Catalog Implantium

download Catalog Implantium

of 128

Transcript of Catalog Implantium

  • 7/26/2019 Catalog Implantium

    1/128

    Unit:mm, Scale 1: 1.5 / mm

    SuperLine & Implantium Product Catalog 1

    SuperLine & ImplantiumProduct/Manual Catalog

  • 7/26/2019 Catalog Implantium

    2/128

    SuperLine & Implantium

  • 7/26/2019 Catalog Implantium

    3/128

    IntroductionS.L.A. Surface 04

    SuperLine Characteristics 06

    SuperLine Color Coding by Diameter 08SuperLine Fixture 09

    IMPLANTIUM Characteristics 12

    IMPLANTIUM Color Coding by Diameter 14

    IMPLANTIUM Fixture 15

    Surgical ComponentsCover Screw 16

    Healing Abutment 17

    Prosthetic Procedure 1Dual / Combi Abutment - Abutment Level Impression 18

    Combi Abutment 19

    Dual Abutment [Hex] 20

    Dual Abutment [Non-hex] 21

    Abutment Level Impression Components 22

    Restorative Kit 23

    Prosthetic Procedure 2Dual / Custom / Dual Milling / Angled / Direct-Casting /

    Metal-Casting / Temporary (Plastic & T i) Abutment

    - Fixture Level Impression 24

    Fixture Level Impression Components 25

    Custom Abutment 27

    Dual Milling Abutment [Ti-G4] 28

    Dual Milling Abutment [Ti-G2] 30

    Angled Abutment[Ti-G4 / 15] 32

    Angled Abutment[Ti-G4 / 25] 33

    Angled Abutment[Ti-G2 / 15] 34

    Angled Abutment[Ti-G2 / 25] 35

    Direct-Casting Abutment 36

    Metal-Casting Abutment 36

    Temporary Abutment 37

    Prosthetic Procedure 3Screw Abutment -Abutment Level Impression 38

    Screw Abutment 39Angled Screw Abutment 40

    Screw Abutment Impression Components 41

    Prosthetic Procedure 4Overdenture Procedure

    - Positioner / Mini Ball / Magnetic Attachment 44

    Positioner 45

    Mini Ball Attachment 47

    Magnetic Attachment (Dome Type) 48

    Magnetic Attachment (Flat Type) 49

    InstrumentsSurgical Kit (Full) 50

    Surgical Kit (Standard) 51

    Surgical Kit (Short Implant) 52

    Drill Stopper Kit 53

    Drill 54

    Stopper 58

    Instrument 59

    DASK 62

    Sinus Bur Kit / Sinus Kit 63

    DASK / Sinus Bur Kit / Sinus Kit 64

    Osteotome Kit 65

    Trephine Kit 66

    Prosthetic Kit 67

    Planning Kit 68

    Prosthetic and Laboratory Instrument 69

    Help Kit 71

    Surgical Manual 72Prosthesis Manual 82

    Contents

  • 7/26/2019 Catalog Implantium

    4/128

    SuperLine & Implantium Product Catalog04

    S.L.A. SurfaceS.L.A. (Sandblasting with large grit and acid etching)

    Higher bone-to-implant contact. Faster bone formation on the surface.

    In vivo test

  • 7/26/2019 Catalog Implantium

    5/128

  • 7/26/2019 Catalog Implantium

    6/128

    SuperLine & Implantium Product Catalog06

    SuperLine Characteristics

    "Immediate Implantation with Excellent Bone Response"

    Higher stabilization in extraction socket

    Early loading in upper posterior

    Harmony with anatomy

    Sharp & fast insertion

    A

    D

    B

    C

    Platform

    Body

    Abutment

    G/H

    FixtureLength

    Selection Guideline

    Ideal emergence profile for each tooth

    Bevel

    Abutment

    AbutmentHeight

  • 7/26/2019 Catalog Implantium

    7/128

    SuperLine & Implantium Product Catalog 07

    SuperLine Characteristics

    B

    The conical hex connection between implant and

    abutment interface ensures hermetic sealing.

    The biologic connection distributes the load to the

    fixture evenly. Therefore it helps minimize

    micro-movement and marginal bone loss.

    All implant diameters share the same internal hex.

    Biological Connection C-1

    Increased thread height helps increase the initial stability.

    Double thread may decrease the chair time of implantation

    Double Thread & Thread Height

    D Prosthesis

    One abutment screw fits all abutments and fixture platforms.

    Single abutment connection is used for all implant diameters.

    One hex screw driver fits all abutment screws

    The greater distance between

    the threads may promote early

    osseointegration

    C-2 Osseointegration

    Dual Milling Angled Direct Screw

    A Tapered Design

    Tapered load distribution may achieve excellent

    bone response.

    Tapered design may harmonize with surrounding

    bone anatomically.

    The large surface area helps provide excellent

    initial stability with sinus augmentation.

  • 7/26/2019 Catalog Implantium

    8/128

    SuperLine & Implantium Product Catalog08

    SuperLineColor Coding by Diameter

    Color Coding by Diameter

    Cap Color

    Fixture

    SuperLine

    (Mount Free)

    Fixture

    Platform

    Diameter

    (Unit: mm)

    Platform

    Cover screw is not included.

    L : 7

    Fixture

    Bevel

    Height

    Fixture

    Body

    Diameter

    Body

    Bevel

    Yellow Green Blue Red Orange Violet

    3.7 4.0 4.5 5.0 6.0 7.0

    3.6 4.0 4.5 5.0 5.0 5.8

    1.5 1.5 1.5 1.5 1.5 1.5

    0 0.1 0.3 0.4 0.7 1.0

    L : 8, 10,

    12, 14

    Fixture

    Bevel

    Height

    Bevel

  • 7/26/2019 Catalog Implantium

    9/128

    SuperLine & Implantium Product Catalog 09

    SuperLine FixtureUnit: mm, Scale 1 : 1.5 / mm

    3.7

    L

    L

    3.6

    4.0

    4.0

    Platform5.0 | Body 5.0

    Platform4.5 | Body 4.508 10 12 14

    4.5

    L

    L

    4.5

    5.0

    5.0

    L Art. No.

    7 FXS 45 07

    8 FXS 45 08

    10 FXS 45 10

    12 FXS 45 12

    14 FXS 45 14

    L Art. No.

    7 FXS 50 07

    8 FXS 50 08

    10 FXS 50 10

    12 FXS 50 12

    14 FXS 50 14

    070.3 0.3 0.3 0.3

    1.5

    08 10 12 14070.4 0.4 0.4 0.41.5

    08 10 12 14070.1 0.1 0.1 0.1

    08 10 12 1407

    Platform4.0 | Body 4.0

    L Art. No.

    7 FXS 40 07

    8 FXS 40 08

    10 FXS 40 10

    12 FXS 40 12

    14 FXS 40 14

    Platform3.7 | Body 3.6

    L Art. No.

    7 FXS 36 07

    8 FXS 36 08

    10 FXS 36 10

    12 FXS 36 12

    14 FXS 36 14

    Note: 1) To prevent damage to the Implant driver or fixture, do not over torque during fixture insertion

    1.5

    1.5

  • 7/26/2019 Catalog Implantium

    10/128

    SuperLine & Implantium Product Catalog10

    SuperLine FixtureUnit: mm, Scale 1 : 1.5 / mm

    1.0

    Platform7.0 | Body 5.8 7.0

    L

    5.8

    Platform6.0 | Body 5.0

    L

    5.0

    6.008 10 1207

    1.5

    08 10 12071.5

    0.70.70.7

    1.01.0

    L Art. No.

    7 FXS 60 07

    8 FXS 60 08

    10 FXS 60 10

    12 FXS 60 12

    L Art. No.

    7 FXS 70 07

    8 FXS 70 08

    10 FXS 70 10

    12 FXS 70 12

  • 7/26/2019 Catalog Implantium

    11/128

  • 7/26/2019 Catalog Implantium

    12/128

    SuperLine & Implantium Product Catalog12

    Implantium Characteristics

    Selection Guideline

    Ideal emergence profile for each tooth

    E

    G

    A

    D

    B

    C

    F

    Platform

    Body

    Final Drill

    Neck

    Bevel

    Abutment

    G/H

    AbutmentHeight

    FixtureLength

    3

    Maximum

    Reduction Line

    Abutment

  • 7/26/2019 Catalog Implantium

    13/128

    SuperLine & Implantium Product Catalog 13

    Implantium Characteristics

    G Maintained Compatibility

    Prosthetic componentsand Surgical Kit 100%

    compatible with the existing ImplantiumImplant System

    C Biological Connection

    The conical hex connection between implant and abutment

    interface ensures hermetic sealing.

    The biologic connection distributes the load to the fixture

    evenly. Therefore it helps minimize micro-movement and

    marginal bone loss.

    All implant diameters share the same internal hex.

    Quadruple & Double thread Design

    Chair time decreased through faster fixture placement

    E

    F Optimal Fixation Threads

    Greater advantage for Immediate and Early Loading

    Enhanced initial stability through longer and sharper

    threading

    Biological Thread

    Thread platform design creates excellent bone to

    implant contact.

    Threads engage and penetrate bone with ease.

    D

    Longer and Upgraded Cutting

    EdgeA

    Improved self-tapping ability

    Allows more control over the depth of

    fixture placement

    Alleviates the occurrence of over-torque

    during placement in dense bone

    Bacteria Resistant Bevel

    The tapered bevel platform design may make bone

    profiling unnecessary at 1st, 2nd surgery.

    B

  • 7/26/2019 Catalog Implantium

    14/128

    SuperLine & Implantium Product Catalog14

    Implantium Color Coding by Diameter

    Color Coding by Diameter

    Cap Color

    Fixture

    Implantium

    (Mount Free)

    Fixture

    Platform

    Diameter

    (Unit: mm)

    Platform

    Cover screw is not included.

    Fixture

    Body

    Diameter

    Body

    Yellow Green Blue Red

    3.6 4.0 4.5 5.0

    3.6 4.0 4.5 5.0

    Fixture

    Bevel

    Height

    Bevel

    0.15 0.11 0.25 0.4

  • 7/26/2019 Catalog Implantium

    15/128

    SuperLine & Implantium Product Catalog 15

    Implantium FixtureUnit: mm, Scale 1 : 1.5 / mm

    08 10 12 143.6

    L

    3.6

    Platform3.6 | Body 3.6

    L Art. No.

    8 FXI 36 08

    10 FXI 36 10

    12 FXI 36 12

    14 FXI 36 14

    4.0

    L

    4.0

    4.5

    L

    4.5

    5.0

    L

    5.0

    08 10 12 14

    Platform4.0 | Body 4.0

    L Art. No.

    8 FXI 40 08

    10 FXI 40 10

    12 FXI 40 12

    14 FXI 40 14

    08 10 12 14

    Platform4.5 | Body 4.5

    L Art. No.

    8 FXI 45 08

    10 FXI 45 10

    12 FXI 45 12

    14 FXI 45 14

    08 10 12 14

    Platform5.0 | Body 5.0

    L Art. No.

    8 FXI 50 08

    10 FXI 50 10

    12 FXI 50 12

    14 FXI 50 14

    Note: 1) To prevent damage to the Implant driver or fixture, do not over torque during fixture insertion

  • 7/26/2019 Catalog Implantium

    16/128

    SuperLine & Implantium Product Catalog16

    Healing Abutment

    Cover ScrewUnit: mm, Scale 1 : 1.5 / mm

    Unit: mm, Scale 1 : 1.5 / mm

    Hex driver: Use no more than 5Ncm torque when screwing a cover screw to a fixture.

    If hex is worn, slot on the head of the product can be used to rotate it.

    Color: Green 3.6

    Art. No. CS36

    CS36 andFXS4510

    4.5

    3.6

    Single use only

    Single use only4.5

    G/H 3.0H 5.0

    HAB453050L andFXS4510

  • 7/26/2019 Catalog Implantium

    17/128

    SuperLine & Implantium Product Catalog 17

    3.8

    2.0

    Hex driver: Use no more than 10Ncm of torque when screwing a healing abutment to a fixture.

    If hex is worn, slot on the head of the product can be used to rotate it.

    Diameter 4.0

    Diameter 3.3 / 3.8

    G/H H Art. No.

    2.0 2.0 HAB 40 20 20 L

    2.0 3.5 HAB 40 20 35 L

    3.0 5.0 HAB 40 30 50 L

    4.0 7.0 HAB 40 40 70 L

    G/H Art. No.

