Campus-RS G.703 Interface Card

90
&DPSXV56* ,QWHUIDFH &DUG 8VHU0DQXDO CAMPUS - RS CAMPUS - RS OUT IN ALARM NC NO COM

description

Campus-RS G.703 Interface Card User Manual

Transcript of Campus-RS G.703 Interface Card

Page 1: Campus-RS G.703 Interface Card

���������� ����������� ����

����������

CAMPUS - RS

CAMPUS - RS

OUT

IN

ALARM

NC

NO

COM

Page 2: Campus-RS G.703 Interface Card

ii Campus-RS G.703 Interface Card User Manual

Copyright

July 1999

© 1999-2003 ADC DSL Systems, Inc. All Rights Reserved.

Information contained in this document is company private to ADC DSL Systems, Inc., and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of ADC.

Trademark Information

ADC is a registered trademark of ADC Telecommunications, Inc.

Campus-384, Campus-768, Campus-E1, Campus-REX, Campus-Star, and Campus-T1 are registered trademarks and Campus-RS is a trademark of ADC DSL Systems, Inc. No right, license, or interest to such trademarks is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark.

Other product names mentioned in this practice are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.

FCC Class A Compliance

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Page 3: Campus-RS G.703 Interface Card

Using This Manual

Campus-RS G.703 Interface Card User Manual iii

USING THIS MANUAL

The manual is organized as follows:

• Chapter 1 describes the product and discusses Campus-HRS™ G.703 Interface Card compatibility.

• Chapter 2 tells how to install the Campus-HRS G.703 Interface Card into either a Campus-HRS Desktop Unit or Campus-Star™ chassis (paired with a Campus-HRS Line Unit).

• Chapters 3 and 4 provide procedures on using the card to configure and monitor a Campus-HRS system.

• Chapters 5 and 6 provide reference material on viewing information and status and testing the system.

The appendices provide the following background information:

• Appendix A provides technical reference information on defaults, pinouts, and menus.

• Appendix B defines abbreviations.

• Appendix C describes the documentation set of which this manual is a part.

• Appendix D provides ADC contact information.

Page 4: Campus-RS G.703 Interface Card

Using This Manual

iv Campus-RS G.703 Interface Card User Manual

This manual documents the following versions of the ADC Campus-RS G.703 Interface Card:

CAMPUS - HRS

CAMPUS - HRS

OUT

IN

ALARM

NC

NO

COM

Campus-HRS G.703 75 OhmInterface card

Campus-HRS G.703 120 OhmInterface card

Page 5: Campus-RS G.703 Interface Card

Document Conventions

Campus-RS G.703 Interface Card User Manual v

DOCUMENT CONVENTIONS

Two types of messages, identified by icons, appear in the text, as follows:

This manual uses the following conventions:

• This font indicates text that appears on the LCD or terminal.

• Keycaps, such as , indicate keys that you press on the terminal keyboard.

• Key names in bold font indicate buttons on the desktop unit or line unit that you press.

For a list of abbreviations used in this manual, see Appendix B.

UNPACK AND INSPECT THE SHIPMENT

Upon receipt of the shipment:

1 Unpack the card and inspect it for signs of damage. If it has been damaged in transit, report the extent of the damage to the transportation company and to ADC immediately. Order replacement equipment if necessary.

2 Compare the contents of the package against the packing list to ensure a complete and accurate shipment. If the shipment is incomplete or incorrect, contact ADC as described in Appendix D.

If you need to store the unit for several days or more before installing it, return it to the original packaging.

Notes contain information about special circumstances.

Cautions indicate the possibility of personal injury or equipment damage.

ENTER

Page 6: Campus-RS G.703 Interface Card

Unpack and Inspect the Shipment

vi Campus-RS G.703 Interface Card User Manual

Page 7: Campus-RS G.703 Interface Card

Table of Contents

Campus-HRS G.703 Interface Card User Manual vii

TABLE OF CONTENTS

Chapter 1: About the Product_________________________1-1

Chapter 2: Installing the Campus-HRS G.703Interface Card____________________________2-1

Campus-Star Installation ..................................................................... 2-1

Installing the Campus-RS G.703 Interface Card into a Campus-Star Chassis .....................................................2-1

Installing a Campus-HRS Line Unit into a Campus-Star Chassis .....................................................2-3

Campus-HRS Desktop Unit Installation ............................................. 2-4

Installing a Campus-RS G.703 Interface Card into a Campus-HRS Desktop Unit........................................... 2-4

Connecting a Campus-HRS Desktop Unit to an HDSL Line..................................................................... 2-5

Connecting the G.703 Cable ............................................................... 2-5

Connecting the Alarm Relay ............................................................... 2-7

Chapter 3: Configuring and Monitoring through the LCD _________________________________3-1

The LCD Menu Buttons ......................................................................3-1

Restoring the System to Default Values.............................................. 3-3

Configuring as a Master or Slave Unit ................................................3-3

Viewing and Configuring Alarms ....................................................... 3-4

Viewing Alarm Status from the Front Panel LEDs ..............3-5

HDSL Alarms ....................................................................... 3-6

Viewing and Configuring Local Alarms...............................3-9

Viewing and Configuring Remote Alarms ........................... 3-9

Viewing Data Port Status .................................................................. 3-10

Page 8: Campus-RS G.703 Interface Card

Table of Contents

viii Campus-HRS G.703 Interface Card User Manual

Configuring Loopbacks .....................................................................3-11

Setting a Loopback Timeout ...............................................3-12

Terminating All Loopbacks.................................................3-12

Viewing Product Information ............................................................3-13

Chapter 4: Configuring through an ASCII Terminal (Console) _________________ 4-1

Connecting to an ASCII Terminal .......................................................4-1

Logging On and Off.............................................................................4-4

Logging Onto a Local Campus Unit .....................................4-4

Logging Onto a Remote Campus Unit ..................................4-5

Logging Off from a Campus Unit .........................................4-7

Using the Terminal Menus ..................................................................4-8

