Catalog About Probe
-
Upload
monica-carroll -
Category
Documents
-
view
220 -
download
0
Transcript of Catalog About Probe
-
8/12/2019 Catalog About Probe
1/42
About the Company
Staveley Instruments is a US manufacturing company based in Kennewick, Washingtonproducing a wide range of innovative NDT equipment and sensors. The company manufactures
all the top names in NDT such as Nortec, Sonic, CPX-160 X-Ray and of course Nortec eddycurrent probes and Harisonic ultrasonic transducers. The latest technology is reflected in eachproduct we produce, including the new PowerLink technology, which allows specialprogramming features to be included on each probe and recalled when used with NortecPowerLinkcompatible instruments.
Our products contribute to quality control and preventive maintenance which leads to costreduction, improved material utilization and better overall results for our many customersthroughout the world.
As part of a family of companies within Staveley NDT Technologies, we have connectionsthroughout the world making us one of the largest NDT companies with global representation.
Staveley Instruments has representation throughout Europe and the United Kingdom, parts ofAfrica and the Far East including Japan and China, Australia and New Zealand as well as theUS, Canada and Mexico.
With this international experience, Staveley Instruments has become more responsive and betterable to meet the future challenges in NDT applications and the problems that you face today withtesting, measurement and quality assurance.
Application Engineering Support
At Staveley Instruments we have engineering staff and application engineers on hand to assistyou with all your NDT applications.
We also have a dedicated staff of Eddy Current Probe and Ultrasonic Transducer engineers tohelp you with all your sensor requirements, particularly if you require a product that must bespecially engineered to your application.
Representation
Staveley Instruments is represented by a well trained team of experienced technicalrepresentatives, most of whom work directly for Staveley Instruments. Each representative isqualified to demonstrate our complete range of products, and assist customers with their
application needs by helping them to select correct solutions.
Page 1Rev 2.2Rev 2.5
-
8/12/2019 Catalog About Probe
2/42
Contents
Page: Description:1 About the company2 Contents3 Eddy Current probe selection4 Eddy Current probe design5 Eddy Current probe design (cont.)6 PowerLink probes7 Rotating Scanner Probes (SPO-5965 series)8 Rotating Scanner Probes (SPO-5393 series)9 Rotating Scanner Probes (RA PROBE series)10 Rotating Scanner Probes (SPO-3564 series)11 Rotating Scanner Probes (SPECIAL PROBES)12 Rotating Scanner Probes (SPECIAL PROBES) cont.13 Rotating Scanner Probes (PS5 series)14 Rotating Scanner Probe Kits for PS5 Scanner15 Rotating Scanner Probes (PS2/PS3 series)16 Rotating Scanner Probes (RC series)17 Rotating Scanner Probes (SNC/SCR series probes for the PS-4
scanner)18 Rotating Scanner probe kits19 Bolt hole probes- standard detachable (B series)20 Bolt hole probes PowerLink detachable (BL series)21 Pencil probes- standard (3551 series)22 Pencil probes- PowerLink (3551L series)23 Pencil probes-standard detachable (P series)24 Pencil probes-PowerLink detachable (PL series)25 Metal shaft probes-standard detachable (P series)26 Metal shaft probes-PowerLink detachable (ML series)27 Surface probes-standard detachable (S series)28 Surface probes-PowerLink detachable (SL series)29 Ring/Donut probes-standard (SPO series)30 Ring/Donut probes-PowerLink (SPO L series )31 Ring/Donut probes-standard detachable (R and RR series)32 Ring/Donut probes-PowerLink detachable (RL and RRL series)33 Sliding probes-standard detachable34 Sliding probes-PowerLink detachable35 Conductivity probes-standard36 Conductivity probes- PowerLink37 ID probes38 OD probes39 General purpose kits40 Documentation41 Special Product Requests
ProbeCompatibility
Each page contains figuressimilar to those above.This represents which
instruments the probes areprimarily designed for.
Nortec 3000
Nortec 1000 Series
Nortec 24
Nortec 19eII
Page 2 Rev 2.2Rev 2.5
WorkStation
PowerStation
Nortec Eddy Current Probes
-
8/12/2019 Catalog About Probe
3/42
-
8/12/2019 Catalog About Probe
4/42
Eddy Current Probe Design
Standard Probe designs
Cost, uniformity and availability make it desirable to use standard probes whenever possible. Many
standard designs, with various frequencies, diameters and detection circuits are listed in this catalog.
Primary applications for standard probes:
Surface probes- are used for discovering flaws both on and below surfaces. Available in a broadfrequency range, their diameters are usually large for accommodating lower frequencies or scanning largeareas.
Pencil probes-have smaller diameter housing coils built for higher frequencies. Applications are usuallylimited to surface flaws because of higher frequency.
Right Angle Pencil Probes- reach areas inaccessible to pencil probes. They normally employ the samecoils and frequencies as pencil probes.
Hand Held Bolt Hole Probes-have coils located at right angles to the probe direction, and are rotated byhand with the fastener removed. Standard and custom diameters are available with absolute anddifferential coils.
Scanner Driven Bolt Hole Probes- are used with mechanical devices for automatically rotating andIndexing into hole. Absolute and differential coils are common at higher frequencies of 500 kHz and2 MHz. They bear close tolerances and are highly reliable.
Donut Probes-are designed to inspect aircraft fastener holes with fasteners in place, and can be used onuneven fastener holes. Various inside/outside diameters and frequencies for different size fasteners anddiffering materials are available.
Sliding Probes-are designed to inspect aircraft fastener holes with fasteners in place, at higher scanrates than donut probes. Common sizes and frequencies using the reflection coil techniques are oftenapplied in major airframe inspection requirements.
ID Probes- usually have a frequency range of 5 kHz to 100 kHz made in absolute or differentialconfigurations. Many body styles are available depending on the inside surfaces of tubes to be inspected.Most probe diameters are made to meet customers' requirements.
OD Probes- are usually designed for a frequency range of 5 kHz to 100 kHz and available in absolute,differential and switchable configurations. Tubes to be inspected are passed through the coil for absoluteor differential flaw detection at high speeds.
Page 4 Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
5/42
Eddy Current Probe Design
Special Probe designs*
Probes are designed to meet customers' special requirements. The accuracy of a design is tested by
placing a test coil over a defect through matching surfaces of the part and the EC probe.
Special configurations are used in many applications. The broadest range is employed in the inspectionof aircraft engines and airframes. These are developed in cooperation with the customer and StaveleyInstruments' designers.
Custom development is done routinely at Staveley Instruments. More than thirty years of experience insolving difficult problems maximizes the performance of instrument and probe. Our understanding ofImpedance Plane Analysis and the performance of certain EC components, are a guide to expectedresults shown on an EC instrument like the Nortec 2000. Impedance changes (Z=X+R) are directresults of changes in the inductive reactance or resistance of the EC field induced into a part. Both phaseand amplitude changes are viewable on the instrument screen.
Coil configurations, diameter and frequency effect sensitivity, but calibration standards are also importantto the success of the EC test. Calibration standards are usually based upon the material to be inspectedcontaining known notches of minimum size for detection. These notches are made by EDM processingfor best results, but a narrow saw cut is adequate in certain situations. Conductivity measurements canbe certified to N.I.S.T.
* See last page cover for more information.
Page 5Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
6/42
PowerLink Technology
Nortecprobes have always set the standard for Performance, Repeatability and Quality. The newgeneration of NortecPowerLink Technology Sensors continue to build on its reputation, now providingan additional Value Added capability when used on Staveley Instruments new line of eddy current
instruments.
PowerLink Eddy Current Probes feature:
Automatic probe setup including frequency, gain, filters, horizontal and vertical position, and alarmgates*.
Common cable configuration allows both bridge and reflection probes to be operated with the samecable.
Provides probe model number, serial number, screen data and space for comments on printout fromStaveleys new eddy current instruments.
Probes are backward compatible with earlier versions of Nortecinstruments, such as the NDT-19eand NDT-24, with the appropriate cable.
Probes are capable of being reprogrammed as the need arises. PowerLink can be bypassed to allow the probe to be used for any applicable test. Level III programming (user programmable) supported in the Nortec WorkStation and PowerStation
instrumentation.
*Any command featured in the instrument documentaion may be programmed into the Nortec PowerLink probes.
Page 6 Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
7/42
Rotating Scanner Probes
Bolt Hole Probes for Spitfire, MiniMite (4 pin Fischer), Hocking and Rohmann Scanners
SPO-5965 expanding probes have a long wearing plastic tip and stainless steel backshell.
Probes are fitted with a 4 pin Fischer connector. These probes are similar to SPO-5000probes but are expanded to their larger diameter. They are designed to allow the use of thesame probe when holes are reamed to a larger diameter. They are also useful to checkunusual hole sizes when a fixed size probe is unavailable.
These probes use a reflection differential type coil operating in the 500 kHz to 3 MHzrange. This makes them suitable for aluminum structures as well as low conductivitymaterials. These probes are also available in kits.
How to Order:
Provide part number, description and working length
Probe DescriptionSPO-5965 .156-.187SPO-5965 .187-.218SPO-5965 .218-.250SPO-5965 .250-.281SPO-5965 .281-.312SPO-5965 .312-.375SPO-5965 .375-.437SPO-5965 .437-.500SPO-5965 .500-.562SPO-5965 .562-.625SPO-5965 .625-.687
SPO-5965 .687-.750SPO-5965 .750-.812
Part Number92300619219979921998092199819219982921998392199789219984921998592301569230157
92301589230159
Working Length (W/L)1.751.752.002.002.002.002.002.002.002.002.00
2.002.00
SPO-5965
Page 7Rev 2.2Rev 2.5
Table Of ContentsMain Index
W/L W/L W/L
>.250" .100" - .249"
Other diameters and working lengths available. Contact the Sensors department at StaveleyInstruments for more information.
