    electricpete posted 05 May 2010 04:13 PM

    We have a 1" vent line that extends straight up from a LARGE pipe

    in a cantilever fashion.

    We see varying high vibration on the pipe up to 4 ips at a

    subsynchronous frequency approx 1500 cpm (machine operates at

    5200). I think it is flow noise. Other similar sister machine pipes

    vibrate at 0.5 ips or less.

    We added 5-7 pounds weight and magnitude came down as well asfrequency. Details attached.

    I think we are just lowering the resonant frequency below the range

    where the flow-induced excitation is highest. I realize lowering

    resonant frequency is a more logical strategy for fixed-frequency

    excitation rather than broadband, but it seems to have worked in

    thise case.

    Does it make sense to permatize weights similar to this?

    SGFP23_VentlLineSmall.ppt (958 Kb, 91 downloads)

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    Ron

    Brookposted 05 May 2010 04:28 PM Hide Post

    EP,

    Go ahead and add more weight and test it. You are adding inertia

    which will lower the displacement, but it would appear that there isalso a natural frequency involved that you are moving away from.

    Ron

    Posts: 916 | Location: Philadelphia,PA | Registered: 18 July2006

    http://maintenanceforums.com/eve/forums/a/ga/ul/801106666/SGFP23_VentlLineSmall.ppthttp://maintenanceforums.com/eve/loginhttp://maintenanceforums.com/eve/forums/a/frm/f/3751089011http://maintenanceforums.com/evehttp://maintenanceforums.com/evehttp://maintenanceforums.com/evehttp://www.reliabilityweb.com/cgi-script/csBanner/csBanner.cgi?command=click&g=709&id=905http://www.reliabilityweb.com/cgi-script/csBanner/csBanner.cgi?command=click&g=709&id=905http://www.reliabilityweb.com/cgi-script/csBanner/csBanner.cgi?command=click&g=709&id=905http://www.reliabilityweb.com/cgi-script/csBanner/csBanner.cgi?command=click&g=709&id=905http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=6211085252http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=865106666#865106666http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011http://maintenanceforums.com/eve/forums/a/ga/ul/801106666/SGFP23_VentlLineSmall.ppthttp://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=701106666#701106666http://void%280%29/http://maintenanceforums.com/eve/loginhttp://maintenanceforums.com/eve/forums/a/frm/f/3751089011http://maintenanceforums.com/eve/forums/a/cfrm/f/998103451http://maintenanceforums.com/eve/forumshttp://maintenanceforums.com/evehttp://maintenanceconference.com/cbm13/http://maintenanceforums.com/evehttp://www.reliabilityweb.com/cgi-script/csBanner/csBanner.cgi?command=click&g=709&id=905http://www.reliabilityweb.com/cgi-script/csBanner/csBanner.cgi?command=click&g=709&id=905http://twitter.com/search?q=http%3A%2F%2Fmaintenanceforums.com%2Feve%2Fforums%2Fa%2Ftpc%2Ff%2F3751089011%2Fm%2F701106666https://twitter.com/intent/tweet?original_referer=http%3A%2F%2Fmaintenanceforums.com%2Feve%2Fforums%2Fa%2Ftpc%2Ff%2F3751089011%2Fm%2F701106666%2Fp%2F1&text=cantilever%20vent%20line%20vibration%20-%20mass%20addition%3F%20-%20Topic&tw_p=tweetbutton&url=http%3A%2F%2Fmaintenanceforums.com%2Feve%2Fforums%2Fa%2Ftpc%2Ff%2F3751089011%2Fm%2F701106666http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/2
  • 7/27/2019 Cantilever Vent Line Vibration - Mass Addition_ - Topic

    2/9

    6/26/13 cantilever vent line vibration - mass addition? - Topic

    maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/1

    WaltStrong

    posted 05 May 2010 05:28 PM Hide Post

    El'Pete,

    That was a good start. A true rigid weight of 10-12 lbs might give a

    frequency redct ion over 20% (now 17%) and reduce vibration levels

    further. More weight would be needed if it was installed closer to

    valve body, so keep elevation high on stub pipe, as possible.

    Walt

    Posts: 2147 | Location: Massachusetts | Registered: 27 April2005

    electricpete posted 05 May 2010 09:14 PM Hide Post

    Thanks. We are going to clamp weight onto the pipe cap using

    device shown attached. The clamp weight around 6 pounds with

    provisions for additional weight in 3 pound increments, following

    Walt's comment. Our machinist says he will figure out the exact

    dimensions needed to get good clamping action on the pipe cap.

