CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

77
CEILING & WALL SYSTEMS Between us, ideas become reality ® September 2012 CI/SfB (35) Xy Suspension Systems Catalogue 2013 / 2014

Transcript of CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

Page 1: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

CEILING&WALL SYSTEMS

Between us, ideas become reality® September 2012CI/SfB (35) Xy

Suspension Systems Catalogue 2013 / 2014

Page 2: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

SUMMARY ARMSTRONG SUSPENSIONSYSTEMS

Armstrong’s Philosophies 1Armstrong’s Commitment to the Environment 2CE Marking 3Armstrong Projects 4The Range 5

TECHNICAL INFORMATION 6 - 22Fire Tests 16Load Capacity Matrix 20

PRODUCT RANGEDESIGN OPTIONSAxiom Transitions 22Axiom Profiles 24Axiom Classic Canopy 26Axiom Knife Edge Canopy 28Axiom Circle & Curved 30Silhouette 15 XL2 32Interlude 15 XL2 34Microline 36

GENERAL APPLICATIONSPrelude 15 38Prelude 24 XL2 40Prelude 24 TLX 42Prelude Sixty2 44Prelude 35 XL2 46Bandraster 48System Z 50Drywall Grid System 52

CORRIDORDrywall Grid System Shortspan 54Prelude Sixty2 55

SPECIFIC APPLICATIONSClean Room 24 mm Grid System 56Corrosive Resistant 24 mm Grid System 58Seismic Solution 60LongSpan System 62

PERIMETER TRIM AND ACCESSORIESFlexible Perimeter Trim 64Perimeter Solutions - Mineral Ceilings 66Perimeter Solutions - Metal Ceilings 68Accessories 70

Designed forfast and easyinstallation

environment quality/CE marking product innovation service

Page 3: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

1

ARMSTRONG’S PHILOSOPHIES

TOTAL CEILING SOLUTIONSThe suspension system product range forms an integral part ofArmstrong’s total ceiling solutions policy. Armstrong nowoffers its customers and specifiers a complete range of ceilingpanels including mineral, soft fibre, wood and metal and awider choice than ever of suspension systems. Armstrong canprovide solutions for all elements in today’s challengingconstruction environments.

QUALITYSuspension systems are manufactured for Armstrong both byits joint venture company WAVE (Worthington ArmstrongVenture) and through various alliances with other companieswho are regarded as specialists in their fields of engineering.WAVE operates on a global basis, and brings to its variousEuropean operations world class practice on the mosttechnologically advanced equipment.

INTEGRATIONSuspension systems are designed for integration withArmstrong's portfolio of ceiling products, mineral, soft fibre,metal, wood and special solutions.

SERVICESuspension systems are manufactured in three Europeanplants, strategically located to serve all our Europeancustomers. Additionally, both Armstrong and WAVE can drawupon their global manufacturing capabilities for both specialityproducts and manufacturing support.In addition to WAVE’s manufacturing sites, Armstrong stockssuspension systems in distribution centres throughout Europe.This allows our customers the convenience of mixed productshipments, combining suspension systems with otherArmstrong ceiling products, optimising bulk shipments directfrom their manufacturing locations.

WAVEWAVE has three manufacturing locations in Europe, three inthe USA including the facility in Aberdeen, Maryland which isone of the world’s largest grid facilities, plus one in China.

Metal ceiling plants

Mineral fibre plants

Grid plants

Distribution centres

STAFFORD

TEAM VALLEY

MUNSTERMOSCOW

MUMBAI

VALENCIENNES

MADRID

RANKWEILPONTARLIER

LAS VEGAS

BENTON HARBOUR

ABERDEEN / MALVERN

SHANGHAI

Page 4: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

2 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

ARMSTRONG’S COMMITMENT TO THE ENVIRONMENT

Our environmental efforts in the life-cycle of our products start with design.

MANUFACTURING• Suspension system Main Runners and Cross Tees are rotary stitched

by a patented method to deliver extra strength and stability.• All in process scrap is recycled back into the process.• Suspension systems and panels are manufactured at several

locations, thereby reducing transportation costs and environmental impacts associated with transportation.

INSTALLATION• Integrate technology to reduce installation time.• Optimised packaging material - less waste on site.

• Up to 100% of the packaging is made from recycled material.

In several countries, we support the recollection of packaging.

MAINTENANCE• Minimal maintenance and easy to replace.• Armstrong has an expanding portfolio of sustainable

products, these include:

> Hot-dipped galvanised suspension systems providesuperior resistance to rust and corrosion.

DESIGN• Innovative design creates stronger sections.• Reuse of waste materials • Raw materials for ceilings are renewable and abundant in nature.• Recycled content varies by product:- Suspension system - contain 25% post-consumer recycled content

RECYCLE• Suspension systems contain up to 25% post-consumer recycled content• End of Life ceiling tile recycling scheme.

RETHINK PRODUCTS• Continuous development of innovative thin gauge products.

WARRANTY ON USE• A history of quality products.• Various warranty options are available on ceilings systems.

fi

fifi

fi

fi

fifi

Page 5: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

3

CE Marking What is it ?CE stands for Conformité Européenne, which translatedliterally, means “European Conformity”. The CE mark is aproducts “passport” for entry into the EEA (EuropeanEconomic Area) and indicates that the product complies with the requirements of the applicable European Directive.

For construction products the European Directive is theConstruction Products Directive (89/106/ EEC), however, this is being replaced by the Construction ProductsRegulations (305/2011/EU) which will come into full force on 1st July 2013.

The CPD identifies the essential requirements for products(and total projects) such that they are fit for intended use as:

• mechanical resistance and stability;

• safety in case of fire;

• hygiene, health and environment;

• safety in use;

• protection against noise;

• energy economy and heat retention.

For suspended ceilings, the way in which we must testand communicate performance for these essentialrequirements has been defined in EN 13964 SuspendedCeilings – Requirements and Test Methods.

What does this mean?This standard identifies how the ceiling components must be tested against the essential requirements to identify aperformance classification. It also indicates how themanufacturer must ensure that their products maintain theselevels of performance on an ongoing basis.

On 1st July 2007, it becamemandatory for all suspendedceilings and accompanying suspension systems (in thescope of EN 13964) to carry the CE mark and theaccompanying essential requirement test information.

Since 1st July 2007, non-CE marked materials are no longersaleable into the EEA.

BRE BUILDING RESEARCH ESTABLISHMENTAt Armstrong, we’re proud to be a recognised pioneer in greenpractices, with successful methods to produce environmentallypreferable products, prevent pollution and reduce waste. We’re the only UK mineral ceiling manufacturer with a BRE Ecopoint profile – an external certification of our compliance with ISO 14041 and ISO 21930 standards. Our Ecopoint score in 2007 was 0.10, a significant improvement on 2004, and we’re working on lowering it even further.

Page 6: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

4

ARMSTRONG PROJECTS

Armstrong World Industry (USA) - Axiom Circle Canopy

Uttoxeter Cinema (UK) -Coloured Prelude 24

Page 7: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

5

Telefonica Center (SP) - Bandraster

Concordia Hotel (IT) - Axiom C Canopy Dutch Technology Leiden (NL) - System Z

Hospital Ruzomberok (SK) - Clean Room Grid.Medis Office (SI) - Silhouette

Lothar Meyer School (DE)

Page 8: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

6 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

THE SUSPENSION RANGE

The suspension systemsinclude a full range ofsolutions for all ceilingsuspension requirements.

• General applications, a range of standard Prelude 24mm and Prelude 15mm grid systems, Bandraster and Prelude Sixty2 for longer spans. Drywall Grid Systems are available for plasterboard ceilings.

• Designer options including the minimalist grid Silhouette, Microline, Interlude and the Axiom range.

• Specific applications, for clean room and higher humidity environments.

• Perimeter trims and accessories, for most applications.

We also include our comprehensive programme of special size options that is available in most ranges. A range of either stab or hook systems are available to meet the mechanical preferences of the installer.

To complete the portfolio we also offer a technical test programme that provides fire, loadings and environmental accreditation.

Suspension systems are designed for use with a wide variety of Armstrong ceiling products, mineral, soft fibre, metal, wood and special solutions.

Peakform is an innovative design for Main Runners and Cross Tees. The taller Peakform profiles are engineered to create a stronger, more stable suspension system making installation both faster and easier.

Superlock is an industry first staked-on clip for Main Runners which provides tighter, secure bulb-to-bulb connections; connections are confirmed by an audible click; Main Runners are easily disconnected and reconnected laterally.

Page 9: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

7

WHERE INNOVATION MEETS PERFORMANCE

VOICE OF THE CUSTOMERCustomer input is an extremely valuable part of our productinnovation progress. Armstrong hold regular voice ofcustomer work sessions to help develop the most innovativeproducts and systems to meet the customer’s needs.

HOT DIPPED GALVINISED STEEL:Inhibits red rusting better and longer than electro galvanised orpainted systems

• Installation of grid can start before the building is enclosedor HVAC system is operational.

• Long term system performance because entire system ishot dipped galvanised steel.

THIN GAUGE TECHNOLOGY:Up to 50% lighter carton weightthan the competition enableseasier handling on site, plus theadded benefit of the Peakformbulb allows easy cutting of the grid.

DESIGNER GRIDSArmstrong’s designer range, Silhouette, Microline, Interlude, AxiomSystem and Axiom Canopies provide aesthetically enhanced grids.Silhouette creates a level ceiling surface, providing a flushappearance while Interlude gives a clean sophisticated visual thatis created by the unique double reveal. Axiom Profiles andTransitions provide an aesthetic solution for changes in level anda flush transition with plaster margins. Axiom Canopies are aperimeter trim system designed to create “ceiling clouds” inconjunction with full size tiles. Microline is a steel based grid withaluminium extrusion. The exposed sleeve provides a clean and crispvisual plus a practical fluted reveal for flexibility in partition fixing and relocation.

OTHER SYSTEMSOur extensive range of performance grids also includesBandraster, Prelude Sixty2, Prelude 35, System Z andLongSpan. Specific grid solutions such as Clean RoomGrid, Seismic Grid and Corrosive Resistant grid completesArmstrong's suspension solutions.

PHYSICAL DETAILAll grids are made from double-web galvanised steel with asurface finish of baked polyester paint.

STITCHINGAll Prelude componentsfeature a unique“stitched” construction.The two metal layers ofthe vertical web aremechanically locked together in a sophisticated in-lineprocess. Stitching enhances the torsional resistance andgeneral “feel” of the Prelude components.

FULL RANGE OF ACCESSORIESAND PERIMETER SOLUTIONS

Suspension systems are offered with a completerange of commonly required accessories andperimeter solutions.

Page 10: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

8 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

PRELUDE UNIVERSAL MAIN RUNNERThe Prelude Universal Main Runner supports the installation of eitherhook/butt cut or stab/override Cross Tees from one simple inventory of MainRunners. The universal system is available in Peakform design in both 24mmand 15mm widths. The Peakform Universal Main Runners feature a firm, quick and easyassembled Main Runner to Main Runner / bulb-to-bulb connection. Metricsized Main Runners are slotted at 100mm centres for more flexibility. Slots aremachined to receive positive and accurate assembly of either Prelude TL andTLX (hook installation) or Prelude XL2 (stab installation) Cross Tees.

The staked-on Superlock clip allows for Main Runners to be disconnectedand reconnected laterally in low-clearance areas or in the middle of a room.

TL

TLX

PRELUDE XL2

WHERE INNOVATION MEETS PERFORMANCE

ARMSTRONG SYSTEMS

SEISMIC Rx® SYSTEMArmstrong Seismic Rx® System is a fully and independently tested approach to achieving ceiling installations that can withstand the forces associated with significant seismic activity or other severe events. In addition to earthquakes, there are several other industries withassociated risks (e.g. Blast protection) where the use of Seismic Rx®System will provide additional protection for the ceiling e.g.• Nuclear installations• Defence establishments• Chemical installations• Transport installations (with intermittent vibrations)The Seismic Rx® system provides the additional security required forseismic resistance using specifically designed elements for minimisedinstallation complexity with maximum performance.

Page 11: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

9

PRELUDE XL2 “CLICK” INSTALLATIONPrelude XL2 Cross Tees in both 24mm and 15mm widthsfeature an advanced stab system that locates with an audible“click”, ensuring a solid installation at all times. The stab endis precision stamped from a separate piece of high gradesteel permitting an increased accuracy and economy ofproduction over the more conventional integral forming of theCross Tee ends. A selected range of standard Prelude 15/24XL2 Cross Tees feature the new Peakform design.

The Cross Tees are inserted to the right of each otherthrough the Main Runner slots and easily pushed home.

PRELUDE TLXTLX is a new highly engineered staked-on hook system, witha patented clip. Its unique steel-based composite materialand shape provide a stronger and level connection, animproved fire performance and an increased overallstability.TLX Cross Tees are quicker and easier to cut due tothe Peakform section.

When the TLX Cross Tees are inserted to the right of eachother through the Main Runner slots, the TLX clip provides amore secure installation.

PRELUDE TL “HOOK” INSTALLATIONPrelude TL Cross Tees in 15mm width feature an integrallyformed hook nose. This popular installation system has beena feature of Armstrong suspension systems for over 20 yearsand its proven ease of assembly and precise butt cut jointhas been a favourite of installers. Cross Tee alignment isensured by locating the tees to the right hand side of theadjoining section.

Page 12: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

10 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

STANDARD COLOURS

Armstrong suspension system components are manufactured in a range of colours and metal finishes including Global White tocomplement Armstrong ceiling tiles. For complete information call Armstrong Technical Sales.

GLOBAL WHITE SILVER GREY CARRARA PLATINUM BLACK WHITE GLOBAL WHITE BRASS CHROME WHITE GALVANISED BLACK/WHITE (GW) RAL 9006 (SG) (CA) (PN) (BK) RAL9010 (WR) (GW) (BS) (CE) RAL9010 (WR)

Prelude 24 TLX

Prelude 24 XL2

Prelude 15 XL2/TL

Silhouette XL2 6mm

Silhouette XL2 3mm

Interlude

Bandraster

Prelude 35

Prelude Sixty2

Corrosive Resistant

Clean Room Grid

Axiom System

Steel based capping Other than Steel based

Painted perimeter trim items are available in Global White and capped angle T 1924 CA is available in all colours except black/white and galvanised.Please contact Armstrong Technical Sales Group for further details.

Page 13: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

11

COLOUR PALLET

• Stimulate your imagination to create vibrant interior spaces using custom colour solutions.• Choice of more than 180 custom colours upon request.• Available for Prelude 15 and Prelude 24 and specific perimeter trims.

DETAILS

15mm 24mm

15 mm Cross Teeand Main Runner

24 mm Cross Teeand Main Runner

Colour Selection Due to printing limitations, shade may vary from actual product.

*Matt finish items are available as a special order.RAL CLASSIC: Important notice: This ORIGINAL RAL colour chart (card) has gone through stringent quality testing by RAL. Only the use of the individual cards of the registers RAL840-HR (semi matt finish) and RAL 841-GL (gloss finish) will guarantee a reliable manufacture and control of RAL Colours.

