Product Specification

37258G

Genset Controlfor Multiple

Unit Operation

Peak shaving operation Stand-by operation AMF operation Cogeneration (CHP) Isolated & mains parallel operation Import/export control Soft loading features Open/closed transition Load sharing and load-dependent start/stop for up to 32 units Programmable operation sequences Multi-lingual capability CANopen / J1939 ECU Control Modbus RTU Protocol CE marked UL/cUL Listing LR & ABS Marine

DESCRIPTION

The easYgen-3000 Series are control units for genset management applications. The numerous inputs and outputs, along with a modular software structure, permit you to use the easYgen-3000 Series for a wide range of applications with only a single part number. This includes stand-by, AMF, peak shaving, import-export, coge-neration or distributed generation, among others. Also the easYgen-3000 Series is compatible for island, island parallel, mains parallel and multiple unit mains parallel operations. The easYgen-3000 Series is able to control up to 32 gensets connected in a network with automatic sequenc-ing.The easYgen-3000 Series is available in two variants, the easYgen-3100 for cabinet back panel installation, and the easYgen-3200 with graphical display and soft keys for front panel mounting.

FlexAppTM

– This feature provides the tools to easily configure the number of operated breakers: None, GCB, GCB and MCB.

LogicsManagerTM

– Woodward's LogicsManager software enables to change the operation sequences and adapt them to specific needs. The LogicsManager accomplishes this by monitoring a range of measuring val-ues and internal states, which are combined logically with Boolean operators and programmable timers. This enables to create and/or modify control and relay functions.

FlexInTM

– The analog inputs are configurable to operate with VDO, resistive, and/or 0 to 20 mA senders.

Flexible Outputs – Speed and voltage bias outputs are configurable to function with all speed governors and voltage regulators. The outputs can also be used as freely scalable outputs (e.g. for driving external meters).

FlexCANTM

– Advanced network interfaces ensure unsurpassed control performance – from engine control up to total plant operation. The easYgen-3000 Series is capable of working with all common industrial interfaces, including CAN, RS-232, and RS-485. The multiple communication protocols permit the easYgen-3000 Series to communicate with a vast majority of engine control units (ECUs), external I/O boards, PLCs, and modems. CANopen, J1939, Modbus RTU, and Modem protocols are supported.

DynamicsLCDTM

– The adaptive and interactive 5.7", 320x240 pixel graphical LC display with soft keys and a clear menu structure ensures intuitive user operation and navigation.

Features

Operation modes: Auto, Stop, Manual, and Load/No Load test modes via discrete input possible

Breaker control: Slip frequency / phase matching synchronization, open-close control, breaker monitoring

Load transfer features: open / closed transition, interchange, soft loading / soft unloading, mains parallel

Process and load-dependent start/stop logic for diesel and gas engines programmable for spinning or system reserve with fixed or dynamic priorities.

Real and reactive power load sharing with up to 32 units

Remote control via interface and discrete/analog inputs for adjusting speed, frequency, voltage, power, reactive power, and power factor set points

Complete integrated engine and generator protection as well as mains monitoring features

Freely configurable PID controllers for various control purposes, such as heating circuit control (CHP applica-tions), water level, fuel level, or pressure and/or other process values

Special Scania S6, MTU ADEC, Volvo EMS2 & EDC4, Deutz EMR2, MAN MFR/EDC7, SISU EEM, Cumminsand Woodward EGS02 ECU support (depending on Package)

Counters for operating hours / engine starts / maintenance / active energy / reactive energy

Configurable trip levels / delay timers / alarm classes for monitoring and protective functions

Clear text display and evaluation of up to 100 J1939 analog values

Discrete and analog I/O expansion board connectivity (Woodward IKD 1 or Phoenix Contact IL series)

Front panel and PC configurable (ToolKit software)

Multi-level password protection for access via HMI or interface

Multi-lingual capability !"#$%&'()*+,-."()/,+"0'()12."%&'()3'%"+&+()4.2."+&+()56.$%."()78,69#9+&+():9,;%&'()<9&&%."()78$%&'=

Event recorder (300 events, FIFO) with real time clock

Page 12: Catalogue

SPECIFICATIONS

78?+,)&922$@)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)BCDCE)FG0) H)68)EI)FG0=)5"6,%"&%0)08"&9-26%8")AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)-.JA)BK)L)M-N%+"6)6+-2+,.69,+) 82+,.6%8"=)AAAAAAAAAAAAAAAAAAAAAAA)OCI)68)KI)P3)D)OE)68)BQH)P/)M-N%+"6)6+-2+,.69,+) &68,.#+=)AAAAAAAAAAAAAAAAAAAAAAAA)ORI)68)HI)P3)D)OCC)68)BKS)P/)M-N%+"6)'9-%G%6@AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)TQ)U()"8"O08"G+"&%"#)Voltage)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA) ) D"=100 Vac [1]) <.6+G) F,.6+G=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)STDBCI)F.0)) V.JA)W.$9+) F-.J=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)HSDBQI)F.0)) ) <.6+G)&9,#+)W8$6A F&9,#+=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)CAQ);F)and 400 Vac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

^%#')5-2+G."0+)5"296`)<+&%&6."0+)2+,)2.6')AAAAAAA)aBb)IAETH)V#()aEb)CAI)V#)V.JA)28?+,)08"&9-26%8")2+,)2.6')AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)c)IABQ)L)Current (Isolated)) <.6+G) 5,.6+G=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)aBb)AADB)M)8,)aQb)AADQ)M)Z%"+.,)-+.&9,%"#),."#+)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)5#+")d)RAI[5,.6+G)) 5-.%"&D#,89"G)d)BAQ[5,.6+G)1+66%"#),."#+)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)B)68)RC(III)M)e9,G+")AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)c)IABQ)FM)<.6+G)&'8,6O6%-+)09,,+"6) B)&=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAaBb)QI[5,.6+G()aQb)BI[5,.6+G)Power)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA))1+66%"#),."#+)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)IAQ)68)TT(TTTAT);LD;W.,)Discrete inputs)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)%&8$.6+G)5"296),."#+)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)BCDCE)FG0) H)68)EI)FG0=)5"296),+&%&6."0+)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA).22,8JA)CI);X'-&))))

Relay outputs)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)%&8$.6+G)38"6.06)-.6+,%.$)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)M#3GX)Z8.G) *7=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)CAII)M.0fCQI)F.0)) CAII)MG0fCE)FG0)D)IARS)MG0fBCQ)FG0)D)IABH)MG0fCQI)FG0)7%$86)G96@) 7Y=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA))) BAII)MG0fCE)FG0)D)IACC)MG0fBCQ)FG0)D)IABI)MG0fCQI)FG0)Analog inputs (none isolated))AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA\,++$@)&0.$+.N$+):@2+)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)I)68)QII)X'-&)D)I)68)CI)-M)<+&8$96%8")AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)BB)e%6)Analog outputs (isolated))AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA\,++$@)&0.$+.N$+):@2+)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)g)BI)F)D)g)CI)-M)D)7LV)5"&9$.6%8")W8$6.#+) 08"6%"989&$@=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)BII)F.0)5"&9$.6%8")6+&6)W8$6.#+) B&=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)QII)F.0)<+&8$96%8")AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)BBDBC)e%6) G+2+"G%"#)8").".$8#)896296=)g)BI)F) &0.$+.N$+=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)%"6+,".$),+&%&6."0+)hB);X'-&)g)CI)-M) &0.$+.N$+=)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)-.J%-9-)$8.G)QII)X'-&)Housing) RCII=) ) /,8"6)2."+$)\$9&')-89"6%"#)AAAAAAAAAAAAAAAAAA)7$.&6%0)'89&%"#)Y%-+"&%8"&) ) LJ^JY)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)CHC)[)CBK)[)TT)--)/,8"6)096896) ) LJ^)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)CET)aiBABb)[)BHR)aiBAIb)--)38""+06%8")AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)&0,+?D2$9#)6+,-%".$&)CAQ)--j)/,8"6)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)%"&9$.6%"#)&9,\.0+)1+.$%"#) ) /,8"6)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)57SS) ?%6')&0,+?)\.&6+"%"#=)) ) /,8"6)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)57QE) ?%6')0$.-2)\.&6+"%"#=)) ) e.0;)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)57CI)L+%#'6)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA).22,8JA)B(HQI)#)Housing) RBII=) ) 1?%60')0.N%"+6)N.0;)-89"6%"#)AAAAA)1'++6)-+6.$)'89&%"#)Y%-+"&%8"&) ) LJ^JY)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)CQI)[)CCH)[)HE)--)38""+06%8")AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)&0,+?D2$9#)6+,-%".$&)CAQ)--j)7,86+06%8")&@&6+-)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)57)CI)L+%#'6)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA).22,8JA)C(BQI)#)Disturbance test) 3!=)AAAAAAAAAAAA)6+&6+G).008,G%"#)68).22$%0.N$+)!k)#9%G+$%"+&)Listings)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)lZ()0lZ) 0lZ)8"$@)\8,)+.&m#+"ORBII=)Marine)AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA)Z<) :@2+)M22,8W.$=()Me1) Y+&%#")M&&+&&-+"6=)

DIMENSIONS

Plastic housing for front panel mounting (3200) Metal housing for cabinet mounting (3100)

99 mm

282 mm

216 mm

247 mm

181 mm

87 mm

84 mm

227 mm

250 mm

Page 13: Catalogue

TERMINAL DIAGRAM

Page 14: Catalogue

)InternationalL88G?.,G))7X)e8J)BQBT)/8,6)38$$%"&)3X()l1M)HIQCCOBQBT)BIII)!.&6)Y,.;+)<8.G)/8,6)38$$%"&)3X)HIQCQ)7'n)iB) TKI=)EHCOQHBB)/.Jn)iB) TKI=)ETHORIQH))EuropeL88G?.,G)*-N^)^."G?+,;&6,.&&+)CT)KIQSQ)16966#.,6()*+,-."@)7'n)iET) I=)KBB)KHT)QEOI)/.Jn)iET) I=)KBB)KHT)QEOBII)+-.%$n)&6#6O%"\8f?88G?.,GA08-))Distributors & ServiceL88G?.,G)'.&).")%"6+,".6%8".$)"+6?8,;)8\)G%&6,%N968,&)."G)&+,W%0+)\.0%$%6%+&A)/8,)@89,)"+.,+&6),+2,+&+"6.6%W+()0.$$)6'+)/8,6)38$$%"&)2$."6)8,)&++)6'+)L8,$G?%G+)Y%,+068,@)8")89,)?+N&%6+A))))www.woodward.com/power)