-
8/12/2019 Catalog About Probe
8/42
.100" - .249">.250"
W/L W/L
Rotating Scanner Probes
How to Order:
Provide part number, description and working length
Probe DescriptionSPO-5393 5/32SPO-5393 3/16SPO-5393 7/32SPO-5393 1/4SPO-5393 9/32SPO-5393 5/16
SPO-5393 11/32SPO-5393 3/8
SPO-5393 13/32SPO-5393 7/16SPO-5393 1/2
SPO-5393 9/16SPO-5393 5/8
SPO-5393 11/16SPO-5393 3/4
Part Number92199999220000923003592199879219988921998992199909219991921999292199939219994
9219995921999692199979219998
Working Length2.002.002.002.002.002.002.002.002.002.002.00
2.002.002.002.00
Page 8 Rev 2.2Rev 2.5
Bolt Hole Probes for Spitfire, MiniMite (4 pin Fischer), Hocking and RohmannScanners
SPO-5393 probes are a hybrid of the original RA probes and are fitted with a 4 pin Fischer connector.
These probes use a reflection differential type coil operating in the 500 KHz to 3 MHz range. This
makes them suitable for aluminum structures as well as low conductivity materials.
The standard stock types are identified in fractions (1/2). The actual probe size isdiameter .010 (.25mm) below this size to provide clearance. Identify special orders with decimals(.505). These probes will be made to the diameter ordered without under-sizing. The working length(WL) required should also be stated. These probes are also available in kits.
Table Of ContentsMain Index
Other diameters and working lengths available. Contact the Sensors department at StaveleyInstruments for more information.
SPO-5393
-
8/12/2019 Catalog About Probe
9/42
How to Order:
Provide part number, description and working length
Rotating Scanner Probes
Probe DescriptionRA-5/32SRA-5/16SRA-3/16RA-7/32RA-5/16RA-3/8
RA-7/16RA-9/16RA-11/16
Part Number921629092034869203481920348292034859203487920348892162949216295
Working Length (W/L)0.250.301.101.101.501.501.501.501.50
Bolt Hole Probes for RA19, RA2000 and MiniMite (4 pin Lemo) Hand Held Scanners
RA probes are made from durable stainless steel and are non-contact probes. Probes are fitted with
a 4 pin Lemo connector.
These probes use a reflection differential type coil operating in the 500 KHz to 3 MHz range. Thismakes them suitable for aluminum structures as well as low conductivity materials.
The standard stock types are identified in fractions (1/2). The actual probe size isdiameter .010 (.25mm) below this size to provide clearance. Identify special orders with decimals(.500) . These probes will be made to the diameter ordered without under-sizing. The working length(WL) required should also be stated. These probes are also available in kits.
Probe DescriptionRA-1/4S
RA-1/4RA-9/32RA-11/32RA-13/32
RA-1/2RA-5/8RA-3/4
Part Number9203484
9203483921629192162929216293920348992034909216296
W/L
W/L
Diameters
/= .251
.40
Page 9Rev 2.2Rev 2.5
Table Of ContentsMain Index
Other diameters and working lengths available. Contact the Sensors department at StaveleyInstruments for more information.
RA PROBES
-
8/12/2019 Catalog About Probe
10/42
How to Order:
Provide part number, description and working length
Rotating Scanner Probes
Probe DescriptionSPO-3564 .156-.187SPO-3564 .187-.218SPO-3564 .218-.250SPO-3564 .250-.281SPO-3564 .281-.312SPO-3564 .312-.375SPO-3564 .375-.437SPO-3564 .437-.500SPO-3564 .500-.562SPO-3564 .562-.625SPO-3564 .625-.687SPO-3564 .687-.750SPO-3564 .750-.812
Part Number9230078921715392171549217155921715692171579217158921715992171609218785921878692187879218788
Working Length (W/L)1.101.101.101.101.501.501.501.501.501.501.501.501.50
Bolt Hole Probes for RA19, RA2000 and MiniMite (4 pin Lemo) Hand Held Scanners
SPO-3564 expanding probes have a long wearing plastic tip and stainless steel backshell. Probes
are fitted with a 4 pin Lemo connector. These are expandable to 20% above their nominal diameter.They are designed to allow the use of the same probe when holes are reamed to a larger diameter.They are also useful to check unusual hole sizes when a fixed size probe is unavailable.
These probes use a reflection differential type coil operating in the 500 KHz to 3 MHz range. Thismakes them suitable for aluminum structures as well as low conductivity materials. These probes arealso available in kits.
.40
W/L
W/L W/L
>.251 .187-.250 .150-.186
Page 10 Rev 2.2Rev 2.5
Table Of ContentsMain Index
Other diameters and working lengths available. Contact the Sensors department at StaveleyInstruments for more information.
SPO-3564
-
8/12/2019 Catalog About Probe
11/42
How to Order:
Provide part number, description.
1. 2. 3. 4.
Rotating Scanner Probes
Special Scanner Probes for RA19, RA2000, and MiniMite (4 pin Lemo) Hand HeldScanners
These probes are fitted with a 4 pin Lemo connector and RA style coils operating in the 500 KHz to3 MHz range. This makes them suitable for first layer aluminum structures.
1. Surface Inspection Probes (raised head fasteners)- for inspecting the immediate areasurrounding a raised head fastener.
2. Surface Inspection Probes for use in detecting flaws emanating from under fastener heads.Inspection can be done with flush fasteners installed. Probe uses ball bearing guide for alignment.
3. Surface Inspection Probes (non countersink)-for inspecting the immediate area outside of anon countersink hole (fastener must be removed). All probes have a pilot shaft for ease in alignment.Five sizes are available.
4. Countersink Probes for use in detecting flaws in countersinks with the fasteners removed. All
probes are designed for the standard 100 countersink unless otherwise specified. All probes have apilot shaft for ease in alignment. Five sizes are available.
CountersinkSPO-4031-5/32SPO-4031-3/16SPO-4031-7/32SPO-4031-1/4SPO-4031-5/16
Surface Inspection
SPO-2906-(5/32 to3/16)
SPO-4243-(3/16 to7/32)
Part Number92165949216595921659692165979216598
Part Number
9216603
9216599
Non-CountersinkSPO-3986-5/32SPO-3986-3/16SPO-3986-7/32SPO-3986-1/4SPO-3986-5/16
Surface Inspection(Raised fastener)
SPO-4308-5/32
SPO-4307-5/16
Part Number92166049216605921660692166079216608
Part Number
9216602
9216601
Page 11Rev 2.2Rev 2.5
Table Of ContentsMain Index
Special Probes
-
8/12/2019 Catalog About Probe
12/42
How to Order:
Provide part number, description.
Rotating Scanner Probes
Special Scanner Probes for Spitfire, MiniMite (4 pin Fischer), Hocking and RohmannScanners.
These probes are fitted with a 4 pin Fischer connector and RA style coils operating in the 500 KHz to3 MHz range. This makes them suitable for first layer aluminum structures.
1. Surface Inspection Probes (raised head fasteners)- for inspecting the immediate areasurrounding a raised head fastener.
2. Surface Inspection Probes for use in detecting flaws emanating from under fastener heads.Inspection can be done with flush fasteners installed. Probe uses ball bearing guide for alignment.
3. Surface Inspection Probes (non countersink)-for inspecting the immediate area outside of anon countersink hole (fastener must be removed). All probes have a pilot shaft for ease in alignment.Five sizes are available.
4. Countersink Probes for use in detecting flaws in countersinks with the fasteners removed. All
probes are designed for the standard 100 countersink unless otherwise specified. All probes have apilot shaft for ease in alignment. Five sizes are available.
CountersinkSPO-5787-5/32SPO-5787-3/16SPO-5787-7/32SPO-5787-1/4SPO-5787-5/16
Surface Inspection
SPO-6635-(5/32 to3/16)
SPO-6636-(3/16 to7/32)
Part Number92223819222382922238392223849222385
Part Number
9222391
9222392
Non-CountersinkSPO-5786-5/32SPO-5786-3/16SPO-5786-7/32SPO-5786-1/4SPO-5786-5/16
Surface Inspection(Raised fastener)
SPO-5784-5/32
SPO-5785-5/16
Part Number92223869222387922238892223899222390
Part Number
9222393
9222394
1. 2. 3. 4.
Page 12 Rev 2.2Rev 2.5
Table Of ContentsMain Index
Special Probes
-
8/12/2019 Catalog About Probe
13/42
How to Order:
Provide part number, description.
Rotating Scanner Probes
Bolt Hole Probes for NortecPS-5 Stainless Steel and Aluminum Scanners.
These probes are manufactured with a choice of bridge/absolute, bridge/differential or reflection/
differential coils in a variety of frequency ranges. They have a long wearing plastic expandable tip andstainless steel backshell. These probes are expandable to 20% above their nominal diameter. They aredesigned to allow the use of the same probe when holes are reamed to a larger diameter. They are alsouseful to check unusual hole sizes when a fixed sizeprobe is unavailable.
Standard probes are available with a 1.5 working length, other working lengths and probe diameters areavailable.
These probes are also available in kits. The most popular kit is l isted on page 14, other kits are available.