RAL 1000 RAL 1001* RAL 1002 RAL 1003 RAL 1004 RAL 1005 RAL 1006 RAL 1007* RAL 1011 RAL 1012 RAL 1013* RAL 1014 RAL 1015*

RAL 1016 RAL 1017 RAL 1018 RAL 1019* RAL 1020 RAL 1021* RAL 1024 RAL 1027 RAL 1028 RAL 1032 RAL 1033 RAL 1034 RAL 2000*

RAL 2001 RAL 2002* RAL 2003 RAL 2004* RAL 2008 RAL 2010 RAL 2011 RAL 2012 RAL 3000* RAL 3001 RAL 3002* RAL 3003 RAL 3004

RAL 3005 RAL 3007 RAL 3009 RAL 3011 RAL 3012 RAL 3013 RAL 3014 RAL 3015 RAL 3016 RAL 3017 RAL 3018 RAL 3022 RAL 3027

RAL 3031 RAL 4001 RAL 4002 RAL 4003 RAL 4004 RAL 4005 RAL 4007 RAL 4008 RAL 4009 RAL 5000 RAL 5001 RAL 5002 RAL 5003*

RAL 5004 RAL 5005 RAL 5007 RAL 5008 RAL 5009* RAL 5010* RAL 5011 RAL 5012* RAL 5013 RAL 5014 RAL 5015* RAL 5018 RAL 5019

RAL 5020 RAL 5021 RAL 5022 RAL 5024 RAL 6000 RAL 6001 RAL 6002 RAL 6003 RAL 6004 RAL 6005 RAL 6006 RAL 6007 RAL 6008

RAL 6009 RAL 6010 RAL 6011* RAL 6012 RAL 6013 RAL 6014 RAL 6015 RAL 6016 RAL 6017 RAL 6018 RAL 6019 RAL 6020 RAL 6021

RAL 6022 RAL 6025 RAL 6026 RAL 6027 RAL 6028 RAL 6029 RAL 6032 RAL 7000 RAL 7001* RAL 7002 RAL 7003 RAL 7004 RAL 7005

RAL 7006 RAL 7008 RAL 7009 RAL 7010 RAL 7011 RAL 7012* RAL 7013 RAL 7015 RAL 7016* RAL 7021* RAL 7022 RAL 7023 RAL 7024

RAL 7026 RAL 7030* RAL 7031* RAL 7032* RAL 7033 RAL 7034 RAL 7035* RAL 7036 RAL 7037 RAL 7038* RAL 7039 RAL 7040* RAL 7044*

RAL 8000 RAL 8001 RAL 8002 RAL 8003 RAL 8004 RAL 8007 RAL 8008 RAL 8011 RAL 8012 RAL 8014* RAL 8015 RAL 8016 RAL 8017

RAL 8019* RAL 8022 RAL 8023 RAL 8024 RAL 8025 RAL 8028 RAL 9001* RAL 9002* RAL 9003* RAL 9004 RAL 9005* RAL 9010* RAL 9011*

RAL 9018* RAL 1023 RAL 2009 RAL 3020 RAL 4006 RAL 5017 RAL 6024 RAL 7042 RAL 7043 RAL 9016* RAL 9017

Page 14: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

12 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

PRODUCT SELECTORby application areas

PRODUCT SELECTORby edge detail compatibility

Area Suspension system solution

Open spaces Axiom Canopy (C/KE/Circle/Curved)Axiom TransitionsBandraster

Reception areas Axiom TransitionsAxiom ProfilesSilhouette 15 mmMicroline 15 mmInterlude 15 mm

Meeting rooms / Individual offices Prelude 24 mmPrelude 15 mm

Circulation areas System Z Microline 15 mmPrelude Sixty2

Retail outlets / industrial manufacturing Prelude 35 XL2

Humid areas Prelude 24 Corrosive Resistant

Healthcare environments Clean Room Grid

Axiom Silhouette Interlude Microline Prelude Prelude Prelude Prelude Sixty2 Prelude Clean Room Corrosive Bandraster System ZTransitions/ 15 15 15 24 XL2 24 TLX 35XL2 ResistantProfiles

Mineral

Vector • • • •

MicroLook • • •

MicroLook BE • • • •

Tegular • • • • • • •

Board • • • • • • • •

SL2 • • • • • •

Metal

Metal Axal Vector • • •

Metal MicroLook 8 • • • • •

Metal MicroLook 16 • •

Metal Tegular 2 • • •

Metal Tegular • • • •8, 11F or 16

Metal Board • • •

Page 15: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

13

TECHNICAL ICONS

Colour Pallet

Accessories

Peakform

Perimeter Trim

Specific Applications/Healthcare Environments

General Applications Designer Grid

Corridor

Page 16: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

14 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

HEALTH AND CLEANLINESS

Did You Know... ?It’s all about Air Quality control:■ The air penetrating the Clean Room can be filtered

depending on the size of the undesired elements.

■ Air can be recycled up to 60 times per hour for the total volume of the space.

■ New air is also introduced to avoid a build up in the concentration of CO2 and maintain enough oxygen for the people working there.

■ Operators in a clean room have to wear equipment such as a clean room suit, caps, gloves, shoe protectors and masks.

■ There are 2 types of rooms:

- rooms with over-pressure, to avoid pollutants from entering (dust, bacteria,…)

- rooms with negative pressure, to avoid various contaminants from escaping to the outside (viruses, bacteria, spores,…).

■ Building materials used in such spaces shall not have a negative impact on the pursuance of cleanliness and should preferably contribute actively to a better

CLEAN ROOMA clean room is a space or a series of spaces where the concentration of particles is controlled in order to minimise theintroduction, generation, retention of particles inside, generally for a specific industrial or research objective, as well as inhealthcare environments. Parameters such as temperature, humidity and relative pressure are also maintained at a preciselevel, as defined in ISO 14644-1.• Clean rooms are classified ISO 1 (cleanest) to ISO 9 depending on the number of particles measured.• The performance is tested to ISO 14644-1 which determines the particle cleanliness class. Although US Federal

Standard 209E has been officially withdrawn, it is continuously used as a reference.

The following table shows the equivalence between the 2 standards.

HEALTHCARE PREMISEIn healthcare premises, it is of critical importance to avoid hospital acquired infections.According to the level of risk, the necessary clean room performance will vary, generally between ISO 5 and ISO 8.All products below:• can be used in ISO 5 environments and are certified against ISO 14644-1;• inhibit growth of bacteria, moulds and yeasts tested against norms NF S 90-351, France, and JIS Z2801, Japan.

Maximum Number of Particles in Air ISO Class (particles in each cubic metre equal to or greater than the specified size)

Particle size > 0.1µm > 0.2 µm > 0.3 µm > 0.5 µm > 1 µm > 5 µm

ISO Class 1 10 2 -

ISO Class 2 100 24 10 4 -

ISO Class 3 1 000 237 102 35 8 Class 1

ISO Class 4 10 000 2 370 1 020 352 83 Class 10

ISO Class 5 100 000 23 700 10 200 3 520 832 29 Class 100

ISO Class 6 1 000 000 237 000 102 000 35 200 8 320 293 Class 1 000

ISO Class 7 352 000 83 200 2 930 Class 10 000

ISO Class 8 3 520 000 832 000 29 300 Class 100 000

ISO Class 9 35 200 000 8 320 000 293 000 Class 1 000 000

US FederalStandard 209E

Some examples of spaces and system solutions:

TYPE OF SPACE CONSTRAINTS SYSTEM SOLUTION* LEVEL OF PERFORMANCE

Operating Theatre Fully air-tight Metal Bioguard Plain Clip-In ISO 3 Flush surface finish with appropriate silicone or mastic joint High pressure water cleanable Anti-microbial

MRI Non-magnetic CLEAN ROOM grid with plastic ISO 5 hold-down clips & Clean Room FL Anti-static

Anti-microbial CLEAN ROOM grid with plastic ISO 5 hold-down clips & Bioguard Acoustic Bioguard treatment Intensive Care Anti-microbial Clean Room grid with plastic hold-down ISO 5Recovery Room Good air-tightness clips Bioguard Acoustic or Metal Bioguard WashableMaternity Good acoustical environment Extra Microperforated Rg 0701 with 0.65 �w sound absorptionLaboratory Premium B15Pharmacy

* Subject to local regulations. Please check with your Armstrong Technical Sales team.

Page 17: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

15

Did You Know... ?System solutions for the pharmaceutical,food and manufacturing industry can befound in our brochure “Solutions for CleanRoom Environments”.

BIOGUARD products have been especiallydesigned for the healthcare sector.

The BIOGUARD paint treatment has additionalactive components which reduce the colony sizeof virulent strains of bacteria, moulds and yeasts.

BIOGUARD products achieve ISO 5 to ISO 3 inaccordance with ISO 14644-1.

BIOGUARD paint has enhanced resistance todisinfectants.

Clean Room Bioguard Bioguard Clean Room FL Metal Bioguard Metal Bioguard Grid Plain Acoustic Extra Plain Microperforated Rg 0701 with Premium B15

Classification Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2, 3 & 4NF S 90-351

Particle ISO 4 ISO 5 ISO 5 ISO 5 ISO 5 ISO 3cleanliness class

Material Aluminium Mineral Mineral Mineral Steel with mineral Steel acoustic infill

Surface PVC Bioguard paint Glass veil with Polyester film EXTRA PLAIN Bioguard paint MICROPERFORATED with Bioguard Rg 0701 with polyester powder Bioguard polyester paint powder paint

Resistance Quaternary Ammonium, Hydrogen Peroxide, Chlorine * Quaternary Ammonium,to disinfectants* Hydrogen Peroxide, Chlorine

Grid and tiles for Clean Room environments

GRID MINERAL METAL

* Not tested

Page 18: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

16 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

FIRE PERFORMANCES

The harmonisation of technicalstandards within Europe, and theintegration of EN13964 (Suspendedceilings – requirements and testmethods) into national legislation,means that there is now one series ofharmonised European test methodsand classifications for the reaction tofire of suspended ceilings.

These new reaction to fireclassifications, or ‘Euroclasses’, aredefined in EN13501-1:2007.

The ‘Euroclasses’ have replaced theold national fire reaction ratings forshowing the performance of ceilings inorder to meet the Construction

Products Directive and nationalbuilding regulation requirements forinternal linings.

As reaction to fire is one of theessential safety requirements identifiedfor suspended ceilings, the Euroclassclassification is one of the mandatoryelements on the CE mark forsuspended ceiling tiles and grids.

The ‘Euroclasses’ rate from A1through to F, with A1 being the bestreaction to fire performance and F theworst.

Each member state then sets theperformance level required for differentareas and building types within their

own building regulations.

Depending upon the reaction to firetest(s) conducted, the rating mayinclude an additional classifications forsmoke production and flamingdroplets. Smoke and flaming dropletsare regulated in some Europeancountries.

Smoke production is rated from s1(the least smoke produced) to s3 (nolimit to amount of smoke produced).

Flaming droplets is rated from d0 (noflaming droplets) to d2 (no limit toflaming droplets).

Throughout Europe, there is arequirement for a building’s structureto be protected from fire. This isprimarily for the structure to remainstable during a fire to allow theoccupants to escape and also toenable fire fighters to work withoutthreat of the building’s collapse. Theduration of the required protection willusually depend upon the height of,and location within, the building (i.e.typical floor, basement, roofconstruction etc), whether there is anyactive methods of fire protection(sprinklers etc) and the type ofconstruction to be protected (steelbeams, timber or mezzanine floorsetc).

A fire protecting suspended ceilingsystem is one of several important

methods of providing the fireprotection which fire degradableelements of the structure require.Ceilings can be used to enable a floorconstruction to meet the duration ofprotection required by the buildingregulations that it could not necessarilyprovide on its own.

There are many national test methodsfor establishing the structural fireprotection performance of asuspended ceiling system, as well asseveral European norms which areacceptable in most Europeancountries. The performance achievedduring testing will be classified in termsof the duration of protection given,typically this in accordance withEN13501-2:2007 for European tests.However, there is not yet one singleEuropean test method which isacceptable to all member states.

Untested products may be assessedby reference to the product attributes

and comparison to similar testedproducts, provided this is supportedby an assessment report from arecognised fire expert and should beprovided with the base test report thatdetails how the product should beinstalled to achieve the assessedperformance. The location and type ofvarious service elements such aslighting fittings, smoke detectors etc,are infinite and the designer andinstaller must satisfy themselves thatthey can be integrated withoutreducing the tested performance ofthe ceiling system. This will usuallyrequire a test report from the fittingmanufacturer or an assessment issuedby the fire authorities. Without thesedocuments the designer or installermay assume an everlastingresponsibility for the fire safety of thebuilding and occupants.

The complete construction andassembly of the test installation isimportant to the success of the test,and Armstrong test many ceiling tilesfor their structural fire performance,but always on Armstrong grid.

There are many other details of thetest construction that must beunderstood and adhered to. Theseinclude:

• main runner and hanger centres

• the type of top fixings and how the hangers are attached to them

• the minimum depth of the ceiling void

• what % of the floor design load is tested

• whether ceiling tile hold-down clips were used.

These details must be included in theinstallation if the tested performance is

to be realised and they should betaken into account when writingspecifications for ceilings intended toprovide structural fire protection.

In the UK the fire performance of floorstructures protected by Armstrongceiling tile and grid systems is given inthe fire assessment document 173816.

This document is based on a largenumber of fire tests conducted onvarious Armstrong ceiling tile and gridtypes. It provides an assessment ofthe performances attainable whenvarious Armstrong tile and gridsystems are installed in accordancewith the appropriate base fire test andthe permitted installation variationsfrom that base test.

The tables opposite give a summary ofthe performances achievable as statedin the assessment document and arecorrect at the time of going to print.

As products may be modified orretested it is essential that theirvalidity is always checked prior toinstallation. Therefore, the currentversion of the assessmentdocument 173816 and the relevantbase test report should always beconsulted prior to the installationof a floor construction to beprotected by an Armstrong ceilingsystem.A full document is always required andmust be read and any limitationsunderstood. Abridged versions mustbe regarded as undesirable as they willnot show the full test details andconstruction.

All Armstrong classificationdocuments are freely available onrequest from the ArmstrongTechnical Sales team.

REACTION TO FIRE

STRUCTURAL FIRE PROTECTION

Page 19: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

17

*AFTBF = an aluminium foil, black tissue faced acoustic pad

Assessed Performance Under Structural Steel Beams - Base Test Report: 134086 (70995 for Clip-In)

Assessed Performance Under Timber Floors - Base Test Report: 167751

Assessed Performance Under Mezzanine Floors - Base Test Report: 120559

Board Tegular MicroLook Tegular 2 Clip-In 3mm CommentsUltima 90 minutes 60 minutes 60 minutes n/a n/a Includes 500 x 500 and 1200 x 300 MicroLook ULTIMAUltima dB 60 minutes 60 minutes 60 minutes n/a n/aUltima OP 30 minutes n/a n/a n/a n/aPerla 60 minutes 60 minutes 60 minutes n/a n/aBioguard Acoustic / Bioguard Plain 60 minutes 60 minutes 60 minutes n/a n/aDune dB 60 minutes

60 minutes60 minutes60 minutes

60 minutes n/an/a

n/an/a

Fine FissuredDune Supreme 60 minutes 60 minutes 30 minutes

30 minutes

n/a n/a Includes Colortone BlackPlain 60 minutes 60 minutes 30 minutes n/a n/a Does NOT include GRAPHISCirrus 60 minutes 60 minutes 30 minutes n/a n/a Does NOT include any CIRRUS Design tilesMezzanine DL 100 60 minutes n/a n/a n/a n/aMetal Plain + Premium B15 or PAD 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* padMetal Standard Perforated Rg 2516 + Premium B15 or PAD

60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad

Metal Microperforated Rd 1522 + Premium B15 or PAD

60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad

Metal Extra Microperforated Rg 0701 + Premium B15 or PAD

60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad

Metal Plain + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad

Metal Standard Perforated Rg 2516 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad

Metal Microperforated Rd 1522 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad

Metal Extra MicroperforatedRg 0701 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad

Board Tegular MicroLook Tegular 2 Clip-In 3mm CommentsUltima 60 minutes 60 minutes 60 minutes n/a n/a

Main runners at 600mm centres onlyUltima dB 60 minutes 60 minutes 60 minutes n/a n/aDune dB 60 minutes 60 minutes 60 minutes n/a n/a

Mezzanine DL 100Dune Supreme

n/a n/a n/an/a

n/an/a n/a

n/aFine Fissured n/a n/a n/a n/a n/aUltima / Ultima dB 30 minutes

30 minutes

30 minutes

30 minutes

30 minutes n/a n/aPerla 30 minutes 30 minutes n/a n/a n/aSierra 30 minutes 30 minutes n/a n/a n/aBioguard Acoustic / Bioguard Plain 30 minutes 30 minutes n/a n/a n/aFine Fissured 30 minutes 30 minutes n/a n/a n/a Includes Colortone BlackPlain 30 minutes 30 minutes n/a n/a n/a Does NOT include GRAPHISCirrus 30 minutes 30 minutes n/a n/a n/a Does NOT include any CIRRUS Design tiles

Board Tegular MicroLook Tegular 2 Clip-In 3mm CommentsUltima / Ultima dB 60 minutes 60 minutes 30 minutes n/a n/aUltima dB 60 minutes 60 minutes 30 minutes n/a n/aDune dB 60 minutes 60 minutes 30 minutes n/a n/a

Mezzanine DL 100Dune Supreme

60 minutes n/a n/an/a

n/an/a

n/an/a

Perla 30 minutes

30 minutes

30 minutes

30 minutes

n/a n/a n/aSierra 30 minutes 30 minutes n/a n/a n/aBioguard Acoustic / Bioguard Plain 30 minutes 30 minutes n/a n/a n/aFine Fissured 30 minutes 30 minutes n/a n/a n/a Includes Colortone BlackPlain 30 minutes 30 minutes n/a n/a n/a Does NOT include GRAPHISCirrus 30 minutes 30 minutes n/a n/a n/a Does NOT include any CIRRUS Design tiles

Building Regulations area (non-residential) Euroclass Old classification

Circulation areasA1 Non-combustibleA2-s3, d2 Limited CombustibilityB-s3, d2 Class 0

Other Rooms (> 30 m2)C-s3, d2

Class 1

Small Rooms (≤ 30 m 2) Class 2D-s3, d2 Class 3

(Product cannot be used) E-d2, F Class 4

Building Regulation performance table – internal linings

Page 20: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

18 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

INSTALLATION & MAINTENANCE

SAFETYArmstrong’s commitment on safety concerns each and every step of our business:

• in our plants & offices, we have implemented rigorous safety policies and procedures to help minimise risk

• for our products, for which we ensure compliance with appropriate European and local safety regulations.

