Case Study – Abnormal Appearing Ganglion in the dorsal wrist

50
CASE STUDY – ABNORMAL APPEARING GANGLION IN THE DORSAL WRIST Paige Fabre

description

Case Study – Abnormal Appearing Ganglion in the dorsal wrist. Paige Fabre. Patient Presentation. 34 year old female patient Working as cleaner on the mines – FIFO worker History Several months dorsal wrist pain - PowerPoint PPT Presentation

Transcript of Case Study – Abnormal Appearing Ganglion in the dorsal wrist

Page 1: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

CASE STUDY – ABNORMAL APPEARING GANGLION IN THE DORSAL WRIST

Paige Fabre

Page 2: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

PATIENT PRESENTATION 34 year old female patient Working as cleaner on the mines – FIFO

worker History

Several months dorsal wrist pain Lump appearing on the dorsal aspect of the

wrist, increasing in size while at work, decreasing while at home

No previous imaging, investigations or interventional treatment

Page 3: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ULTRASOUND REQUEST

The examination was requested by the patient’s GP

A “wrist ultrasound +/- aspiration and injection” was requested

“Lump on dorsal wrist ? Ganglion” was the clinical indication given for the exam

Page 4: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ULTRASOUND PROTOCOL

No exact protocol is require for a wrist ultrasounds

Images taken and areas examined are determined by the sonographer and reporting radiologist

Page 5: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

PROTOCOL FOR THE EXAMINATION As I am still in training, my supervisor

suggested that I examine all compartments of the dorsal wrist in longitudinal and transverse to gain a better understanding of the anatomy.

If these areas were normal then I was to image them in transverse to demonstrate that these areas have viewed. An additional image was to be taken of Compartment 3 as it crosses over Compartment 2.

Page 6: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ROOM PREPARTATION The room was prepared before the patient

entered. A chair was placed on the side of the bed

(opposite the machine) facing the towards the bed.

A bluey was positioned on the table where the patient was to place their arms.

The ultrasound machine was moved to the foot end of the bed to allow for more ergonomic scanning.

Appropriate high frequency transducers were attached to the machine or within close proximity.

A pre-prepared injection trolley was brought into the room.

Page 7: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ROOM PREPARATION Image of room to go here

Page 8: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

PATIENT PREPARATION

At admission to the practice the patient read and completed a consent form for aspiration and injection of the wrist in preparation for this being carried out.

The patient was wearing an elbow length shirt and was therefore not required to change.

The patient’s identity was confirmed and they were invited into the room.

Page 9: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

PATIENT PREPARATION The examination was discussed with the

patient before any scanning was attempted. The patient was made aware that I was in

training and that my supervisor would be assisting me with the scan. The patient was asked if this would be acceptable, and their consent was gained.

The patient was also made aware that we would first perform the diagnostic scan and from that the radiologist would decide the best course of action for the procedure.

Page 10: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ULTRASOUND EXAMINATION

The examination was performed on a Toshiba Aplio 500 using a variable frequency 18mHz linear transducer.

Thick ultrasound gel was applied to the area of examination to allow for light pressure and sufficient contact.

Page 11: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ULTRASOUND IMAGES OF THE COMPARTMENTS

Page 12: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

COMPARTMENT 1

Image 1: Left dorsal wrist in transverse showing abductor pollicus longus and extensor pollicus brevis tendons.

Page 13: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

COMPARTMENT 2

Image 2: Left dorsal wrist in transverse showing extensor carpi radialis longus and extensor carpi radialis brevis tendons.

Page 14: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

COMPARTMENT 3

Image 3: Left dorsal wrist in transverse showing extensor pollicus longus tendon. Also in view the ERCB, Lister’s tubercle and Compartment 4.

Page 15: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

COMPARTMENT 3 LONG

Image 4: Left dorsal wrist showing the extensor pollicus longus tendon crossing over Compartment 2.

Page 16: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

COMPARTMENT 4

Image 5: Left dorsal wrist in transverse showing extensor digitorum communis and extensor indicis proprius tendons.

Page 17: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

COMPARTMENT 4

Image 6: Left dorsal wrist in transverse showing extensor digitorum communis and extensor indicis proprius tendons. This image is taken distally to Image 5, demonstrating the distal separation of the tendons.

Page 18: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

COMPARTMENT 5

Image 7: Left dorsal wrist in transverse showing extensor digiti minimi.