19No+06)68)6+0'"%0.$)-8G%\%0.6%8"&A)

:'%&)G809-+"6)%&)G%&6,%N96+G)\8,)%"\8,-.6%8".$)29,28&+&)8"$@A)56)%&)"86)68)N+)08"&6,9+G).&)0,+.6%"#)8,)N+08-%"#)2.,6)8\)."@)L88G?.,G)*8W+,"8,)38-2."@)08"6,.069.$)8,)?.,,."6@)8N$%#.6%8")9"$+&&)+J2,+&&$@)&6.6+G)%").)?,%66+")&.$+&)08"6,.06A)

L+).22,+0%.6+)@89,)08--+"6&).N896)6'+)08"6+"6)8\)89,)29N$%0.O6%8"&A)7$+.&+)&+"G)08--+"6&)%"0$9G%"#)6'+)G809-+"6)"9-N+,)N+$8?)68)&6#6OG80f?88G?.,GA08-)

© Woodward

All Rights Reserved)RKCQH*)O)CIBIDIQD16966#.,6

FEATURES OVERVIEW

easYgen-3000 SeriesV8G+$) RBII) RCII)

7.0;.#+) 7B) ) ) 7C) ) ) 7B) ) ) 7C)Measuring*+"+,.68,)W8$6.#+) RO2'.&+DEO?%,+=) ) ) ) ) ) ) ) ) ) )

*+"+,.68,)09,,+"6) RJ)6,9+),A-A&A= ) ) ) ) ) ) ) ) ) )

V.%"&)W8$6.#+) RO2'.&+DEO?%,+=) ) ) ) ) ) ) ) ) ) )

V.%"&)8,)#,89"G)09,,+"6) BJ)6,9+),A-A&A=)pB) ) ) ) ) ) ) ) ) ) )

e9&N.,)W8$6.#+) BO2'.&+DCO?%,+=) ) ) ) ) ) ) ) ) ) )Controle,+.;+,)08"6,8$)$8#%0) 82+")."G)0$8&+G)6,."&%6%8"=) FlexAppTM) C) ) ) C) ) ) C) ) ) CM968-.6%0()V."9.$()1682()."G)6+&6)82+,.6%"#)-8G+&) ) ) ) ) ) ) ) ) )

1%"#$+)."G)-9$6%2$+O9"%6)82+,.6%8") ) ) ) ) ) ) ) ) )

V.%"&)2.,.$$+$)-9$6%2$+O9"%6)82+,.6%8") 92)68)RC)9"%6&=) ) ) )pC) ) ) ) ) ) )pC)

MV/) .968)-.%"&)\.%$9,+=)."G)&6."GON@)82+,.6%8" ) ) )

3,%6%0.$)-8G+)82+,.6%8") ) ) ) ) ) ) ) ) )

*3e)."G)V3e)&@"0',8"%_.6%8") &$%22%"#)D)2'.&+)-.60'%"#=) ) ) ) ) ) ) ) ) )

5"6+,0'."#+) %-28,6)D)+J28,6)08"6,8$=) ) ) ) ) ) ) ) ) )

Z8.GOG+2+"G+"6)&6.,6D&682) ) ) ) ) ) ) ) ) )

"D\()F()7()q()."G)7/),+-86+)08"6,8$)W%.).".$8#)%"296)8,)%"6+,\.0+) ) ) ) ) ) ) ) ) )

Z8.GDW.,)&'.,%"#)\8,)92)68)RC)#+"&+6&) ) ) ) ) ) ) ) ) )

/,++$@)08"\%#9,.N$+)75Y)08"6,8$$+,&) O) ) ) R) ) ) O) ) ) RHMI18\6);+@&) .GW."0+G)Z3)G%&2$.@=) DynamicsLCDTM) O) ) ) O) ) ) ) ) ) )

16.,6D&682)$8#%0)\8,)G%+&+$)D)#.&)+"#%"+&) ) ) ) ) ) ) ) ) )

389"6+,&)\8,)82+,.6%"#)'89,&)D)&6.,6&)D)-.%"6+"."0+)D).06%W+D,+.06%W+)+"+,#@ ) ) )

38"\%#9,.6%8")W%.)73)pR) ) ) ) ) ) ) ) ) )

!W+"6),+08,G+,)+"6,%+&)?%6'),+.$)6%-+)0$80;) N.66+,@)N.0;92=) RII) ) ) RII) ) ) RII) ) ) RII)Protection Mk15p

*+"+,.68,n)W8$6.#+)D)\,+]9+"0@) QT)D)CK)D)HBX)D)HBl) ) ) ) ) ) ) ) ) )

*+"+,.68,n)8W+,$8.G(),+W+,&+D,+G90+G)28?+,) RC)D)RC<)D)RC/) ) ) ) ) ) ) ) ) )

*+"+,.68,n)9"N.$."0+G)$8.G) ES) ) ) ) ) ) ) ) ) )

*+"+,.68,n)%"&6."6."+89&)8W+,09,,+"6) QI) ) ) ) ) ) ) ) ) )

*+"+,.68,n)6%-+O8W+,09,,+"6) 5!3)CQQ)08-2$%."6=) QB) ) ) ) ) ) ) ) ) )

*+"+,.68,n)#,89"G)\.9$6)pE) QI*) ) ) ) ) ) ) ) ) )

*+"+,.68,n)28?+,)\.068, QQ) ) ) ) ) ) ) ) ) )

*+"+,.68,n),86.6%8")\%+$G) ) ) ) ) ) ) ) ) ) )

!"#%"+n)8W+,&2++G)D)9"G+,&2++G) BC)D)BE) ) ) ) ) ) ) ) ) )

!"#%"+n)&2++G)D)\,+]9+"0@)-%&-.60') ) ) ) ) ) ) ) ) ) )

!"#%"+n)Yi).9J%$%.,@)+J0%6.6%8")\.%$9,+) ) ) ) ) ) ) ) ) ) )

V.%"&n)W8$6.#+)D)\,+]9+"0@) QT)D)CK)D)HBX)D)HBl) ) ) ) ) ) ) ) ) )

V.%"&n)2'.&+)&'%\6)D),86.6%8")\%+$G) KH)D) ) ) ) ) ) ) ) ) )I/Os12++G)%"296) -.#"+6%0)D)&?%60'%"#`)7%0;92=) ) ) ) ) ) ) ) ) )

Y%&0,+6+).$.,-)%"296&) 08"\%#9,.N$+=) BI) ) ) BI) ) ) BI) ) ) BI)

Y%&0,+6+)896296&) 08"\%#9,.N$+=) LogicsManagerTM) -.JA)BC) ) ) -.JA)BC) ) ) -.JA)BC) ) ) -.JA)BC)!J6+,".$)G%&0,+6+)%"296&)D)896296&)W%.)3Mk82+") -.J%-9-=) BS)D)BS) ) ) RC)D)RC) ) ) BS)D)BS) ) ) RC)D)RC)

M".$8#)%"296&)pQ) 08"\%#9,.N$+=)) FlexInTM) R) ) ) R) ) ) R) ) ) R

M".$8#)896296&) iDO)BIF()iDO)CI-M()7LV`)08"\%#9,.N$+=)) C) ) ) C) ) ) C) ) ) C!J6+,".$).".$8#)%"296&)D)896296&)W%.)3Mk82+") -.J%-9-=) O) ) ) BS)D)E ) ) O) ) ) BS)D)E)

Y%&2$.@)8\)4BTRT).".$8#)W.$9+&) "9-N+,)8\)17k&=) BS) ) ) O) ) ) BS) ) ) O)Y%&2$.@)."G)+W.$9.6%8")8\)4BTRT).".$8#)W.$9+&) &9228,6+G)17k&= O) ) ) BII) ) ) O) ) ) BII)

3Mk)N9&)08--9"%0.6%8")%"6+,\.0+&)pS) FlexCANTM) C) ) ) C) ) ) C) ) ) C

<1OCRCDEHQ)V8GN9&)<:l)1$.W+)%"6+,\.0+ &=) B)D)B) ) ) B)D)B) ) ) B)D)B) ) ) B)D)B)Listings/ApprovalslZ)Z%&6%"#) ) ) ) ) ) ) ) ) )

0lZ)Z%&6%"#) ) ) ) ) ) O) ) ) O)Z<)r)Me1)V.,%"+) ) ) ) ) ) ) ) ) )

3!)V.,;+G ) ) )Part NumbersBM)3:)%"296&)D)\,8"6)2."+$)-89"6%"#)?%6')G%&2$.@))pK) 7Dk)HEEIO) O) ) ) O) ) ) BTCC) ) ) BTCE)

QM)3:)%"296&)D)\,8"6)2."+$)-89"6%"#)?%6')G%&2$.@))pK) 7Dk)HEEIO) O) ) ) O) ) ) BTCR) ) ) BTCQ)BM)3:)%"296&)D)0.N%"+6)N.0;)-89"6%"#)?D8)G%&2$.@) 7Dk)HEEIO) BTRB) ) ) BTRR) ) ) O) ) ) O)

QM)3:)%"296&)D)0.N%"+6)N.0;)-89"6%"#)?D8)G%&2$.@) 7Dk)HEEIO) BTRI) ) ) BTRC) ) ) O) ) ) O)12.,+)08""+068,);%6) 7Dk)HTCRO) BRBE) ) ) BRBE) ) ) BRBE) ) ) BRBE)

) )

pB) -.%"&)8,)#,89"G)09,,+"6)&+$+06.N$+))pC) ,+\+,)68)6'+)M22$%0.6%8")V."9.$)RKEKB)\8,)

.22$%0.6%8"&)?%6')-8,+)6'.")H)2.,.$$+$)#+"&+6&)N+0.9&+)8\)N9&)$8.G)$%-%6&)

pR) W%.)&+,%.$)08""+06%8")."G):88$s%6)&8\6?.,+) %"0$9G+G=)pE) -+.&9,+G)#,89"G)09,,+"6)

pQ) &+$+06.N$+)G9,%"#)08"\%#9,.6%8")N+6?++")FYX) I)68)BHI)X'-()I)68)Q)N.,=()FYX) I)68)BHI)X'-()I)68)BI)N.,=()FYX) I)68)RHI)X'-()EI)68)BCIP3=()FYX) I)68)RHI)X'-()QI)68)BQIP3=()76BII()<+&%&6%W+)%"296) 8"+O)8,)6?8O28$+()C26A)$%"+.,)8,)T26A)9&+,)G+\%"+G)=()8,)CI)-M) IDE)68)CI -M()\,++$@)08"\%#9,.N$+=

pS) \,++$@)&+$+06.N$+)G9,%"#)08"\%#9,.6%8")N+6?++")3Mk82+")8,)4BTRT`),+]9+&6)%"\8,-.6%8"))pK) .)&0,+?)."G).)0$.-2);%6).,+)G+$%W+,+G)?%6')6'+)9"%6)\8,)\.&6+"%"#

For

more

info

rmation c

onta

ct:

Page 15: Catalogue

274 General Catalogue 2011-2012 SOCOMEC

SIRCOVER and

SIRCOVER BY-PASS

Manual Changeover Switches

Changeover switches with fully visualised breaking

from 125 to 3200 A

svr_

059_

a_1_

cat

Function

SIRCOVER products are manually

operated multipolar changeover switches.