    3.5 GBHAB 33 35

    0.5 GBHAB 38 05

    2.0 GBHAB 38 20

    6.56.5

    6.5

    3.52.0

    5.03.0

    7.04.0

    4.04.0 4.0

    3.52.0

    5.03.0

    7.04.0

    4.54.5

    4.5

    3.5 5.0

    3.0

    7.04.0

    5.55.5

    5.5

    3.52.0

    5.03.0

    7.04.0

    7.5

    5.03.0

    4.0

    2.0

    3.5

    0.52.0

    4.5

    5.5

    6.5

    Diameter 4.5

    G/H H Art. No.

    2.0 2.0 HAB 45 20 20 L

    2.0 3.5 HAB 45 20 35 L

    3.0 5.0 HAB 45 30 50 L

    4.0 7.0 HAB 45 40 70 L

    Diameter 5.5

    G/H H Art. No.

    2.0 2.0 HAB 55 20 20 L

    2.0 3.5 HAB 55 20 35 L

    3.0 5.0 HAB 55 30 50 L

    4.0 7.0 HAB 55 40 70 L

    Diameter 6.5

    G/H H Art. No.

    2.0 2.0 HAB 65 20 20 L

    2.0 3.5 HAB 65 20 35 L

    3.0 5.0 HAB 65 30 50 L

    4.0 7.0 HAB 65 40 70 L

    Diameter 7.5 / 8.5 / 9.5

    G/H H Art. No.

    3.0 5.0 HAB 75 30 50 L

    3.0 5.0 HAB 85 30 50 L

    3.0 5.0 HAB 95 30 50 L

    8.5

    5.03.0

    9.5

    5.03.0

    2.02.0

    2.0

    2.0

    3.8

  • 7/26/2019 Catalog Implantium

    18/128

    SuperLine & Implantium Product Catalog18

    Prosthetic Procedure 1

    Dual / Combi Abutment

    Closed Tray Technique

    Cemented Restoration

    Modification

    Abutment Level Impression

    Burn-out Cylinder

    Impression Coping

    Transfer (Snap on)4.5 / 5.5 / 6.5

    Page22

    Analog

    Long 4.5 / 5.5 / 6.5

    Page22

    Analog

    Short 4.5 / 5.5 / 6.5

    Page22

    Bridge

    Rotational

    4.5 / 5.5 / 6.5

    Page22

    Single

    Non-rotational

    4.5 / 5.5 / 6.5

    Page22

    Dual Abutment

    Hex / Non-hex 4.5 / 5.5 / 6.5

    Page20, 21

    Combi Abutment

    4.5 / 5.5 / 6.5

    Page19

    Impression Technique and Restoration Selection

  • 7/26/2019 Catalog Implantium

    19/128

    SuperLine & Implantium Product Catalog 19

    Combi AbutmentUnit: mm, Scale 1 : 1 / mm

    G/H 3.5

    5.5

    5.5

    1.5

    CAB5535L andFXS4510

    G/H 3.5

    4.0

    5.5

    CAB5535SL andFXS4510

    1.0 1.5 2.5 3.5 4.5 5.5

    1.5 2.5 3.5 4.5 5.5

    G/H Art. No. Art. No

    1.0 CAB 45 10 SL CAB 45 10 L

    1.5 CAB 45 15 SL CAB 45 15 L

    2.5 CAB 45 25 SL CAB 45 25 L

    3.5 CAB 45 35 SL CAB 45 35 L 4.5 CAB 45 45 SL CAB 45 45 L

    5.5 CAB 45 55 SL CAB 45 55 L

    Diameter 4.5

    Type

    Short

    Type

    Long

    G/H Art. No. Art. No

    1.5 CAB 55 15 SL CAB 55 15 L

    2.5 CAB 55 25 SL CAB 55 25 L

    3.5 CAB 55 35 SL CAB 55 35 L

    4.5 CAB 55 45 SL CAB 55 45 L

    5.5 CAB 55 55 SL CAB 55 55 L

    Diameter 5.5

    Type

    Short

    Type

    Long

    1.5 2.5 3.5 4.5 5.5

    G/H Art. No. Art. No

    1.5 CAB 65 15 SL CAB 65 15 L

    2.5 CAB 65 25 SL CAB 65 25 L

    3.5 CAB 65 35 SL CAB 65 35 L

    4.5 CAB 65 45 SL CAB 65 45 L

    5.5 CAB 65 55 SL CAB 65 55 L

    Diameter 6.5

    Type

    Short

    Type

    Long

    G/H

    G/H

    G/H

    5.5

    4.0

    G/H

    G/H

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the combi abutment with fixture.

    5.5

    4.0

    G/H

    G/H

    5.5

    4.0

    G/H

    G/H

  • 7/26/2019 Catalog Implantium

    20/128

    SuperLine & Implantium Product Catalog20

    Dual Abutment [Hex]Unit: mm, Scale 1 : 1.5 / mm

    G/H 3.5

    5.5

    5.5

    1.5

    G/H Art. No.

    1.0 DAB 45 10 HL

    1.5 DAB 45 15 HL

    2.5 DAB 45 25 HL 3.5 DAB 45 35 HL

    4.5 DAB 45 45 HL

    5.5 DAB 45 55 HL

    1.0 1.5 2.5 3.5 4.5 5.5

    Diameter4.5 | Hex

    G/H Art. No.

    1.5 DAB 55 15 HL

    2.5 DAB 55 25 HL

    3.5 DAB 55 35 HL

    4.5 DAB 55 45 HL

    5.5 DAB 55 55 HL

    1.5 2.5 3.5 4.5 5.5

    Diameter5.5 | Hex

    DAB5535HL andFXS4510

    G/H Art. No.

    1.5 DAB 65 15 HL

    2.5 DAB 65 25 HL

    3.5 DAB 65 35 HL

    4.5 DAB 65 45 HL

    5.5 DAB 65 55 HL

    1.5 2.5 3.5 4.5 5.5

    Diameter6.5 | Hex

    G/H

    G/H

    G/H

    G/H

    5.5

    G/H

    5.5

    G/H

    5.5

    Abutment screw is included.

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual abutment with fixture.

  • 7/26/2019 Catalog Implantium

    21/128

    SuperLine & Implantium Product Catalog 21

    Dual Abutment [Non-hex]Unit: mm, Scale 1 : 1.5 / mm

    G/H 3.5

    5.5

    5.5

    1.5

    G/H Art. No.

    1.0 DAB 45 10 NL

    1.5 DAB 45 15 NL

    2.5 DAB 45 25 NL 3.5 DAB 45 35 NL

    4.5 DAB 45 45 NL

    5.5 DAB 45 55 NL

    1.0 1.5 2.5 3.5 4.5 5.5

    Diameter 4.5 | Non-hex

    G/H Art. No.

    1.5 DAB 55 15 NL

    2.5 DAB 55 25 NL

    3.5 DAB 55 35 NL

    4.5 DAB 55 45 NL

    5.5 DAB 55 55 NL

    1.5 2.5 3.5 4.5 5.5

    Diameter 5.5 | Non-hex

    DAB5535NL andFXS4510

    G/H Art. No.

    1.5 DAB 65 15 NL

    2.5 DAB 65 25 NL

    3.5 DAB 65 35 NL

    4.5 DAB 65 45 NL

    5.5 DAB 65 55 NL

    1.5 2.5 3.5 4.5 5.5

    Diameter 6.5 | Non-hex

    G/H

    G/H

    G/H

    G/H

    5.5

    G/H

    5.5

    G/H

    5.5

    Abutment screw is included.

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual abutment with fixture.

  • 7/26/2019 Catalog Implantium

    22/128

    SuperLine & Implantium Product Catalog22

    Abutment Level Impression Components

    Unit: mm, Scale 1 : 1 / mm

    4.5 5.5 6.5 Diameter Art. No.

    4.5 CIC 45 L

    5.5 CIC 55 L

    6.5 CIC 65 L

    Impression Coping

    Comfort Cap | Snap on

    4.5 5.5 6.5

    4.8

    Type Diameter Art. No.

    4.5 CCC 45 CS

    Short 5.5 CCC 55 CS

    6.5 CCC 65 CS

    4.5 CCC 45 C

    Long 5.5 CCC 55 C

    6.5 CCC 65 C

    6.8

    10.4

    Lab Analog

    Type Diameter Art. No.

    4.5 CAN 45 SL

    Short 5.5 CAN 55 SL

    6.5 CAN 65 SL

    4.5 CAN 45 LL

    Long 5.5 CAN 55 LL

    6.5 CAN 65 LL

    Burn-out Cylinder

    Type Diameter Art. No.

    4.5 CBC 45 SL

    Single 5.5 CBC 55 SL

    6.5 CBC 65 SL

    4.5 CBC 45 BL

    Bridge 5.5 CBC 55 BL

    6.5 CBC 65 BL

    4.5 5.5 6.5

    4.0

    12.0

    5.5

    12.0

    4.5 5.5 6.5

    12.8

    12.8

  • 7/26/2019 Catalog Implantium

    23/128

    SuperLine & Implantium Product Catalog 23

    Restorative Kit

    Lab. Components

    Comfort Cap Impression Coping Analog Burn-out Cylinder

    XSDAB 45 S CCC 45 CSCIC 45L

    CAN 45 SLCBC 45 SL CBC 45 BL

    XSDAB 45 CCC 45 C CAN 45 LL

    XSDAB 55 S CCC 55 CSCIC 55L

    CAN55 SLCBC 55 SL CBC 55 BL

    XSDAB 55 CCC 55 C CAN 55 LL

    XSDAB 65 S CCC 65 CSCIC 65L

    CAN 65 SLCBC 65 SL CBC 65 BL

    XSDAB 65 CCC 65 C CAN 65 LL

    Combi & Dual Abutment

    Art. No

  • 7/26/2019 Catalog Implantium

    24/128

    SuperLine & Implantium Product Catalog24

    Prosthetic Procedure 2

    Dual / Custom / Dual Milling / Angled / Direct-Casting /

    Metal-Casting / Temporary (Plastic & Ti) Abutment

    Fixture Level Impression

    Impression Coping Transfer

    Closedtray technique (Simple case)

    4.0 / 4.5 / 5.5 / 6.5

    Page26

    Hex Non-hex

    Screw-Retained

    Restoration

    Modification

    Modification

    DualAbutment

    Hex / Non-hex

    4.5 / 5.5 / 6.5

    Page20, 21

    CustomAbutment

    Hex / Non-hex

    4.5 / 5.5

    Page27

    Dual MillingAbutmentHex / Non-hex

    4.0 / 4.5

    5.5 / 6.5 / 7.5

    Page28, 30

    Analog

    DAN 34 / DANSE

    Page25, 26

    Impression Technique and Restoration Selection

    Cemented

    Restoration

    AngledAbutmentHex / Non-hex

    15 / 25

    4.5 / 5.5

    Page32, 33, 34, 35

    Direct-CastingAbutment

    Hex / Non-hex

    4.5

    Page36

    Metal-CastingAbutment

    Hex / Non-hex

    4.5

    Page36

    TemporaryAbutment

    Hex / Non-hex

    4.5 / 5.5 / 6.5

    Page37

    Hex Non-hex

    Impression Coping Pick-up

    Opentray technique (Complicated case)

    4.0 / 4.5 / 5.5 / 6.5

    Page25

  • 7/26/2019 Catalog Implantium

    25/128

    SuperLine & Implantium Product Catalog 25

    Unit: mm, Scale 1 : 1.5 / mm

    Fixture Level Impression Components

    Impression coping screw is included with Impression coping.

    Size Art. No.

    Short DPS 11

    Long DPS 15

    Impression Coping Pick-up Screw

    Long

    Short

    Impression Coping Pick-up 4.0

    Size Type Art. No.

    Short Hex DPU 4011 HL

    Short Non-hex DPU 4011 NL

    Long Hex DPU 4015 HL

    Long Non-hex DPU 4015 NL

    4.0 4.0 4.0 4.0

    Impression Coping Pick-up 4.5

    Size Type Art. No.

    Short Hex DPU 4511 HL

    Short Non-hex DPU 4511 NL

    Long Hex DPU 4515 HL

    Long Non-hex DPU 4515 NL

    Impression Coping Pick-up 5.5

    Size Type Art. No.

    Short Hex DPU 5511 HL

    Short Non-hex DPU 5511 NL

    Long Hex DPU 5515 HL

    Long Non-hex DPU 5515 NL

    Impression Coping Pick-up 6.5

    Size Type Art. No.

