1
As of today, all you need is a single device for both climate and energy control in the home. The new Clima thermostats and time-thermostats combine cutting-edge technology with the utmost practicality. Whether wall- or flush-mounted, battery or mains powered, designed for stand alone operation or integrated into a home automation system, they help create the perfect climate and optimise energy consumption of the entire building. With the simplicity of a touch.
Clima&Energy: advanced solutions for temperature control and energy supervision.
4
Complete supervision, easy to read and intuitive installation.The new thermostats and time-thermostats come with intuitive controls and easy-to-read touch screens. They allow for simple and comprehensive temperature control, whether you are at home or away, and display consumption levels to encourage energy saving. Furthermore, in the time-thermostat versions, the boiler on and off settings can be made on a daily or weekly basis.
SURFACE MOUNTING
The thermostats and time-thermostats have a large high-sensitivity touch screen display, with white backlighting in the GSM version, allowing the device to be managed with just a touch.
Touch screen display.
The lightweight, slim silhouette, reflex finish and sophisticated design enable the devices to integrate perfectly into any context.
Slim profile. Hotkeys.
Preset buttons allow rapid access to a number of functions. With just a touch you can set the temperature to a stand–by level if you are going out or lower it by a couple of degrees.
5
All products are equipped with an advanced algorithm that keeps the temperature as stable as possible, avoiding excessive fluctuations and promoting energy saving. It is also possible to monitor the total number of hours of operation of the boiler.
PID algorithm.
The new By-clima App allows you to keep everything under control at all times.The GSM surface mounting thermostats can be managed directly using this intuitive application. It is a particularly useful tool for second homes, allowing you to control the climate with complete peace of mind even when you are away.
The large display is able to show energy production and total consumption of the building or of a single load and emits an acoustic alert on exceeding a threshold for an anti-blackout function. So you can always keep an eye on energy efficiency.
Maintaining the ideal temperature in each room is simple and intuitive. The internal sensor calibration function allows for more precise measurements. Simply access the setting function and you're done!The touch screen display allows you to turn thoughts into action even more rapidly.
Energy functionClimate function
Display of consumption values.
The ideal temperature, at all times.
New By-clima App.
An intuitive indicator that uses a graduated scale to display consumption values and a leaf symbol to indicate that the comfort temperature has been exceeded, thus encouraging greater energy awareness.
Ecometer function.
GSM
Configurable inputs for remote control, energy saving or summer/winter switching and for temperature sensors used to display, adjust or limit consumptions.
Multifunction configurable inputs.
6
Outstanding scope for customisation and perfect aesthetic coordination.In the flush mounting version, the climate and energy control functions combine to offer the maximum choice. The thermostats and time-thermostats are equipped with a high-sensitivity LED RGB backlit touch screen display to ensure perfect aesthetic coordination with the finishes of the cover plates or with the temperature values set in the Ecometer mode.
This intuitive indicator uses a graduated scale and dynamic display colour to indicate consumption values. It warns when the comfort temperature is exceeded to encourage greater energy awareness.
Ecometer function.Hotkeys.
Preset buttons allow rapid access to a number of functions. With just a touch you can set the temperature to a stand–by level if you are going out or lower it by a couple of degrees for nighttime reduction.
Configurable multifunction inputs.Input channel for remote control, energy saving activation or summer/winter switching plus a configurable temperature sensor input.
FLUSH MOUNTING
7
Aesthetic quality comes as standard.
The displays of the flush mounting thermostats and time-thermostats all feature LED backlighting with a choice of RGB colours for full customisation. The colour of the characters thus coordinates with the colour of the chosen cover plate.
All possible colour tones.
Maintaining the ideal temperature in each room is simple and intuitive. The internal sensor calibration function allows for more precise measurements. Simply access the setting function and you're done! The touch screen display allows you to turn thoughts into action even more rapidly.
Climate function
The ideal temperature, at all times.
The large display is able to show energy production and total consumption of the building or of a single load and emits an audible alert on exceeding a threshold for an anti-blackout function.So you can always keep an eye on energy efficiency.
Energy function
Display of consumption values.
All products are equipped with an advanced algorithm that keeps the temperature as stable as possible, avoiding excessive fluctuations and promoting energy saving. The total number of boiler operating hours can also be monitored.
PID algorithm.
The By-clima App has an intuitive interface that allows you to rapidly program thermostats and time-thermostats by sending an audio signal directly from the app to the product. This simplifies and speeds up programming in all rooms and enables you to set your favourite functions.
By-clima App: programming without limits.
7
The new flush mounting products coordinate perfectly with the series Eikon, Arké and Plana. A single code with limitless scope for combination with the chosen cover plates to adapt perfectly to the styles and materials chosen for the building.
8
HOME AUTOMATION
Integration with By-me and Well-contact Plus automation systems: advanced functions for climate and energy management.
BUILDING AUTOMATION
developed to standard
8
9
The new flush mounting products integrate perfectly with both the By-me home automation system
and the KNX Well-contact Plus building automation system, offering the very best in terms of ease
of installation, performance and functionality as well as clear and complete information. Whatever
the field of application - whether residential building, hospitality facilities, shopping centres, offices or
public buildings - climate and energy are controlled to perfection to ensure the maximum benefits.
The solution offers numerous advantages: with By-me, for example, energy and climate are controlled with great simplicity and can be supervised at all times by means of stylish touch screens that integrate perfectly with the interior decor of the home.The climate can be set, controlled and changed at will in order to create pleasant wellness scenarios. The energy can be managed intelligently to optimise consumption, especially in the presence of renewable sources such as photovoltaics. The single common goal is to promote energy saving while increasing climatic comfort.
With Well-contact Plus, the devices use the KNX standard (which guarantees complete interoperability) to dialogue with other systems that may be present in the building.This important characteristic enables the temperature and energy of any kind of building to be managed, supervised and optimised without altering the state of the building and without limiting its future development.
9
10
This intuitive indicator uses a graduated scale and dynamic display colour to indi-cate consumption values. It warns when the comfort temperature is exceeded to encourage greater energy awareness.
Ecometer function.
Intuitive interface.The touch screen interface allows you to rapidly change the system's operating parameters such as the fan-coil speed, the desired temperature and the thermostat operating mode.
To achieve ideal climatic comfort.Integration with home automation systems allows for comprehensive climate management in all buildings. This enables climate to be controlled either locally or centrally from a single station (including a remote station). Solutions for heating and cooling of buildings with two or four-pipe systems, both underfloor and with radiators, with fan-coils and split/multisplit systems.
CLIMATE
For all types of buildings.The new products can be installed in any kind of temperature control system, whether underfloor or with radiators, fan-coils or split/multisplit systems, in On/Off mode or with proportional control, and with 2 or 4 pipes by means of a neutral zone.
11
Climate can be controlled and external environmental parameters displayed centrally by means of touch screens of various sizes with a sophisticated design. A touch of the display is sufficient to set the ideal climate everywhere in the home, with the option of calling up easy-to-use preset comfort scenarios.
Centralised climate control.
Climate control can be performed room by room by means of elegant flush mounting thermostats or by means of sensors in-stalled in the various spaces. Thanks to the intuitive touch display of the thermostats and the internal sensor calibration function, temperature control is even more precise and comfort guaranteed.
Local temperature control.
What's in the air?
In rooms where an underfloor cooling system is present (a system with high thermal inertia that does not allow for rapid temperature changes), the innovative thermostat "boost" function allows fan-coils or towel warmers to be turned on automatically to rapidly establish the desired comfort temperature.
Controlling humidity.Thanks to the dedicated sensors, the home automation thermostats are automatically activated when the set threshold value is exceeded, activating air circulation or dehumidifiers present in the building to optimise the climate. In systems with underfloor cooling, the formation of condensation can also be prevented by controlling the dew point.
Setting hour by hour.
The temperature of each individual room can be set manually or programmed hour by hour on a weekly basis.
12
For smart energy management.The integration of home automation systems with new and renovated buildings allows for full control of all energy-related aspects, from power consumption monitoring through to photovoltaic control in single and three-phase systems. The smart solution.
Complete energy management, at a touch.
Displaying consumption values. Not just electrical.
There is no risk of blackouts: if the contractual threshold is exceeded, the home automation system decides to turn off certain loads according to pre-set priorities. Also available on three-phase networks.
Load control.Making overload blackouts a thing of the past.
ENERGY
Energy in the building is managed completely by means of touch screen, making it possible to constantly monitor all the values both by period - on an hourly, daily, weekly, monthly or even yearly basis - and by type of variable (kilowatt hour, euro, carbon dioxide emissions saved) so as to precisely define the energy profile of your home and take action when needed.
The new range - now also available for three-phase systems - introduces the ability to view both the energy consumed by single loads and non-electric energy consumption such as water and gas, enabling consumption accounting. The colour touch screens display energy usage clearly and continuously, promoting greater energy awareness and allowing you to take corrective action to optimise consumption levels.
12
13
The new devices are able to display the energy produced by a photovoltaic system, both locally and remotely using a smartphone. This is a very convenient feature for deciding how and when to use the energy produced.
Photovoltaics: displaying the generated energy.
Thanks to this sophisticated technology, the energy generated by the photovoltaic system during peak production time bands can be sent to selected electrical appliances to optimise consumption. This way, you will only need to purchase energy from the utility company in the evenings when no energy is produced.
Auto-consumption: management of self-produced energy.
The system can be managed and supervised in many different ways: directly at home via the touch screen or remotely using the By-web mobile app.
Supervision and centralised control: local or remote, using By-web.
15
CLIMA&ENERGY
SELECTION GUIDELINESTemperature control managementPower management
from page 16from page 16from page 20
SURFACE MOUNTING TIME-THERMOSTATS AND THERMOSTATS
from page 24
FLUSH MOUNTING TIME-THERMOSTATS AND THERMOSTATS
from page 38
BY-ME: THERMOSTATS AND POWERMANAGEMENT DEVICES
from page 62
WELL-CONTACT PLUS: THERMOSTATS ANDPOWER MANAGEMENT DEVICES
from page 98
INSTALLATION EXAMPLES OF STAND ALONE SYSTEMSSimple layoutsTemperature control and energy management layouts
from page 106from page 106from page 109
INSTALLATION EXAMPLES WITH BY-ME AND WELL-CONTACT PLUSBy-me temperature control layoutsBy-me energy management layoutsWell-contact Plus temperature control layouts
from page 111from page 111from page 115from page 119
INS
TALL
ATIO
N E
XA
MP
LES
W
ITH
BY-
ME
AN
DW
ELL
-CO
NTA
CT
PLU
S
SE
LEC
TIO
NG
UID
ELI
NE
SS
UR
FAC
E M
OU
NTI
NG
TI
ME
-TH
ER
MO
STA
TS
AN
D T
HE
RM
OS
TATS
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
WE
LL-C
ON
TAC
T P
LUS
: TH
ER
MO
STA
TS A
ND
DE
VIC
ES
BY-
ME
:TH
ER
MO
STA
TSA
ND
DE
VIC
ES
INS
TALL
ATIO
N E
XA
MP
LES
O
F S
TAN
D A
LON
E D
EVI
CE
S
Catalogue section
16
CLIMA&ENERGY
Cable control
ClimaChronoelectronic touch screen time-thermostat for ON/OFF and PID temperature control (heating and climate control), preset to display energy data via a power meter and specific interface, 1 multi-purpose programmable input, 5(2) A 230 V~ change-over relay output, powered by AA LR6 1.5 V batteries (not supplied)
ClimaRadioelectronic time-thermostat for heating and air conditioning, daily/weekly programming, manual/automatic/timed operation, 5(2) A 250 V~ change-over relay output, powered by battery AA LR6 1.5 V (not supplied)
ClimaThermoelectronic touch screen thermostat for ON/OFF and PID temperature control (heating and climate control), 1 multi-purpose programmable input, 5(2) A 230 V~ change-over relay output, powered by AA LR6 1.5 V batteries (not supplied)
Electronic thermostat for temperature control (heating and air conditioning), 5(2) A 230 V~ change-over relay output, powered by 2 AAA LR03 1.5 V batteries (not supplied)
Radiofrequency control
ClimaPiùelectronic slider time-thermostatheating and air conditioning, daily/weekly programming, manual/automatic/timed operation, powered by AA LR6 1.5 V batteries (not supplied)
ClimaRadioelectronic time-thermostatheating and air conditioning, daily/weekly programming, manual/automatic/timed operation, powered by AA LR6 1.5 V batteries (not supplied)
Integrated GSM control
ClimaPhoneGSM electronic time-thermostatheating and air conditioning with GSM telephone communicator for sending and receiving SMS messages, an auxiliary output channel and a digital input channel, daily/weekly programming, 5(2) A 250 V~ change-over relay output, power supply 120-230 V~
ClimaThermoelectronic touch screen thermostat for local or remote control (built-in GSM) of temperature (heating and air conditioning) in ON/OFF or PID mode, 1 input for external temperature sensor, 5(2) A 230 V~ change-over relay output, power supply 230 V~ 50/60 Hz, white LED backlighting
Temperature control: selection guidelinesStand alone surface mounting solutions
02910
01910 01910.14 01910.20
02905
02900
01911 01921.1
+
01910 01921.1
+
01910.14 01921.1
+
01910.20 01921.1
+
01913
02906
∆ Available while stocks last
17
CLIMA&ENERGY
Cable control with energy supervision
ClimaChronoelectronic touch screen time-thermostat for ON/OFF and PID temperature control (heating and climate control), preset to display energy data via a power meter and specific interface, 1 multi-purpose programmable input, 5(2) A 230 V~ change-over relay output, powered by AA LR6 1.5 V batteries (not supplied)
1-channel actuator-receiver,occupies 6 modules size 17.5 mm
4-channel actuator-receiver,occupies 6 modules size 17.5 mm
Power meter, 3 inputs for toroidal current sensor 01457, detectable power 50 W-10 kW, 1 RJ9 (4P4C) serial data output, installation on DIN rail (60715 TH35), occupies 1 module size 17.5 mm. Supplied with a toroidal current sensor 01457
Wired temperature sensor,4 m cable length
Temperature control: selection guidelinesStand alone surface mounting solutions
System components for DIN rail (60715 TH35)
02910 02915
+
Radiofrequency
Radiofrequency transmitter module, with spring contact connector
Base for 01910 time-thermostat, complete with bidrectional radiofrequency transmitter module, with built-in antenna, powered by 2 AA LR6 1.5 V batteries (not supplied)
Energy measurement
Power meter interface module with 3 toroidal sensor inputs, 1 serial data input
Accessories for surface mounting devices
01921.1
∆ 01930
02915
01923
01924
SE
LEC
TIO
NG
UID
ELI
NE
S
02960
02965
18
CLIMA&ENERGY
Eikon Arké PlanaElectronic touch screen time-thermostat for ON/OFF and PID temperature control (heating and air conditioning), 1 input for external temperature sensor, 1 program-mable multi-function input, 1 RJ9 (4P4C) input for power meter, 5(2) A 230 V~ change-over relay output, power supply 120-230 V~ 50-60 Hz, RGB LED back-lighting
Electronic touch screen thermostat for ON/OFF and PID temperature control (heating and air conditioning), 1 input for external temperature sensor, 1 program-mable multi-function input, 5(2) A 230 V~ change-over relay output, power supply 120-230 V~ 50-60 Hz, RGB LED back-lighting
Eikon Arké Idea Plana
Electronic time-thermostatfor heating and air conditioning with daily/weekly programming, remote ON/OFF input via phone dialler, 6(2) A 230 V~ change-over relay output, power supply 120-230 V~ 50-60 Hz
Electronic time-thermostatfor heating and air conditioning, daily/weekly programming, remote ON/OFF input via phone dialler, 5(2) A 250 V~ change-over relay output, powered by AA LR6 1.5 V batteries (not supplied)
Electronic thermostatfor heating and air conditioning, input for remote activation with energy-saving function, remote ON/OFF input via phone dialler, 6(2) A 230 V~ change-over relay output, power supply 120-230 V~ 50-60 Hz
Electronic thermostatfor heating and air conditioning, summer/off/winter switch, input for remote activation with energy-saving function, 6(2) A 230 V~ change-over relay output, power supply 120-230 V~ 50-60 Hz
Electronic thermostat for service sectorfor heating and air conditioning, input for remote activation with energy-saving function, input for switching between heating/air conditioning, 6(2) A 230 V~ change-over relay output, power supply 120-230 V~ 50-60 Hz
Eikon Arké Idea Plana
NTC electronic temperature sensor, 1 output
Electronic active humidity sensor, 1 output 0-10 V or 4-20 mA, power supply 12/24V
Wired temperature sensor, 4 m cable length
Power meter, 3 inputs for toroidal current sensor 01457, detectable power 15 W-10 kW, 1 RJ9 serial data output, installation on DIN rail (60715 TH35), occupies 1 x 17.5 mm module. Supplied with a toroidal current sensor 01457
144463 modules
14446.SL3 modules
194463 modules
19446.B3 modules
165763 modules
16576.B3 modules
204463 modules
20446.B3 modules
20446.N3 modules
144402 modules
14440.SL2 modules
194402 modules
19440.B2 modules
204402 modules
20440.B2 modules
20440.N2 modules
204412 modules
20441.B2 modules
20441.N2 modules
144452 modules
14445.SL2 modules
165753 modules
16575.B3 modules
204452 modules
20445.B2 modules
20445.N2 modules
029553 modules
029502 modules
Temperature control: selection guidelinesStand alone flush mounting solutions
Sensors for stand alone devices
20432.B1 module
204321 module
20430.N1 module
144321 module
14432.SL1 module
194321 module
19432.B1 module
144332 modules
14433.SL2 modules
194332 modules
19433.B2 modules
204332 modules
20433.B2 modules
20433.N2 modules
02965
∆ Available while stocks last
02960
For availability, please contact the sales network
19
CLIMA&ENERGY
For By-me system Eikon Arké Plana
Thermostat for touch screen home automation for ON/OFF, PWM and PID temperature control (heating and air conditioning) and dew point control, management of 2 and 4 pipe systems, 3 speed and proportional fan coil control, 1 input for electronic temperature sensor or wired temperature sensor, RGB LED backlighting
Eikon Arké Idea Plana
Thermostat for By-me home automation system room temperature control
Fan-coil thermostat for By-me home automation system three-speed automatic or manual fan-coil control
Sensors Eikon Arké Plana
Temperature probe for ON/OFF, PWM and PI temperature control (heating and air conditioning) and dew point control, management of 2 and 4 pipe systems, 3 speed and proportional fan coil control, 1 input for electronic temperature sensor or wired temperature sensor
For Well-contact Plus system Eikon Arké Plana
Touch screen electronic thermostat for 2 independent zone ambient temperature control (heating and air conditioning), KNX standard home automation, 1 NO relay output 4 A 24 V~, 1 input for electronic temperature sensor or wired temperature sensor, 1 programmable digital input, RGB LED backlighting
Eikon Arké Idea Plana
Electronic thermostat for ambient temperature control (heating and air conditioning) of 2 independent zones, KNX standard, 1 NO relay output 4 A 24 V~, 1 input for temperature sensor, 1 programmable digital input
Sensors Eikon Arké Plana
NTC electronic temperature sensor, 1 output
Electronic active humidity sensor, 1 0-10 V or 4-20 mA output, power supply 12/24V
Wired temperature sensor,4 m cable length
205142 modules
195142 modules
20514.B2 modules
19514.B2 modules
20514.N2 modules
169542 modules
145142 modules
16954.B2 modules
14514.SL2 modules
029512 modules
02951.B2 modules
029522 modules
02952.B2 modules
205132 modules
195132 modules
20513.B2 modules
19513.B2 modules
20513.N2 modules
169532 modules
16953.B2 modules
145132 modules
14513.SL2 modules
204302 modules
194302 modules
20430.B2 modules
19430.B2 modules
20430.N2 modules
169152 modules
16915.B2 modules
144302 modules
14430.SL2 modules
Temperature control: selection guidelinesFlush mounting solutions for automation systems
20432.B1 module
204321 module
20430.N1 module
144321 module
14432.SL1 module
194321 module
19432.B1 module
145381 module
195381 module
20538.B1 module
205381 module
20538.N1 module
14538.SL1 module
19538.B1 module
144332 modules
14433.SL2 modules
194332 modules
19433.B2 modules
204332 modules
20433.B2 modules
20433.N2 modules
02965
SE
LEC
TIO
NG
UID
ELI
NE
S
20
CLIMA&ENERGYEnergy management: selection guidelines
For By-me system Eikon Arké Plana
Actuator with relay output16 A 230 V~ 50 Hz with built-in current sensor
Interface for transmission of By-me commands to IR receiver, complete with 3 m cable
Power meter with built-in current sen-sor, detectable power up to 3680 W, for flush mounting
Pulse counter interface for detecting data from devices equipped with pulse output such as electricity, water and gas meters, for flush mounting
Flush mounting solutions for automation systems
145372 modules
14537.SL2 modules
205372 modules
20537.N2 modules
20537.B2 modules
195372 modules
19537.B2 modules
01451
01452
For DIN (60715 TH35) rail
Power meter, 3 inputs for toroidal current sensor 01457, 15 W-10 kW detectable power, 1 RJ9 serial data output, installation on DIN (60715 TH35) rail, occupies 1 module size 17.5 mm. Supplied with a toroidal current sensor 01457
Climate control device for heating systems, power supply 120-230 V~50/60 Hz, 3 inputs for PT100, PT1000 and NTC probes, 1 mixer valve control output, 1 0-10 V or (0)4-20 mA output, 8 A 230 V~ change-over relay output, occupies 6 modules size 17.5 mm
Actuator with 4 proportional analogue outputs (0)4-20 mA or 0-10 V with re-scalable maximum output voltage, power supply 120-230 V~ 50/60 Hz, By-me home automation, occupies 4 modules size 17.5 mm
Device with 3 analogue signal inputs, 1 0-10 V or 4-20 mA input, 1 input for wired or flush mounting NTC temperature sensor, 1 input for brightness sensor 01530, for By-me home automation, occupies 2 modules size 17.5 mm
Power meter, 3 inputs for toroidal current sensor, 25 W-100 kW detectable power, single-phase power supply 120-230 V 50/60 Hz three-phase 230/400 V 50/60 Hz, occupies 1 module size 17.5 mm. Supplied with a toroidal current sensor 01457
For DIN (60715 TH35) rail
Load control module, 3 inputs for toroidal current sensor, 25 W-100 kW detectable power, single-phase power supply 120-230 V 50/60 Hz three-phase 230/400 V 50/60 Hz, occupies 1 module size 17.5 mm. Supplied with a toroidal current sensor 01457
Actuator with 16 A change-over relay output 120-230 V~ 50/60 Hz with integrated current sensor, 1 input channel for toroidal residual current sensor, occupies 1 module size 17.5 mm. Supplied without toroidal residual current sensor
Lowered actuator with 16 A 120-230 V~ change-over relay output, button for local control, complete with removable spacer for installation on DIN (60715 TH35) rail, occu-pies 2 modules size 17.5 mm
Actuator with 4 16 A 120-230 V~ change-over relay outputs, buttons for local control, occupies 4 modules size 17.5 mm
Unit for implementing logic, mathematical, timing and messaging functions, for By-me home automation, configurable only with EasyTool Professional, occupies 1 module size 17.5 mm
Components for automation systems
02960
01465
01466
01467
01450
01455
01456
01850.2
For availability, please contact the sales network
20584.1.N1 module
20584.1.B1 module
20584.11 module
14584.1.SL1 module
14584.11 module
19584.11 module
19584.1.B1 module
01851.2
01468
21
CLIMA&ENERGYEnergy management: selection guidelines
By-me Eikon Arké Plana
Control and configuration unit, monochrome touch screen, 1 input for temperature sensor, supplied with accessory V51923 for installation on DIN (60715 TH35) rail- 3 modules. Complete with connector for front-panel programming RJ45, cable and accessory V51921 for installation on DIN (60715 TH35) rail
Power supply with 29 Vdc400 mA output, 230 V~50/60 Hz power supply, with decoupling coil, installation on DIN (60715 TH35) rail, occupies 2 modules size 17.5 mm
Power supply with 29 Vdc1280 mA output, 120-230 V~50/60 Hz power supply, with decoupling coil, installation on DIN (60715 TH35) rail, occupies 8 modules size 17.5 mm
Cable for Bus systems, halogen-free 2x0.50 mm2, rated voltage toward earth 400 V, suitable for installation with I power cables category, white - 100 m
Toroidal current sensor for load control and power metering, hole diameter 7.5 mm, 40 cm cable length
Toroidal current sensor for load control and power meter, hole diameter 19 mm, 40 cm cable length
Toroidal residual current sensor for power actuator, hole diameter 9 mm, 40 cm cable length
Weather station, KNX standard, power supply 12-32 Vdc or 12-24 Vac
Probes
Components for By-me system
Weather station
01546
01458
01457
01459
SE
LEC
TIO
NG
UID
ELI
NE
S
215093 modules
21509.B3 modules
21509.N3 modules
01840
01400
01401
22
CLIMA&ENERGY
Stand alone surface mounting devices Stand alone thermostat Stand alone flush mounting devices Automation flush mounting devices
TypeGSM
time- thermostatTouch screen
time-thermostatDigital
time-thermostatGSM
thermostatTouch screenthermostat
Electronic thermostat
Touch screentime-thermostat Touch screen thermostat By-me
Touch screen thermostatWell-contact Plus
Touch screen thermostat
Power supply230 V, 50/60 Hz
with buffer battery 3 V 3 V 230 V50/60 Hz 3 V 3 V 120/220 V
50/60 Hz120/220 V50/60 Hz 29 Vdc 29 Vdc
Control On/Off On/Off and PID On/Off On/Off and PID On/Off and PID On/Off On/Off and PID On/Off and PID On/Off and PID On/Off and PID
Display LCD Positive cap. LCD Positive cap. Positive cap. Inverse cap. Inverse cap. Positive cap. Positive cap.
