Microchannel Heat Exchanger Flow Loop
Team 16 Final Technical ReportApril 29, 2015
MECE: Capstone 2014-2015
Jeremy Evans, Olivia Pacheco, John-Roland Espinosa, Michael Russo
![Page 2: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/2.jpg)
Outline
Project BackgroundStatement of WorkDeliverables and ValidationMethodologyResults and AccomplishmentsConclusionRecommendations
![Page 3: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/3.jpg)
Introduction to Problem
http://upload.wikimedia.org/wikipedia/commons/2/25/AMD_heatsink_and_fan.jpg
http://h10025.www1.hp.com/ewfrf-JAVA/Doc/images/1003/c03904186.jpg
![Page 4: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/4.jpg)
Background
Heat flux can reach
![Page 5: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/5.jpg)
Background (make eq. more readable)
𝒇= ∆𝑷𝑫𝒉𝑳𝟎.𝟓𝝆𝑼𝟐
![Page 6: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/6.jpg)
Statement of Work
1. Create a coolant flow loop incorporating a microchannel heat exchanger to be used in MECE 4371
2. Compose a flow loop manual 3. Write two lab experiments for students to
conduct in MECE 4371 dealing with fluid and thermal theories
![Page 7: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/7.jpg)
Deliverables and Validation
A completed flow loop containing a microchannel heat exchanger
Two lab manuals incorporating the completed flow loop to be used for experiments in MECE 4371
Experimental temperature and pressure data with theoretical correlations
Coolant loop performs as specified by Dr. Liu
![Page 8: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/8.jpg)
Methodology & Process
• Research• Internet• MECE coursework• Dr. Liu’s thesis
• Analysis to determine required components and specifications
• Determine theoretical predictions, required formulas and relations
• Receive and test all ordered components• Prime the pump• Assure that voltage conversions
are safe and accurate
![Page 9: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/9.jpg)
Methodology & Process
Flow rate to remove optimal heat flux:
Pressure drop calculation from friction factor definition:
Required capability of heat cartridges in order to attain desired 100 heat flux:
![Page 10: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/10.jpg)
Methodology & Process
• Construct flow loop (precision required!!)• Determine component layout• Cut and bend steel piping• Machine G10• Build and implement fixtures for
pump, rotameter, MCHX assembly and condenser
• Configure software • Set up data acquisition multiplexer
with TC and PT connections
![Page 11: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/11.jpg)
Methodology & Process
• Run Nusselt’s Number and Friction Factor experiments and document processes
• Compare measured data for experiments with theoretical predictions and provide to client
• Document flow loop operation instructions
![Page 12: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/12.jpg)
Results/Accomplishments
1. Milestone 1 – Component Fabrication and Procurement Completed
2. Milestone 2 – Flow Loop Assembled
3. Milestone 3 – Flow Loop and Experiment Documentation
4. Milestone 4 – Final Design Validated for Client
COMPLETED
COMPLETED
COMPLETED
COMPLETED
![Page 13: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/13.jpg)
Results/Accomplishments
1. Flow Loop Constructed and Validated Show temperature and pressure data vs. flow rate,
explain the trends that were sought, etc. Show pictures of completed flow loop
2. Friction Factor Experiment and Validation Show f*Re plot with theoretical curve Show theoretical relation
3. Nusselt’s Number Experiment and Validation
Show f*Re(???) plot with theoretical curve Show theoretical relation
![Page 14: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/14.jpg)
Results/Accomplishments
Flow loop constructed
![Page 15: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/15.jpg)
Results/Accomplishments
![Page 16: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/16.jpg)
Item Cost Vendor
Gear Pump with AC Motor and Controller $1,434.00
Cole ParmerGroundwater Filter 5.0UM $47.25Turbine Flowmeter $75.00
Copper Liquid-Liquid Heat Exchanger $319.00 Lytron
Stainless Steel Reservoir $350.90McMaster-CarrT-Type Thermocouple $18.50
Stainless Steel 0.25” Piping 6 feet $19.42Swagelok fittings, control valves and
bypass$1,500.00 Swagelok
Reverse Osmosis Water $40.00Data Acquisition (DAQ) and module with
software and connections$499.00
EbayG-10 Material $51.01
Cartridge Heaters $372.00 OmegaPressure Transducers $450.00Soft insulating material (Mylar Blanket) $4.00
High temperature sealant and Locktight $9.00
Polycarbonate $12.33 US Plastic CorpStainless Steel Cart $149.33 Amazon
NPT Reducers for PT Connection $16.89 Summit Racing
TOTAL $5367.63
Results/Accomplishments (update numbers)
![Page 17: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/17.jpg)
Conclusion
Thermal management is gaining priority as the number of transistors per IC increases in modern computers.
The flow loop, its manual, and both experiment manuals have been completed and delivered to the client on time and were approved
![Page 18: capstone_final_technical_report](https://reader035.fdocuments.us/reader035/viewer/2022070509/58a3af501a28ab9e6a8b6591/html5/thumbnails/18.jpg)
Recommendations
Extensions to experiments: 2 – phase flow experiments Slug flow experiments
Improvements to flow loop: Pressure transducers with increased voltage range More accurate rotameter Different housing design – improved fit between
copper block and housing, easier manipulation of o-rings