Captair 392 SmartDuctless filtering fume hoods
Productdatasheet
Safer to operate- ExclusiveErlabfiltrationtechnologycombiningactivatedcarbonandHEPA/ULPAtoadapttothemanipulation - MeetsAFNORNFX15211/ANSIZ9.5-2012filtrationefficiencystandard(class1and2)- Realtimesensorstodetectmainfiltersaturationwithsolvents,acidsorformaldehyde- Safetyfilterincaseofmainfiltersaturation - Airfacevelocitypermanentmonitoring - ErlabSafetyProgram:applicationanalysisandvalidation,usageframeworkcertification,usagefollow-up- Connecteddeviceallowingreceptionofsafetynotificationsandusestatus
Simpler to useRealtimestatuscommunicationbylightandsoundpulses:-Airfacevelocitydecrease- Mainfiltersaturation- Fanfailure- Excessscheduledworkingtime
Flexibility- Modularfiltrationcolumnadaptingtoapplicationchanges- Easyandfastrelocation
Savings- Noductworkcost- Annualenergycost<100€- Comparedtoanextractionfumecupboard,energysavings compensatefilterreplacementcost
Environment- Nochemicalreleaseintotheatmosphere- Lowenergyconsumption
Powerful light guided
communication
Ask for the highest level of
filtration performances
Connect your equipment and benefit from the
remote access thanks to our mobile solutions
Dowload our eGuard application
Captair 392 SmartDuctless Filtering Fume Hoods
Heightsaccordingtothefiltrationcolumnconfiguration
Type1Cor1P 1340mm
Please add 150mm between the last filter and the ceiling to allow a good air recirculationandtoreplacefilterseasilyType2Cor1P1Cor1C1P 1435mm
Type1P2Cor1P1C1P 1515mm
Work surfaces with built in spill tray
Benchcap: fixed work bench Mobicap : mobile rolling cart
Tempered glass Trespa® Top LabPLUS 304 L stainless steel
875 mm 855 mm
644 mm 648 mm
27 mm
585 mm
904 mm
2250 mm min 2425 mm max
88 5/8 min 95 1/2 max
2225 mm min 2400 mm max
87 5/8 min 94 1/2 max
2250 mm min 2425 mm max
88 5/8 min 95 1/2 max
2225 mm min 2400 mm max
87 5/8 min 94 1/2 max
1005 mm39 5/8
1005 mm39 5/8
960 mm37 3/4
749 mm29 1/2
273 mm10 3/4
272 mm10 11/16 564 mm
22 1/4
687 mm27
74 mm 2 7/8
1065 mm (without work surface)
41 7/8
1052 mm min (with work surface)
41 3/8
1340 mm min1515 mm max
59 5/8 max52 3/4 min
321Captair SmartHotte à filtration sans raccordementErlab’s innovative technology keeps you safe
Communicationinterface
Simple communication by audible and light pulses: unit running time, air face velocity, automatic filter saturation detection, ventilation settings, fan failure alarm
Filtration technology 2 columns that can be configured to handle liquids, powders, or both
Carbon filtration for gases and vapours Following filtration column configuration (see table above)
Particulate filtration for powders Following filtration column configuration (see table above)
eGuard APP for remote control to monitor the hood, change the settings, and deliver safety alerts immediately to your devices (mobile, tablet and PC)
Internal lighting LED lighting > 650 Lux
Anemometer Air face velocity alarm
Anemometer Air face velocity indicator
Chemical Listing List of approved chemicals
Safety Standards AFNOR NF X 15-211:2009: France - BS 7989: EnglandDIN 12 927:Germany - EN 1822:1998 (HEPA H14 & ULPA U17 Filters) - CE Marking
Air Flow 440 m3/h - 135 CFM
Air Face Velocity 0.4 to 0.6 m/s - 79 fpm to 118 fpm
Voltage/Fequency 220 V / 50-60 Hz
Power consumption 105 W
Sash openings Total openings or new reverso sash
Structure Corrosion resistant electro-galvanized steel coated with anti-acid polymer
Side and front panels Chemical resistant acrylic
