Radiating and Coupling Cable Systems Radiating cables are used wherever normal radio communication is difficult or impossible, in particular in communication systems where a discrete antenna would not provide adequate coverage, such as in tunnels, underground railways, mines, buildings, etc. RF energy is simultaneously transmitted down radiating cables and radiated from all points along them into the surrounding space. Slots cut into the outer conductor of the coaxial cable allow controlled levels of electromagnetic energy to be radiated both out of and into the cable.

Cables Characteristics Radiating Cable 1/2" Radiating Leaky Feeder Slexrtd RF 450-2600 MHz Radiating Cable 1/2" Radiating Leaky Feeder Silexrtd RF 150-900 MHz Radiating Cable 1/2" Coupling Leaky Feeder Silexrtd RF 75-2400 MHz Radiating Cable 1/2" Coupling2 Leaky Feeder Silexrtd RF 75-2400 MHz Radiating Cable 7/8" Radiating Leaky Feeder Slexrtd RF 75-2700 MHz Radiating Cable 7/8" Radiating Leaky Feeder Slexrtd RF 75-960 MHz Radiating Cable 7/8" Coupling Leaky Feeder Slexrtd RF 75-2400 MHz Radiating Cable 7/8" Coupling2 Leaky Feeder Slexrtd RF 75-2400 MHz Radiating Cable 1-1/4" Radiating Leaky Feeder Slexrtd RF 75-2700 MHz Radiating Cable 1-1/4" Radiating Leaky Feeder Slexrtd RF 75-960 MH Radiating Cable 1-1/4" Coupling Leaky Feeder Slexrtd RF 75-2400 MHz Radiating Cable 1-5/8" Radiating Leaky Feeder Slexrtd RF 75-2700 MHz Radiating Cable 1-5/8" Radiating Leaky Feeder Slexrtd RF 75-2500 MHz Radiating Cable 1-5/8" Radiating Leaky Feeder Slexrtd RF 75-960 MHz Radiating Cable 1-5/8" Coupling Leaky Feeder Slexrtd RF 75-2400 MHz Connectors Systems Radiating Connector DIN 7/16 Type Radiating Connector N Type

Radiating Clamp Systems Fix Metalic System Camp Plastic System Camp

Page 3: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.

RCF12R26(Z)(R)

Coaxial Radiating Cable, Broadband from 450 –2600 MHz, 1/2 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCAY(Z)(R)-50-12(1/2"C)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1/2" Inner Conductor Diameter 4.80 mm | 0.1890" Dielectric Diameter 12.30 mm | 0.4843" Outer Conductor Diameter 12.60 mm | 0.4961" Diameter Over Jacket 15.50 mm | 0.6102"

Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 125 mm Multiple bending radius 350 mm Minimum Distance to Wall 50 mm Tensile Strength 1000 N Bending Moment 13.5N.m Flat Plate Crush Strength 200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 4: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

86% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

6 KV

Inner Conductor DC Resistance

1.60 Ω/km Outer Conductor DC Resistance

4.30 Ω/km

Stop Band

1012~1052MHz & 2025~2110MHz Operating Frequency Band

700~2700 MHz

VSWR 800~960 MHz

≤1.30 1700~2025 MHz

≤1.40

2110~2170 MHz

≤1.40 2300~2700 MHz

≤1.40

ELECTRICAL PERFORMANCE

Frequency Attenuation Coupling Loss

(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

450 005 1,58 82 90 800 007 2,19 69 73 900 008 2,35 68 72

1800 012 3,63 65 68 2000 013 3,96 67 70 2100 014 4,18 65 69 2200 014 4,27 65 68 2400 016 4,72 63 66 2600 016 4,91 64 68

Page 5: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports.

RLK12R9(Z)(R)

Coaxial Radiating Cable, Broadband from 150 –900 MHz, 1/2 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCAY(Z)(R)-50-12(1/2"D)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1/2" Inner Conductor Diameter 4.80 mm | 0.1890" Dielectric Diameter 12.30 mm | 0.4843" Outer Conductor Diameter 12.60 mm | 0.4961" Diameter Over Jacket 15.50 mm | 0.6102"

Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 125 mm Multiple bending radius 350 mm Minimum Distance to Wall 50 mm Tensile Strength 1000 N Bending Moment 13.5N.m Flat Plate Crush Strength 200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 6: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

88% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

6 KV

Inner Conductor DC Resistance

1.48 Ω/km Outer Conductor DC Resistance

3.40 Ω/km

VSWR

0.3 ~ 0.5 GHz

≤1.30

0.8 ~ 1.0 GHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation

Coupling Loss

(2m) MHz dB/100 m

50%(dB) 95%(dB)

150 3.30

62 70 450 5.90

65 70

800 8.40

64 70 900 9.10

63 70

Page 7: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.

