CDISC FDA Electronic Submission

34
www.cytel. com CDISC Electronic Submission Kevin Lee JSM August 6th, 2013 1

description

The presentation is intended for those who need to prepare CDISC electronic submission to agency. The paper will discuss why we need to understand CDISC electronic submission. It will explain the significant regulatory changes lately such as FDASIA and PDUFA V. It will also discuss how to prepare CDISC electronic submission such as eCTD and FDA CDER Data Standard Strategy and finally what to prepare for CDISC electronic submission such as CSR, Protocol, SAP, SDTM annotated eCRF, SDTM datasets, ADaM datasets, ADaM datasets SAS Programs and Define.xml and their formats.

Transcript of CDISC FDA Electronic Submission

Page 1: CDISC FDA Electronic Submission

www.cytel.com

CDISC Electronic SubmissionKevin Lee

JSM August 6th, 2013

1

Page 2: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Disclaimer

2

Any views or opinions presented in this presentation are solely those of the author and do not necessarily represent those of the company.

Page 3: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Why?

3

Page 4: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Golden Rule by Simon Sinek

4

What

How

Why

Page 5: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Agenda

5

• Why do we care CDISC electronic submission? – Recent Regulatory changes

– FDASIA and PDUFA V

• How can we prepare CDISC electronic submission?– eCTD version 3.2.2 and Data Standard Strategy

• What do we prepare CDISC electronic submission?– CDISC components

– CDISC electronic submission

• Conclusion

• Questions & Answers

Page 6: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Current Status of eSubmission in FDA

6

Page 7: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Current Status in CDISC Submission

7

CDISC submission• In 2010, CDER received an average of over 650

datasets/week, with 23% of active NDAs containing CDISC/SDTM data

• In 2011 this number has increased to an average 39% in SDTM and 32% in ADaM

Page 8: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Significant Regulatory Changes

8

FDA Safety and Innovation Act (FDASIA)

• signed into law on July 9, 2012. • expands the FDA’s authorities and

strengthens the agency's ability to safeguard and advance public health.

• Main impacts for us - reauthorizes the fifth instance of Prescription Drug User Fee Act (PDUFA V)

Page 9: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

PDUFA V commitment by FDASIA

9

• Provides FDA with the necessary resources to maintain a predictable and efficient review process for human drug and biologic products.

• FDA will continue to receive a source of stable and consistent funding during fiscal years 2013-2017 that will allow the agency to fulfill its mission to protect and promote public health by helping to bring to market critical new medicines for patients

Page 10: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

PDUFA V commitment in section 7

10

A. To enhance the quality and efficiency of FDA’s review of NDAs, BLAs, and INDs, FDA shall consult with stakeholders, including pharmaceutical manufacturers and other research sponsors, to issue draft guidance on the standards and format of electronic submission of applications by December 31, 2012.

B. FDA will issue final guidance no later than 12 months from the close of the public comment period on the draft guidance. Such final guidance and any subsequent revisions to the final guidance shall be binding on sponsors, applicants, and manufacturers no earlier than twenty-four months after issuance of the final guidance.

Page 11: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

PDUFA V commitment in section 7 (2)

11

C. Requirements for electronic submission shall be phased in according to the following schedule:1. Twenty-four (24) months after publication of the

final guidance: All new original NDA and BLA submissions, all new NDA and BLA efficacy supplements and amendments, all new NDA and BLA labeling supplements and amendments, all new manufacturing supplements and amendments, and all other new NDA submissions.

2. Thirty-six (36) months after publication of the final guidance: All original commercial INDs and amendments

Page 12: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

PDUFA V commitment in section 7 (3)

12

D. ….., initial FDA guidance shall specify the format of electronic submission of applications using eCTD version 3.2.2 unless, after notice and an opportunity for stakeholder comment, FDA determines that another version will provide for more efficient and effective applicant submission or FDA review.

Page 13: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

PDUFA V commitment in section 7 (4)

13

E. Clinical Terminology Standards: …., FDA shall develop standardized clinical data terminology through open standards development organizations (i.e., the Clinical Data Interchange Standards Consortium (CDISC)) with the goal of completing clinical data terminology and detailed implementation guides by FY 2017.

1. FDA shall develop a project plan for distinct therapeutic indications, prioritizing clinical terminology standards development within and across review divisions.

Page 14: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

More Updates from FDA on DIA 2013

14

• FDA is currently developing eCTD v 4.0.• Implementation Target – Mandatory eCTD submission

– NDA and BLA : March 2016– Commercial INDs : March 2017

• Based on the current implementation schedule, FDA begins receiving eCTD v 4.0 submission in 2016

Page 15: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

How do we prepare CDISC eSubmission?