Restoring the System to Default Values ..............................................4-9

Configuring as a Master or Slave Unit ..............................................4-11

Viewing and Configuring Alarms......................................................4-14

HDSL Errored Seconds (ES) Alarm Threshold ..................4-15

HDSL Margin Alarm Threshold .........................................4-16

Alarm on Local Interface Loss of Signal ............................4-16

Alarm on Remote Interface Loss of Signal .........................4-16

Entering System Information.............................................................4-17

Setting the Time and Date ...................................................4-18

Changing a Password ..........................................................4-19

Changing the Unit ID and the Circuit ID ............................4-20

Configuring Loopbacks .....................................................................4-21

Initiating a Loopback...........................................................4-22

Terminating All Loopbacks.................................................4-23

Setting a Loopback Timeout ...............................................4-23

Page 9: Campus-RS G.703 Interface Card

Table of Contents

Campus-HRS G.703 Interface Card User Manual ix

Chapter 5: Using an ASCII Terminal to View Information and Status ____________________5-1

Monitoring HDSL Performance.......................................................... 5-2

24-Hour HDSL Performance History ................................... 5-4

Seven-Day HDSL Performance History...............................5-5

Viewing Local Alarm History .............................................. 5-6

Viewing Product Information.............................................................. 5-7

Viewing Data Port Status .................................................................... 5-8

Chapter 6: Testing the System ________________________6-1

Types of Loopbacks ............................................................................6-1

Local to Local Loopback ...................................................... 6-2

Remote to Local Loopback................................................... 6-3

Local to Remote Loopback................................................... 6-3

Remote to Remote Loopback................................................6-3

Terminating Loopbacks....................................................................... 6-4

Clearing Loopbacks Manually .............................................. 6-4

Loopback Timeout ................................................................ 6-4

Appendix A: Technical Reference _____________________ A-1

Technical Specifications..................................................................... A-1

Default Settings .................................................................................. A-1

Pinouts ................................................................................................ A-2

LCD Menu Reference ........................................................................ A-3

ASCII Terminal Menu Reference ...................................................... A-5

Appendix B: Abbreviations __________________________ B-1

Appendix C: The Documentation Set __________________ C-1

Page 10: Campus-RS G.703 Interface Card

Table of Contents

x Campus-HRS G.703 Interface Card User Manual

Appendix D: Technical Assistance _____________________D-1

Index _________________________________________ Index-1

Page 11: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual 1-1

1ABOUT THE PRODUCT

The ADC Campus™ G.703 Interface Card provides a connection between a High-bit-rate Digital Subscriber Line (HDSL) and a network or other digital equipment to transport digitized voice, data, and video signals over existing copper wire at an E1 rate.

There are two versions of the Campus-RS G.703 Interface Card. The first provides a 75-ohm unbalanced coaxial interface, the other provides a 120-ohm balanced twisted pair interface. With both versions, the card:

• provides a full E1 (2048 kbps) data payload transfer rate

• uses HDB3 line coding

• must derive clock source through the input data signal from the host equipment

The Campus-RS G.703 Interface Card installs into one of the following to create a Campus-RS system:

• Campus-Star chassis, along with a Campus-RS Line Unit

• Campus-RS Desktop Unit

The Campus-RS G.703 Interface Card must be installed in a Campus-RS Desktop Unit or with a Campus-RS Line Unit. It cannot be installed in an older Campus desktop unit or with an older Campus line unit.

Page 12: Campus-RS G.703 Interface Card

Chapter 1: About the Product

1-2 Campus-RS G.703 Interface Card User Manual

When mated with a Campus-RS Desktop Unit or Campus-RS Line Unit, the Campus-RS G.703 Interface Card is compatible, over the HDSL link, with another Campus-RS unit, as shown in the following illustration.

The Campus-RS G.703 Interface Card supports only a Standard Mode E1 rate. To connect the Campus-RS G.703 Interface Card to a different Campus-HRS product, you must set the following configuration options on the remote interface card:

● Set the HDSL Operating Mode to Standard Mode

● Set the Standard Mode HDSL Rate to E1.

See the remote interface card user manual to set these configuration options.

The Campus-RS G.703 Interface Card is also compatible, over the HDSL link, with the Campus-E1®, as in the following illustration.

Since the Campus-E1 unit is already set to operate at a Standard Mode E1 rate, no adjustment to the HDSL rate is necessary for this application.

Campus-Interface

RSCard,

e.g., FractionalV.35 or REX

Campus-RS Line Unitor Desktop Unit

Campus-RS Line Unitor Desktop Unit

HDSLCampus-RS

G.703 InterfaceCard

Campus-RSG.703 Interface

Card

Campus E1Interface Card

CampDesktop Unit

us-RS LineUnit or

Campus E1Line Unit or Desktop Unit

HDSL

Page 13: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual 2-1

2INSTALLING THE

CAMPUS-HRS G.703INTERFACE CARD

You can install the Campus-RS G.703 Interface Card into either the Campus-Star™ (in conjunction with a Campus-RS Line Unit) or the RS Desktop Unit.

CAMPUS-STAR INSTALLATION

The following sections describe how to install the Campus-RS G.703 Interface Card and a Campus-HRS Line Unit into a Campus-Star chassis.

Installing the Campus-RS G.703 Interface Card into a Campus-Star Chassis

Make sure you install the Campus-RS G.703 Interface Card into a Campus-Star chassis (with a Campus-RS Line Unit) or a Campus-RS Desktop Unit. The card will not operate if it is installed in an earlier version of these Campus products. For details on compatibility, see page 1-2.

Before installing the Campus-RS G.703 Interface Card, make sure there is no line unit installed in the corresponding slot on the front of the Campus-Star chassis. The card is not hot-swappable. Installing the card with a corresponding line unit installed may damage the card, the line unit, or both.