RCF12C24(Z)

Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 1/2 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCAY(Z)-50-12(1/2")

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1/2" Inner Conductor Diameter 4.80 mm | 0.1890" Dielectric Diameter 12.30 mm | 0.4843" Outer Conductor Diameter 13.80 mm | 0.4961" Diameter Over Jacket 15.70 mm | 0.6102"

Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 50mm Multiple bending radius 350 mm Minimum Distance to Wall 50 mm Tensile Strength 1000 N Bending Moment 13.5N.m Flat Plate Crush Strength 200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 8: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

76.0 pF/m Impedance

50±2 Ω

Velocity

86% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

6 KV

Inner Conductor DC Resistance

1.50 Ω/km Outer Conductor DC Resistance

3.00 Ω/km

Stop Band

- Operating Frequency Band

75~2400 MHz

VSWR 0.3~0.5 GHz

≤1.30 0.8~1.0 GHz

≤1.30

1.7~2.7GHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 2,1 0,6 69 77

150 3 0,9 70 80

450 5,5 1,7 70 80

800 7,5 2,3 72 83

900 8,1 2,5 72 83

1800 12,4 3,8 77 86

2200 13,9 4,2 78 87

2400 14,5 4,4 78 86

Page 9: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.

RCF12C224(Z)

Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 1/2 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCAY(Z)-50-12(1/2")

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1/2" Inner Conductor Diameter 4.80 mm | 0.1890" Dielectric Diameter 12.30 mm | 0.4843" Outer Conductor Diameter 13.80 mm | 0.4961" Diameter Over Jacket 15.70 mm | 0.6102"

Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 50mm Multiple bending radius 350 mm Minimum Distance to Wall 50 mm Tensile Strength 1000 N Bending Moment 13.5N.m Flat Plate Crush Strength 200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 10: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

76.0 pF/m Impedance

50±2 Ω

Velocity

88% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

6 KV

Inner Conductor DC Resistance

1.50 Ω/km Outer Conductor DC Resistance

3.10 Ω/km

Stop Band

- Operating Frequency Band

75~2400 MHz

VSWR 0.3~0.5 GHz

≤1.30 0.8~1.0 GHz

≤1.30

1.7~2.7GHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 2,1 0,63 66 76

150 03 0,94 67 78

450 5,7 1,74 67 78

800 7,9 2,41 71 80

900 8,2 2,5 70 80

1800 12,9 3,93 69 81

2200 14,5 4,42 72 82

2400 15,5 4,72 75 83

Page 11: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.

RCF78R27(Z)(R)

Coaxial Radiating Cable, Broadband from 75 –2700 MHz, 7/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)(R)-50-23(7/8"C)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 7/8" Inner Conductor Diameter 9.45 mm | 0.3720" Dielectric Diameter 22.80 mm | 0.8976" Outer Conductor Diameter 23.50 mm | 0.9370" Diameter Over Jacket 27.20 mm | 1.0709"

Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil

Jacket Black PE or Low Smoke Halogen-free Fire-retardant

Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 250 mm Multiple bending radius 500 mm Minimum Distance to Wall 50 mm Tensile Strength 1350 N Bending Moment 14.9N.m Flat Plate Crush Strength 400kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 12: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

89% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

10 KV

Inner Conductor DC Resistance

1.80 Ω/km Outer Conductor DC Resistance

2.90 Ω/km

Stop Band

1012~1052MHz & 2025~2110MHz Operating Frequency Band

75~2700 MHz

Optimum Operating Frequency Band

700~2700 MHz VSWR

800~960 MHz

≤1.30 1700~2025 MHz

≤1.30

2110~2170 MHz

≤1.30 2300~2700 MHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 001 000 70 79 100 002 0,46 70 81 150 002 0,55 78 89 350 003 0,88 83 93 450 003 1,04 85 95 700 004 1,19 73 77 800 004 1,22 70 73 900 004 1,28 69 72

1800 007 1,98 65 68 1900 007 002 64 67 2200 008 2,38 63 66 2400 008 003 62 65 2600 009 2,87 62 66 2700 011 3,23 62 66

Page 13: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.

