CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin...

9
CEKA Impression Technique

Transcript of CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin...

Page 1: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

CEKA

Impression Technique

Page 2: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

CEKA AXIAL CLASSIC

• Male part attached in the mouth

• Female attached in the denture

Page 3: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

Impression technique

RE H 2 (M2)

H2 (M3)

First unthread the spring pin from the mouth.

Then thread in the black impression tool and take an impression.

Page 4: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

Model fabrication

RE H 2 (M2)

H2 (M3)

RE H 14 (M2)

H 14 (M3)

RE H 2 (M2)

H2 (M3)

Thread the model analogue into the impression analogue which is in

the impression and pour out your model.

Remove the impression when the model has hardened.

Remove the impression tool and thread in the spring pin.

Page 5: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

CEKA AXIAL REVERSE

• Female part in the mouth attached to crown or root cap.

Page 6: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

• Female part in the mouth attached to crown or root cap.

CEKA AXIAL REVERSE

Page 7: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

Impression

RE H 14 (M2)

H 14 (M3)

RE 0031 (M2)

694 C (M3)

Female part in the mouth

Thread the spring pin into the impression tool and click the assembled

parts into the female with the space maintainer ring in between.

Page 8: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

Impression

• Take an anatomical impression,allow it to harden andthen remove it from the mouth.

• If the impression analogue and spring pin will not come out of the impression, remove them and place them in the hardened impression material.

Page 9: CEKA Impression Technique · Impression technique RE H 2 (M2) H2 (M3) First unthread the spring pin from the mouth. Then thread in the black impression tool and take an impression.

Model fabrication

RE H 14 (M2)

H 14 (M3)

RE 0031 (M2)

694 C (M3)

RE H 13 (M2)

H 13 (M3)

Click the model analogue over the impression analogue with the space

maintainer ring in between. Then pour out your model.