Page 13Rev 2.2Rev 2.5
DescriptionPS5/100KHZ-500KHZ/A.156PS5/100KHZ-500KHZ/A.187PS5/100KHZ-500KHZ/A.218PS5/100KHZ-500KHZ/A.250PS5/100KHZ-500KHZ/A.281PS5/100KHZ-500KHZ/A.312PS5/100KHZ-500KHZ/A.343PS5/100KHZ-500KHZ/A.375PS5/100KHZ-500KHZ/A.406PS5/100KHZ-500KHZ/A.437PS5/100KHZ-500KHZ/A.468PS5/100KHZ-500KHZ/A.500PS5/100KHZ-500KHZ/A.531PS5/100KHZ-500KHZ/A.562PS5/100KHZ-500KHZ/A.593PS5/100KHZ-500KHZ/A.625PS5/100KHZ-500KHZ/A.656PS5/100KHZ-500KHZ/A.687PS5/100KHZ-500KHZ/A.718PS5/100KHZ-500KHZ/A.750
Part Number92176289217629921763092176319217632921763392176349217635921763692176379217638921763992176409217641921764292176439217644921764592176469217647
DescriptionPS5/500KHZ-2MHZ/D.156PS5/500KHZ-2MHZ/D.187PS5/500KHZ-2MHZ/D.218PS5/500KHZ-2MHZ/D.250PS5/500KHZ-2MHZ/D.281PS5/500KHZ-2MHZ/D.312PS5/500KHZ-2MHZ/D.343PS5/500KHZ-2MHZ/D.375PS5/500KHZ-2MHZ/D.406PS5/500KHZ-2MHZ/D.437PS5/500KHZ-2MHZ/D.468PS5/500KHZ-2MHZ/D.500PS5/500KHZ-2MHZ/D.531PS5/500KHZ-2MHZ/D.562PS5/500KHZ-2MHZ/D.593PS5/500KHZ-2MHZ/D.625PS5/500KHZ-2MHZ/D.656PS5/500KHZ-2MHZ/D.687PS5/500KHZ-2MHZ/D.718PS5/500KHZ-2MHZ/D.750
Part Number92176489217520921764992175219217650921752292176519217523921765292175249217653921752592176549217526921765592175279217656921765792176589217528
DescriptionPS5/200KHZ-1MHZ/RD.156PS5/200KHZ-1MHZ/RD.187PS5/200KHZ-1MHZ/RD.218PS5/200KHZ-1MHZ/RD.250PS5/200KHZ-1MHZ/RD.281PS5/200KHZ-1MHZ/RD.312PS5/200KHZ-1MHZ/RD.343PS5/200KHZ-1MHZ/RD.375PS5/200KHZ-1MHZ/RD.406PS5/200KHZ-1MHZ/RD.437PS5/200KHZ-1MHZ/RD.468PS5/200KHZ-1MHZ/RD.500PS5/200KHZ-1MHZ/RD.531PS5/200KHZ-1MHZ/RD.562PS5/200KHZ-1MHZ/RD.593PS5/200KHZ-1MHZ/RD.625PS5/200KHZ-1MHZ/RD.656PS5/200KHZ-1MHZ/RD.687PS5/200KHZ-1MHZ/RD.718PS5/200KHZ-1MHZ/RD.750
Part Number92175699217570921757192175729217573921757492175759217576921757792175789217579921758092175819217582921758392175849217585921758692175879217588
Table Of ContentsMain Index
2.46
2.46
PS-5 Scanner Probes
-
8/12/2019 Catalog About Probe
14/42
Rotating Scanner Probes
Bolt Hole Probe Kits for NortecPS-5 Stainless Steel and Aluminum Scanners.
How to Order:Provide part number, description.
PS5/200KHZ-1MHZ/RD.156
PS5/200KHZ-1MHZ/RD.187PS5/200KHZ-1MHZ/RD.218PS5/200KHZ-1MHZ/RD.250PS5/200KHZ-1MHZ/RD.281PS5/200KHZ-1MHZ/RD.312PS5/200KHZ-1MHZ/RD.343PS5/200KHZ-1MHZ/RD.375PS5/200KHZ-1MHZ/RD.406PS5/200KHZ-1MHZ/RD.437PS5/200KHZ-1MHZ/RD.468PS5/200KHZ-1MHZ/RD.500PS5/200KHZ-1MHZ/RD.531PS5/200KHZ-1MHZ/RD.562PS5/200KHZ-1MHZ/RD.593PS5/200KHZ-1MHZ/RD.625PS5/200KHZ-1MHZ/RD.656PS5/200KHZ-1MHZ/RD.687PS5/200KHZ-1MHZ/RD.718PS5/200KHZ-1MHZ/RD.750
Probe Kit, PS5 AFPart Number 9217666NSN 6635-01-415-9099
PS5/100KHZ-500KHZ/A.156
PS5/100KHZ-500KHZ/A.187PS5/100KHZ-500KHZ/A.218PS5/100KHZ-500KHZ/A.250PS5/100KHZ-500KHZ/A.281PS5/100KHZ-500KHZ/A.312PS5/100KHZ-500KHZ/A.343PS5/100KHZ-500KHZ/A.375PS5/100KHZ-500KHZ/A.406PS5/100KHZ-500KHZ/A.437PS5/100KHZ-500KHZ/A.468PS5/100KHZ-500KHZ/A.500PS5/100KHZ-500KHZ/A.531PS5/100KHZ-500KHZ/A.562PS5/100KHZ-500KHZ/A.593PS5/100KHZ-500KHZ/A.625PS5/100KHZ-500KHZ/A.656PS5/100KHZ-500KHZ/A.687PS5/100KHZ-500KHZ/A.718PS5/100KHZ-500KHZ/A.750
Probe Kit, PS5 AbsolutePart Number 9230230
PS5/500KHZ-2MHZ/D.156
PS5/500KHZ-2MHZ/D.187PS5/500KHZ-2MHZ/D.218PS5/500KHZ-2MHZ/D.250PS5/500KHZ-2MHZ/D.281PS5/500KHZ-2MHZ/D.312PS5/500KHZ-2MHZ/D.343PS5/500KHZ-2MHZ/D.375PS5/500KHZ-2MHZ/D.406PS5/500KHZ-2MHZ/D.437PS5/500KHZ-2MHZ/D.468PS5/500KHZ-2MHZ/D.500PS5/500KHZ-2MHZ/D.531PS5/500KHZ-2MHZ/D.562PS5/500KHZ-2MHZ/D.593PS5/500KHZ-2MHZ/D.625PS5/500KHZ-2MHZ/D.656PS5/500KHZ-2MHZ/D.687PS5/500KHZ-2MHZ/D.718PS5/500KHZ-2MHZ/D.750
Probe Kit, PS5 DifferentialPart Number 9230231
PS-5 PROBE KITDIFFERENTIAL
P/N 9230231
PS-5 PROBE KIT AFP/N 9217666
NSN: 6635-01-415-9099
PS-5 PROBE KITABSOLUTEP/N 9230230
Page 14 Rev 2.2Rev 2.5
PS-5 Scanner Probes
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
15/42
Rotating Scanner Probes
Bolt Hole Probes for PS-2 and PS-3 Scanners.
The SA and SD scanner bolt hole probes are fitted with 4 pin Switchcraft connectors and available with
absolute or differential coils in bridge configuration.
The SA type absolute probe has a shielded 100 kHz coil for aluminum structures. SD type differentialprobes have 500 kHz shielded coils for aluminum and/or low conductivity materials, and provideincreased sensitivity to small defects. Other frequencies are available. Probe body material is of BlackDelrin unless otherwise specified.
How to Order standard probes:
Provide part number, description.Example:
How to Order non-standard probes:Example:
Special order probes should be identified with size in decimals (.505) Working length (WL) required should be stated if different from the standard3.0. If coil is recessed add R
Notes: Probes below .160 are unshielded and have no expansion slot or cheeks. Probes below .220 have no ball end.
SA and SD Scanner Probes
9216318Part Number
SDAbsolute (SA) or Differential (SD)
16Probe Size in X/64
RAdd R if coil is recessed
SDAbsolute (SA) or Differential (SD)
.325Probe diameter
500 kHzFrequency
2 W/LWorking Length
Diameter of probeor Hole
SA AbsoluteShielded
PartNumber
SD DifferentialShielded
PartNumber
Working Length(WL)
.156
.187
.218
.250
.281
.312
.343
.375
.406
.437
.500
.562
.625
.687
.750
4.0mm4.7mm5.5mm6.3mm7.1mm7.9mm
8.7mm9.5mm10.3mm11.1mm12.7mm14.3mm15.9mm17.5mm19.0mm
5/323/167/321/49/325/16
11/323/8
13/327/161/29/165/8
11/163/4
SA-10SA-12SA-14SA-16SA-18SA-20
SA-22SA-24SA-26SA-28SA-32SA-36SA-40SA-44SA-48
921629992163019216302921630392163049216305921630692163079216308921630992163109216311921631292163139216314
SD-10SD-12SD-14SD-16SD-18SD-20SD-22SD-24SD-26SD-28SD-32SD-36SD-40SD-44SD-48
921631592163169216317921631892163199216320921632192163229216323921632492163259216326921632792163289216329
1.41.41.41.41.43.03.03.03.03.03.03.03.03.03.0
Page 15Rev 2.2Rev 2.5
Table Of ContentsMain Index
*Other diameters and working lengths can be made to special order. Standard frequency range for SA absolute probes is 100 KHzto 500KHz. Standard frequency range for SD differential probes is 500KHz to 2MHz.
-
8/12/2019 Catalog About Probe
16/42
Rotating Scanner Probes
Non-Contact Bolt Hole Probes for RC RECHII Scanners
The RC Scanner Bolt hole probes are fitted with a 4 pin Switchcraft connector. RC probes are made of
stainless steel.
The standard coils used are reflection differential. They offer a wide frequency range (typically 500 KHzto 2 MHz) with good signal-to-noise ratio.
RC probes are manufactured for the RECHII High Speed (1500 rpm) Scanner. These probes are notinterchangeable with the PS-2 or PS-3 scanners.
Non-Contact RC style probes are normally ordered .010 (.25mm) less than the hole diameter forclearance. They will operate with more clearance (depending on defect size) with reduced sensitivity.
All RECHII probes are custom made to customer specifications.
How to Order:
Provide Probe Type, Probe diameter and Working length.
Example:
When ordering
All RC probe sizes should be identified using decimals (.___). The probe will be made to the diameter ordered withoutunder sizing. Working lengths should be requested when placing an order.
RC Scanner Probes are available from .050 to 1.500 in diameter. They are designed to be used with the RECHII IIscanner and NDT-25L with RECHII option instruments. They are used to detect minute cracks and defects in titanium,inconel and other low conductivity alloys.
RC Scanner Probes
RCBProbe Type
.240Probe Diameter
WL.800Working Length
RCSAvailable Diameters
.050 to .129
RCAAvailable Diameters
.130 to .169
RCBAvailable Diameters
.170 to .624
RCCAvailable Diameters
.625 to 1.500
Page 16 Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
17/42
Rotating Scanner Probes
Bolt Hole Probes for PS-4 Scanner.(Contact and Non-Contact)
The standard PS-4 probes are fitted with a 6 pin Lemo connector. These probes are made with analuminum backshell and a high quality plastic tip.
The standard coils used are reflection differential, double-ended, shielded. They offer a wide frequencyrange (typically 500 Khz-4 Mhz) with optimum signal to noise ratio. They are used for detecting minutecracks and defects in titanium, inconel and other low conductivity alloys. These probes are offered inthree different styles:
1. SNC (Staveley Non-Contact) are normally ordered .010 (.25mm) less than the hole diameter forclearance. The will operate with more clearance (depending on the defect size) with reducedsensitivity.