• on the jobsite, safety is crucial for our partners: Armstrong therefore recommends the handling, installation & maintenance of our solutions in accordance with the European standards and/or local regulations, for the safety of the installers & of the end users.

GENERAL ADVICE

Installation of suspended ceiling systems should be carried out inaccordance with Armstrong's current manufacturer's recommendations.

For grid systems there are some specific points that should beconsidered:

- The appropriate type of Cross Tee for the ceiling tile edge detail must be considered.

- The grid systems should be installed in such a way that the loadbearing performance of the grid is not exceeded.

- 'Dynamic' service fittings should be independently supported so notto transfer vibration into the suspension system.

- Armstrong recommend the use of the 'ladder formation' and all our loading data is based on the 'ladder formation'. Using the 'H-formation' will give greater deflection for a given load.

Ladder formation H formation

Yes No

Page 21: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

19

INSTALLATION & MAINTENANCE

POST INSTALLATIONAfter the installation of a suspended ceiling system it is important to ensure that it is properly maintained and that anyadditional works are not detrimental to the performance of the ceiling installation. Maintenance operations must only beundertaken after the technical impact on the ceiling system has been completely evaluated. For example, hangers should notbe removed, adapted or bent without fully understanding the consequences and taking any appropriate mitigating actions.

Armstrong suspension systems do not need any more maintenance than normal painted metal surfaces. However, if cleaningis required dust and superficial dirt can easily be removed with a soft brush or a vacuum cleaner with a brush attachment.For more stubborn marks a lightly dampened cloth or sponge can be used, although never use abrasive products.

Some companies specialise in chemical cleaning solutions. These should only be undertaken after a test on a small hiddenarea of grid proves acceptable.

Most Armstrong suspension systems can be redecorated, however, consideration should be given to the effect on the firereaction performance of the grid. Ceiling tiles should be removed, however, the grid can usually be painted in situ. If a firm ofprofessional decorators is used, assurances should be sought that the necessary performances will be maintained. It shouldbe noted that any repainting would invalidate Armstrong's warranty for the product.

For a copy of Armstrong's Suspension Systems Calculation Guide, please contact Armstrong Technical Sales.

Min 100 mm

2

3

300 mm

1 B

B

A

800

600 1000 A

M

2

51200 mm

6

4

1200 mm1200 mm

Max 600 mm

8

9

7

11

A /B

A/B

12

10

1. Planning grid layout 2. Mark the perimeter trim lines 3. Installation of perimeter trims

4. Mark hanger positions 5. Installation of hangers 6. Positioning Main Runner slots

7. Installation of Main Runners 8. Cross Tees installation right to right 9. Cutting Cross Tees

10. Installation of tiles 11. Measure and cut perimeter tiles

12. Re-tegulating Tegular or MicroLook tiles

B (Main Runner)

B (Main Runner)

Page 22: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

20 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

LOAD CAPACITY MATRIX

Loading is an important property of suspended ceiling grid systems both for the mechanical safety of the suspendedceiling and its visual appearance.

In the EEA, table 6 of the suspended ceiling product standard, EN 13964:2004+A1:2006, defines 3 classes ofdeflection, the best being Class 1 which is L/500 (but no greater than 4mm).

The test method on which the European calculations of loadbearing capacity are based upon is also defined in EN13964, and considers the influence of both deflection and bending moment.

The individual product pages in the second half of this brochure include a table giving the maximum uniformdistributed load, based on different hanger centres, in accordance with Class 1 deflection, as defined in EN13964:2004 + A1:2006.

For markets outside of the EEA different deflection limits are sometimes required. The tables on this page show themaximum uniform distributed load for the deflection limits shown, but taking into account deflection only. Thesevalues are calculated based upon load values determined from laboratory tests in accordance with the EN 13964test method.

For longer spans, some of the criteria shown on this page may give quite large deflection values. Armstrongrecommends a maximum of 4mm deflection between points of suspension for all grid components, irrespective ofspan, for aesthetic reasons. Therefore the numbers in the tables on this page are the maximum loads permitted tomeet the give a deflection criteria (such as L/400) but up to a maximum value of 4mm.

System Load Summary (1200 x 1200 layout) - Max Load kg/m2 - Deflection factor only

System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee

Prelude 24 XL2 314032 A 313051 B 312021 A 13,3 16,8 18,8 22,7 22,7

Prelude 24 TLX 314032 A 133031 132031 13,3 16,8 18,7 22,7 22,7

Prelude 15 XL2 304033 A 303033 B 302033 B 13,1 16,5 18,5 22,3 22,3

Prelude 15 TL 304033 A 103033 A 102033 A 13,1 16,5 18,5 22,3 22,3

Microline CS 25 42 92 WR CS 25 30 42 WR CS 25 20 42 WR 12 15 17 20.5 20.5

Silhouette 15 XL2 804042 G 803042 G 802042 G 11,4 14,4 16,1 19,5 19,5

Interlude 15 XL2 614042 G 613042 G 612042 G 14,5 18,3 20,4 24,7 24,7

Prelude 35 XL2 224042 243042 242042 13,9 17,7 19,8 24 24Prelude 24 Corrosive

284042 143032 142032 13,3 16,8 18,7 22,7 22,7Resistant - TLX

Clean Room 24 EA794044 EA793044 EA792044 12,8 16,3 18,2 22,1 22,1

1200mmspacing

1200mmCross Tees

MRMR

600mm 1

Class Maximun deflection in mmA

1 LB / 500 and not greater than 4,02 LB / 3003 No limit

A The maximun deflection is the accumulative value of the deflection of the substructure component and the deflection of the membrane component.

B L is the span in mm between the suspension components or the suspension points.

Page 23: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

21

System Load Summary (1200x1800 layout) - Max Load kg/m2 - Deflection factor only

System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee

Prelude 24 XL2 314032 A 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3(1800 span)Prelude 24 TLX

314032 A 133432 132031 6,5 7,3 7,3 7,3 7,3(1800 span)

System Load Summary (1800x1800 layout) - Max Load kg/m2 - Deflection factor only

System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee

Prelude Sixty2 24 - XL2 404093 G 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3

Prelude Sixty2 24 - TLX 404093 G 133432 132031 6,5 7,3 7,3 7,3 7,3

1200mmspacing

1800mmCross Tees

MRMR

600mm 1

1800mmspacing

1800mmCross Tees

MRMR

600mm

Page 24: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

22 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Des

ign

Opt

ions AXIOM TRANSITIONS

T 3208 G (1) Axiom Transitions for 3000 50 10 30,00 11,80 36 Tegular/MicroLook

T 3219 G (1) Axiom Transitions channel 3000 50 10 30,00 17,10 36

T 3215 G (1) Axiom Transitions angle 3000 50 10 30,00 15,00 36

T 3210 G (1) Axiom Transitions for 3000 50 10 30,00 11,80 36 Vector tiles

T 3225 G (1) Axiom Transitions plasterboard 3000 50 10 30,00 11,30 36 perimeter trim

Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Axiom Transitions

A 321 G Axiom Transitions suspension clip – straight 79 100 2,10

A 322 G Axiom Transitions suspension clip – angled 62 100 2,10

A 340 G Axiom universal corner clip - 100 2,10

A 338 G Axiom universal splice plate - 100 2,10

A 339 G Axiom universal T bar connector clip - 100 2,10

A 344 G Axiom universal hanging clip - 100 2,10

Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg

25 15

11

50

25 15

8

50

25 19 15

15

50

25 15

15

35

25 15 15

15

50

(1) Also available in colour RAL 9010 (WR).

Note: As Axiom is an aluminium extrusion it should not be used in ceiling assemblies where structural fire protection is required.

All measurements in millimetres. All sizes are nominal.

Accessories for Axiom Transitions

The 5 sections are designed to provide a flush transition between plaster margin and mineral, metal or wooden suspended ceilings.

79 mm

62 mm

Page 25: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

A 321 G

A 322 G

A 338 G

A 339 G

A 340 G

23

Des

ign

Opt

ionsAXIOM TRANSITIONS

System Drawing

Page 26: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

24 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

AXIOM PROFILES

Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg

52 42 06 G (1) Axiom Profiles 50 mm 3000 50 5 15,00 7,80 60

54 42 06 G (1) Axiom Profiles 100 mm 3000 100 5 15,00 11,20 36

56 42 06 G (1) Axiom Profiles 150 mm 3000 150 5 15,00 14,70 30

58 42 06 G (1) Axiom Profiles 200 mm 3000 200 5 15,00 17,80 24

55 14 11 G (1) Axiom Vector Profiles 112 mm 3000 112 5 15,00 12,20 15

T 3213 H (1) Profile plasterboard trim 3000 18,5 10 30,00 5,80 36

Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Axiom Profiles

Accessories for Axiom Profiles

A 334 G (1) Axiom Profiles corner post 50 mm 50 2 0,30

A 335 G (1) Axiom Profiles corner post 100 mm 100 2 0,50

A 336 G (1) Axiom Profiles corner post 150 mm 150 2 0,70

A 337 G (1) Axiom Profiles corner post 200 mm 200 2 0,90

A 345 G (1) Axiom Vector corner post 112 mm 112 2 0,60

A 340 G Axiom universal corner clip 100 2,10

A 338 G Axiom universal splice plate 100 2,10

A 339 G Axiom universal T bar connector clip 100 2,10

A 344 G Axiom universal hanging clip 100 2,10

50

100

150

19

19

19

19

200

112

Des

ign

Opt

ions

(1) Also available in colour RAL 9010 (WR)

Available in 5 heights with a plasterboard trim section, Axiom Profiles are compatible with 24 mm and 15 mm grid systems including designer grid.

Page 27: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

A 344 G

A 339 G

A 340 G

A 344 G

A 334 GA 335 GA 336 GA 337 G A 345 G

A 338 G

25

System Drawing

Des

ign

Opt

ions

(1) Also available in colour RAL 9010 (WR)

AXIOM PROFILES

≤ 200

100

A

Page 28: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

26 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Des

ign

Opt

ions AXIOM C CANOPY

55 14 11 G Axiom Vector MicroLook Tegular Profile

C 3000 G Primary C channel

A WDN 21 H T bar hanger

Cut to size Main Runner 600 mm XL2 Cross Tees

A 345 G Axiom Vector MicroLook Tegular Profile corner post

A 348 G Channel bracket

CA 97 G Clamp for C channel

A 347 G 24 mm XL2 connector clip

A 346 G 15 mm XL2 connector clip

A 339 H Axiom universal T bar connector clip for cut tees with screws

Item Nr. Description

Axiom C Canopy Components

Axiom C Canopy Kits*

Module Grid system 15 mm XL2 Grid system 24 mm XL2

Item Nr. Item Nr.

1200 x 1200 mm AX 22 G15 AX 22 G24

1800 x 1200 mm AX 32 G15 AX 32 G24

1800 x 1800 mm AX 33 G15 AX 33 G24

2400 x 1200 mm AX 42 G15 AX 42 G24

2400 x 1800 mm AX 43 G15 AX 43 G24

2400 x 2400 mm AX 44 G15 AX 44 G24

3000 x 1200 mm AX 52 G15 AX 52 G24

3000 x 1800 mm AX 53 G15 AX 53 G24

3000 x 2400 mm AX 54 G15 AX 54 G24

3000 x 3000 mm AX 55 G15 AX 55 G24

*Ceiling tiles are NOT included in the kit.

1.2m

1.8m

2.4m

3.0m

2.4m 1.8m 1.2m3.0m

4 tiles 6 tiles8 tiles10 tiles

15 tiles 12 tiles 9 tiles

20 tiles 16 tiles

25 tiles

112 mm112 mm

Tegular / MicroLookVector

R E C O M M E N DAT I O N S

Axiom C Canopy should always be installed in accordance with allapplicable building codes and regulations.

• Axiom C Canopy should only be installed on a horizontal plane. They are not approved for exterior installations.

• Axiom C Canopy should always be installed by a minimum of 2 people.

• Read the installation instructions included in the carton carefully before starting the installation.

• Make sure the installation is clean and safe.

• Any additional weights (such as luminaires...) must be independently suspended from the soffit.

• Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing.

!

All measurements in millimetres. All sizes are nominal.

Axiom C Canopy is a perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom C Canopy will define and individualise any space.

Page 29: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

27

Des

ign

Opt

ionsAXIOM C CANOPY

System Drawing

6 Aircraft cables & Grippleconnectors

4 Cornerposts

4 Axiom profiles cut to size

3 C channels cut to size

2 Main Runners cut to size(24 mm or 15 mm)

12 Cross Tees 600 mm XL2

(24 mm or 15 mm)

6 T bar hangers

6 Channel brackets

4 Universal T barconnector clips

8 XL2

connector clips

6 Universal T barconnector clips

OPTION 36 mm Threaded rod*

* not included in the kit

OPTION 2Quick hanger*

OPTION 1Aircraft cable & Gripple connectors

The 1800 mm x 3000 mm module is used as an example only.An installation instruction guide is available. Please contact Armstrong Technical Sales for further details.

Page 30: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

28 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Axiom KE Canopy Components

Axiom KE Canopy Kits*

Item Nr. Description

CS 57 42 06 G Axiom KE Profile

C 3000 G Primary C channel

A WDN 21 H T bar hanger

Cut to size Main Runner 600mm XL2 Cross Tees

CS 57 G Mitre corner piece

A 361 G Mitre corner splice connector

A 348 G Channel bracket

CA 97 G Clamp for C channel

A 347 G 24 mm XL2 connector clip

A 346 G 15 mm XL2 connector clip

A 339 H Axiom universal T bar connector clip for cut tees with screws

A 338 G Axiom universal splice plate

Module Grid system 15 mm XL2 Grid system 24 mm XL2

Item Nr. Item Nr.