Backlight White RGB RGB RGB RGB
Hot keysYes
(eco/output)Yes
(eco/output)Yes
(output)Yes
(eco)Yes
(output)Yes
(eco/output)
Protected mode Yes Yes(PIN)
Yes(PIN)
Yes(PIN)
Yes(PIN)
Yes(PIN)
Yes (from configuration on control unit or EasyToolPro)
Yes(from configuration on
ETS)
Ecometer Yes Yes Yes Yes(colour)
Yes(colour) Yes Yes
Off-set T° Yes Yes Yes Yes Yes Yes Yes
Configurable sensor input
Limitation display adjustment
Limitation display adjustment
Limitation display adjustment
Limitation display adjustment
Limitation display adjustment
Auxiliary inputs/outputs
1 alarm signal input1 output for auxiliary
relay
1 configurable input for: Nighttime reduction, Remote
activation, Summer/Winter
1 input for remote activation
1 configurable input for: Nighttime reduction, Remote
activation, Summer/Winter
1 configurable input for: Nighttime reduction, Remote activation,
Summer/Winter
1 configurable input for: Nighttime reduction, Remote activation,
Summer/Winter
1 input / 1 output with ETS configurable relay
Special functionsEnergy monitor
with module 02915 (optional)
Radiofrequency transmission with 01921.1 module
(optional)
Energy monitor(RS485) built in
Humidity display, fan-coil control, 2/4 pipe
management
Humidity display, fan-coil control, 2/4 pipe
management
Audio feedbackReady
(with module 02915) Yes Yes
ConfigurationYes
(with By-clima App via GSM)
Yes(with By-clima App
via GSM)
Yes(By-clima App via audio)
Yes (By-me 21509 control unit or EasyTool Professional software)
Yes(via ETS)
Control connectivity
Yes remote (with By-clima App via GSM)
Yes remote(with By-clima App
via GSM)
Yes: locally with touch screen; remotely with By-phone App
via GSM or By-me via IP)
Yes: locally with touch screen; remotely with KNX
By-web App via IP)
Installation Surface mounting Surface mounting Surface mounting Surface mounting Surface mounting Surface mounting Flush mounting, for Eikon, Arké and Plana
Flush mounting, for Eikon, Arké and Plana
Flush mounting, for Eikon, Arké and Plana
Flush mounting, for Eikon, Arké and Plana
02905
Comparison table for functionsTemperature control solutions
01913 02910 01910 02906
23
CLIMA&ENERGY
Stand alone surface mounting devices Stand alone thermostat Stand alone flush mounting devices Automation flush mounting devices
TypeGSM
time- thermostatTouch screen
time-thermostatDigital
time-thermostatGSM
thermostatTouch screenthermostat
Electronic thermostat
Touch screentime-thermostat Touch screen thermostat By-me
Touch screen thermostatWell-contact Plus
Touch screen thermostat
Power supply230 V, 50/60 Hz
with buffer battery 3 V 3 V 230 V50/60 Hz 3 V 3 V 120/220 V
50/60 Hz120/220 V50/60 Hz 29 Vdc 29 Vdc
Control On/Off On/Off and PID On/Off On/Off and PID On/Off and PID On/Off On/Off and PID On/Off and PID On/Off and PID On/Off and PID
Display LCD Positive cap. LCD Positive cap. Positive cap. Inverse cap. Inverse cap. Positive cap. Positive cap.
Backlight White RGB RGB RGB RGB
Hot keysYes
(eco/output)Yes
(eco/output)Yes
(output)Yes
(eco)Yes
(output)Yes
(eco/output)
Protected mode Yes Yes(PIN)
Yes(PIN)
Yes(PIN)
Yes(PIN)
Yes(PIN)
Yes (from configuration on control unit or EasyToolPro)
Yes(from configuration on
ETS)
Ecometer Yes Yes Yes Yes(colour)
Yes(colour) Yes Yes
Off-set T° Yes Yes Yes Yes Yes Yes Yes
Configurable sensor input
Limitation display adjustment
Limitation display adjustment
Limitation display adjustment
Limitation display adjustment
Limitation display adjustment
Auxiliary inputs/outputs
1 alarm signal input1 output for auxiliary
relay
1 configurable input for: Nighttime reduction, Remote
activation, Summer/Winter
1 input for remote activation
1 configurable input for: Nighttime reduction, Remote
activation, Summer/Winter
1 configurable input for: Nighttime reduction, Remote activation,
Summer/Winter
1 configurable input for: Nighttime reduction, Remote activation,
Summer/Winter
1 input / 1 output with ETS configurable relay
Special functionsEnergy monitor
with module 02915 (optional)
Radiofrequency transmission with 01921.1 module
(optional)
Energy monitor(RS485) built in
Humidity display, fan-coil control, 2/4 pipe
management
Humidity display, fan-coil control, 2/4 pipe
management
Audio feedbackReady
(with module 02915) Yes Yes
ConfigurationYes
(with By-clima App via GSM)
Yes(with By-clima App
via GSM)
Yes(By-clima App via audio)
Yes (By-me 21509 control unit or EasyTool Professional software)
Yes(via ETS)
Control connectivity
Yes remote (with By-clima App via GSM)
Yes remote(with By-clima App
via GSM)
Yes: locally with touch screen; remotely with By-phone App
via GSM or By-me via IP)
Yes: locally with touch screen; remotely with KNX
By-web App via IP)
Installation Surface mounting Surface mounting Surface mounting Surface mounting Surface mounting Surface mounting Flush mounting, for Eikon, Arké and Plana
Flush mounting, for Eikon, Arké and Plana
Flush mounting, for Eikon, Arké and Plana
Flush mounting, for Eikon, Arké and Plana
SE
LEC
TIO
NG
UID
ELI
NE
S
Comparison table for functions
02900 02955 02950 02951(02951.B white)
02952(02952.B white)
24
CLIMA&ENERGYClimaPhone: GSM electronic time-thermostat
Display "Mouse" button to control the basic functions
Base for surface mounting
AAA Ni-MH1.2 V rechargeable batteries (supplied)
Terminals
Buttons for program-ming the functions
Folding front cover
Inside cover
SIM card housing(SIM card not supplied)
Connector for01991
Input contact
Auxiliary relay
Boiler
LN
L IN N L 1 NO C NCN
120230 V~ IN
100 mAOUT
5(2) A1CU
01913 - Main characteristics• programming facilitated by By-clima smartphone app, available
for iOS, Android and WindowsPhone;• integrated GSM communicator with internal antenna that uses
SMS messages to:- manage time-thermostat operation;- configure the time-thermostat;- query the time-thermostat to determine its status;- switch the supplementary relay output on and off and query its
status;- query the state of the digital input;- redirect non-system SMS messages;
• warn of alarms via SMS that can be associated with the digital input; sending up to 8 different phone numbers;
• possibility of setting a password for access to the time-thermostat menus and make changes to its operation;
• connection with interface 01991 for programming with a PC using EasyTool software;
• 2 AAA NiMH 1.2 V rechargeable batteries for the power supply in case of power failure; in the absence of mains power and with the batteries initially charged, the time-thermostat remains fully functional (i.e. with the GSM module active) for approximately two hours;
• wall installation using expansion plugs or on flush-mounting boxes V71303 or on flush-mounting boxes with distance between centres of 60 mm;
• timed temperature setting;• 1 program for heating and 1 for air conditioning;
• 4 programmable temperature levels for heating and 4 for air conditioning (T1, T2, T3 and Tantifreeze);
• operating modes: Manual, Timed Manual, Automatic, Antifreeze, Off and Timed Switch-Off;
• protection class: IP30;• type of contact opening: micro-disconnection;• phone communication: GSM-GPRS, E-GSM 900, 1800 MHz
GPRS module class 10.
Compliance with standardsR&TTE directive,Standards EN 60730-1, EN 60730-2-7, EN 60730-2-9,EN 301 489-1, EN 301 489-7, EN 301 511
Technical datapower supply 120-230 V~, 50-60 Hzbackup power 2 AAA batteries Ni-MH 1.2 Vdisplayed temperature refresh every 20 sroom temperature display 0°C +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustable temperature differential from 0.1°C to 1°Cadjustment range in antifreeze mode from +4°C to +15°Cadjustment range in heating/air conditioning modes from +5°C to +35°C
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
clock error - ≤ ± 1 s a day operating temperature from 0°C to +40°C (indoor use)
Inputs120-230V~ power supply N, L1 digital input (alarm signalling) 120-230V~ N, L, IN, NSIM card housing (SIM card not supplied) SIM
Outputsfor auxiliary relay control 100 mA 120-230V~ L, 1
25
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
ClimaPhone: GSM electronic time-thermostat
Unlimited control with By-clima.The By-clima smartphone app allows the time-thermostat to be fully programmed and controlled by sending simple SMS messages. Available free of charge for iOS, Android and WindowsPhone operating systems.
Programming with EasyTool.In addition to the front buttons and SMS messages, ClimaPhone can also be configured using the EasyTool software included in the 01991 interface, which can perform the following operations via a PC:• configuring the time-thermostat by setting operating modes and parameters;• setting the parameters associated with the digital input and the supplementary
output;• customising identification of the digital input, supplementary output and relay
controlled by the time-thermostat by means of a text label;• setting the phone numbers to which the alarm SMS text messages are to be sent.
01991 interface for connecting to the PC
By-clima applicationfor smartphone
01913
01913
130
90
35,5
GSM electronic time-thermostat01913 Electronic time-thermostat for room temperature control (heating and air conditioning) with built-in GSM phone dialler. Daily/weekly programming,
5(2) A 230 V~ change-over relay output, 1 additional output and 1 digital input, remote control via SMS, supply voltage 120-230 V~, for surface mounting, white
SU
RFA
CE
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
26
CLIMA&ENERGYClimaChrono: touch screen time-thermostat02910 - Touch screen time-thermostatThe battery-powered device is suitable for controlling heating and air conditioning systems. IT features a capacitive button interface and user-friendly functions to facilitate energy saving. The time-thermostat can be connected to the energy sensor 02960 (not supplied) via optional card 02915 to display electrical energy con-sumption and production and the corresponding data logs (up to 3 years), as well as instantaneous data of total power and the voltage of each individual phase. By consulting the energy consumption (or generation), you can monitor up to 3 separate phases (with com-mon neutral), for a maximum of 10kW per phase. The device does not activate/deactivate loads according to the detected powers but only performs monitoring and emits audible alarms; card 02915 is provided with a buzzer to warn when the set threshold is exceeded. The device has a multipurpose input that can be configured to ac-tivate nighttime reduction mode or adjustment with comfort set-points or to set summer/winter operating mode.
Main functions• temperature control algorithms: ON/OFF or PID selectable via
user interface:- the ON/OFF algorithm is the control that turns heating off when
the set temperature is exceeded by a given threshold value (the opposite in the case of air conditioning) and turns it back on again when the room temperature returns to below the set tem-perature;
- the PID is an advanced algorithm capable of keeping the temperature of a room stable; it works by turning the system on or off so as to gradually increase or decrease the heating (or cooling) power of the system; ideal for underfloor systems, the algorithm must be suitably calibrated according to the type of room and system;
• "Ecometer" function: by means of specific items it provides a general indication of expected consumption, thereby facilitating energy saving measures.
This consumption estimate is based on a comparison between the current set temperature value and an "average" consumption value set on the time-thermostat;
• communication with energy probe 02960 via additional card 02915 to be installed on the time-thermostat base for reading, displaying and storing energy data (power, energy);
Main characteristics• 4" touch screen display;• configurable in heating/air conditioning mode (winter/summer);• Off-set mode (T°): for calibrating the temperature read by the
thermostat; you can add or subtract (in intervals of 0.1°C) a fixed amount from the temperature detected by the time-thermostat to make it equal, for example, to that of a sample thermometer;
• use of the "hour meter": the number of hours that the thermostat relay has been on (equal to the number of hours of operation of the heating/air conditioning system);
• operating modes: Off, Antifreeze (heating only), Away, Manual, Au-tomatic, Timed Manual;
• set-point and away activation hotkeys;• 6 settable temperature set-points/offsets (Economy, Comfort,
Manual, Away, Antifreeze, Reduction);• restriction on local interface access via PIN and configurable multi-
function input;• batteries not supplied;• battery life: more than a year in normal conditions of use;• type of action: 1.B;• degree of pollution: 2 (normal);• protection class: IP20.
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-2-7, EN 60730-2-9
Technical datapower supply with 2 AA LR6 1.5 V batteries 3 Vdcnominal pulse voltage 4000 Vdisplayed temperature refresh every 5 sroom temperature display 0°C +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustable temperature differential from 0.1°C to 1°Cadjustment range in antifreeze mode from +4°C to +15°Cadjustment range in heating/air conditioning modes from +5°C to +35°C
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
clock error - ≤ ± 1 s a day operating temperature from 0°C to +40°C (indoor use)
Inputsmulti-function input + -
Outputs
relay with clean changeover contact 5(2) A 230 V~ NO, NC, C
02910 - Display
Room temperature
Heating mode
"Away" button
"Increase" button
"Decrease" button
Settingsmenu
Back button
Automatic
Day of the week
Energy savingindicator
Comfort temperature
Clock
Daily program
02910 - Display
Room temperature
Heating mode
"Away" button
"Increase" button
Energy consumption log"Decrease" button
Settings menu
Back button
Automatic
Watt
Energy indicator
Clock
Daily program
27
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Large 4" touch screen display
Inside cover
Relay module for controls via cable with spring contact
Interface module (optional) for power meter 02915 (optional)
Base for surface mounting
Connecting cable from module 02915 (optional) to power meter 02960
Connecting conductors from relay module to the air conditioning units, for use via cable
ClimaChrono: touch screen time-thermostatTouch screen time-thermostat02910 Electronic touch screen time-thermostat for ON/OFF and PID temperature control (heating and climate control), preset to display energy data via
a power meter and specific interface, 1 multi-purpose programmable input, 5(2) A 230 V~ change-over relay output, powered by AA LR6 1.5 V batteries (not supplied), for surface mounting, white
02910
02910
135
4”
95
83,5
60
Drilling templates (in mm)
SU
RFA
CE
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
Interior view of time-thermostat, from rear, with battery compartment
AAA LR031.5 V batteries (not supplied)
28
ClimaRadio: time-thermostat
Connecting cable from radiofre-quency module to the telephone communicator.
Radiofrequency transmission module 01921.1 with spring contact
Connecting conduc-tors from relay mod-ule to the telephone communicator, for use via cable
Base for surface mounting
Buttons for pro-gramming the functions
Folding front cover
Internal cover for module housing
Display
"Mouse" button to con-trol the basic functions
Interior view of time-thermo-stat, from rear, with battery
compartment
Connecting conduc-tors from relay module to the air conditioning units, for use via cable
Relay module for controls via cable with spring contact
• type of contact opening: micro-disconnection;• wall installation using expansion plugs or flush-mounting boxes
V71303 or flush-mounting boxes with distance between centres of 60 mm.
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-1, EN 60730-2-7, EN 60730-2-9
01910 - Main characteristics• phone dialler input that can be used for remote control of time-
thermostat;• type of setting: ON/OFF;• possibility of radio-frequency connection to actuators 01923
and 01924 after replacing the relay module with the transmitter module 01921.1;
• main functions:- daily temperature setting with 15 minute steps;- 3 programmable temperature levels for heating + 3 temperature
levels for air conditioning + 1 antifreeze level;- weekly programming;- 1 automatic program that can be set by the user (for both
heating and air conditioning);- possibility of forcing the program by changing the temperature manually;- adjustment for heating and air conditioning;- antifreeze function;- possibility of turning off with timer;- possibility of turning on/off with telephone actuator;- display in degrees Celsius or Fahrenheit;
- device reset; • batteries not supplied;• battery life: more than a year in normal conditions of use;• protection class: IP30;
Technical datapower supply with 2 AA LR6 1.5 V batteries 3 Vdcdisplayed temperature refresh every 20 sroom temperature display 0°C +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustable temperature differential from 0.1°C to 1°Cadjustment range in antifreeze mode from +4°C to +15°Cadjustment range in heating/air conditioning modes from +5°C to +35°C
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
clock error - ≤ ± 1 s a day operating temperature from 0°C to +40°C (indoor use)
Inputstelephone dialler with no-voltage contact + -
Outputs
relay with clean changeover contact 5(2) A 250 V~ NO, NC, C
Radio base complete with module for bidi-rectional radiofrequen-cy transmission.01930
CLIMA&ENERGY
29
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
ClimaRadio: time-thermostat
130
90
22
83,5
60
Drilling templates (in mm)
Electronic time-thermostatElectronic time-thermostat for room temperature control (heating and air conditioning), 5(2) A 250 V~ change-over relay output, power supply with AA LR6 1.5 V batteries (not supplied), for surface mounting
01910white
01910.14anthracite
01910.20silver
SU
RFA
CE
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
30
CLIMA&ENERGYClimaThermo: GSM touch screen thermostat
• remote interaction is facilitated by the By-clima smartphone app available for iOS, Android and WindowsPhone, which automati-cally sends coded SMS messages to activate and deactivate the thermostat and interrogate it about data, the environment and other functions;
• configurable in Heating/Air Conditioning mode (winter/summer);• Off-set mode (T°): for calibrating the temperature read by the
thermostat; you can add or subtract (in intervals of 0.1°C) a fixed amount from the temperature detected by the time-thermostat to make it equal, for example, to that of a sample thermometer;
• "hour meter" display: the number of hours that the thermostat re-lay has been on (equal to the number of hours of operation of the heating/air conditioning system);
• operating modes: Off, Antifreeze (heating only), Away, Manual and Nighttime reduction;
• 5 settable temperature set-points/offsets (Comfort, Manual, Away, Antifreeze, Reduction);
• local interface access protected by PIN;• protection class: IP40.
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-2-7, EN 60730-2-9
Large 4" backlit touch screen display
Inside cover
Relay module for controls via cable with spring contact
Base for surface mounting
Connecting conductors from relay module to the air conditioning units, for use via cable
Interior view of time-thermostat, from rear, with SIM card housing (SIM card not supplied)
Technical datapower supply 230 Vac, 50/60 Hzmains power draw 3 VAroom temperature display 0°C +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustable temperature differential from 0.1°C to 1°Cadjustment range in antifreeze mode from +4°C to +10°Cadjustment range in heating/air conditioning modes from +10°C to +35°C
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
operating temperature from 0°C to +40°C (indoor use)Inputspower supply L, N
external temperature probe (02965)
Outputsrelay with clean changeover contact 5(2) A 250 V~ NO, NC, C
02906 - GSM touch screen thermostatThe electronic touch screen thermostat is designed to control room temperature by means of the control circuit of the burner or circula-tion pump (heating) or the control circuit of the air conditioner (air conditioning), ensuring an ideal temperature; it features an incorpo-rated GSM communicator for remote control, capacitative buttons and a graphic interface that uses special screens to help the user manage the system.The device has an input for the external temperature probe 02965 (not supplied).
Main functions • temperature control algorithms: ON/OFF or PID selectable via
user interface:- the ON/OFF algorithm is the control that turns heating off when
the set temperature is exceeded by a given threshold value (the opposite in the case of air conditioning) and turns it back on again when the room temperature returns to below the set tem-perature;
- the PID is an advanced algorithm capable of keeping the temperature of a room stable; it works by turning the system on or off so as to gradually increase or decrease the heating (or cooling) power of the system; ideal for underfloor systems, the algorithm must be suitably calibrated according to the type of room and system;
• "Ecometer" function: by means of specific items it provides a general indication of expected consumption, thereby facilitating energy saving measures.
This consumption estimate is based on a comparison between the current set temperature value and an "average" consumption value set on the time-thermostat.
Main characteristics• 4" touch screen display;• Programmable via smartphone or tablet after downloading the ded-
icated By-clima app from the website gestione-energia.vimar.it/it;
31
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
ClimaThermo: GSM touch screen thermostatGSM touch screen thermostat02906 Electronic touch screen thermostat for local or remote control (built-in GSM) of temperature (heating and air conditioning) in ON/OFF or PID mode, 1
input for external temperature sensor, 6(2) A 230 V~ change-over relay output, power supply 230 V~ 50/60 Hz, white LED backlighting, for surface mounting, white
02906
83,5
Drilling templates (in mm)
135
4”
95
02906
Device menu Use mode menu Temperature change menu Daily programming menu
SU
RFA
CE
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
Unlimited control with By-clima.The By-clima smartphone app allows the time-thermostat to be fully programmed and controlled by sending simple SMS messages. Available free of charge for iOS, Android and WindowsPhone operating systems. By-clima application
for smartphone
32
CLIMA&ENERGYClimaThermo: touch screen thermostat02905 - Electronic touch screen thermostatThe device is powered by 2 AA LR6 1.5 V batteries and is suitable for controlling heating and air conditioning systems.IT is equipped with capacitative buttons and a graphic user inter-face with special screens to help the user operate the system and make energy savings. The device has a multipurpose input that can be configured to activate nighttime reduction mode or adjustment with comfort set-points or to set summer/winter operating mode.
