CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES Dr. Avinash N. Patkar Head-...

16
1 CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group The TATA Power Company Ltd. (TPC) International Workshop on Carbon Capture and Storage in Power Sector: R&D Priorities in India New Delhi, INDIA January 23, 2008

description

CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group The TATA Power Company Ltd. (TPC) International Workshop on Carbon Capture and Storage in Power Sector: R&D Priorities in India New Delhi, INDIA - PowerPoint PPT Presentation

Transcript of CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES Dr. Avinash N. Patkar Head-...

Page 1: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

1

CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE

INDUSTRIES

Dr. Avinash N. PatkarHead- Corporate Environment & Safety Group

The TATA Power Company Ltd. (TPC)

International Workshop on Carbon Capture and Storage in Power Sector: R&D Priorities in

India New Delhi, INDIAJanuary 23, 2008

Page 2: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

2

THE TATA POWER COMPANY LIMITED

Thermal Hydro Wind

1) Trombay (1,330 MW)

2) Jojobera (428 MW)

3) Belgaum (81 MW)1) Khopoli (72 MW)

2) Bhivpuri (75 MW)

3) Bhira (300 MW)

1) Supe (17 MW)

2) Nagar (45 MW)

Page 3: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

3

Energy Use and CO2 Emission Per Person

0

5

10

15

20

25

kWh per person

CO2 (tons/yr) per person

ELECTRICITY USE AND CO2 (PER CAPITA, 2005)

Page 4: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

4

AVERAGE CO2 EMISSIONS (MT/MWh)1: INDIA

Fuel Small (S) Medium (M) Large (L) S/M/L Size, MW

Coal 1.20 1.05 1.00 100/250/500

Lignite 1.32 1.23 1.28 75/125/250

N. Gas 0.43 0.42 0.43 50/75/100

1: Central Electric Authority of India Database (2006). See reference for assumptions.

Page 5: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

5

REDUCING CO2 EMISSIONS – STEPS

Prepare a CO2 and GHG Emissions Inventory.

Improve efficiency by energy audits and rehabilitating old, inefficient plants.

Higher efficiency technologies (Super-Critical and IGCC) for new plants.

Renewable energy – Hydro, wind, solar, bio-energy, ocean and geo-thermal.

Carbon Capture and Sequestration (CCS).

Page 6: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

6

PFD FOR MEA CO2 CAPTURE (CC) SYSTEM

Page 7: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

7

AMINE BASED COMMERCIAL SOLVENTS1

Supplier/ Solvent Loss, Solvent Cost Steam UsedSolvent kg/ton CO2 $/kg $/ton CO2 kg/kg CO2

Many/MEA 1.0 to 3.0 1.25 1.20 to 2.50 2.0

Fluor/MEA+ 2.0 1.50 2.30 2.3

MHI/KS-1* 0.35 3.00 1.55 1.5

1: US EPA (2006); +: With Inhibitors *: Hindered Amines

Page 8: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

8

BUDGET ESTIMATES FOR NEW PLANT (500 MW): WITHOUT CC 1,2,3

Parameter Sub Critical Super CriticalNet Thermal Eff., % 34.8 41.9 Net Heat Rate, Kcal/kWh 2,490 2,070 Coal Used tons/hr 200.7 166.9 Gross Power, MW 541 543 Capital Investment, $/ kW 1,387 1,575 COE, cents/kWh 5.2 4.3 1: Sub-bituminous coal; High Heating Value (HHV) = 4,800 kcal/kg (as received). 2: EPA, 2006: With a SCR system (NOx < 15 ppmv) and a limestone FGD (SO2 < 10 ppmv).3: Costs are + 30%, US Dollars. December 2004.

Page 9: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

9

BUDGET ESTIMATES FOR NEW PLANT (500 MW): WITH CC 1,2,3,4

Parameter Sub Critical Super CriticalNet Thermal Eff., % 26.1 31.5 Net Heat Rate, Kcal/kWh 3,110 2,590 Coal Used tons/hr 261.5 208.6 Gross Power, MW 670 673 Capital Investment, $/ kW 1,997 2,270 COE, cents/kWh 7.8 4.3 1: Sub-bituminous coal; HHV = 4,800 kcal/kg (as received). CO2 Removal = 85%.2: EPA, 2006: With a SCR system (NOx < 15 ppmv) and a limestone FGD (SO2 < 10 ppmv).3: Costs are + 30%, US Dollars. December 2004.4: IPCC, 2005 (TS.3): CC system - More energy (24%); higher capital (44%) and

higher COE (42%) than baseline. These are the lower values of a range given.

Page 10: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

10

PROBLMES WITH MEA SYSTEMS

• Degradation of MEA due to O2, SO2, NOx• Losses to flue gas and leakage: Solvent costs• High solvent regeneration energy required• Corrosion of vessels, packing, piping • High capital costs (+ ~ 44% for new) • High operating costs (+ ~ 24% for new)• High Cost of Energy (+ ~ 42% for new)• Retrofit could be almost double as expensive

Page 11: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

11

R&D WORK WITH CC SOLVENT SYSTEMS

• Solvents with higher CO2 loading (kg/kg)• Solvents that will resist O2, SO2, NOX

• Packing with higher surface area (250 m2/m3)• Packing with lower gas DP at high gas velocity

(3 m/sec) and high L/G ratio (60 m3/m2.hr)• (NH4)2CO3: Alstom and Powerspan (in USA)• K2CO3: U. of Texas, Austin, TX, USA• Penalty Targets: Energy < 10%; Cost < 20%

Page 12: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

12

PFD FOR OXY-FUEL COMBUSTION

Page 13: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

13

REVIEW OF OXY-FUEL COMBUSTION

Advantages• Concentrated SO2, NOx and CO2

• Absorption systems will be much smaller• A 30 MW demo plant is planned by Vattenfall Disadvantages• Higher energy for pure O2 than MEA system• Difficult to retrofit • Pilot scale work so far (< 1 MW)

Page 14: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

14

R&D WORK ON OXY-FUEL COMBUSTION

• More efficient membranes for pure O2 system

• More efficient adsorbents for pure O2 system

• Optimization of combustion and CC• Defined system for SO2 and NOx control• A 10 MW pilot plant is planned by B&W• A 30 MW demo plant is built by Vattenfall

Page 15: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

15

CONSTRAINTS ON CC TECHNOLOGIES: 2008

High Investment and energy

penalty

Sequestration/ReuseUncertainty

Technologies at pilot/demo scale

Regulatory uncertainty

Amine CC capital investment will be ~1.9 Crore/MW (~44% of power plant); Parasitic energy would be ~ 24% of gross output and COE will be ~42% higher as of Jan. 2008! More for Oxy-Fuel CC.

CC technologies for coal-fired power plant are in pilot (1-5 MW) or demo (10-30 MW) scale; Thus uncertainty in scale-up to 500 MW

Limited CO2 reuse in Gas/Oil/Methane Recovery; Costs of compression/liquification and transport

No global consensus, Limits long-term loans and raises interest rates: Limited global financing

Page 16: CARBON DIOXIDE CAPTURE (CC) OPTIONS FOR ENERGY INTENSIVE INDUSTRIES    Dr. Avinash N. Patkar Head- Corporate Environment & Safety Group

16

Any Questions?

For copies of this presentation, please send an e-mail to:

[email protected]