1200 x 1200 mm CS AK 22 G15 CS AK 22 G24

1800 x 1200 mm CS AK 32 G15 CS AK 32 G24

1800 x 1800 mm CS AK 33 G15 CS AK 33 G24

2400 x 1200 mm CS AK 42 G15 CS AK 42 G24

2400 x 1800 mm CS AK 43 G15 CS AK 43 G24

2400 x 2400 mm CS AK 44 G15 CS AK 44 G24

3000 x 1200 mm CS AK 52 G15 CS AK 52 G24

3000 x 1800 mm CS AK 53 G15 CS AK 53 G24

3000 x 2400 mm CS AK 54 G15 CS AK 54 G24

3000 x 3000 mm CS AK 55 G15 CS AK 55 G24

*Ceiling tiles are NOT included in the kit.

1.2m

1.8m

2.4m

3.0m

2.4m 1.8m 1.2m3.0m

4 tiles 6 tiles8 tiles10 tiles

15 tiles 12 tiles 9 tiles

20 tiles 16 tiles

25 tiles

AXIOM KE CANOPY

135 mm

106 mm

135 mm

106 mm

Vector

RECOMMENDATIONS

Axiom KE Canopies should always be installed in accordancewith all applicable building codes and regulations.

• Axiom KE Canopies should only be installed on a horizontal plane. They are not approved for exterior installations.

• Axiom KE Canopies should always be installed by a minimum of 2 people.

• Read the installation instructions included in the carton carefully before starting the installation.

• Make sure the installation is clean and safe.

• Any additional weights (such as luminaires...) must be independently suspended from the soffit.

• Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing.

!

Des

ign

Opt

ions

Tegular / MicroLook

All measurements in millimetres. All sizes are nominal.

Axiom KE Canopy is an aesthetic perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom KE Canopy is a quick refurbishment solution, ideal for acoustically challenged or open plenum spaces.

Page 31: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

29

System Drawing

4 Universal T barconnector clips

6 Aircraft cables &Gripple connectors

6 Universal T barconnector clips

8 Corner spliceconnectors

4 Mitre Corners

4 Axiom profilescut to size

3 C channelscut to size2 Main Runners cut to size

(24 mm or 15 mm)

12 Cross Tees 600 mm XL2

(24 mm or 15 mm)

6 T bar hangers

6 Channel brackets

16 Axiomuniversal spliceplates

8 XL2

connector clips

AXIOM KE CANOPY

The 1800 mm x 3000 mm module is used as an example only.An installation instruction guide is available. Please contact Armstrong Technical Sales for further details.

Des

ign

Opt

ions

OPTION 36 mm Threaded rod*

* not included in the kit

OPTION 2Quick hanger*

OPTION 1Aircraft cable & Gripple connectors

Page 32: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

RECOMMENDATIONSAxiom Circle & Curved Canopies should always be installed inaccordance with all applicable building codes and regulations.• Axiom Circle & Curved Canopies should only be installed on a horizontal plane. They are not approved for exterior installations.• Axiom Circle & Curved Canopies should always be installed by a minimum of 2 people.• Read the installation instructions included in the carton carefully before starting the installation.• Make sure the installation is clean and safe.• Any additional weights (such as luminaires...) must be independently suspended from the soffit.• Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing.

30 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

AXIOM CIRCLE & CURVEDD

esig

n O

ptio

ns

Axiom Circle & Curves Components

Axiom Circle & Curved Kits*

Item Nr. Description

Module Grid system 15 mm XL2 Grid system 24 mm XL2

Item Nr. Item Nr.

Circle 1800 CS ACI 33 G15 CS ACI 33 G24

Circle 2400 CS ACI 44 G15 CS ACI 44 G24

Curved 2400 x 1800 CS ACU 43 G15 CS ACU 43 G24

Curved 2400 x 2400 CS ACU 44 G15 CS ACU 44 G24

Curved 3000 x 1800 CS ACU 53 G15 CS ACU 53 G24

Curved 3000 x 2400 CS ACU 54 G15 CS ACU 54 G24

Curved 3000 x 3000 CS ACU 55 G15 CS ACU 55 G24

!

The Axiom Circle & Curved Canopies are an aesthetic perimeter trim system designed to create “ceiling clouds” inconjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Curved and Circle Canopies allow specifiers to play with different planes and levels as well as conceal service elements.

62 42 06 G Axiom Circle and Curved Profile

C3000 G Primary C Channel

30 40 33 A Prelude Peakform Main Runner T15 or

31 40 32 A Prelude Peakform Main Runner T24

30 20 33 B Prelude XL2 Cross Tee 600 mm T15 or

31 20 21 A Prelude XL2 Cross Tee 600 mm T24

AWDN 21 H T bar hanger

A 361 G Splice connector

A 339 H Axiom universal T bar connector clip for cut tees with screws

A 156 G Perimeter fill-in for 15 mm grid

A 246 G Perimeter fill-in for 24 mm grid

A 348 G Channel bracket

CA 97 G Clamp for C Channel

1.8m Ø Canopy

2.4m Ø Canopy 2.4m x 2.4m Canopy 2.4m x 3m Canopy

3m x 3m Canopy

1.8m x 3m Canopy1.8m x 2.4m Canopy

All measurements in millimetres. All sizes are nominal.

*Ceiling tiles are NOT included in the kit.

Tegular / MicroLook

Page 33: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

31

AXIOM CIRCLE & CURVED

Des

ign

Opt

ions

System Drawing

OPTION 36 mm Threaded rod*

OPTION 2Quick hanger*

10 Universal T barconnector clips

6 Universal T barconnector clips

6 Aircraft cables & Gripple connectors

Splice connector

Axiom Profiles cut to size

3 C Channels cut to size12 Cross Tees600 mm XL2

(24 mm or 15 mm)

2 Main Runners cut to size(24 mm or 15 mm)

6 T bar hangers

6 Channel brackets

* not included in the kit

The 1.8 x 2.4 m module is used as an example only.An installation instruction guide is available.Please contact Armstrong Technical Sales for further details.

OPTION 1Aircraft cable & Gripple connectors

Page 34: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

32 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

SILHOUETTE 15 XL2

with 6 mm reveal80 40 42 G(1) 3600 44 20 72,00 24,50 3680 39 43 G(1) 3125 44 20 62,50 25,40 2580 44 42 G(1) 2700 44 20 54,00 18,40 30

with 3 mm reveal81 40 42 WRG(2) 3600 44 20 72,00 24,50 36

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

with 6 mm reveal80 30 42 G(1) 1200 44 60 72,00 24,50 3580 31 43 G(1) 1250 44 60 75,00 23,80 3580 33 42 G(1) 1350 44 30 40,50 13,80 5080 32 42 G(1) 1000 44 60 60,00 20,40 24

80 20 42 G(1) 600 44 60 36,00 12,70 7080 21 43 G(1) 625 44 30 37,50 16,00 7080 23 42 G(1) 675 44 60 40,50 14,30 7080 22 42 G(1) 500 44 60 30,00 10,60 7080 24 42 G(1) 300 44 120 36,00 34,00 70

with 3 mm reveal81 30 42 WRG(2) 1200 44 60 72,00 24,50 35

81 20 42 WRG(2) 600 44 60 36,00 12,70 70

All products standard in Global White unless indicated by index (2). Other standard colours available for itemnumbers with index (1). See details below.(1) Silhouette with 6 mm reveal is available in white, black (BK) or white with black reveal (BI).(2) WR = White RAL 9010 (WR)

675 / 625 / 600 / 500 / 300

1350 675 675 1250 625 6251200 600 6001000 500 500

Main Runners Silhouette 15

Cross Tee Silhouette 15 XL2

Cross Tee Silhouette 15 XL2

3600 300 600 3 x 600 600 3003500 250 500 4 x 500 500 2503125 312,5 625 2 x 625 625 312,52700 337,5 675 675 675 337,5

Length

Length

All measurements in millimetres. All sizes are nominal.

Main Runners Silhouette 15 (by-pass connection)

Peakform Cross Tees Silhouette 15 XL2 (stab system)

Section Drawings

Exposed 15 mm grid system (nominal).Silhouette 15 XL2 is a suspension system designed to create a crisp, clean look in conjunction with MicroLooktiles to provide an enhanced aesthetic.

Des

ign

Opt

ions

Page 35: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

33

SILHOUETTE 15 XL2

Silhouette 15 XL2

Grid Load Capacity

- Pre-mitred intersections- Choice of either 6 or 3 mm reveal dimension- Silhouette 15 XL2 with 3 mm reveal is supplied as standard in RAL 9010 white to compliment Armstrong metal tiles

8

424

MCC4 GMitre closure clip for 6 mm reveal

View of mitred intersection from beneath

Section

Section

Axiom Profiles(50, 100, 112, 150 and 200 mm heights available)

Silhouette 15 XL2 system

A 339 GAxiom universal T bar connector clip

Cross Tee trimmed to wall angle

Cross Tee trimmed to shadowline T 1508 HB at perimeter

Perimeter Solutions

Silhouette 15 XL2 System The following table gives the maximum permitted hanger distance (mm) along the Silhouette Main Runner (80 40 42 G) for the tile weights and Main Runner spacings noted.

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

7,0 kg/m2

8,5 kg/m2

10,5 kg/m2

13,0 kg/m2

Main Runner spacing 1200 mm 1200 mm XL2 Cross Tee

80 30 42 G

1800

1700

1650

1600

1500

1450

1400

1300

1200

1100

950

Main Runner spacing 600 mm 600 mm XL2 Cross Tee

80 20 42 G

2100

2100

2050

2000

1900

1850

1800

1700

1600

1550

1350

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Hanger spacing

Availability of products may vary according to location.Please contact Armstrong Technical Sales for further details.

Des

ign

Opt

ions

Page 36: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

34 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Des

ign

Opt

ions INTERLUDE 15 XL2

TZ 61 40 42 3600 44 20 72,00 23,60 36

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Main Runner Interlude 15 (by-pass connection)

Cross Tees Interlude 15 XL2 (stab system)

Section Drawings

Cross Tees slotted61 30 42 G 1200 44 60 72,00 30,30 42

Cross Tees unslotted61 20 42 G 600 44 60 36,00 15,00 84

TZ 61 24 42 300 44 120 36,00 15,00 84

600 / 300

1200 600 600

3600 75 150 22 x 150 75

Main Runner Interlude 15

Cross Tee Interlude 15 XL2

Cross Tee Interlude 15 XL2

Length

Length

Product available as standard in Global White.All measurements in millimetres. All sizes are nominal.

Exposed 15 mm grid system (nominal).Interlude 15 XL2 is a suspension system developed for creative ceiling solutions, and quick and easy installation.

Page 37: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

35

Des

ign

Opt

ionsINTERLUDE 15 XL2

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

Interlude 15 XL2

Interlude 15 XL2 can be easily field cutwith snips in 3 simple steps:

- The stepped flange profile provides a unique double reveal visual- Unmitred intersections allow for Cross Tee installation at any

Main Runner slot position

Grid Load Capacities

Interlude 15 XL2 systemThe following table gives the maximum permitted hanger distance (mm) along the Interlude Main Runner (TZ 61 40 42) for the tile weights and Main Runner spacings noted.

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

7,0 kg/m2

8,5 kg/m2

10,5 kg/m2

13,0 kg/m2

Main Runner spacing 1200 mm 1200 mm XL2 Cross Tee

61 30 42 G

1950

1850

1750

1750

1650

1600

1550

1450

1350

1250

1100

Cross Tee trimmed to wall angle

Section

Section

Perimeter Solutions

Partition Head Fixing

Cross Tee trimmed to shadowlineT 1508 HB

1. Cut down through bulb and web

2. Snip flanges

3. Bend away from bulb to snap off centre rail

UPC AG Universal partition clipattaches to grid to provide fixingfor partition head track: reversible for15 mm or 24 mm grid systems

Main Runner spacing 600 mm 600 mm XL2 Cross Tee

61 20 42 G

2100

2100

2100

2100

2050

2000

1950

1850

1750

1650

1550

Hanger spacing1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Page 38: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

36 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Des

ign

Opt

ions MICROLINE 15 XL2

CS 25 42 92 WR 600* 3000 49 20 60 23,00 32*slotted at 600 mm

CS 25 42 92 WR 750* 3000 49 20 60 23,00 32

*slotted at 750 mm

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Main Runners Microline 15 (bulb-to-bulb connection)

Cross Tees Microline 15 XL2 (stab system)

Section Drawings

Cross Tee slotted (at 600 mm)

CS 25 30 42 WR 1200 44 60 72 26,00 72

Cross Tees unslotted

CS 25 20 42 WR 600 44 60 36 13,00 144

CS 25 16 42 WR 750 44 60 45 16,00 144

Main Runners Microline 15

Cross Tee Microline 15 XL2

Cross Tee Microline 15 XL2

All dimensions are nominal (millimeters).

Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.

Steel based grid with aluminium extrusion. The exposed sleeve provides a clean and crisp visual plus a practical fluted reveal for flexibility in partition fixing and relocation.

3000 300 3 x 600 600 300

3000 375 2 x 750 750 375

1200 600600

600/750

15 mm

49 mm

15 mm

44 mm

15 mm

44 mm

Page 39: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

37

Des

ign

Opt

ionsMICROLINE 15 XL2

Key Attributes Physical Data

Perimeter Options*

• Peakform Patented universal Main Runner and Cross Tee design increase strength and stability for improved performance and makes the grid easier to cut. The aluminium sleeves must be cut aside using a hand saw.

• For metal tiles with MicroLook 8mm edge

• Fluted reveal for M6 bolt

• Material Chassis : Double web galvanised steel Sleeve : Extruded aluminium

• Surface finish of the sleeve Baked polyester paint

• Product Family Designer grids

• Main Runner / Cross Tee Interface Pre-mitred intersections

• End Detail Main Runner : bulb-to-bulb connection Cross Tees : staked-on stab clip

• Colour Available in white (RAL9010) only

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

Grid Load Capacities

40

20

T 2040 H WR APerimeter channel and perimeter wedge for cut modules

C 1803 H

T 2040 H WR A Perimeter channel RAL 9010 3050 20 61,00 18,10

C 1803 H Perimeter wedge 200 100 - 5,00

*Made up of steel

Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs lm kg

Microline XL2 System The following table gives the maximum permitted hanger distance (mm) along the Main Runner

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

4,5 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

6,5 kg/m2

7,0 kg/m2

8,0 kg/m2

9,0 kg/m2

10,0 kg/m2

14,0 kg/m2

1200 mmXL2 Cross Tee CS 25 30 42

1950

1950

1850

1750

1650

1600

1500

1450

1400

1350

1250

1200

1150

-

750 mmXL2 Cross Tee CS 25 16 42

2200

2200

2200

2200

2050

1950

1900

1800

1750

1700

1600

1500

1400

1200

600 mmXL2 Cross Tee CS 25 20 42

2350

2350

2350

2350

2300

2200

2100

2000

1950

1850

1750

1650

1600

1350

Hanger spacing 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Page 40: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

38 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Gen

eral

App

licat

ions PRELUDE 15

30 40 33 A(1) 3600 43 20 72,00 22,50 3230 41 33 A(1) 3750 43 20 75,00 23,20 3230 43 33 A 3375 43 20 67,50 22,50 32

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Universal Main Runners Prelude 15 Peakform and Superlock Clip (bulb-to-bulb connection)

Cross Tees Prelude 15 XL2 (stab system, override)

Cross Tees Prelude 15 TL (hook system, butt cut)

Section Drawings

Cross Tees slotted30 30 33 B(1) 1200 38 60 72,00 20,70 7230 31 33 A 1250 38 60 75,00 21,50 7230 32 33 (2) 1000 38 60 60,00 17,20 72

Cross Tees unslotted30 20 33 B(1) 600 38 60 36,00 10,30 14430 21 33 A 625 38 60 37,50 10,70 14430 22 33 (2) 500 38 60 30,00 8,60 144

Cross Tees slotted10 34 33 B 1800 38 30 54,00 15,20 20 10 36 33 A 1500 38 30 45,00 14,00 20 10 33 33 1350 38 60 81,00 26,00 72 10 31 33 B(1) 1250 38 60 75,00 21,60 72 10 30 33 A(1) 1200 38 60 72,00 20,70 72

Cross Tees unslotted10 23 33 675 38 60 40,50 13,00 144 10 21 33 B(1) 625 38 60 37,50 10,70 144 10 20 33 A(1) 600 38 60 36,00 10,30 144 10 25 33 312,50 38 120 37,50 12,50 144 10 24 33 A 300 38 120 36,00 11,50 144 10 12 32 150 38 60 9,00 2,84 144

3750 78,125 156,25 21 x 156,25 156,25 78,125 3600 50 100 33 x 100 100 503375 337,5 675 2 x 675 675 337,5

1250 312,5 2 x 312,5 312,51200 300 2 x 300 3001000 250 2 x 250 250

625 / 600 / 500 675 / 625 / 600 / 312,5 / 300 /150

Length

Length

1800 300 4 x 300 3001500 300 3 x 300 3001350 337,5 2 x 337,5 337,51250 312,5 2 x 312,5 312,51200 300 2 x 300 300

Length

Universal Main Runners Prelude 15

Cross Tee Prelude 15 XL2

Cross Tee Prelude 15 XL2

Cross Tee Prelude 15 TL

Cross Tee Prelude 15 TL

All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.