Page 14: Campus-RS G.703 Interface Card

Chapter 2: Installing the Campus-HRS G.703 Interface Card

2-2 Campus-RS G.703 Interface Card User Manual

1 Slide the card into the guide rails in the desired slot on the rear of the Campus-Star chassis.

2 Gently press the card into place until it is seated firmly in the rear connector.

3 Use the two screws on the card to secure it into place.

4 Continue with “Installing a Campus-HRS Line Unit into a Campus-Star Chassis.” The Campus-RS G.703 Interface Card will not operate without a Campus-HRS Line Unit installed in the corresponding slot on the front of the Campus-Star chassis.

2

620

DSX

-1/T

CFG

DSX

-162

0D

SX-1

/TC

FG

DSX

-1

Campus-RS G.703Interface card

Campus-Star chassis

Page 15: Campus-RS G.703 Interface Card

Campus-Star Installation

Campus-RS G.703 Interface Card User Manual 2-3

Installing a Campus-HRS Line Unit into a Campus-Star Chassis

1 If the HDSL cabling is not already connected, connect the HDSL, according to the instructions in the Campus-Star User Manual.

2 Make sure that the retaining latch is pulled completely forward and down.

3 Slide the Campus-HRS Line Unit into the front Campus-Star slot that corresponds to the slot into which you installed the Campus-RS G.703 Interface Card. Use the guide rails to align the card.

4 Gently press the card in until it is seated firmly in the rear connector.

5 Push the retaining latch in until it snaps into place. With the Campus-Star power on, the Campus-HRS Line Unit performs a power-on test and the HDSL LED flashes red.

6 Continue with “Connecting the G.703 Cable” on page 2-5.22

Install the Campus-RS G.703 Interface Card before the Campus-HRS Line Unit. Installing the card with the Campus-HRS Line Unit already installed may damage the card, the line unit, or both.

Page 16: Campus-RS G.703 Interface Card

Chapter 2: Installing the Campus-HRS G.703 Interface Card

2-4 Campus-RS G.703 Interface Card User Manual

CAMPUS-HRS DESKTOP UNIT INSTALLATION

The following sections describe how to install the Campus-RS G.703 Interface Card into a Campus-HRS Desktop Unit.

Installing a Campus-RS G.703 Interface Card into a Campus-HRS Desktop Unit

1 Slide the card into the guide rails at the rear of the desktop unit.

2 Gently press the card in until it is seated firmly in the rear connector.

3 Use the two screws on the card to secure it into place.

4 Continue with “Connecting a Campus-HRS Desktop Unit to an HDSL Line.”

2

Turn off the power to the desktop unit before you install the Campus-RS G.703 Interface Card. Installing the card with the power on may cause damage to the desktop unit, the card, or both.

CAMPUS-RS

CONSOLE

LINE

Guide rail

Campus-RS G.703Interface Card

Campus-RSDesktop Unit chassis

120 VAC@60Hz

or 220 VAC@50Hz

.2A Max

CAMPUS - RS

OUT

IN

ALARM

NC

NO

COM

Page 17: Campus-RS G.703 Interface Card

Connecting the G.703 Cable

Campus-RS G.703 Interface Card User Manual 2-5

Connecting a Campus-HRS Desktop Unit to an HDSL Line

1 If you need to install and configure the Campus-HRS Desktop Unit, see the user manual that came with the Campus-HRS Desktop Unit.

2 Connect one end of the HDSL cable to the appropriate connection (wall jack or terminal block, for example).

3 Plug the other end of the HDSL cable into the RJ-45 Line port on the rear of the Campus-HRS Desktop Unit.

4 Continue with “Connecting the G.703 Cable.”2

CONNECTING THE G.703 CABLE

1 Do one of the following:

• For the 75-ohm card, connect the Out port to the host Receive Data port and the In port to the host Transmit data port.

120 VAC@60Hz

or 220 VAC@50Hz

.2A Max

G.703 Tx datacable

G.703 Rx data cable

CAMPUS - RS

OUT

IN

ALARMNC

NO

COM

Page 18: Campus-RS G.703 Interface Card

Chapter 2: Installing the Campus-HRS G.703 Interface Card

2-6 Campus-RS G.703 Interface Card User Manual

• For the 120-ohm card, use a cable designed to the pinouts in “Pinouts” on page 1-2 to connect the Campus-RS G.703 Interface Card to the host equipment.

2 Continue with “Connecting the Alarm Relay.”

120 VAC@60Hz

or 220 VAC@50Hz

.2A Max

Campus-HRS desktop chassis

G.703 Cable

Host equipment

CAMPUS RS

Page 19: Campus-RS G.703 Interface Card

Connecting the Alarm Relay

Campus-RS G.703 Interface Card User Manual 2-7

CONNECTING THE ALARM RELAY

The Campus-RS G.703 Interface Card supports an alarm relay connection. If a major alarm or enabled minor alarm is active, this relay closes. This provides a connection for an audible or visible alarm to the card that notifies users when alarms occur. The relay remains closed until the alarm condition is cleared or (minor alarm only) the alarm is acknowledged. (See the Campus-HRS Desktop Unit User Manual or Campus-HRS Line Unit User Manual for instructions on acknowledging minor alarms.)

The alarm relay connection is provided as follows:

• For the 75-ohm card, the Common (C), Normally Open (NO), and Normally Closed (NC) alarm relay contacts are provided by the terminal block connection on the card.

• For the 120-ohm card alarm relay connection, see “Pinouts” on page 1-2.

See Chapter 3 or Chapter 4 to configure the Campus-HRS system.

Page 20: Campus-RS G.703 Interface Card

Chapter 2: Installing the Campus-HRS G.703 Interface Card

2-8 Campus-RS G.703 Interface Card User Manual

Page 21: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual 3-1

3CONFIGURING AND

MONITORING THROUGHTHE LCD

This chapter describes how to set and view the Campus-RS G.703 Interface Card system information using the LCD and menu buttons located on the front of either the Campus Management Unit (CMU) installed in the Campus-Star chassis or the Campus-HRS Desktop Unit.