    Short Hex DPU 6511 HL

    Short Non-hex DPU 6511 NL

    Long Hex DPU 6515 HL

    Long Non-hex DPU 6515 NL

    Hex Non-hex Hex Non-hex

    17.0 17.0 21.0 21.0

    4.5 4.5 4.5 4.5

    Hex Non-hex Hex Non-hex

    17.0 17.0 21.0 21.0

    5.5 5.5 5.5 5.5

    Hex Non-hex Hex Non-hex

    17.0 17.0 21.0 21.0

    6.5 6.5 6.5 6.5

    Hex Non-hex Hex Non-hex

    17.0 17.0 21.0 21.0

    23.0

    27.0

    12.0

    4.0

    12.0

    4.5

    Application (Body) Art. No.

    3.4(Only Implantium) DAN 34

    3.4 / 3.8 / 4.3 / 4.8 / 5.8 DANSE

    Analog

  • 7/26/2019 Catalog Implantium

    26/128

    SuperLine & Implantium Product Catalog26

    Unit: mm, Scale 1 : 1.5 / mm

    Fixture Level Impression Components

    Impression coping screw is included with Impression coping.

    Size Art. No.

    Short DTS 11

    Long DTS 15

    Impression Coping Transfer Screw

    Impression Coping Transfer 4.0

    Size Type Art. No.

    Short Hex DTF 4011 HL

    Short Non-hex DTF 4011 NL

    Long Hex DTF 4015 HL

    Long Non-hex DTF 4015 NL

    Impression Coping Transfer 4.5

    Size Type Art. No.

    Short Hex DTF 4511 HL

    Short Non-hex DTF 4511 NL

    Long Hex DTF 4515 HL

    Long Non-hex DTF 4515 NL

    Impression Coping Transfer 5.5

    Size Type Art. No.

    Short Hex DTF 5511 HL

    Short Non-hex DTF 5511 NL

    Long Hex DTF 5515 HL

    Long Non-hex DTF 5515 NL

    Impression Coping Transfer 6.5

    Size Type Art. No.

    Short Hex DTF 6511 HL

    Short Non-hex DTF 6511 NL

    Long Hex DTF 6515 HL

    Long Non-hex DTF 6515 NL

    4.0 4.0 4.0 4.0

    Hex Non-hex Hex Non-hex

    11.0 11.0 15.015.0

    4.5 4.5 4.5 4.5

    Hex Non-hex Hex Non-hex

    11.0 11.015.0 15.0

    5.5 5.5 5.5 5.5

    Hex Non-hex Hex Non-hex

    11.0 11.0 15.0 15.0

    6.5 6.5 6.5 6.5

    Hex Non-hex Hex Non-hex

    11.0 11.0 15.0 15.0

    Long

    Short

    17.0

    21.0

    12.0

    4.0

    Application (Body) Art. No.

    3.4 (Only Implantium) DAN 34

    3.4 / 3.8 / 4.3 / 4.8 / 5.8 DANSE

    Analog

    12.0

    4.5

  • 7/26/2019 Catalog Implantium

    27/128

    SuperLine & Implantium Product Catalog 27

    Unit: mm, Scale 1 : 1.5 / mm

    Custom Abutment Abutment screw is included.

    G/H 1.0

    5.5

    CDAB5510H andFXS4510

    Diameter 4.5

    G/H Type Art. No.

    0.5 Hex CDAB 45 05 H

    0.5 Non-hex CDAB 45 05 N

    1.5 Hex CDAB 45 15 H

    1.5 Non-hex CDAB 45 15 N

    5.5

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the custom abutment with fixture.

    4.5

    Hex

    4.5

    Non-hex

    4.5

    Hex

    4.5

    Non-hex

    Diameter 5.5

    G/H Type Art. No.

    1.0 Hex CDAB 55 10 H

    1.0 Non-hex CDAB 55 10 N

    2.0 Hex CDAB 55 20 H

    2.0 Non-hex CDAB 55 20 N

    1.5 1.50.50.5

    5.5

    Hex

    5.5

    Non-hex

    5.5

    Hex

    5.5

    Non-hex

    2.0 2.01.01.0

    Top view

    5.5

    4.5

  • 7/26/2019 Catalog Implantium

    28/128

    SuperLine & Implantium Product Catalog28

    Dual Milling Abutment [Ti-G4]Unit:mm, Scale 1: 1.5 / mm Abutment screw is included.

    G/H 1.5

    12

    DAB55157HL andFXS4510

    Diameter4.0

    Diameter4.5

    Diameter5.5

    G/H Type Art. No.

    1.0 Hex DAB 40 105 HL

    1.0 Non-hex DAB 40 105 NL

    G/H Type Art. No.

    1.5 Hex DAB 45 156 HL

    1.5 Non-hex DAB 45 156 NL

    G/H Type Art. No.

    1.5 Hex DAB 55 157 HL

    1.5 Non-hex DAB 55 157 NL

    2.5 Hex DAB 55 257 HL

    2.5 Non-hex DAB 55 257 NL

    4.0

    1.0 1.0

    Hex

    5.5

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual milling abutment with fixture.

    4.0

    Non-hex

    4.5

    1.5

    1.5 1.5 2.5 2.5

    1.5

    Hex

    4.5

    Non-hex

    5.5

    Hex

    5.5

    Non-hex

    5.5

    Hex

    5.5

    Non-hex

  • 7/26/2019 Catalog Implantium

    29/128

    SuperLine & Implantium Product Catalog 29

    Dual Milling Abutment [Ti-G4]Unit:mm, Scale 1: 1.5 / mm Abutment screw is included.

    Diameter 6.5

    G/H Type Art. No.

    1.5 Hex DAB 65 158 HL

    1.5 Non-hex DAB 65 158 NL

    2.5 Hex DAB 65 258 HL

    2.5 Non-hex DAB 65 258 NL

    3.5 Hex DAB 65 358 HL

    3.5 Non-hex DAB 65 358 NL

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual milling abutment with fixture.

    Diameter 7.5

    G/H Type Art. No.

    2.5 Hex DAB 75 259 HL

    2.5 Non-hex DAB 75 259 NL

    3.5 Hex DAB 75 359 HL

    3.5 Non-hex DAB 75 359 NL

    6.5

    Hex

    6.5

    Non-hex

    6.5

    Hex

    6.5

    Non-hex

    6.5

    Hex

    6.5

    Non-hex

    7.5

    Hex

    7.5

    Non-hex

    7.5

    Hex

    7.5

    Non-hex

    1.5 1.5 2.5 2.5

    3.5 3.5

    2.5 2.53.5 3.5

  • 7/26/2019 Catalog Implantium

    30/128

    SuperLine & Implantium Product Catalog30

    Dual Milling Abutment [Ti-G2]Unit: mm, Scale 1 : 1.5 / mm Abutment screw is included.

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual milling abutment with fixture.

    Diameter4.0

    Diameter4.5

    Diameter5.5

    G/H Type Art. No.

    1.0 Hex DAB 40 105 HG

    1.0 Non-hex DAB 40 105 NG

    G/H Type Art. No.

    1.5 Hex DAB 45 156 HG

    1.5 Non-hex DAB 45 156 NG

    G/H Type Art. No.

    1.5 Hex DAB 55 157 HG

    1.5 Non-hex DAB 55 157 NG

    2.5 Hex DAB 55 257 HG

    2.5 Non-hex DAB 55 257 NG

    4.0

    1.0 1.0

    Hex

    4.0

    Non-hex

    4.5

    1.5 1.5

    Hex

    4.5

    Non-hex

    1.5 1.5 2.5 2.5

    5.5

    Hex

    5.5

    Non-hex

    5.5

    Hex

    5.5

    Non-hex

    G/H 1.5

    12

    DAB55157HG andFXS4510

    5.5

  • 7/26/2019 Catalog Implantium

    31/128

    SuperLine & Implantium Product Catalog 31

    Unit: mm, Scale 1 : 1.5 / mm

    Dual Milling Abutment [Ti-G2]Abutment screw is included.

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual milling abutment with fixture.

    Diameter 6.5

    G/H Type Art. No.

    1.5 Hex DAB 65 158 HG

    1.5 Non-hex DAB 65 158 NG

    2.5 Hex DAB 65 258 HG

    2.5 Non-hex DAB 65 258 NG

    3.5 Hex DAB 65 358 HG

    3.5 Non-hex DAB 65 358 NG

    Diameter 7.5

    G/H Type Art. No.

    2.5 Hex DAB 75 259 HG

    2.5 Non-hex DAB 75 259 NG

    3.5 Hex DAB 75 359 HG

    3.5 Non-hex DAB 75 359 NG

    6.5

    Hex

    6.5

    Non-hex

    6.5

    Hex

    6.5

    Non-hex

    6.5

    Hex

    6.5

    Non-hex

    1.5 1.5 2.5 2.5

    3.5 3.5

    7.5

    Hex

    7.5

    Non-hex

    7.5

    Hex

    7.5

    Non-hex

    2.5 2.53.5 3.5

  • 7/26/2019 Catalog Implantium

    32/128

    SuperLine & Implantium Product Catalog32

    Non-hex

    2.5

    5.5

    4.5

    Angled Abutment [Ti-G4 / 15]Unit: mm, Scale 1 : 1.5 / mm Abutment screw is included.

    G/H 1.5

    10.5

    15

    Hex

    Diameter4.5 | Angled 15

    AAB154515HL andFXS4510

    Diameter5.5 | Angled 15

    1.5

    4.5

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the angled abutment with fixture.

    Non-hex

    1.5

    4.5

    Hex

    2.5

    4.5

    Non-hex

    2.5

    4.5

    Hex

    3.5

    4.5

    Non-hex

    3.5

    4.5

    Hex

    1.5

    5.5

    Non-hex

    1.5

    5.5

    Hex

    2.5

    5.5

    Hex

    3.5

    5.5

    Non-hex

    3.5

    5.5

    G/H Type Art. No.

    1.5 Hex AAB 15 45 15 HL

    1.5 Non-hex AAB 15 45 15 NL

    2.5 Hex AAB 15 45 25 HL

    2.5 Non-hex AAB 15 45 25 NL

    3.5 Hex AAB 15 45 35 HL

    3.5 Non-hex AAB 15 45 35 NL

    G/H Type Art. No.

    1.5 Hex AAB 15 55 15 HL

    1.5 Non-hex AAB 15 55 15 NL

    2.5 Hex AAB 15 55 25 HL

    2.5 Non-hex AAB 15 55 25 NL

    3.5 Hex AAB 15 55 35 HL

    3.5 Non-hex AAB 15 55 35 NL

  • 7/26/2019 Catalog Implantium

    33/128

    SuperLine & Implantium Product Catalog 33

    Unit: mm, Scale 1 : 1.5 / mm

    Angled Abutment [Ti-G4 / 25] Abutment screw is included.

    Non-hex

    2.5

    5.5

    4.5

    G/H 1.5

    10.5

    25

    Hex

    Diameter 4.5 | Angled 25

    AAB254515HL andFXS4510

    Diameter 5.5 | Angled 25

    1.5

    4.5

    Non-hex

    1.5

    4.5

    Hex

    2.5

    4.5

    Non-hex

    2.5

    4.5

    Hex

    3.5

    4.5

    Non-hex

    3.5

    4.5

    Hex

    1.5

    5.5

    Non-hex

    1.5

    5.5

    Hex

    2.5

    5.5

    Hex

    3.5

    5.5

    Non-hex

    3.5

    5.5

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the angled abutment with fixture.

    G/H Type Art. No.

    1.5 Hex AAB 25 45 15 HL

    1.5 Non-hex AAB 25 45 15 NL

    2.5 Hex AAB 25 45 25 HL

    2.5 Non-hex AAB 25 45 25 NL

    3.5 Hex AAB 25 45 35 HL

    3.5 Non-hex AAB 25 45 35 NL

    G/H Type Art. No.

    1.5 Hex AAB 25 55 15 HL

    1.5 Non-hex AAB 25 55 15 NL

    2.5 Hex AAB 25 55 25 HL

    2.5 Non-hex AAB 25 55 25 NL

    3.5 Hex AAB 25 55 35 HL

    3.5 Non-hex AAB 25 55 35 NL

  • 7/26/2019 Catalog Implantium

    34/128

    SuperLine & Implantium Product Catalog34

    Unit: mm, Scale 1 : 1.5 / mm

    Angled Abutment [Ti-G2 / 15] Abutment screw is included.

    Non-hex

    2.5

    5.5

    4.5

    G/H 1.5

    10.5

    15

    Hex

    Diameter4.5 | Angled 15

    AAB154515HGandFXS4510

    Diameter5.5 | Angled 15

    1.5

    4.5

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the angled abutment with fixture.