RLK78R10(Z)(R)

Coaxial Radiating Cable, Broadband from 75 –960 MHz, 7/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)(R)-50-23(7/8"D)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 7/8" Inner Conductor Diameter 9.45 mm | 0.3720" Dielectric Diameter 22.80 mm | 0.8976" Outer Conductor Diameter 23.20 mm | 0.9134" Diameter Over Jacket 27.20 mm | 1.0709"

Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil

Jacket Black PE or Low Smoke Halogen-free Fire-retardant

Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 250 mm Multiple bending radius 500 mm Minimum Distance to Wall 50 mm Tensile Strength 1350 N Bending Moment 14.9N.m Flat Plate Crush Strength 400kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 14: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

89% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

10 KV

Inner Conductor DC Resistance

1.80 Ω/km Outer Conductor DC Resistance

3.00 Ω/km

Stop Band

180~280MHz & 500~580MHz Operating Frequency Band

75~1000 MHz

VSWR 800~960 MHz

≤1.30 1700~2025 MHz

≤1.30

2110~2170 MHz

≤1.30 2300~2700 MHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 001 000 60 70 100 002 0,49 62 65 150 002 0,58 63 73 350 003 0,91 62 65 450 004 1,07 66 71 650 004 1,25 61 68 800 005 1,43 60 62 900 005 1,52 58 61 960 005 1,62 57 60

Page 15: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.

RCF78C24(Z)(R)

Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 7/8 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)-50-22(7/8")

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 7/8" Inner Conductor Diameter 9.00 mm | Dielectric Diameter 22.30 mm | Outer Conductor Diameter 24.90 mm | Diameter Over Jacket 27.50 mm |

Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 90mm Multiple bending radius 500 mm Minimum Distance to Wall 50 mm Tensile Strength 1470 N Bending Moment 14.9N.m Flat Plate Crush Strength 400kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 16: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

76.0 pF/m Impedance

50±2 Ω

Velocity

86% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

6 KV

Inner Conductor DC Resistance

1.65 Ω/km Outer Conductor DC Resistance

1.90 Ω/km

Stop Band

- Operating Frequency Band

75~2400 MHz

VSWR 0.3~0.5 GHz

≤1.30 0.8~1.0 GHz

≤1.30

1.7~2.7GHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 1,2 0,4 63 72

150 2 0,5 65 75

450 3,2 1 71 79

800 4,4 1,3 75 83

900 4,7 1,4 76 85

1800 7,1 2,2 77 87

2200 8 2,4 78 86

2400 8,9 2,7 77 87

Page 17: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.

RCF78C224(Z)

Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 7/8 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)-50-22-2(7/8")

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 7/8" Inner Conductor Diameter 9.00 mm | Dielectric Diameter 22.30 mm | Outer Conductor Diameter 24.90 mm | Diameter Over Jacket 27.50 mm |

Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 90mm Multiple bending radius 500 mm Minimum Distance to Wall 50 mm Tensile Strength 1470 N Bending Moment 14.9N.m Flat Plate Crush Strength 400kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 18: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

76.0 pF/m Impedance

50±2 Ω

Velocity

86% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

10 KV

Inner Conductor DC Resistance

1.65 Ω/km Outer Conductor DC Resistance

2.10 Ω/km

Stop Band

- Operating Frequency Band

75~2400 MHz

VSWR 0.3~0.5 GHz

≤1.30 0.8~1.0 GHz

≤1.30

1.7~2.7GHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 1,2 0,4 63 72

150 2 0,5 65 75

450 3,2 1 71 79

800 4,4 1,3 75 83

900 4,7 1,4 76 85

1800 7,1 2,2 77 87

2200 8 2,4 78 86

2400 8,9 2,7 77 87 Maximum attenuation value shall be 105% of the nominal attenuation value

Page 19: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.

RCF114R27(Z)(R)

Coaxial Radiating Cable, Broadband from 75 –2700 MHz, 1-1/4” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)(R)-50-32(1-1/4"C)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1-1/4" Inner Conductor Diameter 13.00 mm | 0.5118" Dielectric Diameter 32.80 mm | 1.2913" Outer Conductor Diameter 33.20 mm | 1.3071" Diameter Over Jacket 37.80 mm | 1.5039"

Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil

Jacket Black PE or Low Smoke Halogen-free Fire-retardant

Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 400 mm Multiple bending radius 800 mm Minimum Distance to Wall 50 mm Tensile Strength 2500 N Bending Moment 15.5N.m Flat Plate Crush Strength 1000kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 20: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

89% Insulation Resistance

>5000 MΩ•km

Jacket Spark

8 KV Insulation Voltage

10 KV

Inner Conductor DC Resistance

1.00 Ω/km Outer Conductor DC Resistance

2.40 Ω/km

Stop Band

1012~1052MHz & 2025~2110MHz Operating Frequency Band

75~2700 MHz

Optimum Operating Frequency Band

700~2700 MHz VSWR

800~960 MHz

≤1.30 1700~2025 MHz

≤1.30

2110~2170 MHz

≤1.30 2300~2700 MHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 001 0,24 70 78 100 001 000 69 79 150 001 0,34 80 90 350 002 0,55 84 94 450 002 0,61 83 94 700 003 0,82 75 79 800 003 0,88 70 73 900 003 0,94 69 72

1800 005 1,62 66 69 1900 006 1,77 66 68 2200 006 1,95 65 68 2400 007 2,19 63 66 2600 008 2,41 64 67 2700 009 2,62 63 66

Page 21: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.