You can also perform these functions through an ASCII terminal (or PC with terminal emulation software). The ASCII terminal connects to the console port either on the Campus-HRS Desktop Unit or on the Campus-HRS Line Unit installed in the Campus-Star chassis. To use an ASCII terminal to set configuration options, see Chapter 4. To view system and status information through an ASCII terminal, see Chapter 5.

THE LCD MENU BUTTONS

Use the LCD and menu buttons on the desktop unit or CMU to navigate the menus and configure the Campus-HRS system, which is defined on page 1. The following illustration shows the menu buttons on the desktop unit. See the Campus-Star User Manual for the location of the menu buttons on the CMU.

Next

Enter

Escape

CAMPUS RS

HDSL

Test

Port

LCD Menu buttons

Page 22: Campus-RS G.703 Interface Card

Chapter 3: Configuring and Monitoring through the LCD

3-2 Campus-RS G.703 Interface Card User Manual

The following table describes how to use the menu buttons to move through the LCD menus and to select items.

This manual provides instructions for viewing individual configuration options. The basic procedure is as follows:

1 Press Escape several times until CAMPUS HRS I/F: G.703 displays.

2 Press Next until the desired menu name displays, for example:

HDSL LINK CONFIG & STATUS

3 Press Enter to access the menu options, for example:

OPERATING MODE

4 Press Next until the desired option name displays, for example:

XCVR MODE

5 Press Enter to access the settings for the option, for example:

MASTER

6 Press Next until the desired setting displays, for example:

SLAVE

7 Do one of the following:

● Press Enter to save the desired option, for example:

XCVR MODE = SLAVE

● Press Escape if you do not want to save the change.

See “LCD Menu Reference” on page 3 for a map of the LCD menu structure.3

Press this button... To do this...

Next Scroll to the next LCD menu or option at the same level of the menu structure.

Enter Select the displayed LCD menu or option.

Escape Return to the previous LCD menu selection.

Page 23: Campus-RS G.703 Interface Card

Restoring the System to Default Values

Campus-RS G.703 Interface Card User Manual 3-3

RESTORING THE SYSTEM TO DEFAULT VALUES

You can restore all configuration options to their factory default values. This is an easy way to remove undesired configurations that you may have set and want to return to their default settings.

To return the configuration options to their factory default values:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Enter. The software revision and the software checksum display, as in the following example:

S/W REV: 4.2jS/W CKSUM: 3DC3

3 Press Next until Press ENTER to factory reset displays, then press Enter. The system configuration options return to the default values listed in “Default Settings” on page 1. The display returns to:

CAMPUS HRS I/F: G.703

CONFIGURING AS A MASTER OR SLAVE UNIT

The Transceiver Mode option determines the hierarchy of the two Campus-HRS units when they are attempting to establish an HDSL link.

The Transceiver Mode option has three settings: Auto, Master, and Slave. The default is Auto.

• If the local unit is set to Master, it initiates the HDSL link. The remote unit must then be set to Slave or Auto.

• If the local unit is set to Slave, it waits for the remote unit to initiate the HDSL link. The remote unit must then be set to Master or Auto.

• If a unit is set to Auto (default), it automatically switches between Master and Slave until the HDSL link is established. The setting of the other Campus unit is irrelevant.

Unless you have an important reason for doing otherwise, leave the Transceiver Mode option set to Auto.

Page 24: Campus-RS G.703 Interface Card

Chapter 3: Configuring and Monitoring through the LCD

3-4 Campus-RS G.703 Interface Card User Manual

If you must change the Transceiver Mode, use the following procedure:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until HDSL LINK CONFIG & STATUS displays, then press Enter. OPERATING MODE displays.

3 Press Next until XCVR MODE displays, then press Enter to see the currently selected option.

4 Press Next to scroll through the Transceiver Mode options until the desired setting (Auto, Master, or Slave) displays.

5 Press Enter to select the displayed setting. The LCD displays XCVR MODE and shows the new setting, for example:

XCVR MODE = Auto3

VIEWING AND CONFIGURING ALARMS

To determine if there is an active alarm condition:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until ALARM CONFIG & STATUS displays.

3 Press Enter to display the current alarm status. Any of the following three indicators can appear under CURRENT ALARMS:

● HDSL: indicates an HDSL alarm

● LOC: indicates a local alarm.

● REM: indicates a remote alarm.

If a specific indicator does not display, there is no alarm in that area of the system.

Page 25: Campus-RS G.703 Interface Card

Viewing and Configuring Alarms

Campus-RS G.703 Interface Card User Manual 3-5

Viewing Alarm Status from the Front Panel LEDs

The HDSL and port LEDs on the front panel show the alarm conditions for the respective interfaces, as in the following table.

LED Status Indication

HDSL

Solid green The HDSL link is active with no alarms.

Flashing green The HDSL is attempting to activate.

Flashing red The HDSL link is down, which is a major alarm condition.

Solid red Either the link ES threshold or the margin threshold has been exceeded, both of which are minor alarm conditions (see “Configuring Alarm Thresholds” on page 6).

Port

Solid green No alarms on the G.703 port.

Solid red A minor alarm condition, which can be one of the following:● a Loss of Signal (LOS) condition on the G.703 port● a LOS condition on the remote Campus unit’s data port.

Page 26: Campus-RS G.703 Interface Card

Chapter 3: Configuring and Monitoring through the LCD

3-6 Campus-RS G.703 Interface Card User Manual

HDSL Alarms

This section describes how to view and configure alarms on the HDSL line.

Viewing Current Alarms

If the CURRENT ALARMS display indicates an HDSL alarm, you can determine the alarm type:

1 At the CURRENT ALARMS display, press Next until HDSL LINK ALARMS CONFIG & STATUS displays.

2 Press Enter to display the current status of the three alarms, as in the following example:

LINK ES MARGIN

on off off

● LINK shows whether the HDSL link is on or off.

● ES shows whether the Errored Seconds (ES) threshold has been exceeded on the local or remote unit, or both.