They provide changeover, source inversion

or switching under load between two low

voltage power circuits, as well as their

safety isolation.

SIRCOVER BY-PASS are manually

operated changeover switches.

They are a combination of three interlocked

switches enabling the use with 3 + 6 pole

or 4 + 8 pole. They insulate by providing

simultaneous safety isolation top and

bottom and by passing loads of low

voltage circuits mainly during maintenance

operations.

Conformity

to standards

IEC 60947-3

IS 14947-3

EN 60947-3

VDE 0660-107

(1992)

NBN EN 60947-3

BS EN 60947-3

Approvals and

certifications (1)

Bureau Véritas

BBJ Poland

(Attestaion of

verification)

General characteristics

• 3 stable positions, (I, 0, II) or overlapping

contacts (I, I+II, II), and on load

changeover switching (AC-22 and AC-23).

• Fully visualized breaking.

• IP20 devices and accessories.

Available

on request

Devices 6 or 8 pole

Devices with over-

sized neutral ex.:

3 x 250 A + N 400 A.

Devices with

advanced neutral.

svr_

099_

b_

1_

cat

(1) Product reference on

request.

appli_

114_

a

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:274 Sec1:274 15/11/10 16:28:11

Page 16: Catalogue

275General Catalogue 2011-2012SOCOMEC

Manual Changeover Switches

SIRCOVER and SIRCOVER BY-PASS

svr_

136_

a_1_

x_ca

t

What you need to know

• SIRCOVER with 3 stable positions (I, O, II) are 3 or 4 pole devices from 125 A

to 3200 A. They are available enclosed in a steel or polyester enclosure from

125 to 1600 A.

• SIRCOVER with overlapping contacts (I-I+II-II) are 3 or 4 pole devices

available from 125 to 1800A. They are available enclosed in a steel enclosure

from 125 to 1600 A.

• SIRCOVER BY-PASS with 3 stable positions (I, O, II) are a combination of

three interlocked switches enabling the use with 3+6 poles or 4+8 poles from

125 to 1600 A. They are available in steel enclosure from 125 to 1600 A and

with overlapping contacts (I, I+II, II).

• SIRCOVER and SIRCOVER BY-PASS can be used with a direct or external

handle.

acce

s_226_

c_2_

cat

Top or bottom flatconnection

acce

s_231_

a_1_

cat

Top or bottom bridgingconnection

acce

s_229_

b_

2_

cat

Edgewise connectionTop or bottom

• A connection kit for copper bars allows the link between the 2 connection

terminals of one pole (fig 1 and 2) and the bridging of the upstream and

downstream link for ratings 2000, 2500 and 3200A (fig 3).

appli_

114_

a

Fig 1 Fig 2 Fig 3

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:275 Sec1:275 15/11/10 16:29:07

Page 17: Catalogue

General Catalogue 2011-2012 SOCOMEC276

SIRCOVER I-0-II

Rating

(A)

No. of

poles Switch body Direct handle

External

handle

Shaft for

external

handle Bridging bar*

Auxiliary

contacts

Terminal

shrouds

Terminals

protection

screen

125 A3 P 4100 3013(1)

Black

4199 5012(2)

Type S2

Black IP55

1421 2113

Black IP65

1423 2113(2)

200 mm

1400 1020

320 mm

1400 1032(2)

4109 0019

1st/2nd contact

NO/NC

4109 0021(4)

3 P

2694 3014(5)(6)

4 P

2694 4014(5)(6)

3 P

1509 3012(7)

4 P

1509 4012(7)

4 P 4100 4013(1)

160 A3 P 4100 3016(1)

4 P 4100 4016(1)

200 A3 P 4100 3019

4 P 4100 4019

250 A

3 P 4100 3025(1)

4109 0025 3 P

2694 3021(5)(6)

4 P

2694 4021(5)(6)

3 P

1509 3025(7)

4 P

1509 4025(7)

4 P 4100 4025(1)

400 A

3 P 4100 3039(1)

4109 0039

4 P 4100 4039(1)

500 A

3 P 4100 3050(1)

4109 0050 3 P

2694 3051(5)(6)

4 P

2694 4051(5)(6)

3 P

1509 3063(7)

4 P

1509 4063(7)

4 P 4100 4050(1)

630 A

3 P 4100 3063(1)

4109 0063

4 P 4100 4063(1)

800 A

3 P 4100 3080(1)

Black

2799 7052(2)

S4 type

Black IP65

1443 3113(2)

200 mm

1401 1520

320 mm

1401 1532(2)

4109 0080 3 P

1509 3080(7)

4 P

1509 4080(7)

4 P 4100 4080(1)

1 250 A

3 P 4100 3120(1)

4109 0120

4 P 4100 4120(1)

1 600 A3 P 4100 3160(1)

4109 0160

3 P

1509 3160(7)

4 P

1509 4160(7)

4 P 4100 4160(1)

1 800 A3 P 4100 3180

4 P 4100 4180

2 000 A3 P 4100 3200

Black

2799 7012(2)

Black IP65

2799 7146(2)

320 mm

2799 3018(2)(3)

1st contact

NO/NC

included

2nd contact

NO/NC

4409 0022(4)

included

4 P 4100 4200

2 500 A3 P 4100 3250

4 P 4100 4250

3 200 A3 P 4100 3320

4 P 4100 4320

svr_

051_

a_1_

cat

SIRCOVER and SIRCOVER BY-PASS - References

* 1 piece required per pole.

(1) Available enclosed (see pages 498 and 500 "Enclosed changeover switches").

(2) Standard.

(3) See page 281 "Copper bars connection kits".

(4) 2 pieces: one for position I and one for position II.

(5) To shroud front switch top and bottom 2 references required.

(6) To fully shroud front, rear, top and bottom 4 references required.

(7) 2 pieces: one for top side and another for bottom side.

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:276 Sec1:276 15/11/10 16:29:43

Page 18: Catalogue

General Catalogue 2011-2012SOCOMEC

Manual Changeover Switches

SIRCOVER and SIRCOVER BY-PASS

277

SIRCOVER and SIRCOVER BY-PASS

SIRCOVER I - I+II - II

Rating (A)

No. of

poles Switch body Direct handle

External

handle

Shaft for

external

handle Bridging bar*

Auxiliary

contacts

Terminal

shrouds

Terminal

screens

125 A

3 P 4190 3013(1)

Black

4199 5012(2)

S2 type

Black IP65

1423 2114(2)

200 mm

1400 1020

320 mm

1400 1032(2)

4109 0019

1st/2nd contact

NO/NC

4109 0021(3)

3 P

2694 3014(4)(5)

4 P

2694 4014(4)(5)

3 P

1509 3012(6)

4 P

1509 4012(6)

4 P 4190 4013(1)

160 A

3 P 4190 3016(1)

4 P 4190 4016(1)

200 A

3 P 4190 3019

4 P 4190 4019

250 A

3 P 4190 3025(1)

4109 00253 P

2694 3021(4)(5)

4 P

2694 4021(4)(5)

3 P

1509 3025(6)

4 P

1509 4025(6)

4 P 4190 4025(1)

400 A

3 P 4190 3039(1)

4109 0039

4 P 4190 4039(1)

500 A

3 P 4190 3050(1)

4109 0050 3 P

2694 3051(4)(5)

4 P

2694 4051(4)(5)

3 P

1509 3063(6)

4 P

1509 4063(6)

4 P 4190 4050(1)

630 A

3 P 4190 3063(1)

4109 0063

4 P 4190 4063(1)

800 A

3 P 4190 3080(1)

Black

2799 7052(2)

S4 type

Black IP65

1443 3114(2)

200 mm

1401 1520

320 mm

1401 1532(2)

4109 00803 P

1509 3080(6)

4 P

1509 4080(6)

4 P 4190 4080(1)

1 250 A

3 P 4190 3120(1)

4109 0120

4 P 4190 4120(1)

1 600 A

3 P 4190 3160(1)

4109 0160

3 P

1509 3160(6)

4 P

1509 4160(6)

4 P 4190 4160(1)

1 800 A

3 P 4190 3180

4 P 4190 4180

svr_

051_

a_1_

cat

* 1 piece required per pole.

(1) Available enclosed (see pages 498 and 500 "Enclosed changeover switches").

(2) Standard.

(3) 2 pieces: one for position I and one for position II.

(4) To fully shroud front, rear, top and bottom 4 references required.

(5) To shroud front switch top and bottom 2 references required.

(6) 2 pieces: one for top side and another for bottom side.