RLK114R10(Z)(R)

Coaxial Radiating Cable, Broadband from 75 –960 MHz, 1-1/4” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)(R)-50-32(1-1/4"D)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1-1/4" Inner Conductor Diameter 13.00 mm | 0.5118" Dielectric Diameter 32.80 mm | 1.2913" Outer Conductor Diameter 33.20 mm | 1.3071" Diameter Over Jacket 37.80 mm | 1.5039"

Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil

Jacket Black PE or Low Smoke Halogen-free Fire-retardant

Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 400 mm Multiple bending radius 800 mm Minimum Distance to Wall 50 mm Tensile Strength 2500 N Bending Moment 15.5N.m Flat Plate Crush Strength 1000kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 22: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

89% Insulation Resistance

>5000 MΩ•km

Jacket Spark

10 KV Insulation Voltage

10 KV

Inner Conductor DC Resistance

1.00 Ω/km Outer Conductor DC Resistance

2.40 Ω/km

Stop Band

180~280MHz & 500~580MHz Operating Frequency Band

75~1000 MHz

VSWR 75~150 MHz

≤1.30 300~500 MHz

≤1.30

600~750 MHz

≤1.30 806~960 MHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 001 0,24 63 73 100 001 000 64 74 150 001 0,37 65 76 350 002 0,58 64 68 450 002 0,64 67 72 650 003 0,82 65 69 800 003 0,94 59 61 900 003 1,04 58 60 960 004 1,19 58 62

Page 23: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.

RCF114C24(Z)

Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 1-1/4 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)-50-32(1-1/4")

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 7/8" Inner Conductor Diameter 13.00 mm | Dielectric Diameter 32.50 mm | Outer Conductor Diameter 35.80 mm | Diameter Over Jacket 38.60 mm |

Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 150mm Multiple bending radius 700 mm Minimum Distance to Wall 50 mm Tensile Strength 2900 N Bending Moment 15.5N.m Flat Plate Crush Strength 1000kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 24: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

76.0 pF/m Impedance

50±2 Ω

Velocity

88% Insulation Resistance

>5000 MΩ•km

Jacket Spark

10 KV Insulation Voltage

10 KV

Inner Conductor DC Resistance

1 Ω/km Outer Conductor DC Resistance

1 Ω/km

Stop Band

- Operating Frequency Band

75~2400 MHz

VSWR 0.3~0.5 GHz

≤1.30 0.8~1.0 GHz

≤1.30

1.7~2.7GHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 0,8 0,24 61 71

150 1,1 0,34 64 74

450 2,5 0,76 75 85

800 3,3 1,01 76 86

900 3,5 1,07 76 86

1800 5 1,52 77 87

2200 5,9 1,8 77 87

2400 6,5 1,98 78 88 Maximum attenuation value shall be 105% of the nominal attenuation value

Page 25: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.

RCF158R27(Z)(R)

Coaxial Radiating Cable, Broadband from 75 –2700 MHz, 1-5/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLHTY(Z)(R)-50-42(1-5/8"C1)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1-5/8" Inner Conductor Diameter 17.40 mm | 0.6850" Dielectric Diameter 42.80 mm | 1.6850" Outer Conductor Diameter 43.50 mm | 1.7126" Diameter Over Jacket 48.00 mm | 1.8898"

Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil

Jacket Black PE or Low Smoke Halogen-free Fire-retardant

Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 510 mm Multiple bending radius 900 mm Minimum Distance to Wall 50 mm Tensile Strength 3000 N Bending Moment 16.0N.m Flat Plate Crush Strength 1500kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 26: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

89% Insulation Resistance

>5000 MΩ•km

Jacket Spark

10 KV Insulation Voltage

15 KV

Inner Conductor DC Resistance

1.50 Ω/km Outer Conductor DC Resistance

1.50 Ω/km

Stop Band

1012~1052MHz & 2025~2110MHz Operating Frequency Band

75~2700 MHz

Optimum Operating Frequency Band

700~2700 MHz VSWR

75~150 MHz

≤1.30 800~960 MHz

≤1.30

1700~2025 MHz

≤1.30 2110~2170 MHz

≤1.30

2300~2700 MHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 001 0,18 70 79 100 001 0,24 70 81 150 001 0,27 78 90 350 001 000 83 93 450 002 0,46 83 94 700 002 0,58 74 77 800 002 0,64 70 72 900 002 001 69 71

1800 004 1,19 64 68 1900 004 1,28 63 66 2000 004 1,34 63 66 2200 005 1,46 63 65 2400 005 1,62 62 64 2600 006 1,83 63 65 2700 007 002 63 66

Page 27: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.