Main functions• temperature control algorithms: ON/OFF or PID selectable via
user interface:- the ON/OFF algorithm is the control that turns heating off when
the set temperature is exceeded by a given threshold value (the opposite in the case of air conditioning) and turns it back on again when the room temperature returns to below the set tem-perature;
- the PID is an advanced algorithm capable of keeping the tem-perature of a room stable; it works by turning the system on or off so as to gradually increase or decrease the heating (or cooling) power of the system; ideal for underfloor systems, the algorithm must be suitably calibrated according to the type of room and system;
• "Ecometer" function: by means of specific items it provides a general indication of expected consumption, thereby facilitating energy saving measures.
This consumption estimate is based on a comparison between the current set temperature value and an "average" consumption value set on the thermostat.
Main characteristics• 4" touch screen display;• configurable in heating/air conditioning mode (winter/summer);• Off-set mode (T°): for calibrating the temperature read by the
thermostat; you can add or subtract (in intervals of 0.1°C) a fixed amount from the temperature detected by the time-thermostat to make it equal, for example, to that of a sample thermometer;
• use of the "hour meter": the number of hours that the thermostat relay has been on (equal to the number of hours of operation of the heating/air conditioning system);
• operating modes: Off, Antifreeze (heating only), Away, Manual and Nighttime reduction;
• 5 settable temperature set-points/offsets (comfort, manual, away, antifreeze, reduction);
• restriction on local interface access via PIN and configurable multi-function input;
• two modes of use:- Easy mode in which the user can set only the desired tempera-
ture set point without having to confirm the entered value and without accessing the configuration;
- Normal mode in which the user has access to all thermostat use menus;
• batteries not supplied;• battery life: more than a year in normal conditions of use;• protection class: IP20.
Compliance with standardsLV Directive, EMC Directive,Standard EN 60730-2-9
Technical datapower supply with 2 AA LR6 1.5 V batteries 3 Vdcnominal pulse voltage 4000 Vdisplayed temperature refresh every 5 sroom temperature display 0°C +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustable temperature differential from 0.1°C to 1°Cadjustment range in antifreeze mode from +4°C to +15°Cadjustment range in heating/air conditioning modes from +5°C to +35°C
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
clock error - ≤ ± 1 s a day operating temperature from 0°C to +40°C (indoor use)
Inputsmulti-function input + -
Outputs
relay with clean changeover contact 5(2) A 250 V~ NO, NC, C
02905 - Display
Room temperature
Heating mode
"Away" button
"Increase" button
"Decrease" button
Settingsmenu
Set-point reduction button
Ecometer icon with indication of consumption
33
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
ClimaThermo: touch screen thermostatElectronic touch screen thermostat02905
Electronic touch screen thermostat for ON/OFF and PID temperature control (heating and air conditioning), 1 multi-purpose programmable input, 6(2) A 230 V~ change-over relay output, powered by AA LR6 1.5 V batteries (not supplied), for surface-mounting, white
02905
Large 4" touch screen display
Inside cover
Relay module for controls via cable with spring contact
Base for surface mounting
Interior view of time-thermostat, from rear, with battery compartment
AAA LR031.5 V batteries (not supplied)
135
4”
95
02905
83,5
60
Drilling templates (in mm)
SU
RFA
CE
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
34
CLIMA&ENERGY
R e l a y module
Rotary knob
green LED for air conditioning
red LED for heating
Base for surface mounting or installation on 2 and 3 module flush mounting boxes for hollow walls (art. V71701 and V71703) and masonry walls (art. V71001 and V71303)
Selector for type of action (day/nighttime reduction)
Operating mode selector (heating/air conditioning)
Inside covers
Clima: electronic thermostat02900 - Electronic thermostatThe electronic thermostat is designed to control room temperature by acting on the control circuit of the burner or circulation pump (heating) or on the control circuit of the air conditioner (air conditioning), with the possibility of activating the "energy saving" function.The device is powered by 2 AAA LR03 1.5 V batteries (not supplied).
Main functions• "energy saving" function: the set temperature is reduced by 4°C
(heating) or increased by 4°C (air conditioning).
Main characteristics• configurable in heating/air conditioning mode (winter/summer);• type of setting: ON/OFF;• type of contact opening: micro-disconnection;• type of action: 1.C;• degree of pollution: 2 (normal);• batteries not supplied;
• battery life: more than a year in normal conditions of use;• protection class: IP20;• class II appliance: ; • surface mounting using expansion plugs.
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-1, EN 60730-2-9
Technical datapower supply with 2 AAA LR03 1.5 V batteries 3 Vdcadjustment range +10°C - +35°Cnumber of manual cycles 3,000number of automatic cycles 10,000nominal pulse voltage 4,000 Vsoftware class and structure Atracking index PTI 175operating temperature from 0°C to +40°C (indoor use)
Outputs
relay with clean changeover contact 5(2) A 250 V~ NO, NC, C
Interior view of time-thermostat, from rear, with battery compartment
AAA LR03 1.5 V batteries (not supplied)
35
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Clima: electronic thermostatElectronic thermostat02900 Electronic thermostat for temperature control (heating and air conditioning), 6(2) A 230 V~ change-over relay output, power supply with 2 AAA LR03
1.5 V batteries (not supplied), surface mounting, white
02900
02900
2520
15
1030
122
113
68 68,5
SU
RFA
CE
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
36
CLIMA&ENERGY
• restriction on local interface access via PIN and configurable multi-function input;
• relay output with clean change-over contacts: 5(2) A 230 V~: with no power supply, the relay moves into position C-NC;
• protection class: IP20;• class II appliance: ;• type of action: 1.B.U.;• degree of pollution: 2 (normal).
Compliance with standardsLV directive, EMC Directive, Standards EN 60730-2-7, EN 60730-2-9
Stand alone flush mounting devices02955 - Electronic touch screen time-thermostatThe device, equipped with a capacitive touch screen interface with colour backlighting, is ideal for controlling heating and air condi-tioning systems via relay output C, NC, N/O. IT is equipped with a built-in buzzer, a multi-function input that can be configured to acti-vate nighttime reduction mode, to activate the setting with comfort set-point or to define the summer/winter operating mode, and an input for managing an external temperature probe (not supplied). It can also be connected to the energy probe 02960 (not supplied) to display the consumption/production of electrical energy and the corresponding historical data. Simplified programming with the By-clima smartphone application, available for iOS, Android and WindowsPhone. The time-thermostat is a universal 3-module device for Eikon, Arkè and Plana series.
Main functions• temperature control algorithms: ON/OFF or PID selectable via
user interface:- the ON/OFF algorithm is the control that turns heating off when
the set temperature is exceeded by a given threshold value (the opposite in the case of air conditioning) and turns it back on again when the room temperature returns to below the set temperature;
- the PID is an advanced algorithm capable of keeping the tem-perature of a room stable; it works by turning the system on or off so as to gradually increase or decrease the heating (or cooling) power of the system; ideal for underfloor systems, the algorithm must be suitably calibrated according to the type of room and system;
• "Ecometer" function: by means of specific items it provides a general indication of expected consumption, thereby facilitating energy saving measures.
This consumption estimate is based on a comparison between the current set temperature value and an "average" consumption value set on the time-thermostat;
• menu for selecting display background colour: in addition to the backlighting colours of each residential series, it is also pos-sible to choose any colour from the entire RGB colour range or set "Eco" mode in which the display colour intuitively reflects the set-point;
• communication with energy probe 02960 for reading, display and storage of energy data (power, energy and phase voltage).
Main characteristics• programmable via smartphone or tablet after downloading the
dedicated By-clima app from the website gestione-energia.vimar.it/it;
• configurable in heating/air conditioning mode (winter/summer);• Off-set (T°) mode: for calibrating the temperature read by the
thermostat; you can add or subtract (in intervals of 0.1°C) a fixed amount from the temperature detected by the time-thermostat to make it equal, for example, to that of a sample thermometer;
• temperature probe input: see Operation of 02950;• use of the "hour meter": the number of hours that the time-
thermostat relay has been on (equal to the number of hours of operation of the heating/air conditioning system);
• anti black-out "acoustic alert": the time-thermostat is able to generate and report alarm conditions relating to the use of the external temperature probe and monitoring of electrical energy consumption;
• operating modes: Off, Antifreeze (heating only), Away, Manual and Nighttime reduction;
• 5 set-points/settable temperature offsets (comfort, manual, away, anti-freeze, reduction) and 1 limiting threshold (external probe);
Technical datapower supply 120-230 V~, 50/60 Hzmains power draw 1 VAoperating temperature range from 0°C to 40°C (-T40)
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
adjustment range in heating mode from +5°C to +30°Cadjustment range in air conditioning mode from +10°C to +35°Cnominal pulse voltage 4000 Voperating temperature from -5°C to +40°C (indoor use)
Inputspower supply L, N
external temperature probe (02965)
RJ9 for energy probe 02960 +, A, B, -multifunction IN
Outputsrelay with clean changeover contact 5(2) A 250 V~ NO, NC, C
02955 - Front view and connections
NC, NO, C
Multi-function input
External temperature
sensorterminals
Connector RJ9 for energy probe
02960
Power supply
Room temperatureHeating mode
Automatic
Day of the week Energy saving indicator
Clock
Daily programme
indication ring
02955 - Display
Room temperature
Heating mode
"Away" button
Increase/navigation button
Decrease/navigation button
Hot key
Energy log navigation
Automatic
Watt
Settings menu
Clock
Daily program
37
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Stand alone flush mounting devices
44,8
35,3EIKONARKÉPLANA
02955
Electronic time-thermostat02955 Electronic touch screen time-thermostat for ON/OFF and PID temperature control (heating and air conditioning), 1 input for external temperature
sensor, 1 programmable multi-function input, 1 RJ9 input for power meter, 5(2) A 230 V~ change-over relay output, supply voltage 120-230 V~ 50-60 Hz, RGB LED backlighting, to be completed with Eikon, Arké or Plana cover plates, grey - 3 modules
Examples of RGB display colours coordinated with the Eikon, Arké and Plana series.
With Eikon Evo cover plate and amber backlighting With Arké cover plate and blue backlighting With Plana cover plate and green backlighting
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
Unlimited programming with By-clima.The app allows the time-thermostat to be programmed rapidly by sending the audio signal directly from the app to the product. It is a new and simple way to set the preferred functions and the time program. Available free of charge for iOS, Android and WindowsPhone operating systems.
By-clima application for smartphone
Device menu "Appearance" and "sounds" menu Temperature change menu Daily programming menu
blue teal green yellow red
low consumption optimum consumption excessive consumption
NoteThe ECOmeter mode allows the backlighting colour to be set. Depending on the set temperature, it is associated with the estimated energy consumption level; it does not display the colour according to the temperature measured at that moment but solely according to the set-point.
38
CLIMA&ENERGYStand alone flush mounting devices02950 - Electronic touch screen thermostatThe device is equipped with a capacitive touch screen interface with colour backlighting and allows for heating or air conditioning adjustment with ON/OFF or PID actuation. IT also has a multifunc-tional input that can be configured to activate nighttime reduction mode or adjustment with comfort set-points or to set summer/winter operating mode. The thermostat is a universal device for the Eikon, Arkè and Plana series.
Main functions• temperature control algorithms: ON/OFF or PID selectable via
user interface:- the ON/OFF algorithm is the control that turns heating off when
the set temperature is exceeded by a given threshold value (the opposite in the case of air conditioning) and turns it back on again when the room temperature returns to below the set temperature;
- The PID is an advanced algorithm capable of keeping the tem-perature of a room stable; it works by turning the system on or off so as to gradually increase or decrease the heating (or cooling) power of the system; ideal for underfloor systems, the algorithm must be suitably calibrated according to the type of room and system;
• "Ecometer" function: by means of specific items it provides a general indication of expected consumption, thereby facilitating energy saving measures.
This consumption estimate is based on a comparison between the current set temperature value and an "average" consumption value set on the thermostat;
• menu for selecting display background colour: in addition to the backlighting colours of each residential series, it is also pos-sible to choose any colour from the entire RGB colour range or set "Eco" mode in which the display colour intuitively reflects the set-point;
Main characteristics• configurable in heating/air conditioning mode (winter/summer);• Off-set mode (T°): for calibrating the temperature read by the
thermostat; you can add or subtract (intervals of 0.1°C) a fixed amount from the temperature detected by the time-thermostat to make it equal, for example, to that of a sample thermometer;
• use of "hour meter": the number of hours that the thermostat relay has been on (equal to the number of hours of operation of the heating/air conditioning system);
• operating modes: Off, Antifreeze (heating only), Away, Manual and Nighttime reduction;
• 5 set-points/settable temperature offsets (comfort, manual, away, anti-freeze, reduction) and 1 limiting threshold (external probe);
• restriction on local interface access via PIN and configurable multi-function input;
• relay output with clean change-over contacts: 5(2) A 230 V~: with no power supply, the relay moves into position C-NC;
• protection class: IP20;• class II appliance: ;• type of action: 1.B;• degree of pollution: 2 (normal).
OperationThe electronic touch screen thermostat can be connected to an external temperature probe and can operate in the following modes:- adjustment mode (the external probe is used to adjust the ambi-
ent temperature);- display mode (the thermostat's internal probe is used for adjust-
ment and the external probe is used only in display mode);- limiting mode (for floor heating systems, the probe inside the
thermostat is used to adjust the ambient temperature and the external probe has the sole purpose of limiting the floor heating delivery temperature).
Compliance with standardsLV directive, EMC Directive, Standards EN 60730-2-9
Technical datapower supply 120-230 V~, 50/60Hzmains power draw 1 VAoperating temperature range from 0°C to 40°C (-T40)
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
adjustment range in heating mode from +5°C to +30°Cadjustment range in air conditioning mode from +10°C to +35°Cnominal pulse voltage 4000 Voperating temperature from -5°C to +40°C (indoor use)
Inputspower supply L, N
external temperature probe (02965)
multifunction INOutputsrelay with clean changeover contact 5(2) A 250 V~ NO, NC, C
02950 - Front view and connections
NC, NO, C
Multifunction input
External temperature sensor terminals
Power supply
Room temperature
Heating
Ecometer icon with consumption indication
02950 - Display
Room temperature
Heating mode
Increase/navigation button
Decrease/navigation button
Hot key/exit
Confirm and hot key/set-point reduction
Settings menu
Ecometericon with
indication of consumption
39
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Stand alone flush-mounting devices
48
38,5
EIKONARKÉPLANA
Electronic touch screen thermostat02950 Electronic touch screen thermostat for ON/OFF and PID temperature control (heating and air conditioning), 1 input for external temperature sensor,
1 programmable multi-function input, change-over relay output 5(2) A 230 V~, power supply 120-230 V~ 50-60 Hz, RGB LED backlighting, to be completed with Eikon, Arké or Plana cover plates, grey - 2 modules
Examples of RGB display colours coordinated with the Eikon, Arké and Plana series.
With Eikon Total Look cover plate and amber backlighting With Arké cover plate and blue backlighting With Plana cover plate and green backlighting
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
02950black
blue teal green yellow red
low consumption optimum consumption excessive consumption
NoteThe ECOmeter mode allows the backlighting colour to be set. Depending on the set temperature, it is associated with the estimated energy consumption level; it does not display the colour according to the temperature measured at that moment but solely according to the set-point.
40
CLIMA&ENERGY
Electronic time-thermostatThe appliance is designed to control room temperature by acting on the supply circuit of the burner or circulation pump (heating) or on the supply circuit of the air conditioner (air conditioning), ensur-ing an ideal temperature, every day, throughout the week. The numerous functions allow for use of pre-stored fixed programs or creation of new ones. The large display shows the room tempera-ture, day, time, system operating status and the daily profile set for the current program. All parameters can be programmed simply and intuitively by means of self-guided navigation from the interac-tive menus (all the instructions are shown on the display), using the 4 buttons located on the front of the device.
Main functions• daily temperature setting with 20 minute steps;• 3 programmable temperature levels for heating + 3 temperature
levels for air conditioning;• weekly programming;• 2 fixed programs and 2 user-settable programs (for both heating
and air conditioning);• possibility of forcing the program by changing the temperature;• programming maintained in the event of a power failure;• adjustment for heating and air conditioning;• antifreeze function;• possibility of turning off with timer;• possibility of turning on and off with a phone dialler;• instructions in 5 languages (Italian, English, French, Spanish,
German);• device reset;• self-diagnostics: automatically activated at regular intervals dur-
ing normal use, this function checks the presence of the power supply voltage, the state of the temperature sensor, the state of the display driver, the efficiency of the EEPROM memory and the efficiency of the backup stage;
• keypad lock via password with 3-digit PIN to block access to all the functions of the device and protect its operation and program-ming (for example, if it is installed in a public location).
Main characteristics• front controls: “Esc”/“Mod”/“No”, “”, “”, “Set”/“ok”/“Yes”;• power reserve for clock: about 20 days, by means of recharge-
able lithium buffer battery;• output: relay with clean changeover contact 6 (2) A 230 V~;• type of setting: ON/OFF;• temperature sampling frequency:
- every 5 s, with average of acquired values 20 s;- instantaneous, when a parameter is changed by the user;
• software calibration: ability to change the probe reading with soft-ware calibration (±3°C max) to adapt the measurement to each specific installation condition;
• timed backlit display, activated by pressing one of the four but-tons;
• type of contact opening: micro-disconnection;• protection class: IP40;• class II appliances: ;
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-1, EN 60730-2-7, EN 60730-2-9
Technical datapower supply 120-230 V~ ±10% 50/60 Hzmains power draw 1 Woperating temperature range from 0°C to 40°C (-T40)
accuracy of reading in heating mode - ≤ ±0.5°C between +15°C and +25°C- ≤ ±0.8°C at the extremes
accuracy of reading in heating mode - ≤ ±0.5°C between +20°C and +30°C- ≤ ±0.8°C at the extremes
displayed data refresh every 20 sroom temperature display from +0°C to +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustment range in heating/air conditioning modes from +5°C to +35°Cadjustment range in antifreeze mode from +4°C to +15°Cadjustable temperature differential adjustable from 0.1°C to 1°Cclock error ≤ ±1 s a daynumber of manual cycles 3,000number of automatic cycles 100,000nominal pulse voltage 4000 Vtracking index PTI175degree of pollution 2 (normal)software class Atype of action 1BUoperating temperature from -5°C to +40°C (indoor use)
Inputspower supply L, N
telephone actuator
Outputsrelay with clean changeover contact 6(2) A 230 V~ NO, NC, C
Connections with motorized valves
CLOSED
OPEN
attuatoretelefonico
Connections with circulation pumps, burners, solenoid valves and control by means of telephone dialler
CHRONOTHERM
Example of daily programming
Day of the week
Daily pattern of the current program
Current time
Room temperature
Program running
State of output
Stand alone flush-mounting devices
Phoneactuator
41
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
44,837
46,5
49
49,7
36
EIKON
20445grey
20445.NNext
20445.Bwhite
14445white
14445.SLSilver
PLANA
Electronic time-thermostatElectronic time-thermostat for room temperature control (heating and air conditioning), daily/weekly programming, remote ON/OFF input via phone dialler, 6(2) A 230 V~ change-over relay output, power supply 120-230 V~ 50-60 Hz - 2 modules
Stand alone flush mounting devices
42
CLIMA&ENERGYStand alone flush mounting devicesElectronic time-thermostatThe device is designed for control and daily/weekly programming of room temperature (heating and air conditioning).It can act on the supply circuit of the burner or circulation pump (heating) or on the supply circuit of the air conditioner (air condition-ing).All parameters can be programmed simply and intuitively by means of self-guided navigation from the interactive menus (all the instruc-tions are shown on the display), using the 4 buttons located on the front of the device.
Main functions• daily temperature setting with 20 minute steps;• 3 programmable temperature levels for heating + 3 temperature
levels for air conditioning;• weekly programming;• 2 fixed programs and 2 user-settable programs (for both heating
and air conditioning);• possibility of forcing the program by changing the temperature;• programming maintained in the event of a power failure;• adjustment for heating and air conditioning;• antifreeze function;• possibility of turning off with timer;• possibility of turning on and off with a phone dialler;• instructions in 5 languages (Italian, English, French, Spanish,
German);• device reset;• self-diagnostics: automatically activated at regular intervals dur-
ing normal use, this function checks the presence of the power supply voltage, the state of the temperature sensor, the state of the display driver, the efficiency of the EEPROM memory and the efficiency of the backup stage;
• keypad lock via password with 3-digit PIN to block access to all the functions of the device and protect its operation and program-ming (for example, if it is installed in a public location).
Main characteristics• front controls: “Esc”/“Mod”/“No”, “”, “”, “Set”/“ok”/“Yes”;• power reserve for clock: about 10 days, by means of CR2032
type battery;• type of setting: ON/OFF;• temperature sampling frequency:
- every 5 s, with average of acquired values 20 s;- instantaneous, when a parameter is changed by the user;
• software calibration: ability to change the probe reading with soft-ware calibration (±3°C max) to adapt the measurement to each specific installation condition;
• timed backlit display, activated by pressing one of the four but-tons;
• anti-removal locking using the screw provided;• type of contact opening: micro-disconnection;• protection class: IP40;• class II appliances: ;• can be installed in boxes with minimum depth of 46 mm.
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-1, EN 60730-2-7, EN 60730-2-9
Technical datapower supply 120-230 V~, 50/60 Hzmains power draw 1 VAoperating temperature range from 0°C to 40°C (-T40)
accuracy of reading in heating mode - ≤ ±0.5°C between +15°C and +25°C- ≤ ±0.8°C at the extremes
accuracy of reading in heating mode - ≤ ±0.5°C between +20°C and +30°C- ≤ ±0.8°C at the extremes
displayed data refresh every 20 sroom temperature display from +0°C to +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustment range in heating/air conditioning modes from +5°C to +35°Cadjustment range in antifreeze mode from +4°C to +15°Cadjustable temperature differential adjustable from 0.1°C to 1°Cclock error ≤ ±1 s a daynumber of manual cycles 3,000number of automatic cycles 100,000nominal pulse voltage 4000 Vtracking index PTI175degree of pollution 2 (normal)software class Atype of action 1BUoperating temperature from -5°C to +40°C (indoor use)
Inputspower supply L, Ntelephone actuator INPUT
Outputsrelay with clean changeover contact 6(2) A 230 V~ NO, NC, C
LN
CHIUDE
APREU1
Connections with motorized valves
Example of daily programming
Day of the week
Daily pattern of thecurrent program
Current time
Room temperature
Program running
State of output
LN
U1
Connections with circulation pumps, burners and solenoid valves
Terminals for connection to telephone dialler
43
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
56,5
40IDEA
16575.Bwhite
16575grey
Electronic time-thermostatElectronic time-thermostat for room temperature control (heating and air conditioning), daily/weekly programming, 6(2) A 230 V~ change-over relay output, power supply 120-230 V~ 50-60 Hz - 3 modules
Stand alone flush mounting devices
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
44
CLIMA&ENERGYStand alone flush-mounting devices3 module electronic time-thermostatThe appliance is designed to control room temperature by acting on the control circuit of the burner or circulation pump (heating) or on the control circuit of the air conditioner (air conditioning), ensuring an ideal temperature, every day, throughout the week.The large display shows the room temperature, day, time, system operating status and the daily profile set for the current program.The time-thermostat can also be controlled remotely by means of a telephone dialler to turn the system on and off.
Main functions• timed temperature setting;• 3 programmable temperature levels for heating + 3 temperature
levels for air conditioning + 1 antifreeze level;• weekly programming;• 1 automatic program that can be set by the user (for both heat-
ing and air conditioning);• possibility of forcing the program by changing the temperature
manually;• adjustment for heating and air conditioning;• antifreeze function;• possibility of turning off with timer;• possibility of turning on with a phone actuator;• display in degrees Celsius or Fahrenheit;• device reset.
