E30
59
ONLITE CENTRAL CPS H
■ Central battery facility housed in sheet steel cabinet in powder-coated RAL 7035 finish
■ Fully automatic execution of tests and documentation in electronic test book
■ 3 x 0–20 circuits, with monitoring of individual luminaires or circuit, also mixed monitoring mode in units of 20
■ All cable outputs have been prewired on a terminal strip
■ Ethernet connection for web-browser based system-networking and visuali-zation
■ 7" Touch PC for operating and visual-ising the installation
■ USB/MMC or SD for test book archiv-ing
■ Power per circuit (AC/DC): 1300 W ■ Max. 20 luminaires per circuit ■ In single-luminaire monitoring mode,
each DALI luminaire can be control-led and monitored individually. Mixed operation possible within one circuit.
■ Please order batteries separately for fitting in external battery box or on battery rack
■ Available models: Left/right door hinge ■ Power increase up to 30 kVA ■ 0–12 outlets for substations
Order no.
ONLITE Central CPS H 22 154 690
18
00
600850
CPS H E00 Rmax. 40 circuits
CPS H E00 Rmax. 60 circuits
600
CPS-H main station technical data
Total power 7 – 30 kVA
Circuits internal 0 – 60
Fuse UVS up to 35 A
Battery outgoing terminals 35 mm²
Battery capacity range 7–200 Ah (ext. battery)
Ethernet port 1
Potential free outputs 5
Digital potential free inputs 8–16
Dimensions (H x W x D) 1800 x 600 x 600 mm
(max. 40 internal circuits; no outputs for substation)
Total weight CPS-H 114 kg
Outgoing units to external UVS max. 12 (240 circuits external)
Dimensions (H x W x D) 1800 x 850 x 600 mm
(max. 60 internal circuits; with outputs for substation)
Outgoing terminals UVS 16 mm²
Total weight CPS-H 180 kg
ONLITE CENTRAL CPS BS
■ Sheet-steel battery cabinet in powder-coated RAL 7035 finish with compartment trays for batteries
■ Electrolyte capture tray built into base of cabinet
■ Temperature sensor can be installed in battery cabinet
■ Connecting leads included with bat-teries
■ OGI monobloc batteries 216 V, 7–200 Ah
■ Available models: Left/right door hinge
Order no.
ONLITE central CPS BS 33–75 Ah 22 154 693
ONLITE central CPS BS 80–134 Ah 22 162 076
ONLITE central CPS BS 120 Ah 22 162 077
ONLITE central CPS BS 150 Ah 22 162 078
ONLITE central CPS BS 190+200 Ah 22 162 079
External battery cabinet (CPS-BS) Set of Batteries CPS-BS CPS-BS Total weight
batteries 18 blocks H x W x D CPS-BS
(kg) (mm) (kg) (kg)
7 Ah 45 1600 x 600 x 600 80 125
12 Ah 71 1600 x 600 x 600 80 151
17 Ah 107 1600 x 600 x 600 80 187
24 Ah 162 1600 x 600 x 600 80 242
28 Ah 175 1600 x 600 x 600 80 255
33 Ah 211 1600 x 600 x 600 80 291
45 Ah 267 1600 x 600 x 600 80 347
55 Ah 324 1600 x 600 x 600 80 404
75 Ah 432 1600 x 600 x 600 80 512
80 Ah 472 1800 x 850 x 600 100 572
90 Ah 540 1800 x 850 x 600 100 640
100 Ah 540 1800 x 850 x 600 100 640
120 Ah 679 1800 x 950 x 600 130 809
134 Ah 765 1800 x 950 x 600 130 895
150 Ah 836 1800 x 1100 x 600 150 986
190 Ah 1800 x 1800 x 600
1167 1800 x 600 x 600 260 1427
200 Ah 1800 x 1800 x 600
1206 1800 x 600 x 600 260 1466
ONLITE central CPS
ONLITE CENTRAL CPS BG
■ PE sinter-coated, fully insulated, acid-resistant longitudinal and transverse supports
■ Height-adjustable feet made of insu-lating plastic
■ Quick, easy and clean to install ■ Withstand voltage to DIN VDE 0100
and DIN VDE 0510 TV ■ Simple grounding facility
L/W/H kg Order no.
Battery rack ONLITE central BG BTX LS 17 600/500/632 27.0 22 154 694
ONLITE central BG BTX LS 24-75 600/715/1074 43.0 22 161 977
ONLITE central BG BTX LS 80-134 1200/500/1074 39.0 22 161 978
ONLITE central BG BTX LS 150 1200/715/1074 50.0 22 161 979
ONLITE central BG BTX LS 190-200 1500/715/1074 67.0 22 161 980
L
H
B
ONLITE CENTRAL monobloc battery
■ OGiV high-rate pasted plates (lead/calcium)
■ DIN EN 60896-2:1997 compliant ■ Absorbent glass mat technology ■ ABS case and lid ■ Recessed threaded bras post termi-
nals ■ E xtremely low gas ■ Low self-discharge ■ 100 % recyclable ■ Units are maintenance free ■ 17–200 Ah capacity in 12 V mono-
blocs
L/W/H Order no.