RCF158R25(Z)(R)

Coaxial Radiating Cable, Broadband from 75 –2500 MHz, 1-5/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLHTY(Z)(R)-50-42(1-5/8"C2)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1-5/8" Inner Conductor Diameter 17.40 mm | 0.6850" Dielectric Diameter 42.80 mm | 1.6850" Outer Conductor Diameter 43.50 mm | 1.7126" Diameter Over Jacket 48.00 mm | 1.8898"

Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil

Jacket Black PE or Low Smoke Halogen-free Fire-retardant

Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 510 mm Multiple bending radius 900 mm Minimum Distance to Wall 50 mm Tensile Strength 3000 N Bending Moment 16.0N.m Flat Plate Crush Strength 1500kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 28: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

89% Insulation Resistance

>5000 MΩ•km

Jacket Spark

10 KV Insulation Voltage

15 KV

Inner Conductor DC Resistance

1.50 Ω/km Outer Conductor DC Resistance

1.50 Ω/km

Stop Band

1012~1052MHz & 2025~2110MHz Operating Frequency Band

75~2500 MHz

Optimum Operating Frequency Band

700~2500 MHz VSWR

800~960 MHz

≤1.30

1700~2025 MHz

≤1.30 2110~2170 MHz

≤1.30

2300~2700 MHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 001 0,18 70 79 100 001 0,24 70 81 150 001 0,27 78 90 350 001 000 83 93 450 002 0,46 83 94 700 002 0,58 74 77 800 002 0,64 67 68 900 002 001 66 68

1800 004 1,22 62 65 1900 004 1,31 63 65 2000 005 001 61 63 2100 005 1,46 59 62 2200 005 1,62 59 62 2400 006 1,89 57 61 2500 007 002 57 62

Page 29: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.

RLK158R10(Z)(R)

Coaxial Radiating Cable, Broadband from 75 –960 MHz, 1-5/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLHTY(Z)(R)-50-42(1-5/8"D)

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 1-5/8" Inner Conductor Diameter 17.40 mm | 0.6850" Dielectric Diameter 42.80 mm | 1.6850" Outer Conductor Diameter 43.50 mm | 1.7126" Diameter Over Jacket 48.00 mm | 1.8898"

Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil

Jacket Black PE or Low Smoke Halogen-free Fire-retardant

Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 510 mm Multiple bending radius 900 mm Minimum Distance to Wall 50 mm Tensile Strength 3000 N Bending Moment 16.0N.m Flat Plate Crush Strength 1500kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 30: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

75.0 pF/m Impedance

50±2 Ω

Velocity

89% Insulation Resistance

>50000 MΩ•km

Jacket Spark

10 KV Insulation Voltage

15 KV

Inner Conductor DC Resistance

1.50 Ω/km Outer Conductor DC Resistance

1.50 Ω/km

Stop Band

180~280MHz & 500~580MHz

Operating Frequency Band

75~1000 MHz VSWR

75~150 MHz

≤1.30 300~500 MHz

≤1.30

600~750 MHz

≤1.30 806~960 MHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 001 0,18 63 73 100 0,85 0,26 64 73 150 001 0,27 67 77 350 001 0,43 67 70 450 002 0,49 67 71 650 002 0,61 63 67 800 002 0,73 58 61 900 003 0,79 58 60 960 003 0,88 59 61

Page 31: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.

RCF158C24(Z)

Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 1-5/8 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLHTY(Z)-50-42(1-5/8")

PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS

Nominal Size 7/8" Inner Conductor Diameter 17.40 mm | Dielectric Diameter 42.80 mm | Outer Conductor Diameter 46.50 mm | Diameter Over Jacket 49.50 mm |

Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black

MECHANICAL SPECIFICATIONS

Single Bending radius 510mm Multiple bending radius 900 mm Minimum Distance to Wall 50 mm Tensile Strength 3300 N Bending Moment 16 N.m Flat Plate Crush Strength 1200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1

ENVIRONMENTAL SPECIFICATION STANDARD CONDITION

Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES

As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)

Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB

Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.

Page 32: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

ELECTRICAL SPECIFICATIONS

Capacitance

76.0 pF/m Impedance

50±2 Ω

Velocity

88% Insulation Resistance

>5000 MΩ•km

Jacket Spark

10 KV Insulation Voltage

15 KV

Inner Conductor DC Resistance

1.50 Ω/km Outer Conductor DC Resistance

0.80 Ω/km

Stop Band

- Operating Frequency Band

75~2400 MHz

VSWR 0.3~0.5 GHz

≤1.30 0.8~1.0 GHz

≤1.30

1.7~2.7GHz

≤1.30

ELECTRICAL PERFORMANCE

Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)

75 0,6 0,18 68 78

150 0,8 0,24 71 81

450 1,9 0,58 75 85

800 2,6 0,79 75 85

900 2,7 0,82 75 84

1800 4,4 1,34 77 86

2200 5,1 1,55 77 86

2400 5,5 1,68 77 86 Maximum attenuation value shall be 105% of the nominal attenuation value

Page 33: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Radiating Connectors

Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. The connectors are designed according the standard inter-faces N and 7/16 Type. Contact components are silver platedto minimize insertion loss, mechanical parts are nickel platedfor heavy-duty handling and best corrosion resistance.