2. SCR (Staveley Contact Recessed) are expandable to maintain surface contact. They can beexpanded up to 10% of their nominal size. SCR coils are recessed slightly below the contact surface
which reduces scanning noise and does not require protective tape.
3. SC (Staveley Contact)are the same as SCR probes except the coil is not recessed. They provide thebest sensitivity but require protective tape.
All PS-4 probes are custom made to customer specifications.
How to Order:
Provide Probe Type, Probe diameter and Frequency.Example:
(SCR Staveley Contact Recessed)(SC Staveley Contact)
(SNC- Staveley Non-Contact)
SCR, SNC and SC Scanner Probes
SCRProbe Type
.239Probe Diameter
-S/2Frequency in MHz
-S/2 = 2Mhz-S/6 = 6Mhz
Page 17Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
18/42
Scanner Probe Kits
RA19, RA2000 and MiniMite (4 pin Lemo) Bolt Hole Probe Kits
Stainless Steel, Non Contact
Two Probe Kits are available:
The Standard Kit brings together eight of our most popular sizes in a convenientcarrying case.
The Deluxe Kit is made of 15 sizes ranging from 5/32 to 3/4 in a convenientcarrying case.
Both kits are comprised of our stock, high quality, stainless steel probes. All aremanufactured .010 (.25mm) less than the fractional sizes shown. Standard workinglengths are supplied.
Expanding probes, Contact
Expandable Kit contains eight SPO-3564 probes to cover hole sizes from .187 toover .500. These probes have an expansion range of about 20%.
RA19, 2000 and MiniMite 4 pin Lemo Scanner Kits
How to Order
Provide stock part number and description.
Example: 9216656 Standard RA Kit
Standard RA KitPart Number 9216656
Includes:
92034819203482920348392134859203487920348892034899203490Carrying Case
RA-3/16RA-7/32RA-1/4RA-5/16RA-3/8RA-7/16RA-1/2RA-5/8
Deluxe RA KitPart Number 9216657
Includes:
921629092162939203481920348892034829203489920348392162949216291
920349092034859216295921629292162969203487Carrying Case
RA-5/32RA-13/32RA-3/16RA-7/16RA-7/32RA-1/2RA-1/4RA-9/16RA-9/32
RA-5/8RA-5/16RA-11/16RA-11/32RA-3/4RA-3/8
Expandable Kit (SPO-3564)Part Number 9216658
Includes:
92171539217154921715592171569217157921715892171599217160Carrying Case
SPO-3564 .187-.218SPO-3564 .218-.250SPO-3564 .250-.281SPO-3564 .281-.312SPO-3564 .312-.375SPO-3564 .375-.437SPO-3564 .437-.500SPO-3564 .500-.562
Deluxe RA Probe Kit
Expandable(SPO-3564)
Kit
Page 18 Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
19/42
-
8/12/2019 Catalog About Probe
20/42
Detachable Bolt Hole Probes
How to Order:
Provide part number, description.
Example:
Probe Diameter.156.187.218.250.281.312.343.375.406
.437.500
.562
.625
.687
.750
Part Number922243392222179222434922221892224359222219922243692222209222437
922222192224389222439922222392224409222224
Absolute ShieldedBL/100KHZ-500KHZ/A.156BL/100KHZ-500KHZ/A.187BL/100KHZ-500KHZ/A.218BL/100KHZ-500KHZ/A.250BL/100KHZ-500KHZ/A.281BL/100KHZ-500KHZ/A.312BL/100KHZ-500KHZ/A.343BL/100KHZ-500KHZ/A.375BL/100KHZ-500KHZ/A.406
BL/100KHZ-500KHZ/A.437BL/100KHZ-500KHZ/A.500BL/100KHZ-500KHZ/A.562BL/100KHZ-500KHZ/A.625BL/100KHZ-500KHZ/A.687BL/100KHZ-500KHZ/A.750
BL/Bolt Hole
*BRL if reflection coil
9222218Part Number
100KHZ-500KHZFrequency Range
/AAbsolute
(D if Differentialcoil
.250Probe/ Hole diameter
Note: Probes .156 and below are unshielded and have no expansion slot. Probes below .236 have no ball end. Collaris non-removable in probes .250 to .531 in diameter.
Part Number922244192224429222443922244492224459222446922244792224489222449
922245092224519222452922245392224549222455
Differential ShieldedBL/500KHZ-2MHZ/D.156BL/500KHZ-2MHZ/D.187BL/500KHZ-2MHZ/D.218BL/500KHZ-2MHZ/D.250BL/500KHZ-2MHZ/D.281BL/500KHZ-2MHZ/D.312BL/500KHZ-2MHZ/D.343BL/500KHZ-2MHZ/D.375BL/500KHZ-2MHZ/D.406
BL/500KHZ-2MHZ/D.437BL/500KHZ-2MHZ/D.500BL/500KHZ-2MHZ/D.562BL/500KHZ-2MHZ/D.625BL/500KHZ-2MHZ/D.687BL/500KHZ-2MHZ/D.750
Working length (WL)1.01.01.02.02.02.02.02.02.0
2.02.03.23.23.23.2
*When ordering reflection coils (special order) omit part number and order by description. Lengths shown are approximate.
PowerLink Manual Bolt Hole Probes, Absolute and Differential
The PowerLink detachable bolt hole probes are manual probes available with absolute or differential
coils in bridge or reflection configurations. Internal reference coils ensure accurate balance withoutexternal adaptors. All probes are supplied with an adjustable collar. Common cable compatibility amongmost PowerLink eddy current probes allows one cable to operate probes in either bridge or reflectionconfiguration. All Nortec PowerLink eddy current probesare backward compatible to Nortec NDT-19 and NDT-24instruments. Cables CL/SC/6 for Nortec 2000 series andC/SC/6 7P for NDT-19 and NDT-24 instruments, are soldseperately.
PowerLink technology offers unmatched performancewhen used with Staveleys new eddy currentinstrumentation. PowerLink features automatic proberecognition and documentation, as well as providing theoptimum integration between instrument and sensor.
WL
WL
Page 20 Rev 2.2Rev 2.5
Table Of ContentsMain Index
PowerLink Manual Bolt Hole Probes
-
8/12/2019 Catalog About Probe
21/42
Standard Absolute (Bridge type non-PowerLink)
Part Number92133999213400
Differential Shielded3551 RDF 500Khz3551 RDF 3Mhz
Part Number92133979213398
Differential Unshielded3551 RD 500Khz3551 RD 3Mhz
Frequency Range500Khz-3Mhz3Mhz-6Mhz
Nortec3551 Pencil Probes
The 3551 type pencil probes are supplied with a built-in small diameter, low noise cable and an
adjustable collar. They are available with absolute or differential coils in both bridge and reflectionconfigurations (shielded and unshielded). Shielded coils have an effective sensitive areaapproximately .08 (2mm) diameter. Probes will be supplied with Nortec 8 pin Burndy connectorunless otherwise specified.
How to Order:
Provide part number, description.
Example:
Nortec3551 Pencil Probes
3551 Pencil Probes
3551FType
9204914Part Number
100KHZFrequency
Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz2Mhz-4Mhz4Mhz-6Mhz
Part Number921338292049109204911920491292049139213383
Absolute Unshielded3551 50Khz3551 100Khz3551 500Khz3551 1Mhz3551 2Mhz3551 4Mhz
Absolute Shielded3551 F 50Khz3551 F 100Khz3551 F 500Khz3551 F 1Mhz3551 F 2Mhz3551 F 4Mhz
Part Number921338492049149204915920491692049179213385
Frequency Range100Khz-500Khz500Khz-2Mhz2Mhz-4Mhz4Mhz-6Mhz
Part Number9216590921338692133879213388
Differential Unshielded3551 D 100Khz3551 D 500Khz3551 D 2Mhz3551 D 4Mhz
Standard Differential (Bridge type non-PowerLink)
Differential Shielded3551 DF 100Khz3551 DF 500Khz3551 DF 2Mhz3551 DF 4Mhz
Part Number9216591921338992134289213390
Frequency Range1Khz-100Khz100Khz-1Mhz1Mhz-3Mhz3Mhz-6Mhz
Part Number9216592*921339192133929213393
Absolute Unshielded3551 R 1Khz
3551 R 100Khz3551 R 1Mhz3551 R 3Mhz
Reflection Absolute (non-PowerLink)
Absolute Shielded3551 RF 1Khz
3551 RF 100Khz3551 RF 1Mhz3551 RF 3Mhz
Part Number9216593*921339492133959213396
Reflection Differential (non-PowerLink)
Page 21Rev 2.5
Table Of ContentsMain Index
The 3551 probe has a standard O.D. = .18* Probe diameter =.25
-
8/12/2019 Catalog About Probe
22/42
Nortec3551L PowerLink Pencil Probes
The 3551L type pencil probes are supplied with a built-in small diameter, low noise cable and an
adjustable collar. They are available with absolute or differential coils in both bridge and reflectionconfigurations (shielded and unshielded). Shielded coils have an effective sensitive areaapproximately .08 (2mm) diameter. Probes will be supplied with a Lemo 16 pin connector.
How to Order:
Provide part number, description.