● MARGIN shows whether the margin threshold has been exceeded on the local or remote unit, or both.

Configuring Alarm Thresholds

HDSL alarm thresholds determine the level at which an alarm condition is reached:

• Link ES threshold determines the number of errored seconds that must occur within a 15-minute period to trigger an alarm. You can set this threshold to 17 or 170 errored seconds, or you can disable this alarm.

• Margin threshold determines the Signal-to-Noise Ratio (SNR) margin, in dB, that must occur to trigger an alarm.You can set this threshold anywhere between 1 dB and 25 dB, in 1 dB increments, or you can disable this alarm.

Page 27: Campus-RS G.703 Interface Card

Viewing and Configuring Alarms

Campus-RS G.703 Interface Card User Manual 3-7

To set the HDSL link alarm thresholds:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until ALARM CONFIG & STATUS displays.

3 Press Enter to display the current alarm status (HDSL, LOC, or REM).

4 At the CURRENT ALARMS display, press Next. The HDSL Link alarm banner displays:

HDSL LINK ALARMS CONFIG & STATUS.

5 Press Enter to display the current HDSL alarm status, for example:

LINK ES MARGIN

on off off

6 Press Next to display the HDSL ES THRESHLD menu. Depending on the setting, the display will be one of the following:

• HDSL ES THRESHLD = Disabled

• HDSL ES THRESHLD = 17

• HDSL ES THRESHLD = 170

7 Press Enter to access the settings for the ES threshold, then press Next to scroll through the settings until the desired setting displays (Disabled, 17, 170).

8 Press Enter to select the desired setting. HDSL ES THRESHLD displays with the current setting.

9 Press Next. MARGIN THRESHOLD displays.

10 Press Enter to access the settings for the margin threshold, then press Next to scroll through the settings until the desired setting displays (1 dB through 25 dB, in 1 dB increments, or Disabled).

11 Press Enter to select the desired setting. MARGIN THRESHLD displays the number of dB that, once reached, will trigger an alarm.

The Link alarm cannot be configured or disabled. It is always enabled.

Page 28: Campus-RS G.703 Interface Card

Chapter 3: Configuring and Monitoring through the LCD

3-8 Campus-RS G.703 Interface Card User Manual

Viewing 24-Hour HDSL Alarm History

You can view the number of HDSL alarm conditions that have occurred over the past 24 hours, the time the counter was last cleared, and provides the means for you to clear the counter. The LCD displays 24-hour information for the following alarms:

● Local Errored Seconds (LOCAL ES)

● Remote Errored Seconds (REMOTE ES)

● Local UnAvailable Seconds (LOCAL UAS)

● Remote UnAvailable Seconds (REMOTE UAS)

To view the HDSL alarm history:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until HDSL LINK CONFIG & STATUS displays, then press Enter.

3 Press Next until PERFORMANCE STATUS displays, then press Enter. The LCD displays the first alarm history option:

LOCAL ES (24HR)

4 Press Next to scroll through the alarm history displays. You do not set options. This is a status display. You can clear the error counter at any time. In this way, you are setting a new baseline time from which to begin counting alarms and you are clearing all previous history.

5 To clear the counter, press Next until the LCD displays:

Press ENTER to clear error cnts

6 Press Enter. The display returns to the previous menu:

PERFORMANCE STATUS3

Page 29: Campus-RS G.703 Interface Card

Viewing and Configuring Alarms

Campus-RS G.703 Interface Card User Manual 3-9

Viewing and Configuring Local Alarms

Loss of Signal (LOS) alarms can occur on the local data port. This section describes how to view and configure this alarm:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until ALARM CONFIG & STATUS displays, then press Enter. CURRENT ALARMS displays.

3 Press Next until LOCAL I/F ALARMS CONFIG & STATUS displays.

4 Press Enter. CURRENT LOCAL ALM displays with its current status (None or LOS).

5 Press Next. LOSS OF SIG displays with its current status (Disabled or Enabled).

6 Press Enter. The current LOS alarm setting for the port (Enabled, or Disabled) displays.

7 Press Next to display the desired setting.

8 When the desired setting is displayed, press Enter to select it.3

Viewing and Configuring Remote Alarms

Loss of Signal (LOS) alarms can occur on the remote unit. This section describes how to view and configure this alarm:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until ALARM CONFIG & STATUS displays, then press Enter. CURRENT ALARMS displays.

3 Press Next until the LCD displays the Remote Interface Alarms Configuration and Status menu (RMT I/F ALARMS CONFIG & STATUS).

4 Press Enter. CURRENT RMT ALM displays with its current status (None or LOS).

Page 30: Campus-RS G.703 Interface Card

Chapter 3: Configuring and Monitoring through the LCD

3-10 Campus-RS G.703 Interface Card User Manual

5 Press Next. RMT LOSS OF SIG displays with its current status (Disabled or Enabled).

6 Press Enter. The current LOS alarm setting for the port (Enabled, or Disabled) displays.

7 Press Next to display the desired setting.

8 When the desired setting is displayed, press Enter to select it.3

VIEWING DATA PORT STATUS

You can use the LCD to view the following data port status information:

● BPV seconds: the number of seconds (from 0 to 99,999) in which at least one bi-polar violation has occurred on the G.703 interface since startup or since the counter was last cleared.

● G.703 UAS count: the number of seconds (from 0 to 99,999) that either a bi-polar violation or a Loss of Signal (LOS) indication has occurred on the G.703 interface since startup or since the counter was last cleared. This count is unique from the HDSL UAS count.

● AIS signal: the activity status (None or Active) of the AIS signal.

To view this information:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until DATA PORT STATUS displays.

3 Press Enter. BPV Seconds displays.

4 Press Next to scroll through the remaining status displays.3

Page 31: Campus-RS G.703 Interface Card

Configuring Loopbacks

Campus-RS G.703 Interface Card User Manual 3-11

CONFIGURING LOOPBACKS

Loopbacks provide a way to test the data communication path between the Campus unit, the remote unit, and the remote host equipment. The Campus-RS G.703 Interface Card supports the following loopbacks:

• Local to Local Interface

• Remote to Local Interface

• Local to Remote Interface

• Remote to Remote Interface

Chapter 6 is a description of these loopbacks.