    We didn't try stiffening. My thought is that the initial directionwould be increase in vibration with small amount of stiffening

    (based on weight addition results), but certainly could turn back

    down as we get stiffen farther. There is not a lot to brace off of as

    you can see it sits in the air. The adjacent blue structure isremoved (during outages), so it would not be good to clamp to. If I

    had more time, I might investigate that further but we're far enough

    into weight addition that I'm going to stick with it (unless there are

    some obvious problems with this design anyone can think of).

    One the thing that makes me a little uneasy is the idea of tuning

    away from broadband flow noise. We are now a little less than full

    flow. Would frequency of flow noise be expected to change withchange in flow? How about change in fluid temperature?

    Another interesting thing is that the magnitude of the vibration

    wanders up and down. Would this type magnitude variation be atypical expected behavior for a resonance excited by broadband

    flow noise?

    This message has been edited. Last edited by: electricpete,

    05 May 2010 09:24 PM

    Clamp4a.ppt (1,136 Kb, 64 downloads)

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    Ron

    Brookposted 06 May 2010 06:58 AM Hide Post

    EP,The response of a component at resonance is always dependent on

    the amount of energy in the forcing function. The amplification factor

    doesn't change.

    If the 'broadband' energy you describe in this pipe doesn't have a

    defined flow resonance, then the amplitude of the response with

    change with % of flow.

    My guess is that there is a fluid resonance and the amount of energy

    http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=144104766#144104766http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011http://maintenanceforums.com/eve/forums/a/ga/ul/793109666/Clamp4a.ppthttp://maintenanceforums.com/eve/personal?x_myspace_page=profile&u=5301028011http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=693109666#693109666http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=7141004131http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=158107666#158107666http://void%280%29/
  • 7/27/2019 Cantilever Vent Line Vibration - Mass Addition_ - Topic

    3/9

    6/26/13 cantilever vent line vibration - mass addition? - Topic

    maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/1

    at the resonance could be affected by small changes in flow day to

    day.

    I like the design of the weights.

    Posts: 916 | Location: Philadelphia,PA | Registered: 18 July2006

    Walt

    Strongposted 06 May 2010 08:58 AM Hide Post

    El'Pete,

    An increase in flow velocity generally raises turbulence peak frequency

    and amplitude. Temperature change would probably have insignificant

    effect on structual natural frequency. I think that the add-on weight

    will be as good or better at higher flow/turbulence. The only negative

    about the weight design is that the additional weights are attached

    by bolts in shear, and this is not the strongest clamping direction. If

    you do add one or more plates to get to "magic weight" status, then

    weld the plates together and to one of the clamp halves. This would

    prevent loosening over time and reduce risk of losing parts should it be

    removed for any reason.

    Walt

    Posts: 2147 | Location: Massachusetts | Registered: 27 April2005

    electricpete posted 06 May 2010 11:08 AM Hide Post

    Thanks. Good comments.

    Now a crucially important aspect I have to describe this thing on

    paper. Everyone wants to call it a dynamic absorber, but that's not

    what it is. We all know it is a weight added to reduce resonant

    frequency. What is the short/quick catchy name for that?

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    Walt

    Strongposted 06 May 2010 11:45 AM Hide Post

    El'Pete,

    "Tuning Mass"

    "Detuning Mass"

    "NF Modifier"

    "Stubby the pacifier mass"

    "Magic Mass"

    Be aware that the valve and stub pipe may be acting like a "dynamic

    absorber" if the large pipe has a similar natural frequency. It would be

    worthwhile to inspect and/or measure vibrations at other locations in

    the pipe system to be sure that no new high vibration problems werecreated.

    Tip: Use thin SS shim stock to be sure there is a tight 2-point (each

    clamp half) contact to stub pipe.

    Walt

    Posts: 2147 | Location: Massachusetts | Registered: 27 April2005

    http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=7141004131http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=838106766#838106766http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=346106766#346106766http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=7141004131http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=359104766#359104766http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=6211085252
  • 7/27/2019 Cantilever Vent Line Vibration - Mass Addition_ - Topic

    4/9

    6/26/13 cantilever vent line vibration - mass addition? - Topic

    maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/1

    William_C._Foiles posted 06 May 2010 12:57 PM Hide Post

    Should the goal be to eliminate the branch pipe vibration or to

    just follow the pipe vibration?

    One can address the main pipe vibration separately.

    Mass can not only de-tune; it can change the mode shape.