Example:
NortecPowerLink 3551L Pencil Probes
3551 Pencil Probes
3551FLType
9230122Part Number
100KHZFrequency
Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz2Mhz-4Mhz4Mhz-6Mhz
Part Number923011592301169230117923011892301199230120
Absolute Unshielded3551L 50Khz3551 L 100Khz3551 L 500Khz3551 L 1Mhz3551 L 2Mhz3551 L 4Mhz
Standard Absolute (Bridge type)
Absolute Shielded3551 FL 50Khz3551 FL 100Khz3551 FL 500Khz3551 FL 1Mhz3551 FL 2Mhz3551 FL 4Mhz
Part Number923012192301229230123923012492301259230126
Frequency Range100Khz-500Khz500Khz-2Mhz2Mhz-4Mhz4Mhz-6Mhz
Part Number9230127923012892301299230130
Differential Unshielded3551 DL 100Khz3551 DL 500Khz3551 DL 2Mhz3551 DL 4Mhz
Standard Differential (Bridge type)
Differential Shielded3551 DFL 100Khz3551 DFL 500Khz3551 DFL 2Mhz3551 DFL 4Mhz
Part Number9230131923013292301339230134
Frequency Range1Khz-100Khz100Khz-1Mhz1Mhz-3Mhz
Part Number9230103*92301049230105
Absolute Unshielded3551 RL 1Khz
3551 RL 100Khz3551 RL 1Mhz
Reflection Absolute
Absolute Shielded3551 RFL 1Khz
3551 RFL 100Khz3551 RFL 1Mhz
Part Number9230107*92301089230109
Frequency Range500Khz-3Mhz3Mhz-6Mhz
Part Number92301119230112
Differential Unshielded3551 RDL 500Khz3551 RDL 3Mhz
Reflection Differential
Differential Shielded3551 RDFL 500Khz3551 RDFL 3Mhz
Part Number92301139230114
Page 22 Rev 2.2Rev 2.5
Table Of ContentsMain Index
The 3551 probe has a standard O.D. = .18* Probe diameter =.25
-
8/12/2019 Catalog About Probe
23/42
.43
NortecStandard Detachable Pencil Probes
The Nortec standard detachable pencil probes are supplied with an adjustable collar and a high quality
quick release connector.
They are available with absolute or differential coils in both bridge and reflection configurations (shieldedand unshielded). Shielded coils have an effective sensitive area approximately .08 (2mm) diameter.
Cables sold separately.
How to Order:
Provide part number, description.
Example:
NortecStandard Detachable Pencil Probes
Detachable Pencil Probes
PPencil, (PR if reflection)
9213408Part Number
/100KHZ-500KHZ/Frequency range
Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz2Mhz-4Mhz4Mhz-6Mhz
Part Number921340192134029213403921340492134059213406
Absolute UnshieldedP/50Khz-100Khz/AUP/100Khz-500Khz/AUP/500Khz-1Mhz/AUP/1Mhz-2Mhz/AUP/2Mhz-4Mhz/AUP/4Mhz-6Mhz/AU
Detachable Absolute (Bridge type)
Absolute ShieldedP/50Khz-100Khz/AP/100Khz-500Khz/AP/500Khz-1Mhz/AP/1Mhz-2Mhz/AP/2Mhz-4Mhz/AP/4Mhz-6Mhz/A
Part Number921340792134089213014921340992134109213411
Frequency Range500Khz-2Mhz2Mhz-4Mhz4Mhz-6Mhz
Part Number921341292134139213414
Differential UnshieldedP/500Khz-2Mhz/DUP/2Mhz-4Mhz/DUP/4Mhz-6Mhz/DU
Detachable Differential (Bridge type)
Differential ShieldedP/500Khz-2Mhz/DP/2Mhz-4Mhz/DP/4Mhz-6Mhz/D
Part Number921301592134159213416
Frequency Range1Khz-100Khz100Khz-1Mhz1Mhz-3Mhz
Part Number9216538*92134179213418
Absolute UnshieldedPR/1Khz-100Khz/AUPR/100Khz-1Mhz/AUPR/1Mhz-3Mhz/AU
Detachable Reflection Absolute
Absolute ShieldedPR/1Khz-100Khz/APR/100Khz-1Mhz/APR/1Mhz-3Mhz/A
Part Number9216539*92134209213421
Frequency Range500Khz-3Mhz3Mhz-6Mhz
Part Number92134239213424
Differential UnshieldedPR/500Khz-3Mhz/DUPR/3Mhz-6Mhz/DU
Detachable Reflection Differential
Differential ShieldedPR/500Khz-3Mhz/DPR/3Mhz-6Mhz/D
Part Number92134259213426
AAbsolute (D if differential)
Page 23Rev 2.2Rev 2.5
Table Of ContentsMain Index
For bridge probes use cables C/SC/6 (P/N 9113016) or C/RA/6 (P/N 9113017). For reflection probes use cables CR/SC/6 (P/N 9113429)or CR/RA/6 (P/N 9113430). The above probes have a standard O.D. = .18, * Probe diameter =.25
-
8/12/2019 Catalog About Probe
24/42
.43
NortecPowerLink Detachable Pencil Probes
The Nortec PowerLinkdetachable pencil probes are supplied with an adjustable collar and a high
quality quick release connector.
They are available with absolute or differential coils in both bridge and reflection configurations (shieldedand unshielded). Shielded coils have an effective sensitive area approximately .08 (2mm) diameter.
Cables sold separately.
How to Order:
Provide part number, description.
Example:
NortecPowerLink Detachable Pencil Probes
Detachable Pencil Probes
PLPencil, (PRL if reflection)
9222180Part Number
/100KHZ-500KHZ/Frequency range
Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz2Mhz-4Mhz4Mhz-6Mhz
Part Number922241192224129222413922241492224159222417
Absolute UnshieldedPL/50Khz-100Khz/AUPL/100Khz-500Khz/AUPL/500Khz-1Mhz/AUPL/1Mhz-2Mhz/AUPL/2Mhz-4Mhz/AUPL/4Mhz-6Mhz/AU
Detachable Absolute (Bridge type)
Absolute ShieldedPL/50Khz-100Khz/APL/100Khz-500Khz/APL/500Khz-1Mhz/APL/1Mhz-2Mhz/APL/2Mhz-4Mhz/APL4Mhz-6Mhz/A
Part Number922217992221809222162922218192224169222418
Frequency Range500Khz-2Mhz2Mhz-4Mhz4Mhz-6Mhz
Part Number922242692224279222428
Differential UnshieldedPL/500Khz-2Mhz/DUPL/2Mhz-4Mhz/DUPL/4Mhz-6Mhz/DU
Detachable Differential (Bridge type)
Differential ShieldedPL/500Khz-2Mhz/DPL/2Mhz-4Mhz/DPL/4Mhz-6Mhz/D
Part Number922218492221859222186
Frequency Range1Khz-100Khz100Khz-1Mhz1Mhz-3Mhz
Part Number9222419*92224219222422
Absolute UnshieldedPRL/1Khz-100Khz/AUPRL/100Khz-1Mhz/AUPRL/1Mhz-3Mhz/AU
Detachable Reflection Absolute
Absolute ShieldedPRL/1Khz-100Khz/APRL/100Khz-1Mhz/APRL/1Mhz-3Mhz/A
Part Number9222420*92221889222423
Frequency Range500Khz-3Mhz3Mhz-6Mhz
Part Number92224309222431
Differential UnshieldedPRL/500Khz-3Mhz/DUPRL/3Mhz-6Mhz/DU
Detachable Reflection Differential
Differential ShieldedPRL/500Khz-3Mhz/DPRL/3Mhz-6Mhz/D
Part Number92221639222432
AAbsolute (D if differential)
Page 24 Rev 2.2Rev 2.5
Table Of ContentsMain Index
The above probes have a standard O.D. = .18, * Probe diameter =.25Probes use CL/SC/6 cable (P/N 9122083).
-
8/12/2019 Catalog About Probe
25/42
Total Length
Drop
NortecStandard Detachable Metal Shaft Pencil Probes
These general purpose probes are used for surface or near surface crack detection. They are also used
for conductivity and coating thickness measurements. They are available with absolute coils in the bridgeconfiguration (shielded, unshielded and reflection shielded). Reference coils are internal, insuring thebest match to the test coil without an external adapter. These probes include a high quality quick releaseconnector. Cables sold separately.
How to Order:
Provide part number, description.
Example:
NortecStandard Detachable Metal Shaft Probes
Detachable Pencil Probes
PPencil, (PR if reflection)
9213408Part Number
/100KHZ-500KHZ/Frequency range
Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz
Part Number9216190921619192161929216193
Absolute ShieldedP/50Khz-100Khz/A/0.0/4P/100Khz-500Khz/A/0.0/4P/500Khz-1Mhz/A/0.0/4P/1Mhz-2Mhz/A/0.0/4
Straight Shaft
Reflection Absolute ShieldedPR/50Khz-500Khz/A/0.0/4
PR/500Khz-2Mhz/A/0.0/4
Part Number9216194
9216195
Right Angle Shaft .03 Drop
Right Angle Shaft .25 Drop
Right Angle Shaft .50 Drop
AAbsolute Coil
/90Angle at tip
.5Drop at tip
/6Total Length
Frequency Range50Khz-100Khz
100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz
Part Number9216200921620192162029216203
Absolute ShieldedP/50Khz-100Khz/A/90.03/6P/100Khz-500Khz/90.03/6P/500Khz-1Mhz/A/90.03/6P/1Mhz-2Mhz/A/90.03/6
Reflection Absolute ShieldedPR/50Khz-500Khz/A/90.03/6
PR/500Khz-2Mhz/A/90.03/6
Part Number9216204
9216205
Frequency Range50Khz-100Khz
100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz
Part Number9216210921621192162129216213
Absolute ShieldedP/50Khz-100Khz/A/90.25/6P/100Khz-500Khz/90.25/6P/500Khz-1Mhz/A/90.25/6P/1Mhz-2Mhz/A/90.25/6
Reflection Absolute ShieldedPR/50Khz-500Khz/A/90.25/6
PR/500Khz-2Mhz/A/90.25/6
Part Number9216214
9216215
Frequency Range50Khz-100Khz
100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz
Part Number9216220921301392162219216222
Absolute ShieldedP/50Khz-100Khz/A/90.5/6P/100Khz-500Khz/90.5/6P/500Khz-1Mhz/A/90.5/6P/1Mhz-2Mhz/A/90.5/6
Reflection Absolute ShieldedPR/50Khz-500Khz/A/90.5/6
PR/500Khz-2Mhz/A/90.5/6
Part Number9216223
9216224
Page 25Rev 2.2Rev 2.5
Table Of ContentsMain Index
For bridge probes use cables C/SC/6 (P/N 9113016) or C/RA/6 (P/N 9113017). For reflection probes use cables CR/SC/6 (P/N 9113429)or CR/RA/6 (P/N 9113430). Other angles, drops and lengths available.