Main characteristics• output: relay with clean changeover contact 5(2) A 250 V~;• type of setting: ON/OFF;• removable front (fitted with CR2032 type buffer battery, supplied);• type of contact opening: micro-disconnection;• protection class:
- IP40 with anti-removal screw inserted;- IP20 with anti-removal screw not inserted;
• class II appliances: with SELV circuits.
Releasing front panelThe time-thermostat is equipped with a removable front panel that enables the settings and programming to be changed even when the appliance has been removed from its seat.
Compliance with standardsLV Directive, EMC DirectiveStandards EN 60730-1, EN 60730-2-7, EN 60730-2-9
Technical datapower supply with 2 AA LR6 1.5 V batteries 3 Vdcmains power draw 1 VAoperating temperature range from 0°C to 40°C (-T40)
reading accuracy - ≤ ±0.5°C between +15°C and +30°C
- ≤ ±0.8°C at the extremesdisplayed data refresh every 20 sroom temperature display from +0°C to +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustment range in heating/air conditioning modes from +5°C to +35°Cadjustment range in antifreeze mode from +4°C to +15°Cadjustable temperature differential adjustable from 0.1°C to 1°Cclock error ≤ ±1 s a daynumber of manual cycles 3,000number of automatic cycles 100,000nominal pulse voltage 4000 Vtracking index PTI175degree of pollution 2 (normal)software class Atype of action 1BUoperating temperature from +0°C to +40°C (indoor use)
Inputspower supply L, Ntelephone actuator INPUT
Outputsrelay with clean changeover contact 5(2) A 250 V~ NO, NC, C
COMFORT CONTROL 1
2
COMFORT CONTROL
20446 - Extracting removable front panel
20446 - Front view, controls and display
COMFORT CONTROL
1 3 5 7 9 11 13 15 17 19 21 23
T1T3T
C/F°PROGOFFTEMP
LUN
CDelete or return to the
previous screen
P Access to programming
mode
FSelect operating mode
OKConfirm or continue to the next screen
MouseTo set numerical values
and for scrolling
1 3 5 7 9 11 13 15 17 19 21 23
T1T3T
C/F°PROGOFFTEMP
LUN
Temperature values
Room temperature
Daily pattern of the current programHeating or air
conditioningTime of day
Current time
Day of the week
20446 - Example of programming
45
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Stand alone flush mounting devices
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
3 module electronic time-thermostatElectronic time-thermostat for room temperature control (heating and air conditioning), daily/weekly programming, remote ON/OFF input via phone dialler, 5(2) A 250 V~ change-over relay output, powered by AA LR6 1.5 V batteries (supplied) - 3 modules. Not suitable for installation in Isoset IP40 and IP55 enclosures
43
53,8
67,3
49
EIKON
20446grey
20446.NNext
20446.Bwhite
67,3
49
42
53,8
14446white
14446.SLSilver
PLANA
56,5
40
16576grey
16576.Bwhite
IDEA
53,8
42,5 67,3
49
19446.Bwhite
19446grey
ARKÉ
LN
U1CLOSED
OPEN
Electrical connections to control motorized valves
LN
U1
Electrical connections to control circulation pumps, solenoid valves, etc. and control via telephone dialler
Connection with telephone actuator
46
CLIMA&ENERGYStand alone flush mounting devicesElectronic thermostat for residential sectorThe appliance is designed to control room temperature by acting on the control circuit of the burner or circulation pump (heating) or on the control circuit of the air conditioner (air conditioning). All the parameters are programmed with the 4 buttons on the front of the appliance.
Main functions• selection from 3 temperature levels: comfort, reduced, antifreeze;• possibility of selecting timed reduced temperature;• possibility of turning off or turning off with timer;• selecting heating or air conditioning;• possibility of turning on and off with a phone dialler;• forcing nighttime reduction with remote control;• display in degrees Celsius or Fahrenheit;• saving all the settings (10 years).
Main characteristics• output: relay with clean changeover contact 6(2) A 250 V~;• type of contact opening: micro-disconnection;• type of setting: ON/OFF;• protection class: IP40;• class II appliances: .
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-1, EN 60730-2-9
LN
U1
attuatoretelefonico
Electrical connections to control circulation pumps and solenoid valves and control via telephone dialler
Electrical connections to control motorized valves and remote control for nighttime reduction
LN
U1
OPENS
CLOSES
TIMER
Used to set a time for the selected operating mode.
It is also the configuration key
Air conditioning
Heating
Room temperature
Unit of measurement (Celsius/Fahrenheit)
AntifreezeSystem off
Timed operation(manual, off, nighttime reduction)
Nighttime reduction
Decrease displayed value (tempera-ture or time)
Change operating mode
Increase displayed value (temperature or time)
20440 - Front view, controls and display
Technical datapower supply 120-230 V~ 50/60 Hzmains power draw 1 VAoperating temperature range from 0°C to 40°C (-T40)
reading accuracy - ≤ ±0.5°C between +15°C and +30°C
- ≤ ±0.8°C at the extremesdisplayed data refresh every 30 sroom temperature display from +0°C to +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustment range in heating/air conditioning modes from +5°C to +35°Cadjustment range in antifreeze mode from +0°C to +15°Cadjustable temperature differential adjustable from 0.1°C to 1°Cclock error ≤ ±1 s a daynumber of manual cycles 3,000number of automatic cycles 100,000nominal pulse voltage 4000 Vtracking index PTI175degree of pollution 2 (normal)software class Atype of action 1Boperating temperature from +0°C to +40°C (indoor use)
Inputspower supply L, N
telephone actuator
Outputsrelay with clean changeover contact 6(2) A 250 V~ NO, NC, C
Phoneactuator
47
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Stand alone flush mounting devices
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
Electronic thermostat for residential sectorElectronic thermostat for room temperature control in residential applications (heating and air conditioning), input for remote activation of energy saving function, input for remote ON/OFF via phone dialler, 6(2) A 230 V~ change-over relay output, supply voltage 120-230 V~ 50/60 Hz - 2 modules
49
44,837
46,5EIKON
20440grey
20440.NNext
20440.Bwhite
48
CLIMA&ENERGYStand alone flush mounting devicesElectronic thermostatThis device is designed for controlling room temperature (heating or air conditioning).It can act on the supply circuit of the burner or circulation pump (heating) or on the supply circuit of the air conditioner (air conditioning).
Main characteristics• output: relay with clean changeover contact 6(2) A 230 V~;• type of setting: ON/OFF;• with the knob at the minimum position the “antifreeze” function is
activated (+6°C);• terminal for remote activation of “energy saving” function (with
possibility of enabling timer);• “energy saving” function: the set temperature is reduced by 4°C
(heating) or increased by 4°C (air conditioning);• front control of comfort temperature by means of graduated knob;• 3-position front switch:
- OFF position: the thermostat is off;- position : the thermostat is set for the “heating” function;- position : the thermostat is set for the “air conditioning”
function;• controllable loads: - purely resistive loads : 8 A 230 V~; • two-colour green/yellow LED :
- the green colour indicates that the relay output is not active (the set temperature has been reached);
- the yellow colour indicates that the relay output is active (the set temperature has not been reached);
In any case the illuminated LED (green or yellow) indicates the presence of the power supply;
• green LED : if illuminated it indicates that the “energy saving” function is activated;
• type of contact opening: micro-disconnection;• protection class: IP40;• class II appliance: .
Technical datapower supply 120-230 V~ 50/60 Hzmains power draw 3 VAtemperature differential 1 °Cadjustment range from +10°C to +30°Cnumber of manual cycles 3,000number of automatic cycles 100,000software class Atype of action 1Btracking index PTI175degree of pollution 2 (normal)degree of pollution 2nominal pulse voltage 4000 Voperating temperature from +0°C to +40°C (indoor use)
Inputspower supply L, N
energy saving
Outputsrelay with clean changeover contact 6(2) A 250 V~ NO, NC, C
N
U1Pompe di circolazione,bruciatori, elettrovalvole
Valvolamotorizzata
N
APRE
CHIUDE
L L
Electrical connections to control circulation pumps and solenoid valves
N
U1Pompe di circolazione,bruciatori, elettrovalvole
Valvolamotorizzata
N
APRE
CHIUDE
L L
Electrical connections to control motorized valves and remote control for nighttime reduction
14440 - Front view
Temperature setting
LED indicating relay state and/or presence of power supply
Air conditioning/heating switch
"Energy saving" LED activated
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-1, EN 60730-2-9
Motorizedsolenoid valve
CIRCULATION PUMPS, HEATERS, SOLENOID VALVES
OPENS
CLOSES
49
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
Stand alone flush mounting devicesElectronic thermostatElectronic thermostat for room temperature control (heating and air conditioning), summer/off/winter switch, input for remote activation of energy-saving function, 6(2) A 230 V~ change-over relay output, power supply 230 V~ 50/60 Hz - 2 modules
52,2
36
14440white
14440.SLSilver
PLANA
53,9
37 44,8
49
19440.Bwhite
19440grey
ARKÉ
50
CLIMA&ENERGYStand alone flush mounting devicesElectronic thermostat for service sectorThe appliance is designed to control room temperature by acting on the control circuit of the burner or circulation pump (heating) or on the control circuit of the air conditioner (air conditioning). All the parameters are programmed with the 4 buttons on the front of the appliance. With the 2 remote controls it is possible to centralize the summer/winter function and temperature reduction (typical application in ho-tels and offices with control from the reception or technical room).
Main functions• selection from 3 temperature levels: comfort, reduced, antifreeze;• possibility of selecting timed reduced temperature; • possibility of turning off or turning off with timer;• remote control of the heating/air conditioning function;• remote control of the reduction function;• display in degrees Celsius or Fahrenheit;• saving all the settings;• possibility of entering password with 3-digit PIN to block access
to configuration menu.
Main characteristics• output: relay with clean changeover contact 6(2) A 250 V~;• type of setting: ON/OFF;• type of contact opening: micro-disconnection;• protection class: IP40;• class II appliances: .
Technical datapower supply 120-230V~ 50/60 Hzmains power draw 1 VAoperating temperature range from 0°C to 40°C (-T40)
reading accuracy - ≤ ±0.5°C between +15°C and +30°C
- ≤ ±0.8°C at the extremesdisplayed data refresh every 30 sroom temperature display from +0°C to +40°Creading resolution 0.1°Csetting resolution 0.1°Cadjustment range in heating/air conditioning modes from +5°C to +35°Cadjustment range in antifreeze mode from +0°C to +15°Cadjustable temperature differential adjustable from 0.1°C to 1°Cclock error ≤ ±1 s a daynumber of manual cycles 3,000number of automatic cycles 100,000nominal pulse voltage 4000 Vtracking index PTI175degree of pollution 2 (normal)software class Atype of action 1Boperating temperature from +0°C to +40°C (indoor use)
Inputspower supply L, N
switching between heating/air conditioning
energy saving
Outputsrelay with clean changeover contact 6(2) A 230 V~ NO, NC, C
Configuration button
Air conditioning
Heating
Room temperature
Unit of measurement (Celsius/Fahrenheit)
Antifreeze.System off
Timed operation. (manual, off, nighttime reduction)
Nighttime reduction
Protected operation
Decrease displayed value (temperature or time)
Change operating mode
Increase displayed value (temperature or time)
20441 - Front view, controls and display
LN
U1
interruttore
Electrical connections to control circulation pumps, burners and solenoid valves and remote control by means of heating/air conditioning switch (e.g. general key control in technical room)
LN
U1
interruttore
OPENS
CLOSES
Electrical connections for control of motorized valves and remote control of nighttime reduction (e.g. guest in room presence switch or centralized timer set to different times from work times)
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-1, EN 60730-2-9
SWITCH
SWITCH
51
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Stand alone flush mounting devices
FLU
SH
MO
UN
TIN
G
TIM
E-T
HE
RM
OS
TATS
A
ND
TH
ER
MO
STA
TS
Electronic thermostat for service sectorElectronic thermostat for room temperature control in service sector applications (heating and air conditioning), input for remote activation of energy saving function, input for remote switching of heating/air conditioning, 6(2) A 230 V~ change-over relay output, supply voltage 120-230 V~ 50/60 Hz - 2 modules
49
44,837
46,5EIKON
20441grey
20441.NNext
20441.Bwhite
52
CLIMA&ENERGYClimaRadio: time-thermostat accessories01921.1 - Transmitter module, with spring contact connectorReplaces relay modules on time-thermostats 01910 and 01911, for radio transmission of commands to air conditioning devices.
Main characteristics• dimensions: 81x23.7x10.1 mm;• installation: inside the time-thermostat or thermostat;• antenna: integrated into the circuit;• internal connector for connection to phone dialler with actuator
and dedicated cable 01921.C.
Technical datapower supply (from time-thermostat or thermostat) 3 Vdcfrequency 433.92 MHzfree field radio range 120 moperating temperature from -5°C to +40°C (indoor use)
01930 - Bidirectional radio baseReplaces base of time-thermostat 01910 and allows for bidirec-tional radiofrequency transmission of main operating modes and setting with actuators and with GSM communicator 01941, com-plete with communication interface 01931.
Main characteristics• installation: replacing time-thermostat base cover;• antenna: integrated into the circuit;• possibility of connecting to the time-thermostat relay module for
direct control via cable of the temperature control systems, or radiofrequency connection to the 1 and 4 channel bidirectional actuators;
• possibility of data exchange and reception of commands from GSM communicator using internal communication interface;
• protection class: IP30;• batteries not supplied;• battery life: approx. 1 year in normal conditions of use;• dimensions: 130x90x14 mm.
01910Time-thermostat
01930Bidirectional radio base
Built-in antenna
1.5 V AA batteries
01910 - 01930: Coupling
Technical datapower supply with 2 AA LR6 1.5 V batteries 3 Vdcfrequency 868 MHzaverage radio transmission range in a closed space 30 mradiofrequency communication technology Z-WaveTM
operating temperature from 0°C to +40°C (indoor use)
∆ Available while stocks last
53
CLIMA&ENERGYClimaRadio: time-thermostat accessories
01921.1
Transmitter module for thermostat and time-thermostat01921.1 Radiofrequency transmitter module, with spring contact connector
Bidirectional radio base for time-thermostat∆ 01930 Base for time-thermostat 01910, complete with bidrectional radiofrequency transmitter module, with built-in antenna, powered by 2 AA LR6 1.5 V
batteries (not supplied)
Connection
Spring connector
UseIf you wish to use a radio actuator, it is possible to remove the relay module for cable connection present in the base of the time-thermostat 01910 and insert it in the dedicated housing in the bidirectional radio base 01930.
∆ 01930
Internal cover for module housing
01930Bidirectional radio base.
01910Time-thermostat
Relay module for controls via cable
AC
CE
SS
OR
IES
54
CLIMA&ENERGYAccessories for time-thermostats and thermostats
02915 - Power meter interface moduleWhen installed on time-thermostat 02910 and interconnected with the power meter 02960, the device allows for supervision of instantaneous energy consumption and production on the display.
Main characteristics• can be installed on surface-mounting time-thermostat 02910.
02960 - Power meterWhen interconnected with time-thermostats 02955 and 02910 (by means of module 02915), the device is able to measure instantaneous consumption and production of electrical energy and save the data over time. The power meter can be connected to single-phase and three-phase lines and is supplied with a current probe for measuring the power of a phase; the power on the other phases can be measured by purchasing another two current probes (01457).The data (instantaneous power, accumulated daily/weekly/monthly/annual energy and voltage per phase) can be displayed by means of surface-mounting time-thermostat 02910 and flush-mounting time-thermostat 02955.
Main characteristics• the device performs three types of measurements:
- measurement of the true root mean square (rms) voltage on each phase (if enabled by viewer art. 02955 or 02910);
- measurement of the true root mean square power on each phase (if enabled by viewer). The value can be positive or negative depending on the direction of the current through the sensor, so it is possible to measure both the consumption and production values of the electric energy;
- measurement of 3 separate voltages/powers (the voltages all referring to the same neutral);
• to connect the probe to the time-thermostat use a cable cat. 5e or higher;
• can be connected to surface-mounting time-thermostat 02910 and 3-module flush-mounting time-thermostat 02955;
• installation on DIN rail (60715 TH35): 1 module size 17.5 mm.
Compliance with standardsLV directive, Standards EN 61010-1, EN 61010-2-030,EMC directive, Standards EN 61000-6-1, EN 61000-6-3
Technical datapower supply with single-phase systems 120 Vac, 50/60 Hz
230 Vac, 50/60 Hz
power supply with three-phase systems 230/400 V, 50/60 Hz127/220 V, 50/60 Hz
measurable current per phase 50 A max
measurable powers 50 W - 10 kW at 400/230 V50 W - 6 kW at 127/220 V
maximum power drawn from the grid 1 VApower measurement accuracy ± 5%operating temperature from 0°C to +40°C (indoor use)
Inputspower supply L1, L2, L3, NRJ9 for module 02915 +, A, B, -for current sensors S1, S2, S3
A
B
C
D
02960ENERGYMETER
02960 - Front view and connections
A: LED signalling synchronisation with time-thermostatB: connector RJ9 for interface module 02915C: inputs for current sensorsD: terminals for three-phase line connection
Wired temperature sensorDevice to be used with thermostat 02950 and time-thermostat 02955 to display the temperature of the room where the product is installed.
Main characteristics• sensor NTC Beta=3900;• cable length: 4 m.
Technical dataresistance 25° 10 KΩviewable temperature on supervisors from -10°C to +70°C
Res
iste
nza
KΩ
0-50
50
100
150
200
250
300
350
400
50 100
NTC_minNTC_nominaleNTC_max
150
Temperatura °C
02965 - Resistance / temperature graph
Res
ista
nce
kΩ
Temperature °C
nominal
55
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Accessories for time-thermostats and thermostats
Power meter interface module02915 Power meter interface module with 3 toroidal sensor inputs, 1 serial data input
Power meter02960 Power meter, 3 inputs for toroidal current sensor 01457, 50 W-10 kW detectable power, 1 RJ9 (4P4C) serial data output, installation on DIN
(60715 TH35) rail, occupies 1 module sized 17.5 mm. Supplied with a toroidal current sensor 01457
02960
02915
Module 02915Base for surface mount-ing of time-thermostat Power meter
02960
Connector RJ9
Netsafe 5e UTP cable
02965
Wired temperature sensor02965 Wired temperature sensor, cable length 4 m
AC
CE
SS
OR
IES
56
CLIMA&ENERGYAccessories for time-thermostats and thermostatsElectronic temperature sensorThe device integrates with the By-me home automation system for temperature and energy management; it is managed using control unit 21509 and touch screens 21554, 21511, 21512, 20511.1, 19511 and 14511.1 to display the temperature of the room where the products are installed.
Main characteristics• maximum length of cable connecting sensor to devices: 60 m.
Technical dataresistance 25° 10 KΩviewable temperature on supervisors from -10°C to +70°C
Res
iste
nza
KΩ
0-50
50
100
150
200
250
300
350
400
50 100
NTC_minNTC_nominaleNTC_max
150
Temperatura °C
20432 - Resistance / temperature graph
For availability, please contact the sales network
Electronic active humidity sensorTemperature control device with the following functions: maintaining humidity below a desired threshold and preventing condensation in underfloor cooling systems. It measures the relative humidity in the room and sends the information via an analog 0-10 V voltage signal or 4-20 mA current signal.
Main characteristics• dual insulation from the power supply grid;• for the maximum measurement precision, install the device at a
height of about 1.5 m above the floor on an internal wall;• do not install in corners of rooms, in alcoves, behind bookshelves
or curtains or near doors, windows, forced air flows or sources of heat;
• max length of connecting cable to receiving device: 100 m. Use 2x0.5mm² twisted cable (art.01840);
• protection class: IP20.
ConfigurationThe output analog signal mode can be selected by means of a dedicated jumper on the rear of the sensor; set it to 0-10 V or to 4-20 mA to obtain the respective output signal mode.
Compliance with standardsEMC Directive, Standard EN 60730-2-13
Technical data
power supply 12-24 V~ 50 Hz, 12-32 Vdc SELV
maximum power draw at input 1 Wrange of humidity without condensation 10-90 RH%
typical humidity measurement precision in still air at 20°C and 50 RH% ± 3 RH%
operating temperature from -5°C to +45°C (indoor use)viewable range on touch screen supervisors from 10 to 90 RH%
Inputspower supply V+, -
Outputsthermostat RH+, -
Conversion tablevoltage 0-10 V current 4-20 mA
conversion function RH% = Voltage[V] x 10
RH% =(Current[mA]–4) x 6.25
external load limits Minimum 1000Ω Maximum 500Ω
20433 - Front view and connections
RH+
0-10 V 4-20 mA
JumperV+-Terminals:V+: power supply;- : power supply and output reference;RH+: output.
Jumper configuration:
Voltage setting Current setting
Res
ista
nce
kΩ
Temperature °C
nominal
57
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Accessories for time-thermostats and thermostats
20432.Bwhite
14432white
19432grey
20432grey
20432.NNext
14432.SLSilver
19432.Bwhite
22,3
49
24,434,7
34,7
23,4 22,3
49
35,2
24,4 22,2
49
EIKON
PLANA
ARKÉ
Electronic temperature sensorElectronic temperature sensor, 1 output
20433.Bwhite
20433grey
20433.NNext
47,8
44,9
49
10,8EIKON
Electronic active humidity sensorElectronic active humidity sensor, 1 0-10 V or 4-20 mA output, supply voltage 12/24 V - 2 modules. Can be integrated with the By-me home automation system via 01467
14433white
14433.SLSilver
48,2
44,8
49
12,2PLANA
19433grey
19433.Bwhite
48,7
44,8
49
11,7ARKÉ
AC
CE
SS
OR
IES
58
CLIMA&ENERGYDIN (60715 TH35) rail devices01923 - 1-channel actuator-receiverThe device allows for radio reception of commands from the time-thermostat and thermostat for air conditioning appliances.
Main characteristics• antenna: 17 cm rigid wire to be positioned vertically; a 433 MHz
external antenna can be connected to the terminal using a coaxial cable if the antenna needs to be positioned at a distance or if reception problems occur;
• LED indicating the intensity of the radio signal;• type of contact opening: micro-disconnection;• pollution situation: normal;• protection class: IP40;• class II appliances: ;• installation: on DIN rail (60715 TH35), size 6 modules.
Compliance with standardsLV, EMC, R&TTE Directives,Standards EN 60730-1, EN 60730-2-9,EN 300 220-3, EN 301 489-03
01924 - 2-channel actuator-receiverAllows for radio reception of commands from the time-thermostat and thermostat for air conditioning appliances.
Main characteristics• antenna: 17 cm rigid wire to be positioned vertically; a 433 MHz
external antenna can be connected to the terminal using a coaxial cable if the antenna needs to be positioned at a distance or if reception problems occur;
• LED indicating the intensity of the radio signal;• type of contact opening: micro-disconnection;• pollution situation: normal;• protection class: IP40;• class II appliances: ; • installation: on DIN rail (60715 TH35), size 6 modules.
Compliance with standardsLV, EMC, R&TTE Directives,Standards EN 60730-1, EN 60730-2-9,EN 300 220-3, EN 301 489-03
01924RX ACTUATOR
6(2)A 250 V~
1B
ON
CONF.Clima
230V~ 50/60Hz OUT 1 OUT 2 OUT 3 OUT 4L N C NO NC C NO NC C NO NC C NO NC
LN
Collegamenti elettrici per comando di pompe di circolazione, elettrovalvole, etc.