Once a loopback condition has been initiated, it remains in effect until cleared. You may set a loopback timeout to clear the loopback automatically after a set period of time has elapsed. The default timeout is 20 minutes.

To manage loopbacks through the Diagnostics menu:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

Press Next until DIAGNOSTICS displays, then press Enter. LOOPBACK MODE displays, with the current condition of the loopback (None, Local to Local, Remote to Local, Local to Remote, or Remote to Remote).

2 Press Enter.

3 Press Next to scroll through the loopback options.

4 At the desired loopback setting, press Enter to select the option.3

Page 32: Campus-RS G.703 Interface Card

Chapter 3: Configuring and Monitoring through the LCD

3-12 Campus-RS G.703 Interface Card User Manual

Setting a Loopback Timeout

The loopback timeout determines the amount of time before a loopback clears automatically. You can choose among the following settings: 20 minutes (default), 60 minutes, 120 minutes, or None (this disables the loopback timeout).

To set a loopback timeout:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until DIAGNOSTICS displays, then press Enter. LOOPBACK MODE displays.

3 Press Next until LOOPBACK TIMEOUT displays.

4 Press Enter to access the loopback timeout options (20, 60, 120, or None).

5 Press Next to scroll through the options until the desired setting appears.

6 Press Enter to select the option and return to the LOOPBACK TIMEOUT display.

3

Terminating All Loopbacks

To terminate (clear) all loopback conditions:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Next until DIAGNOSTICS displays, then press Enter.

3 To display the loopback setting options, press Enter.

4 Press Next to scroll through the options until None is displayed.

5 Press Enter to clear the loopback.3

If you set the loopback timeout to None, loopbacks run until you clear them manually or turn the unit off.

Page 33: Campus-RS G.703 Interface Card

Viewing Product Information

Campus-RS G.703 Interface Card User Manual 3-13

VIEWING PRODUCT INFORMATION

Through the LCD menu you can view the following product information (with the option name in parentheses):

• firmware version and PROM checksum (S/W REV and S/W CKSUM)

• hardware configuration information (H/W CONFIG)

• local unit identity (LOCAL UNIT ID)

• remote unit identity (REMOTE UNIT ID)

• remote interface card (REMOTE I/F)

• circuit identity (CIRCUIT ID)

You cannot change this information through the LCD. Use an ASCII terminal to set these options. See “Entering System Information” on page 17.

To view the system information:

1 Press Escape until CAMPUS HRS I/F: G.703 displays.

2 Press Enter to view the software version and checksum information.

3 Press Next to scroll through the remaining options.

Page 34: Campus-RS G.703 Interface Card

Chapter 3: Configuring and Monitoring through the LCD

3-14 Campus-RS G.703 Interface Card User Manual

Page 35: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual 4-1

4CONFIGURING THROUGH

AN ASCII TERMINAL(CONSOLE)

You can use an ASCII terminal (console) or PC with terminal emulation software to configure Campus-HRS system options and generate system reports. The ASCII terminal connects to the console port either on the Campus-HRS Desktop Unit or on the Campus-HRS Line Unit installed in the Campus-Star chassis.

This chapter describes how to set and view the individual configuration options through an ASCII terminal. To use an ASCII terminal to view system performance and other status information, see Chapter 5.

You can perform these functions through the LCD on the front of either the Campus-HRS Line Unit installed in the Campus-Star or the Campus-HRS Desktop Unit, see Chapter 3.

CONNECTING TO AN ASCII TERMINAL

To connect the Campus-HRS Line Unit or Desktop Unit to an ASCII terminal:

1 Do one of the following:

• If the ASCII terminal provides an RJ48 jack, plug the console cable into the ASCII terminal jack.

• Otherwise, plug the console cable into the adapter, then plug the adapter into the standard 9-pin COM port on the ASCII terminal and tighten the attached screws until they are snug.

Page 36: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-2 Campus-RS G.703 Interface Card User Manual

2 Do one of the following:

● lug the other end of the console cable into the console port on the desktop unit.

ASCII terminal

9-pin COM port

120 VAC@60Hz

or 220 VAC@50Hz

.2A Max

Campus-RSDesktop chassis

Console port

ConsoleCable

CAMPUS - RS

OUT

IN

ALARM

NC

NO

COM

Page 37: Campus-RS G.703 Interface Card

Connecting to an ASCII Terminal

Campus-RS G.703 Interface Card User Manual 4-3

● Plug the other end of the console cable into the RS-232 port on the front of the line unit, as in the following figure.

3 Configure the ASCII terminal to the following communications settings:

● 9600 baud

● no parity

● 8 data bits

● 1 stop bit

● no hardware flow control4

CMU-710

POWER

MANAGEMENT UNIT

RESET

ALARMSMAJORMINORACO

SLOT

Campus RSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Campus RSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Campus RSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Campus HRSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Campus RSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Campus HRSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Campus RSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Campus RSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Campus RSLINE UNIT

HDSL

TEST

PORT

RS-232CONSOLE

Cable

ASCII terminal

Campus-Star chassis

9-pin COMport

Page 38: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-4 Campus-RS G.703 Interface Card User Manual

LOGGING ON AND OFF

Through the terminal menus, you can:

● log onto a local or remote Campus-RS G.703 Interface Card HRS system

● log off a local or remote Campus-RS G.703 Interface Card HRS system

● log onto a remote Campus unit that is not a Campus-RS G.703 Interface Card unit (for configuration options, see the user manual for the interface card that is installed in the remote unit)

Logging Onto a Local Campus Unit

To log onto a local Campus unit:

1 Press the on the ASCII terminal keyboard several times until the baud rate is established and the Logon Password screen displays on the terminal monitor.