-
8/12/2019 Catalog About Probe
26/42
Total Length
Drop
NortecPowerLink Detachable Metal Shaft Pencil Probes
These PowerLink Metal Shaft probes are used for surface or near surface crack detection. They are
also used for conductivity and coating thickness measurements. They are available with absolute coils inthe bridge configuration (shielded, unshielded and reflection shielded). Reference coils are internal,insuring the best match to the test coil without an external adapter. Common cable compatibility amongmost PowerLink eddy current probes allows one cable to operate probes in either bridge or reflectionconfiguration. All Nortec PowerLink eddy current probes are backward compatible to NortecNDT-19 and NDT-24 instruments. Cables CL/SC/6 for Nortec 2000 series and C/SC/6 7P for NDT-19and NDT-24 instruments, are sold seperately.
How to Order:
Provide part number, description.
Example:
NortecStandard Detachable Metal Shaft Probes
Detachable Pencil Probes
MLML= Bridge
MRL= Reflection
9222164Part Number
/100KHZ-500KHZ/Frequency range
Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz
Part Number9222165922220292222039222472
Absolute ShieldedML/50Khz-100Khz/A/0.0/4ML/100Khz-500Khz/A/0.0/4ML/500Khz-1Mhz/A/0.0/4ML/1Mhz-2Mhz/A/0.0/4
Straight Shaft
Reflection Absolute ShieldedMRL/50Khz-500Khz/A/0.0/4
MRL/500Khz-2Mhz/A/0.0/4
Part Number9222209
9222210
Right Angle Shaft .03 Drop
Right Angle Shaft .25 Drop
Right Angle Shaft .50 Drop
AAbsolute Coil
/90Angle at tip
.5Drop at tip
/6Total Length
Frequency Range50Khz-100Khz
100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz
Part Number9222473922220492222059230022
Absolute ShieldedML/50Khz-100Khz/A/90.03/6ML/100Khz-500Khz/90.03/6ML/500Khz-1Mhz/A/90.03/6ML/1Mhz-2Mhz/A/90.03/6
Reflection Absolute ShieldedMRL/50Khz-500Khz/A/90.03/6
MRL/500Khz-2Mhz/A/90.03/6
Part Number9222477
9222478
Frequency Range50Khz-100Khz
100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz
Part Number9222474922220692222079230004
Absolute ShieldedML/50Khz-100Khz/A/90.25/6ML/100Khz-500Khz/90.25/6ML/500Khz-1Mhz/A/90.25/6ML/1Mhz-2Mhz/A/90.25/6
Reflection Absolute ShieldedMRL/50Khz-500Khz/A/90.25/6
MRL/500Khz-2Mhz/A/90.25/6
Part Number9222213
9222214
Frequency Range50Khz-100Khz
100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz
Part Number9222476922216492222089230071
Absolute ShieldedML/50Khz-100Khz/A/90.5/6ML/100Khz-500Khz/90.5/6ML/500Khz-1Mhz/A/90.5/6ML/1Mhz-2Mhz/A/90.5/6
Reflection Absolute ShieldedMRL/50Khz-500Khz/A/90.5/6
MRL/500Khz-2Mhz/A/90.5/6
Part Number9222215
9222216
Page 26 Rev 2.2Rev 2.5
Table Of ContentsMain Index
Probes use CL/SC/6 cable (P/N 9122083). Other angles, drops and lengths available.
-
8/12/2019 Catalog About Probe
27/42
NortecStandard Detachable Surface Probes
Detachable surface probes are available in a variety of diameters and frequency ranges. They are
shielded to provide maximum sensitivity and are used for crack detection as well as thicknessmeasurement. Other applications include conductivity and coating thickness measurements. Theseprobes include a high quality quick release connector. Cables sold separately.
How to Order:
Provide part number, description.
Example:
NortecStandard Detachable Surface Probes
Detachable Surface Probes
SSurface, (SR if reflection)
9213012Part Number
/1KHZ-50KHZFrequency range
Frequency Range100Hz-2Khz300Hz-10Khz400Hz-30Khz500Hz-40Khz1Khz-50Khz
5Khz-100Khz100Khz-500Khz
DescriptionS/100Hz-2Khz/.75S/300Hz-10Khz/.62S/400Hz-30Khz/.50S/500Hz-40Khz/.44S/1Khz-50Khz/.31S/5Khz-100Khz/.25
S/100Khz-500Khz/.25
Standard Bridge
Equivalent to Non Detachable SPO Probe
SPO-565, SPO-1125SPO-565A
SPO-1402, SPO-1391SPO-1284, SPO-1598
SPO-2132
Part Number9213549921301192135489213547921301292135469216541
Standard Reflection
/.31Diameter
Diameter.75.62.50.44.31.25.25
Frequency Range
100Hz-5Khz100Hz-20Khz300Hz-40Khz
400Hz-60Khz700Hz-80Khz2Khz-200Khz
Description
SR/100Hz-5Khz/.75SR/100Hz-20Khz/.62SR/300Hz-40Khz/.50
SR/400Hz-60Khz/.44SR/700Hz-80Khz/.31SR/2Khz-200Khz/.25
Equivalent to Non Detachable Alcoprobe andSPO ProbesAPS/20/S
APG/16/S, SPO-2134APB/12.5/S, SPO-2136
APBK/10.5/S, SPO-2025APR/8/S, SPO-2026APR/7/S, SPO-2404
Part Number
921355592135549213553
921355292135519213550
Diameter
.75
.62
.50
.44.31
.25
Page 27Rev 2.2Rev 2.5
Table Of ContentsMain Index
For bridge probes use cables C/SC/6 (P/N 9113016) or C/RA/6 (P/N 9113017). For reflection probes use cables CR/SC/6 (P/N 9113429)or CR/RA/6 (P/N 9113430).
-
8/12/2019 Catalog About Probe
28/42
Nortec PowerLinkDetachable Surface Probes
Detachable Surface Probes
SLSurface, (SRL if reflection)
9222161Part Number
/1KHZ-50KHZFrequency range
Frequency Range100Hz-2Khz300Hz-10Khz
100Khz-500Khz400Hz-30Khz500Hz-40Khz1Khz-50Khz
5Khz-100Khz100Khz-500Khz
DescriptionSL/100Hz-2Khz/.75SL/300Hz-10Khz/.62
SL/100Khz-500Khz/.62SL/400Hz-30Khz/.50SL/500Hz-40Khz/.44SL/1Khz-50Khz/.31SL/5Khz-100Khz/.25
SL/100Khz-500Khz/.25
Standard Bridge
Equivalent to Non Detachable SPO Probe
SPO-565, SPO-1125
SPO-565ASPO-1402, SPO-1391SPO-1284, SPO-1598
SPO-2132
Part Number92221929222193922228292224579222456922216192221969222308
Standard Reflection
/.31Diameter
Diameter.75.62.62.50.44.31.25.25
Frequency Range
100Hz-5Khz100Hz-20Khz300Hz-40Khz
400Hz-60Khz700Hz-80Khz2Khz-200Khz
Description
SRL/100Hz-5Khz/.75SRL/100Hz-20Khz/.62SRL/300Hz-40Khz/.50
SRL/500Hz-60Khz/.44SRL/700Hz-80Khz/.31SRL/2Khz-200Khz/.25
Equivalent to Non Detachable Alcoprobe andSPO ProbesAPS/20/S
APG/16/S, SPO-2134APB/12.5/S, SPO-2136
APBK/10.5/S, SPO-2025APR/8/S, SPO-2026APR/7/S, SPO-2404
Part Number
922245892221609222198
922219992222009222201
Diameter
.75
.62
.50
.44.31
.25
Page 28 Rev 2.2Rev 2.5
NortecPowerLinkDetachable Surface Probes
Detachable surface probes are available in a variety of diameters and frequency ranges. They are
shielded to provide maximum sensitivity and are used for crack detection as well as thicknessmeasurement. Other applications include conductivity and coating thickness measurements. Commoncable compatibility among most PowerLink eddy current probes allows one cable to operate probes ineither bridge or reflection configuration. All Nortec PowerLink eddy current probes are backwardcompatible to Nortec NDT-19 and NDT-24 instruments. Cables CL/SC/6 for Nortec 2000 series andC/SC/6 7P for NDT-19 and NDT-24 instruments, are sold seperately.
NortecPowerLink Detachable Surface Probes
How to Order:
Provide part number, description.
Example:
Table Of ContentsMain Index
Probes use CL/SC/6 cable (P/N 9122083).
-
8/12/2019 Catalog About Probe
29/42
I.D.
O.D.
NortecStandard Ring/ Donut Probes (SPO Series)
Ring/ Donut (encircling) probes are made to fit various fastener head diameters. They are mostly used for
subsurface crack detection with the fastener in place. These probes are supplied with a built-in smalldiameter low noise cable. They are available in both bridge or reflection configurations.
Probes will be supplied with Nortec 8 pin Burndy connector unless otherwise specified. Other sizes andfrequencies are available to meet specific requirements. Contact the Sensors department at StaveleyInstruments for more details.
How to Order:
Provide part number, description.
Example:
NortecStandard Ring/ Donut Probes (SPO Series)
Ring/ Donut Probes
SPO-996 Ring/ Donut ProbeSPO Number
9203307Part Number
Frequency Range500Hz-5Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz200Hz-1Khz200Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz
100Hz-1Khz
DescriptionSPO-996SPO-1589SPO-1747SPO-731SPO-1746SPO-1074SPO-2352SPO-1745SPO-2733SPO-783SPO-1744SPO-1240SPO-1154SPO-1743SPO-2839SPO-1238SPO-1274
SPO-2235
Bridge Ring/ Donut Probes
Part Number920330792140199214020920295092140219204788*921402392140249214025920295192140269214030*92029559214027921402892033949202956
9214029
I.D..30.33.33.34.38.40.42.46.50.50.56.62.62.64.65.75.80
.87
O.D..75.831.001.001.00.80.801.001.001.251.151.121.401.151.401.401.40
1.40
Reflection Ring/ Donut Probes
Frequency Range100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz
DescriptionSPO-2031SPO-2131SPO-2030SPO-2434SPO-2432SPO-2032SPO-2433SPO-2064SPO-2435
Part Number921670292167039216704921670592167069216707921670892167099216710
I.D..30.40.50.54.54.62.62.80.87
O.D..80.801.25.881.151.401.561.401.40
Page 29Rev 2.2Rev 2.5
Table Of ContentsMain Index
* Probes in two halves for limited access area.