Radiating Connectors N – 7/16

FEATURES and BENEFITS

• High contact force and Cu-Be inner contacts • Silver plated • Watertight (IP67) • Corrosion resistant • Quick trimming • Installation "fit on and tighten it"

MECHANICAL SPECIFICATIONS

CONNECTORS CHARACTERISTICS AND TARGET

structure Characteristics N Type Din 7/16 Type

Impedance Operating Voltage Frequency Range Shielding Effectiveness Inner Contact Resistance Outer Contact Resistance Intermodulation Insulation Resistance Dielectric Withstanding Voltage Insertion Loss VSWR 0.8 ~ 1.0GHz 1.7 ~ 2.5GHz Inner Conductor Pin Inner Conductor Socket Insulator Body & Outer Conductor Gasket Temperature Range Durability

50 Ω 1500 V

≤18.0 GHz ≥115 dB ≤0.8 mΩ

≤0.25 mΩ ≤-155 dBc ≥5000 MΩ

2500 V ≤0.1 dB ≤1.08 ≤1.10

Brass/Silver Plating Tin Bronze /Silver Plating PTFE or TPX Brass/Trimetal plating Silicon Rubber

-65 ºC ~ +165ºC ≥500 cycle

50 Ω 2700 V

≤7.5 GHz ≥115 dB ≤0.4 mΩ ≤0.2 mΩ

≤-155 dBc ≥10000 MΩ

3000 V ≤0.08 dB

≤1.08 ≤1.10

Brass/Silver Plating Tin Bronze/Silver Plating PTFE or TPX Brass/Trimetal Plating Silicon Rubber

-65 ºC ~ +165 ºC ≥500 cycle

Page 34: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

TABLE CONNECTORS SELECTION GUIDE

NF-7/8”L NM-1/2”H DINF-1/2”L DINM-1/2”H

Leaky Radiating CABLE Cable type leaky 1/2”R leaky 7/8”R leaky 1-1/4”R leaky 1-5/8”R

Connector code

DINM-1/2”R DINM-7/8”R DINM-1-1/4”R DINM-1-5/8”R

DINF-1/2”R DINF-7/8”R DINF-1-1/4”R DINF-1-5/8”R

NM-1/2”R NM-7/8”R NM-1-1/4”R NM-1-5/8”R

NF-1/2”R NF-7/8”R NF-1-1/4”R NF-1-5/8”R

Model Ref. Description

DINM-1/2”R CCF12RDM Connector Radiating DINM-1/2”R std Trimetal plating Straight Male

DINF-1/2”R CCF12RDF Connector Radiating DINF-1/2”R std Trimetal plating Straight Male

NM-1/2”R CCF12RNM Connector Radiating NM-1/2”R std Trimetal plating Straight Male

NF-1/2”R CCF12RNF Connector Radiating NF-1/2”R std Trimetal plating Straight Male

DINM-7/8”R CCF78RDM Connector Radiating DINM-7/8”R std Trimetal plating Straight Male

DINF-7/8”R CCF78RDF Connector Radiating DINF-7/8”Rstd Trimetal plating Straight Male

NM-7/8”R CCF78RNM Connector Radiating NM-7/8”R std Trimetal plating Straight Male

NF-7/8”R CCF78RNF Connector Radiating NF-7/8”R std Trimetal plating Straight Male

DINM-1-1/4”R CCF114RDM Connector Radiating DINM-1-1/4”R std Trimetal plating Straight Male

DINF-1-1/4”R CCF114RDF Connector Radiating DINF-1-1/4”R std Trimetal plating Straight Male

NM-1-1/4”R CCF114RNM Connector Radiating NM-1-1/4”R std Trimetal plating Straight Male

NF-1-1/4”R CCF114RNF Connector Radiating NF-1-1/4”R std Trimetal plating Straight Male

DINM-1-5/8”R CCF158RDM Connector Radiating DINM-1-5/8”R std Trimetal plating Straight Male

DINF-1-5/8”R CCF158RDF Connector Radiating DINF-1-5/8”R std Trimetal plating Straight Male

NM-1-5/8”R CCF158RNM Connector Radiating NM-1-5/8”R std Trimetal plating Straight Male

NF-1-5/8”R CCF158RNF Connector Radiating NF-1-5/8”R std Trimetal plating Straight Male

DIATING COAXIAL CABLE

Page 35: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Radiating Clamp – Premium

Radiating Clamps plastic and metalic systems System Premium for 1/2", 5/8”, 7/8”, 1-1/4” and 1-5/8”

FEATURES and BENEFITS

• SLX cable clamps are used for the installation of radiating cables in tunnels.