    Regards,

    Bill

    Posts: 2545 | Location: Houston, TX USA | Registered:23 February 2005

    electricpete posted 07 May 2010 11:48 AM Hide Post

    The small pipe has enough access we could measure bottom, middle

    and top. Levels highest at top, lowest at bottm, in the middle

    between. The pattern stayed the same with our initial 5 pounds

    added mass. So I think it is 1st mode shape of cantilever beam andthe main pipe is not vibrating excessively.

    LOL - I would have liked to seen my bosses face if I wrote "magic

    mass" in my paperwork. I like "Detuning mass" - it is very short and

    descriptive, and I would've used that if I'd have thought of it or

    read it in time, but I ended up using "vibration-reducing weight"(pretty lame).

    Operations wouldn't let us attach anything to the pipe cap since

    they have to remove it for fluid system venting during every plant

    startup. So we have to clamp to the pipe below the cap rather

    than to the cap. Also we have to keep enough clearance to

    operate the valves. I had to get agreement from a pipe stress guy.He wanted to restrict the total weight added to 15 pounds and

    ensure it was symmetric about the pipe (no moment). All of this

    forced the design to evolve to what is shown in attached. It has

    minimum 5 pounds (clamp) plus provisions to add additional weightin 1.8 pound increments. Our machinists built the device yesterday.

    It may be installed today or over the weekend or Monday. Will let

    you know results.

    FinalVibrationReducingWeight.ppt (1,224 Kb, 52 downloads)

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    Steve

    Cieslaposted 07 May 2010 02:42 PM Hide Post

    At least the name you picked meets the nuclear criteria for TLA

    (Three Letter Acronymn).

    Posts: 442 | Location: Southern California | Registered: 23February 2005

    electricpete posted 08 May 2010 09:09 PM Hide Post

    lol - good point Steve.

    http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=109104076#109104076http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=1501014111http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=411109866#411109866http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011http://maintenanceforums.com/eve/forums/a/ga/ul/359107866/FinalVibrationReducingWeight.ppthttp://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=259107866#259107866http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=3911027111http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=433107766#433107766http://void%280%29/
  • 7/27/2019 Cantilever Vent Line Vibration - Mass Addition_ - Topic

    5/9

    6/26/13 cantilever vent line vibration - mass addition? - Topic

    maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/1

    The "VRW" was installed today. I was not there, but the report is

    that the full 14.5 pounds was installed all at once (didnt try any

    intermediate mass level) . The vibration reduced to 0.20 0.23 ips

    on top of the pipe in both directions at a frequency of 1145 cpm.

    Vibration remained approx 0.20 at bottom of the pipe. I have no

    report of vibration level in the middle of the pipe (will check Monday

    to try to get an idea of the shape).

    Fitting this data against SDOF model:f = C / sqrt(M0+Madded)

    Madded = 0 pounds => we had 1555 cpmMadded = 5.5 pounds => we had 1290 cpm.

    From above first two datapoints we solve C=5418 cpm*lbm^0.5 ,

    M0 = 12.14 lbm

    From the above we would predict:

    Madded = 14.5 pounds => 1050 cpm resonant freq (SDOF

    prediction)

    But we actually had

    Madded = 14.5 pounds => 1145 cpm resonant freq (actualmeasured)

    So a SDOF model does not fit very well accross this range of

    attached masses.

    This message has been edited. Last edited by: electricpete,

    08 May 2010 09:28 PM

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    William_C._Foiles posted 09 May 2010 05:08 PM Hide Post

    Often one can brace the smaller pipe to the larger one. Could

    this not be done?

    When the frequency changes a great deal and when the

    added mass is a considerable fraction of the total mass it ispossible that the mode shape has changed. The frequency

    reduction for this mode could be close to reaching a limit, i.e.

    close to the point where it would be with infinite mass

    (probably some room to go further if desired).

    Regards,

    Bill

    Posts: 2545 | Location: Houston, TX USA | Registered:23 February 2005

    roughrider posted 09 May 2010 05:44 PM Hide Post

    Reminds me of using a stabilizer on a bow, the longer the stabilizer

    the less weight required to prevent torque.

    Posts: 12 | Location: alaska | Registered: 01 March 2010

    Walt

    Strongposted 09 May 2010 07:44 PM Hide Post

    El'Pete,

    http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=935105176#935105176http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=399106595http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=858104176#858104176http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=3911027111http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=416104176#416104176http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011http://maintenanceforums.com/eve/personal?x_myspace_page=profile&u=5301028011
  • 7/27/2019 Cantilever Vent Line Vibration - Mass Addition_ - Topic

    6/9

    6/26/13 cantilever vent line vibration - mass addition? - Topic

    maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/1

    4 ips down to 0.2 ips is fantastic! The deviation from SDOF may be

    nonlinear effect of clamping the weight to the pipe as opposed to

    welding it. I think you had the right solution with the weight instead of

    bracing to the main pipe, and an infinite mass was not needed either.