SPACEBAR

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 00:01:43

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

LOGIN PASSWORD >

Page 39: Campus-RS G.703 Interface Card

Logging On and Off

Campus-RS G.703 Interface Card User Manual 4-5

2 Press to log on. If you have changed the password, type your password, then press to display the Main Menu.

If the system does not respond when you attempt to log on, make sure that hardware flow control is turned off on the ASCII terminal.

4

Logging Onto a Remote Campus Unit

To log onto a remote Campus unit:

1 Press the on the ASCII terminal keyboard several times until the baud rate is established and the Login Password screen displays on the terminal monitor.

2 Press to log on. If you have changed the password, type your password, then press to display the Main Menu.

The left side of the menu header indicates the Local Unit ID and the Remote Unit ID:

�����

�����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:02:33

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

MAIN MENU

1) SYSTEM STATUS

2) DATA PORT STATUS

3) SYSTEM SETTINGS

4) DIAGNOSTICS

5) REMOTE LOGON

(L)ogout

ENTER CHOICE>

�������

�����

�����

Page 40: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-6 Campus-RS G.703 Interface Card User Manual

3 Press for Remote Logon, then press .

The menu header changes to indicate the Remote Unit ID as the local unit and the Local Unit ID as the remote unit.

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:02:38

Local Unit ID: Local HRS Unit #17 Local I/F: G.703

Remote Unit ID: Remote HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

MAIN MENU

1) SYSTEM STATUS

2) DATA PORT STATUS

3) SYSTEM SETTINGS

4) DIAGNOSTICS

5) REMOTE LOGON

(L)ogout

ENTER CHOICE>

�����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:02:44

Local Unit ID: Remote HRS Unit #17 Local I/F: G.703

Remote Unit ID: Local HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

MAIN MENU

1) SYSTEM STATUS

2) DATA PORT STATUS

3) SYSTEM SETTINGS

4) DIAGNOSTICS

5) REMOTE LOGON

(L)ogout

REMOTE LOGON PASWORD>

Page 41: Campus-RS G.703 Interface Card

Logging On and Off

Campus-RS G.703 Interface Card User Manual 4-7

Although the ASCII terminal is physically connected to the local unit, the header shows it as if it were connected to the remote unit. The prompt changes to REMOTE LOGON PASSWORD.

The screens and procedures on the Remote Main Menu are identical to those on the Local Main Menu, except that the REMOTE LOGON option is unavailable.

4

Logging Off from a Campus Unit

To log off from a local Campus unit:

1 At the Main Menu, type for Logout, then press to log off the unit menus.

2 If the Main Menu is not the current menu, press for Return to the higher-level menu, then press . Repeat this step until the display returns to the Main Menu.

This procedure works from a remote Campus unit. If you are logged into a remote Campus unit and you want to log off completely, type for Logout, then press to log off the remote unit. Then repeat this procedure to log off the local unit.4

� �����

�����

�����

Page 42: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-8 Campus-RS G.703 Interface Card User Manual

USING THE TERMINAL MENUS

Each menu identifies all the keys that you can use on that menu. The following keys operate identically on all menus:

There are two types of configuration options. One type lets you select the desired value from a list of predefined values. The other type prompts you to type in the required information.

To set an option from a list of predefined values:

1 Type the number of the option, then press . The option setting changes to the next value in the list and the screen redraws.

2 Repeat Step 1 until the option is set to the desired value.

To set an option that requires you to enter information:

1 Type the number of the option, then press . The screen prompts you for information.

2 Type the information in the format requested, then press .

See “ASCII Terminal Menu Reference” on page 5 for a map of the ASCII terminal menu structure.4

Key Function

through Type the number of a menu item to select that item.

Exit the current menu and return to the next higher-level menu.

Return to the Main Menu. This option is only available on screens that are located more than one level below the Main Menu.

After typing any of the keys listed above, you must then press to enter the command.

� �

�����

�����

�����

�����

Page 43: Campus-RS G.703 Interface Card

Restoring the System to Default Values

Campus-RS G.703 Interface Card User Manual 4-9

RESTORING THE SYSTEM TO DEFAULT VALUES

You can restore all configuration options to their factory default values. This is an easy way to remove undesired configurations that you may have set.

1 At the Main Menu, type , then press to display the System Settings Menu.

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:07:09

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

SYSTEM SETTINGS MENU

1) SYSTEM PARAMETERS

2) HDSL PARAMETERS

(R)eturn

ENTER CHOICE>

Page 44: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-10 Campus-RS G.703 Interface Card User Manual

2 Type , then press to display the System Parameters menu.

3 Type , then press to restore the configuration options to their factory default values, as listed in “Default Settings” on page 1. The display returns to the System Parameters menu.

4

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:07:25

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

SYSTEM PARAMETERS

1) CHANGE SYSTEM TIME:

2) CHANGE SYSTEM DATE:

3) CHANGE UNIT ID:

4) CHANGE CIRCUIT ID:

5) CHANGE PASSWORD:

6) HDSL ES ALARM THRESHOLD: DISABLED (17, 170, DISABLED)

7) HDSL MARGIN ALARM THRESHOLD: DISABLED

8) ALARM ON LOCAL I/F LOS DISABLED (ENABLED / DISABLED)

9) ALARM ON REMOTE I/F LOS DISABLED (ENABLED / DISABLED)

10) RESET TO FACTORY DEFAULT:

(R)eturn (M)ain Menu

ENTER CHOICE>

� �����

Page 45: Campus-RS G.703 Interface Card

Configuring as a Master or Slave Unit

Campus-RS G.703 Interface Card User Manual 4-11

CONFIGURING AS A MASTER OR SLAVE UNIT

The Transceiver Mode option determines the hierarchy of the two Campus-HRS units when they are attempting to establish an HDSL link.

The Transceiver Mode option has three settings: Auto, Master, and Slave.

• If a unit is set to Auto (default), it automatically switches between Master and Slave until the HDSL link is established. The setting of the other Campus unit is irrelevant.