(1)Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).

(2) Also available in RAL 9010 (WR).Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.All measurements in millimetres. All sizes are nominal.

Exposed 15 mm grid system (nominal).

Page 41: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

39

Gen

eral

App

licat

ionsPRELUDE 15

System Drawing (module 600 x 600 mm)

Standard lay-in installation of 15 mm exposed suspensionsystem for MicroLook tiles andspecific Board tiles.

*reduce to 450 if heavy tile /overlays are used or heavyservice fittings are locatednear the perimeter.

Grid Load Capacities

Prelude 15 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (30 40 33 A) for the tile weights andMain Runner spacings noted.

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

7,0 kg/m2

8,5 kg/m2

10,5 kg/m2

13,0 kg/m2

Main Runner spacing 1200 mm

1200 mm TLCross Tee

10 30 33 A

1900

1800

1750

1650

1550

1550

1500

1400

1300

1150

1050

Main Runner spacing 600 mm

600 mm TL Cross Tee

10 20 33 A

2100

2100

2100

2050

2000

1950

1900

1800

1700

1600

1500

Main Runner spacing 1200 mm

1200 mm XL2 Cross Tee

30 30 33 B

1900

1800

1750

1650

1550

1550

1500

1400

1300

1150

1050

Main Runner spacing 600 mm

600 mm XL2 Cross Tee

30 20 33 B

2100

2100

2100

2050

2000

1950

1900

1800

1700

1600

1500

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Tile Main Runner Hanger centres Main Runner Cross Tee Cross Tee Hanger Universal centres 1200 mm 600 mm retaining clip

600 x 600 mm 2,78 pcs

1200 x 600 mm 1,39 pcs

6 1 2 3 4 7

5 The chart is for general guidance only.

Quantities required per 1m2 (no waste included)

Perimeter trim approx. 0,70 lm/m2

1200 mm

600 mm

1200 mm

600 mm

1200 mm

1200 mm

1200 mm

1200 mm

0,84 lm

1,67 lm

0,84 lm

1,67 lm

1,67 lm

-

1,67 lm

-

0,84 lm

1,67 lm

-

0,84 lm

0,70 pcs

1,40 pcs

0,70 pcs

1,40 pcs

5,56 pcs

5,56 pcs

5,56 pcs

5,56 pcs

Hanger spacing

Page 42: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

40 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Gen

eral

App

licat

ions

31 40 32 A(1) 3600 43 20 72,00 21,00 3031 41 33 B(1) 3750 43 20 75,00 21,90 3031 43 33 A 3375 43 20 67,50 20,00 3031 42 32 3000 43 20 60,00 17,50 30

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)

Cross Tees Prelude 24 XL2 (stab system, override)

Section Drawings

Cross Tee Prelude 24 XL2

31 33 31 1350 38 60 81,00 17,20 2031 31 51 B(1) 1250 38 60 75,00 18,90 7231 30 51 B(1) 1200 38 60 72,00 18,20 7231 32 31(2) 1000 38 60 60,00 15,10 42

31 34 31 A 1800 38 30 54,00 17,00 20

31 16 32 750 38 60 45,00 14,70 7231 25 32 312,50 38 60 18,75 4,60 14431 24 32 300 38 60 18,00 4,60 14431 23 21 675 30 60 40,50 7,70 14431 21 23 A(1) 625 30 60 37,50 8,60 14431 20 21 A(1) 600 30 60 36,00 8,20 14431 22 21(2) 500 30 60 30,00 6,80 84

3750 78,125 156,25 21 x 156,25 156,25 78,1253600 50 100 33 x 100 100 503375 337,5 675 2 x 675 675 337,53000 50 100 27 x 100 100 50

1800 300 4 x 300 3001350 337,5 2 x 337,5 337,51250 312,5 2 x 312,5 312,51200 300 2 x 300 3001000 250 2 x 250 250

750 / 675 / 625 / 600 / 500 / 312,50 / 300

Cross Tee Prelude 24 XL2

Length

Length

Universal Main Runners Prelude 24

All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).(2) Also available in RAL 9010 (WR).Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.All measurements in millimetres. All sizes are nominal.

PRELUDE 24 XL2

Cross Tees slotted

Cross Tees unslotted

Exposed 24 mm grid system (nominal).

Page 43: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

41

Gen

eral

App

licat

ions

Tile Main Runner Hangers Main Runner Cross Tee Cross Tee Hanger Universal centres centres 1200 mm 600 mm retaining clip

1200 x 600 mm 1,39 pcs

600 x 600 mm 2,78 pcs

PRELUDE 24 XL2

System Drawing (module 1200 x 600 mm)

*

6 1 2 3 4 7

5

Standard lay-in installation of 24 mm exposed suspension systemusing Board, Tegular or Vector tiles.

Grid Load Capacities

Prelude 24 XL2 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (31 40 32 A) for the tile weights and Main Runner spacings noted.

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

7,0 kg/m2

8,5 kg/m2

10,5 kg/m2

13,0 kg/m2

Main Runner spacing 1800 mm 1800 mm XL2 Cross Tee

31 34 31 A

1650

1600

1500

1450

1350

1350

1250

-

-

-

-

Main Runner spacing 1200 mm

1200 mm XL2 Cross Tee

31 30 51 B

1900

1800

1750

1700

1600

1550

1500

1450

1300

1200

1050

Main Runner spacing 600 mm

60 mm XL2 Cross Tee

31 20 21 A

2100

2100

2100

2100

2000

1950

1900

1800

1700

1600

1500

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

The chart is for general guidance only.

Quantities required per 1m2 (no waste included)

Perimeter trim approx. 0,70 lm/m2

1200 mm

600 mm

1200 mm

600 mm

1200 mm

1200 mm

1200 mm

1200 mm

0,84 lm

1,67 lm

0,84 lm

1,67 lm

1,67 lm

-

1,67 lm

-

-

0,84 lm

0,84 lm

1,67 lm

0,70 pcs

1,40 pcs

0,70 pcs

1,40 pcs

5,56 pcs

5,56 pcs

5,56 pcs

5,56 pcs

Hanger spacing

*reduce to 450 if heavy tile /overlays are used or heavyservice fittings are locatednear the perimeter.

*

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Page 44: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

42 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

PRELUDE 24 TLX

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet Length (mm) Height (mm) pcs lm kg

Cross Tees Prelude 24 TLX (Hook system, butt cut)

Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)

900 / 750 / 675 / 625 / 600 / 500

Cross Tee Prelude 24 TLX

Section Drawings

31 40 32 A(1) 3600 43 20 72,00 21,00 3031 41 33 B(1) 3750 43 20 75,00 21,90 3031 43 33 A 3375 43 20 67,50 20,00 3031 42 32 3000 43 20 60,00 17,50 30

Cross Tees slotted13 31 31(1) 1250 38 60 75,00 18,90 72 13 30 31(1) (2) 1200 38 60 72,00 18,10 72 13 60 31 600 38 60 36,00 9,10 144

13 10 32 1875 38 30 56,20 17,80 20 13 34 32 1800 38 30 54,00 17,10 20 13 50 32 1724 38 30 51,70 16,50 20 13 36 32 1500 38 30 45,00 14,50 20 13 33 31 1350 38 60 81,00 19,60 2013 32 32 1000 38 60 60,00 19,40 72

Cross Tees unslotted13 18 31 900 38 60 54,00 13,60 72 13 16 31 750 38 60 45,00 11,40 7213 21 31(1) 625 38 60 37,50 9,50 144 13 20 31(1) (2) 600 38 60 36,00 9,10 144

13 23 31 675 38 60 40,50 8,70 144 13 22 32 500 38 60 30,00 9,70 80

3750 78,125 156,25 21 x 156,25 156,25 78,1253600 50 100 33 x 100 100 503375 337,5 675 2 x 675 675 337,53000 50 100 27 x 100 100 50

Length

Universal Main Runners Prelude 24

Cross Tee Prelude 24 TLX

1875 312,5 4 x 312,5 312,51800 300 4 x 300 3001724 262 4 x 300 2621500 150 350 / 2 x 250 / 350 1501350 337,5 2 x 337,5 337,51250 312,5 2 x 312,5 312,51200 300 2 x 300 3001000 250 2 x 250 250

Length

All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE) and White RAL 9010 (WR). (2) Also available in Black (NG), Brown (MR) and Beige (BJ).Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.

Exposed 24 mm grid system (nominal).

Gen

eral

App

licat

ions

Page 45: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

43

Gen

eral

App

licat

ions

Tile Main Runner Hanger Main Runner Cross Tee Cross Tee Hanger Universal centres centres 1200 mm 600 mm Retaining Clip

1200 x 600 mm 1,39 pcs

600 x 600 mm 2,78 pcs

System Drawing (module 1200 x 600 mm)

6 1 2 3 4 7

5

Standard lay-in installation of 24 mm exposed suspension system using Board, Tegular orVector edge tiles.

The chart is for general guidance only.

Quantities required per 1m2 (no waste included)

Perimeter Trim approx. 0,70 lm/m2

1200 mm

600 mm

1200 mm

600 mm

1200 mm

1200 mm

1200 mm

1200 mm

0,84 lm

1,67 lm

0,84 lm

1,67 lm

1,67 lm

-

1,67 lm

-

-

0,84 lm

0,84 lm

1,67 lm

0,70 pcs

1,40 pcs

0,70 pcs

1,40 pcs

5,56 pcs

5,56 pcs

5,56 pcs

5,56 pcs

PRELUDE 24 TLX

Grid Load Capacities

Prelude 24 TLX System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (31 40 32 A) for the tile weights and Main Runner spacings noted.

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

7,0 kg/m2

8,5 kg/m2

10,5 kg/m2

13,0 kg/m2

Main Runner spacing 1800 mm 1800 mm TLXCross Tee

13 34 32

1650

1600

1500

1450

1350

1350

1250

-

-

-

-

Main Runner spacing 1200 mm 1200 mm TLXCross Tee

13 30 31

1900

1800

1750

1700

1600

1550

1500

1450

1300

1200

1050

Main Runner spacing 600 mm 600 mm TLX Cross Tee

13 20 31

2100

2100

2100

2100

2000

1950

1900

1800

1700

1600

1500

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

Hanger spacing

*reduce to 450 if heavy tile / overlaysare used or heavy service fittings arelocated near the perimeter.

*

Page 46: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

44 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

PRELUDE SIXTY2

Gen

eral

App

licat

ions

Universal Main Runner Prelude Sixty2 Double Peakform with Superlock Clip (bulb to bulb connection)

3750 156,25 11 x 312,5 156,253600 150 11 x 300 1503375 168,75 9 x 337,5 168,75

Length

Universal Main Runner Prelude Sixty2

40 40 93 G(1) 3600 62 12 43,20 21,90 36

40 41 93 G(1) 3750 62 12 45,00 22,80 36

40 43 93 G(1) 3375 62 12 40,50 20,60 36

Cross Tees Prelude 24 TLX (hook system, butt cut)

Cross Tees slotted13 31 31(1) 1250 38 60 75,00 18,90 7213 30 31(1) (2) 1200 38 60 72,00 18,10 7213 60 31 600 38 60 36,00 9,10 144

13 10 32 1875 38 30 56,20 17,80 20 13 34 32 1800 38 30 54,00 17,10 20 13 50 32 1724 38 30 51,70 16,50 20 13 36 32 1500 38 30 45,00 14,50 2013 33 31 1350 38 60 81,00 19,60 20 13 32 32 1000 38 60 60,00 19,40 72

Cross Tees unslotted13 18 31 900 38 60 54,00 13,60 7213 16 31 750 38 60 45,00 11,40 7213 21 31(1) 625 38 60 37,50 9,50 144 13 20 31(1) (2) 600 38 60 36,00 9,10 144

13 23 31 675 38 60 40,50 8,70 144 13 22 32 500 38 60 30,00 9,70 80

Cross Tees Prelude 24 XL2 (stab system, override)

Cross Tees slotted31 33 31 1350 38 60 81,00 17,20 2031 31 51 B(1) 1250 38 60 75,00 18,90 7231 30 51 B(1) 1200 38 60 72,00 18,20 7231 32 31(3) 1000 38 60 60,00 15,10 42

31 34 31 A 1800 38 30 54,00 17,00 20

Cross Tees unslotted31 16 32 750 38 60 45,00 14,70 72 31 25 32 312,50 38 60 18,75 4,60 14431 24 32 300 38 60 18,00 4,60 14431 23 21 675 30 60 40,50 7,70 14431 21 23 A(1) 625 30 60 37,50 8,60 144 31 20 21 A(1) 600 30 60 36,00 8,20 144 31 22 21(3) 500 30 60 30,00 6,80 84

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet Length (mm) Height (mm) pcs lm kg

All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).(2) Also available in Black (NG), Brown (MR), Beige (BJ).(3) Also available in RAL 9010 (WR).All measurements in millimetres. All sizes are nominal.

Exposed 24 mm grid system (nominal).Double Peakform Main Runner section requiring less suspension points and compatible with Prelude 24 XL2 and TLX Cross Tees. For corridor applications please see page 50 - 51.

Page 47: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

45

PRELUDE SIXTY2

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

Accessories

Item Nr. Description Dimensions Content/Carton Weight/Carton Length (mm) Height (mm) pcs kg

A 401 G Top Connector Clip accessory for - - - - Prelude Sixty2 (Included in the carton)

A WDN 23 G Double bent tee bar hanger 57 36 100 2,30

Tile Main Runner centres Main Runner Cross Tee 1800 mm Cross Tee 1200 mm Cross Tee 600 mm

System Drawing (module 1800 x 300 mm)

3 1 2 2 2

The chart is for general guidance only.

Quantities required per 1m2 (no waste included)

1800 x 300 mm

600 x 600 mm

1200 x 600 mm

1800 mm

1800 mm

1200 mm

600 mm

1200 mm

600 mm

0,56 lm

0,56 lm

0,84 lm

1,67 lm

0,84 lm

1,67 lm

3,34 lm

1,67 lm

-

-

-

-

-

-

1,67 lm

-

1,67 lm

-

-

1,12 lm

0,84 lm

1,67 lm

-

0,84 lm

Grid Load Capacities

Prelude Sixty2 System The following table gives the maximum permitted hanger distance (mm) along the double Peakform Main Runner (40 40 93 G) for the tile weights and Main Runner spacings noted.