    Paint it and file the results of the Case History"!

    Walt

    Posts: 2147 | Location: Massachusetts | Registered: 27 April

    2005

    William_C._Foiles posted 10 May 2010 07:58 AM Hide Post

    If you got a similar reduction in acceleration, did the force at

    the tip from inertia go down, remain the same, or go up? How

    about the dynamic moment at the intersection with the big

    pipe?

    Regards,

    Bill

    Posts: 2545 | Location: Houston, TX USA | Registered:23 February 2005

    electricpete posted 10 May 2010 10:29 AM Hide Post

    We did get a chance to take a closer look today. Vibration at

    bottom/middle/top in both direction was no more than 0.23 ips and

    no less than 0.17 ips (0.2 0.23 ips at top and 0.17 0.2 at

    bottom). We dont have a 2-channel analyser to take phase, but

    even if we did, Im not sure we would get a stable phase reading

    given the flow excitation.

    I summarized comparison of 4 configurations in attachment:

    Slide 1 original configuration 1555 cpm (1 4 ips)Slide 2 5.5 pounds weight (clamps added) 1290 cpm (0.6 1.4

    ips)

    Slide 3 [NEW] 14.5 pounds permanent weight 1145 cpm (0.17

    0.23 ips)

    Slide 4 [NEW] Sister units with different (smaller) valve style

    2300 to 2700 cpm frequency. 0.2 0.45 ips among 5 sister units

    with smaller valve (we only have one with the larger valves... the

    one that originally had the 1-4 ips vibration)

    So, I conclude the sister valves likely have 1st resonance above

    the excitation frequency, and that the flow excitation falls of

    rapidly outside of a narrow frequency band somewhere in theneighborhood of 1550 cpm to somewhere below 2300 cpm. (I would

    have thunk it would be a wider range).

    I tend to agree with Walt that the only thing left to do is the

    painting. But certainly willing to discuss and learn what we can from

    this.

    Bill as I mentioned earlier there is nothing handy to easily stiffen

    against. Certainly would be more work to try to build something like

    that. What advantage would it have been to stiffen instead of

    adding weight?

    http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=240102276#240102276http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=3911027111http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=142101276#142101276http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=7141004131
  • 7/27/2019 Cantilever Vent Line Vibration - Mass Addition_ - Topic

    7/9

    6/26/13 cantilever vent line vibration - mass addition? - Topic

    maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/1

    I dont think stresses from shear forces will be relevant since this

    resembles a long thin beam and bending stresses (from moment) are

    typically much greater than shear stresses (from shear force) in a

    long thin beam. It was our objective to reduce bending stresses

    from moment near the bottom (as Bill mentioned) where this vent

    line is welded to the main pipe which should be much larger. I tend

    to think we have accomplished that objective simply because we

    tuned obvious resonance away from the excitation, although I dont

    have means to calculate any stresses to provide proof. In the initialconfiguration we had what I believe is excitation near first resonant

    frequency where 1st mode shape is cantilever beam 1st modeshapewith highest moment and bending stresses at the base. Im not

    positive what the final mode shape looks like after weight addition,

    but my suspicion is we cannot get anywhere near the 2nd resonant

    frequency based on trying some preliminary calcs. The piping is 1

    schedule 160, i.e. 0.815 id and 1.35 od. The length from big pipe

    to tip of vent line is 23. The 1st valve is attached 8 from main

    pipe, 2nd valve is attached 19.5 from main pipe, and permanent

    14.5 weight is attached 22 from main pipe. The valves I estimated

    in the neighborhood 10-30 pounds. Thats a big range

    (uncertaintly), but anything within that range still gives us apredicted 1st resonant frequency in the very rough ballpark of our

    measurements, and predicts 2nd resonant frequency way up in theneighborhood above 6000cpm. If in fac t the 2nd mode is that high

    in frequency, then we must still be seeing a first mode shape whose

    shape is not tremendously different than the original and I dont

    think there can be enough increase in curvature to overcome the

    dramatic decrease in peak vibration magnitude (4.0 ips down to

    0.23 ips). My preliminary calcs considered the main pipe stationary.

    Will try again sometime with main pipe movement allowed (forcing

    function)... I imagine that will have some effect on the conclusion

    of how high the 2nd resonant frequency is.

    Always open to further discussion and comments.