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:277 Sec1:277 15/11/10 16:29:46

Page 19: Catalogue

General Catalogue 2011-2012 SOCOMEC278

SIRCOVER BY-PASS

Rating (A)

No. of

poles

Switch body

I-0-II Direct handle

External

handle

Shaft for

external

handle Bridging bar

Auxiliary

contacts

Terminal

shrouds

Terminal

screens

125 A

3 + 6 P 4100 7013(1)

Black

4199 5012(2)

S2 type

Black IP55

1421 2113(2)

Black IP65

1423 2113

200 mm

1400 1020

320 mm

1400 1032(2)

4109 0019

1st/2nd

contact

NO/NC

4109 0021(3)

3 P

2694 3014(4)(5)

4 P

2694 4014(4)(5)

3 P

1509 3012(6)

4 P

1509 4012(6)

4 + 8 P 4100 9013(1)

160 A

3 + 6 P 4100 7016(1)

4 + 8 P 4100 9016(1)

200 A

3 + 6 P 4100 7019

4 + 8 P 4100 9019

250 A

3 + 6 P 4100 7025(1)

Black

2799 7052(2)

S3 type

Black IP65

1433 3113(2)

200 mm

1401 1520

320 mm

1401 1532(2)

4109 0025 3 P

2694 3021(4)(5)

4 P

2694 4021(4)(5)

3 P

1509 3025(6)

4 P

1509 4025(6)

4 + 8 P 4100 9025(1)

400 A

3 + 6 P 4100 7039(1)

4109 0039

4 + 8 P 4100 9039(1)

500 A

3 + 6 P 4100 7050(1)

4109 0050 3 P

2694 3051(4)(5)

4 P

2694 4051(4)(5)

3 P

1509 3063(6)

4 P

1509 4063(6)

4 + 8 P 4100 9050(1)

630 A

3 + 6 P 4100 7063(1)

4109 0063

4 + 8 P 4100 9063(1)

800 A

3 + 6 P 4100 7080(1)

Black

2799 7012(2)

Black IP65

4199 7146(2)

200 mm

2799 3015

450 mm

2799 3019(2)

4109 00803 P

1509 3080(6)

4 P

1509 4080(6)

4 + 8 P 4100 9080(1)

1 250 A

3 + 6 P 4100 7120(1)

4109 0120

4 + 8 P 4100 9120(1)

1 600 A

3 + 6 P 4100 7160

4109 0160

3 P

1509 3160(6)

4 + 8 P 4100 91604 P

1509 4160(6)

svr_

059_

a_4_

cat

SIRCOVER and SIRCOVER BY-PASS - References (continued)

* For By-Pass 2 pieces are required per pole.

(1) Available enclosed (see pages 498 and 500 "Enclosed changeover switches").

(2) Standard.

(3) 2 pieces: one for position I and one for position II.

(4) To shroud front switch top and bottom 3 references required.

(5) To fully shroud front, rear, top and bottom 6 references required.

(6) 2 pieces: one for top side and another for bottom side.

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:278 Sec1:278 15/11/10 16:29:49

Page 20: Catalogue

General Catalogue 2011-2012SOCOMEC

Manual Changeover Switches

SIRCOVER and SIRCOVER BY-PASS

279

SIRCOVER and SIRCOVER BY-PASS

Direct handle

acce

s_129_

b_

1_

cat

acce

s_153_

a_2_

cat

SIRCOVER

Rating (A) Handle color Handle type Reference

125 … 630 Black Single lever 4199 5012

800 … 1800 Black Single lever 2799 7052

2000 … 3200 Black Double lever 2799 7012

SIRCOVER BY-PASS

Rating (A) Handle color Handle type Reference

125 … 200 Black Single lever 4199 5012

250 … 630 Black Single lever 2799 7052

800 … 1600 Black Double lever 2799 7012

External operation handle

acce

s_150_

a_1_

cat

S2 type handle

acce

s_151_

a_1_

cat

S3 type handle

acce

s_152_

a_2_

cat

S4 type handle

Use

The door interlocked external operation handle includes one padlockable handle, one

escutcheon and must be utilised with a shaft extension.

SIRCOVER

Rating (A)

Switching

type

External

IP(1) Handle Reference

125 … 630 I - 0 - II IP55 S2 type 1421 2113

125 … 630 I - 0 - II IP65 S2 type 1423 2113

125 … 630 I - I+II - II IP65 S2 type 1423 2114

800 … 1800 I - 0 - II IP65 S4 type 1443 3113(2)

800 … 1800 I - I+II - II IP65 S4 type 1443 3114(2)

2000 … 3200 I - 0 - II IP65 2799 7146(2)

(1) IP: Degree of protection according to standard IEC 60529.

(2) Double lever handle.

SIRCOVER BY-PASS

Rating (A)

Switching

type

External

IP(1) Handle Reference

125 … 200 I - 0 - II IP55 S2 type 1421 2113

125 … 200 I - 0 - II IP65 S2 type 1423 2113

250 ... 630 I - 0 - II IP65 S3 type 1433 3113

800 … 1600 I - 0 - II IP65 4199 7146

(1) IP: Degree of protection according to standard IEC 60529.

Alternative S-type handle cover colours

acce

s_198_

a_2_

cat

Use

For single lever handles S1, S2, S3 type and for double lever handle S4 type.

Other colours: Consult us.

Color

To be ordered

in multiples of Handle Reference

Light grey 50 S2, S3 type 1401 0001

Dark grey 50 S2, S3 type 1401 0011

Light grey 50 S4 type 1401 0031

Dark grey 50 S4 type 1401 0041

Accessories

S type handle adapter

acce

s_187_

a_1_

cat

Use

Enables S type handles to be fitted in place

of existing older style Socomec handles.

Adapter can also be utilised as a spacer to

increase the distance between the panel

door and the handle lever.

Dimensions

Adds 12 mm to the depth.

Color

To be ordered

in multiples of External IP(1) Reference

Black 10 IP65 1493 0000

(1) IP: Degree of protection according to standard IEC 60529.

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:279 Sec1:279 15/11/10 16:29:53

Page 21: Catalogue

General Catalogue 2011-2012 SOCOMEC280

Shaft for external handle

acce

s_143_

b_

1_

cat

acce

s_144_

b_

1_

cat

X

acce

s_202_

a_1_

cat

Use

Standard lengths:

- 200 mm,

- 320 mm,

- 450 mm.

Other lengths: Consult us.

SIRCOVER

Rating (A)

Shaft length

(mm)

Dimension X

(mm) Reference

125 … 400 200 mm 210 … 310 1400 1020

125 … 400 320 mm 210 … 430 1400 1032

500 … 630 200 mm 280 … 390 1400 1020

500 … 630 320 mm 280 … 510 1400 1032

800 … 1800 200 mm 425 … 577 1401 1520

800 … 1800 320 mm 425 … 697 1401 1532

2000 … 3200 320 mm 653 … 923 2799 3018(1)

SIRCOVER BY-PASS

Rating (A)

Shaft length

(mm)

Dimension X

(mm) Reference

125 … 200 200 mm 320 … 450 1400 1020

125 … 200 320 mm 320 … 570 1400 1032

250 … 400 200 mm 298 … 420 1401 1520

250 … 400 320 mm 298 … 540 1401 1532

500 … 630 200 mm 417 … 539 1401 1520

500 … 630 320 mm 417 … 659 1401 1532

800 … 1600 200 mm 550 … 680 2799 3015(1)

800 … 1600 450 mm 550 … 800 2799 3019(1)

Bridging bars

acce

s_205_

a_2_

cat

SIRCOVER

acce

s_041_

a_1_

cat

acce

s_208_

a_2_

cat

SIRCOVER BY-PASS

svr_

068_

a_1_

x_ca

t

svr_

124_

a_1_

cat

Use

Creation of a common link, on the top or

bottom side of the switch, in order to feed

load with either power supply I or/and II. For

SIRCOVER BY-PASS, two sets of bridging

bars are needed as the switch is composed

of three basic switch frames.

Position I: 6 or 8 poles

Position II: 3 or 4 poles

Rating (A) Section (mm) Reference

125 … 200 20 x 2.5 4109 0019

250 25 x 2.5 4109 0025

400 32 x 5 4109 0039

500 32 x 5 4109 0050

630 50 x 5 4109 0063

800 50 x 6 4109 0080

1250 60 x 8 4109 0120

1600 ... 1800 90 x 10 4109 0160

SIRCOVER and SIRCOVER BY-PASS - References (continued)

Shaft guide for external operation

acce

s_260_

a_2_

cat

Use

To guide the shaft extension into the external handle.

This accessory enables handle to engage extension shaft with a misalignment of up to 15 mm.

Required for a shaft lenght over 320 mm.

Description Reference

Shaft guide 1429 0000

(1) Extension shaft.

(1) Extension shaft.

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:280 Sec1:280 15/11/10 16:30:07

Page 22: Catalogue

General Catalogue 2011-2012SOCOMEC

Manual Changeover Switches

SIRCOVER and SIRCOVER BY-PASS

281

SIRCOVER and SIRCOVER BY-PASS

Auxiliary contacts

acce

s_065_

a_1_

cat

svr_

058_

a_1_

cat

Use

Pre breaking and positions I and II

signalling: 1 or 2 NO/NC auxiliary contacts

in each position.

Low level auxiliary contacts: Consult us.

Connection to the control circuit

By 6.35 mm fast-on terminal.

Electrical characteristics

30 000 operations.

NO/NC changeover contact

Rating (A) Contact(s) Reference

125 … 1800 1st/2nd 4109 0021

2000 … 3200 1st included

2000 … 3200 2nd 4409 0022

Characteristics

Nominal

current (A)

Operating current Ie (A)

Rating (A)

A - 250

-13VAC

400 VAC

AC-13

24 VDC

DC-13

48 VDC

DC-13

125 … 3200 16 12 8 14 6

a

acce

s_226_

b_

1_

x_ca

t

Fig.1

acce

s_228_

b_

1_

x_ca

t

Fig. 2

A

B

Fig. 3

252

74

37

74

37 60

129

155

acce

s_232_

a_1_

cat

30303030 132 30303030 22

210

acce

s_233_

a_1_

cat

30303030 148

225

acce

s_234_

a_1_

cat

Copper bars connection kits for 2000 to 3200 A SIRCOVER

Use

Enables:

- To allow connection between the two

power terminals from a same pole for

2000 to 3200A ratings (Fig. 1 and Fig 2).

- Top or bottom bridging connection (Fig. 3).

For 3200 A rating, the connection pieces

(part A) are delivered bridged from factory.

Bolt sets must be ordered separately.

Technical notice for these specific

accessories is downloadable from

www.socomec.com

Rating (A) Piece

Quantity to order

per pole(1) Reference

2 000 … 2 500 Connection - part A 2 2619 1200

2 000 … 2 500 Bolt set - part B 2 2699 1200

3 200 Connection - part A included

3 200 Bolt set - part B 2 2699 1200

(1) Example for 3 pole device equipped upstream only: order 3 times the indicated quantities.

Rating (A) Piece

Quantity to order

per pole(1) Reference

2 000 … 2 500 Connection - part A 2 2619 1200

2 000 … 2 500 T piece - part C 2 2629 1200(2)

2 000 … 2 500 Right angle - part D 2 2639 1200(2)

3 200 Connection - part A included

3 200 T piece - part C 2 2629 1200(2)

3 200 Right angle - part D 2 2639 1200(2)

(1) Example for 3 pole device equipped upstream only: order 3 times the indicated quantities.