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

7,0 kg/m2

8,5 kg/m2

10,5 kg/m2

13,0 kg/m2

Main Runner spacing 1800 mm 1800 mm Cross Tees31 34 31 A/13 34 32

2300

2200

2150

2100

2000

1900

1850

-

-

-

-

Main Runner spacing 1200 mm 1200 mm Cross Tees31 30 51 B/13 30 31

2400

2400

2350

2300

2200

2150

2100

2050

1900

1700

1550

Main Runner spacing 600 mm 600 mm Cross Tees 31 20 21 A/13 20 31

2400

2400

2400

2400

2400

2400

2400

2400

2300

2200

2100

Hanger spacing

Standard lay-in installation of24 mm exposed suspensionsystem using Board orTegular edge planks.

Gen

eral

App

licat

ions

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Page 48: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

46 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

White capping 24 40 42 3600 43 16 57,60 22,20 20

Galvanised capping 24 40 42 UP 3600 43 16 57,60 23,50 20

Black capping 24 40 42 BK 3600 43 16 57,60 22,20 20

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

PRELUDE 35 XL2

Main Runners Peakform Prelude 35 XL2 (bulb-to-bulb connection)

Cross Tees Peakform Prelude 35 XL2 (stab system, override)

Section Drawings

Perimeter Trim

White capping 24 06 42 1990 43 16 31,80 12,30 2024 36 42 1500 43 32 48,00 16,60 2024 30 42 1200 43 36 43,20 14,90 6024 20 42 600 43 36 21,60 7,50 120

Galvanised capping 24 06 42 UP 1990 43 16 31,80 13,00 2024 36 42 UP 1500 43 32 48,00 17,70 2024 30 42 UP 1200 43 36 43,20 15,90 6024 20 42 UP 600 43 36 21,60 8,00 120

Black capping 24 06 42 BK 1990 43 16 31,80 12,30 2024 36 42 BK 1500 43 32 48,00 16,60 2024 30 42 BK 1200 43 36 43,20 14,90 6024 20 42 BK 600 43 36 21,60 7,50 120

T 3024 H Perimeter angle, White painted 3000 24 40 120,00 28,50 50

T 3030 H* Perimeter angle, White painted 3000 30 30 90,00 25,00 40

* Also available in Galvanised (UP) and Black (BK) Please add the corresponding suffix to the item number when placing the order.

43 mm

35 mm

43 mm

35 mm

43 mm

35 mm

3600 50 100 33 x 100 100 50Length

1200 600 600

Length

1990 / 1500 / 600

Main Runners Prelude 35

Cross Tee Prelude 35 XL2

Cross Tee Prelude 35 XL2

Cross Tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.All dimensions in millimetres. All sizes are nominal.

Gen

eral

App

licat

ions

Exposed 35 mm grid system (nominal).For use in large shed type buildings including retail outlets, industrial manufacturing and meeting halls, etc...

30

30

30

Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Page 49: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

47

Gen

eral

App

licat

ionsPRELUDE 35 XL2

Grid Load Capacities

Prelude 35 XL2 System

The following table gives the maximum permitted hanger distance (L) along the Main Runner (24 40 42).

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

4,5 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

6,5 kg/m2

7,0 kg/m2

8,0 kg/m2

9,0 kg/m2

10,0 kg/m2

12,0 kg/m2

14,0 kg/m2

Main Runner spacing 1990 mm (x 1000 mm)

1990 mm XL2 Cross Tee 24 06 42

1700

1600

1550

-

-

-

-

-

-

-

-

-

-

-

-

Main Runner spacing 1500 mm (x 1000 mm)

1500 mm XL2 Cross Tee 24 36 42

1900

1800

1700

1650

1600

1550

1500

1400

1350

1300

1250

-

-

-

-

Main Runner spacing 1200 mm (x 600 mm)

1200 mm XL2 Cross Tee 24 30 42

1900

1850

1750

1700

1650

1600

1550

1500

1500

1450

1400

1300

1250

1150

1050

Main Runner spacing 600 mm (x 600 mm)

600 mm XL2 Cross Tee 24 20 42

2000

2000

2000

2000

2000

2000

1950

1900

1900

1850

1750

1700

1650

1550

1450

Hanger spacing

Key Attributes Physical Data

• Peakform Patented universal Main Runner and Cross Tee design increase strength and stability for improved performance and makes the grid easier to cut

• Rotary stitched Main Runner and Cross Tees for additional torsional strength and extra stability during installation

• Material Double-web galvanised steel

• Surface Finish Baked polyester paint

• Product Family Exposed tee system

• Main Runner / Cross Tee Interface Joggled ends

• End Detail Main Runner : with Superlock clip, by pass coupling, single stitching Cross Tees : staked-on stab clip, double stitching

• Colour Available in White, Galvanised and Black.

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Page 50: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

48 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Gen

eral

App

licat

ions BANDRASTER

Slotted at 312,50 mm (1)36 2100 B 3750 100 8 30,00 32,60 16

Slotted at 100 mm (1) 36 3050 3600 50 8 28,80 24,00 2836 3075 3600 75 8 28,80 27,70 2036 3100* 3600 100 8 28,80 31,40 1636 3125 3600 125 8 28,80 38,30 1236 3150 3600 150 4 14,40 21,20 20

Unslotted (2) 36 0050 A 3600 50 8 28,80 24,00 2836 0075 A* 3600 75 8 28,80 27,70 2036 0100 A 3600 100 8 28,80 31,40 1636 0125 A 3600 125 8 28,80 38,30 1236 0150 3600 150 4 14,40 21,20 20

(1) Is compatible with all plank edge details whether cross tees are required or not.

(2) Is compatible with only with plank edge details when no visible cross tees span between bandraster sections.

A 36 0501 Strip / rod connector 50 50 1,20A 36 0751 75 50 1,50A 36 1001 100 50 1,80

A 36 0502 G Nonius hanger 50 100 5,80A 36 0752 G 75 100 8,10A 36 1002 G 100 100 11,00A 36 1252 G 125 100 12,50A 36 1502 G 150 100 15,00

A 36 0503 G Splice 50 100 8,00A 36 0753 G 75 100 8,30A 36 1003 G 100 100 14,00A 36 1253 G 125 100 17,00A 36 1503 G 150 100 19,50

A 36 0504 G Cross connector 50 100 5,80A 36 0754 G 75 100 8,10A 36 1004 G 100 100 11,00A 36 1254 G 125 100 12,50A 36 1504 G 150 50 7,50

A 36 0505 G Wall connector 50 100 5,80A 36 0755 G 75 100 8,10A 36 1005 G 100 100 11,00A 36 1255 G 125 100 12,50A 36 1505 G 150 50 7,50

A 36 0506 G Crossing element 50 48 7,70A 36 0756 G 75 30 5,70A 36 1006 G 100 32 7,40

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) Height (mm) pcs lm kg

Bandraster Systems

Bandraster Accessories

Item Nr. Description Dimension Content / Carton Weight / Carton height (mm) pcs kg

Product available as standard in Global White.

*Also available in RAL 9010 (WR)

36mm

12mm12mm

150 / 125 / 100 / 75 / 50mm150 / 125 / 100 / 75 / 50mm

All measurements in millimetres. All sizes are nominal.

Bandraster is a suspension system available in a wide range of widths, compatible with Prelude 24 TLX/XL2 Cross Tees.

Page 51: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

49

Gen

eral

App

licat

ionsBANDRASTER

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

Pin to connect bottom and upper part of NoniusA 10229 G(It is recommended to use 2 pins to connectbottom & upper part of Nonius)

Upper part of Nonius

Splice

Crossing element

Threaded rodA 1829 G

Wall connector

Nonius hanger

Strip / rod connector

Crossconnector

- Slotted Bandraster is compatible either with Prelude 24 XL2 or Prelude 24 TLX Cross Tees - On special request: Prelude 15 TL can be made compatible for installation with slotted Bandraster;- Special spaced slotting; minimum slot spacing is 50 mm; Maximum length of Bandraster is 5000 mm

System Drawing

Page 52: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

50 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Gen

eral

App

licat

ions

CZ 41494 H Deep Z 32 mm 1500 20 30,00 9,40CZ 41794 H Deep Z 32 mm 1800 20 36,00 11,30CZ 41795 H Deep Z 70 mm 2500 10 25,00 13,40

CA 5740 G Double height Z 4000 10 40,00 24,00

CA 5733 A Spacer bar 600/625 50 31,20 7,00

CA 5734 Spacer bar 1200/1250 50 62,50 14,00

CZ 3600 H Z section 3600 20 72,00 22,70

CA 21 G Z connector 150 500 - 10,00

CC 4000 G Channel 13 x 38 mm 4000 20 80,00 26,50C 3000 G Channel 19 x 38 mm 4000 8 32,00 23,80

CA 120 G Preformed channel clip - 100 - 0,50

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs lm kg

SYSTEM Z

CC 4000 G

CA 120 G

Semi-Concealed - Compatible with SL2

CZ 3600 H

CA 21 G

Semi-Concealed

All measurements in millimetres. All sizes are nominal.

Semi-concealed and concealed systems.Provides specialist solution for corridors giving a monolithic visual. Can also be used for room situations in conjunction with Prelude 24 and Bandraster grid.

Page 53: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

51

CA 97 G Clamp for C-channel 30 100 - 1,70

CT 600 G Noggin tee 600 100 60 8,50

CA 5730 G Anti-breather spline 295 200 - 3,80

SYSTEM Z

CC 4000 G

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs lm kg

Semi-Concealed (continued)

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

System Drawing

SL2

Quantities required per 1m2 (no waste included)

13

2 The chart is for general guidance only.

Plank size

1500 x 300 / 312,5 mm1800 x 300 / 312,5 mm2500 x 300 / 312,5 mm

Supportingsections

at

300 / 312,5 mm300 / 312,5 mm300 / 312,5 mm

Z ProfileCZ 41494 H

3,33 / 3,20 lm--

Z ProfileCZ 41794 H

-3,33/3,20 lm

-

Z Profile CZ 41795 H

--

3,33 /3,20 lm

Perimeter trim according to circumference of room Perimeter angles should be of thicker material when corridor wider than 1,80 m.

Semi-concealed SL2Corridor installation

Gen

eral

App

licat

ions

Page 54: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

52 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Gen

eral

App

licat

ions DRYWALL GRID SYSTEM

The Drywall Grid System (DGS) is a quick and easy to install suspension system for plasterboard ceilings, available in a range of two unique systems : Standard for typical flat installations and Faceted for curved and domed ceilings.

Peakform Main Runner and Superlock Clip (bulb to bulb connection)

Accessories

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) width (mm) pcs Im kg

Main Runners 7940 G slot at 150mm 3600 38 38 12 43,20 20 367942 G slot at 150mm 3000 38 38 12 36,00 17 36 7941 G slot at 100mm 3600 38 38 12 43,20 19,52 36

Faceted Main Runners HD 8906 F08 G 3658 43 38 12 43,92 22 24HD 8906 F16 G 3658 43 38 12 43,92 22 24

Cross Tees7930 G 1200 38 38 36 43,20 20 487918 900 38 38 36 33,00 15 487920 G 600 38 38 36 21,60 10 96

Unhemmed C channel7838 G 3048 (120") 40 20 60.96 16 32

Knurled angle trimKAM 12 H 3658 (12') 32 32 30 109.72 26 12

19

43

A variety of Drywall Grid accessories are available to provide problem solving solutions that save time, labour and money.

Item Nr. ImageItem Nr. Image Item Nr. Image

DWACS AGDrywall attachment clip

DW30C AG DW45C AG DW60C AG DW90C AGDrywall angle clips

RC2 AG Radius clip

MBAC AG Main Runner adapter clip

DW50 LTTransition clip13 mmplasterboard (1/2")

DW58 LTAG Transition clip for 15 mmplasterboard (5/8")

MBSC2 AGMain Runner spacer clip

XTAC AG Cross Tee adapter clip

DLCC AG Direct load ceiling clip

BP DWC AGDrywall clip

All measurements in millimetres. All sizes are nominal.

Page 55: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

53

DRYWALL GRID SYSTEM

Section Drawing

Gen

eral

App

licat

ions

Faceted Main Runners faceted at 203mm centres. Use for radius 4.50m or less

Faceted at 406mm centres. Use for radius over 4.50m (directional Main Runner)

Cross Tees

Length

7940 G 3600mm7941 G 3600mm7942 G 3000mm

HD 8906 F08 G

HD 8906 F16 G

7930 G

7920 G

7918 G

(45 slots) 3658mm

1200mm

600mm

900mm

(54 slots) 3658mm

Hanger wire or suspension angleVertical brace

Main Runner

Cross Tee

Main Runner

System Drawing

For more information, please ask for the Drywall Grid System Curved and Flat brochure.

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

75 mm50 mm75 mm

23 x 150 mm35 x 100 mm19 x 150 mm

75 mm50 mm75 mm

Page 56: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

54 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Cor

ridor DRYWALL GRID SYSTEM SHORTSPAN

System Drawing

Drywall Grid System (DGS) Shortspan product range

The Drywall Grid System (DGS) ShortSpan is a quick and easy to install suspension system forplasterboard ceilings and in particular for corridors in both commercial and residential installations.

Lockingtab

The gap between walltrim and shortspanshould not be over 3mm

LAT 12/10 Hmust be screwedto wall structure

Alignmentcrimps

Locking tabsat 150/100mmcentres.

150/100mm

S 7708 G 2438 (8') 38 12 29,26 13 24

S 7710 G 3048 (10') 38 12 36,57 17 24

S 7712 G 3658 (12') 38 12 43,89 20 24

S 7714 G 4267 (14') 38 12 51,20 23 24

LAT 12 H 3600 32 30 109,72 18 12

LAT 10 H 3600 30 30 110,00 15 12

KAM 12 B 3660 (12') 32 10 36.60 9 50

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length(mm) height (mm) pcs Im kg

Shortspan T-bars

Locking angle trimsLocking tabs at 150mm for the BP LAT 12HLocking tabs at 100mm for the BP LAT 10H

Knurled angle trim

The ShortSpan system is designed for use in drywall ceilings where the spans do not exceed 4200mm.

The individual ShortSpan tees are not designed to be used independent of the locking angle trim (LAT 12 H) or optional knurled angle trim (KAM 12 B).

For more information, please ask for the Drywall Grid System Standard and Faceted brochure.

Page 57: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

55

Universal Main Runner Prelude Sixty2 Double Peakform and Superlock Clip (bulb to bulb connection)

Cor

ridor

Planks

Perimeter trim

Double bent teebar hanger

PRELUDE SIXTY2Exposed 24 mm grid system.

Double Peakform Main Runner section requiring less suspension points and compatible with Prelude 24 XL2 and TLX Cross Tees.

System Drawing

(1) Colours available: Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Chrome (CE), White RAL 9010 (WR), Brass (BS).

Accessories

Item Nr. Description Dimensions Content / Carton Weight / Carton Length (mm) Height (mm) pcs kg

A WDN23 G Double bent tee bar hanger 57 36 100 2,30

Grid Load Capacities

Spacing (mm) 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 Prelude Sixty2 300 37,2 32,8 29,1 25,9 23,2 20,9 18,9 17,2 15,6 14,3 13,1 11,8 10,0 8,5 7,1

Butt cut 600 18,6 16,4 14,5 13,0 11,6 10,5 9,5 8,6 7,8 7,1 6,5 5,9 5,0 4,2 3,5

1200 9,3 8,2 7,3 6,5 5,8 5,2 4,7 4,3 3,9 3,5 3,2 - - - -

Span in mm - Load capacities in kg/m2

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

The Prelude Sixty2 system is designed for use in corridor applications, with or withoutCross Tees, and where spans do not exceed 3750 mm. For a wider configuration, theMain Runner is compatible with the Prelude 24 TLX and XL2 Cross Tees.

Special length and modulation made to order, with and without slots, please contactyour Armstrong Technical Sales team.