    Non-hex

    1.5

    4.5

    Hex

    2.5

    4.5

    Non-hex

    2.5

    4.5

    Hex

    3.5

    4.5

    Non-hex

    3.5

    4.5

    Hex

    1.5

    5.5

    Non-hex

    1.5

    5.5

    Hex

    2.5

    5.5

    Hex

    3.5

    5.5

    Non-hex

    3.5

    5.5

    G/H Type Art. No.

    1.5 Hex AAB 15 45 15 HG

    1.5 Non-hex AAB 15 45 15 NG

    2.5 Hex AAB 15 45 25 HG

    2.5 Non-hex AAB 15 45 25 NG

    3.5 Hex AAB 15 45 35 HG

    3.5 Non-hex AAB 15 45 35 NG

    G/H Type Art. No.

    1.5 Hex AAB 15 55 15 HG

    1.5 Non-hex AAB 15 55 15 NG

    2.5 Hex AAB 15 55 25 HG

    2.5 Non-hex AAB 15 55 25 NG

    3.5 Hex AAB 15 55 35 HG

    3.5 Non-hex AAB 15 55 35 NG

  • 7/26/2019 Catalog Implantium

    35/128

    SuperLine & Implantium Product Catalog 35

    Unit: mm, Scale 1 : 1.5 / mm

    Angled Abutment [Ti-G2 / 25] Abutment screw is included.

    Non-hex

    3.5

    4.5

    Non-hex

    2.5

    5.5

    4.5

    G/H 1.5

    10.5

    25

    Hex

    Diameter 4.5 | Angled 25

    AAB254515HG andFXS4510

    Diameter 5.5 | Angled 25

    1.5

    4.5

    Non-hex

    1.5

    4.5

    Hex

    2.5

    4.5

    Non-hex

    2.5

    4.5

    Hex

    3.5

    4.5

    Hex

    1.5

    5.5

    Non-hex

    1.5

    5.5

    Hex

    2.5

    5.5

    Hex

    3.5

    5.5

    Non-hex

    3.5

    5.5

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the angled abutment with fixture.

    G/H Type Art. No.

    1.5 Hex AAB 25 45 15 HG

    1.5 Non-hex AAB 25 45 15 NG

    2.5 Hex AAB 25 45 25 HG

    2.5 Non-hex AAB 25 45 25 NG

    3.5 Hex AAB 25 45 35 HG

    3.5 Non-hex AAB 25 45 35 NG

    G/H Type Art. No.

    1.5 Hex AAB 25 55 15 HG

    1.5 Non-hex AAB 25 55 15 NG

    2.5 Hex AAB 25 55 25 HG

    2.5 Non-hex AAB 25 55 25 NG

    3.5 Hex AAB 25 55 35 HG

    3.5 Non-hex AAB 25 55 35 NG

  • 7/26/2019 Catalog Implantium

    36/128

    SuperLine & Implantium Product Catalog36

    4.5

    Unit: mm, Scale 1 : 1.5 / mm

    Direct-Casting Abutment / Metal-Casing Abutment

    Abutment screw is included.

    G/H 1.0

    12

    4.5

    Direct-Casting Abutment | Gold

    RAB45GH andFXS4510

    4.5G/H 1.0

    12

    4.5

    RAB45CH andFXS4510

    Hex

    G/H Type Art. No. 1.0 Hex RAB 45 GH

    1.0 Non-hex RAB 45 GN

    4.5

    4.5

    12

    1.0

    Metal-Casting Abutment | Co-Cr

    G/H Type Art. No.

    1.0 Hex RAB 45 CH

    1.0 Non-hex RAB 45 CN

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer than other

    sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the direct-casting / metal-casing abutment with fixture.

    Non-hex

    4.5

    4.5

    12

    1.0

    Hex

    4.5

    4.5

    12

    1.0

    Non-hex

    4.5

    4.5

    12

    1.0

  • 7/26/2019 Catalog Implantium

    37/128

    SuperLine & Implantium Product Catalog 37

    Unit: mm, Scale 1 : 1.5 / mm

    Temporary Abutment Abutment screw is included.

    G/H 1.0

    10 8

    4.5

    RAB45THG andFXS4510

    G/H 2.0

    4.5

    RAB4520PHL andFXS4510

    Plastic Temporary Abutment

    Diameter G/H Type Art. No.

    4.5 1.0 Hex RAB 45 THG

    4.5 1.0 Non-hex RAB 45 TNG

    Ti-Temporary Abutment

    Diameter G/H Type Art. No.

    4.5 2.0 hex RAB 45 20 PHL 4.5 2.0 Non-hex RAB 45 20 PNL

    5.5 2.0 hex RAB 55 20 PHL

    5.5 2.0 Non-hex RAB 55 20 PNL

    6.5 2.0 hex RAB 65 20 PHL

    6.5 2.0 Non-hex RAB 65 20 PNL

    Hex

    4.5

    10

    1.0

    4.54.5

    8.0

    2.0

    Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer

    than other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the temporary abutment with fixture.

    Non-hexhex

    Non-hex

    4.5

    10

    1.0

    5.55.5

    8.0

    2.0

    Non-hexhex

    6.56.5

    8.0

    2.0

    Non-hexhex

  • 7/26/2019 Catalog Implantium

    38/128

    SuperLine & Implantium Product Catalog38

    Prosthetic Procedure 3

    Screw Abutment

    Open Tray Technique Closed Tray Technique

    Screw-Retained Restoration

    Abutment Level Impression

    Screw Abutment

    4.5 / 5.5

    Page39

    Angled Screw Abutment

    4.5 / 5.5

    Page40

    Analog

    4.5/5.5

    Page42

    Impression Coping Transfer

    Bridge / Single 4.5 / 5.5

    Page41

    Polishing Protector

    4.5 / 5.5

    Page42

    Ti-Retaining Screw

    Page42

    Impression Technique and Restoration Selection

    Impression Coping Pick-up

    Bridge / Single 4.5 / 5.5

    Page41

    Metal Cylinder4.5 / 5.5

    Page43

    Gold Cylinder

    4.5 / 5.5

    Page43

    Burn-out Cylinder

    4.5 / 5.5

    Page43

    Bridge

    (Non-hex)

    Single

    (Hex)

    Temporary Restoration

    Titanium Cylinder

    4.5 / 5.5

    Page43

    Single

    (Hex)

    Bridge

    (Non-hex)

    Bridge

    (Non-hex)

    Single

    (Hex)

    Bridge

    (Non-hex)

    Single

    (Hex)

  • 7/26/2019 Catalog Implantium

    39/128

    SuperLine & Implantium Product Catalog 39

    Screw Abutment

    Diameter 4.5

    Delivery Holder

    G/H 3.5

    5.5

    SAB5535L andFXS4510

    G/H Art. No.

    1.0 SAB45 10 L

    1.5 SAB45 15 L

    2.5 SAB45 25 L

    3.5 SAB45 35 L

    4.5 SAB45 45 L

    5.5 SAB45 55 L

    1.0 1.5 2.5 3.5 4.5 5.5

    1.5 2.5 3.5 4.5 5.5

    Diameter 5.5

    G/H Art. No.

    1.5 SAB55 15 L

    2.5 SAB55 25 L

    3.5 SAB55 35 L

    4.5 SAB55 45 L

    5.5 SAB55 55 L

    G/H

    G/H

    G/H

    G/H

    Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the screw abutment. Should they be

    used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the screw abutment with fixture.

    Unit: mm, Scale 1 : 1.5 / mm

  • 7/26/2019 Catalog Implantium

    40/128

    SuperLine & Implantium Product Catalog40

    Unit: mm, Scale 1 : 1.5 / mm

    Angled Screw Abutment

    G/H 1.5

    5.5 5.5

    ASA55151518N andFXS4510

    15

    G/H 1.5

    ASA55301518N andFXS4510

    30

    Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the screw abutment. Should they be

    used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the screw abutment with fixture.

    ASASC 20 23

    Angled Screw Abutment Screw

    2.0

    2.3

    7.3

    Delivery Holder

    15

    1.0

    2.0

    Non-hex

    30

    1.0

    2.0

    Non-hex

    15

    1.0

    2.0

    Hex

    30

    1.0

    2.0

    Hex

    15

    1.5

    3.0

    Non-hex

    15

    1.5

    3.0

    Hex

    30

    1.5

    3.0

    Non-hex

    30

    1.5

    3.0

    Hex

    Angled Screw Abutment 4.5

    G/H Type Art. No.

    1.0 Hex ASA 45 1510 18 H

    1.0 Non-hex ASA 45 1510 18 N

    1.0 Hex ASA 45 3010 18 H

    1.0 Non-hex ASA 45 3010 18 N

    2.0 Hex ASA 45 1520 18 H

    2.0 Non-hex ASA 45 1520 18 N

    2.0 Hex ASA 45 3020 18 H

    2.0 Non-hex ASA 45 3020 18 N

    Angled Screw Abutment 5.5

    G/H Type Art. No.

    1.5 Hex ASA 55 1515 18 H

    1.5 Non-hex ASA 55 1515 18 N

    1.5 Hex ASA 55 3015 18 H

    1.5 Non-hex ASA 55 3015 18 N

    3.0 Hex ASA 55 1530 18 H

    3.0 Non-hex ASA 55 1530 18 N

    3.0 Hex ASA 55 3030 18 H

    3.0 Non-hex ASA 55 3030 18 N

  • 7/26/2019 Catalog Implantium

    41/128

    SuperLine & Implantium Product Catalog 41

    Unit: mm, Scale 1 : 1.5 / mm

    Screw Abutment Impression Components

    Impression Coping Pick-up4.54.5

    5.55.5

    Impression Coping Transfer

    4.5

    4.5

    5.55.5

    Diameter Type Art. No.

    4.5 Single Hex SPU 45SL

    4.5 Bridge Non-hex SPU 45BL

    5.5 Single Hex SPU 55SL

    5.5 Bridge Non-hex SPU 55BL

    Diameter Type Art. No.

    4.5 Single Hex STF 45SL

    4.5 Bridge Non-hex STF 45BL

    5.5 Single Hex STF 55SL

    5.5 Bridge Non-hex STF 55BL

    Type Art. No.

    Pick-up SPS 09

    Transfer STS 09

    Impression Coping Screw

    15.0

    9.0

    Bridge (Non-hex)Single (Hex)

    Bridge (Non-hex)Single (Hex)

    Bridge (Non-hex)Single (Hex)

    Bridge (Non-hex)Single (Hex)

  • 7/26/2019 Catalog Implantium

    42/128

    SuperLine & Implantium Product Catalog42

    Diameter Art. No. 4.5 SAN 45L

    5.5 SAN 55L

    5.5Analog

    4.5

    5.5

    Polishing Protector

    4.5

    SRS 18 T

    Ti-Retaining Screw

    Diameter Art. No.

    4.5 SPP 45L

    5.5 SPP 55L

    5.5

    Comfort Cap

    4.5 Diameter Art. No.

    4.5 SCC 45 L

    5.5 SCC 55 L

    5.0 5.0

    12.0 12.0

    1.8

    2.3

    5.55.5

    Ti-Cylinder4.54.5

    Diameter Type Art. No.

    4.5 Single Hex STC 45SG

    4.5 Bridge Non-hex STC 45BG

    5.5 Single Hex STC 55SG

    5.5 Bridge Non-hex STC 55BGBridge (Non-hex)Single (Hex)

    Bridge (Non-hex)Single (Hex)

    8.7

    3.3

    8.7

    3.3

    8.7

    3.3

    8.7

    3.3

    1.8

    1.8

    2.3

    2.3

    Screw Abutment Impression Components

    Unit: mm, Scale 1 : 1.5 / mm

  • 7/26/2019 Catalog Implantium

    43/128

    SuperLine & Implantium Product Catalog 43

    Unit: mm, Scale 1 : 1.5 / mm

    Screw Abutment Impression Components

    Gold Cylinder4.54.5

    5.55.5

    5.55.5

    Burn-out Cylinder4.54.5

    Diameter Type Art. No.

    4.5 Single Hex SGC 45SL

    4.5 Bridge Non-hex SGC 45BL

    5.5 Single Hex SGC 55SL

    5.5 Bridge Non-hex SGC 55BL

    Diameter Type Art. No.

    4.5 Single Hex SBC 45SL

    4.5 Bridge Non-hex SBC 45BL

    5.5 Single Hex SBC 55SL

    5.5 Bridge Non-hex SBC 55BL

    Bridge (Non-hex)Single (Hex)

    Bridge (Non-hex)Single (Hex)

    Bridge (Non-hex)Single (Hex)

    Bridge (Non-hex)Single (Hex)

    12.0 12.0

    12.0 12.0

    12.0 12.0

    12.0 12.0

    1.8

    1.8

    1.8

    1.8

    2.3

    2.3

    Metal Cylinder | Co-Cr4.54.5

    5.55.5

    Diameter Type Art. No.