(2) Bolt set is provided with the accessories.

Rating (A) Piece

Quantity to order

per pole(1) Reference

2 000 … 2 500 Connection - part A 2 2619 1200

2 000 … 2 500 Bolt set - part B 2 2699 1200

2 000 … 2 500 Bar - piece E 1 4109 0250(2)

2 000 … 2 500 T piece - part C 1 2629 1200(2)

3 200 Connection - part A included

3 200 Bolt set - part B 2 2699 1200

3 200 Bar - piece E 1 4109 0320(2)

3 200 T piece - part C 1 2629 1200(2)

(1) Example for 3 pole device equipped upstream only: order 3 times the indicated quantities.

(2) Bolt set is provided with the accessories.

Top or bottom flat connection - Fig. 1

Top or bottom edgewise connection - Fig. 2

Top or bottom bridging connection -Fig. 3

acce

s_230_

b_

1_

x_ca

t

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:281 Sec1:281 15/11/10 16:30:17

Page 23: Catalogue

General Catalogue 2011-2012 SOCOMEC282

Terminal shrouds

acce

s_206_

a_2_

cat

Use

Protection against direct contact with

terminals or connecting parts.

Advantage

Perforations allowing remote

thermographic inspection without removal.

Rating (A)

No. of

poles Position Reference

125 … 200 3 P top / bottom / front (I) / rear (II) 2694 3014(1)(2)

125 … 200 4 P top / bottom / front (I) / rear (II) 2694 4014(1)(2)

250 … 400 3 P top / bottom / front (I) / rear (II) 2694 3021(1)(2)

250 … 400 4 P top / bottom / front (I) / rear (II) 2694 4021(1)(2)

500 … 630 3 P top / bottom / front (I) / rear (II) 2694 3051(1)(2)

500 … 630 4 P top / bottom / front (I) / rear (II) 2694 4051(1)(2)

(1) To shroud front switch top and bottom 4 references required for a SIRCOVER and 6

references for a SIRCOVER BY-PASS.

(2) To shroud front switch top and bottom 2 references required for a SIRCOVER and a

SIRCOVER BY-PASS.

Terminal screens

acce

s_207_

a_2_

cat

Use

Top or bottom protection against direct contact with terminals or connection parts.

Rating (A) No. of poles Position Reference

125 ... 200 3 P top / bottom 1509 3012

125 ... 200 4 P top / bottom 1509 4012

250 ... 400 3 P top / bottom 1509 3025

250 ... 400 4 P top / bottom 1509 4025

500 ... 630 3 P top / bottom 1509 3063

500 ... 630 4 P top / bottom 1509 4063

800 ... 1 250 3 P top / bottom 1509 3080

800 ... 1 250 4 P top / bottom 1509 4080

1 600 ... 1 800 3 P top / bottom 1509 3160

1 600 ... 1 800 4 P top / bottom 1509 4160

2 000 ... 3 200 3 / 4 P top / bottom included

SIRCOVER and SIRCOVER BY-PASS - References (continued)

Inter phase barriers

acce

s_036_

a_1_

cat

Use

Safety isolating separation between the terminals, essential for use at 690 VAC

or in a polluted or dusty atmosphere.

The terminal shrouds also provide phase separation from 125 to 630 A.

Rating (A) No. of poles Reference

125 … 200 3 P 2998 0033 (1)

125 … 200 4 P 2998 0034(1)

250 ... 400 3 P 2998 0023(1)

250 ... 400 4 P 2998 0024(1)

500 ... 630 3 P 2998 0013(1)

500 ... 630 4 P 2998 0014(1)

800 ... 3200 3 / 4 P included

(1) Use 2 sets per side.

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:282 Sec1:282 15/11/10 16:30:47

Page 24: Catalogue

General Catalogue 2011-2012SOCOMEC

Manual Changeover Switches

SIRCOVER and SIRCOVER BY-PASS

283

SIRCOVER and SIRCOVER BY-PASS

Other specific accessories

bd_

03_

04_

01

• Customised protection screens (for specific dimensions or high ambiant temperatures).

• Inter phase barrier.

• Connection accessories.

• Low level auxiliary contacts.

Handle key interlocking accessories

acce

s_061_

a_1_

x_ca

t

Fig. 1

acce

s_001_

a_1_

x_ca

t

Fig. 2

acce

s_132_

a_1_

x_ca

t

Fig. 3

acce

s_158_

a_1_

x_ca

t

Fig. 4

Use

• using padlock (not supplied), this device is factory mounted in the direct or

external operation handle and allows using up to 3 padlocks (Fig.1).

• Locking:

- using lock (not supplied)

- using undervoltage coil.

The interlocking positions are either determined as standard or configured by the

user, removing pre-formed tabs.

Padlocking and locking can be combined.

Lockable in position I, 0 or II

Rating (A)

SIRCOVER

Rating (A)

SIRCOVER

BY-PASS Operation Figure Reference

125 … 630 125 … 200 external 1 1423 2813

Locking using RONIS EL11AP lock in position 0 (not included)

Rating (A)

SIRCOVER

Rating (A)

SIRCOVER

BY-PASS Operation Figure Reference

125 … 630 125 … 200 direct 2 4109 1006(1)

250 ... 630 direct 3 consult us

800 … 1800 800 … 1600 direct 3 4109 1004(2)

2000 … 3200 direct 3 4109 2007

125 … 1800 125 … 630 external 4 1499 7701

2000 … 3200 800 … 1600 external 4 2799 7002

(1) Specific handle included.

(2) This locking facility can be configured by the user in the 3 positions.

Locking using RONIS EL11AP lock in position I, 0, II (not included)

Rating (A)

SIRCOVER

Rating (A)

SIRCOVER

BY-PASS Operation Figure Reference

125 … 630 125 … 200 direct 2 4109 1002(1)

250 … 630 direct 3 consult us

800 … 1800 800 … 1600 direct 3 4109 1004(2)

2000 … 3200 direct 3 4109 2007

125 … 1800 125 … 630 external 4 1499 7701

800 … 1600 external 4 2799 7002

(1) Specific handle included.

(2) This locking facility can be configured by the user in the 3 positions.

Locking using 230 VAC undervoltage coil in position 0 (factory fitted)

Rating (A)

SIRCOVER

Rating (A)

SIRCOVER

BY-PASS Operation Figure Reference

800 … 3200 800 … 1600 direct 3 consult us

Locking using CASTELL type K lock (not included)

Rating (A)

SIRCOVER

Rating (A)

SIRCOVER

BY-PASS Operation Figure Reference

125 … 1800 125 … 630 external 4 1499 7702

2000 … 3200 800 … 1600 external 4 2799 7003

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:283 Sec1:283 15/11/10 16:30:52

Page 25: Catalogue

General Catalogue 2011-2012 SOCOMEC284

SIRCOVER and SIRCOVER BY-PASS - Characteristics according to IEC 60947-3

Thermal current Ith (40°C) 125 A 160 A 200 A 250 A 400 A 500 A

Rated insulation voltage Ui (V) 800 800 800 800 800 1000

Rated impulse withstand voltage Uimp (kV) 8 8 8 8 8 12

Rated operational currents Ie (A)

Rated voltage Load duty category A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1)

400 VAC AC-21 A / AC-21 B 125/125 160/160 200/200 250/250 400/400 500/500

400 VAC AC-22 A / AC-22 B 125/125 160/160 200/200 250/250 400/400 500/500

400 VAC AC-23 A / AC-23 B 125/125 160/160 160/160 250/250 250/250 500/500

690 VAC(2) AC-20 A / AC-20 B 125/125 160/160 200/200 250/250 400/400 500/500

690 VAC(2) AC-21 A / AC-21 B 125/125 160/160 160/160 200/250 200/250 400/400

690 VAC(2) AC-22 A / AC-22 B 125/125 125/125 125/125 125/160 125/160 250/315

690 VAC(2) AC-23 A / AC-23 B 63/80 63/80 63/80 100/125 100/125 160/200

220 VDC DC-20 A / DC-20 B 125/125 160/160 200/200 250/250 400/400 500/500

220 VDC DC-21 A / DC-21 B 125/125 160/160 160/160 250/250 250/250 500/500

220 VDC DC-22 A / DC-22 B 125/125 160/160 160/160 250/250 250/250 400/500

220 VDC DC-23 A / DC-23 B 125/125 125/125 125/125 200/200 200/200 400/400

440 VDC DC-20 A / DC-20 B 125/125 160/160 200/200 250/250 400/400 500/500

440 VDC DC-21 A / DC-21 B 125(3)/125(3) 125(3)/125(3) 125(3)/125(3) 200(3)/200(3) 200(3)/200(3) 400(3)/400(3)

440 VDC DC-22 A / DC-22 B 125(3)/125(3) 125(3)/125(3) 125(3)/125(3) 200(3)/200(3) 200(3)/200(3) 315(3)/400(3)

440 VDC DC-23 A / DC-23 B 125(4)/125(4) 125(4)/125(4) 125(4)/125(4) 200(4)/200(4) 200(4)/200(4) 400(4)/400(4)

Operational power in AC-23 (kW)

At 400 VAC without pre-break in AC(1)(5) 63/63 80/80 80/80 132/132 132/132 280/280

At 690 VAC without pre-break in AC(1)(5) 55/75 55/75 55/75 90/110 90/110 150/185

Reactive power (kvar)

At 400 VAC (5) 55 75 90 115 185 230

Fuse protected short-circuit withstand (kA rms prospective)

Prospective short-circuit (kA rms)(6) 100 100 50 50 18 100

Associated fuse rating (A) (6) 125 160 200 250 400 500

Overload capacity

Rated short-time withstand current 0.3 s. ICW (kA eff.) 15 15 15 17 17 25

Rated peak withstand current (kA peak) (6) 20 20 20 30 30 45

Connection

Minimum Cu cable section (mm2) 35 50 50 95 185 240

Minimum Cu busbar section (mm2)

Maximum Cu cable section (mm2) 50 95 95 150 240 240

Maximum Cu busbar width (mm) 25 25 25 32 32 40

Tightening torque min (Nm) 9 9 9 20 20 20

Mechanical characteristics

Durability (number of operating cycles)(7) 10 000 10 000 10 000 10 000 10 000 5 000

Weight of 3 P switch (kg) 1.5 1.6 1.8 2 3 3.5

Weight of 4 P switch (kg) 1.6 1.7 1.9 2.1 3.5 4

125 to 500 A

(1) Category with index A = frequent operation - Category with index B = infrequent operation.

