CE1.11 - 22x34 - City of Thornton Official Website no. drawn by: date: job #: designed by: checked...

2
SHEET NO. DRAWN BY: DATE: JOB #: DESIGNED BY: CHECKED BY: NO. DATE DES'D REVISION DESCRIPTION D'WN SCHOOL DISTRICT 27J - HIGH SCHOOL #3 2071c CONSTRUCTION PLANS - ONSITE 4/8/2016 C JVA INC JVA, Incorporated 1319 Spruce Street Boulder, CO 80302 Phone: 303.444.1951 www.jvajva.com E-mail: [email protected] CONSULTING ENGINEERS THORNTON, COLORADO KAT JPC XT UTILITY PLAN C2.0 J:\2071c\Drawings\2071c-C2.0.dwg, 4/8/2016 1:10:36 PM

Transcript of CE1.11 - 22x34 - City of Thornton Official Website no. drawn by: date: job #: designed by: checked...

SHEET NO.

DRAWN BY:

DATE:

JOB #:

DESIGNED BY:

CHECKED BY:

NO

.D

AT

ED

ES

'D

RE

VIS

IO

N D

ES

CR

IP

TIO

ND

'W

N

SC

HO

OL D

IS

TR

IC

T 27J - H

IG

H S

CH

OO

L #3

2071c

CO

NS

TR

UC

TIO

N P

LA

NS

- O

NS

IT

E

4/8/2016

C JVA INC

JVA, Incorporated 1319 Spruce Street

Boulder, CO 80302 Phone: 303.444.1951

www.jvajva.com E-mail: [email protected]

CONSULTING ENGINEERS

TH

OR

NT

ON

, C

OLO

RA

DO

KAT

JPC

XT

UT

ILIT

Y P

LA

N

C2.0

J:\2071c\Drawings\2071c-C2.0.dwg, 4/8/2016 1:10:36 PM

AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
HIGH SCHOOL NO. 3 FFE 5102.50 (ARCH 100'-00")
AutoCAD SHX Text
10" PVC WATER LINE (SEE SHEET C2.5 FOR WATER MAIN LOOP; TYP)
AutoCAD SHX Text
OIL TANK
AutoCAD SHX Text
OIL TANK
AutoCAD SHX Text
OIL WELL
AutoCAD SHX Text
OIL PIPELINE IS NOT LOCATABLE LINEWORK IS REFERENCE ONLY
AutoCAD SHX Text
OIL PIPELINE IS NOT LOCATABLE LINEWORK IS REFERENCE ONLY
AutoCAD SHX Text
MATCHLINE SEE SHEET C2.1C2.1
AutoCAD SHX Text
SANITARY LINE B SEE SHEET C2.3C2.3
AutoCAD SHX Text
SANITARY LINE A SEE SHEET C2.2C2.2
AutoCAD SHX Text
111 LF 4" C900 PVC
AutoCAD SHX Text
120 LF 6" DIP
AutoCAD SHX Text
4" WATER METER PER CITY STANDARDS
AutoCAD SHX Text
EMERGENCY GENERATOR AND PAD (RE: MEP)
AutoCAD SHX Text
FIRE DEPT CONNECTION (RE: MEP)
AutoCAD SHX Text
TWO - 2" WATER METERS PER CITY STANDARDS
AutoCAD SHX Text
144 LF 2" TYPE K COPPER
AutoCAD SHX Text
CHILLER UNIT
AutoCAD SHX Text
UTIL CROSSING
AutoCAD SHX Text
10" PVC WATER LINE (SEE SHEETS C2.5-C2.11 FOR WATER MAIN LOOP; TYP)
AutoCAD SHX Text
10" PVC WATER LINE (SEE SHEETS C2.5-C2.11 FOR WATER MAIN LOOP; TYP)
AutoCAD SHX Text
0
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
80
AutoCAD SHX Text
WORK SHALL BE CONSTRUCTED TO CITY OF THORNTON STANDARDS AND STANDARDS AND SPECIFICATIONS. THIS APPROVAL IS FOR CONFORMANCE TO THESE . THIS APPROVAL IS FOR CONFORMANCE TO THESE STANDARDS AND SPECIFICATIONS AND OTHER CITY REQUIREMENTS. THE AND OTHER CITY REQUIREMENTS. THE DESIGN AND CONCEPT REMAINS THE RESPONSIBILITY OF THE PROFESSIONAL ENGINEER OR LANDSCAPE PROFESSIONAL.
dbiro
Line
dbiro
Text Box
FH
dbiro
Text Box
FH
dbiro
Line
dbiro
Callout
Install fire hydrant
dbiro
Callout
Relocate fire hydrant
dbiro
Callout
Relocate FDC based on equipment to be installed in front
WDD
Callout
added to plans
WDD
Callout
added to plans
WDD
Callout
FDC HAS BEEN RELOCATED

SHEET NO.