10-year monobloc battery Accu Pb/10 12 V 7 Ah, connection: Faston 151/65/94 22 162 309
Accu Pb/10 12 V 12 Ah, connection: Faston 151/98/95 22 162 307
Accu Pb/10 12 V 17 Ah, connection: M5 181/77/167 22 154 695
Accu Pb/10 12 V 24 Ah, connection: M5 166/175/125 22 154 696
Accu Pb/10 12 V 28 Ah, connection: M5 165/125/182 22 154 697
Accu Pb/10 12 V 33 Ah, connection: M6 195/130/172 22 154 698
Accu Pb/10 12 V 45 Ah, connection: M6 197/165/170 22 154 699
Accu Pb/10 12 V 55 Ah, connection: M6 239/132/210 22 154 700
Accu Pb/10 12 V 75 Ah, connection: M6 258/166/215 22 154 702
Accu Pb/10 12 V 80 Ah, connection: M6 350/167/179 22 154 703
Accu Pb/10 12 V 90 Ah, connection: M6 306/169/214 22 154 704
Accu Pb/10 12 V 100 Ah, connection: M6 330/171/222 22 154 705
Accu Pb/10 12 V 120 Ah, connection: M8 410/176/277 22 154 706
Accu Pb/10 12 V 134 Ah, connection: M8 342/172/277 22 154 707
Accu Pb/10 12 V 150 Ah, connection: M8 485/172/240 22 154 708
Accu Pb/10 12 V 190 Ah, connection: M8 522/238/223 22 154 709
Accu Pb/10 12 V 200 Ah, connection: M8 522/238/223 22 154 710
Art. no.
battery
rack
for
battery
set
Weight
battery set
[kg]
Positioning
of
batteries
Tiers Rows Height (HB)
above battery
[mm]
22154694 17 Ah 107 horizontal 2 2 830
22161977 24 Ah 162 longitudinal 3 2 1300
28 Ah 175 horizontal 3 2 1300
33 Ah 211 horizontal 3 2 1300
45 Ah 267 horizontal 3 2 1300
55 Ah 324 horizontal 3 2 1300
75 Ah 432 horizontal 3 2 1300
22161978 80 Ah 472 horizontal 3 1 1350
90 Ah 540 horizontal 3 1 1350
100 Ah 540 horizontal 3 1 1350
120 Ah 679 horizontal 3 1 1350
134 Ah 765 horizontal 3 1 1350
22161979 150 Ah 836 horizontal 3 1 1350
22161980 190 Ah 1167 horizontal 3 1 1350
200 Ah 1206 horizontal 3 1 1350
61
www.zumtobel.com/office
www.zumtobel.com/healthcare
www.zumtobel.com/education
www.zumtobel.com/industry
www.zumtobel.com/shop
www.zumtobel.com/sport
www.zumtobel.com/hotel
www.zumtobel.com/parking
www.zumtobel.com/culture
www.zumtobel.com/safety
Art.-Nr. 04 900 033-UK 10/10
© Zumtobel Lighting GmbH
Technical data was correct at time of
going to press. We reserve the right to
make technical changes without notice.
Please contact your local sales office for
further information.
For the sake of the environment:
Luxo Light is chlorine-free paper from
sustainably managed forests and
certified sources.
■ Offices and Communication■ Education and Science■ Presentation and Retail■ Hotel and Wellness■ Art and Culture
■ Health and Care■ Industry and Engineering■ Sport and Leisure■ Transit Areas and Parking■ Orientation and Safety
Zumtobel is the internationally leading supplier of integral lighting solu-
tions for professional interior and exterior lighting applications.
We provide unique customer benefits by integrating technology, design,
emotion and energy efficiency. Under the Humanergy Balance concept,
we combine the best possible ergonomic lighting quality for an indivi-
dual’s wellbeing with the responsible use of energy resources.
The company’s own sales organisa tions in twenty countries, as well as
commercial agencies in fifty other countries, form an international net-
work of experts and design partners providing professional lighting
consulting, design assistance and comprehensive services.
Lighting and sustainability In line with our corporate philosopy “We
want to use light to create worlds of experience, make work easier and
improve communications and safety while remaining fully aware of our
responsibility to the environment”, Zumtobel offers energy-efficient high-
quality products, while at the same time making sure that our production
processes based on the considerate use of resources are environmen-
tally compatible. www.zumtobel.com/sustainability
LIGHT FOR HEALTH AND CARE
LIGHTING FORORIENTATIONAND SAFETY
LIGHT FORSPORTAND LEISURE
LIGHT FORINDUSTRYAND ENGINEERING
LIGHT FORTRANSIT AREAS AND PARKING
LIGHT FOR OFFICESAND COMMUNICATION
LIGHT FOR HOTELAND WELLNESS
LIGHT FOR PRESENTATIONAND RETAIL
LIGHT FOR ART ANDCULTURE
www.natureOffi ce.com / AT-171-731213 www.pefc.org
LIGHT FOR EDUCATION AND SCIENCE
YEAR GUARANTEE
Top quality – with a fi ve-year guarantee.