    4.5 Single Hex SGC 45CSL

    4.5 Bridge Non-hex SGC 45CBL 5.5 Single Hex SGC 55CSL

    5.5 Bridge Non-hex SGC 55CBLBridge (Non-hex)Single (Hex)

    Bridge (Non-hex)Single (Hex)

    12.0 12.0

    12.0 12.0

    1.8

    1.8

    2.3

    2.3

    2.3

    2.3

  • 7/26/2019 Catalog Implantium

    44/128

    SuperLine & Implantium Product Catalog44

    Impression Technique and Restoration Type

    Overdenture Procedure

    Positioner / Mini Ball / Magnetic Attachment

    Mini Ball Abutment3.5

    Page47

    Abutment Level Impression

    Magnetic Attachment

    for Overdenture

    Implant Keeper4.5 / 5.5

    Page48

    Magnetic Assay

    Page48

    Implant Keeper4.5 / 5.5

    Page49

    Magnetic Assay

    Page49

    Mini Ball and Socket Attachment

    for Overdenture

    Positioner Attachment

    for Overdenture

    Mini Ball Impression Coping

    Page47

    Mini Ball Analog

    Page47

    Socket Spacer

    Page47

    Mini Denture Socket and O-ring

    Page47

    Positioner Abutment3.5

    Page45

    Positioner Impression Coping

    Page45

    Positioner Analog

    Page45

    Block Out Spacer

    Page46

    Positioner Metal Socket

    / Plastic Socket

    Page46

    Prosthetic Procedure 4

  • 7/26/2019 Catalog Implantium

    45/128

    SuperLine & Implantium Product Catalog 45

    Positioner

    6.0 7.0

    3.5 3.5

    12.4

    Unit: mm, Scale 1 : 1.5 / mm

    FSMH andPAB3520 andFXS4510

    G/H 2.00.4

    2.3

    5.2

    Positioner Abutment

    G/H Art. No.

    1.0 PAB 35 10

    2.0 PAB 35 20

    3.0 PAB 35 30

    4.0 PAB 35 40

    5.0 PAB 35 50

    6.0 PAB 35 60

    7.0 PAB 35 70

    Positioner Impression Coping

    PIC

    Positioner Analog

    PAN

    4.5

    4.5

    G/H 1.0 2.03.0 4.0 5.0

    3.5 3.5 3.5 3.5 3.5

    Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the positioner abutment. Should they

    be used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the ball abutment with fixture.

  • 7/26/2019 Catalog Implantium

    46/128

    SuperLine & Implantium Product Catalog46

    PositionerUnit: mm, Scale 1 : 1.5 / mm

    Positioner Core Tool

    XPCTArt. No.

    Positioner Plastic Socket

    Positioner Metal Socket

    Positioner Socket Set

    MSHP (Blue)

    MSMP (Orange)

    MSLP (Ivory)

    MSOP (White)

    FSMH

    Retention Force 100gf 300gf 500gf 1,000gf

    Art. No.

    Tilting Type

    10

    Application

    Art. No.

    FSMHS(Tilting Type 10)Art. No.

    2.3

    5.2

    Positioner Block Out Spacer

    PBOSArt. No.0.5

    6.5

    MSHPN (Blue)

    MSMPN (Orange)

    MSLPN (Ivory)

    MSOP (White)

    Retention Force 100gf 300gf 500gf 1,000gfNon Tilting Type

    5

    FSMHSN(Non Tilting Type 5)

    Metal Socket Plastic Socket Block Out spacer

  • 7/26/2019 Catalog Implantium

    47/128

    SuperLine & Implantium Product Catalog 47

    Mini Ball AttachmentUnit: mm, Scale 1 : 1.5 / mm

    GICA

    Mini Ball Impression Coping

    BANL

    Mini Ball Analog

    BPF3 andBAB352018 andFXS4510

    Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the ball abutment. Should they be used

    together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the ball abutment with fixture.

    Female Socket

    G/H 2.0

    2.9

    4.05

    Mini Ball Abutment

    G/H Art. No.

    0 BAB 35 0018

    1.0 BAB 35 1018

    2.0 BAB 35 2018

    3.0 BAB 35 3018

    4.0 BAB 35 4018 5.0 BAB 35 5018

    4.0

    1.8

    3.5

    3.0

    1.8

    3.5

    2.0

    1.8

    3.5

    1.0

    1.8

    3.5

    1.8

    3.3

    5.0

    1.8

    3.5

    Socket Spacer

    5

    4.0

    (BFS3) (BNO1) (BFS2) (BNO2)

    4.05 4.85

    2.9 3.3Art. No.

    BPF3(300~500gf)

    BPF2 (500~700gf)

    (300~500gf) (500~700gf)

    Art. No.

    GBIC3L

    GBIC2L

  • 7/26/2019 Catalog Implantium

    48/128

    SuperLine & Implantium Product Catalog48

    Unit: mm, Scale 1 : 1.5 / mm

    Magnetic Attachment [Dome Type]

    Magnetic Assay

    G/H 2.0

    4.5

    2.0

    MGT4520D andMKP4520D andFXS4510

    Retention Force 350gf

    2.0 4.0

    Application Diameter H Art. No.

    MKP45D 4.5 2.0 MGT 45 20 D

    MKP55D 5.5 2.0 MGT 55 20 D

    Retention Force 700gf

    2.5 2.0

    2.0

    4.5

    5.5

    2.5

    0.5

    6.0

    G/H Art. No.

    1.0 MKP 45 10 D

    2.0 MKP 45 20 D

    3.0 MKP 45 30 D

    4.0 MKP 45 40 D

    5.0 MKP 45 50 D

    6.0 MKP 45 60 D

    Implant Keeper Diameter 4.5

    1.0 3.0 5.0

    G/H

    G/H Art. No.

    1.0 MKP 55 10 D

    2.0 MKP 55 20 D

    3.0 MKP 55 30 D

    4.0 MKP 55 40 D

    5.0 MKP 55 50 D

    6.0 MKP 55 60 D

    Implant Keeper Diameter 5.5

    G/H

    2.0 4.0 6.01.0 3.0 5.0

    G/H

    G/H

    Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the magnetic abutment. Should they be

    used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the magnetic abutment with fixture.

  • 7/26/2019 Catalog Implantium

    49/128

    SuperLine & Implantium Product Catalog 49

    Unit: mm, Scale 1 : 1.5 / mm

    Magnetic Attachment [Flat Type]

    G/H 2.0

    4.5

    1.5

    MGT4515 andMKP4520 andFXS4510

    Retention Force 400gf

    Retention Force 450gf

    Retention Force 700gf

    Retention Force 750gf

    1.5

    2.0

    1.5

    2.0

    4.5

    4.5

    5.5

    5.5

    Magnetic Assay

    Application Diameter H Art. No.

    MKP45 4.5 1.5 MGT 45 15

    MKP45 4.5 2.0 MGT 45 20

    MKP55 5.5 1.5 MGT 55 15

    MKP55 5.5 2.0 MGT 55 20

    2.0 4.0 6.0

    G/H Art. No.

    1.0 MKP 45 10

    2.0 MKP 45 20

    3.0 MKP 45 30

    4.0 MKP 45 40

    5.0 MKP 45 50

    6.0 MKP 45 60

    Implant Keeper Diameter 4.5

    1.0 3.0 5.0

    G/H

    G/H Art. No.

    1.0 MKP 55 10

    2.0 MKP 55 20

    3.0 MKP 55 30

    4.0 MKP 55 40

    5.0 MKP 55 50

    6.0 MKP 55 60

    Implant Keeper Diameter 5.5

    G/H

    2.0 4.0 6.01.0 3.0 5.0

    G/H

    G/H

    Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the magnetic abutment. Should they be

    used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.

    2) It is recommended to keep the torque level at 25~30 Ncm to tighten the magnetic abutment with fixture.

  • 7/26/2019 Catalog Implantium

    50/128

    SuperLine & Implantium Product Catalog50

    Surgical Kit [Full]

    UXIF

    Kit Contents

    Countersink XCS 3629 SW

    XCS 4029 SW

    XCS 4529 SW

    XCS 5029 SW

    XCS 6029 SW

    XCS 7029 SW

    Hand-piece adapter

    Ratchet adapter

    Parallel pin x4

    Path pin x2

    Depth gauge

    Hex driver

    Ratchet

    Drill extension

    XPP 162220 T

    XID 27 H

    XID 32 H

    XID 26 W

    XID 32 W

    XMFPA2

    XHD 26T

    XDE

    XDGL

    XRCA1

    Final drill (Stopper) XFD 3435

    XFD 3835

    Final drill XFD 3429

    XFD 3829

    XFD 4329

    XFD 4829

    XFD 5831

    First guide drill XLD 2229

    XLD 2629Second guide drill

    XLD 2235

    XLD 2635

    (Stopper)

    (Stopper)

    XFD 4335

    XFD 4835

  • 7/26/2019 Catalog Implantium

    51/128

    SuperLine & Implantium Product Catalog 51

    Surgical Kit [Standard]

    UXIFN

    Kit Contents

    Hand-piece adapter

    Ratchet adapter

    Countersink

    Parallel pin

    MF path pin x2

    Hex driver

    Ratchet

    Drill extension

    XCS 3629 SW

    XCS 4029 SW

    XCS 4529 SW

    XCS 5029 SW

    XPP 162220 T

    XPP 162226 T

    XID 30 H

    XID 26 W

    XMFPA2

    XHD 26T

    XDE

    XRCA1

    First guide drillXLD 2231

    XLD 2631Second guide drill

    XCS 6029 SW

    XCS 7029 SW

    Final drill XFD 3431

    XFD 3831

    XFD 4331

    XFD 4831

    XFD 5831

    XHD 25 H

  • 7/26/2019 Catalog Implantium

    52/128

    SuperLine & Implantium Product Catalog52

    Surgical Kit [Short Implant]

    Hand-piece adapter

    Ratchet adapter

    Parallel pin 2

    MF path pin x2

    Hex driver

    Ratchet

    XPP 162212

    XID 27 H

    XID 26 W

    XMFPA2

    XHD 26T

    XRCA1

    First guide drill XLD 2207

    XLD 2607Second guide drill

    Final drill XFC 3607

    XFC 4007

    XFC 4507

    XFC 5007

    XFC 6007

    XFC 7007

    XHD 25 H

    XSIK

    Kit Contents

  • 7/26/2019 Catalog Implantium

    53/128

    SuperLine & Implantium Product Catalog 53

    Drill Stopper Kit

    XDS

    Kit Contents

    Guide drill stopper / First, Second

    XLD 2235

    XLD 2635

    Final drill stopper/ 34, 38

    XFD 34 35

    XFD 38 35

    Stopper-first guide drill, second guide drill

    Stopper-final drill / 34, 38

    XLDST 14 XLDST 12 XLDST 10 XLDST 08 XLDST 06

    XFDST 14 XFDST 12 XFDST 10 XFDST 08 XFDST 06

    Final drill stopper/ 43, 48

    XFD 43 35

    XFD 48 35

    Stopper-final drill / 43, 48

    XFDST 14L XFDST 12L XFDST 10L XFDST 08L XFDST 06L

  • 7/26/2019 Catalog Implantium

    54/128

    SuperLine & Implantium Product Catalog54

    Drill

    Guide Drill

    33

    1.5

    28

    Diameter L Art. No.

    1.5 20 XGD 15 20

    1.5 28 XGD 15 28

    1.5

    20

    33

    First Guide Drill

    Diameter L Art. No.

    2.2 26 XLD 22 07

    2.2 29 XLD 22 29

    2.2 31 XLD 22 31

    2.2 33 XLD 22 33

    2.2 35 XLD 22 35

    2.2 41 XLD 22 41

    Second Guide Drill

    Diameter L Art. No.

    2.6 26 XLD 26 07

    2.6 29 XLD 26 29

    2.6 31 XLD 26 31

    2.6 33 XLD 26 33

    2.6 35 XLD 26 35

    2.6 41 XLD 26 41

    Note: Drill speed 1,000rpm, 30~45Ncm with irrigation.

    First Drill

    2.0

    29

    Diameter L Art. No.

    2.0 29 XFD 20 29

    2.0 33 XFD 20 33

    2.352.6

    1.72.2

    1.72.2 Stopper

    35

    2.352.6 Stopper

    29

    1.72.2

    29

    2.352.6

    26

    1.72.2

    26

    2.352.6

    31

    1.72.2

    31

    2.352.6

    8 10 12 14 16

    2.0

    33

    Unit: mm, Scale 1 : 1 / mm

    41

    1.72.2

    41

    2.352.6

    35

  • 7/26/2019 Catalog Implantium

    55/128

    SuperLine & Implantium Product Catalog 55

    DrillUnit: mm, Scale 1 : 1 / mm

    Note: Drill speed 1,000rpm, 30~45Ncm with irrigation.