01924 - Connections
Technical datapower supply 230 V~ ±10% 50-60 Hzpower draw 2 VAreceiver ASK 433.92 MHzsensitivity approx. 106 dBmnumber of automatic cycles 100,000type of action 1Btracking index PTI175operating temperature from - 0°C to 55°C (indoor use)
Inputspower supply N, L
antenna
Outputs
1 relay 6(2) A 250 V~ with clean changeover contact NC, NO, C
Technical datapower supply 230 V~ ±10% 50-60 Hzpower draw 2 VAreceiver ASK 433.92 MHzsensitivity approx. 106 dBmnumber of automatic cycles 100,000type of action 1Btracking index PTI175operating temperature from - 0°C to 55°C (indoor use)
Inputspower supply N, L
antenna
Outputs
4 relay 6(2) A 250 V~ with clean changeover contact NC, NO, C
Electrical connections for the controlof circulation pumps, solenoid valves, etc.
59
CLIMA&ENERGYDIN (60715 TH35) rail devices
01924
01923
1-channel actuator-receiver01923 1-channel actuator-receiver, installation on DIN (60715 TH35) rail, occupies 6 modules sized 17.5 mm
4-channel actuator-receiver01924 4-channel actuator-receiver, installation on DIN (60715 TH35) rail, occupies 6 modules sized 17.5 mm
AC
CE
SS
OR
IES
60
CLIMA&ENERGY
Compliance with standardsEMC Directive, LV Directive,Standards EN 50428, EN 50491
By-me: thermostats and devices for energy managementElectronic thermostatThe electronic thermostat integrates with the By-me home automa-tion system for temperature control in 2 or 4 pipe systems (heating/air conditioning) and neutral zone (only in 4 pipe systems), with a boost function to activate a second source and reach the desired comfort temperature more rapidly. The thermostat is equipped with an RGB backlit display and 6 capacitative buttons to control temperature set point, fan coil speed and configuration of the ther-mostat operating modes; the display colour can be adjusted by means of control unit (21509) or EasyTool Professional software. The thermostat is a universal 2 module device for Eikon, Arkè and Plana series.
Main functions• temperature control algorithms: ON/OFF or PID selectable via user
interface:- the ON/OFF algorithm is the control that turns heating off when
the set temperature is exceeded by a given threshold value (the opposite in the case of air conditioning) and turns it back on again when the room temperature returns to below the set tem-perature;
- the PID is an advanced algorithm capable of keeping the temperature of a room stable; it works by turning the system on or off so as to gradually increase or decrease the heating (or cooling) power of the system; ideal for underfloor systems, the algorithm must be suitably calibrated according to the type of room and system;
• the RGB display colour can be:- fixed with colour of choice;- coordinated with residential series backlighting;
or using the "Ecometer" function, it can intuitively reflect the expected level of consumption in the system relative to the standard value (see note on the facing page);
• "boost" function enables the comfort temperature to be reached more rapidly in the presence of a second source (e.g. a fan-coil) and only if the difference between the measured temperature and the set-point is greater than a settable threshold.
Main characteristics• RGB backlit touch screen display with configurable colours;• display of the unit of measurement associated with the device;• display of the relative humidity of a room;• possibility of connecting an external temperature NTC sensor
(20432, 19432, 14432 or 02965): maximum length of sensor connecting cable to the devices: 60 m. Use a twisted cable with a minimum cross-section of 0.5 mm2 (01840);
• device compatible only with control unit 21509 or EasyTool Professional software (01992);
• installation: flush or surface mounting (with surface mounting box 09975…).
Technical datapower supply from By-me Bus 29 Vdcabsorption from By-me Bus 5 mAadjustment range in heating mode from +5°C to +30°Cadjustment range in air conditioning mode from +10°C to +35°Coperating temperature from 0°C to +40°C (indoor use)
InputsTP bus Bus + -
electronic temperature sensor
For availability, please contact the sales network
02951 - Front view and connections
BUS lineExternal temperature sensor terminals
Room temperature
Heating
Automatic
Operation setup button
Fan-coil setting button
Up / increase button
Down / decrease button
Room relative humidity
Fan-coil speed
61
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
By-me: thermostats and devices for energy management
48
44,8
49
9,5EIKONARKÉPLANA
02951.Bwhite
02951black
Electronic thermostatThermostat for touch screen home automation for ON/OFF, PWM and PID temperature control (heating and air conditioning), 2 and 4 pipe system management, 3 speed and proportional fan-coil control, 1 input for NTC wired or flush mounting temperature sensor, RGB LED backlighting, to be completed with Eikon, Arké or Plana cover plates - 2 modules
Examples of RGB display colours coordinated with the Eikon, Arké and Plana series.
With Eikon Chrome cover plate and amber backlighting With Arké cover plate and blue backlighting With Plana Silver cover plate and green backlighting
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
blue teal green yellow red
low consumption optimum consumption excessive consumption
NoteThe ECOmeter mode allows the backlighting colour to be set. Depending on the set temperature, it is associated with the estimated energy consumption level; it does not display the colour according to the temperature measured at that moment but solely according to the set-point.
62
CLIMA&ENERGY
Funzionamentoprotetto
Temperatura ambiente
Unità di misura (Celsius/Fahrenheit)
AntigeloImpianto spento
Funzionamento temporizzato(manuale, off, riduzione notturna)
Riduzione notturnaRiscaldamento
Condizionamento
Funzionamento automatico
20514 - Display
ThermostatThe device integrates with the By-me home automation system for temperature control and energy management and is suitable for controlling ambient temperature (heating and air conditioning). It can be controlled by the control unit in "time-thermostat" mode or can manage a zone independently in "thermostat" mode.
Main characteristics• adjustment range: - heating +5 - +30°C; - air conditioning +10 - +35°C;• device not compatible with proportional actuators (01466);• installation: flush or surface mounting (with surface mounting box
09975…).
Compliance with standardsEMC directive,Standard EN 50428
20514 - Front view and connections
• Button A: used to set a time for the selected operating mode; it is also the con-figuration button.
• Button B: decrease displayed value (temperature or time).• Button C: increase displayed value (temperature or time).• Button D: change operating mode.
TP Bus terminalsA B C D
Fan coil thermostatThe device integrates with the By-me home automation system for temperature control and energy management and is suitable for controlling ambient temperature (heating and air conditioning) by means of 3-speed fan coils.
Main characteristics• adjustment range: - for heating: +5°C - +30°C; - for air conditioning: +10°C - +35°C;• device not compatible with proportional actuators (01466);• temperature differential: adjustable between 0.1°C and 1.0°C;
default value: 0.2°C. The adjustment is made by the control unit.
Compliance with standardsEMC directive,Standard EN 50428
20513 - Display
Protected operation
Roomtemperature
Unit of measurement (Celsius/Fahrenheit)
Timed operation
Nighttime reduction
Heating
Air conditioning
Automatic operation
AntifreezeSystem off
Fan coil speed
Velocità 1
Velocità 2
Velocità 3
Velocità automatica
20513 - Front view and connections
• Button A: cancel operation and configuration button.• Button B: decrease displayed value (temperature or time).• Button C: increase displayed value (temperature or time).• Button D: button for changing the speeds of the fan coil; hold down for 3 seconds to access the menus.
TP Bus terminalsA B C D
Technical datapower supply via Bus 29 Vdcabsorption from Bus 20 mAoperating temperature from -5°C to +40°C (indoor use)
InputsTP bus Bus + -
Technical datapower supply via Bus 29 Vdcabsorption from Bus 20 mAoperating temperature from -5°C to +40°C (indoor use)
InputsTP bus Bus + -
By-me: thermostats and devices for energy management
Room temperature
Measure unit(Celsius/Fahrenheit)
Antifreeze
System OFF
Timer operation(manual, off, nighttime reduction)
Nighttime reductionHeating
Air-conditioning
Automatic operating
Protected operation
Speed 1
Speed 2
Speed 3
Automaticspeed
63
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
49
44,826,5
36
50
49,824,5
36,8
44,8
49
25,5
37,2
26,5
36,7
44,8
49
26
36,8
49,8
50
25,5
37,2
44,8
49
EIKON
EIKON
20514grey
20513grey
20514.NNext
20513.NNext
20514.Bwhite
20513.Bwhite
14514white
14513white
19514grey
19513grey
14514.SLSilver
14513.SLSilver
19514.Bwhite
19513.Bwhite
37,5
26,5 44,7
49
37,5
26,5 44,7
49
16954grey
16953grey
16954.Bwhite
16953.Bwhite
IDEA
IDEA
PLANA
PLANA
ARKÉ
ARKÉ
ThermostatThermostat with display for ambient temperature control - 2 modules
Fan coil thermostatThermostat with display for automatic or manual three-speed fan-coil control - 2 modules
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
64
CLIMA&ENERGY
Electronic active humidity sensorThe device integrates with the By-me home automation system (by means of device 01467 with analog input) for temperature control with the following functions: maintaining humidity below a desired threshold and preventing condensation in underfloor cooling sys-tems. It measures the relative humidity in the room and sends the information via an analog 0-10 V voltage signal or 4-20 mA current signal.
Main characteristics• dual insulation from the power supply grid;• for the maximum measurement precision, install the device at a
height of about 1.5 m above the floor on an internal wall;• do not install in corners of rooms, in alcoves, behind bookshelves
or curtains or near doors, windows, forced air flows or sources of heat;
• max length of connecting cable to receiving device: 100 m. Use 2x0.5mm² twisted cable (art.01840);
• protection class: IP20.
ConfigurationThe output analog signal mode can be selected by means of a dedicated jumper on the rear of the sensor; set it to 0-10 V or to 4-20 mA to obtain the respective output signal mode.
Compliance with standardsEMC Directive, Standard EN 60730-2-13
Bus temperature probeThe device integrates with the By-me home automation system for temperature control in 2 or 4 pipe systems (heating/air conditioning) and neutral zone (only in 4 pipe systems), with a boost function to activate a second source and reach the desired comfort tempera-ture more rapidly.
Main functions• temperature control algorithms: ON/OFF or PID selectable via user
interface:- the ON/OFF algorithm is the control that turns heating off when
the set temperature is exceeded by a given threshold value (the opposite in the case of air conditioning) and turns it back on again when the room temperature returns to below the set tem-perature;
- the PID is an advanced algorithm capable of keeping the temperature of a room stable; it works by turning the system on or off so as to gradually increase or decrease the heating (or cooling) power of the system; ideal for underfloor systems, the algorithm must be suitably calibrated according to the type of room and system;
• use of dedicated By-me actuator to control On/Off type hot/cold valves with actuator 01851.2 and proportional type valves (0-10 V, 4-20 mA) with actuator 01466;
• fan-coil management (3 speed/proportional, On/Off valves);• "boost" function: control of an auxiliary actuator (On/Off, propor-
tional);• functions of external sensor (20432, 19432, 14432, 02965):
- alternative to internal sensor;- average with internal sensor.
Main characteristics• device can be managed remotely (touch screen, web server);
• possibility of connecting an external temperature NTC sensor (20432, 19432, 14432 or 02965): maximum length of sensor connecting cable to the devices: 60 m. Use a twisted cable with a minimum cross-section of 0.5 mm2 (01840);
• device compatible only with control unit 21509 or EasyTool Professional software (01992).
Compliance with standardsLV directive, EMC Directive, Standards EN 50428, EN 50491
Technical datapower supply 12-24 V~ 50 Hz, 12-32 Vdc SELVmaximum power draw at input 1 Wrange of humidity without condensation 10-90 RH%
typical humidity measurement precision in still air at 20°C and 50 RH% ± 3 RH%
operating temperature from -5°C to +45°C (indoor use)viewable range on touch screen supervisors from 10 to 90 RH%
Inputspower supply V+, -
Outputsthermostat RH+, -
Technical datapower supply via Bus 29 Vdcabsorption from Bus 5 mAadjustment range in heating mode from +5°C to +30°Cadjustment range in air conditioning mode from +10°C to +35°Cthermal differential adjustable from control unit 21509 between 0.1°C and 1°Creading accuracy - ≤ ±0.5°C between +15°C and +30°C
- ≤ ±0.8°C at the extremesoperating temperature from 0°C to +40°C (indoor use)
InputsTP bus Bus + -
electronic temperature sensor
Conversion tablevoltage 0-10 V current 4-20 mA
conversion function RH% = Voltage[V] x 10
RH% =(Current[mA]–4) x 6.25
external load limits Minimum 1000Ω Maximum 500Ω
For availability, please contact the sales network
20433 - Front view and connections
RH+
0-10 V 4-20 mA
JumperV+-Terminals:V+: power supply;- : power supply and output reference;RH+: output.
Jumper configuration:
Voltage setting Current setting
20538 - Front view and connections
TP busLED Configuration button
Input for electronic temperature sensor
By-me: thermostats and devices for energy management
65
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
20538.Bwhite
20538grey
20538.NNext
50,3
22,4
49
10,3EIKON
Bus temperature probeTemperature probe for ON/OFF, PWM and PID temperature control (heating and air conditioning), management of 2 and 4 pipe systems, 3 speed and propor-tional fan-coil control, 1 input for wired or flush mounting NTC temperature sensor, for By-me home automation
20433.Bwhite
20433grey
20433.NNext
47,8
44,9
49
10,8EIKON
Electronic active humidity sensorElectronic active humidity sensor, 1 output 0-10 V or 4-20 mA, power supply 12/24 V - 2 modules. Can be integrated with the By-me home automation system via 01467
14538white
14538.SLSilver
50,322,3
49
11,3PLANA
14433white
14433.SLSilver
48,2
44,8
49
12,2PLANA
19538grey
19538.Bwhite
50,5
22,3
49
11ARKÉ
19433grey
19433.Bwhite
48,7
44,8
49
11,7ARKÉ
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
66
CLIMA&ENERGYBy-me: thermostats and devices for energy managementElectronic temperature sensorThe device integrates with the By-me home automation system for temperature and energy management; it is used with control unit 21509 and touch screens 21554, 21511, 21512, 20511.1, 19511 and 14511.1 to display the temperature of the room where the products are installed.
Main characteristics• maximum length of cable connecting sensor to devices: 60 m.
Technical dataresistance 25° 10 KΩviewable temperature on supervisors from -10°C to +70°C
Res
iste
nza
KΩ
0-50
50
100
150
200
250
300
350
400
50 100
NTC_minNTC_nominaleNTC_max
150
Temperatura °C
20432 - Resistance / temperature graph
Wired temperature sensorDevice to be used with thermostat 02950 and time-thermostat 02955 to display the temperature of the room where the product is installed.
Main characteristics• cable length: 4 m.
Technical dataresistance 25° 10 KΩviewable temperature on supervisors from -10°C to +70°C
Res
iste
nza
KΩ
0-50
50
100
150
200
250
300
350
400
50 100
NTC_minNTC_nominaleNTC_max
150
Temperatura °C
02965 - Resistance / temperature graph
Res
ista
nce
kΩ
Temperature °C
nominal
Res
ista
nce
kΩ
Temperature °C
nominal
67
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
20432.Bwhite
14432white
19432grey
20432grey
20432.NNext
14432.SLSilver
19432.Bwhite
22,3
49
24,434,7
34,7
23,4 22,3
49
35,2
24,4 22,2
49
EIKON
PLANA
ARKÉ
Electronic temperature sensorNTC electronic temperature sensor, 1 output
02965
Wired temperature sensor02965 Wired temperature sensor, cable length 4 m
68
CLIMA&ENERGY
KNX standard weather stationThe weather station integrates with the By-me home automation system for temperature control and for managing energy and automation systems. The weather station measures variables such as temperature, wind speed, rainfall and brightness, the values of which can be used for:- viewing on monitors;- activating automation systems in the home automation system on
exceeding the threshold based on limit values.
Main functions• Brightness measurement: this function can be used to turn
exterior lights on at dusk and off at dawn.• Wind measurement: the strength of the wind is measured
electronically, so the measurement is quiet and reliable even in the event of hail, snow and sub-zero temperatures. The weather station is also able to detect whirlwinds and updraughts. This function can also be used to activate awning winding in the case of strong wind or precipitation.
• Rain measurement: the weather station is equipped with a sen-sor with a heated surface so that only rain and snow is measured as precipitation (and not fog or dew). Automatic irrigation can be deactivated in the event of rain. Once it has stopped raining or snowing, the sensor dries quickly and the precipitation message is turned off.
• Temperature measurement: the weather station measures the value of the current temperature.
Main characteristics• configuration button;• CONFIGURATION LED;• protection class: IP44;• dimensions: 96x77x118 mm (L x H x D);• weight: approx. 170 g.
ConfigurationThe weather station functions and parameters are configured via the EasyTool Professional software (01992); the manual and the technical info sheet can be downloaded from the Software->Product Software section of the website www.vimar.com.
Compliance with standardsEMC directive,Standards EN60730-1, EN 50491
Technical dataAUX power supply 12-32 V, 12-24 V~ SELVmax current draw, ripple 10% 100 mAgroup addresses 254 maxpossible associations 255 maxcommunication objects 109rain sensor heating 1.2 Wtemperature measurement range from -40°C to +80°Ctemperature definition 0.1°C
temperature accuracy 1°C from -10°C - +85°C1.5°C from -25°C - +150°C
wind measurement range 0 - 70 m/swind definition <10% of the reading
wind accuracy with an angle of incidence of 45° and mounting on a suitable support
25% from 0 - 15 m/s
brightness measurement range 0 - 150,000 Lux
brightness definition 1 Lux from 0-120 Lux2 Lux from 121-1,046 Lux63 Lux from 1,047-52,363 Lux423 Lux from 52,364-150,000 Lux
brightness accuracy 35%operating temperature from -30°C to +50°C (exterior use)
Inputspower supply +, -Bus TP bus
For availability, please contact the sales network
By-me: thermostats and devices for energy management
AUX12-32 Vdc12-24 Vac
AUX+,-
Bus+,-
Bus +, -
0189
0
01400
L N
01546 - Connections
By-me power supplies:art. 01801, 01400, 01401
69
CLIMA&ENERGY
KNX standard weather station 01546 Weather station, KNX standard, power supply 12-32 Vdc or 12-24 Vac
01546
Installation
Base with straps supplied
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
70
CLIMA&ENERGY
By-me IR interfaceThe device integrates with the By-me home automation system for temperature control. The IR interface can be used to control the air conditioner splitters by learning and emulating the commands of the original remote controls of the controlled devices.It can be associated with the touch screen thermostat 02951, with the touch screen supervisors (21554, 21511, 20511.1, 19511, 14511.1, 21512, 20512, 19512, 16952 and 14512) or with the web server 01945. It can be used to control the splitters directly from the By-me system, either manually or using scenarios and events. The extension lead for the IR control is supplied (length 3 m).
Main characteristics• connector for jack 2.5 mm2;• possibility of programming the group to which it belongs using
the control panel 21509 or from a PC using EasyTool Professional software (01992);
• configuration button; • LED for configuring and indicating IR reception and transmission; • ability to store and replicate 32 commands sent from an infrared
remote control;• 3 m cable with 2.5 mm2 jack and IR transmitter (supplied).
Compliance with standardsEMC directive,Standards EN 50428, EN 50491
Installation of cable with IR transmitter
A: IR sensor of splitterB: adhesive IR transmitter (does not inhibit operation of the remote control)C: cable with IR transmitter to be plugged into jack input. Length 3 m (supplied)
A
C
B
Front view and connections
A: 2.5 mm jack inputB: LEDC: configuration button
A
B C
TP bus
Technical datapower supply via Bus 29 Vdcabsorption from Bus 20 mAinfrared frequency 30 kHz - 60 kHzoperating temperature from -5°C to +45°C (indoor use)
InputsTP bus Bus +, -
By-me: thermostats and devices for energy management
For availability, please contact the sales network
71
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
EIKON
PLANA
ARKÉ
By-me IR interfaceInterface for transmission of By-me commands to IR receiver, for By-me home automation, complete with 3 m cable
50,5
22,5
49
10,5
50,5
22,3
49
11,5
49,7
22,3
49
10,7
20584.1.Bwhite
14584.1white
19584.1grey
20584.1grey
20584.1.NNext
14584.1.SLSilver
19584.1.Bwhite
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
72
CLIMA&ENERGY
01465 - Climate control device for heating systemsThe climate control device for heating systems integrates with the By-me home automation system for temperature control manage-ment. It is suitable for controlling the delivery water temperature. The water temperature may be controlled according to the external ambient temperature or maintained at a constant value. The device features:• 1 output for 3-point mixer valve; • 1 output for circulation pump;• 1 output for proportional mixer valve;• 3 inputs for temperature probes:
- external temperature;- delivery temperature;- optional temperature.
Main functions• connected temperature probe fault alarm signalling;• dew point management in conjunction with humidity sensor
(20433, 19433, 14433): prevents condensation in the case of underfloor cooling;
• circulation pump and mixer valve anti-seize function;• time programming;• screed maximum temperature protection.
Main characteristics• open/close output for controlling 3-point mixer solenoid valves;• On/Off changeover output for circulation pump;• analog output (overload protected) with voltage or current con-
figuration (0-10V/(0)4-20 mA) for controlling proportional solenoid valves;
• 4 output state signalling LEDs;• LED and configuration button;• control of 3 probes PT100, PT1000 and NTC (20432, 19432,
14432, 02965); • reading 2/3 wire configurable temperature probes;• device compatible only with control unit 21509 or EasyTool
Professional software (01992);• installation: on DIN rail (60715 TH35), size 6 modules.
Compliance with standardsLV Directive, EMC Directive,Standards EN 60730-2-9, EN 50491
Technical datapower supply 120-230 V~, 50/60 Hzmains power draw 5 VApower supply from TP Bus 29 Vdc, SELVabsorption from TP Bus 5 mAoperating temperature from -5°C to +45°C (indoor use)
Inputspower supply N, LTP bus +, -
probes T1, T2, T3
Outputs
solenoid valve OUT 1circulation pump OUT 2proportional solenoid valve OUT 3
Controllable loadsOUT 1 resistive loads: 8 A 120-230 V
cosϕ 0.6 motors: 3.5 A 120-230 V
OUT 2 resistive loads: 8 A 120-230 Vcosϕ 0.6 motors: 3.5 A 120-230 V
OUT 3
voltage output: 0-10 V configurableif set in terms of voltage the minimum controllable load is 1000 Ω
current output: (0) 4-20 mA configurableIf set in terms of current the maximum controllable load is 500 Ω
NO ballast regulators for dimmers
For availability, please contact the sales network
01465 - Connections
T2 T3 BUS
OUT 3OUT 2
1 2 3 1 2 3
NC NO C C
CONF.
OUT 3
OUT 2
OUT 1
01465CLIMATIC CONTROLLER120-230 V~ 50/60 HzOUT 1,2 3,5 A 120-230 V~ µOUT 3 0-10 V (0)4-20 mA ε
By-me
+ -
OUT 1
T11 2 3
M
N L
+ -
Power supply 120-230 V~
Solenoidvalve output
Circulation pump output
Proportional solenoid valve output
TP busInputs for PT100, PT1000, NTC probes
01465 - Example of connection
T2 T3 BUS
OUT 3OUT 2
1 2 3 1 2 3
NC NO C C
CONF.