Page 58: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

56 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Spe

cific

App

licat

ions CLEAN ROOM GRID SYSTEM

Main Runner Clean Room Grid System 24

Section Drawings

Cross Tees Clean Room Grid System 24 + Perimeter Trim

Accessories

Item Nr. Dimensions Content /Carton Weight/Carton Cartons/Pallet length (mm) height (mm) pcs lm kg

EA 794044 3600 43 20 72,00 24,00 30

EA 793044 1200 43 60 72,00 26,00 20

EA 792044 600 43 60 36,00 12,00 40

EA 7801 3660 24 30 109,80 20,00 25

150 1503600 300 3009 x 300

300 300

300 300

300 3001200

600

18

12 16

CHDC Hold down clip suitable for non-magnetic areas

A 426 Board access clip

Main Runner Clean Room Grid 24

Cross Tee Clean Room Grid 24

Length

Length

Exposed 24 mm grid system (nominal). A complete system solution: Aluminium construction for maximum corrosionresistance and non-magnetic environments. Co-extruded with a unique factory applied gasket for a better seal betweentile and grid. System suitable for use in applications up to Class 4 performance as per Class ISO standard 14644-1.

All measurements in millimetres. All sizes are nominal.Please contact Armstrong Technical Sales for further details.

Page 59: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

57

Spe

cific

App

licat

ionsCLEAN ROOM GRID SYSTEM

Grid Load Capacities

Tile weight Main Runner spacing 1200 mm Main Runner spacing 600 mm 1200 mm Cross Tee 600 mm Cross Tee EA 793044 EA 792044

Clean Room Grid 24 mm The table gives the maximum permitted hanger distance (mm) along the Clean Room Grid Main Runner (EA 794044) for the tile weights and Main Runner spacings noted.

1850

1750

1700

1650

1550

1500

1450

1400

1300

1200

1050

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

7,0 kg/m2

8,5 kg/m2

10,5 kg/m2

13,0 kg/m2

2100

2100

2100

2050

1950

1900

1850

1800

1700

1600

1450

Hanger spacing

All measurements in millimetres. All sizes are nominal.Please contact Armstrong Technical Sales for further details.

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Key Attributes Physical Data

• Aluminium construction for maximum corrosion resistance and non-magnetic environments

• Unique co-extruded section aluminium based

• Unique, factory applied gasket for a better seal between tile and grid

• Staked on Main Runner splice for easy connections,

integral hook Cross Tee end detail

• Hold down clips to ensure a good seal

• System suitable for use in applications up to Class 4

performance per ISO standard 14644-1

• Material Co-Extruded Aluminium – Gasketed

• Cross Tee/Main Runner Interface Co-Extruded Aluminium Clean Room – Flush Fit

• Product family Exposed grid system

• End Detail Main Runner: Staked-on clip Cross Tee: Integral hook

Clean Room Main Runner

Clean Room Hold-down clip (CHDC)

Clean Room Cross Tee

Board Tile

Page 60: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

58 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Spe

cific

App

licat

ions PRELUDE 24 CORROSIVE RESISTANT

28 40 42 3600 43 20 72,00 21,00 3028 41 42 3750 43 20 75,00 21,90 30

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Universal Main Runners 24 Corrosive Resistant Peakform and Superlock Clip (bulb to bulb connection)

14 30 32 1200 38 60 72,00 18,20 7214 31 32 1250 38 60 75,00 18,90 72

14 20 32 600 38 60 36,00 9,10 14414 21 32 625 38 60 37,50 9,50 144

Cross Tees TLX 24 Corrosive Resistant (Hook system, butt cut)

Section Drawings

Main Runner 24 Corrosive Resistant

Cross Tee TLX 24 Corrosive Resistant Cross Tee TLX 24 Corrosive Resistant

3750 78,125 156,25 21 x 156,25 156,25 78,125 3600 50 100 33 x 100 100 50

1200 300 300 300 300

1250 312,5 312,5 312,5 312,5

600/ 625

Availability of products may vary according to location.

Length

Length

Perimeter Solution

Accessories - Corrosion resistance 700 hours salt spray test

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) height (mm) pcs Im kg

T 1924 LB Corrosive resistant 3050 24 36 109,80 27,60 perimeter angle

A WDNCR 20 H Bent tee bar hangerfor threaded rod

A CR1829 G 1000mm Threaded rod dia. 6 mm

A CR1827 G Nut for threaded rod

A CR7890 G Universal retaining clip

A CR827 G 1700 mmhanger withhook

A CR11 G Small hook

A CR12 G Butterfly

T 1924 LB Corrosiveresistant suspensionangle

Exposed 24 mm grid system (nominal).Special paint finish and TLX steel-based composite clip for enhanced corrosion resistance.Corrosion resistance 700 hours salt spray test on grids according to EN ISO 9227 standards.Durability Class C (EN13964:2004 + A1:2006)

For loading data please see standard versions of these items on pages 66-67.

Page 61: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

59

Spe

cific

App

licat

ions

Tile Main Runner Hanger Main Runner Cross Tee Cross Tee Hanger Universal centres centres 1200 mm 600 mm Retaining Clip

1200 x 600 mm 1,39 pcs

600 x 600 mm 2,78 pcs

System Drawing (module 1200 x 600 mm)

6 1 2 3 4 7

5

Standard lay-in installation of 24 mm exposed suspension system using Board or Tegular edge tiles.

The chart is for general guidance only.

Quantities required per 1m2 (no waste included)

Perimeter Trim approx. 0,70 lm/m2

1200 mm

600 mm

1200 mm

600 mm

1200 mm

1200 mm

1200 mm

1200 mm

0,84 lm

1,67 lm

0,84 lm

1,67 lm

1,67 lm

-

1,67 lm

-

-

0,84 lm

0,84 lm

1,67 lm

0,70 pcs

1,40 pcs

0,70 pcs

1,40 pcs

5,56 pcs

5,56 pcs

5,56 pcs

5,56 pcs

Grid Load Capacities

Prelude 24 Corrosive Resistant The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (28 40 42) for the tile weights and Main Runner spacings noted.

Tile weight

2,5 kg/m2

3,0 kg/m2

3,5 kg/m2

4,0 kg/m2

5,0 kg/m2

5,5 kg/m2

6,0 kg/m2

7,0 kg/m2

8,5 kg/m2

10,5 kg/m2

13,0 kg/m2

Main Runner spacing 1200 mm 1200 mm Cross Tee

14 30 32

1900

1800

1750

1700

1600

1550

1500

1450

1300

1200

1050

Main Runner spacing 600 mm 600 mm Cross Tee

14 20 32

2100

2100

2100

2100

2000

1950

1900

1800

1700

1600

1500

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

Hanger spacing

*reduce to 450 if heavy tile / overlays areused or heavy service fittings are locatednear the perimeter.

PRELUDE 24 CORROSIVE RESISTANT

1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.

2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.

3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).

4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.

5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.

6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.

Page 62: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

60 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Spe

cific

App

licat

ions SEISMIC Rx®SYSTEM

T 3024 H Perimeter angle, 3000 40 28,50 50painted

BERC2 Main Runner 50 200 9,00 36end retaining clip

SJCG Seismic joint clip - 200 7,00 36XL2 Cross Tee (24mm)

SJMR15 Seismic joint clip - 100 11,00 60Peakform Main Runner (24mm)

ES 4 Expansion sleeve (24mm) 100 100 1,00 170

442 Vector Seismic clip - 100 1,63 -

31 30 51 B(1) 1200 38 60 72,00 18,20 7231 31 51 B(1) 1250 38 60 75,00 18,90 72

31 20 21 A(1) 600 30 60 36,00 8,20 14431 21 23 A(1) 625 30 60 37,50 8,60 144

31 40 32 A(1) 3600 43 20 72,00 21,00 3031 41 33 B 3750 43 20 67,50 20,00 30

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Cross Tees Prelude 24 XL2 (stab system, override)

Accessories

Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)

Availability of products may vary according to location.

Exposed 24mm grid system (nominal).Independently tested approach using Prelude XL2 grid to achieve ceiling installations that can withstand the forcesassociated with significant seismic activity or other severe events.

Cross Tees slotted

Cross Tees unslotted

Item Nr. Description Dimensions Quantity / Carton Weight / Carton Cartons / length (mm) pcs kg Pallet

(1) Standard Colours available : BK (Black), CA (Carrara), PN (Platinum), BS (Brass), CE (Chrome), SG (RAL9006),WR (RAL 9010). A further 180 RAL colours are available as a special on request. Please contact your local sales office.

Page 63: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

Attached Wall

Una

ttac

hed

Wal

l

Unattached Wall

A A A

B

MainRunner

600mmc/c

Hanger Wire

MainRunner

B

B

B

B

B

B

B B B

B

x

x

x x

x

x

x

x

x

61

Spe

cific

App

licat

ions

System Drawing

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

SEISMIC Rx®SYSTEM

Note: some recommendations / guidelines require additional hangers onperimeter Cross Tees within 200mm of the perimeter. This is not arequirement of the Seismic Rx®solution using the BERC2 clip, butmay also be incorporated to provide additional system security in veryhigh hazard areas e.g. emergency services control centre, where fullfunctionality is planned post event.

200mm MAXTight Screw

30 mm

Attached Wall Detail

Optional Screw

200mm MAX

Unattached Wall Detail

30mm20mm

• T 3024 H perimeter trim• BERC2 on all (four) sides of room prevents ends of

Cross Tees and Main Runners from spreading apart• 20mm clearance on two adjacent sides and 10mm

overlap of grid on the perimeter trim

Page 64: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

62

Spe

cific

App

licat

ions LONGSPAN SYSTEM

LP 546 G 5000 54 5 25,00 18,40 10LP 706 G 5000 70 5 25,00 23,60 10LP 856 G 5000 85 5 25,00 25,10 10LP 120 G 6500 120 5 32,50 63,30 10

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

Primary Channels

Accessories

A 4510 G Bent hanger for T profile - 50 2,00

A 1820 G Beam flange clip 47 100 2,20A 1821 G 47 100 3,20

A B11067 G Special holding clamp* 54 100 3,10A B11066 G 70 100 4,30A B11065 G 85 100 4,60A B11064 G 120 50 3,30

A M4538 G Wall connection 54 25 1,30A M4536 G 70 25 1,70A M4534 G 85 25 3,20A M4529 G 120 25 5,90

A R4537 G Connector 54 25 1,90A R4535 G 70 25 2,30A R4533 G 85 25 4,20A R4528 G 120 25 7,00

CC 4000 G Channel 13 x 38 mm 38 20 26,50CA 120 G Preformed channel clip** - 100 0,50

Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg

85mm

120mm

40mm40mm 40mm40mm

54mm70mm

40mm40mm 40mm40mm

h

*Both Bent hanger for T profile and special holding clamp only work with threaded rod A 1829 G+ Connector A1839 G + nut (A 1827 G)**Install one clip on each side of the Channel CC 4000 GAll measurements in millimetres. All sizes are nominal.

LongSpan Grids are designed to create a primary framework underneath beams or between walls, therebyallowing the suspended ceiling Main Runners to be installed with fewer suspension points.

CC 4000 G

CA 120 G

www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Page 65: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

L O N G S PA N S Y S T E M

System Drawing

Grid Load Capacities (LongSpan System) Space 1200 mm

Note: Uniformly distributed load kg/m2.Load charges in kg/m2 for deflection L/300.

1200

1200

AM 45....Wall connector

AR 45.....Connector

A 4510 GBent hanger for T profile

A 182 ...Beam flange clip

LP...Primary channel

Note :- Two wall connectors AM 45... must be

used to fix to walls.- Two connectors AR 45... must be used

when connecting two lengths of Primary Channel together.

- Two preformed channel clips CA 120 Gmust be installed on the opposites sides ofthe Primary channel

AB 11...Special holding clamp

CC 4000 GChannel (tie bar)

Steel beam

CA 120 GPreformed channel clip

Threaded rod A 1829 G + ConnectorA 1839 G + Nut A 1827 G

Steel beam

1 tie bar 2 tie bars 3 tie barsSpacing between suspensions (m) 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50 4,75 5,00 5,50 5,75 6,00 6,50

Item Nr. LP 546 G kg/m2 48 48 32 23 16 12 9

LP 706 G kg/m2 48 34 25 19 14 11 9 7 6

LP 856 G kg/m2 48 42 25 19 15 12 10 8 7 7

LP 120 G kg/m2 48 30 24 20 17 14 12 10 9 8 6

63

Spe

cific

App

licat

ions

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

Page 66: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

64 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

White FT 2424 2500 24 10 25,00 5,50 50FT 1929 2500 29 10 25,00 5,50 50

BlackFT 2424 BK 2500 24 10 25,00 5,50 50FT 1929 BK 2500 29 10 25,00 5,50 50

Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg

FLEXIBLE PERIMETER TRIMS

Perimeter Trims

Accessory

Per

imet

er S

olut

ions

Excellent solution for finishing ceilings around columns and convex walls, easily cut and curved by hand on site.

24 mm

24 mm

29 mm

19 mm

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) height (mm) pcs kg

A WDN 23 G Double bent tee bar hanger 57 36 100 2,30

Key Attributes Physical Data

• Optimum length for most columns with a 2.5 m length

• Easy to cut and to bend to necessary radius

• Available in 2 colours (White and Black)

• 3 ply white PVC tape for a better visual

• Quick fix for columns and convex curves

• Material Steel core with PVC tape

• Product Family Perimeter Trims

• Coating PVC

• Colour Available in Global White and Black.

Page 67: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

65

Per

imet

er S

olut

ionsFLEXIBLE PERIMETER TRIMS

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

Perimeter Detailing

1 The white Flexible trim has THREE layers of white PVC coating to avoid the ‘greyish’ visual appearance between the steel supported zone ‘G’ and the PVC only zone ‘P’.

2 The Flexible trim should follow the same rule of being fixed onto the wall with 450 mm spacing.

3 These trims are considered decorative elements therefore any grid laying on them will need :

Note:These trims can be used only in curved TOE OUT ( Convex ) installations (19 x 29 section must be installed with the 29 mm face vertical).

Minimum bending radius : 200 mm.

Minimum environment temperature during the curving operation : 20ºC.

Due to the nature of the PVC coating, these trims do not exactly match our standard black & white colour and gloss.

Fire reaction classification Euroclass F (EN 13501-1) - please check local/country regulations for compliance.

450

PG

50 mm 50 mm

Pillar

A) A hanger support onto thegrid laid onto the flexible trimas close as possible from the edge of the trim.

B) Use the accessory A WDN 23 G to supportthe load above the trim.

Page 68: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

66 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Min

eral

Per

imet

er S

olut

ions

PERIMETER SOLUTIONS

T 1924 HD Perimeter angle, painted 3000 0,54 36 108,00 22,70

T 1924 CA(1) Perimeter angle, capped 3050 0,60 36 109,80 27,60

T 1924 LB Perimeter angle, 3050 0,55 36 109,80 27,60 corrosive resistant

T 1932 HA Perimeter angle, painted 3000 0,45 36 108,00 21,80

T 1919 HC Perimeter angle, painted 3000 0,45 36 108,00 19,30

T 2401 H Perimeter angle, painted heavy duty 3050 0,70 30 91,50 22,00T 2400 H Perimeter angle, painted 3050 0,60 30 91,50 20,00 intermediate duty

T 2424 HC Perimeter angle, painted 3050 0,45 36 109,80 21,60

T 3024 H Perimeter angle, painted 3000 0,45 40 120,00 28,50

T 3030 H Perimeter angle, painted 3000 0,54 30 90,00 25,00

T 1506 H Shadowline, painted 3050 0,45 36 109,80 26,30

T 1508 HB Shadowline, painted 3050 0,45 36 109,80 27,10

T 2020 HH Shadowline, painted 3000 0,65 20 60,00 27,00

7875 G Shadowline, painted, 3050 0,45 30 91,50 26,80 for Optima Vector, Ultima Vector, Dune Vector

T 2121 HG Shadowline, air circulation length 3000 0,60 25 75,00 41,20 of slot: 50 mm Distance between slots 20 mm (ca. 16% open area)

T 2040 HB C channel, painted 3050 0,45 20 61,00 18,10

T 7837 C channel, painted 3050 0,45 40 73,10 24,00

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) thickness (mm) pcs lm kg

All products standard in Global White. Other standard colours available for item numbers with index (1). See details below.(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR), Opal (OL), Brown (BN), Ivory (IY), Blue (BE), Red (RD), Green (GN). All measurements in millimetres. All sizes are nominal.