(2) With terminal shrouds or phase barrier.

(3) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-".

(4) 4-pole device with 2 pole in series by polarity.

(5) The power value is given for information only, the current values vary from one manufacturer to another.

(6) For a rated operational voltage Ue = 400 VAC.

(7) Increased endurances: please consult us.

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:284 Sec1:284 15/11/10 16:30:53

Page 26: Catalogue

General Catalogue 2011-2012SOCOMEC

Manual Changeover Switches

SIRCOVER and SIRCOVER BY-PASS

285

SIRCOVER and SIRCOVER BY-PASS

Thermal current Ith (40°C) 630 A 800 A 1250 A 1600 A 1800 A 2000 A 2500 A 3200 A

Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000

Rated impulse withstand voltage Uimp (kV) 12 12 12 12 12 12 12 12

Rated operational currents Ie (A)

Rated voltage Load duty category A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1)

400 VAC AC-21 A / AC-21 B 630/630 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3200/3200

400 VAC AC-22 A / AC-22 B 630/630 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2000/2500 2500/3200

400 VAC AC-23 A / AC-23 B 500/500 800/800 1250/1250 1250/1250 1250/1250 1600/1600 1600/1600 1600/1600

690 VAC(2) AC-20 A / AC-20 B 630/630 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3200/3200

690 VAC(2) AC-21 A / AC-21 B 500/500 800/800 800/800 1000/1000 1000/1000 2000/2000 2000/2500 2000/2500

690 VAC(2) AC-22 A / AC-22 B 315/315 800/800 800/800 1000/1000 1000/1000 1000/1000 1000/1000 1000/1000

690 VAC(2) AC-23 A / AC-23 B 160/200 200/250 200/250 500/500 500/500 800/800 800/800 800/800

220 VDC DC-20 A / DC-20 B 630/630 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3200/3200

220 VDC DC-21 A / DC-21 B 630/630 800/800 1250/1250 1250/1250 1250/1250 2000/2000 2000/2500 2000/2500

220 VDC DC-22 A / DC-22 B 500/500 800/800 1250/1250 1250/1250 1250/1250 1250/1600 1250/1600 1250/1600

220 VDC DC-23 A / DC-23 B 500/500 800/800 1250/1250 1250/1250 1250/1250 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3)

440 VDC DC-20 A / DC-20 B 630/630 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3200/3200

440 VDC DC-21 A / DC-21 B 500(3)/500(3) 800(3)/800(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 2000/2000 2000/2000 2000/2000

440 VDC DC-22 A / DC-22 B 500(3)/500(3) 800(3)/800(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3)

440 VDC DC-23 A / DC-23 B 500(4)/500(4) 800(3)/800(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1000(3)/1000(3) 1000(3)/ 1000(3) 1000(3) /1000(3)

Operational power in AC-23 (kW)

At 400 VAC without pre-break in AC(1)(5) 280/280 450/450 710/710 710/710 710/710 710/710 710/710 710/710

At 690 VAC without pre-break in AC(1)(5) 150/185 185/220 185/220 475/475 475/475 750/750 750/750 750/750

Reactive power (kvar)

At 400 VAC (5) 290 365 575

Fuse protected short-circuit withstand (kA rms prospective)

Prospective short-circuit (kA rms)(6) 70 50 100 100 100 100 100

Associated fuse rating (A) (6) 630 800 1250 2 x 800 2 x 800 2 x 1000 2 x 1250

Overload capacity

Rated short-time withstand current 0.3 s. ICW (kA eff.) 25 50 65 100 100 100 100 110

Rated peak withstand current (kA peak) (6) 45 55 80 110 110 110 110 120

Connection

Minimum Cu cable section (mm2) 2 x 150 2 x 185

Minimum Cu busbar section (mm2) 2 x 30 x 5 2 x 40 x 5 2 X 60 X 5 2 x 80 x 5 2 x 80 x 5 3 x 100 x 5 4 x 100 x 5 4 x 100 x 5

Maximum Cu cable section (mm2) 2 x 300 2 x 300 4 X 185 6 x 185 6 x 185

Maximum Cu busbar width (mm) 50 63 63 100 100 125 125 125

Tightening torque min (Nm) 20 20 40 40 40 40 40

Mechanical characteristics

Durability (number of operating cycles)(7) 5 000 3 000 3 000 4 000 4 000 3 000 3 000 3 000

Weight of 3 P switch (kg) 3.5 17.5 22.5 34 34 50 50 50

Weight of 4 P switch (kg) 4 21 27.5 42 42 60 60 60

(1) Category with index A = frequent operation - Category with index B = infrequent operation.

(2) With terminal shrouds or phase barrier.

(3) 3-pole device with 3 pole in series for the "+" and 1 pole for the "-".

(4) 4-pole device with 2 pole in series per polarity.

(5) The power value is given for information only, the current values vary from one manufacturer to another.

(6) For a rated operational voltage Ue = 400 VAC.

(7) Increased endurances: please consult us.

630 to 3200 A

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:285 Sec1:285 15/11/10 16:30:54

Page 27: Catalogue

General Catalogue 2011-2012 SOCOMEC286

Direct front operation

Rating (A)

Overall dimensions Switch mounting

A

3p.

A

4p.

M

3p.

M

4p.

2000 … 3200 478 598 347 467

==

425

653

103

436.5

425

38

0

33

0

33

0

M 51.5

53.5120120120

A

25

8

25

0

46

1

svr_

128_

c_1_

x_ca

t

SIRCOVER 2000 to 3200 A

SIRCOVER and SIRCOVER BY-PASS - Dimensions

Direct front operation External front operation

Rating

(A)

Overall dimensions

Terminal

shrouds Switch body Switch mounting Connection

A

3p.

A

4p. C E min AC H HA

J

3p.

J

4p.

M

3p.

M

4p. N T U V W

X

3p.

X

4p. Y Z Z1 AA BA AC

125 221 251 218 208 ... 436 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3,5 28 124 135 115 10

160 221 251 218 208 ... 436 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3,5 28 124 135 115 10

200 221 251 218 208 ... 436 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3,5 28 124 135 115 10

250 262 312 218 208 ... 436 280 148 25 223 273 196 246 116 50 25 30 11 61 61 3,5 30 124 160 130 15

400 262 312 218 208 ... 436 280 148 25 223 273 196 246 116 50 35 35 11 61 61 3,5 30 124 170 140 15

500 319 379 295 285 ... 513 401 225 25 272 332 246 306 176 65 32 37 13 70.5 65.5 5 43 180 235 205 15

630 319 379 295 285 ... 513 400 225 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 260 220 20

800 386 466 375 425 ... 577 459 298 29 306.5 386.5 255 336 250 80 50 60.5 15 48 48 7 66.5 253.5 321 26.5

1250 386 466 375 425 ... 577 459 298 29 306.5 386.5 255 336 250 80 60 65 16x11 48 48 7 66.5 255.5 330 29.5

1600 478 598 375 425 ... 577 461 298 29 306.5 388.5 347 467 250 120 90 43.5 12.5x5 54 54 8 66.5 255.5 288 15

1800 478 598 375 425 ... 577 461 298 29 388.5 518.5 347 467 250 120 90 43.5 12.5x5 54 54 8 66.5 255.5 288 15

II I

35

0

12

5

L1

N

V

60 45

B0

III

A

8.5

C

H

18

10

A Z1

Z

Y Y

1

2

H HA

E min.X T T

J

T

M

U W

AC

AA

BA

CA

CA

svr_

072_

i_1_

x_ca

t

A. S2 type handle for external operation: 125 to 630 A

B. S4 type handle for external operation: 800 to 1800 A

1. Terminal shrouds

2. Direct handle operation:

- 125 to 630 A: L1 = 140 mm,

- 800 to 1800 A: L1 = 210 mm.

SIRCOVER 125 to1800 A

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:286 Sec1:286 15/11/10 16:30:55

Page 28: Catalogue

General Catalogue 2011-2012SOCOMEC

Manual Changeover Switches

SIRCOVER and SIRCOVER BY-PASS

287

SIRCOVER and SIRCOVER BY-PASS

33 8.58.5

50

33

10

ø 9

ø 15

svr_

077_

a_1_

x_ca

t

SIRCOVER and SIRCOVER BY-PASS 800 A

Connection terminals

15

5 5

12

.5

25 25

30304545

90

ø12.5

svr_

098_

a_1_

x_ca

t

SIRCOVER 1600 to 3200 A

SIRCOVER BY-PASS 1600 A

SIRCOVER and SIRCOVER BY-PASS 1250 A

16 x 11

60

28.5 15.7515.75

28

.51

5

svr_

078_

b_

1_

x_ca

t

Direct front operation

External front operation

Rating (A)

Overall dimensions

Terminal

shrouds Switch body Switch mounting Connection

A

3+6p.

A

4+8p. C

E

min AC H HA

J

3+6 p.

J

4+8 p.

M

3+6 p.

M

4+8 p. N T U V W

X

3+6p.

X

4+8p. Y Z Z1 Z2 AA BA AC

125 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8,5 56 50 3.5 28 124 219 135 115 10

160 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8,5 56 50 3.5 28 124 219 135 115 10

200 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8,5 56 50 3.5 28 124 219 135 115 10

250 262 312 313 298 280 243 25 223 273 196 246 116 50 25 30 11 61 61 3.5 30 124 219 160 130 10

400 262 312 313 298 280 243 25 223 273 196 246 116 50 35 35 11 61 61 3.5 30 124 219 170 140 15

500 319 379 432 417 401 362 25 272 332 246 306 176 65 32 37 13 70.5 65.5 5 43 180 317 235 205 15

630 319 379 432 417 400 362 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 317 260 220 20

800 386 466 560 550 459 479 29 306.5 386.5 255 335 250 80 50 60.5 15 48 48 7 66.5 253.5 439.5 321 26.5

1250 386 466 560 550 459 479 29 306.5 386.5 255 335 250 80 60 65 16x11 48 48 7 66.5 253.5 439.5 320 29.25

1600 478 598 560 550 461 479 29 388.5 518.5 347 467 250 120 90 43.5 12.5x5 54 54 8 66.5 253.5 439.5 288 15

210

12

5

33

0=

=

BA C

61

45HA

E min.