OUT 3
OUT 2
OUT 1
01465CLIMATIC CONTROLLER120-230 V~ 50/60 HzOUT 1,2 16 A 120-230 V~ µOUT 1,2 3,5 A 120-230 V~ µOUT 3 0-10 V (0)4-20 mA ε
By-me
+ -
OUT 1
T11 2 3
M
N L
+ -
Input UnM
SELVY 0 0 +
T1
T2 T3
Power supply 120-230 V~
NTC external probe (02965)
3-wire delivery probe PT100
2-wire optional probe PT1000
TP bus
L N
Mixing solenoid valve
Ope
n
Clo
sed
Circulation pump Proportional
solenoid valve
By-me: thermostats and devices for energy management
73
CLIMA&ENERGY
01465
Climate control device for heating systems 01465 Climate control device for heating systems, supply voltage 120-230 V~ 50/60 Hz, 3 inputs for PT100, PT1000 and NTC probes, 1 mixer valve
control output, 1 output 0-10 V or (0)4-20 mA, 1 8 A 230 V~ change-over relay output, installation on DIN (60715 TH35) rail, occupies 6 modules sized 17.5 mm
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
74
CLIMA&ENERGYBy-me: thermostats and devices for energy management01466 - Actuator with 4 proportional relay outputsThe device functions as a proportional actuator and integrates with the By-me home automation system for managing temperature control, automation and sound systems.It is able to control/adjust the degree of opening of the propor-tional motorised valves or fan-coils that accept variable voltage- or current-controlled signals (e.g. 0-10 V or 4-20 mA). Controls up to 4 valves. The following functions can be performed independently for each output:• controlling proportional motorised valves for current operated
temperature control systems with customisable range (0-20 mA or 4-20 mA);• controlling proportional motorised valves for voltage operated
temperature control systems with customisable range (0-10 V, 1-10V, 0-5 V, 0-1 V, etc.);
• output overload alarm by means of flashing LED (only with voltage control).
Main characteristics• maximum distance between actuator and valve: 10 m with
twisted cable;• protection class IP20;• device compatible only with control unit 21509 or EasyTool
Professional software (01992);• installation on DIN rail (60715 TH35), size 4 modules.
Compliance with standardsLV Directive, EMC Directive,Standards EN 50428, EN 50491
Technical datapower supply 120-230 Vac, 50/60 Hzmains power draw 5 VApower supply from TP Bus 29 Vabsorption from TP Bus 5 mAoperating temperature from -5°C to +45°C (indoor use)
Inputspower supply N, LTP bus +, -
Outputs
solenoid valves OUT 1, OUT 2, OUT 3, OUT 4
Controllable loadsOUT 1 If set in terms of voltage, the minimum controllable
load is 1000 Ω
If set in terms of current, the maximum controllable load is 500 Ω
OUT 2
OUT 3
OUT 4
01466ANALOGACTUATOR
By-me
+ - + - + - + - OUT 1 OUT 2 OUT 3 OUT 4
OUT 1
OUT 2
OUT 3
OUT 4
120-230 V~ 50/60 Hz OUT 0-10 V (0)4-20 mA ε
VA
N L
Input Un
Y 0 0 +
Input Un
Y 0 0 +
Input Un
Y 0 0 +
Input Un
K K K K
Y 0 0 +
01466 - Example of connection
Power supply120-230 V~
24 Vac SELVart.16887
4 motorised proportional valves
TP bus
01466 - Connections
01466ANALOGACTUATOR
By-me
+ - + - + - + - OUT 1 OUT 2 OUT 3 OUT 4
OUT 1
OUT 2
OUT 3
OUT 4
120-230 V~ 50/60 Hz OUT 0-10 V (0)4-20 mA ε
VA
N L
TP bus
Proportional analog outputs(0)4-20 mA or 0-10 V
Power supply120-230 V~
75
CLIMA&ENERGYBy-me: thermostats and devices for energy management
01466
Actuator with 4 proportional relay outputs 01466 Actuator with 4 (0)4-20 mA or 0-10 V proportional analogue outputs with re-scalable maximum output voltage or current, supply voltage
120-230 V~ 50/60 Hz, By-me home automation, installation on DIN (60715 TH35) rail, occupies 4 modules sized 17.5 mm
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
76
CLIMA&ENERGY
01467 - Device with 3 analog signal inputsThe device with analog signal inputs integrates with the By-me home automation system for temperature and energy manage-ment; the device has 3 analog inputs: 1 input for 0-10V voltage or 0-20mA current sensor, 1 input for NTC wired or flush mounting temperature sensor and 1 input for brightness sensor (01530).The brightness sensor allows for energy savings because it enables artificial light to be balanced with natural light to achieve the desired brightness level.
Main functionsThe device can perform the following functions:with temperature sensor input:• send temperature measurement to the Bus;• block temperature sensor input;with voltage or current sensor input:• send measured value to the Bus;• ON or OFF command for a load on exceeding a settable level;• voltage or current sensor input block;with brightness sensor input:• maintain a constant set brightness level in a room (this mode is
available only if a dimmer is also present in the same group);• block brightness sensor input.
Main characteristics• input for temperature sensors 20432, 19432, 14432 and 02965;• input for brightness sensor 01530;• input for current or voltage sensor;• device compatible only with control unit 21509 or EasyTool
Professional software (01992);• maximum length of sensor cables:
- brightness sensor (01530): 100 m;- electronic temperature sensor (20432, 19432, 14432): 60 m;- current/voltage sensor (20433, 19433, 14433): 100 m;
• all the sensors must be connected to SELV devices:• installation: on DIN rail (60715 TH35), size 2 modules.
Technical datapower supply from TP Bus 29 Vdcabsorption from TP Bus 20 mAvoltage input resistance 66 kΩcurrent input resistance 200 Ωoperating temperature from -5°C to +45°C (indoor use)
InputsTP bus +, -current or voltage sensor 0-10 V or 0-20 mAtemperature sensor NTCbrightness sensor 01530
For availability, please contact the sales network
01467 - Connections
01467
CONF.
BUS
INPUTS
ANALOG
V
A
0-10V
(0)4-20 mA
TP Bus terminals
Temperature sensorBrightness sensor (01530)
Sensor0-10 V or 0-20 mA
By-me: thermostats and devices for energy management
Compliance with standardsEMC directive,Standards EN 50428, EN 50491
77
CLIMA&ENERGY
01467
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
Device with 3 analog signal inputs 01467 Device with 3 analog signal inputs, 1 0-10 V or 4-20 mA input, 1 input for wired or flush mounting NTC temperature sensor, 1 input for brightness
sensor 01530, for By-me home automation, installation on DIN (60715 TH35) rail, occupies 2 modules sized 17.5 mm
78
CLIMA&ENERGY
Actuator with relay output 16 A 230 V ~ with current sensorThe actuator integrates with the By-me home automation system for temperature and energy control.The device performs the function of an actuator and measures power and calculates energy consumption. It also creates a log of the energy values and allows for load malfunction alarm signals.The device can be used in automation, energy saving and climate control systems.
Main functions• measuring the power absorbed by the load;• monostable/bistable relay behaviour;• delay in activation, deactivation and duration;• load fault alarm with fault detection power threshold;• scenario control;• log of energy values.
Main characteristics• controllable loads at 230 V ~ (NO contact):
- resistive loads: 16 A (20,000 cycles);- incandescent lamps: 8 A (20,000 cycles);- fluorescent lamps and energy saving lamps: 1 A (20,000 cycles);- electronic transformers: 4 A (20,000 cycles);- ferromagnetic transformers: 10 A (20,000 cycles);- cosϕ 0.6 motors: 3.5 A (100,000 cycles);
• protection class IP20;• overvoltage category: III;• measurement category: III.
Compliance with standardsLV directive,Standards EN 61010-1, EN 61010-2-030,EMC directive,Standards EN 61000-6-1, EN 61000-6-3
20537 - Front view and connections
A: configuration LEDB: configuration buttonC: TP Bus terminals
A B C
Technical datamains power supply 230 V~ dc, 50 Hzpower supply via Bus 29 Vdcabsorption from Bus 5 mAoperating temperature from -5°C to +40°C (indoor use)
InputsTP bus Bus + -230 V~ 50 Hz L, 1, N
By-me: thermostats and devices for energy management
79
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
46,5
37 44,8
49
36
46,5
44,8
49
EIKON
20537grey
20537.NNext
20537.Bwhite
14537white
19537grey
14537.SLSilver
19537.Bwhite
46,9
36,7 44,8
49
PLANA
ARKÉ
Actuator with 16 A 230 V ~ relay output and current sensor Actuator with 6 A 230 V ~ 50 Hz relay output 1 and built-in current sensor - 2 modules
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
80
CLIMA&ENERGY
01452 - Pulse counter interfaceThe pulse counter interface integrates with the By-me home auto-mation system for temperature and energy control.The device enables the pulses transmitted by a fiscal meter or counter for gas, water, hot water, electricity, wind speed, etc. to be counted and puts the data collected onto the By-me bus. The pulse is reproduced on the output for other similar devices.
Main characteristics• parameters: - minimum pulse duration; - conversion parameters; - setting for measured variable; - setting for initial meter value;• flush-mounting installation;• configuration by means of By-me control unit (21509) or
EasyTool Professional application (01992);• device compatible only with control unit 21509 or EasyTool
Professional software;• protection class IP20;• overvoltage category: III;• measurement category: III.
Compliance with standardsEMC directive,Standards EN 61010-1, EN 61010-2-030, EN 61000-6-1,EN 61000-6-3
01452 - Front view and connections
A: configuration buttonB: Configuration LEDC: TP bus terminals
A
B
C
Technical datapower supply via Bus 29 Vdcabsorption from Bus 10 mAoperating temperature from -5°C to +40°C (indoor use)
InputsTP bus Bus +, -IN (pulse input) +, -
OutputsOUT (pulse reproduction) +, -
01451 - Power meter with current sensorThe power meter integrates with the By-me home automation sys-tem for temperature and energy control.The device measures the consumption of a load supplied by the electrical line. The consumption data such as power and energy dissipation are displayed on the touch screens (21553, 21554, 21511, etc.) connected to the By-me bus.
Main characteristics• measurable powers up to 3680 W;• configuration by means of By-me control unit or EasyTool
Professional application (01992);• flush-mounting installation;• protection class IP20;• overvoltage category: III;• measurement category: III.
Compliance with standardsLV directive, Standards EN 61010-1, EN 61010-2-030EMC directive, Standards EN 61000-6-1, EN 61000-6-3
01451 - Front view and connections
A: configuration buttonB: configuration LEDC: TP bus terminals
A
B
C
Technical datamains power supply 120-230 V~, 50/60 Hzrated current 16 Apower supply via Bus 29 Vdcabsorption from Bus 5 mAoperating temperature from -5°C to +40°C (indoor use)
InputsTP bus Bus + -120-230 V~ 50/60 Hz 1, L, N
By-me: thermostats and devices for energy management
81
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
26 50,6
51,5
01452
26 50,6
51,5
01451
Power meter with current sensor01451 Power meter with built-in current sensor, detectable power up to 3680 W, flush mounting
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
Pulse counter interface01452 Pulse counter interface for detecting data from devices equipped with pulse output such as electricity, water and gas meters, with flush mounting
82
CLIMA&ENERGY
Power meter with 3 inputs for current sensor for DIN rail (60715 TH35)The power meter integrates with the By-me home automation sys-tem for temperature and energy control.The device measures the power on one or more mains lines. It can work on both single and three phase systems and can monitor up to 3 electrical lines independently.The current on the electrical line to be monitored is measured with a current probe (01457, 01458); it creates a log of the energy values of each of the lines.
Main characteristics• measurable powers: from 25 W to 100 kW (up to 33 kW per line);• it measures active power on a maximum of 3 lines (L1, L2 and L3);• inputs for current sensors (01457, 01458); • configuration by means of By-me control unit (21509) or
EasyTool Professional application (01992);• protection class: IP20;• overvoltage category: III;• measurement category: III;• installation on DIN rail (60715 TH35): 1 module size 17.5 mm.
Compliance with standardsLV directive, Standards EN 61010-1, EN 61010-2-030EMC directive, Standards EN 61000-6-1, EN 61000-6-3
01450ENERGYMETER
CONF. Configuration button
Inputs for current sensor
Terminals for line connection
TP bus terminals
Input cable at terminals S of the power meter
Toroidal current sensor
01450 - Front view and connections
Current sensor 01457, 01458
01455LOADS
CONTROL
CONF.
Inputs for current sensor
Terminals for line connection
Configurationbutton
TP bus terminals
Input cable at terminals S of the power meter
Toroidal current sensor
01455 - Front view and connections
Current sensor 01457, 01458
Load control module, 3 inputs for toroidal current sensor for DIN rail (60715 TH35)The load control module integrates with the By-me home auto-mation system for temperature and energy control.The device prevents the switch in the electricity meter from trip-ping due to overload; it can operate on both single-phase and three-phase systems. The current on the electrical line to be monitored is measured with a current probe (01457, 01458) and it is capable of controlling up to 3 electrical lines independently. IT is designed to control systems in which a generating plant is also present (e.g. photovoltaic systems). If the line cable is not easily accessible, the measurement can be made remotely by means of the power meter 01450 connected to the By-me bus. It saves the log of the energy values of each line.
Main characteristics• measurable powers: 25 W - 100 kW (up to 33 kW for each line);• measures the active power on a maximum of 3 local lines and
3 remote lines;• inputs for current sensors (01457, 01458); • configuration by means of By-me control unit (21509) or
EasyTool Professional application (01992);• protection class: IP20;• overvoltage category: III;• measurement category: III;• installation on DIN rail (60715 TH35): 1 module size 17.5 mm.
Compliance with standardsLV directive, Standards EN 61010-1, EN 61010-2-030EMC directive, Standards EN 61000-6-1, EN 61000-6-3
Technical datapower supply via Bus 29 Vdcabsorption from Bus 5 mApower supply L1-N 120-230 V, 50/60 Hz
power supply L1-L2-L3-N 127-200 V, 50/60 Hz230-400 V, 50/60 Hz
operating temperature from -5°C to +40°C (indoor use)InputsTP bus Bus +, -three-phase power supply L1, L2, L3, Ncurrent sensors (01457, 01458) S1, S2, S3
Technical datapower supply via Bus 29 Vdcabsorption from Bus 5 mApower supply L1-N 120-230 V, 50/60 Hz
power supply L1-L2-L3-N 127-200 V, 50/60 Hz230-400 V, 50/60 Hz
operating temperature from -5°C to +40°C (indoor use)InputsTP bus Bus +, -three-phase power supply L1, L2, L3, Ncurrent sensors (01457, 01458) S1, S2, S3
By-me: thermostats and devices for energy management
83
CLIMA&ENERGY
Power meter with current sensor for DIN (60715 TH35) rail
01450Power meter, 3 inputs for toroidal current sensor, 25 W-100 kW detectable power, single-phase supply voltage 120-230 V 50/60 Hz three-phase 230/400 V 50/60 Hz, installation on DIN (60715 TH35) rail, occupies 1 module sized 17.5 mm. Supplied with a toroidal current sensor 01457
Load control module, 3 inputs for toroidal current sensor for DIN (60715 TH35) rail
01455Load control module, 3 inputs for toroidal current sensor, 25 W-100 kW detectable power, single-phase supply voltage 120-230 V 50/60 Hz three-phase 230/400 V 50/60 Hz, installation on DIN (60715 TH35) rail, occupies 1 module sized 17.5 mm. Supplied with a toroidal current sensor 01457
Toroidal current sensor01457 Toroidal current sensor for load control and power meter, hole diameter 7.5 mm, cable length 40 cm
0145001457
01457
01457
01455
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
84
CLIMA&ENERGY
Actuator with 16 A 120-230 V~ relay output and built-in current sensorThe actuator integrates with the By-me home automation system for temperature and energy control.The device performs the function of an actuator and measures power and calculates energy consumption. It also creates a log of the energy values and enables alarm signalling due to malfunction-ing such as current leakage and load faults.The device can be used in automation, energy saving and climate control systems.
Main characteristics• controllable loads at 120 - 230 V~ (NO contact):
- resistive loads: 16 A (20,000 cycles);- incandescent lamps: 8 A (20,000 cycles);- fluorescent lamps and energy saving lamps: 1 A (20,000 cycles);- electronic transformers: 4 A (20,000 cycles);- ferromagnetic transformers: 10 A (20,000 cycles);- cosϕ 0.6 motors: 3.5 A (100,000 cycles);
• configuration by means of By-me control unit (21509) or EasyTool Professional application (01992);
• protection class IP20;• overvoltage category: III;• measurement category: III;• installation on DIN rail (60715 TH35): 1 module size 17.5 mm.
Compliance with standardsLV directive, standards EN 61010-1, EN 61010-2-030,EMC directive, Standards EN 61000-6-1, EN 61000-6-3
01456ENERGYMETER
CONF.
Inputs for current sensor
Terminals for line connection
TP bus terminals
Input cable to actuator terminals Toroidal residual current sensor
01456 - Front view and connections
Optional current sensor 01459
Technical datapower supply via Bus 29 Vdcabsorption from Bus 5 mApower supply L1-N 120-230 V, 50/60 Hzoperating temperature from -5°C to +40°C (indoor use)
InputsTP bus Bus +, -power supply L, Ncurrent sensors (01459) Sensor
By-me: thermostats and devices for energy management
Configurationbutton
85
CLIMA&ENERGY
Actuator with 16 A 120-230 V~ relay output and built-in current sensor01456 Actuator with 16 A 120-230 V~ 50/60 Hz relay output and built-in current sensor, 1 input channel for toroidal residual current sensor,
DIN (60715 TH35) rail installation, occupies 1 module size 17.5 mm. Supplied without toroidal residual current sensor.
Toroidal current sensor, hole ø 19 mm01458 Toroidal current sensor for load control and power meter, hole diameter 19 mm, 40 cm cable length
Toroidal residual current sensor, hole ø 9 mm01459 Toroidal residual current sensor for power actuator, hole diameter 9 mm, 40 cm cable length
01456
01458
01459
By-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
86
CLIMA&ENERGYBy-me: thermostats and devices for energy management01850.2 - Actuator with 1 relay output
Main characteristics• changeover relay output;• controllable loads at 120 - 230 V~:
- resistive loads: 16 A (20,000 cycles);- 12-24 Vdc max 1 A loads;- incandescent lamps: 10 A (20,000 cycles);- fluorescent lamps and energy saving lamps: 1 A (20,000 cycles);- electronic transformers: 4 A (20,000 cycles);- ferromagnetic transformers: 10 A (20,000 cycles);- cos ø 0.6 motors: 3.5 A (100,000 cycles);
• removable terminal covers;• removable Bus terminal;• removable cover and spacer for installation on conduits, ceilings
and false ceilings;• screw seats for surface mounting;• local control buttons with LED backlighting;• installation on DIN rail (60715 TH35): 2 modules size 17.5 mm.
Operation• monostable and bistable relay;The actuator 01850.2 can also be used as a relay for the pump or
for the circulation valve in a multi-zone heating or 2 or 4-pipe air conditioning system.
Important: to control large loads (electrical appliances, groups of lamps, etc.) an actuator 01456 or a support contactor must be installed.
Compliance with standardsLV directive, EMC Directive, Standard EN 50428
pulsanteper modalitàmanuale
LED e pulsanteattuazione relé
LED e pulsantedi configurazione
linea BUS
NO NCC
01850.2 - Front view and connections
01851.2 - Actuator with 4 relay outputs
Main characteristics• changeover relay outputs;• controllable loads at 120 - 230 V~:
- resistive loads: 16 A (20,000 cycles);- 12-24 Vdc max 1 A loads; - incandescent lamps: 10 A (20,000 cycles);- fluorescent lamps and energy saving lamps: 1 A (20,000 cycles);- electronic transformers: 4 A (20,000 cycles);- ferromagnetic transformers: 6 A (20,000 cycles);- cos ø 0.6 motors: 3.5 A (100,000 cycles);
• removable terminal covers;• removable Bus terminal;• screw seats for surface mounting;• local control buttons with LED backlighting;• installation on DIN rail (60715 TH35): 4 modules size 17.5 mm.
Operation• monostable and bistable relay;• actuator 01851.2 can be used as a 4 relay output device to con-
trol a motor (e.g. a fan-coil) in conjunction with a circulation valve, as a generic 4-output actuator or as an actuator for heating sys-tems (fan coil and circulation valve control or in conjunction with 01850.2)
Important: to control large loads (electrical appliances, groups of lamps, etc.) an actuator 01456 or a support contactor must be installed.
Compliance with standardsLV directive, EMC Directive, Standard EN 50428
A B C D E F
linea BUS
CNC
NO
relè 1
CNCNO
relè 4
CNC
NO
relè 2CNC
NO
relè 3
NC NO C NC NO C NC NO COUT 1 OUT 2 OUT 3
OUT 1
OUT 2
OUT 3
OUT 4
SWITCHACTUATOR
01851.2
NC NO C NC NO C NC NO COUT 1 OUT 2 OUT 3
OUT 1
OUT 2
OUT 3
OUT 4
SWITCHACTUATOR
01851.2
CNO CNONCCNONC
M
V2
V3V1
CN L
~
NO C
NL
~
A: LED and button to actuate relay 1; B: LED and button to actuate relay 2;C: LED and button to actuate relay 3;
D: LED and button to actuate relay 4; E: LED and configuration button; F: manual mode button.
01851.2 - Front view and connections
Technical datapower supply via Bus 29 Vdcabsorption from Bus 14 mAdissipated power 1.5 Wheat loss with cable Ø 4 mm2 1.5 W at 16 Aoperating temperature from -5°C to +45°C (indoor use)
InputsTP bus Bus +, -
OutputsOUT NO, C, NC
Technical datapower supply via Bus 29 Vdcabsorption from Bus 18 mAdissipated power 6.5 Wheat loss with cable Ø 4 mm2 1.5 W at 16 Aoperating temperature from -5°C to +45°C (indoor use)
InputsTP bus Bus +, -
OutputsOUT 1, 2, 3, 4 NC, NO, C
LED and button forrelay actuator
LED and configurationbutton
button formanual mode
line BUS
87
CLIMA&ENERGYBy-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
01851.2
01850.2
1 relay output actuator01850.2 Lowered actuator with 16 A 120-230 V~ change-over relay output, button for local control, complete with removable spacer for installation on DIN
(60715 TH35) rail, occupies 2 modules sized 17.5 mm
4 relay output actuator01851.2 Actuator with 4 16 A 120-230 V~ change-over relay outputs, buttons for local control, installation on DIN (60715 TH35) rail, occupies 4 modules
sized 17.5 mm
88
CLIMA&ENERGYBy-me: thermostats and devices for energy management01400 - Power supply unitThe power unit supplies the 29 Vdc voltage needed to power By-me devices. The maximum output current is 400 mA. A maxi-mum of 2 power units can be installed on a line with a minimum distance of 40 m of Bus cable.
Main characteristics• auxiliary output to supply other devices (for example touch
screens);• installation on DIN rail (60715 TH35): 2 modules size 17.5 mm.
Compliance with standardsLV Directive, EMC Directive,Standards EN 60065, EN 61000-6-3, EN 50130-4, EN 50491
01401 - Power supplyfor DIN rail (60715 TH35)The power unit supplies the 29 Vdc voltage need-ed to power By-me devices. The maximum output current is 1280 mA. A maximum of 2 power units can be installed on a line with a minimum distance of 40 m of Bus cable.
Main characteristics• auxiliary output to supply other devices (for example touch
screens);• installation on DIN rail (60715 TH35): 8 modules size 17.5 mm.