Filtration module Polypropylene
Equipment
Work Surfaces Tempered glass / Trespa® Top LabPLUS / 304 L stainless steel
Molecode Detection sensor for : Type S, for solvents / Type A, for acids / Type F, for formaldehyde
Benches Mobile (Mobicap) or fixed (Benchcap)
Bench equipment Technical gases outlets, water outlets, front control valves, sink, power sockets (Only compatible with Trespa® Top Lab plus worktop and fixed bench)
Particulate Pre-filter Protects the main filter(s) from dustTransparentBack Panel Clear acrylic panel for easy viewing
Accessories
Captair 392 SmartDuctless Filtering Fume Hoods
FILTRATION TECHNOLOGY
Modular design of the filtration column allows toadapt to every protectionneeds
Carbon filtration for gases and vapoursAS:For organic vapoursBE+:Polyvalent for acid + organic vapoursF:For formaldehyde vapoursK:For ammonia vapours
Particulate filtration for powdersHEPA H14:99.995 % efficiency filtration of particles over 0.1 µm in sizeULPA U17:99.999995 % efficiency filtration of particles over 0.1 µm in size
Ventilation
MolecodeAutomatic alarm to detect filter saturation
Products handled / Applications
Liquid chemicals handlings Powders handlings Liquid chemicals and powders handlings
Liquid chemicals handlings in clean room
Cus
tom
ized
filtr
atio
n co
lum
n Class I according
to theNF X 15-211
NA
Class 2 according
to theNF X 15-211
Maximum
protection Maximum
protection Maximum
protection
P C
2C
1C 1P 1P1C
1P2C 2C1P
1C1P
Available filters :
About Erlab
France +33 (0) 2 32 09 55 80 │ [email protected]
Germany 0800 330 47 31│ [email protected]
China +86 (0) 512 5781 4085 │ [email protected]
Italy +39 (0) 2 89 00 771 │ [email protected]
Malaysia +60 (0) 7 3 555 724 │ [email protected]
Spain +34 93 673 24 74 │ [email protected]
USA+1 800-964-4434 │ [email protected]
United-Kingdom +44 (0) 1722 341 940 │[email protected]
www.erlab.com
1 R&D laboratory AworldwideuniquelabasawarranttoErlabexpertiseinfiltration.Erlabinnovatesconstantlytodesignhighestlevelof
chemicalprotectiontechnologies.
2 Safety standards OurproductsperformancesarecertifiedbycompliancewiththeAFNORNFX15211standard.
3 Independent tests Ourfiltration technologyhasbeen testedmultiple timesbyan independent laboratoryaccording toAFNORNFX15
211requirements.Resultsprovefiltersefficiencytomaintainconcentrationinrecirculatedairatlowerthan1%oftestedchemicalsTLV.
4 Chemical listing Ouruniqueknow-howenableustocommunicateonourfiltersretentioncapacitiesover700chemicals,followingAFNOR
NFX15211requirements.
5 Erlab Safety Program Oursafetyprogramisthewarrantofyourprotectionatallstages:anyprojectbeginswithanapplicationanalysistoallow
ourlabtorecommendthesuitablesolution.Allinstalledequipementsarethenfollowed-uptoguaranteethehighestlevelofprotectionovertime.
6 Our questionnaire Allows our lab specialists to recommend adapted filtration fume hood, filter type and predictive life-time, such as
personnalisedassessment.
7 We make your fume hood uses a commitment Ourlaboratoryprovidesausagecertificateforeachfumehood,incompliancewithAFNORNFX15211requirements.
ErlabOur mission: guarantee your protection in the lab
Erlabinventedthefirstfiltrationfumehoodin1968.45yearsofexpertiseinchemicalsfiltrationenableustoguaranteeyourprotectionthroughoutthefollowingaspects:
Erlab R&D laboratory
Cap
tair
Smar
t V.0
3_09
_201
6 -T
echn
ical
dat
a ar
e no
t con
tract
ual.
Erla
b re
serv
es th
e rig
ht to
mod
ify th
e pr
esen
t doc
umen
t with
out p
rior n
otic
e.