H

J

X T

UW

A

10

8.5

Z

Z1

Z2

Y Y Y

1

2

18C

H

L1

CA

CA

BA

AA

AC

V

II

I III

I

0 N

M

T T

103

svr_

070_

i_1_

x_ca

t

A. S2 type handle for external operation:

125 to 200 A

B. S3 type handle for external operation:

250 to 630 A

C. External double lever handle: 800 to 1600 A

1. Terminal shrouds

2. Direct handle operation:

- 125 to 200 A: L1 = 140 mm,

- 250 to 630 A: L1 = 210 mm,

- 800 to 1600 A: L1 = Ø 330 mm.

SIRCOVER BY-PASS 125 to 1600 A

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:287 Sec1:287 15/11/10 16:30:56

Page 29: Catalogue

General Catalogue 2011-2012 SOCOMEC288

Dimensions for external handles

4 Ø 7

2 Ø 6.5

20 20

Ø 37

Ø 37

79

22

45°

1414

S2 type

Direction of operationHandle type

Front operation

Door drilling

With lockRONIS EL11AP

With lockCASTELL K

Ø78

45

125

4 Ø 7

1414

20 20

(1)Ø D

90° 90°

I II

0

o

I+II

4 Ø 5.5

Ø 26

4 Ø 7

20 20

Ø 37

73.5

2624

45° 3.5

28

1414

28.5

svr_

138_

a_1_

gb_

cat

(1) Ø31 to Ø37: rear screw mounting

Ø37: front clip mounting.

SIRCOVER 125 to 630 A

0

or

I+II

I II

60

350

Ø78

(2)4 Ø 7

1414

20 20

(1)Ø D

90° 90°

4 Ø 7

2 Ø 6.5

20 20

Ø 37

Ø 37

79

22

45°

1414

4 Ø 5.5

Ø 26

4 Ø 7

20 20

Ø 37

73.5

2624

45° 3.5

28

1414

28.5

S4 type

Direction of operationHandle type

Front operation

Door drilling

With lockRONIS EL11AP

With lockCASTELL K

svr_

139_

a_1_

gb_

cat

(1) Ø31 to Ø37: rear screw mounting

Ø37: front clip mounting.

(2) Ø6 to Ø7: fast fixing.

SIRCOVER 800 to1800 A

C type

0

II

I

90°

90°

50

Ø 31

300

50

4 Ø 6.5

96

50

50 2

5

28

4 x Ø 6.5 3 x Ø 6.5Ø 31

Direction of operationHandle type

Front operation

Door drilling

With lockCASTELL K

svr_

140_

a_1_

gb_

cat

SIRCOVER 2000 to 3200 A

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:288 Sec1:288 15/11/10 16:30:58

Page 30: Catalogue

General Catalogue 2011-2012SOCOMEC

Manual Changeover Switches

SIRCOVER and SIRCOVER BY-PASS

289

SIRCOVER and SIRCOVER BY-PASS

Ø78

45

125

4 Ø 7

1414

20 20

(1)Ø D

90° 90°

I II

0

4 Ø 7

2 Ø 6.5

20 20

Ø 37

Ø 37

79

22

45°

1414

4 Ø 5.5

Ø 26

4 Ø 7

20 20

Ø 37

73.5

2624

45° 3.5

28

1414

28.5

S2 type

Direction of operationHandle type

Front operation

Door drilling

With lockRONIS EL11AP

With lockCASTELL K

svr_

141_

a_1_

gb_

cat

(1) Ø31 to Ø37: rear screw mounting Ø37: front clip mounting.

SIRCOVER BY-PASS 125 to 200 A

4 Ø 7

1414

20 20

(1)Ø D

Ø78

61

21

0

90° 90°

I II

0

4 Ø 7

2 Ø 6.5

20 20

Ø 37

Ø 37

79

22

45°

1414

4 Ø 5.5

Ø 26

4 Ø 7

20 20

Ø 37

73.5

2624

45° 3.5

28

1414

28.5

S3 type

Direction of operationHandle type

Front operation

Door drilling

With lockRONIS EL11AP

With lockCASTELL K

svr_

142_

a_1_

gb_

cat

(1) Ø31 to Ø37: rear screw mounting Ø37: front clip mounting.

SIRCOVER BY-PASS 250 to 630 A

Ø 31

50

30

0

50

4 Ø 6.590°

90°

II

I

0

96

50

50 2

5

28

4 x Ø 6.5 3 x Ø 6.5Ø 31

C type

Direction of operationHandle type

Front operation

Door drilling

With lockCASTELL K

svr_

143_

a_1_

gb_

cat

SIRCOVER BY-PASS 800 to 1600 A

C0112A_GB_SIRCOVER_BP_b_bat.inddSec1:289 Sec1:289 15/11/10 16:30:59

Page 31: Catalogue

DE

IFA

/S

Application The protective differential current relay type RMC-131D forms part of a complete DEIF series of relays for protection and control of generators, and is primarily designed for marine applications. Also available are short circuit relays (RMC-111D), combined short circuit and overcurrent relays (RMC-122D) and double overcurrent relays (RMC-132D).

The RMC-131D is type approved by major classification societies and is applied for protection of e.g. generators in 3-phase networks against leakage currents.

Measuring principleThe relay compares the differential current of each of the 3 phases, providing an RMS measurement at sinusoidal currents.

In order to obtain a short response time on a fault condition, the measurement is based on peak values.

The differential currents are obtained by connecting the external current transformers for each winding in parallel with inverse polarity.

The measurement is not stabilized, implying that the relay contact is activated for disconnection of the supervised unit when the differential current of the individual phases exceeds its set point, irrespective of the amperage of these.

The 3 differential currents are measured by the relay and the highest of these is selected. If this exceeds the set point, the output is activated.

The set point value is set on the front of the relay by means of a potentiometer. If exceeded, a fault signal is generated, and the associated yellow LED is lit.

Timer functionWhen the set point has been exceeded, the associated timer starts and will run as long as the fault condition prevails.

The delay (3 ranges) does not depend on the exceeding of the set point. If the fault disappears, the timer is reset. When the timer expires, the contact is activated and the associated red LED is lit.

Relay outputThe RMC-131D is provided with one relay coil with 2 maximum contacts. The relay can be configured either to normally energised or normally de-energised. The contacts may be set to open or to close on activation (same function on both contacts).

Normally energised contactRecommended for marine installation for warning and alarm purposes.

In case of an auxiliary supply drop-out, the contact is immediately activated.

Normally de-energised contactRecommended for marine installations for regulating and control purposes.

An auxiliary supply failure will not result in an unwanted activation of the contact.

Latch circuitThe contact can then be locked in its warning position, even if the input currents return to normal (add ”L” to contact type in order specifications, if this is required).

The latch circuit is reset by disconnecting the auxiliary supply.

HysteresisIn order to avoid ”chatter” on the relay contacts the contact functions are provided with a hysteresis, i.e. a difference of 2% of full scale between energising and de-energising of the relay.

Power-up/power-down circuitsThe RMC-131D is provided with a 200 ms power-up circuit, ensuring the correct function of the relay on connection of the auxiliary voltage.

Note: Normally energised contacts are not activated

(contact does not open/close) until 200 ms after connection of the auxiliary voltage.

Likewise, the RMC-131D is provided with a 200 ms power-down circuit, ensuring supervision and maintenance of any set point exceedings for 200 ms after disconnection of the auxiliary voltage.

ANSI code 87 Differential current relaysType RMC-131D uni-line

4921240104G

•••• Measurement of 3 phase currents

•••• Non-stabilised measurement

•••• LED indication of fault condition

•••• Timer controlled tripping

•••• LED indication for activated relay

•••• Extra change-over relay contact for signalling

•••• 35 mm DIN rail or base mountingRMC-131D

Page 32: Catalogue

Technical specificationsMeas. range (In): 0.3-0.4-0.5-0.6-0.8-1.0-1.3-1.5-2.0-

2.5-3.0-4.0-5.0A AC

Adjusted range: 75...100% of In (e.g. 0.4, 0.45, etc.). (lowest meas. range: 0.3A)

Frequency range: 40...45...65...70Hz.

Differential current: 0.04...0.4 x In.

Max. input current: 4 x In, continuously,

20 x In for 10 s (max. 75A) 80 x In for 1 s (max. 300A).

Load: Max. 0.3VA per phase.

Output: 1 maximum contact.

Contact type: Contact B, contact C: Normally energised (“NE”), or normally de-energised (“ND”) with or without latch circuit (“L”)

Relay contact: 2 sets of change-over switches

Contact ratings: 250V-8A-2000VA (AC) 24V-8A-200W (DC) (200 x 10

3 change-overs at resistive

load)

Contact voltage: Max. 250V (AC). Max. 150V (DC).

Hysteresis: 2% of full scale (F.S.).

Response time: <50 ms.

Temperature: -25...70°C (operating).

Temperature drift: Set points:

max. 0.2% of full scale per 10°C.

Galvanic separation: Between inputs, outputs and aux.

voltage: 3250V - 50Hz - 1 min.

Supply voltage (Un): 57.7-63.5-100-110-127-200-220-230-

240-380-400-415-440-450-660-690V AC ±20% (max. 3.5VA)

24-48-110-220V DC -25/+30% (max. 2W).

Climate: HSE, to DIN 40040.

EMC: To EN 50081-1/2, EN 50082-1/2,

SS4361503 (PL4) and IEC 255-3.

Connections: Max. 4 mm² (single-stranded).

Max. 2.5 mm² (multi-stranded).

Materials: All plastic parts are self-extinguishing

to UL94 (V1).

Protection: Case: IP40. Terminals: IP20,

to IEC 529 and EN 60529.

Type approval: The uni-line components are

approved by the major classification societies. For current approvals see www.deif.com or contact DEIF A/S.

Settings and indicationSetting of LED/relay

Differential current set point:

(4…40%) of ln

”l’>” yellow LED is lit when the set point has been exceeded, but the contact not yet activated.

Time delay: (0…T1) in seconds 0…1/0…5/0…10 s

Contact is activated and red LED lit after the timer has expired.

The relay is furthermore equipped with a green LED marked ”POWER” for indication of power ON. Once the relay has been mounted and adjusted, the transparent front cover may be sealed, preventing unwanted change of the setting.

Connections/dimensions (in mm)

Shown contact positions: auxiliary voltage not connected

Weight: approx. 0.650 kg

Order specifications Type – Measuring current (ln) – Relay – Time delay (T1) – Supply voltage

Example: RMC-131D – 5A AC – NEL - 5 s – 440V AC

Type RMC-131D

Note: Current transformers with the same characteristics must be used on both sides. The cable burden must be the same on both sides. Current transformers must be used for RMC-131D only.