Compliance with standardsLV Directive, EMC Directive,Standards EN 60065, EN 61000-6-3, EN 50130-4, EN 50491
01400
01400 - Front view and connections
Indicator LED
TP busAUX29 V 29 V
230 V~
01401
1280
01401 - Front view and connections
mains voltage
output overvoltage
overload
TP busAUX29 V 29 V
120-230 V~
Technical datapower supply 230 V~ 50/60 Hzcurrent draw 150 mABus output voltage with decoupling coil 29 VdcAUX output voltage 29 Vdcmax output load 400 mA (IBUS + IAUX)dissipated power 4 Woperating temperature from -5°C to +45°C (indoor use)
Inputspower supply 230 V~ L, NTP bus Bus +, -
Output29 Vdc AUX +, -
Technical datapower supply 120-230 V~ 50/60 Hz
current draw 580 mA @ 120 V~370 mA @ 230 V~
bus output voltage with decoupling coil 29 VdcAUX output voltage 29 Vdcmax output load 1280 mA (IBUS + IAUX)dissipated power 7.5 Woperating temperature from -5°C to +45°C (indoor use)
Inputspower supply 230 V~ L, NTP bus Bus +, -
Output29 Vdc AUX +, -
For availability, please contact the sales network
89
CLIMA&ENERGYBy-me: thermostats and devices for energy management
01400
01401
Power supply unit01400 Power unit with 29 Vdc 400 mA output, supply voltage 230 V~ 50/60 Hz, with decoupling coil, installation on DIN (60715 TH35) rail, occupies
2 modules sized 17.5 mm
Power supply unit 01401 Power supply unit with 29 Vdc 1280 mA output, supply voltage 120-230 V~ 50/60 Hz, with decoupling coil, installation on DIN (60715 TH35) rail,
occupies 8 modules sized 17.5 mm
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
90
CLIMA&ENERGYBy-me: thermostats and devices for energy management
Compliance with standardsLV Directive, EMC Directive,Standards EN 50428, EN 50491
01468 - Logic unitThe logic unit allows adjustment and control functions (logics) to be performed within the By-me system. These logics are defined using the EasyTool Professional software and then transferred to the device via USB to become operative. The device is equipped with an OTG type micro USB port used in "device" mode for connection to the PC, which is required to download configuration files. For the detailed list of usable logics, functional blocks of various kinds (delays, mathematical functions, calendars, etc.) and By-me blocks available for configuring the logic unit, refer to the EasyTool Professional manual.
Main functionsThe device allows complex logics to be defined in the By-me system using the EasyTool Professional interface for logic unit configuration. With this interface it is possible to:• create various relationships between various By-me system
blocks by means of logic gates, delay blocks and mathematical functions;
• save and manage scenarios;• plan calendar events (time programmes), with various frequencies,
durations, validity periods, etc. To be able to perform this kind of function, the device requires the presence of the system clock provided by the control unit 21509 or by web server 01945.
Main characteristics• LED and configuration button;• connection to laptop PC by means of a cable with connector
USB micro-B on the card side and USB type A on the PC side: to guarantee conformity with standards the connected PC must be battery (not mains) powered;
• device compatible only with control unit 21509 or EasyTool Professional software (01992);
• protection class IP20;• installation on DIN rail (60715 TH35): 1 module size 17.5 mm.
Technical datapower supply via Bus 29 Vdcabsorption from Bus 25 mAdissipated power < 1 Woperating temperature from 0°C to 45°C (indoor use)
InputsTP bus Bus +, -USB micro-B
01468 - Front view and connections
01468
CONF.
TP bus
USB micro connector
Configuration button and LED
91
CLIMA&ENERGYBy-me: thermostats and devices for energy management
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
Logic unit01468 Unit for implementing logic, mathematical, timing and messaging functions, installation on DIN (60715 TH35) rail, for By-me home automation,
configurable only with EasyTool Professional, occupies 1 module sized 17.5 mm
01468
92
CLIMA&ENERGYBy-me: thermostats and devices for energy management3-module control unitThe control unit is the device that programs operation of the entire By-me system; as an alternative the By-me system can be programmed from PC using EasyTool Professional software. The control unit is necessary for management of climate control, events, and intrusion detection system, whereas all the other sys-tem functions can be configured using solely the software EasyTool Professional.The system can be configured easily and intuitively from the inno-vative touch screen with no keys, from the definition of individual devices to programming all functions, including: scenes, automated tasks, sound distribution, load control, intrusion detection and access control.The diagnostics function provides a rapid analysis of the operation of all the system devices, while the events memory function enables all the operations performed by the system to be viewed (switching on and off, intrusion detection alarms and technical alarms, etc.). The device allows you to connect an external temperature sensor (art. 20432, 14432) to view the climate in the area in which the sensor is installed (maximum length of cable connecting sensor to devices: 60 m). The centralized controller does not require an auxiliary power supply for the display.
Main characteristics• with external temperature sensor (20432, 14432); use a twisted
cable with minimum cross-section of 0.5 mm2 (01840);• flush mounted or mounted on DIN rail (60715 TH35) via the sup-
port provided V51923.
OperationTouching the menus on the main screen gives access to all sub-menus and parameters enabling you to:• manage the ambient temperature, dividing the system into up to
40 areas controlled by 40 separate programs;• centralize and automate functions (up to 32 scenarios and 16
programs);• manage the intrusion-detection system;• control and command functions/applications;• control loads and energy consumption;• manage the sound system.
Compliance with standardsEMC directive,Standards EN 50428, EN50491
temperature sensor terminals
PIN-STRIP connector for connecting to interface 01991
TP Bus terminals
display
21509 - Front view and connections
Setup Menu Configuration Menu Groups / Automation Groups Menu
Automated Task Groups / Stair Light Menu
Example of control unit menu
Tap
Press
Flick
Drag oriz
Drag vert
Tap
Press
Flick
Drag oriz
Drag vert
Tap
Press
Flick
Drag oriz
Drag vert
Tap
Press
Flick
Drag oriz
Drag vert
Technical datapower supply via Bus 29 Vdcabsorption from Bus 45 mAabsorption from Bus on stand-by (without backlighting) 25 mAaudio/video module absorption 120 mAoperating temperature from -5°C to +40°C (indoor use)
InputsTP bus Bus + -
external temperature sensor (20432, 19432, 14432)
connection to interface 01991 PIN-STRIP connector
93
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
By-me: thermostats and devices for energy management3-module control unitControl and configuration unit, monochrome touch screen, 1 input for temperature sensor, supplied with V51923 support for installation on DIN (60715 TH35) rail - 3 modules. Complete with RJ45 connector for front-panel programming, cable and V51921 support for installation on DIN (60715 TH35) rail
Support for DIN rail (60715 TH35)V51921 1 module support for installation of Eikon, Arké and Plana appliances on DIN (60715 TH35) rail, occupies 1.5 modules sized 17.5 mm, RAL
grey 7035. Supplied with protective diaphragm
V51923 3 module support for installation of Eikon Evo, Arké and Plana appliances on DIN (60715 TH35) rail, occupies 4 modules sized 17.5 mm, RAL grey 7035. Supplied with protective diaphragm
21509grey
V51923V51921
21509.NNext
21509.Bwhite
67,3
49
37
46,5EIKON
57
75,5
71,6
Example of installation on DIN rail with front programming connector.
Example of use of supplied stylus for control unit navigation.
Stylus supplied
Delivered with control unit Delivered with control unit
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
94
CLIMA&ENERGYBy-me: thermostats and devices for energy management01992 - EasyTool Professional SuiteThe package contains the suite of all Vimar appliances that serve for the complete design of any system. The interface, equipped with a USB driver, must be connected to a personal computer on which the application suite must be installed. The suite consists of the following software:• EasyTool Professional configuration, programming and com-
plete maintenance of the By-me system via the PC. With this software you can completely manage all the By-me control units 01950, 01956, 01960, 21509 and the web server 01945.
• EasyDraw and EasyCap for design of systems in CAD style, integrating both the range of By-me devices and that of KNX devices. The application integrates with EasyTool Professional 2.1 by means of the Import/Export function and allows for off-line design of all By-me automation devices. IT is also possible to inte-grate with ETS4 software by means of the Import/Export function to design the topological infrastructure of the KNX system.
Main characteristics• power supply directly from PC via USB port;• USB cable with type A connector for PC connection, length 1.8
metres (supplied);• customised and polarised cable with RJ11 connector for special
socket connection, length 2 metres (supplied);• USB interface operating temperature: + 5 - +40°C;• USB interface dimensions: 115x75x25 mm.
OperationThe USB LED comes on when the interface is connected to the PC. During data transmission/reception, the BUS LED flashes.
Compliance with standardsEMC directive,Standards EN 55022, EN 55024
Requirements for Suite installation systemPC processor Pentium 4 or higher
RAM 2 GB (recommended)
monitor resolution 1024 x 768 pixel
free space on hard disk 1 GB
operating system Windows 2000®, Windows XP®, Windows Vista®, Windows 7®, Windows 8®
Can be installed on 32 bit or 64 bit systems
01840 - Bus cable
Main characteristics• cross-section 2x0.5 mm2;• operating voltage U0/U = 300/500 V according to HD 21.1;• nominal voltage towards earth U0 = 400 V according to CEI UNEL 36762;
• resistance (20°C): 39 Ω / km;• halogen free;• operating temperature: -15°C - +70°C.
95
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
By-me: thermostats and devices for energy managementEasyTool Professional Suite01992 Software suite containing EasyTool Professional for the By-me system complete with an interface for the BUS connection and a special RJ11 jack
to a PC via a USB port, EasyDraw and EasyCap software for designing and quoting electrical systems
Special RJ11 socket for BusSpecial RJ11 socket for Bus, screw terminals
EIKON
IDEA
PLANA
ARKÉ
22,3
49
33,6
43,1
22,3
49
33,6
43,1
22,3
49
32,6
43,1
24,8
50
33,2
43,2
20329grey
20329.NNext
20329.Bwhite
14329white
19329grey
14329.SLSilver
19329.Bwhite
16339grey
16339.Bwhite
01992Hardware key supplied. Required for use of software.
Accessories for Bus system01839 Removable 2 pole screw terminal for Bus circuit
01840 Cable for Bus systems, halogen-free 2x0.50 mm2, rated voltage towards earth 400 V, suitable for installation with I Category power cables, white – 100 m
0184001839
BY-
ME
THE
RM
OS
TATS
AN
D D
EVI
CE
S
96
CLIMA&ENERGYWell-contact Plus : thermostats for energy management Electronic thermostat KNXDevice for ambient temperature control (heating/air conditioning) in 2 or 4 pipe systems (heating/air conditioning) and neutral zone (only in 4 pipe systems), with "boost" function to activate a second source and reach the desired comfort temperature more rapidly; it can interact with other thermostats and with a supervision unit (PC with Well-contact Suite software). It is able to manage 2 climatic zones entirely independently (equivalent to two thermostats A and B). The heating/air conditioning modes are managed for each zone according to the corresponding reference temperature. It is equipped with an NC or NO programmable relay that can be used for generic applications (e.g. switching on light, closing zone sole-noid valve, activating electric towel heater, etc.) or to control speed 1 of the fan coil managed by thermostat A or thermostat B. It also has an NC or NO programmable digital input that can be used for applications such as detecting an open window. The thermostat is equipped with an RGB display and 6 capacitative buttons to control temperature set point, fan coil speed, configuration of the
thermostat operating modes and display colour. Main characteristics• RGB backlit touch screen display with configurable colours;• relay output NO 24 V~ SELV 4 A;• possibility of connecting an external temperature NTC sensor
(20432, 19432, 14432 or 02965): maximum length of sensor connecting cable to the devices: 60 m. Use a twisted cable with a minimum cross-section of 0.5 mm2 (01840);
• possibility of using the temperature values measured by 8 different probes connected to the KNX Bus (DPT_Value_Temp type data)
• room humidity display;• digital input for NO or NC contact (voltage free, SELV);• the max distance between the input contact and the thermostat
is 30 m;• main functions:
- adjusting temperature set point of the room (within the limits set by reception);
- adjusting the fan coil speed;• this device contains only SELV circuits that must be kept sepa-
rate from circuits with dangerous voltage.
ConfigurationThe thermostat and its physical address, parameters, operation, etc. are all configured using the ETS software. If the thermostat is loaded with an incorrect ETS application, the red LED on the back of the device will flash and all the LCD segments will blink on the display (“device type” error). To restore the desired configuration, load the device with the correct ETS application. The user, by
means of the front buttons, will be able to change the temperature set point and the speed of the fan-coil; changing these param-eters forces the thermostat onto manual operation. With ETS it is possible to set the following parameters (directly from the graphic windows):• general settings; • temperature sensor;• temperature setpoint;• setpoint temperature;• input and output;• adjustment;• valve;• fan coil speed;• scenarios.
Compliance with standardsEMC directive, Standard EN 50428, EN 50491
Technical datapower supply from KNX Bus 29 Vdcabsorption from KNX Bus 20 mA
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
operating temperature from 0°C to +40°C (indoor use)InputsKNX TP Bus EIB + -programmable digital input 1, 2
external temperature sensor(20432, 19432, 14432, 02965)
Outputs
relay NO 24 V~ SELV 4 A cosϕ 1; 24 V~ SELV 2 A cosϕ 0.6 NO, C
Temperature sensorDevice for use with centralized controller 21509 and touch screens 21554, 21511, 21512, 20511.1, 19511 and 14511.1 to detect the ambient temperature where the products are installed.
Main characteristics• maximum length of cable connecting sensor to devices: 60 m.
Res
iste
nza
KΩ
0-50
50
100
150
200
250
300
350
400
50 100
NTC_minNTC_nominaleNTC_max
150
Temperatura °C
20432 - Resistance / temperature graph
Technical dataresistance 25° 10 KΩviewable temperature on supervisors from -10°C to +70°C
02952 - Front view and connections
Configuration button
Input
Common input
CRelay
NO
KNX bus line
LED
External temperature sensor terminals
Room temperature
Heating
Operation setup button
Fan coil setting button
Up / increase button
Down / decrease button
Room humidity
Fan-coil speed
For availability, please contact the sales network
Res
ista
nce
kΩ
Temperature °C
nominal
97
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
Well-contact Plus : thermostats for energy management
49
44,826,5
36EIKONARKÉPLANA
02952.Bwhite
02952black
Electronic thermostat KNXElectronic touch screen thermostat for room temperature control (heating and air conditioning) of 2 independent zones, KNX standard, 1 NO 4 A 24 V~ relay output, 1 input for electronic temperature sensor or wired temperature sensor, 1 programmable digital input, LED RGB backlighting, to be completed with Eikon, Arké or Plana cover plates - 2 modules
20432.Bwhite
14432white
19432grey
20432grey
20432.NNext
14432.SLSilver
19432.Bwhite
22,3
49
24,434,7
34,7
23,4 22,3
49
35,2
24,4 22,2
49
EIKON
PLANA
ARKÉ
Temperature sensorNTC electronic temperature sensor, 1 output
WE
LL-C
ON
TAC
T P
LUS
THE
RM
OS
TATS
AN
D D
EVI
CE
S
98
CLIMA&ENERGY
Electronic thermostatDevice for ambient temperature control (heating/air conditioning), can interact with the other thermostats and with a supervision cen-tre (PC with Well-contact Suite software). It is able to manage 2 cli-matic zones entirely independently (equivalent to two thermostats A and B). The heating/air conditioning modes are managed for each zone according to the corresponding reference temperature. It is equipped with an NC or NO programmable relay that can be used for generic applications (e.g. switching on light, closing zone solenoid valve, activating electric towel heater, etc.) or to control speed 1 of the fan coil managed by thermostat A or thermostat B. It also has an NC or NO programmable digital input that can be used for applications such as detecting an open window. The device is equipped with a display and four front buttons to control the temperature set-point and the speed of the fan-coil.
Main characteristics• this device contains only SELV circuits that must be kept separate
from circuits with dangerous voltage; • digital input for NO or NC contact (voltage-free, SELV); max dis-
tance between the input contact and the thermostat: 30 m;• input for temperature sensor (20432, 19432, 14432); maximum
length of sensor connecting cable to the devices: 60 m. Use a twisted cable with a minimum cross-section of 0.5 mm2 (01840);
• NO relay output ( 24 V~ SELV 4 A cosϕ 1; 24 V~ SELV 2 A cosϕ 0.6);
• temperature sensors that can be managed by the thermostat:- internal NTC;- possibility of connecting an external NTC (20432, 19432,
14432);• possibility of using the temperature values measured by 8 differ-
ent probes connected to the KNX Bus.
ConfigurationThe thermostat and its physical address, parameters, operation, etc. are all configured using the ETS software. If the thermostat is loaded with an incorrect ETS application, the red LED on the back of the device will flash and all the LCD segments will blink on the display (“device type” error). To restore the desired configuration, load the device with the correct ETS application. The user can use the front buttons to change the temperature set point and the speed of the fan-coil; changing these parameters forces the ther-mostat onto manual operation. With ETS it is possible to set the following parameters (directly from the graphic windows):• general settings; • temperature sensor;• temperature setpoint;• setpoint temperature;• input and output;• adjustment;• valve;• fan coil speed;• scenarios.
OperationUsing the thermostat it is possible to set:• the temperature set-point in the room (the change can only be
made within certain limits set by the control centre or reception, etc.);
• the speed of the fan-coil.
To change the temperature press the + or – button twice:• on pressing it the first time the display will show the currently set
temperature;• on pressing it the second time the increase/decrease in the dis-
played value will begin.
Compliance with standardsEMC directive, Standards EN 50090-2-2, EN 50428
Thermostat display
Room temperature Unit of measurement (Celsius/Fahrenheit)
Air conditioning/Heating
Display secondary thermostat (B)
Fan coil speed
Guest out of room function (Stand-by)
Antifreeze
System off
Operating mode(Manual/Automatic)
Economy
Device locked(cannot be controlled
locally)
ext
THERMOSTAT
OFF
A B C D
Front view and connectionsConfiguration button
Input
Common input
CRelay
NO
BUS line LED
External temperature sensor terminals
Button A: reduce temperature set-point.Button B: increase in temperature set-point.Button C: select thermostat to display/control (A or B) and display temperature of external probe (20432, 14432)Button D: increase/reduce the fan-coil speed.
Technical datapower supply from KNX Bus 30 Vdc SELVabsorption from KNX Bus 10 mA
reading accuracy - ≤ ± 0.5°C between +15°C and +30°C- ≤ ± 0.8°C at extremes
clock error - ≤ ± 1 s a day operating temperature from -5°C to +45°C (indoor use)
InputsKNX TP Bus EIB + -programmable digital input 1, 2
external temperature sensor (20432, 19432, 14432)
Outputs
NO relay 4 A 24 V~ NO, C
Well-contact Plus : thermostats for energy management
99
CLIMA&ENERGY
The side view drawings give the overall dimensions and the depth of the recess in mm
20430grey
16915grey
16915.Bwhite
14430white
14430.SLSilver
20430.Bwhite
19430grey
20430.NNext
19430.Bwhite
49
44,837
47,2
49,8
50
36,5
47,6
48
37 44,7
49
44,8
49
36
48,3
Electronic thermostatElectronic thermostat for ambient air temperature control (heating and air conditioning) of 2 independent zones, KNX standard, 1 NO 4 A 24 V~ relay output, 1 input for temperature sensor, 1 programmable digital input, 2 modules
IDEA
ARKÉ
PLANA
EIKON
WE
LL-C
ON
TAC
T P
LUS
THE
RM
OS
TATS
AN
D D
EVI
CE
S
Well-contact Plus : thermostats for energy management
100
CLIMA&ENERGYWell-contact Plus : energy management devices KNX standard weather stationThe weather station integrates with the Well-contact Plus system for managing temperature control, energy and automation systems. The KNX weather station measures variables such as temperature, wind speed, rain and brightness, the values of which can be used to control the device outputs based on limit values; the states can then be associated amongst themselves using the weather sta-tion's AND and OR logic gates.
Main functions• Brightness measurement: this function can be used to turn
exterior lights on at dusk and off at dawn.• Wind measurement: the strength of the wind is measured
electronically, so the measurement is quiet and reliable even in the event of hail, snow and sub-zero temperatures. The weather station is also able to detect whirlwinds and updraughts. This function can also be used to activate awning winding in the case of strong wind or precipitation.
• Rain measurement: the weather station is equipped with a sen-sor with a heated surface so that only rain and snow is measured as precipitation (and not fog or dew). Automatic irrigation can be deactivated in the event of rain. Once it has stopped raining or snowing, the sensor dries quickly and the precipitation message is turned off.
• Temperature measurement: the weather station measures the value of the current ambient temperature.
• Control outputs for all values: the limit values can be set via the respective parameters or via the ETS communication objects.
• 8 AND logic gates and 8 OR logic gates each with 4 inputs: the control operations themselves as well as the 8 logic inputs (in the form of communication objects) can be used as inputs for the AND and OR logic gates; the output of each gate can be config-ured as 1 bit or as 2 x 8 bits.
Main characteristics• configuration button;• CONFIGURATION LED;• protection class: IP44;• dimensions: 96x77x118 mm (L x H x D);• weight: approx. 170 g.
ConfigurationThe weather station functions and parameters are configured via the ETS software; the program file (in VD format), the manual and the technical info sheet are available for download in the Software->Product Software section of the website www.vimar.com.
Compliance with standardsEMC directive,Standards EN60730-1, EN 50491
Technical dataAUX power supply 12-32 V, 12-24 V~ SELVmax current draw, ripple 10% 100 mAgroup addresses 254 maxpossible associations 255 maxcommunication objects 109rain sensor heating 1.2 Wtemperature measurement range from -40°C to +80°Ctemperature definition 0.1°C
temperature accuracy 1°C from -10°C - +85°C1.5°C from -25°C - +150°C
wind measurement range 0 - 70 m/swind definition <10% of the reading
wind accuracy with an angle of incidence of 45° and mounting on a suitable support
25% from 0 - 15 m/s
brightness measurement range 0 - 150,000 Lux
brightness definition 1 Lux from 0-120 Lux2 Lux from 121-1,046 Lux63 Lux from 1,047-52,363 Lux423 Lux from 52,364-150,000 Lux
brightness accuracy 35%operating temperature from -30°C to +50°C (exterior use)
Inputspower supply +, -Bus TP bus
AUX12-32 Vdc12-24 Vac
AUX+,-
L N L N
Bus+,-
Bus +, -
0189
0
01500
01546 - Connections
KNX power unit:art. 01500
AUX power unit:art. 01830
or transformer:art. 16887
For availability, please contact the sales network
101
CLIMA&ENERGYWell-contact Plus : energy management devices
WE
LL-C
ON
TAC
T P
LUS
THE
RM
OS
TATS
AN
D D
EVI
CE
S
KNX standard weather station 01546 Weather station, KNX standard, supply voltage 12-32 Vdc or 12-24 Vac
01546
Installation
Base with straps supplied
103
CLIMA&ENERGY
TEMPERATURE CONTROL FOR STAND ALONE SYSTEMS from page 106
TEMPERATURE CONTROL AND ENERGY MANAGEMENTFOR STAND ALONE SYSTEMS
from page 109
TEMPERATURE CONTROL WITH BY-ME SYSTEM from page 111
ENERGY MANAGEMENT WITH BY-ME SYSTEM from page 115
TEMPERATURE CONTROL WITHWELL-CONTACT PLUS SYSTEM
from page 119
TEM
PE
RAT
UR
E C
ON
TRO
LFO
R S
TAN
D A
LON
ES
YS
TEM
S
TEM
PE
RAT
UR
E C
ON
TRO
L A
ND
EN
ER
GY
MA
NA
GE
ME
NT
FOR
STA
ND
ALO
NE
SY
STE
MS
TEM
PE
RAT
UR
E C
ON
TRO
LW
ITH
BY-
ME
SY
STE
ME
NE
RG
Y M
AN
AG
EM
EN
TW
ITH
BY-
ME
SY
STE
MTE
MP
ER
ATU
RE
CO
NTR
OL
WIT
HW
ELL
-CO
NTA
CT-
PLU
S S
YS
TEM
Installation examples
104
CLIMA&ENERGY
GSM (SIM card non fornita)
Smartphone
02906
01913(in alternativa al 02906)
CaldaiaSplit climatizzatore
01910+Modulo trasmettitore
radiofrequenza 01921.1
Attuatore-ricevitoread 1 canale 01923
01910
M d l t ttit
CaldaiaSplit climatizzatore
Examples with stand alone devices: temperature control
Note.
