Ceiling Type - CarrierYOUR CARRIER MAN : DI/04/15 th th Comfort Inverter Allows step-less regulation...

6
Ceiling Type 4-way Cassette Type Duct Type

Transcript of Ceiling Type - CarrierYOUR CARRIER MAN : DI/04/15 th th Comfort Inverter Allows step-less regulation...

Page 1: Ceiling Type - CarrierYOUR CARRIER MAN : DI/04/15 th th Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves

Ceiling Type

4-wayCassette Type

Duct Type

Page 2: Ceiling Type - CarrierYOUR CARRIER MAN : DI/04/15 th th Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves

Bat wing fan

Wide-flow grille

DC twin rotary

New development for high-pressure low-volume fan.

Optimizing ventilation performance,

A low minimum speed of 10 rps has been achieved.

Large-area magnet

Rotor with slit

Newly designed compression

More precise components

The structure and shape of eachcompressor component has beenoptimised. The area of the rotor magnet has been increased and a slit introduced to the design. These improvements have further

noise.

ECO-driving DC twin rotary

Light CommercialThe Toshiba Digital Inverter series air conditioners combine economy and ecology in

business environment. A complete range of indoor units: Cassette, Ducted, and Under Ceiling units.

comfort and convenience to any

DC fan motor

Heat-transfer tube with improved heat-transfer High power motor

Vector-controlled inverter

High efficiency heat-transfer (flat fin)

Vector IPDU control changes the motor current wave to a smooth sine pattern so that noise emitted from the driveunits is greatly reduced. A low minimum speed of 10 rps has been

achieved.

An ozone layer depletion coefficient of zero has become absolutely essential for an advanced air conditioning system.

R410A refrigerant

Operation in Power Save Mode enables power peaks to be cut.

Page 3: Ceiling Type - CarrierYOUR CARRIER MAN : DI/04/15 th th Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves

Reduces installation spaces and enables a more efficient use of the site. Easy to install the outdoor units on a double-decked and easy to install on a wall.

Easy and safty operation for maintenance of the outdoor unit.

Inspection window makes it easy to find switch that requires operation and reduces the risk of electrical

2,3 HP 4,5 HP

Cover

Inspection window

Maintenance Switch (2 tact switches)

Maintenance light

Current model

New model

Self-Clean operation-Continuing high performance for energy saving

Small compact size chassis

This enables the 4-Way Cassette type and Ceiling type to maintain energy efficiency at the time of

propagation of mold.

Self-Clean Operation - The mechanism of the wash-off1. The aqua resin coating prevents dirt from sticking to the fins.

2. The condensation water flows and washes away dirt.3. After washing, a drying operation suppresses the

purchase for a long time.

Toshiba solutionsToshiba offers a solution for all applications: residential, light commercial and larger commercial buildings. For small commercial premises, products are designed to deliver top performance combined with energy efficiency.

Quiet operation

less, operates at under 45 db. It’s possible to automatically Low-noise design. If the outdoor temperature is 30°C or

Compatible with pipes up to 50 meters long with

Page 4: Ceiling Type - CarrierYOUR CARRIER MAN : DI/04/15 th th Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves

Smooth Curve for pliant Shape

All-new chassis and new rounded design, This new models have been developed in response to customers’ needs for ceiling unitsthat better match their room interiors.

Ceiling type

Smooth curve design & Low noise level

New Designed Wide Flap

The new air oulet has realized both High noise reduction and large air volume.

Flap control

the most suitable setting according to your cooling or heating needs, and an automatic

areas of the room to create a comfortable ambience.

Ceiling type Digital Inverter

Previous model New model

Comfortable ambience

New fan has adopted the turbulence prevention rib to optimize the ventilating way. Air volume has increased and noise level also has decreased compared with previous model. Winds of new ceiling type of 4HP to 5HP can be reached up to 4.3 metre.

Comfort

InverterAllows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves comfort.

Auto-turn Louvre

Air outlet grilles move automatically to fill every corner of the room with warm or cool air.

Automatic Air Volume controlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Medium and Low.

Long-life Filter

Built-in long-life filter makes maintenance easier.