    Diameter L Art. No.

    2.9 29 XFD 3429

    3.35 29 XFD 3829

    3.85 29 XFD 4329

    4.4 29 XFD 4829

    5.4 29 XFD 5829SW

    Final Drill | Length-29mm 12

    29

    Diameter L Art. No.

    2.9 31 XFD 3431

    3.35 31 XFD 3831

    3.85 31 XFD 4331

    4.4 31 XFD 4831

    5.4 31 XFD 5831

    Final Drill | Length-31mm2.9

    3.35

    3.85

    14

    4.4

    5.4

    31

    2.9

    3.35

    3.85

    4.4

    5.4

    Diameter L Art. No.

    3.6 27 XFC 3607

    4.0 27 XFC 4007

    4.5 27 XFC 4507

    5.0 27 XFC 5007

    6.0 27 XFC 6007

    7.0 27 XFC 7007

    Final Drill | For Short Implant

    7.0

    27

    3.6

    Pilot Drill

    1.93.0

    30

    Diameter L Art. No.

    3.0 30 XPD 20 30

    2.85

    4.0 3.3

    4.5 3.85

    5.0 4.4

    4.46.0

    7.0 5.4

  • 7/26/2019 Catalog Implantium

    56/128

    SuperLine & Implantium Product Catalog56

    Drill

    Note: Drill speed 1,000rpm, 30~45Ncm with irrigation.

    Diameter L Art. No.

    2.9 33 XFD 3433

    3.35 33 XFD 3833

    3.85 33 XFD 4333

    4.4 33 XFD 4833

    Final Drill | Length-33mm 16

    33

    2.9

    3.35

    3.85

    4.4

    Unit: mm, Scale 1 : 1 / mm

    Diameter L Art. No.

    2.9 35 XFD 3435

    3.35 35 XFD 3835

    3.85 35 XFD 4335

    4.4 35 XFD 4835

    Final Drill | Length-35mm | Stopper

    35

    Diameter L Art. No.

    2.9 41 XFD 3441

    3.35 41 XFD 3841

    3.85 41 XFD 4341

    4.4 41 XFD 4841

    Final Drill | Length-41mm2.9

    3.35

    3.85

    4.4

    16

    41

    2.9

    3.35

    3.85

    4.4

  • 7/26/2019 Catalog Implantium

    57/128

    SuperLine & Implantium Product Catalog 57

    Note: Drill speed 1,000rpm, 30~45Ncm with irrigation.

    DrillUnit: mm, Scale 1 : 1 / mm

    Diameter L Art. No.

    2.85 35 XFH 3435

    3.3 35 XFH 3835

    3.85 35 XFH 4335

    4.4 35 XFH 4835

    Harvest Drill | Length-35mm | Stopper

    35

    2.85

    3.3

    3.85

    4.4

    2.0

    3.0

    3.6

    4.0

    4.5

    5.0

    29

    Countersink

    6.0

    7.0

    Round Bur

    27

    Diameter L Art. No.

    2.0 33 XRB 2033

    3.0 33 XRB 3033

    Diameter L Art. No.

    3.6 29 XCS 3629 SW

    4.0 29 XCS 4029 SW

    4.5 29 XCS 4529 SW

    5.0 29 XCS 5029 SW

    6.0 27 XCS 6029 SW

    7.0 27 XCS 7029 SW

  • 7/26/2019 Catalog Implantium

    58/128

    SuperLine & Implantium Product Catalog58

    StopperUnit: mm, Scale 1 : 1 / mm

    Drilling Depth L Art. No.

    14 4.6 XLDST 14

    12 6.6 XLDST 12

    10 8.6 XLDST 10

    08 10.6 XLDST 08

    06 12.6 XLDST 06

    04 14.6 XLDST 04

    02 16.6 XLDST 02

    XLDST14

    Stopper | For first guide drill, second guide drill

    XLDST12XLDST10

    XLDST08

    XLDST06

    4.45 4.45 4.45 4.45 4.45

    12.610.68.66.6

    4.6

    Drilling Depth L Art. No.

    14 4.6 XFDST 14

    12 6.6 XFDST 12

    10 8.6 XFDST 10

    08 10.6 XFDST 08

    06 12.6 XFDST 06

    04 14.6 XFDST 04

    02 16.6 XFDST 02

    Stopper | For final drill 3435, 3835

    14.6 16.6

    4.45 4.45

    XFDST14XFDST12

    XFDST10

    XFDST08

    XFDST06

    5.14 5.14 5.14 5.14 5.14

    12.610.68.66.6

    4.6

    14.6 16.6

    5.14 5.14

    XLDST04 XLDST02

    XFDST04 XFDST02

    Drilling Depth L Art. No.

    14 4.6 XFDST 14L

    12 6.6 XFDST 12L

    10 8.6 XFDST 10L

    08 10.6 XFDST 08L

    06 12.6 XFDST 06L 04 14.6 XFDST 04L

    02 16.6 XFDST 02L

    Stopper | For final drill 4335, 4835

    XFDST14L

    XFDST12L

    XFDST10L

    XFDST08L

    XFDST06L

    6.14 6.14 6.14 6.14 6.14

    12.610.68.66.6

    4.6

    14.6 16.6

    6.14 6.14

    XFDST04L XFDST02L

  • 7/26/2019 Catalog Implantium

    59/128

    SuperLine & Implantium Product Catalog 59

    Unit: mm, Scale 1 : 1 / mm

    Instrument

    Parallel Pin | For first guide drill, second guide drill

    Diameter Art. No.

    1.6 XPP 162212

    1.6 XPP 162220T

    1.6 XPP 162226T

    Path Pin

    20

    26

    1.6

    15.5

    1.6

    1.6

    L Art. No.

    18.6 XMFPA218.6

    Adapter | Hex 1.28mm

    Type L Art. No.

    27 XID 27H

    Hand-piece 30 XID 30H

    32 XID 32H

    24 XID 24W

    26 XID 26W

    29 XID 29W

    29 XID 32W

    32

    32

    29

    26

    24

    27

    30

    Ratchet

  • 7/26/2019 Catalog Implantium

    60/128

    SuperLine & Implantium Product Catalog60

    Instrument

    Hex Driver | Hex 1.28mm

    Slot Driver

    Type L Art. No.

    Hand-piece 25 XHD 25H

    21 XHD 21W

    25 XHD 25W

    27 XHD 27W

    26 XHD 26T

    30 XHD 30TManual

    Type Art. No.

    SDA 17R

    SDA 25R

    25

    30

    26

    25

    17

    Driver | Manual

    Type Art. No.

    Manual XHDHT

    21

    12

    Drill Extension

    XDE

    26

    Unit: mm, Scale 1 : 1 / mm

    Ratchet

    27

    25

    Ratchet

  • 7/26/2019 Catalog Implantium

    61/128

    SuperLine & Implantium Product Catalog 61

    InstrumentUnit: mm

    Adapter | For screw & ball abutment | Scale 1 : 1 / mm

    Ratchet

    XRCA1

    Torque Wrench | Scale 1 : 0.7 / mm

    XNTW

    Depth Gauge

    XDGL

    Note: One side of Depth Gauge measures the

    osteotomy depth and the other side

    measures the gingival height from the

    top of the implant.

    Type Art. No.

    Hand-piece XMAA1

    Ratchet XMA 21W

    20

    21

    Tissue Punch | Scale 1 : 1 / mm

    XTS40

    Punching size : 4.0

    Adapter | For mini ball abutment | Scale 1 : 1 / mm

    IPST21W21

  • 7/26/2019 Catalog Implantium

    62/128

    SuperLine & Implantium Product Catalog62

    DASK [Dentium Advanced Sinus Kit]

    DASK

    Kit Contents

    DASK drill XRT332035

    XED331035D

    XRT372035

    XRT064025

    XRT084025

    XST083025

    Stopper

    XFDST 08 XFDST 06 XFDST 04 XFDST 02

    Sinus elevation instrumentXSE1L

    XSE2L

    XSE3L

    XSE4L

  • 7/26/2019 Catalog Implantium

    63/128

    SuperLine & Implantium Product Catalog 63

    Sinus Bur Kit / Sinus Kit

    SDK

    Kit Contents

    DASK drill XRT332035

    XED331035D

    XRT372035

    XRT064025

    XRT084025

    XST083025

    StopperXFDST 08 XFDST 06 XFDST 04 XFDST 02

    (XSE1L)

    (XSE2L)

    (XSE3L)

    (XSE4L)

    XSKL

    Sinus Kit

  • 7/26/2019 Catalog Implantium

    64/128

    SuperLine & Implantium Product Catalog64

    DASK / Sinus Bur Kit / Sinus Kit

    XRT332035

    XED331035D

    3.3

    24681012

    3.31.6

    0

    24681012 1 0

    XRT372035 3.7

    24681012 0

    XRT064025

    DASK Drill | Scale 1 : 1.2 / mm

    XRT084025

    XST083025

    6.0

    4.0

    8.0

    8.0

    1.51.5

    XFDST08

    XFDST06

    XFDST04

    5.145.14 5.14 5.14

    14.612.610.6

    16.6

    XFDST02

    Drilling Depth L Art.No.

    08 10.6 XFDST 08

    06 12.6 XFDST 06

    04 14.6 XFDST 04

    02 16.6 XFDST 02

    Stopper | For XRT332035, XRT372035, XED331035D | Scale 1 : 1 / mm

    6.6

    Sinus Elevation Instrument | Scale 1 : 0.45 / mm

    XSE1L

    XSE2L

    XSE3L

    XSE4L

    Note: Drill speed 800 to 1,200rpm, 30~45Ncm with irrigation.

    Crestal

    Approach

    DASK Drill #

    DASK Drill #1

    DASK Drill #2

    DASK Drill #3

    DASK Drill #4

    DASK Drill #5

    DASK Drill #6

    Art.No.

    XRT 332035

    XRT 372035

    XED 331035D

    XRT 064025

    XRT 084025

    XST 083025

    Type

    Lateral

    Approach

    4.0

    Unit: mm

  • 7/26/2019 Catalog Implantium

    65/128

    SuperLine & Implantium Product Catalog 65

    Osteotome Kit

    A B

    Osteotome Kit

    Osteotome compresses the bone laterally, providing denser bony interface

    rather than removing valuable bone from the surgical site.

    Osteotome Kit

    XOF 20 A1

    XOF 34 A1

    XOF 38 A1

    XOF 43 A1

    XOF 48 A1

    XOF 20 B1

    XOF 34 B1

    XOF 38 B1

    XOF 43 B1

    XOF 48 B1

    Osteotome | Final drill type | Scale 1 : 0.4 / mm

    Unit: mm

    Type Art.No. A B

    XOF 20A1 1.7 2.8

    XOF 34A1 2.3 2.8

    XOF 38A1 2.7 3.2

    XOF 43A1 2.8 3.8

    XOF 48A1 3.0 4.3

    XOF 20 B1 1.7 2.8 XOF 34 B1 2.3 2.8

    XOF 38 B1 2.7 3.2

    XOF 43 B1 2.8 3.8

    XOF 48 B1 3.0 4.3

    TypeB

    TypeA

    A B

    XOFBK

    TypeA

    (Convex)

    Type B

    (Concave)

    (Convex)

    (Concave)

    XOFK

    XOFK (TypeA)

    XOFBK (TypeB)

  • 7/26/2019 Catalog Implantium

    66/128

    SuperLine & Implantium Product Catalog66

    Trephine Kit

    Trephine Bur

    Excellent fine cutting

    Strong engagement when attaching the trephine to cortical bone

    Cut-outs facilitates ease of harvest retrieval

    5 scale marks on the Trephine drill from 2mm to 10mm

    Easy harvesting

    Outer InnerDiameter Diameter

    3.0 2.3 XTP 24 03

    4.0 3.3 XTP 34 04

    5.0 4.2 XTP 44 05

    6.0 5.2 XTP 54 06

    7.0 6.1 XTP 64 07

    8.0 7.1 XTP 74 08

    9.0 8.0 XTP 84 09

    10.0 9.0 XTP 94 10

    Art. No.