DRAWN BY:

DATE:

JOB #:

DESIGNED BY:

CHECKED BY:

NO

.D

AT

ED

ES

'D

RE

VIS

IO

N D

ES

CR

IP

TIO

ND

'W

N

SC

HO

OL D

IS

TR

IC

T 27J - H

IG

H S

CH

OO

L #3

2071c

CO

NS

TR

UC

TIO

N P

LA

NS

- O

NS

IT

E

4/8/2016

C JVA INC

JVA, Incorporated 1319 Spruce Street

Boulder, CO 80302 Phone: 303.444.1951

www.jvajva.com E-mail: [email protected]

CONSULTING ENGINEERS

TH

OR

NT

ON

, C

OLO

RA

DO

KAT

JPC

XT

UT

ILIT

Y P

LA

N

C2.1

J:\2071c\Drawings\2071c-C2.0.dwg, 4/8/2016 1:10:46 PM

AutoCAD SHX Text
M
AutoCAD SHX Text
FFE 5093.00
AutoCAD SHX Text
FFE 5093.00
AutoCAD SHX Text
STORM (SEE SHEET C1.0, TYP)
AutoCAD SHX Text
OIL WELL
AutoCAD SHX Text
OIL PIPELINE IS NOT LOCATABLE LINEWORK IS REFERENCE ONLY
AutoCAD SHX Text
APPELHANZ SUBDIVISION LLC REC. NO. 2008000018004 UNPLATTED
AutoCAD SHX Text
MATCHLINE SEE SHEET C2.0C2.0
AutoCAD SHX Text
SANITARY LINE A SEE SHEET C2.2C2.2
AutoCAD SHX Text
SANITARY LINE E SEE SHEET C2.4C2.4
AutoCAD SHX Text
FIRE HYDRANT ASSEMBLY SEE SHEET C5.4 (TYP)
AutoCAD SHX Text
2" WATER METER PER CITY STANDARDS
AutoCAD SHX Text
IRRIGATION SVC (RE:LSCAPE)
AutoCAD SHX Text
144 LF 2" TYPE K COPPER
AutoCAD SHX Text
432 LF 2" TYPE K COPPER
AutoCAD SHX Text
2" DOMW SVC BLDG CONNECTION (RE: MEP)
AutoCAD SHX Text
2" DOMW SVC BLDG CONNECTION (RE: MEP)
AutoCAD SHX Text
UTIL CROSSING
AutoCAD SHX Text
UTIL CROSSING
AutoCAD SHX Text
UTIL CROSSING
AutoCAD SHX Text
UTIL CROSSING
AutoCAD SHX Text
10" PVC WATER LINE (SEE SHEETS C2.5-C2.11 FOR WATER MAIN LOOP; TYP)
AutoCAD SHX Text
1
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
1
AutoCAD SHX Text
0
AutoCAD SHX Text
2
AutoCAD SHX Text
0
AutoCAD SHX Text
3
AutoCAD SHX Text
0
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
0
AutoCAD SHX Text
4
AutoCAD SHX Text
0
AutoCAD SHX Text
3
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
2
AutoCAD SHX Text
0
AutoCAD SHX Text
1
AutoCAD SHX Text
0
AutoCAD SHX Text
1
AutoCAD SHX Text
0
AutoCAD SHX Text
2
AutoCAD SHX Text
0
AutoCAD SHX Text
3
AutoCAD SHX Text
0
AutoCAD SHX Text
4
AutoCAD SHX Text
0
AutoCAD SHX Text
5
AutoCAD SHX Text
0
AutoCAD SHX Text
4
AutoCAD SHX Text
0
AutoCAD SHX Text
3
AutoCAD SHX Text
0
AutoCAD SHX Text
2
AutoCAD SHX Text
0
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
80
AutoCAD SHX Text
WORK SHALL BE CONSTRUCTED TO CITY OF THORNTON STANDARDS AND STANDARDS AND SPECIFICATIONS. THIS APPROVAL IS FOR CONFORMANCE TO THESE . THIS APPROVAL IS FOR CONFORMANCE TO THESE STANDARDS AND SPECIFICATIONS AND OTHER CITY REQUIREMENTS. THE AND OTHER CITY REQUIREMENTS. THE DESIGN AND CONCEPT REMAINS THE RESPONSIBILITY OF THE PROFESSIONAL ENGINEER OR LANDSCAPE PROFESSIONAL.
dbiro
Text Box
FH
dbiro
Callout
Install fire hydrant
WDD
Callout
added to plans