Page 19: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

COMPARTMENT 6

Image 8: Left dorsal wrist in transverse showing extensor carpi ulnaris.

Page 20: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

EXTENSION OF THE EXAMINATIONThe compartments of the wrist were examined in both longitudinal and transverse planes. The compartments were all deemed normal and the examination was extended to allow for better visualisation of the lump as described by the patient.

Page 21: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

EXTENSION OF THE EXAMINATION

The following images were taken over the lump as identified by the patient as the region of interest.

Page 22: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ROI IMAGES

Image 9: Left dorsal wrist in the region of interest. This image displays the “lump” superior to the scapho-lunate ligament.

Page 23: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ROI IMAGES

Image 10: Left dorsal wrist in the region of interest. Calipers are used to measure the height and width of the predominately hypoechoic area present.

Page 24: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ROI IMAGES

Image 11: Left dorsal wrist in the region of interest. Calipers are used to measure the length of the predominately hypoechoic area present.

Page 25: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ROI IMAGES

Image 12: Left dorsal wrist in the region of interest. Colour Doppler has been used to identify the possibility of vascularity.

Page 26: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ROI IMAGES

Image 13: Left dorsal wrist in the region of interest. Colour Doppler used to demonstrate the possibility of vascularity. A second image was done to highlight the anechoic region.

Page 27: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ROI IMAGES

Image 14: Left dorsal wrist in the region of interest. Calipers are used to measure what appeared to be a neck of a possible ganglion extending from the radio-carpal joint.

Page 28: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

EXTENSION OF EXAMINATION

In an attempt to better understand the origin of the possible ganglion/mass dynamic visualisation was attempted.

For these additional images a thick gel layer was applied to the wrist to maintain contact with light pressure.

Page 29: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

DYNAMIC IMAGES

Image 15: Left dorsal wrist in the region of interest in flexion.

Page 30: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

DYNAMIC IMAGES

Image 16: Left dorsal wrist in the region of interest in neural.

Page 31: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

DYNAMIC IMAGES

Image 17: Left dorsal wrist in the region of interest in neutral. An arrow is used to indicate a possible point of origin.

Page 32: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ULTRASOUND FINDINGS

Page 33: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ULTRASOUND FINDINGS

Page 34: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

DIFFERENTIAL DIAGNOSIS Ganglion or Mass

Page 35: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

GANGLIONS

Page 36: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

GANGLION Def

Aetiology

Population at increased risk

Page 37: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ULTRASOUND APPEARANCE OF GANGLION

Page 38: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ALTERNATIVE IMAGING MODALITIES MRI

Page 39: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

INTERVENTIONAL TECHNIQUES Non Invasive

Aspiration and injection Rest Bible

Invasive Surgery

Page 40: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

RADIOLOGIST IMPRESSION

Page 41: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ASPIRATION AND INJECTIONAfter a discussion with the radiologist and the patient it was decided that aspiration of the ganglia was to go ahead followed by an injection of xylocane, rupivicane and elestone.

Page 42: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

PROCEDURE PREPARATION A sterile trolley was assembled. The following was included

Sterile dressing back 2 x 3ml luerlock syringes Extension tube Drawing-up needle ___G needle

Sterile gloves were made available for the radiologist.

Page 43: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

PROCEDURE A clean environment

was established. The patient’s wrist

was positioned in slight flexion. This was achieved with a gel bottle being placed beneath the wrist covered with bluey.

Image of set up here

Page 44: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

PROCEDURE

The skin was prepped with an alcohol solution as per practice protocol.

Appropriate volumes of the drugs to be administered were decanted.

Local anaesthetic was first injected into the site and allowed to take effect.

An attempt to aspirate the suspected ganglion was made.

Page 45: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ASPIRATION

Image 18: Area of suspected ganglion. An aspiration of several areas was attempted with nil fluid extracted.

Page 46: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

PROCEDURE

As no fluid was extracted, an injection of rupivicane and celestone was administered

Page 47: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

ASPIRATION

Image 19: Area of suspected ganglion. Injection of medication.

Page 48: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

POST PROCEDURE

Page 49: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

POST PROCEDURE

The patient appeared to tolerate the procedure well.

They were informed to rest the wrist for 24-48 hours and were given post procedure care instructions as per practice protocol.

A “pain chart” was also given to the patient to record the effectiveness of the procedure.

Page 50: Case Study – Abnormal Appearing Ganglion in the dorsal wrist

REFLECTION