Due to our continuous development we reserve the right to supply equipment which may vary from the described.

DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark

Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: [email protected], URL: www.deif.com

Page 33: Catalogue
Page 34: Catalogue
Page 35: Catalogue
Page 36: Catalogue
Page 37: Catalogue
Page 38: Catalogue
Page 39: Catalogue

Ove

rcur

rent

Rel

ay

Technical DataRATINGS

Rated current ( In ) : 5 A

Rated frequency : 50 Hz

Burden : < 0.3 VA at In

Thermal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK203A-240A : 198 ~ 265 V AC

Model MK203A-110A : 94 ~ 127V AC

Supply frequency : 50 Hz

VA rating : 3 VA typical

SETTING RANGES

Low-set ( I > ) : 2.0 A to 6.0 A

: 40% to 120%

Time multiplier ( TM ) : 0.05 to 1.0

High-set ( I >> ) : I > to 10 x I > or disable

High-set delay time (t >>) : Instantaneous

TIME CURRENT CHARACTERISTIC CURVE

- Normal Inverse

CONTACTS

Trip contact (R1) : Manual reset type

Contact Arrangement : Change-over

Contact rating : 5 A, 250 V AC ( cos = 1 )

Contact material : Silver alloy

Expected electrical life : 100,000 operations at

rated current

Expected mechanical life: 5 x 106 operations

INDICATORS

Auxiliary supply : Green indicator

Pick-up : Red indicator

Trip : Red indicator

PERFORMANCE

Adjustable accuracy : Less than ±5%.

Repeatability : Less than 0.5% of full scale.

MECHANICAL

Mounting : Panel mounting

Front panel : Standard DIN

96 mm x 96 mm

Approximate weight : 0.7 kg

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚C

Humidity : 56 days at 93% RH and

40˚C non-condensing

Features

• Microprocessor based numerical relay

• Current measurement based on

fundamental frequency

• Low-set inverse de"nite minimum time

( IDMT ) relay

• High-set instantaneous relay

• Separate low-set and high-set trip

indicators

• Option to disable high-set relay

• Front panel access to test function

• Complies with IEC 60255-26 standard

MK203A

MK203A

Page 40: Catalogue

Ove

rcur

rent

Rel

ay

Aux

62 3 4 5

L

R1

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO NC

16

1

MK 203A

TYPICAL APPLICATION DIAGRAM

62 3 4 5

L

R1

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO

AUX AUXMK 203A

NC

16

1 62 3 4 5

L N

9 10 11 12 13 14

7

15

8

COMNO

MK 202A

NC

16

1

R1

COMBINED IDMT OVERCURRENT & EARTH FAULT RELAYS

96 mm

Front

96

mm

110 mm

100 mm

Side

91.0 0.5 mm

91

.0

0.5

mm

Panel Cutout

CASE DIMENSIONS

MK203A

Ordering Information

MK203A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC

MK203A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTION

NORMAL INVERSE

Page 41: Catalogue
Page 42: Catalogue
Page 43: Catalogue
Page 44: Catalogue
Page 45: Catalogue
Page 46: Catalogue
Page 47: Catalogue
Page 48: Catalogue
Page 49: Catalogue
Page 50: Catalogue
Page 51: Catalogue
Page 52: Catalogue
Page 53: Catalogue
Page 54: Catalogue
Page 55: Catalogue
Page 56: Catalogue
Page 57: Catalogue

Basic loading data (for Single anchor) in concrete:HLC, HLC-H, HLC-EC/EO, HLC-L, HLC-SK, HLC-T

Issue 2008Page 1

- steel galvanized to min. 5 micronsHLC-H,SK,L,T:

Characteristic resistance, Rk [kN]: fc,cube 25 N/mm2

HLC

2

5.2

7.9

1.4 1.8 2.8 4.0

7.9Shear VRec 5.73.5kN 1.5 2.8

Recommended load, Lrec [kN]: fc,cube 25 N/mm2

208 10Anchor Size

2.0 2.5 7.4

3.9 4.9 8.0

4.0

12

7.2

5.5

Tensile NRec kN

10.0

14.4 20.0

kN 2.1

3.8

kN 1.2

kN

Anchor Size 6.5

Tensile NRd

HLC Sleeve Anchor

- for concrete, solid brick, sand limestone

- force controlled expansion

- setting mark for choosing the right anchor le

Features:

12 16 20

- fire test report

8

Material:

10

7.0 8.8

Anchor Size

kN

6.5

HLC, -EO,EC:

3.5 13.2

20.0

4.5

8 10

Design resistance, Rd [kN]: fc,cube 25 N/mm2

20

2.1Tensile NRk

Shear VRk

- Bolt steel grade 8.8

- min. tensile strength 500MPa

- steel galvanized to min. 5 microns

16

16

12

Shear VRd

6.5

11.1 11.1

0.8

Page 58: Catalogue

Basic loading data (for Single anchor) in solid brick1,2,3

: HLC, HLC-H, HLC-EC/EO, HLC-L, HLC-SK, HLC-T

2) For brick walls where anchor position in brick can not be determined, 100% anchor testing is recommended.

Setting Details

Anchor position in concrete Anchor position in Solid masonry brick

distance to free edge for solid masonry units is 30 cm

Edge distance and anchor spacing given in setting details distance to horizontal and vertical mortar joint 5.5 cm

Issue 2008

6.5 12

12 16

1.0 1.2

HLC Sleeve Anchor

Page 2

Anchor Size

0.4 0.5

3) The HLC anchor was installed and tested in center of solid bricks as shown. The HLC anchor was not tested in the mortar joint between solid

bricks or in hollow bricks, however a load reduction is expected.

1) The technical data for the HLC sleeve anchors are reference loads for MZ 12 and KS 12. Due to the large variation of natural stone solid bricks,

on site anchor testing is recommended to validate technical data.

108

0.8

1.4 1.6

1.0

0.80.6

1.6 1.60.65

10

0.6

16

KS 12-2,0-2DF Recommended load, Lrec [kN]: fbrick 29 N/mm2

6.5 8

0.3 0.5kN

Shear VRec

MZ 12-2,0-2DF Recommended load, Lrec [kN]: fbrick 19 N/mm2

0.8

1.2

Tensile NRec kN

Shear VRec kN

kN 0.45

Anchor Size

Tensile NRec 0.7

5.5 cm5.5 cm

5.5 cm

5.5 cm

5.5 cm

24 cm

11 cm

11 cm

Anchor position in Brick

5.5 cm5.5 cm

5.5 cm

5.5 cm

5.5 cm

24 cm

11 cm

11 cm

Anchor position in Brick

scrccr

Page 59: Catalogue

HLC, HLC-H, HLC-EC/EO, HLC-L

6.5

x25/5

6.5

x40/2

0

6.5

x60/4

0

8x40/1

0

8x55/2

5

8x70/4

0

8x85/5

5

10x40/5

10x50/1

5

10x60/2

5

10x80/4

5

10x100/6

5

12x55/1

5

12x75/3

5

12x100/6

0

16x60/1

0

16x100/5

0

16x140/9

0

20x80/2

5

20x115/6

0

20x150/9

5

30 45 65 46 61 76 91 48 58 68 88 108 65 85 110 72 112 152 95 130 165

25 40 60 40 55 70 85 40 50 60 80 100 55 75 100 60 100 140 80 115 150

5 20 40 10 25 40 55 5 15 25 45 65 15 35 60 10 50 90 25 60 95

HLC-SKHLC, HLC-H, HLC-EC/EO, HLC-L

10

Page 3

5040

mm

30

HLC Sleeve Anchor

85

Issue 2008

Critical Edge Distance

Critical Spacing

2.5

80

scr

30 50

60 100

mm

mm 120 130 160 160

60 65 80ccr

l Total Anchor length

8

Max. Fixing length1

Tinst

lc Anchor length under washer mm

16

mm

mmhef Min. Anchorage depth

M6 M8M5

12

M16

d0 Drill bit diameter 8 10 16 20

M10 M12

6.5 (1/4")

9 11

65 75

13

15

17

hmin

Min. Thickness of the base

material2)

Tightening torque concrete 5

60

mm

mm

8

Tinst Tightening torque masonry

df Clearance hole mm

Sw Width across nut flats

HLC

HLC-

H

mm

4 13 20

13

10070

Nm

80

7

80

24

31

25 40

17

100

25 -

19

21

41

Nm

mm

413326

120

50

mmMin. Borehole depth

Anchor Size

Setting details

Thread diameterd

1)When setting long anchors to achieve intermediate fixing length be advised of the base material thickness, use caution when drilling boreholes to

the maximum depth, to avoid back side blow out.

tfix

1)For anchrors loaded in shear towards the edge the critiacl edge distance must be doubeled

Max. Borehole depth

h1

mm h1,max = h (actual base material thickness) - 10mm -d0

Sw

d

Page 60: Catalogue

HLC-SK

6.5

x45/2

0

6.5

x65/4

0

6.5

x85/6

0

8x60/2

5

8x75/4

0

8x90/5

5

10x45/5

10x85/4

5

10x105/6

5

10x130/9

5

45 65 85 60 75 90 45 85 105 130

20 40 60 25 40 55 5 45 65 95

Installation equipment

Setting operations

100

80

60

120

134

8

T 40

130

M8

10

50

,max = h (actual base material thickness) - 10mm -

26 31

8

M6

40

1)When setting long anchors to achieve intermediate fixing length be advised of the base material thickness, use caution when drilling boreholes to

the maximum depth, to avoid back side blow out.

12x55/1

5

M10

12

65

33

80

35

40

20

scr Critical Spacing mm 60

6550

60hminMin. Thickness of the base

materialmm

ccr Critical Edge Distance mm 30

- PZ 3 T 40Setting Driver T 30

10070

Tinst Tightening torque masonry Nm 2.5

25Tinst Tightening torque concrete Nm 5

tfix Max. Fixing length1 mm

l Total Anchor length mm

Max. Borehole depth mm

hef Min. Anchorage depth mm 16

h1

Min. Borehole depth mm 30

d0 Drill bit diameter mm 6.5 (1/4")

Thread diameter M5

Anchor Size

Setting details

Issue 2008Page 4

HLC Sleeve Anchor

Rotary hammer ( TE2, TE6, TE6A, TE7, TE 7A, TE16, TE 16-C, TE 16-M, TE 35 ), a drill ( see table above), a

hammer and a torque wrench

d