A comprehensive range of the most commonly used perimeter profiles, including shadowline, F upstands andcover plates, finished to match all Prelude 24 mm and 15 mm, Bandraster and Prelude 35 grid systems.

30

30

30

Page 69: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

67

Min

eral

Per

imet

er S

olut

ions

PERIMETER SOLUTIONSMineral suspension system.

Perimeter Detailing

Perimeter Trims

T 2040 H WR A C channel, 3050 0,50 20 61,00 18,10 colour RAL 9010

T 2040 H SG A C channel 3050 0,45 20 61,00 18,10 colour RAL 9006

T 1575 HA Unequal U-Profile, 3050 0,45 36 109,80 24,20 painted

7856 H F Upstand trim, 3050 0,45 20 61,00 23,70 painted, for 16 mm thick panels

7852 H F Upstand trim, 3050 0,45 20 61,00 23,00 painted, for 13 mm thick panels

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) thickness (mm) pcs lm kg

Standard perimeter finish with perimeter angleT 1924 HD or T 1924 CA

Perimeter finish with C channel T 2040 HA1 A 7890 G Universal retaining clip

A 1796 GPerimeter wall spring

Perimeter finish with unequal U-Profile T 1575 HAPerimeter finish with shadowline T 1506 H

24

19

25

6

15 15

ca. 300 ca. 300

ca. 300ca. 300

40

20

32

15 7,5

1

Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.

A 156 G / A 246 G Perimeter fill-in for Tegular and MicroLook tiles

Page 70: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

68 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

PERIMETER SOLUTIONS

T 2040 H WR A Perimeter channel RAL 9010 20x40 mm 3050 20 61,00 18,10

C 1803 H Perimeter wedge 200 100 - 5,00

M 215013 Perimeter trim RAL 9010 25x 25 mm 4000 10 40,00 8,00

M 215014 Shadowline RAL9010 20x20x20x25 mm 4000 10 40,00 13,50

M 215015 Shadowline RAL9010 20x15x10x25 mm 4000 10 40,00 11,00

M 311081 Cut tile spring wedge 40 100 - 0,30

Perimeter trims also available in Global White.

Perimeter Trims for Metal Ceilings

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs lm kg

Met

al P

erim

eter

Sol

utio

ns

Metal suspension system.

Page 71: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

69

Perimeter Detailing for Metal Ceilings

25

25

20

10

15 25

40

20

M 311081 – Cut tile spring wedge

M 215013 – Aluminium perimeter angle trim

T 2040 H WR APerimeter channel and perimeter wedge for cut modules

C 1803 H

M 215015 Aluminium shadowline trim

Cut Tile Spring Wedge M 311081 -1-2 pieces per 300mm of perimeter trim.

Perimeter wedge C 1803 H -1 piece per 300mm of perimeter trim.

M 311081

All measurements in millimetres. All sizes are nominal.

Met

al P

erim

eter

Sol

utio

ns

PERIMETER SOLUTIONSMetal suspension system.

Page 72: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

70 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Acc

esso

ries

ACCESSORIES

A W950 G Suspension wire dia. 2 mm ca. 200 metres 1 coil 4,70 41

A 1843 G Expanded bolt for threaded rod dia. 6 mm 25 100 0,50

A 1829 G Threaded rod dia. 6 mm 1000 50 8,50

A 1839 G Connection for threaded rod dia. 6 mm 20 100 0,60

A 1827 G Nut for threaded rod 100 0,20

A WDN20 H Bent tee bar hanger for threaded rod 57 100 1,40

20 (tested withA 14 G Universal clip 40 100 1,00 6 mm threaded rod)

A WDN21 H T bar hanger - 20 0,30 32

A WDN23 G Double bent T bar hanger with 57 100 2,30 32 2 sizes of diameter hole

A 11030 G Quick hanger - hook (2 hooks) 165-280 100 5,40

A 11020 G Quick hanger - hook (2 hooks) 215-380 100 4,10

A 11040 G Quick hanger - hook (2 hooks) 315-580 100 8,50 41

A 11070 G Quick hanger - hook (2 hooks) 415-780 100 10,50

A 11090 G Quick hanger - hook (2 hooks) 515-980 100 13,00

A 12030 G Quick hanger - eye (1 hook +1 eye) 165-280 100 5,20

A 12020 G Quick hanger - eye (1 hook +1 eye) 215-380 100 4,10

A 12040 G Quick hanger - eye (1 hook +1 eye) 315-580 100 8,30 41

A 12070 G Quick hanger - eye (1 hook +1 eye) 415-780 100 10,50

A 12090 G Quick hanger - eye (1 hook +1 eye) 515-980 100 13,00

Item Nr. Description Dimensions Content / Carton Weight / Carton Admissible Load * length (mm) pcs kg kg

Suspension & Accessories

* Note: These admissible loads have been determined from laboratory tests in accordance with EN 13964 : 2004 + A1 : 2006 and applyto the hangers and their grid connections only.No account has been taken of the strength of top fixings which must be selected as appropriate for the supporting structure andestimated load.

Page 73: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

71

Suspension & Accessories

Item Nr. Description Dimensions Content / Carton Weight / Carton Admissible Load * length (mm) pcs kg kg

* Note: These admissible loads have been determined from laboratory tests in accordance with EN 13964 : 2004 and apply to the hangers and their grid connections only.No account has been taken of the strength of top fixings which must be selected as appropriate for the supporting structure and estimated load.

Availability of products may vary according to location.All measurements in millimetres. All sizes are nominal.Please contact Armstrong Technical Sales for further details.

60

190

A 10202 H Upper part of nonius 300 100 5,10

A 10203 H Upper part of nonius 400 100 7,20

A 10204 H Upper part of nonius 500 100 9,00

A 10205 H Upper part of nonius 600 100 11,00

A 10206 H Upper part of nonius 700 100 12,80

A 10208 H Upper part of nonius 800 100 15,50

33

A 10230 G Bottom part of nonius hanger 190 100 4,30

A 10229 G Pin to connect bottom 60 100 0,80

& upper part of nonius

A 952 G Suspension angle 3600 20 13,30

A 826 G 2 m hanger with hook 2000 100 20,00

A 827 G 1,7 m hanger with hook 1700 100 20,00

A 11 G Small hook 120 100 2,00

A 12 H Butterfly 55 100 1,00

A 829 H Suspension hanger for T bar 130 100 2,80 33

ACCESSORIES

Acc

esso

ries

Page 74: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

72 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Acc

esso

ries

Suspension & Hold Down Clips

A 1837 G Rocking hanger 82 100 2,00

A 1838 G Hanger for wooden beam 148 100 3,20

A 1820 G Beam flange clip 1,6 - 4,8 mm thickness - 100 2,20

A 1821 G Beam flange clip 4,8 - 9,5 mm thickness - 100 3,20

A 1822 G Clip for quick hanger 1,6 - 4,8 mm thickness - 100 0,80

A 1823 G Clip for quick hanger 4,8 - 9,5 mm thickness - 100 3,00

A 7890 G Universal retaining clip - 100 0,40

A 819 G Locking hold down clip, for 6 - 30mm tiles 64 500 2,40 (Peakform & Square bulb)

A 1060 T35 Hold down clip for panels - 250 3,10 up to 110 mm thick

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs kg

82 10

148

18

55

38

A 1829

38

ACCESSORIES

Page 75: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

73

Hold Down Clips & Accessories

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs kg

EHDC 58 AG Exterior hold down clip 102 125 7,00

(Peakform & Square bulb)

A 7912 G Hold down clip for 40 mm soft 68 100 1,10 fibre panels

A 7902 G Hold down clip for 18-25 mm soft 40 100 1,10 fibre panels

A 426 Board access clip - 100 0,40

A 7930 G Last tile clip Tegular 40 25 0,05

A 7931 G Last tile clip MicroLook 40 25 0,05

MCC4 G Mitre closure clip for - 200 0,30 6 mm Silhouette & Microline

LFC G Peakform Corner support of lay-in light - 50 0,45 (Silhouette & Microline 15 mm grid)

A 131 G T bar saddle clip (Peakform & Square bulb) 98 100 2,70

70 102

23

66

22

50

32

38

8

424

1. 2. 3.

18

12 16

Availability of products may vary according to location. All measurements in millimetres. All sizes are nominal.Please contact Armstrong Technical Sales for further details.

Acc

esso

riesACCESSORIES

Page 76: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

74 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie

Acc

esso

ries

Perimeter Accessories

A 328 G Inside corner 19 mm 58 100 0,90

A 329 G Outside corner 19 mm 65,50 100 1,20

A 330 G Inside corner 24 mm 58 100 0,90

A 331 G Outside corner 24 mm 65,50 100 1,20

A 332 G Inside corner for shadowline T 1508 HB 72 100 1,60

A 333 G Outside corner for shadowline T 1508 HB 57,20 100 1,20

A 0415 G MicroLook border clip 19 500 0,80

A 0324 G Tegular border clip 29 500 1,20

A 156 G Perimeter fill-in for 15 mm grid - 500 0,40

A 246 G Perimeter fill-in for 24 mm grid - 500 0,50

15136

1975

75

o

2413

6

29o

15

246

6,5

Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs kg

ACCESSORIES

Page 77: CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong

WESTERN EUROPEBelgium & LuxembourgArmstrong Building Products B.V.Bureaux Commerciaux BelgiquePostbus 38034800 DV BredaNederlandTel.: (+32) 02 223 00 72Fax: (+31) 076 521 04 07e-mail: [email protected]

Germany & SwitzerlandArmstrong Building ProductsKundenserviceOffice Building QuadriumClaudius Prinsenlaan 1264818 CP BredaNiederlandeTel.: (+49) 0251 7603 210Fax: (+49) 0251 7603 593e-mail: deutsche-info@armstrong.comwww.armstrong-decken.dewww.armstrong-decken.atwww.armstrong.ch

Armstrong Metalldecken AGBreitfeldstrasse 89015 st. GallenSwitzerlandTel.: +41 (0) 71 313 63 63Fax: +41 (0) 71 313 64 00

ZentralschweizArmstrong Metalldecken AGBu� ro / Lager ZentralschweizGrossweid 9CH-6026 rainTel.: +41 (0) 41 921 63 63Fax: +41 (0) 41 921 63 80

Suisse RomandeArmstrong Plafonds Métalliques SABureau Suisse Romande3, Rue Gustave-MonynierCH-1202 GenèveTel.: +41 (0) 22 731 60 70Fax: +41 (0) 22 731 60 74

Austria/Eastern EuropeArmstrong Metalldecken GmbHBundesstrasse 70A-6830 RankweilTel.: +43 (0) 55 22 34 44-0Fax: +43 (0) 55 22 34 44-8

Armstrong Metalldecken GmbHMessendorferstrasse 6A-8041 GrazTel.: +43 (0) 31 64 71 584Fax: +43 (0) 31 64 71 584-10

SpainArmstrong Building ProductsOficina de ventas EspañaImmeuble Paryseine3 Allée de la Seine94854 Ivry-sur-SeineFranciaTel.: (+ 34) 91 642 04 9900 800 90 21 03 68Fax: (+33) 1 4521 04 11e-mail: [email protected]/techos

PortugalArmstrong Floor ProductRua de Manuel Assunçao de Falcao, 634475-041 Santa Maria de Avioso - MaiaPortugalTel.: (+351) 22 982 81 10Fax: (+351) 22 982 81 19e-mail: [email protected]

France & French Speaking AfricaArmstrong Building Products SASBureaux Commerciaux FranceImmeuble Paryseine3 Allée de la Seine94854 Ivry-sur-seineTel.: 0800 41 36 43Fax: (+33) 1 45 21 04 11e-mail: [email protected]/plafonds

Siège socialArmstrong Building Products SAS67 Rue de SalinsBp 8925300 PontarlierFrance

Italy & GreeceArmstrong Building ProductsUfficio Commerciale ItaliaImmeuble Paryseine3 Allée de la Seine94854 Ivry-sur-SeineFranciaTel.: (+39) 02 66 22 76 50Fax: (+39) 02 66 20 14 27e-mail: [email protected]

NetherlandsArmstrong Building Products B.V.Verkoopkantoor NederlandPostbus 38034800 DV BredaNederlandTel.: (+31) 076 52 30 200Fax: (+31) 076 521 04 07e-mail: [email protected]/plafonds

United KingdomArmstrong World Industries LtdBuilding Products DivisionArmstrong House38 Market Squareuxbridge UB8 1NGTel.: 0800 371849Fax: (+44) 1895 274287e-mail: [email protected]

Republic of IrelandArmstrong World Industries Ltd.108 Greenlea RoadTerenureCo Dublin 6WIrelandTel.: 1800 409002Tel.: (+353) 1 499 1701Fax: (+353) 1 490 7061e mail: [email protected]

MIDDLE EAST /AFRICA / TURKEYArmstrong World Industries LtdAfrica Middle East Turkey DivisionArmstrong House38 Market SquareUxbridge UB8 1NGTel.: (+44) 01895 251122Fax: (+44) 01895 272928e-mail: [email protected]ël: www.armstrong.co.ilSouth Africa: www.armstrong-ceilings.co.za

Dubai | United Arab EmiratesArmstrong World Industries JLTOffice No. 2003, 20th FloorGold Crest Executive TowerJumeirah Lakes TowersP.O. Box 73831Dubai, [email protected]

Tu� rkiyeArmstrong Europa GmbHTu� rkiye Satış TemsilciliğiSarıyer-IstanbulTu� rkiyeGsm: +90 533 367 54 89Fax: +90 212 257 44 [email protected]

CENTRALEUROPE NORTH(DK/EE/FIN/IS/LT/LV/N/PL/S)Armstrong Building Products BVSp. z o.o. Oddział w Polsceul. Domaniewska 3702-672 WarszawaPolandTel.: (+48) 0 22 337 86 10/ 86 11Fax: (+48) 0 22 337 86 12e-mail: [email protected]: www.armstrong.lvLithuania: www.armstrong.ltNorway: www.armstrong.noPoland: www.armstrong.plSweden: www.armstrong.se

CENTRALEUROPE SOUTH(AL/BA/BG/CZ/HR/HU/KO/MD/ME/MK/RO/RS/SK/SI)Armstrong Building ProductsLighthouse Building,Jankovcova 1569/2c,170 00 Praha 7,Czech RepublicTel. : +420 234 700 543e-mail: [email protected] republic: www.armstrong.czHungary: www.armstrong.co.huRomania: www.armstrong.roSerbia: www.armstrong.rsSlovakia: www.armstrong.skSlovenia: www.armstrong.si

EASTERN EUROPECISArmstrong Moscow GmbHPark Place, office E502# 113/1, Leninsky ProspektMoscow 117198RussiaTel.: (+7) 495 956 5100Fax: (+7) 495 956 5101e-mail: [email protected] Federation: www.armstrong.ru

All photographic and design elements supplied in this brochure do not necessarily reflect any recommendation by any of the companies named in this brochureas to the proper use or recommended methods of installation of suspended ceilings and are supplied only as informative material. For technical reasons inprinting, differences may appear between colours printed in this brochure and the actual product. The choice of colours should always be made from a sampleof the product. All statements and technical information contained in this brochure, or any publication of the companies named in this brochure, relating toArmstrong ceilings are based on results obtained under laboratory test conditions. It is the responsibility of the user to verify with the seller of the products inwriting that such statements and information are appropriate to the specific use intended. Sales of the products and liability of the selling companies are inaccordance with the terms and conditions of sale of the selling company. All product specifications are subject to modifications without prior notice.

Advisory note

www.armstrong-ceilings.co.ukwww.armstrong-ceilings.ie

UK Colour Info_Layout 1 15/11/2012 10:39 Page 3