RBC-AMT32E RBC-AX33CEWired remote controller Wireless remote controller

Remark : Cooling capacity test condition : Indoor Temp 27oCdb/19

oCwb; Outdoor Temp 35

oCdb/24

oCwb

Heating capacity test condition : Indoor Temp 20oCdb/- ; Outdoor Temp 7

oCdb/6

oCwb

Specification ( )

Model Name ( ) Indoor Unit ( )

Outdoor Unit ( )

Power Supply ( )

Refrigerant ( )

Operating Hz Min Rate Max Min Rate Max Min Rate Max Min Rate Max

Cooling Mode Cooling Capacity Kw. 1.5 5.3 5.6 1.5 7.0 7.4 3.0 10.0 11.2 3.0 12.1 13.2

( ) Btu/hr. 5,100 18,100 19,100 5,100 23,900 25,200 10,200 34,100 38,200 10,200 41,300 45,000

Operating Current ( ) Amp. 1.80 8.57 9.00 1.80 11.50 12.80 3.70 16.50 19.60 3.70 21.30 24.30

Power Consumption ( ) Kw. 0.29 1.83 1.95 0.29 2.45 2.76 0.60 3.41 4.10 0.60 4.42 5.08

Efficiency ( ) -SEER. Btu/hr./Watt 14.80 14.54 14.94 13.43

Heating Mode Heating Capacity Kw. 1.5 5.3 6.3 1.5 7.7 9.0 3.0 11.2 12.5 3.0 12.8 16.0

( ) Btu/hr. 5,100 18,100 21,500 5,100 26,300 30,700 10,200 38,200 42,600 10,200 43,700 54,600

Operating Current ( ) Amp. 1.80 6.37 11.08 1.80 9.98 14.84 3.70 14.22 19.60 3.70 16.59 22.00

Power Consumption ( ) Kw. 0.29 1.36 2.40 0.29 2.13 3.20 0.60 2.94 4.10 0.60 3.43 4.60

Efficiency ( ) -SEER. Btu/hr./Watt

096x6851x532.mm)DxWxH( noisnemiDtinU roodnI

( .gkthgieW teN)

Standard air flow (H/M/L) cfm

Sound Pressure Level (H/M/L) dB(A)

Air filter

.mm.D.O nairD

023x009x098.mm)DxWxH( noisnemiDtinU roodtuO

( .gkthgieW teN)

Noise Level ( ) - Cooling / Heatin dB(A)

Pipe Length Minimum Length m

( ) Maximum Length m

Maximum Height m

Chargeless Length m 20(Over 20m. Need to extra charge 20g/m.) 30(Over 30m. Need to extra charge 40g/m.)

Flare connection Liquid / Gas mm.(Inch.)

Operating Range (0C)

5392

530/430/320 830/590/450

235x950x690 235x1269x690

RAV-SM1107CTP-T RAV-SM1407CTP-T

RAV-SM1104ATP-T RAV-SM1404ATP-T

Under Ceiling

1Phase 220V 50Hz

RAV-SM567CTP-T RAV-SM807CTP-T

RAV-SM564ATP-T RAV-SM804ATP-T

46 / 48 48 / 52 53 / 54 54 / 55

37/36/28 41/36/29 44/38/32 46/41/35

864404

Standard filter (Long life filter)

30

1100/800/610 1210/910/710

R-410a

550x780x290

23

(-15) - 46

5

6.4 (1/4") / 12.7 (1/2") 9.5 (3/8") / 15.9 (5/8")

0503

30

Operativity

Filter Sign

Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter.

Limit Timer

Uses a 168-hour timer with three modes - “ON timer”, “OFF timer” and “Repeat OFF timer”.

17.09 15.85 16.69 16.36

Page 5: Ceiling Type - CarrierYOUR CARRIER MAN : DI/04/15 th th Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves

(3) Turn-around swing

Comfort

InverterAllows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves comfort.

.

Auto-turn Louvre

Air outlet grilles move automatically to fill every corner of the room with warm or cool air.

Automatic Air Volume controlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Medium and Low.

Long-life Filter

Built-in long-life filter makes maintenance easier.

Operativity

Filter Sign

Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter.

Limit Timer

Uses a 168-hour timer with three modes - “ON timer”, “OFF timer” and “Repeat OFF timer”.