This solution for the single-zone heating/air conditioning system has a single control point. The GSM touch screen thermostat can also be controlled via a smartphone using the By-clima software.
Note.
This solution for the autonomous single-zone heating/air conditioning system has a single control point. The time-thermostat activates the boiler circulation pump by radio via the output of actuator-receiver 01923 according to the set point.
02900 - Electronic thermostat installation example.
02906 - GSM touch screen thermostat installation example.
01910 electronic time-thermostat and radiofrequency transmitter module 01921.1 in an independent heating system.
CaldaiaSplit climatizzatore
02900
Air-conditioning fan Heater
Air-conditioning fan
Air-conditioning fan
01923 - 1-chanel actuator-receiver
01921.1 - RF transmitter module
GSM (SIM not supplied)
(as an alternative to 02906)
Heater
Heater
105
CLIMA&ENERGYExamples with stand alone devices: temperature control
The diagrams are provided as examples only. For details on the correct size of the system, refer to the installation manual and technical pages in the catalogue.
Contatore di impulsi
Collettore didistribuzione
Ai pannelli radianti delle 4 zone
Elettrovalvole di zona
Collettore didistribuzione
A B C D
01910+Modulo trasmettitore
radiofrequenza 01921.1
Attuatore-ricevitorea 2 canali 01924
01910
M d l t ttit
01911+Modulo trasmettitore
radiofrequenza 01921.1M d l t ttit
Att t i it
01911
Elettrovalvolaprincipale
Multiple control points in a multizone heating/air conditioning system.
Note.
This solution for the autonomous or centralised heating/air conditioning system has a maximum of 4 control points for the various independent zones. Each time-thermostat equipped with a radiofrequency module communicates with the actuator-receiver 01924 to control an individual zone.
TEM
PE
RAT
UR
E C
ON
TRO
LFO
R S
TAN
D A
LON
ES
YS
TEM
S
01921.1 - RF transmitter module
Hydraulicmanifold
Hydraulicmanifold
To the 4-zone floor heating
Main solenoid valve
Zone solenoid valves
Pulse meter
01921.1 - RF transmitter module
01924 - 2-chanel actuator-receiver
106
CLIMA&ENERGYExample with stand alone devices: temperature controlMulti-zone heating/air conditioning system with unlimited control points and independent zones.
Note.
This solution for multi-zone heating/air conditioning system (with manual switching to boiler) has an unlimited number of control points for the independent zones.It is also possible to have a single centralised control for energy saving, system deactivation and summer/winter switching.
Interruttore, comando centralizzato(commutazione estate/inverno)
Sonda esterna 20432(per visualizzazione temperaturadi un altro ambiente)
Sonda lare 02965(alternativa alla 20432 perlimitazione temperatura pavimento)
Ai pannelli radianti delle 4 zone
Collettore didistribuzione
A
Zona A
Zona B
Zona C
Zona D
B C D
02910
02905
02955
02950
A
02
0
02
0
Interruttore, comando centralizzato(riduzione notturna)
Elettrovalvole di zona
Hydraulicmanifold
Zone solenoid valves
To the 4-zone floor heating
AREA A
AREA B
AREA C
AREA D
02965 - Wired probe(as an alternative to 20432 for testing floor temperature)
20432 - Outdoor probe(to test the temperature of another room)
Centralised switch(winter/summer switching)
Centralised switch(nighttime reduction)
107
CLIMA&ENERGY
The diagrams are provided as examples only. For details on the correct size of the system, refer to the installation manual and technical pages in the catalogue.
Single-phase system with monitoring of energy production by means of power meter 02960 and touch screen time-thermostat 02910.
Single-phase system with monitoring of energy consumption by means of power meter 02960 and flush mounting time-thermostat 02955.
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
Contatoredi produzione
Pannello fotovoltaico
L LN N
L NINVERTER
CENTRALINO
0291002915
+02960
L
N
01457(già inclusonell’art. 02960)
Contatoredi scambio
Rete elettrica
TV Piantana
LN 02910
+0296
01457(già presentenell’art. 02960)per produzioneimpiantofotovoltaico
Contatoredi produzione
Pannello fotovoltaico
L LN N
L N
INVERTER
CTRY OF MFGPAT. PEND
PA3832NL
DATE CODE
CENTRALINO
Contatoredi scambio
Protezioni
Rete elettrica
LN 029602960 0295502955
L
N
TV Piantana
Notes.
The example shows a single-phase system in which the power meter 02960 uses the toroidal current sensor 01457 to measure the energy produced by the photovoltaic system and allows the data (instantaneous power generated, average energy generated) to be displayed on the touch screen of time-thermostat 02910.
Notes.
The example shows a single-phase system in which the power meter 02960 uses the toroidal current sensor 01457 to measure the energy absorbed by the domestic loads and allows the data (power absorbed by the load and by the overall system, average energy consumed, meter trip alarm) to be displayed on the touch screen of flush-mounted time-thermostat 02955. It is also possible to monitor individual loads by connecting the toroidal sensor to the relevant power supply line.
Example with stand alone devices: temperature and energy management
TEM
PE
RAT
UR
E C
ON
TRO
L A
ND
EN
ER
GY
MA
NA
GE
ME
NT
FOR
STA
ND
ALO
NE
SY
STE
MS
Main supply
Main supply
Solar panel
Solar panel
Exchangemeter
Exchangemeter
Protection
Productionmeter
Productionmeter
supplied with 02960
(supplied with 02960) for production solar system
Floor lamp
CONSUMER UNIT
CONSUMER UNIT
Floor lamp
108
CLIMA&ENERGY
Interfacciaconta impulsi
01452
Bus 1/0
Interfacciaconta impulsi
01452
Bus 1/0
Interfacciaconta impulsi
01452
A Emettitore d’impulsiB Altro contatore d’impulsi
A
B+ - +
+
-
-
+
-
+
-
+-
Bus 1/0
+ - + -
Three-phase system with monitoring of energy production by means of power meter 02960 and touch screen time-thermostat 02910.
Three-phase system with monitoring of energy consumption by means of power meter 02960 and flush mounting time-thermostat 02955.
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
Contatoredi produzione
Pannello fotovoltaico
N L1 L2 L3NL1L2L3 L3L2NL1
N L1L2L3
N
L1
L2
L3INVERTER
CENTRALINO
0291002915
+02960
01457 x 3(1già incluso nell’art. 02960 + 2 opzionali)
Contatoredi scambio
Rete elettrica
02910
+0296
Forno Lavastoviglie Lavatrice Idromassaggio
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
Contatoredi produzione
Pannello fotovoltaico
N L1 L2 L3NL1L2L3 L3L2NL1
N L1L2L3
N
L1
L2
L3INVERTER
CENTRALINO
02960
01457 x 3(1già inclusonell’art. 02960+ 2 opzionali)
Contatoredi scambio
Rete elettrica
0296
Forno Lavastoviglie Lavatrice Idromassaggio
0295502955
Notes.
The example shows a three-phase system in which the power meter 02960 uses the toroidal current sensor 01457 to measure the energy produced by the photovoltaic system and allows the data (instantaneous power generated, average energy generated) to be displayed on the touch screen of time-thermostat 02910.
Notes.
The example shows a three-phase system in which the power meter 02960 uses the toroidal current sensor 01457 to measure the energy absorbed by the domestic loads and allows the data (power absorbed by the load and by the complete system, average energy consumed, meter trip alarm) to be displayed on the touch screen of flush mounting time-thermostat 02955.
Example with stand alone devices: temperature and energy management
Main supply
Main supply
Solar panel
Solar panel
Exchange meter
Exchange meter
(1 included into 02960 + 2 optionals)
Production meter
Production meter
1 provided with 02960 + 2 optional Oven
Oven
Dishwasher
Dishwasher
Washing machine
Washing machine
Whirlpool
Whirlpool
CONSUMER UNIT
CONSUMER UNIT
109
CLIMA&ENERGY
The diagrams are provided as examples only. For details on the correct size of the system, refer to the installation manual and technical pages in the catalogue.
Examples with By-me: temperature control
OUT 1OUT 2OUT 3OUT 4
Caldaia
Pompa dicircolazione
Pompa dicircolazione
Bus 1/0
Bus 1/0
Elettrovalvolazona A
Elettrovalvolazona B
Elettrovalvolazona C
Elettrovalvolazona D
19538
01851.2
01850.201400AUX +, -
21509
Touch screen per impostazionetemperatura ambienti
19538
19538
19538Zona D(come sopra)
Zona A(impianto a 2 tubi)
Zona B(come sopra)
Zona C(come sopra)
Controllo elettrovalvole di zona
By-me home automation system with multi-zone management of temperature regulation.
Note.
The example shows a convention 2-pipe heating system with radiators, circulation pump, zone valve and single boiler. Using the electronic temperature probes connected to the By-me bus, it is possible to set the climatic zones by means of the supervision touch screens present in the system or remotely via smartphone, PC or tablet if web server 01945 connected to the internet is present.
TEM
PE
RAT
UR
E C
ON
TRO
LW
ITH
BY-
ME
SY
STE
M
Area solenoid valves control
Area Asolenoid valve
Area A(2-pipe heating system)
Area B(2-pipe heating system)
Area C(2-pipe heating system)
Area D(2-pipe heating system)
Area Bsolenoid valve
Area Csolenoid valve
Area Dsolenoid valve
Circulation pump
Heater Touch screen for room temperature setting
Circulation pump
110
CLIMA&ENERGYExamples with By-me: temperature control
Zona A
Zona B
Zona C
Zona D
20584.1.B
02951.B
20538.B
02965
01851.2
02951 B
02951.B02951 B
02965
20538 B
20538.B20538 B
01400
01546
21511.B
21509.B
01400
21509 B
01546
0146501465
M Pompa di circolazioneAlta temperatura
Sonda dimandata
Pompa di circolazioneBassa temperatura
Pompa di circolazioneBassa temperatura
Split per condizionamento
Caldaia
Collettore
Collettore di distribuzione
21511 B
OUT 1OUT 2OUT 3OUT 4
Controllo elettrovalvole di zonadel collettore di distribuzione
Pompa di circolazioneAlta temperatura
01850.2
AUX +, -
AUX +, -Bus KNX
By-me home automation system with 4-zone temperature control.
Note.
The example shows an underfloor heating system with high-temperature towel warmers in the bathrooms and a single or multi split air conditioning system. It is controlled by the By-me home automation system by means of a touch screen control unit, thermostats, electronic temperature probes, actuators, IR interfaces and a weather station.
Air-conditioning fan
AREA A
AREA B
AREA C
AREA D
Circulation pumpLow-temperature
Circulation pumpLow-temperature
Circulation pumpHigh-temperature
Heater
Circulation pumpHigh-temperature
Area solenoid valves control
Manifold
Convey probe
Hydraulic manifold
111
CLIMA&ENERGY
The diagrams are provided as examples only. For details on the correct size of the system, refer to the installation manual and technical pages in the catalogue.
Examples with By-me: temperature control
Chiller
Pompe di circolazione principali
20433 01467
01851.2 02951
20538
01850.201466 01850.2
20538
21509
01400
01465
02951
02951 02951
01851.201851.2
Pompa dicircolazionesecondaria
Pompa dicircolazionesecondaria
20538 20538
014
21509
014650146501465
Zona A
Zona B
Zona C
Zona D
Zona E
Zona F
M M
21511
01546
AUX +, -
Sonda dimandata
Sonda dimandata
OUT 1OUT 2OUT 3OUT 4
Controllo elettrovalvole di zonadel collettore di distribuzione
OUT 1OUT 2OUT 3OUT 4
Controllo elettrovalvole di zonadel collettore di distribuzione
Bus KNX
AUX +, -
By-me home automation system with 6-zone temperature control.
Note.
The example shows a radiant panel heating/air conditioning system with a fan-coil backup for a 4 pipe system. The system features thermostats and electronic temperature and humidity probes connected to the By-me Bus for temperature control of rooms. From the home automation system's supervision touch screens it is possible to set the time programmes and the temperature set points of the individual zones.
TEM
PE
RAT
UR
E C
ON
TRO
LW
ITH
BY-
ME
SY
STE
M
Area solenoid valves control Area solenoid valves control
AREA A AREA D
AREA B AREA E
AREA C AREA F
Convey probe
Convey probeSecondary
circulation pumpSecondary
circulation pump
Main circulation pumps
112
CLIMA&ENERGYExamples with By-me: temperature control
CENTRALINO
01851.214511.1
Fancoil On/Off 3 velocità
Fan coil proporzionali a velocità variabile (0-10 V)
Fancoil On/Off 3 velocità
215092150901466
Bus 1/0
01851 2 01851.2
14538 14538
14538 14518
01851 2
MM
OUT 1, 2, 3, 4
01466
LN
014000140
OUT 1, 2, 3, 414538 14538
01820
Ufcio 1
Ufcio 3
Ufcio 2
AUX +, -
By-me home automation system with multi-zone temperature control in the service sector.
Note.
The example shows a heating system managed by the By-me home automation system in which 3-speed fan-coils are installed in two zones (offices 1 and 2), while the third zone (office 3) is equipped with variable-speed fan-coils (0-10V) with window opening control for energy saving (with configurable delay).
OFFICE 1
3-speed ON/OFF fan coil
Variable speed fan coils (0-10 V)
3-speed ON/OFF fan coil
OFFICE 3
OFFICE 2
CONSUMER UNIT
113
CLIMA&ENERGY
The diagrams are provided as examples only. For details on the correct size of the system, refer to the installation manual and technical pages in the catalogue.
Single-phase system (up to 33 kW total) with control of 4 loads and measurement of consumption of 4 single loads (oven, dishwasher, washing machine and dryer).
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CENTRALINO
01455
LN
01457(già incluso nell’art. 01455)
Contatore
Bus 1/0Rete elettrica
LN 2150921509 01400
Forno Lavastoviglie Lavatrice Asciugatrice
01456 01456 01456 01456
Note.Up to 16 loads or groups of loads that can be controlled by controlling the same number of relay actuators. The groups of controlled loads must be assigned a priority that determines the order in which they are disconnected.It is possible to measure the absorption of up to max 20 loads or groups of loads.
Single-phase system (up to 33 kW total) with 4 loads, display of individual loads and test (optional) of loads losses to earth.
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY OF MFG PAT. PEND
PA3832NL
DATE CODE
CTRY OF MFG PAT. PEND
PA3832NL
DATE CODE
CTRY OF MFG PAT. PEND
PA3832NL
DATE CODE
CTRY OF MFG PAT. PEND
PA3832NL
DATE CODE
CENTRALINO
0140001455 LN
01457(già incluso nell’art. 01455)
01459 (x4 opzionali)per la diagnosi della dispersionedel carico verso terra
Contatore
Rete elettrica
Forno Lavastoviglie Lavatrice Asciugatrice
LN 2150921509 0145601456 01456 01456
Bus 1/0
Notes.Up to 16 loads or groups of loads that can be controlled by controlling the same number of relay actuators. The groups of controlled loads must be assigned a priority that determines the order in which they are disconnected.
It is possible to measure the absorption of up to max 20 loads or groups of loads.
Examples with By-me: energy management
EN
ER
GY
MA
NA
GE
ME
NT
WIT
H B
Y-M
E S
YS
TEM
Main supply
Meter
(provided with 01455)
01459 (x4 optionals)to test loads lossesto earth
Oven Dishwasher Washing machine
Dryer
CONSUMER UNIT
provided with 01455
Meter
Oven Dishwasher Washing machine
Dryer
CONSUMER UNIT
114
CLIMA&ENERGY
Single-phase system (up to 33 kW total) with control of 4 loads, measurement of consumption of 1 load (oven, dishwasher, washing machine, dryer) and measurement of photovoltaic production (optional).There is a single control unit shared by all devices.
Contatoredi produzione
Pannello fotovoltaico
L N
L N
INVERTER
CTRY OF MFG PAT. PEND
PA3832NL
DATE CODE
CTRY OF MFGPAT. PEND
PA3832NL
DATE CODE
CENTRALINO
01455
LN
01457(già incluso nell’art. 01455)
01457(opzionale)
Contatoredi scambio
Rete elettrica
Forno Lavastoviglie Lavatrice Asciugatrice
LN 2150921509
Bus 1/0
0140001456 01456 01456 01456
Notes.Up to 16 loads or groups of loads that can be controlled by controlling the same number of relay actuators. The groups of controlled loads must be assigned a priority that determines the order in which they are disconnected.
By setting the parameter "Production threshold" on a control group, the load activates when the power fed to the operator exceeds the threshold and remains active as long as produc-tion exceeds total consumption. By suitably configuring the parameters Minimum ON time", the load control logic activates the load when the production threshold is achieved or passed, keeping it active for the minimum set time.
Examples with By-me: energy management
Main supply
Solar panels
provided with 01455
optional
Exchangemeter
Productionmeter
Oven Dishwasher Washing machine
Dryer
CONSUMER UNIT
115
CLIMA&ENERGYExamples with By-me: energy management
EN
ER
GY
MA
NA
GE
ME
NT
WIT
H B
Y-M
E S
YS
TEM
Three-phase system (up to 100 kW total) with control of 4 single-phase loads on different phases.
CENTRALINO
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
01455 L1N
01458 (x3)(opzionali)
Contatore
Rete elettrica
Forno Lavastoviglie Lavatrice Idromassaggio
L1L2L3
L2L1
L3
N 2150921509
Bus 1/0
01456 01456 01456 01456 01400
Note.Up to 16 loads or groups of loads that can be controlled by controlling the same number of relay actuators. The groups of controlled loads must be assigned a priority that determines the order in which they are disconnected.
Oven Dishwasher Washing machine
Whirlpool
Main supply
Meter
optional CONSUMER UNIT
116
CLIMA&ENERGY
Single-phase system (up to 33 kW total) with control of 4 loads and energy production with photovoltaic panels and devices inserted in a dedicated control unit.
Notes.Up to 16 loads or groups of loads that can be controlled by controlling the same number of relay actuators. The groups of controlled loads must be assigned a priority that determines the order in which they are disconnected.
By setting the parameter "Production threshold" on a control group, the load activates when the power fed to the operator exceeds the threshold and remains active as long as production exceeds total consumption. By suitably configuring the parameters "Minimum ON time", the load control logic activates when the production threshold is achieved or passed, keeping it active for the minimum set time.
Examples with By-me: energy management
CTRY OF MFGPAT. PEND
PA3832NL
DATE CODE 01457 (già incluso nell’art.01455) per consumo totale
01457 (già presentenell’art. 01450)
per produzione impiantofotovoltaico
Contatoredi produzione
Pannello fotovoltaico
L N
L N
INVERTER
CTRY OF MFG PAT. PEND
PA3832NL
DATE CODE
CENTRALINO 2CENTRALINO 1
0145501450
Contatoredi scambio
Protezioni
Rete elettrica
LN 2150921509145
Bus 1/0
0145601456 01456 01456
Forno Lavastoviglie Lavatrice Asciugatrice
L N014001400
CONSUMER UNIT 1
CONSUMER UNIT 2
Main supply
Solar panels
Productionmeter
Exchangemeter
Protections
01457 (provided with 01455) for total consuption
Oven Dishwasher Washing machine
Dryer
117
CLIMA&ENERGY
EN
ER
GY
MA
NA
GE
ME
NT
WIT
H B
Y-M
E S
YS
TEM
The diagrams are provided as examples only. For details on the correct size of the system, refer to the installation manual and technical pages in the catalogue.
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
Attuatoreda incasso
20537 20210
L
L
N
N
Lavatrice
0L N
Attuatoreda guida DIN
01456
20210
L
L
N N
Lavatrice
0
eN6
Attuatoreda guida DIN
01456
20210
01459(opzionale)L
L
N
N Lavatrice
0
eN6
Bus 1/0
Bus 1/0 Bus 1/0
System with display of single loads control by actuator 16 A.
Flush mounting actuator.
Actuator for DIN rail. Actuator for DIN rail, with optional probe for diagnostics of differential current loss to earth.
Note.
It is possible to measure the absorption of up to 20 loads or groups of loads.
Examples with By-me: energy management
20537Actuator
01456Actuator
01456Actuator
01459optional
Washing machine
Washing machine
Washing machine
118
CLIMA&ENERGY
System with display of individual loads with power meter.
Misuratoredi energia
01451 20210
L
LL1 L N
N
N 0
L NL1 L N
Bus 1/0
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
CTRY O
F MFG
PAT. PEN
D
PA38
32NL
DATE
CODE
Misuratoredi energia
01450
Sensori di corrente 01457 (x3), 1 già incluso nell’art.01450 più 2 opzionali
20210
L
L
N
N L N L N 0
L N20210
L N0 20210
L N0
ea0
Bus 1/0
Power meter 01451 with 1 input. Power meter 01450 with 3 inputs.
Note.
It is possible to measure the absorption of up to 20 loads or groups of loads.
Display of non-electrical utilities (water, natural gas) by connecting to pulse counter.
Interfacciaconta impulsi
01452
Bus 1/0
Interfacciaconta impulsi
01452
Bus 1/0
Interfacciaconta impulsi
01452
A Emettitore d’impulsiB Altro contatore d’impulsi
A
B+ - +
+
-
-
+
-
+
-
+-
Bus 1/0
+ - + -
Interfacciaconta impulsi
01452
Bus 1/0
Interfacciaconta impulsi
01452
Bus 1/0
Interfacciaconta impulsi
01452
A Emettitore d’impulsiB Altro contatore d’impulsi
A
B+ - +
+
-
-
+
-
+
-
+-
Bus 1/0
+ - + -
Example of a second metering device.
Note.
It is possible to measure the absorption of up to 20 loads or groups of loads.
Examples with By-me: energy management
01451Energy meter
01450Energy meter
01457 (x3) supply sensor, 1 provided with 01450
01452Pulse meter
interface
01452Pulse meter
interface
A: Pulse maker
B: Additional pulse meter
01452Pulse meter
interface
119
CLIMA&ENERGY
The diagrams are provided as examples only. For details on the correct size of the system, refer to the installation manual and technical pages in the catalogue.
Examples of Well-contact Plus : temperature control
CENTRALINO
01522
01540 01500
0295219518 19432
Fancoil On/Off 3 velocità
PC in reception con softwareWell-contact Suite
Fancoil On/Off 3 velocità
Bus KNX
Bus KNX
MM
OUT 1, 2, 3, 4
LN
OUT 1, 2, 3, 4
01820
C f
01500
01522
02952
0295202965
01546
02952
01820
19
Ufcio 1 Ufcio 2
Altre zone
Gatewayper sistemi
di terzeparti
19518 1951819518
01546
02965
AUX +, -
Well-contact Plus building automation: system with multi-zone temperature control in the service sector.
Note.
The example shows a heating system controlled by the Well-contact Plus automation system which features thermostats and NTC electronic temperature sensors for temperature control in large spaces (open-space offices) with 3-speed fan-coils and integration by means of a KNX standard gateway with third party heating systems. The opening of windows is detected to avoid energy wastage by means of magnetic contacts installed on the windows themselves.
TEM
PE
RAT
UR
E C
ON
TRO
L W
ITH
WE
LL-C
ON
TAC
T-P
LUS
SY
STE
M
OFFICE 1
OTHER AREAS
Gatewayto other systems
3-speed ON/OFF fan coil
PC in reception with Well-contact suite software installed
3-speed ON/OFF fan coil
OFFICE 2
CONSUMER UNIT
Vimar reserves the right to change the stated features of the products at any time and without notice. Due to the graphic layout, the photos and drawings of the products are not shown with equivalent proportions.