-
8/12/2019 Catalog About Probe
30/42
-
8/12/2019 Catalog About Probe
31/42
ID
OD
NortecDetachable Ring/ Donut Probes
Ring/ Donut (encircling) probes are made to fit various fastener head diameters. They are mostly used for
subsurface crack detection with the fastener in place. They are available in both bridge or reflectionconfigurations.
These probes include a high quality quick release connector. Cables sold separately.
How to Order:
Provide part number, description.
Example:
NortecDetachable Ring/ Donut Probes
Frequency Range500Hz-5Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz
DescriptionR/500Hz-5Khz/.30-.75R/100Hz-1Khz/.33-1.00R/100Hz-1Khz/.34-1.00R/100Hz-1Khz/.50-1.00R/100Hz-1Khz/.50-1.15R/100Hz-1Khz/.56-1.15R/100Hz-1Khz/.62-1.40R/100Hz-1Khz/.75-1.40R/100Hz-1Khz/.80-1.40
Bridge Ring/ Donut Probes
Part Number921565092156519215652921565392156549215655921565692156579215658
I.D..30.33.34.50.50.56.62.75.80
O.D..751.001.001.001.251.151.401.401.40
RSurface, (RR if reflection)
9215653Part Number
/100HZ-1KHZFrequency range
/.50Internal Diameter
1.00External Diameter
Equivalent to Non-Detachable SPO probesSPO-996SPO-1747SPO-731SPO-2733SPO-783SPO-1744SPO-1154SPO-1238SPO-1274
Frequency Range100Hz-10Khz100Hz-10Khz100Hz-10Khz
100Hz-10Khz100Hz-10Khz100Hz-5Khz100Hz-5Khz100Hz-5Khz100Hz-5Khz
DescriptionRR/100Hz-10Khz/.30-.80RR/100Hz-10Khz/.40-.80RR/100Hz-10Khz/.50-1.25
RR/100Hz-10Khz/.54-.88RR/100Hz-10Khz/.54-1.15RR/100Hz-5Khz/.62-1.40RR/100Hz-5Khz/.62-1.56RR/100Hz-5Khz/.80-1.40RR/100Hz-5Khz/.87-1.40
Reflection Ring/ Donut Probes
Part Number921565992156609215661
921566292156639215664921566592156669215667
I.D..30.40.50
.54
.54
.62
.62
.80
.87
O.D..80.801.25
.881.151.401.561.401.40
Equivalent to Alcoprobe or SPO probesARP/8/22P SPO-2031
ARP/9.5/22P SPO-2131ARP/12.5/31P SPO-2030
ARP/13.5/24P SPO-2434ARP/13.5/29P SPO-2432ARP/16/36P SPO-2032ARP/16/40P SPO-2333ARP/20/36P SPO-2064ARP/23/36P SPO-2435
Ring/ Donut Probes
Page 31Rev 2.5
Table Of ContentsMain Index
For bridge probes use cables C/SC/6 (P/N 9113016) or C/RA/6 (P/N 9113017). For reflection probes use cables CR/SC/6 (P/N 9113429)or CR/RA/6 (P/N 9113430).
-
8/12/2019 Catalog About Probe
32/42
ID
OD
NortecPowerLinkDetachable Ring/ Donut Probes
Ring/ Donut (encircling) probes are made to f it various fastener head diameters. They are used mostly for
subsurface crack detection with the fastener in place. They are available in both bridge or reflectionconfigurations. Common cable compatibility among most PowerLink eddy current probes allows onecable to operate probes in either bridge or reflection configuration. All Nortec PowerLink eddy currentprobes are backward compatible to Nortec NDT-19 and NDT-24 instruments. Cables CL/SC/6 forNortec 2000 series and C/SC/6 7P for NDT-19 and NDT-24 instruments, are sold seperately.
How to Order:
Provide part number, description.
Example:
Nortec PowerLink Ring/ Donut Probes
Ring/ Donut Probes
Frequency Range500Hz-5Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz
DescriptionRL/500Hz-5Khz/.30-.75RL/100Hz-1Khz/.33-1.00RL/100Hz-1Khz/.34-1.00RL/100Hz-1Khz/.50-1.00RL/100Hz-1Khz/.50-1.25RL/100Hz-1Khz/.56-1.15RL/100Hz-1Khz/.62-1.40RL/100Hz-1Khz/.75-1.40RL/100Hz-1Khz/.80-1.40
Bridge Ring/ Donut Probes
Part Number922223392224799222480922248192224829222483922248492224859222486
I.D..30.33.34.50.50.56.62.75.80
O.D..751.001.001.001.251.151.401.401.40
RLSurface, (RRL if reflection)
9222233Part Number
/500HZ-5KHZFrequency range
/.30-Internal Diameter
.75External Diameter
Equivalent to Non-Detachable SPO probesSPO-996SPO-1747SPO-731SPO-2733SPO-783SPO-1744SPO-1154SPO-1238SPO-1274
Frequency Range100Hz-10Khz100Hz-10Khz100Hz-10Khz
100Hz-10Khz100Hz-10Khz100Hz-5Khz100Hz-5Khz100Hz-5Khz100Hz-5Khz
DescriptionRRL/100Hz-10Khz/.30-.80RRL/100Hz-10Khz/.40-.80RRL/100Hz-10Khz/.50-1.25
RRL/100Hz-10Khz/.54-.88RRL/100Hz-10Khz/.54-1.15RRL/100Hz-5Khz/.62-1.40RRL/100Hz-5Khz/.62-1.56RRL/100Hz-5Khz/.80-1.40RRL/100Hz-5Khz/.87-1.40
Reflection Ring/ Donut Probes
Part Number922223792224879222238
922248892224899222490922249192224929222493
I.D..30.40.50
.54
.54
.62
.62
.80
.87
O.D..80.801.25
.881.151.401.561.401.40
Equivalent to Alcoprobe or SPO probesARP/8/22P SPO-2031
ARP/9.5/22P SPO-2131ARP/12.5/31P SPO-2030
ARP/13.5/24P SPO-2434ARP/13.5/29P SPO-2432ARP/16/36P SPO-2032ARP/16/40P SPO-2333ARP/20/36P SPO-2064ARP/23/36P SPO-2435
Page 32 Rev 2.2Rev 2.5
Table Of ContentsMain Index
Other sizes and frequencies are available to meet specific requirements. Contact the Sensors department at Staveley Instruments for more details.Probes use CL/SC/6 cable (9122083).
-
8/12/2019 Catalog About Probe
33/42
NORTEC
SPO-1958
NORTEC
SPO-1994
NORTEC
SPO-3806
NORTEC
SPO-2664
NortecStandard Sliding Probes
Fixed and adjustable types are available. Operating in the reflection mode, they allow inspection of
fastener rows for surface and subsurface cracks. Sliding probes are directionally sensitive and featureengraved green lines to assist scan orientation to the expected direction of the cracks. Fixed types aremostly used in riveted joints to detect cracks emanating from holes. Penetration is sufficient for fuselagethickness up to.15 (4mm). Adjustable types are used for thicker structures up to .75 (19mm). Theyoperate satisfactorily with various fasteners including magnetic types.
How to Order:
Provide part number, description.
Example:
NortecStandard Sliding Probes
SPO NumberSPO-2210
SPO-3806
SPO-3993
SPO-2664
Cable TypeMicrodot (Dual)
CR/SC/6(Detachable)
CR/SC/6(Detachable)
CR/SC/6(Detachable)
Fixed Types
Part Number9206409
9211636
9216183
9222060
SPO-3806Description
9211636Part Number
ApplicationFor surface cracks and second layer near surfacecracks.
For surface and second layer cracks.
Same as SPO-3806 but will accept larger fastenerheads.
For surface cracks and second layer near surfacecracks.
Frequency Range1Khz-100Khz
1Khz-100Khz
1Khz-100Khz
1Khz-100Khz
Probe Size
L x W x H1.5 x .5 x 1.0
1.5 x .8 x 1.0
1.7 x 1.0 x 1.2
1.5 x .5 x 1.0
SPO NumberSPO-1958
SPO-1994
SPO-1957
Cable TypeMicrodot (Dual)
Microdot (Dual)
Microdot (Dual)
Adjustable Types
Part Number9206405
9206406
9206404
ApplicationPenetration up to .5
Penetration up to .5
Penetration up to .7
Frequency Range100Hz-50Khz
100Hz-20Khz
100Hz-10Khz
Probe SizeL x W x H
1.8 x 1.0 x .7
2.3 x 1.0 x .8
2.8 x 1.3 x .9
CableFor Microdot type
For Microdot type(right angle)
Part Number9116184
9116185
DescriptionSPO-2182
SPO-4139
CableFor detachable type
For detachable type(right angle)
Part Number9113429
9113430
DescriptionCR/SC/6
CR/RA/6
Sliding Probes
Fixed type Adjustable type
Page 33Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
34/42
NORTEC
SPO-1958L
NORTEC
SPO-1994L
NORTEC
SPO-3806L
NORTEC
SPO-2664L
Fixed type Adjustable type
NortecPowerLink Sliding Probes
Fixed and adjustable types are available. Operating in the reflection mode, they allow inspection of
fastener rows for surface and subsurface cracks. Sliding probes are directionally sensitive and featureengraved green lines to assist scan orientation to the expected direction of the cracks. Fixed types aremostly used in riveted joints to detect cracks emanating from holes. Penetration is sufficient forfuselage thickness up to.15 (4mm). Adjustable types are used for thicker structures upto .75 (19mm). They operate satisfactorily with various fasteners including magnetic types.
How to Order:
Provide part number, description.
Example:
Sliding Probes
SPO NumberSPO-2210L
SPO-3806L
SPO-3993L
SPO-2664L
Cable Type16 pin to MDs
CL/SC/6
CL/SC/6
CL/SC/6
Fixed Types
Part Number9222241
9222242
9222243
9230101
SPO-3806LDescription
9222242Part Number
ApplicationFor surface cracks and second layer near surfacecracks.
For surface and second layer cracks.
Same as SPO-3806 but will accept larger fastenerheads.
For surface cracks and second layer near surfacecracks.