Multi-louver individual control

The angles of each louver can be set individually in 3 different choices of swing patterns; Standard swing, Diagonally opposite swing and Turn-around swing

(1) Standard swing (2) Diagonally opposite swing

4-Way Cassette type and Digital Inverter

Individual louver control enables airflow to be chosen according to user preferences.

RBC-AMT32EWired remote controller

RBC-AX32U(W)-EWireless remote controller

Remark : Cooling capacity test condition : Indoor Temp 27oCdb/19

oCwb; Outdoor Temp 35

oCdb/24

oCwb

Heating capacity test condition : Indoor Temp 20oCdb/- ; Outdoor Temp 7

oCdb/6

oCwb

Specification ( )

Model Name ( ) Indoor Unit ( )

Outdoor Unit ( )

Power Supply ( )

Refrigerant ( )

Operating Hz Min Rate Max Min Rate Max Min Rate Max Min Rate Max

Cooling Mode Cooling Capacity Kw. 1.5 5.3 5.6 1.5 7.0 8.0 3.0 10.0 11.2 3.0 12.1 13.2

( ) Btu/hr. 5,100 18,100 19,100 5,100 23,900 27,300 10,200 34,100 38,200 10,200 41,300 45,000

Operating Current ( ) Amp. 1.60 7.70 8.63 1.60 11.40 13.10 3.69 14.40 19.62 3.69 21.20 22.55

Power Consumption ( ) Kw. 0.26 1.64 1.86 0.26 2.43 2.82 0.60 2.98 4.10 0.60 4.40 4.98

Efficiency ( ) -SEER. Btu/hr./Watt 16.52 14.73 17.15 14.02

Heating Mode Heating Capacity Kw. 1.5 5.3 6.3 1.5 7.7 9.0 3.0 11.2 13.0 3.0 12.8 16.0

( ) Btu/hr. 5,100 18,100 21,500 5,100 26,300 30,700 10,200 38,200 42,600 10,200 43,700 54,600

Operating Current ( ) Amp. 1.60 6.37 9.65 1.60 9.98 14.08 3.69 14.17 20.58 3.69 16.44 20.38

Power Consumption ( ) Kw. 0.26 1.36 2.08 0.26 2.13 3.03 0.60 2.93 4.30 0.60 3.40 4.50

Efficiency ( ) -SEER. Btu/hr./Watt 17.09 15.85 16.74 16.51

Indoor Unit Dimension Housing mm.

( ) (HxWxD) Ceiling panel mm.

.gkthgieW teN

Standard air flow (H/M/L) cfm

Sound Pressure Level (H/M/L) dB(A)

Air filter

.mm.D.O nairD

Outdoor Unit Dimension (HxWxD) mm.

( .gkthgieW teN)

Noise Level ( ) - Cooling / Heatin dB(A)

Pipe Length Minimum Length m

( ) Maximum Length m

Maximum Height m

Chargeless Length m 20(Over 20m. Need to extra charge 20g/m.) 30(Over 30m. Need to extra charge 40g/m.)

Flare connection Liquid / Gas mm.(Inch.)

Operating Range (0C)

28

4-Way Cassette

RAV-SM564UTP-T RAV-SM804UTP-T RAV-SM1104UTP-T RAV-SM1404UTP-T

24

32/29/28 35/31/28 43/38/33 44/38/34

864404

319x840x840

RAV-SM564ATP-T RAV-SM804ATP-T RAV-SM1104ATP-T RAV-SM1404ATP-T

023x009x098092x087x055

Standard filter (Long life filter)

30

1Phase 220V 50Hz

R-410a

620/520/460 730/570/480 1190/850/690 1240/850/730

30x950x950

256x840x840

46 / 48 48 / 52 53 / 54 54 / 55

6.4 (1/4") / 12.7 (1/2") 9.5 (3/8") / 15.9 (5/8")

(-15) - 46

5

0503

30

Page 6: Ceiling Type - CarrierYOUR CARRIER MAN : DI/04/15 th th Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves

YOUR CARRIER MAN :

DI/04/15

th th

Comfort

InverterAllows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves comfort.