15

• eCTD(Electronic Common Technical Document) v 3.2.2 for electronic submission

• Data Standard Strategy for CDISC

Page 16: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Electronic Common Technical Document

16

• Introduction of eCTD – an interface for industry to agency transfer of regulatory information

• Most recent version – v3.2.2• Define

– Module and its contents• Module 1 – Administrative information• Module 2 – eCTD summary document• Module 3 – Quality• Module 4 – Non-clinical Study Reports• Module 5 – Clinical Study Reports

– File formats (i.e., pdf, txt, xml, xpt and etc)

Page 17: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Electronic Common Technical Document

17

Page 18: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Data Standard Strategy

18

• Purpose – to reinforce CDER’s on-going commitment to the development, implementation and maintenance of data standard program on regulatory submissions.

• Objectives – Development of TA standards– Replacement of SAS XPORT files– Requirement of eSubmission

• Data Standard– CDER initiated 55 key TA domains– CDISC will be implemented and enhanced to support TA

standard development

Page 19: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

TA Data Standard Prioritization

19

Page 20: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Data Standard Strategy

20

Page 21: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

What do we prepare for CDISC eSubmission?

21

• CDISC components according to CDISC compliances

• Its electronic formats according to eCTD

Page 22: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

CDISC Clinical Trial Process

22

PRN (Protocol)

eCRF

ODM.xml, LAB SDTM TFLADaM

SAP

CDASH

CSR

Page 23: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

CDISC components in eSubmission

23

• Protocol• SAP• eCRF• SDTM• ADaM• SEND• CSR• Define.xml

Page 24: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Additional components in eSubmission

24

• ADaM SAS programs• Efficacy SAS programs (sometimes)

Page 25: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Formats of files according to eCTD

25

• Protocol – pdf (i.e., study001-protocol.pdf)• SAP – pdf (i.e., sutdy001-sap.pdf)• eCRF – pdf (i.e., sutdy001-blankecrf.pdf)• SDTM – xpt (i.e., dm.xpt, ae.xpt, ds.xpt, and etc)• ADaM – xpt (i.e., adsl.xpt, adae.xpt, adtteos.xpt, and etc)• SEND – xpt (i.e., dm.xpt, se.xpt, bw.xpt, and etc)• CSR – pdf (i.e., sutdy001-csr.pdf)• Define.xml – xml or pdf (i.e., define.xml/define.pdf)• ADaM SAS programs – txt (i.e., c-adsl-sas.txt)• Efficacy SAS programs – txt (i.e., t-14-01-001-ds-sas.txt )

Page 26: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Naming convention of files according to eCTD

26

• Lower case of letter from “a” to “z”• Number from “0” to “9”• “-” hypen• No special character ( #, %, $ and etc)• File name should be less than or equal to 64 characters

including the appropriate file extension• The length of entire path of the file should not exceed

230 characters. (m5/datasets/study001/sdtm/ae.xpt)

Page 27: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

pdf file guideline according to eCTD

27

• Version – 1.4 thru 1.7 are acceptable• Fonts

– Standard : Arial, Courier New, Times Roman– Sizes : range from 9 to 12 point ( Times New Roman 12-point

font is recommended for narrative text )

• Page– Print area : 8.5 inches by 11 inches– Margin : at least ¾ inch

Page 28: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

SAS xpt file guideline according to eCTD

28

• Length – Variable length is less than or equal to 8– Variable label is less than or equal to 40– Dataset length is less than or equal to 8– Dataset label is less than or equal to 40

• Dataset Size – less than 1 GB (LB1, LB2, and so on)• The length of character variables should be minimized

(i.e., if the maximum length of USUBJID is 20 character long, keep the length as 20, not 200)

Page 29: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Module 5 CSR Reports

29

CSR, SAP, Protocol

Page 30: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

CDISC Datasets eSubmission

30

ADaM datasets, Define.xml

ADaM SAS programs

SDTM datasets, Define.xml, SDTM annotated blank eCRF

Page 31: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

CDISC compliance

31

• SEND : config-send-3.0.xml • SDTM : config-sdtm-3.1.3.xml• ADaM : config-adam-1.0.xml• Define : config-define-2.0.xml• CDISC compliance by OpenCDISC

Page 32: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Conclusion

32

• Before : “should” in FDA documents means that something is suggested or recommended, but not required.

• After : “should” could mean required. • CDISC electronic submission will be

mandatory sometime in 2016 or 2017.

Page 33: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Contacts

33

• Email address : [email protected]• Linkedin :

– Profile : www.linkedin.com/in/kevinlee1995/

– Group : CDISC ADaM

• Tweet : @kevinlee_pharma or @cdisc_adam

Page 34: CDISC FDA Electronic Submission

www.cytel.com ©2013 Cytel Statistical Software & Services Pvt. Ltd.

Questions?

34