Frequency Range1Khz-100Khz
1Khz-100Khz
1Khz-100Khz
1Khz-100Khz
Probe Size
L x W x H1.5 x .5 x 1.0
1.5 x .8 x 1.0
1.7 x 1.0 x 1.2
1.5 x .5 x 1.0
SPO NumberSPO-1958L
SPO-1994L
SPO-1957L
Cable Type16 pin to MDs
16 pin to MDs
16 pin to MDs
Adjustable Types
Part Number9222244
9222245
9222246
ApplicationPenetration up to .5
Penetration up to .5
Penetration up to .7
Frequency Range100Hz-50Khz
100Hz-20Khz
100Hz-10Khz
Probe SizeL x W x H
1.8 x 1.0 x .7
2.3 x 1.0 x .8
2.8 x 1.3 x .9
Cable
16 pin to MDs
Part Number
9122096
Description
16 pin Lemo to 3 pin and micro-dot PowerLink
Cable
CL/SC/6
Part Number
9122083
Description
16 pin Lemo to 7 pin Lemo
Page 34 Rev 2.2Rev 2.5
NortecPowerLink Sliding Probes
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
35/42
NortecStandard Conductivity Probes
Conductivity probes are designed for sorting metals and aluminum
alloys, determining heat-treatment condition or damage. Theseprobes were developed for Nortec conductivity instruments. Standardfrequency of the probes for the NDT-5 and 5A is 100 KHz (60 KHzmanufactured at customer request).
These probes are supplied only with connectors for the instrumentsspecified, and are not interchangeable with other instruments.
Probes require instrument to be calibrated by Staveley InstrumentsService Department for accurate operation.
How to Order:
Provide part number, type and frequency.
Example:
NortecStandard Conductivity Probes
Conductivity Probes
Part Number92029329202935*9216635
Diameter.75.75.31
For Use with NDT-5 (8% to 110% IACS)
Probe3049A3049E
SPO-3897
Frequency100KHZ100KHZ100KHZ
Length2.752.752.75
3049AType
9202932Part Number
100KhzFrequency
Part Number92029339202934*9216634
Diameter.75.75.31
For Use with NDT-5A (26% to 65% IACS)
Probe3049C3049D
SPO-887
Frequency100KHZ100KHZ100KHZ
Length2.752.752.75
Part Number9206106(1)9206414(2)
Diameter.75.31
For Use with NDT-17 (24% to 65% IACS)
ProbeSPO-2460SPO-1688
Frequency60KHZ60KHZ
Length1.002.75
(1) Probe includes LED, (2) Probe does not include LED.
Page 35Rev 2.2Rev 2.5
Table Of ContentsMain Index
*Heavy Duty Cable
-
8/12/2019 Catalog About Probe
36/42
NortecPowerLink Conductivity Probes
Nortec PowerLink conductivity probes are designed to be used with Nortec 1700, 2000, 3000,
and WorkStation instruments. They are designed for sorting metals and aluminum alloys, determiningheat-treatment condition or damage. Standard frequencies of the probes is 60 Khz and 480 Khz.
These probes are supplied with a 16 pin Lemo connector and are not interchangeable with otherinstruments.
How to Order:
Provide part number, type and frequency.
Example:
NortecPowerLink Conductivity Probes
Conductivity Probes
Lt. Wt. Conductivity probeType
9222340Part Number
Part Number
9222340
9222341*
9222360
9222361*
Diameter
.75
.75
.31
.31
For Use with N1700, 2000, 3000 and WorkStation (8% to 110% IACS)
Descripiton
Lt. Wt. 60KhzConductivity probe
Lt. Wt. 480KhzConductivity probe
SPO-887L 60KhzConductivity probe
SPO-887L 480KhzConductivity probe
Frequency
60Khz
480Khz
60Khz
480Khz
Height
1.0
1.0
2.75
2.75
60KhzFrequency
60 Khz Lt. Wt. Conductivity Probe
Page 36 Rev 2.2Rev 2.5
Table Of ContentsMain Index
* Not for use with N3000 instrument.
-
8/12/2019 Catalog About Probe
37/42
-
8/12/2019 Catalog About Probe
38/42
OD Probes
NortecOD Probes
These probes have encircling type coils to surround rods or tubes. OD
probes are available in three different coil configurations.
1) Absolute style These detect changes in conductivity and are alsoused in monitoring the heat treating process. The absolute coil can alsobe used to monitor wall thickness to detect thinning in tube walls.
2) Differential style Primarily used for pit and crack detection.
3) Switchable These can be used in either mode.
OD coils are manufactured with long wearing stainless steel faceplates.Standard probe hole sizes range from .015 to 1.50. Due to the widevariety of sizes and frequencies, OD coils are manufactured to customerspecifications when ordered.
NortecOD Probes
How to order
Example:
OD(1)Probe Type
/10KhzFrequency
/.525Actual Probe Diameter(2)
ACoil Type
Absolute-(A)Differential-(D)Switchable-(S)
(1) To order the PowerLink version of this probe order as ODL
(2) The amount of clearance needed is dictated by the frequency and material to be inspected. If you are unsureplease contact the Sensors Department at Staveley Instruments for more details.
Probes are manufactured for easy mounting. Probe size, L=3.0 x W=1.2 x H=3.1.
The standard probes are fitted with a detachable Lemo triaxle connector. PowerLink probes will be fitted with a7 pin Lemo connector. Cables are sold seperately. For standard probes (Lemo triaxle) use the standard detachablecable C/SC/6 (P/N 9113016).
For PowerLink probes use the detachable cable CL/SC/6 (P/N 9122083).
Page 38 Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
39/42
General Purpose Probe Kits
General Purpose Kits
The Nortec probe kits contain five of our most widely used probes, an aluminum crack standard and a block of
six conductivity samples. The kits are available in either the standard probe series with integral 6 cables with8 pin Burndy connectors, or the detachable series with a C/SC/6 cable included (8 pin Burndy)
Detachable Training Kit
This kit contains two surface probes (covering a wide frequency range), two pencil and two bolt hole probes(absolute and differential), one right angle pencil probe, two detachable bridge cables (straight and right angle),and one SPO-3806 sliding reflection probe with cable. Also included are a set of plastic shim stocks, analuminum crack standard, a thinning standard, a second layer crack standard, a TB-16 hole standard, and one setof six conductivity samples. This kit is available with Detachable Probes only.
How to Order
Provide part number and description
Example: 9216632 Standard Probe Kit
Standard Probe Kit Stock Part No. 9216632Includes: 1)9204899 SP-10A 10 KHz Surface Probe
1)9204903 SP-100 100KHz Surface Probe1)9204905 SP-500 500KHz Surface Probe1)9204915 3551F 500KHz Pencil Probe1)9213428 3551DF 2 MHz Pencil Probe1)1902474 Set of Six Conductivity Samples1)1902510 TB-SI Aluminum Crack Standard
Carrying Case
Detachable Probe Kit Stock Part No. 9216633Includes: 1)9213011 S/300KHz-10KHz/.62 Surface Probe
1)9213012 S/1 KHz-50KHz/.31 Surface Probe1)9213013 P/100KHz-500KHz/A/90.5/6 Right Angle
Pencil probe1)9213014 P/500KHz-1MHz/A Pencil Probe1)9213015 P/500KHz-2MHz/D Pencil Probe1)9113016 C/SC/6 6 Cable Straight Connector1)1902474 Set of Six Conductivity Samples1)1902510 TB-S1 Aluminum Crack Standard
Carrying Case
Detachable Training Kit - Stock Part No. 9216655Includes: 1)9213011 S/300KHz-10KHz/.62 Surface Probe
1)9213012 S/1KHz-50KHz/.31 Surface Probe1)9213013 P/100KHz-500KHz/A/90.5/6 Right Angle
Pencil probe1)9213014 P/500KHz-1MHz/A Pencil Probe1)9213015 P/500KHz-2MHz-D Pencil Probe1)9113016 C/SC/6 6 Cable Straight Connector
1)1902474 Set of Six Conductivity Samples1)1902510 TB-SI Aluminum Crack Standard1)5319540 Set of Plastic Shims1)1902477 TB-16 Hole Standard1)9216156 B/100KHz-500KHz/A.250 Bolt Hole Probe1)9216171 B/500KHz-2MHz/D.250 Bolt Hole Probe1)9113017 C/RA/6 6 Cable Right Angle Connector1)9211636 SPO-3806 Sliding Probe1)1916914 SPO-4304 Thinning Sample .039 to .1641)1916915 SPO-3932 Second Layer Crack Standard
(1/16 on 1/16 Aluminum w/fasteners)Carrying Case
Probe Kit 9216632
Page 39Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
40/42
Documentation
Probe Documentation
A Test Documentation Form is supplied with all standard Eddy Current Probes. Each probe is tested on a sample
or standard relevant to the probe diameter and frequency, for proper signal response. In addition a Certificate ofConformanceis available upon request.
Page 40 Rev 2.2Rev 2.5
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
41/42
Special Product Requests
You may mail your request to: Staveley Instruments, Inc. , 421 N. Quay St., Kennewick WA 99336You may fax your request to: (509) 735-4672 or e-mail your request to: [email protected]
Contact Information:
Name:__________________________________
Company:_______________________________
Address:____________________________________________________________________________________________________________________________________
Telephone: (______)_______________________
Fax: (______)____________________________
E-mail: _________________________________
Is there a similar probe to the one you require in the probe catalog? Yes No (CHECK ONE)If yes please indicate page number and part number ifapplicable,___________________________________________
If there is a similar probe in this catalog what alterations would you require?____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Type of flaw:
Material to be tested:______________________________________________________________________
Is the flaw located on the surface, subsurface or both?_______________________
Depth of penetration required?_______________ What is the typical flaw size (L X W X D*)? _________________
What is the maximum flaw size to be detected (L X W X D*)?_______________________________
What is the orientation of the flaw?
*L= lengthW= widthD= depth
Instrument or connection:
What instrument do you wish this probe to connect with (CHECK ONE)?
Nortec 1000 PowerStation
Nortec 2000S, 2000D Nortec 19e, 19eII
Nortec 3000 Nortec 24
WorkStation Other
If other please specify:
Page 41Rev 2.4
Table Of ContentsMain Index
-
8/12/2019 Catalog About Probe
42/42
Special Product Requests
What type of probe would you like to use (CHECK AS MANY AS APPLY)?
Absolute Pencil probe Other
Differential Surface probe
Bridge I/D probe
Reflection O/D probe
Use the area below to sketch your requirements.
Table Of ContentsMain Index