Long-life Filter

Built-in long-life filter makes maintenance easier.

OperativityFilter Sign

Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter.

Limit Timer

Uses a 168-hour timer with three modes - “ON timer”, “OFF timer” and “Repeat OFF timer”.

Standard Duct type and Digital Inverter

Automatic Air Volume controlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Medium and Low.

Standard Duct type

Wide range of application opportunities

Compact sizing

installation opportunities to customer.

Compact size especially in height (275 mm), new slimmer chassis offers wide range of

275mm275mm

Built-in High-lift drain pump

that raises the drain piping up to 60 cm from the drain port.

The flexible piping layout is made possible by an optionally available drain-pump kit

RBC-AMT32E

Wired remote controller

TCB-AX32E2

Wireless remote controller

Remark : Cooling capacity test condition : Indoor Temp 27oCdb/19

oCwb; Outdoor Temp 35

oCdb/24

oCwb

Heating capacity test condition : Indoor Temp 20oCdb/- ; Outdoor Temp 7

oCdb/6

oCwb

Specification ( )

Model Name ( ) Indoor Unit ( )

Outdoor Unit ( )

Power Supply ( )

Refrigerant ( )

Operating Hz Min Rate Max Min Rate Max Min Rate Max Min Rate Max

Cooling Mode Cooling Capacity Kw. 1.5 5.3 5.6 1.5 7.0 7.4 3.0 10.5 11.2 3.0 12.5 13.2

( ) Btu/hr. 5,100 18,100 19,100 5,100 23,900 25,200 10,200 35,800 38,200 10,200 42,600 45,000

Operating Current ( ) Amp. 1.90 8.70 9.50 1.90 11.50 12.80 3.70 17.40 21.55 3.70 23.10 24.30

Power Consumption ( ) Kw. 0.31 1.85 2.05 0.31 2.46 2.76 0.60 3.60 4.50 0.60 4.78 4.78

Efficiency ( ) -SEER. Btu/hr./Watt 14.88 14.92 15.97 14.42

Heating Mode Heating Capacity Kw. 1.5 5.3 6.3 1.5 7.7 9.0 3.0 11.2 12.5 3.0 12.8 16.0

( ) Btu/hr. 5,100 18,100 21,500 5,100 26,300 30,700 10,200 38,200 42,600 10,200 43,700 54,600

Operating Current ( ) Amp. 1.90 7.59 11.45 1.90 10.87 14.75 3.70 14.46 19.16 3.70 17.17 23.13

Power Consumption ( ) Kw. 0.31 1.62 2.47 0.31 2.32 3.18 0.60 2.99 4.00 0.60 3.55 4.55

Efficiency ( ) -SEER. Btu/hr./Watt 14.35 14.56 16.40 15.80

Indoor Unit Dimension (HxWxD) mm.

( .gkthgieW teN)

Standard air flow (H/M/L) cfm

Sound Pressure Level dB(A)

Air filter

.mm.D.O nairD

Outdoor Unit Dimension (HxWxD) mm.

( .gkthgieW teN)

Noise Level ( ) - Cooling / Heatin dB(A)

Pipe Length Minimum Length m

( ) Maximum Length m

Maximum Height m

Chargeless Length m 20(Over 20m. Need to extra charge 20g/m.) 30(Over 30m. Need to extra charge 40g/m.)

Flare connection Liquid / Gas mm.(Inch.)

Operating Range (0C)

RAV-SM1104ATP-T RAV-SM1404ATP-T

40

1Phase 220V 50Hz

R-410a

1240/980/750

32/29/25 34/30/26 40/36/33 40/36/33

275x1400x750275x700x750 275x1000x750

23 30

Standard DuctRAV-SM566BTP-T RAV-SM806BTP-T RAV-SM1106BTP-T RAV-SM1406BTP-T

RAV-SM564ATP-T RAV-SM804ATP-T

30

480/380/290 710/550/430

023x009x098092x087x055

(-15) - 46

0503

6.4 (1/4") / 12.7 (1/2") 9.5 (3/8") / 15.9 (5/8")

Standard filter (Long life filter)

5

46 / 48 48 / 52 53 / 54 54 / 55

864404

1240/980/750

30