    Trephine Bur | Scale 1 : 0.5 / mm 3.0

    2.3

    5.0

    4.2

    7.0

    6.1

    9.0

    8.0

    4.0

    3.3

    6.0

    5.2

    8.0

    7.1

    10.0

    9.0

    XIT

    Trephine Kit

    Outer

    Inner

    Outer

    Inner

    Outer

    Inner

    Outer

    Inner

    Outer

    Inner

    Outer

    Inner

    Outer

    Inner

    Outer

    Inner

    37

    23

    14108642

    Unit: mm

  • 7/26/2019 Catalog Implantium

    67/128

    SuperLine & Implantium Product Catalog 67

    Prosthetic Kit

    Hex Driver S/T | Scale 1 : 1 / mm

    Torque Wrench | Scale 1 : 0.5 / mm

    Slot Driver | Scale 1 : 1 / mm

    Hex Driver T/W | Scale 1 : 1 / mm

    Hex Driver L/T | Scale 1 : 1 / mm

    Mount Adapter | Scale 1 : 1 / mm

    T/W Adapter | Scale 1 : 1 / mm

    XHD 15

    SDA 25 R

    XHD 25 W

    XNTW

    XHD 30T

    XMAA1

    XMA 21 W

    XIP

    Mini Ball Adapter | Scale 1 : 1 / mm

    IPST 21 W

  • 7/26/2019 Catalog Implantium

    68/128

    SuperLine & Implantium Product Catalog68

    Unit: mm, Scale 1 : 1 / mm

    Planning Kit

    XPK

    Kit Contents

    Diameter 4.5 | Combi & Dual abutment

    G/H Art.No.

    1.5 PDAB 45 15

    2.5 PDAB 45 25

    3.5 PDAB 45 35

    4.5 PDAB 45 45

    5.5 PDAB 45 55

    Diameter 5.5 | Combi & Dual abutment

    G/H Art.No.1.5 PDAB 55 15

    2.5 PDAB 55 25

    3.5 PDAB 55 35

    4.5 PDAB 55 45

    5.5 PDAB 55 55

    Angled 15 | Angled abutment

    Diameter G/H Art.No.

    4.5 2.0 PAAB 15 45 20

    4.5 4.0 PAAB 15 45 40

    5.5 2.0 PAAB 15 55 20

    5.5 4.0 PAAB 15 55 40

    Angled 25 | Angled abutment

    Diameter G/H Art.No.

    4.5 2.0 PAAB 25 45 20

    4.5 4.0 PAAB 25 45 40

    5.5 2.0 PAAB 25 55 20

    5.5 4.0 PAAB 25 55 40

    Diameter 6.5 | Combi & Dual abutment

    G/H Art.No.1.5 PDAB 65 15

    2.5 PDAB 65 25

    3.5 PDAB 65 35

    4.5 PDAB 65 45

    5.5 PDAB 65 55

    1.5

    G/H

    2.53.5 4.5

    5.5

    5.5

    1.52.5

    3.54.5

    5.5

    152.0

    G/H

    152.0

    154.0

    154.0 25

    2.0

    252.0

    254.0

    254.0

    G/H G/H

    1.52.5

    3.54.5

    G/H

  • 7/26/2019 Catalog Implantium

    69/128

    SuperLine & Implantium Product Catalog 69

    Prosthetic and Laboratory Instrument

    Unit: mm

    Reamer Guide for Screw Abutment | Scale 1 : 1 / mm

    Diameter Art. No.

    4.5 CRG 45 L

    5.5 CRG 55 L

    6.5 CRG 65 L

    Reamer Guide for Combi/Dual Abutment | Scale 1 : 1 / mm

    4.5

    5.5

    6.5

    Bridge

    Single

    Hex Driver | Hex 1.28 mm | Scale 1 : 1 / mm

    L Art. No.

    13 XHD 13

    15 XHD 15

    21 XHD 21

    28 XHD 28

    Type Art. No.

    Bridge SRG BL

    Single SRG SL

    13 15

    2128

    Hex 1.28

  • 7/26/2019 Catalog Implantium

    70/128

    SuperLine & Implantium Product Catalog70

    Prosthetic and Laboratory Instrument

    CRH

    Reamer Handle | Scale 1 : 0.5 / mm

    XHW

    Hand Wrench | Scale 1 : 1 / mm

    CRM

    Reamer (Combi/Dual Abutment) | Scale 1 : 1 / mm

    SRM

    Reamer (Screw Abutment) | Scale 1 : 1 / mm

  • 7/26/2019 Catalog Implantium

    71/128

    SuperLine & Implantium Product Catalog 71

    Help Kit

    XIH

    Unit: mm

    Screw Remover | Scale 1 : 1 / mm

    L Art. No

    25 XRFS2S

    33 XRFS2

    Abutment Hex Remover | Scale 1 : 1 / mm

    L Art. No

    20 XRHR20

    25 XRHR25

    Screw Tap Repair | Scale 1 : 1 / mm

    Type Art. No Tap XRSTR

    11 Guide XRSG11

    8 Guide XRSG8

    Cover & Abutment Screw Remover| Scale 1 : 1 / mm

    L Art. No

    25 XRRHD

    Fixture Remover | Scale 1 : 1 / mm

    Type Art. No XRFRT

    Remover XRFRTF

    XRFRTO

    Wrench XRFRW

    25

    33

    25

    11

    8

    2025

    25 25 25

    11 8

    75

    25

  • 7/26/2019 Catalog Implantium

    72/128

    SuperLine & Implantium Product Catalog72

    SURGICAL MANUAL

    Surgical Drill Sequence I 73

    Surgical Drill Sequence II 75

    Drilling Depth Guide 77

    Fixture Connection 79

    Installation Procedure & Warnings 80Surgical Kit Maintenance 81

  • 7/26/2019 Catalog Implantium

    73/128

    SuperLine & Implantium Product Catalog 73

    Surgical Drill Sequence I

    Drilling Sequence Guide (Final Drill)

    3.6 4.0 4.5

    7.04.5 5.0 6.0 7.0

    Final Drill

    Countersink

    FirstGuide Drill

    SecondGuide Drill

    5.0

    4.03.6

    2.9 3.35 3.85 4.4

    3.6 4.0 4.5 5.0 6.0 5.4 7.0

    2.2 2.6

    8 10 12 14 16

    Platform: 3.6

    Platform: 4.0

    Platform: 4.5

    Platform: 5.0

    Platform: 6.0

    Platform: 7.0

  • 7/26/2019 Catalog Implantium

    74/128

    SuperLine & Implantium Product Catalog74

    Determination of Fixture Top Level

    Top level of fixture needs to be located 0.5mm below

    the marginal crestal bone level to minimize bone loss

    after implantation. However, only for the fixture of

    7mm length, top level of fixture should be located

    0.5mm above the marginal crestal bone level.

    Depth Indication

    Use the depth gauge after first drill / First guide drill to check depth of drilling.

    Place the depth gauge against the wall of the osteotomy.

    Depth

    Gauge

    During Fixture Insertion, 30 ~ 45Ncm Torque at 20rpm is Recommended

    Countersink drill is used in cases with dense cortical bone.

    If the bone density is D1~D3, it is recommended to countersink after final drill.

    The actual diameter of the Countersink drill is 0.1mm larger than the fixture platform.

    +0.5mm

    7mm

    10mm

    CrestalBone-0.5mm

    Length 7mm

  • 7/26/2019 Catalog Implantium

    75/128

    SuperLine & Implantium Product Catalog 75

    Surgical Drill Sequence II

    Drilling Sequence Guide (Havrest Drill)

    3.4 3.8 4.3

    7.04.5 5.0 6.0 7.0

    Harvest Drill

    Countersink

    FirstGuide Drill

    SecondGuide Drill

    4.8

    4.03.6

    2.85 3.3 3.85 4.4

    3.6 4.0 4.5 5.0 6.0 5.4 7.0

    2.2 2.6

    8 10 12 14 16

    Platform: 3.6

    Platform: 4.0

    Platform: 4.5

    Platform: 5.0

    Platform: 6.0

    Platform: 7.0

    : During the 4.3/4.8 fixture insertion into the bone density of D3~D4, the 3.4/3.8 harvest drilling process can be skipped.

    Final Drill

  • 7/26/2019 Catalog Implantium

    76/128

    SuperLine & Implantium Product Catalog76

    Harvest Drill

    Simultaneous and effective autogenous bone collection during the final drilling procedure using a

    specially designed drill

    Sharp pointed tip design of the drill prevents drill chatter and helps guide drill path.

    Available drill stopper helps control drill depth for safe and efficient bone collection, especially in the buccal sideof ridge.

    Recommended drill speed of less than 100rpm/50Ncm helps preserve the vital autogenous bone.

    Excellent clinical results may be achieved when harvested autogenous bone is combined with OSTEON II .

    First / Second guide drill

    1000rpm / 30~45Nm with irrigation

    Harvest drill

    30~100rpm / 30~50Nm without irrigation

    Bone Collection in the Buccal Side of Ridge: 50~200rpm / 30~50Ncm

    Stopper

    Locking with drill stopper for bone collection

    4.0

  • 7/26/2019 Catalog Implantium

    77/128

    SuperLine & Implantium Product Catalog 77

    Drilling Depth Guide

    D1~D2

    D3~D4 Drilling depth of the countersink depends on the patient's bone quality.

    If the bone density is D1~D2, it is recommended to drill up to the top line ( I ) oflaser mark on the countersink.

    If the bone density is D3~D4, it is recommended to drill up to the bottom line ( II )of laser mark on the countersink.

    Countersink Depth Guide

    ( I )

    ( II )

    Final drill

    3.6

    10mm

    Countersink

    3.6

    Second

    guide drill

    First

    guide drill

    Final drill

    3.6

    10mm

    Final drill

    4.0

    Countersink

    4.0

    Second

    guide drill

    First

    guide drill

    Final drill

    3.6

    10mm

    Final drill

    4.0

    Final drill

    4.5

    Countersink

    4.5

    Second

    guide drill

    First

    guide drill

    0.5mm

    0.5mm

    0.5mm

    Platform: 3.6 / Body:3.4 (1000rpm / 30~45Ncm)

    Platform: 4.0 / Body:3.8 (1000rpm / 30~45Ncm)

    Platform: 4.5 / Body:4.3 (1000rpm / 30~45Ncm)

    FX 3410

    3.4

    3.6

    FXS 3610

    3.6

    3.7

    FX 3810

    3.8

    4.0

    FXS 4010

    4.0

    4.0

    FX4310

    4.3

    4.5

    FXS4510

    4.5

    4.5

  • 7/26/2019 Catalog Implantium

    78/128

    SuperLine & Implantium Product Catalog78

    Final drill

    3.6

    10mm

    Final drill

    4.0

    Final drill

    4.5

    Final drill

    5.0

    Countersink

    5.0

    Second

    guide drill

    First

    guide drill

    Final drill

    3.6

    10mm

    Final drill

    4.0

    Final drill

    4.5

    Final drill

    5.0

    Countersink

    6.0

    Second

    guide drill

    First

    guide drill

    Final drill

    3.6

    10mm

    Final drill

    4.0

    Final drill

    4.5

    Final drill

    5.0

    Countersink

    6.0

    Final drill

    7.0

    Countersink

    7.0

    Second

    guide drill

    First

    guide drill

    FXS 6010

    FXS 7010

    5.0

    6.0

    5.8

    7.0

    0.5mm

    0.5mm

    0.5mm

    Platform: 7.0 / Body:5.8 (1000rpm / 30~45Ncm)

    Platform: 5.0 / Body:4.8 (1000rpm / 30~45Ncm)

    Platform: 6.0 / Body:4.8 (1000rpm / 30~45Ncm)

    FX 4810

    4.8

    5.0

    FXS 5010

    5.0

    5.0

  • 7/26/2019 Catalog Implantium

    79/128

    SuperLine & Implantium Product Catalog 79

    Fixture Connection

    Caution_When opening the fixture pack,

    hold the fixture container upward

    and engage the adapter into the

    fixture.

    By hand-piece20rpm / 35Ncm

    By ratchet

    Directions Using the Hand-piece / Ratchet Adapter

    The Hand-piece Adapter/Ratchet Adapter must be connected firmly

    together with the internal hex inside the fixture

    Connection

    Hand-piece

    Adapter

    Ratchet

    Adapter

  • 7/26/2019 Catalog Implantium

    80/128

    SuperLine & Implantium Product Catalog80

    Installation Procedure & Warnings

    Cover Screw

    Warnings

    Dental Implant surgery and restoration involve complex dental procedures. Appropriate and adequate training in proper

    technique is strongly recommended prior to use.

    Improper medical examination and/or treatment plan can result in implant failure and/or loss of supportive bone.

    Improper initial stability and/or excessive occlusal forces during healing period may lead to osseointergration failure.