    This message has been edited. Last edited by: electricpete,10 May 2010 11:13 AM

    PhotoComparison.ppt (3,934 Kb, 33 downloads)

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    electricpete posted 10 May 2010 07:31 PM Hide Post

    One thing you guys may have noticed... there is a gap between the

    clamp halves. We did not shim as Walt had suggested. It certainlydoesn't look right to the eye. My first thought is to wonder whether

    it will increase susceptibility of the bolts to fatigue (thinking aboutbolt joint diagram, where compression of the joint plays an

    important role). My 2nd thought, maybe the stretch in the clamp

    halves plays a similar role for this device as joint compression does

    for a typical bolted joint. What do you guys think?

    Note - if this device should fall off, there is nothing fragile below it

    and also it's not a place where people would be.

    This message has been edited. Last edited by: electricpete,

    10 May 2010 07:43 PM

    vrw.ppt (446 Kb, 26 downloads)

    http://maintenanceforums.com/eve/forums/a/ga/ul/997105276/vrw.ppthttp://maintenanceforums.com/eve/personal?x_myspace_page=profile&u=5301028011http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=897105276#897105276http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011http://maintenanceforums.com/eve/forums/a/ga/ul/340102276/PhotoComparison.ppthttp://maintenanceforums.com/eve/personal?x_myspace_page=profile&u=5301028011
  • 7/27/2019 Cantilever Vent Line Vibration - Mass Addition_ - Topic

    8/9

    6/26/13 cantilever vent line vibration - mass addition? - Topic

    maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/1

    Reply

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    electricpete posted 12 May 2010 07:44 AM Hide Post

    Heres a related quest ion. Would you consider this fix as

    permanent ?

    We require 2 barriers for the high-temperature water in the main

    pipe. The pipe cap counts as one barrier while installed. The pipecap is only removed for system venting when the system is cool

    during plant outage/startup. So we only need one of those two

    valves. We could remove one of the vent valves during the next

    plant outage (we cant do it on-line because the system is hot andwe wouldnt have isolation to cut out the valve out, short of using

    freeze seal).

    As I said, the consequence of weight falling off is not a problem.

    The consequence of vent pipe breaking at the bottom weld from

    vibration fatigue would be big problem.

    Any opinions on whether this weight should be considered

    permanent, or whether we should go to the expense/effort ofcutting out the extra valve (and updating drawings) instead?

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    electricpete posted 13 May 2010 10:19 AM Hide Post

    Thanks Sam. What are your reasons?

    fwiw - I tend to agree. There is of course one selfish reason - If

    the thing works fine forever, no-one will ever think about the

    weight or my involvement in it again. But if something goes wrong

    many years from now (lets say the year before I retire!), they willlook up the paperwork and come straight back to me.

    If I were to champion a request for design change and work order

    to cut the valve off, I would need a little more justification.

    I could say the flow excitation might change over time which could

    eventually make the weight ineffective... but if that's a concern

    than it applies to both solutions (the weight and cutting the valve).

    Although I do tend to think we would have a lot more margin above

    the existing flow excitation frequency band before we get to

    resonance with one valve cut off than we have below the existing

    flow excitation band before we get to resonance with the weight

    installed.

    Posts: 5545 | Location: Texas Gulf Coast | Registered: 20February 2005

    Powered by Social Strata Page 1 2

    Become a better predictive maintenance leader in just 3 days Join orManage Your Profile Posting Boards Asset Condition Management

    Posts About vibration/alignment/balance cantilever vent line vibration -

    mass addition?

    http://maintenanceforums.com/eve/forums/a/frm/f/3751089011http://maintenanceforums.com/eve/forums/a/cfrm/f/998103451http://maintenanceforums.com/eve/forumshttp://maintenanceforums.com/evehttp://maintenanceconference.com/cbm13/http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666/p/2http://socialstrata.com/landing/goto.php?a=evehttp://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=969101576#969101576http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011http://maintenanceforums.com/eve/forums/a/tpc/f/3751089011/m/701106666?r=763101476#763101476http://void%280%29/http://maintenanceforums.com/eve/forums?a=userposts&sortType=1&u=5301028011
  • 7/27/2019 Cantilever Vent Line Vibration - Mass Addition_ - Topic

    9/9

    6/26/13 cantilever vent line vibration - mass addition? - Topic

    maintenanceforums com/eve/forums/a/tpc/f/3751089011/m/701106666/p/1

    Contact Us | Become a better predictive maintenance leader in just 3 days | Privacy Statement | Terms of

    Service

    Copyright 2004-2013 Reliabilityweb.com All rights reserved.

    http://www.maintenanceforums.com/privacy_policy.htmhttp://maintenanceconference.com/cbm13/mailto:[email protected]