• SLX clamps may be installed with or without spacers. • SLX cable clamps are designed with two clips coupled to a

central snap-in cap. • The two clips allow a quick insertion of the cable, while

the central snap-in cap assures the final locking. • An additional locking screw is joint.

TECHNICAL FEATURES SPECIFICATIONS

Plastic System Premium

Are used to fasten radiating cables in tunnels, underground and indoor in general. Additional AISI 302 security screw

PA6V0, black colour, self extinguishing, halogen free (according to UL94 - V0).

Operating temperature : - 40°C + 125°C

Single-hand installation – a matter of course with CLIC, place the cable, apply slight pressure and the clamp locks itself with a sharp clic.

• Automatic locking by pushing cable into clamp • Unlocks with screwdriver

Page 36: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Radiating Clamp – Premium

TECHNICAL FEATURES SPECIFICATIONS

Metalic System Premium

SLXM - Square Collar for Radiating Cables

Complete with rigid calibrated saddles The SLXM square collar is formed by two shells joined by M6 screws and calibrated saddles. It is recommended in combination with SLXMM clamps for radiating cables.

Whether inserted at a suitable distance (10-15 m) among SLX clamps, it prevents radiating cable lines from falling down, in case of fire.

Material:

Collar: AISI 304 stainless steel Saddles: Glass reinf. P.A., black colour

SLXCM - Around Collar for Radiating Cables

The SLXCM round collar has been especially designed for quick installation of HF and DC cables as well as for pipes.

It is recommended in combination with SLX clamps for radiating cables. Whether inserted at a suitable distance (10-15 m) among SLX clamps, it prevents radiating cable lines from falling down, in case of fire.

Page 37: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Radiating Clamp – Premium

TABLE SELECTION GUIDE

Base Plastic Spacer

P.A. Fiberglass Spacer P.A./fiberglass spacer to keep SLXR cable clamps separated from the wall. Fixing with P.A. plug R8/SP. Material: PA6V0, self-extinguishing, halogen free (according to UL94 - V0).

Code H Description pack gr

SLX2050

50 base spacer 50 mm 50 14

SLX2080 80 base spacer 80 mm 50 22

Plastic System

Code Model Cables For cables øD L H h1 gr

SLX0012 SLXR 1/2’’ 15-18 46 36,5 13 20

SLX0058 SLXR 5/8” 20-23 46 41 13 22

SLX0078 SLXR 7/8” 26-30 46 45 13 26

SLX0114 SLXR 1.1/4” 38-41 66 65 17 68

SLX0158 SLXR 1.5/8” 47-51 81,5 80 19 116

Metalic System

Code Article/description ØD L H pz gr

SLX0012M Clamp Metalic System Premium 1/2’’ 16 - 17 16 - 17 22 36 50 90

SLX0058M Clamp Metalic System Premium 5/8” 21 - 23 21 - 23 22 36 50 86

SLX0078M Clamp Metalic System Premium 7/8” 27 - 28 27 - 28 34 48 50 114

SLX0114M Clamp Metalic System Premium 1.1/4” 39 - 40 39 - 40 34 48 50 110

SLX0158M Clamp Metalic System Premium 1.5/8” 50 - 52 50 - 52 34 48 50 108

Code Article Cables ØD H pz

SLXCM0020 Clamp Metalic System Premium 1/2’’ Ø 13 ÷ 20 1/2” Ø 13 ÷ 20 44 20

SLXCM0030 Clamp Metalic System Premium 7/8” Ø 22 ÷ 30 7/8” Ø 22 ÷ 30 55 20

SLXCM0040 Clamp Metalic System Premium 1.1/4” Ø 30 ÷ 40 1.1/4” Ø 30 ÷ 40 67 20

SLXCM0050 Clamp Metalic System Premium 1.5/8” Ø 40 ÷ 52 1.5/8” Ø 40 ÷ 52 79 20

Code L Description pack

SLX1050 50 Spacers with M8x16 screw and washer RPI 8/16 50

SLX1075

75 Spacers with M8x16 screw and washer RPI 8/16 50

SLX1010 100 Spacers with M8x16 screw and washer RPI 8/16 50

Page 38: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Radiating Clamp – Premium

EXAMPLES OF INSTALLATION

Base Plastic Spacer

SLX Installation example Installation of Radiating Cable in Tunnel Installation by using SLX cable clamps. SLX cable clamps are fixed to the wall by a mechanical or chemical fastener, directly or through spacers The installation is quick and safe thanks to an elastic provisional pre-fixing of the cable. The final closure is assured by the cap of the SLX cable clamp

