S.W.A.T(Stealth Watching All the Time)
Stealth Security & Home Theatre Systems, IncCrystal Lake, IL 60014-3506 Toll Free: (866) 424-3521 [email protected]
SECURITY SYTEMS CHICAGO CCTV INSTALLATIONS CHICAGO
HOME THEATER CHICAGO RESIDENTIAL CAMERA SYSTEMS CHICAGO
![Page 2: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/2.jpg)
Overview
Project Objectives and Purpose Approach Sub-systems Division of Labor Schedule Risks and Contingencies
![Page 3: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/3.jpg)
Project Statement
Home Security and Safety Detection of intruders Intruder prevention by alarms and lights Recording of home activity Generate reports (logs) Allow remote access
![Page 4: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/4.jpg)
Motivation for Implementing
Allow home owners to always know what is happening in their house Allow remote access to the system Fend off intruders
![Page 5: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/5.jpg)
System Diagram
![Page 6: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/6.jpg)
Control System
Communicates with each sensor Communicates with Visual Station Records data from sensors Responds to events (trigger alarm)
![Page 7: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/7.jpg)
Control System
Main control processor: ATMega128 RF link: ZigBee Wireless Internet: TBD Ethernet module Data Storage: SD cards Alarm Trigger: Standard IO Programming: C/C++ using Eclipse Visual Station: Connected via Serial
![Page 8: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/8.jpg)
Sensors
Infrared motion detection Magnetic proximity for doors/windows Glass integrity sensor Temperature sensor
![Page 9: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/9.jpg)
Sensors
Simple control processor: ATMega8RF link: ZigBee WirelessMagnetic sensors: HALL effect switchGlass Integrity: Glass Break DetectorTemperature: Analog or SerialInfrared Sensor: Self-Designed
![Page 10: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/10.jpg)
Visual Station
Contained within a laptop Continuously updating sensor values Graphically displays information Monitor and control system settings
![Page 11: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/11.jpg)
Alarms
Lights Noise (siren) Email
![Page 12: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/12.jpg)
Power Sources
All parts of the system will be powered by AC All digital components and chips will run at 3.3V
![Page 13: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/13.jpg)
Extras
Control the coffee pot or ovenLock doorsCamera nodesReal time graphs of each sensorOther Control Nodes (Turn on lights, open garage door)SMS notification
![Page 14: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/14.jpg)
Division of Labor
Programming: Paul and Pavel PCB Designs: Paul and Pavel Analog Circuitry: Jeff and Tyler Power Implementation: Jeff and Tyler Sensor Construction and Implementation: Jeff and Tyler Documentation and Testing: All
![Page 15: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/15.jpg)
Gantt Chart
![Page 16: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/16.jpg)
BudgetSTK 500 ProgrammerATMega128ATMega 8ZigBee ChipsTemperature SensorIR Sensor ComponentsMagnetic SensorBroken Glass SensorPCBPassivesPower CircuitryPower SuppliesAlarm LightsAlarm SirenBuffer Budget
Program MCU on Control System and Sensor Nodes3 Revs of the Control System MCU
3 Revs each sensor MCU3 Revs Wireless chips for all MCUs
3 Revs of Temp on all boards3 Revs of self built IR Sensor
3 Revs of Magnetic Sensor3 Revs of Broken Glass sensor
3 Revs of PCB (includes shipping/handling)3 Revs of Passive components3 Revs of Power for all Boards
Power the Control and Sensor BoardsSimple AlarmSound Alarm
Allow for unseen costs
![Page 17: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/17.jpg)
BudgetSTK 500 ProgrammerATMega128ATMega 8ZigBee ChipsTemperature SensorIR Sensor ComponentsMagnetic SensorBroken Glass SensorPCBPassivesPower CircuitryPower SuppliesAlarm LightsAlarm SirenBuffer Budget
TOTAL
$85$45$48$60$30$30$30$90
$120$60$90$35$15$10$77
$825
![Page 18: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/18.jpg)
Risks/Contingencies1. Wireless communication adds to
sensor interface complexity*Remove wireless link from sensors. Use simple wires.
2. Number of remote units increases complexity*Decrease number of remote units
![Page 19: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/19.jpg)
3. PC interface functionality of graphing and displaying data*Simplify the Visual Station graphing functionality
4. Remote access via web server*Simplify the web server or use the Visual Station instead
Risks/Contingencies
![Page 20: CCTV INSTALLATIONS CHICAGO](https://reader034.fdocuments.us/reader034/viewer/2022052602/559f5b261a28ab3f6b8b469d/html5/thumbnails/20.jpg)
Questions??
Stealth Watching All the Time