As a globally leading luminaire manufacturer,
Zumtobel provides a five-year guarantee
for its complete product range with effect from
1 April 2010.
www.zumtobel.com/guarantee
TRACK AND SPOTS
MODULAR LIGHTING SYSTEMS
DOWN-/UPLIGHTS
RECESSED LUMINAIRES
SURFACE-MOUNTED AND PENDANT LUMINAIRES
LED, TASK, WALL AND UPLIGHTS
CONTINUOUS ROW AND BATTEN LUMINAIRES
HIGH-BAY LUMINAIRES
LUMINAIRES WITH EXTRA PROTECTION
LIGHTING MANAGEMENT
EMERGENCY LIGHTING
MEDICAL SUPPLY SYSTEMS
United Kingdom
Zumtobel Lighting Ltd.
Unit 4 - The Argent Centre, Pump Lane
Hayes/Middlesex UB3 3BL
T +44/(0)20 8589 1800
F +44/(0)20 8756 4800
www.zumtobel.co.uk
USA and Canada
Zumtobel Lighting Inc.
Location Highland
3300 Route 9W
Highland, New York 1258-2630
T +1/(0)845/691 62 62
F +1/(0)845/691 62 89
www.zumtobel.us
www.zumtobel.ca
Australia and New Zealand
Zumtobel Lighting Pty Ltd
333 Pacific Highway
North Sydney, NSW 2060
T +61/(2)8913 5000
F +61/(2)8913 5001
www.zumtobel.com.au
China
Zumtobel Lighting China
Beijing Office
T5-2-152 Tayuan
Diplomatic Compound
No. 1 Xin Dong Road,
Chaoyang District
100600 Beijing
T +86/(10) 8532 3886
F +86/(10) 8532 3889
Hong Kong
Zumtobel Lighting Hong Kong
Unit 319, Level 43,
Tower 1, Metroplaza,
223 Hing Fong Road,
Kwai Chung, N.T.
T +852/(0)2503 0466
F +852/(0)2503 0177
India
Zumtobel Lighting GmbH
Branch Office India
S-605, Manipal Centre
Dickenson Road
560042 Bangalore
United Arab Emirates
Zumtobel Lighting GmbH (Branch)
Dubai Airport Free Zone,
Building 6W, B Block, 233
PO Box 54302
Dubai
T +971/(0)4 299 3530
F +971/(0)4 299 3531
Hungary
Zumtobel Lighting Kft
Lomb u. 15.
1139 Budapest
T +36/(1) 35 00 828
F +36/(1) 35 00 829
www.zumtobel.hu
Croatia, Serbia,
Bosnia and Herzegovina
Zumtobel Licht d.o.o.
Radnička cesta 80 – Zagrebtower
10000 Zagreb
T +385/(1) 64 04 080
F +385/(1) 64 04 090
www.zumtobel.hr
Czech Republic and Slovak Republic
Zumtobel Lighting s.r.o.
Jankovcova 2
Praha 7
170 00 Praha
T +420/(2) 66 782 200
F +420/(2) 66 782 201
www.zumtobel.cz
Poland
Zumtobel Licht GmbH Sp.z.o.o.
Przedstawicielstwo w Polsce
ul. Narbutta 46/48
02-541 Warszawa
T +48/(22) 856 7431
F +48/(22) 856 7432
www.zumtobel.pl
Slovenia
Zumtobel Licht d.o.o.
Dunajska cesta 159
1000 Ljubljana
T +386/(1) 56 09 820
F +386/(1) 56 09 866
www.zumtobel.si
Russia
Zumtobel Lighting GmbH
Official Representative Office
Skakovaya Str. 17
Bld. No 1, Office 1104
125040 Moscow
T +7/(495) 945 36 33
F +7/(495) 945 16 94
www.zumtobel.ru
Norway
Zumtobel Belysning
Pilestredet 75 C
0354 Oslo
Postbox 5829 Majorstuen
0308 Oslo
T +47 22 46 85 00
F +47 22 46 85 02
www.zumtobel.no
Sweden
Zumtobel Belysning
Birger Jarlsgatan 57
113 56 Stockholm
T +46 8 26 26 50
F +46 8 26 56 05
www.zumtobel.se
Denmark
Light Makers AS
Indiavej 1
2100 København/Copenhagen
T +45 35 43 70 00
F +45 35 43 54 54
www.lightmakers.dk
Headquarters
Zumtobel Lighting GmbH
Schweizer Strasse 30
Postfach 72
6851 Dornbirn, AUSTRIA
T +43/(0)5572/390-0
F +43/(0)5572/22 826
Zumtobel Licht GmbH
Grevenmarschstrasse 74-78
32657 Lemgo, GERMANY
T +49/(0)5261 212-0
F +49/(0)5261 212-7777
www.zumtobel.de
www.zumtobel.com
www.zumtobel.com/onlite
Emergency lighting
systems with central
power supply.
ONLITE central