    Excessive insertion torque may lead to mechanical failure or implant biologic failure due to bone compression and necrosis.

    When forces or loads are greater than its design, implant or abutment fracture could happen. Therefore clinicians should

    make careful decisions with regards to clinical treatment planning to minimize the risk of fracture. Appropriate implant

    quantity, occlusal interface and a nightguard are essential. Potential excessive loading conditions may include the following:

    01 Inadequate number of implants are placed.

    02 Implant width and/or length are inappropriate for a treatment site.

    03 Prosthesis which has excessive cantilever length due to inadequate biomechanical design

    04 Continuous occlusal force are generated by incomplete connection between implant and abutment and/or abutment

    screw loosening.

    05 Direct Casting Abutment angles are greater than 30 from the vertical axis of the implant.

    Direct Abutments are not for angulation.

    06 Occlusal interferences causing excessive lateral forces

    07 Patient parafunctions such as bruxism

    08 Inadequate dental laboratory casting procedures

    09 Improper prosthesis fit

    10 Trauma from patient habits or accidents11 Excessive marginal bone loss caused by inadequate bone width and/or advanced periimplantitis

    Healing Abutment

    By Hex Driver Cover Screw (CS36)connection

    Healing Abutment connectionBy Hex Driver Healing Abutment (HAB402020L)connection in thin gingiva

  • 7/26/2019 Catalog Implantium

    81/128

    SuperLine & Implantium Product Catalog 81

    Surgical Kit Maintenance

    Sterilization and Instrument Care Procedures

    Please follow legal regulations, as well as hygienic guidelines to prevent contamination and infection through prevention.

    Please remember that you are responsible for the maintenance and sterilization of your medical / dental products /device.It is important to use and follow proper cleaning, disinfection and sterilization procedures.

    It is also important to follow the manufactures recommendation on the usage of drills.Please keep a log as to how many times the drills are used.

    Drills are used per implant placed not per patient. Bone density determines the life of the drills.

    Replace white and red o-rings on adapters and hex drivers, if worn and dried out.

    Drills should be considered for replacement around 20 uses based on bone density.

    01 All instruments immediately after use must be pre-soaked for a few minutes in a germicidal bath to loosen andprevent debris from attaching to instruments. Do not soak over-night.

    02 Scrub with a soft brush to remove any debris.

    03 For internal irrigation drills use a reamer or small gauge needle to cleanout drill internally.

    04 If using an ultrasonic cleaner, wrap drills in a 2 2 to prevent rubbing against each other.

    05 Rinse thoroughly under warm water.

    06 Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.

    07 Dry completely and place back into kit.

    08 Always check for damage or corrosion after rinsing and drying.

    09 Seal the tray in a sterilization pouch.

    10 Sterilize using a steam autoclave at 121C / 250for 30 minutes or refer to manufacture's recommendations.

    11 Store in a dry area at room temperature.

    Maintenance Period for Surgical Drills

    All surgical drills shall be replaced after approximately 40 uses based on bone

    density.

    Countersink DrillDepending on bone density,

    the rpm could be adjusted.

    Final Drill

    1000rpm, 30~45Ncm with Irrigation

    Guide Drill (First / Second)

    1000rpm, 30~45Ncm with Irrigation

  • 7/26/2019 Catalog Implantium

    82/128

    SuperLine & Implantium Product Catalog82

    PROSTHESIS MANUAL

    ProstheticIntroduction

    Understanding the Implant and Prosthesis 83

    Types of Abutment 84

    Dual Abutment 85

    Combi Abutment 86

    Dual Milling / Anged / Temporay /Direct-Casting / Metal-Casting Abutment 87

    Screw Abutment / Angled Screw Abutment 89

    Points to Consider in Abutment Selection 90

    Minimum Height Requirement forSuperLine Prosthetic Abutment 91

    Prosthetic Procedure 1 92

    Abutment Level- Dual Abutment 93

    Abutment Level- Combi Abutment 96

    Prosthetic Procedure 2 98

    Fixture Level [Pick-up Type]- Dual Abutment 99

    Fixture Level [Transfer Type]- Dual Abutment 102

    Fixture Level [Transfer Type]- Dual Milling Abutment 105

    Fixture Level [Pick-up Type]- Angled Abutment 107Fixture Level- Direct-Casting Abutment 109

    Fixture Level- Metal-Casting Abutment 110

    Fixture Level [Pick-up Type]- Temporary Abutment 111

    Prosthetic Procedure 3 112

    Abutment Level [Transfer Type]- Screw Abutment 113

    Cementation Repair Method (SCRP) 116

    Prosthetic Procedure 4 118Positioner 119

    Ball Attachment 121

    Magnetic Attachment 122

  • 7/26/2019 Catalog Implantium

    83/128

    SuperLine & Implantium Product Catalog 83

    Understanding the Implant and Prosthesis

    Biological Connection

    The tapered conical hex connection between implantand abutment interface provides hermetic sealing.

    The biological connection distributes the load to thefixture evenly. Therefore it may minimize bone loss.

    All implant diameters share the same internal connection.One abutment screw fits all abutments and fixtures.

    Types of Abutment (Abutments are available in various diameters & gingival heights)

    Dual Abutment

    Combi Abutment

    Dual Abutment

    Dual Milling Abutment

    Angled Abutment (15/25)

    Direct-Casting Abutment

    Metal-Casting Abutment

    Temporary Abutment (Plastic & Titanium)

    Screw AbutmentAngled Screw Abutment (15/ 30)

    Positioner Attachment

    Ball Attachment

    Magnetic Attachment

    Abutment level

    Fixture level

    For denture use

    Screw retained (Abutment level)

  • 7/26/2019 Catalog Implantium

    84/128

    SuperLine & Implantium Product Catalog84

    Angled Abutment

    Abutment Level

    Dual Milling AbutmentCombi Abutment Dual Abutment

    One-Piece Two-Pieces

    Temporary Abutment

    Direct-Casting Abutment

    Types of Abutment

    Straight abutments are Dual and Combi Abutment.

    Depending on the insertion angle and position of the fixture, the Angled or Direct / Metal - Casting Abutment may be used.

    The Screw Abutment can be used when prosthesis retrieval is anticipated.

    Cylinder

    Hex Non-hex

    Screw Abutment

    Hex Non-hex

    Non-hex

    Hex

    Non-hex Hex

    Hex Non-hex

    PlasticTitanium

    Non-hexHex Non-hex

    Selection Guideline

    Ideal emergence profile for each tooth

    (15) (25)

    Hex Non-hex Non-hex

    Metal-Casting Abutment

    HexHex

    (15) (30)

    Fixture Level

  • 7/26/2019 Catalog Implantium

    85/128

    SuperLine & Implantium Product Catalog 85

    Hex Non-hex

    Positioning Jig Unnecessary Required

    Radiograph Required Unnecessary

    Dual Abutment

    Dual Abutment (Hex / Non-hex)

    Diameter G/H Vertical Angle

    4.5 1.0mm, 1.5mm, 2.5mm, 3.5mm, 4.5mm, 5.5mm 5

    5.5 1.0mm, 1.5mm, 2.5mm, 3.5mm, 4.5mm, 5.5mm 6

    6.5 1.0mm, 1.5mm, 2.5mm, 3.5mm, 4.5mm, 5.5mm 7

    Hex / Non-hex

    Non-hexHex

    Dual Abutment

    It is possible to take an impression at both fixture level and abutment level.

    (A Dual Abutment may be interchanged with a Combi Abutment)

    For abutment level impressions, the same prosthetic procedures apply to both Dual and Combi Abutments.

    For fixture level impressions, the abutment selection takes place on the master model.

    For fixture level impressions, a precise positioning jig for abutment may be required.

    Either hex or non-hex abutments may be used, according to operator's preference.

    * If a cement retained restoration requires retrieval, cutting a hole in the occlusal surface would allow access to the screw to permit removal.

    A

  • 7/26/2019 Catalog Implantium

    86/128

    SuperLine & Implantium Product Catalog86

    Combi Abutment

    Combi Abutment Line Up

    Diameter G/H Vertical Angle

    4.5 1.0mm, 1.5mm, 2.5mm, 3.5mm, 4.5mm, 5.5mm 5

    5.5 1.0mm, 1.5mm, 2.5mm, 3.5mm, 4.5mm, 5.5mm 6

    6.5 1.0mm, 1.5mm, 2.5mm, 3.5mm, 4.5mm, 5.5mm 7

    The Combi Abutment is used when the implant position is optimal.

    If the abutment selection is made in the mouth, gauge the thickness of mucosa with the depth gauge to measure the

    gingival height thus allowing the appropriate abutment height.

    The Impression is taken with the snap cap.

    When using the Combi Abutment, it remains in the mouth after the impression is taken.

    (Do not remove or change its position)

    Tighten abutment screw to 25 - 35 Ncm. (retighten again before seating final prosthesis)

    * If the Combi Abutment is too long it can be adjusted 1.5mm to the bottom of the laser mark on the vertical stack of

    the abutment. The Combi Abutment has a short analog for the 1.5mm adjustment.

    * A resin jig can be made to record the reduction if reduced more the 1.5mm.

    Prosthetic part

    Transmucosal part

    Fixture connection partMargin of prosthetic element:

    Sub-gingival, equilibrium,

    supra-gingival

    A

  • 7/26/2019 Catalog Implantium

    87/128

    SuperLine & Implantium Product Catalog 87

    Dual Milling / Angled / Temporary /

    Direct-Casting Abutment / Metal-Casting Abutment

    Dual Milling Abutment

    Impression is taken at fixture level.

    When using a non-hex abutment a precise seating jig should be used.

    Either hex or non-hex abutments may be used, according to operators preference.

    * If a cement retained restoration requires retrieval, cutting a hole in the occlusal surface would allow access to thescrew for removal.

    Direct-Casting Abutment

    Excellent for either single or bridgework

    Used as an esthetic custom made abutment.

    Used when angulation is not ideal and a standard abutment cannot be used.

    Used when there is inadequate inter-arch distance and a standard abutment cannot be used. A fixture level impression is taken, and the soft tissue contours can be supported.

    Angled Abutment

    The Angled Abutment is recommended when the restoration path ofinsertion is unfavorable in either anterior or posterior sites.

    Retention force can be increased through milling process.

    Hex Non-hex Hex Non-hex

    Hex Non-hexNon-hex Non-hexHex

    (15)

    Hex Non-hex

    (25)

    Hex Hex Non-hex

    Dual Milling Abutment

    Temporary Abutment Metal-Casting Abutment

    Angled Abutment

    Direct-Casting Abutment

  • 7/26/2019 Catalog Implantium

    88/128

    SuperLine & Implantium Product Catalog88

    X

    Dual Milling / Angled / Temporary /

    Direct-Casting Abutment / Metal-Casting Abutment

    Temporary Abutment

    Temporary Abutments are available with titanium or plastic.

    The titanium abutment comes in both hex and non-hex with a gingival height of 1.0mm.

    The plastic abutment comes in diameters (4.5, 5.5, 6.5) with a gingival height of 2.0mm.

    Abutment Diameter G/H Angle

    Dual Milling

    Hex Non-hex

    Hex Non-hex

    Hex Non-hex

    Fixture Level Abutment (Hex / Non-hex)

    Hex Non-hex

    Metal-Casting Abutment

    Equivalent results for a fraction of the price

    Our highly affordable metal alloy replaces expensive gold to alleviate financial burden to all.

    Angled

    Direct-Casting

    Abutment

    4.0

    4.5

    5.5

    6.5

    7.5

    1.0mm

    1.5mm

    1.5 / 2.5mm

    1.5 / 2.5 / 3.5mm

    2.5 / 3.5mm

    4.5

    5.5

    1.5mm

    2.5mm

    3.5mm

    1.5mm

    2.5mm

    3.5mm

    15 / 25

    15 / 25

    4.5 1.0mm X

    Hex Non-hex

    Metal-Casting

    Abutment4.5 1.0mm X

    Hex Non-hex

    Ti-Temporary 4.5 1.0mm X

    Hex Non-hex

    Plastic

    Temporary

    4.5

    5.5

    6.5

    2.0mm X

  • 7/26/2019 Catalog Implantium

    89/128

    SuperLine & Implantium Product Catalog 89

    Screw Abutment

    If prosthesis repair is anticipated, use of a Screw Abutment retained prosthesis enables easy

    retrieval.

    Useful for connecting multiple units or when there is a preference for a screw retained prosthesis.

    Useful when respective long axes of implants differ. Each side tapers by 30 and this permits up to 60

    divergence between two abutments.

    Useful when the prognosis of an adjacent restoration is not ideal thus permitting easy retrieval and modification