SLX Installation example Installation of Radiating Cable on Cable Trail Fixing of SLX clamp on linear guide rails with spacers SLX10 or SLX24

Page 39: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Radiating Clamp – Standard

Radiating Clamp System Clic clamps are used for installing radiating cables in gal- leries and tunnels with or without spacers. The installation is very simple and quick. Stainless Stell Cable Clamps are used to provide Fire Resistant installations of Radiating Cables in galleries or tunnels with or without spacers. The installation is very simple and quick. To limit the interference that could be caused by Metal Objects on the RF field generated by a Radiating Cable, only every 10th fixing should be metallic.

Radiating Clamps plastic and metalic systems 1/2" | 5/8” | 7/8” | 1-1/4” | 1-5/8”

FEATURES and BENEFITS

• Lock with 1 or 2 locking positions • Automatic locking by pushing cable into clamp, reusable • Unlocks with screwdriver • Pivoted hangers allow installation down to -25°C • Slot design allows installation correction of up to 4.5 mm • Slot for insertion of flange for rod and stud mounting

TECHNICAL FEATURES SPECIFICATIONS

Plastic System

Material Pure Polyamide, halogen free, fire class UL94HB, UV-resistant

Environmental

Operating Temperature °C - 25 to +110

Installation Temperature °C -10 to +60

Color standard black

Metalic System

Material Metalic Clamp Fire Resistant

Environmental

Operating Temperature °C - 50 to +400

Color standard black and metalic

Page 40: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Radiating Clamp – Standard

TABLE SELECTION GUIDE

Plastic System

Clic type for 1/2” for 5/8” for 7/8” for 1-1/4” for 1-5/8”

Clamping mm 14.3 - 16.8 19.5 - 22.0 24.6 - 27.8 35.5 - 39.5 46.5 - 50.5

Max. load N 600 700 850 1100 1300

Part reference SLX9415AN SLX9420AN SLX9426AN SLX9435AN SLX946AN

Metalic System

Clic type for 1/2” for 5/8” for 7/8” for 1-1/4” for 1-5/8”

Clamping mm 15 22 27 38 49

Max. load N 600 700 850 1100 1300

Part reference SLX9XCLIP15 SLX9XCLIP22 SLX9XCLIP27 SLX9XCLIP35 SLX9XCLIP46

SPACERS and ACCESSORIES

Click Calmp

Reference Description

SLX94CSCRM Round base spacer 80 mm

SLX94CSCQM Round base spacer 80 mm

SLX9X481207981 Wood screw 4.8 x 120mm

SLX9X895912 DIN 912 M8x95mm, hex socket head

SLX96FX Nylon plug for wood screw diameter 6 mm

SLX9X8SFA Stainless steel plug M8

rmv
Tachado
Page 41: Catalogo Cables Radiantes, Leaky Radiating Cables

Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.

See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com

RADIATING COAXIAL CABLE

Leaky Cable

Regulatory Compliance/Certifications

ISO 9001:2008 ISO 14001:2004 OHSAS 18001

RoHS 2011/65/EU RoHS Compliant Designed, manufactured and/or distributed under quality management system

Silexstr Radiating Cable ® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas. Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Coupling & Radiating Cable is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.

Page 42: Catalogo Cables Radiantes, Leaky Radiating Cables

Radiating and Coupling Cable Systems Frequency TETRA / TETRAPOL TDMA / CDMA 800 GSM 900 DCS / GSM 1800 PCN / PCS 1900 UMTS 2200 W-CDMA 2200 DECT 900 GSM-R WLAN 2400 WLAN 5700 LTE

Cables Together the cables and the connectors from Silex are an unbeatable match that optimises the entire system performance:

• Low attenuation • Excellent field strength with low coupling loss • Increased amplifier spacing due to very low longitudinal attenuation • Simple connector installation • Quick cable installation • Halogen-free and fire retardant jacketing

Page 43: Catalogo Cables Radiantes, Leaky Radiating Cables

.

Silex Global Spain, S.L. San Erasmo, 31 Nave 8 28021 - Madrid (Spain) Tel.: + 34 915 05 67 76 E-Mail: [email protected] Web: www.silexst.com Web: www.silexfiber.com Certified Products: ISO / EN / IEC Ordering No. Info32543SLink/WERE/09-2014 pA 1SFSD34 © 09.2015 Silexst Production & Powered By Silex Global Spain

All specifications are subject to change. See www.silexst.com for the most current information. Revised: September 06, 2015

Silex Global Spain, S.L. | The information contained in this document is accurate to the best of our knowledge and representative of the part described herein. It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements. Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal.

[email protected] – www.silexst.com ©2014 Silexst All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of Silexst