• If a unit is set to Master, it initiates the HDSL link. The other Campus unit must be set to Slave or Auto.

• If a unit is set to Slave, it waits for the other Campus unit to initiate the HDSL link. The other unit must be set to Master or Auto.

Unless you have an important reason for doing otherwise, leave the Transceiver Mode option set to Auto.

Page 46: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-12 Campus-RS G.703 Interface Card User Manual

To reconfigure the unit to Master or Slave:

1 Press , then press until you return to the Main Menu.

2 At the Main Menu, type , then press to display the System Settings menu.

� �����

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:10:09

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

SYSTEM SETTINGS MENU

1) SYSTEM PARAMETERS

2) HDSL PARAMETERS

(R)eturn

ENTER CHOICE>

Page 47: Campus-RS G.703 Interface Card

Configuring as a Master or Slave Unit

Campus-RS G.703 Interface Card User Manual 4-13

3 Type , then press . The Standard Mode HDSL Parameters menu displays.

4 Type , then press . The Transceiver Mode option changes to the next available setting.

5 Repeat Step 4 until the Standard Mode HDSL Parameters menu displays the desired Transceiver Mode settings.

4

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:10:14

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

STANDARD MODE HDSL PARAMETERS

1) HDSL OPERATING MODE: Standard

2) TRANSCEIVER MODE: Auto (Auto, Master, Slave)

3) HDSL RATE: E1

Changes Will Not be Effective Until This Menu Is Exited!

(R)eturn (M)ain Menu

ENTER CHOICE>

� �����

Page 48: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-14 Campus-RS G.703 Interface Card User Manual

VIEWING AND CONFIGURING ALARMS

You can configure the following alarm options: HDSL Errored Seconds (ES) Alarm Threshold, HDSL Margin Alarm Threshold, Alarm on Local Interface Loss of Signal (I/F LOS), and Alarm on Remote I/F LOS.

To configure the alarm options:

1 At the Main Menu, type , then press to display the System Settings menu.

4

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:10:19

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

SYSTEM SETTINGS MENU

1) SYSTEM PARAMETERS

2) HDSL PARAMETERS

(R)eturn

ENTER CHOICE>

Page 49: Campus-RS G.703 Interface Card

Viewing and Configuring Alarms

Campus-RS G.703 Interface Card User Manual 4-15

2 Type , then press to display the System Parameters menu.

4HDSL Errored Seconds (ES) Alarm Threshold

You can configure the HDSL Errored Seconds (ES) Alarm Threshold either to Disabled or to the number of errored seconds that must occur within a 15-minute period to trigger an alarm (17 or 170). To configure the HDSL ES Alarm Threshold:

1 At the System Parameters menu, type , then press . The System Parameters menu displays the next available HDSL ES Alarm Threshold setting, in errored seconds.

2 Repeat Step 1 until the desired setting displays.4

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:07:25

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

SYSTEM PARAMETERS

1) CHANGE SYSTEM TIME:

2) CHANGE SYSTEM DATE:

3) CHANGE UNIT ID:

4) CHANGE CIRCUIT ID:

5) CHANGE PASSWORD:

6) HDSL ES ALARM THRESHOLD: DISABLED (17, 170, DISABLED)

7) HDSL MARGIN ALARM THRESHOLD: DISABLED

8) ALARM ON LOCAL I/F LOS DISABLED (ENABLED / DISABLED)

9) ALARM ON REMOTE I/F LOS DISABLED (ENABLED / DISABLED)

10) RESET TO FACTORY DEFAULT:

(R)eturn (M)ain Menu

ENTER CHOICE>

� �����

Page 50: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-16 Campus-RS G.703 Interface Card User Manual

HDSL Margin Alarm Threshold

HDSL Margin Alarm Threshold determines the Signal-to-Noise Ratio (SNR) margin, in dB, that triggers an alarm. You can configure the HDSL Margin Alarm Threshold anywhere between 1 dB and 25 dB, in 1 dB increments, or you can disable this alarm.

To configure the HDSL Margin Alarm Threshold:

1 At the System Parameters menu, type , then press . A message displays, prompting you to enter the margin in dB.

2 Type the desired margin threshold value, to a maximum of 25dB (or to disable), then press . The System Parameters menu displays the HDSL Margin Threshold setting that you typed.

4

Alarm on Local Interface Loss of Signal

Alarm on Local Interface Loss of Signal (Local I/F LOS) lets you enable or disable the local Loss of Signal alarm.

1 At the System Parameters menu, type then press . The System Parameters menu displays the new Alarm on Local I/F LOS setting.

2 Repeat the previous step until the desired setting displays.4

Alarm on Remote Interface Loss of Signal

Alarm on Remote I/F LOS lets you enable or disable the remote Loss of Signal alarm.

1 At the System Parameters menu, type , then press . The System Parameters menu displays the new Alarm on Remote I/F LOS setting.

2 Repeat the previous step until the desired setting displays.4

� �����

�����

� �����

� �����

Page 51: Campus-RS G.703 Interface Card

Entering System Information

Campus-RS G.703 Interface Card User Manual 4-17

ENTERING SYSTEM INFORMATION

System information is not required for system operation but it can assist in maintenance and troubleshooting tasks.

This section describes how to enter the following information about the system:

• setting the system time and date

• setting a password

• labeling the unit and circuit with unique identifiers

To enter system information:

1 At the Main Menu, type , then press to display the System Settings menu.

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:10:39

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

SYSTEM SETTINGS MENU

1) SYSTEM PARAMETERS

2) HDSL PARAMETERS

(R)eturn

ENTER CHOICE>

Page 52: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-18 Campus-RS G.703 Interface Card User Manual

2 Type , then press to display the System Parameters menu.

3 Continue with the following sections to set system parameters.

4

Setting the Time and Date

The Campus-HRS Line Unit or Desktop Unit uses the time and date to record system events, such as alarms.

To set the time and date:

1 At the System Parameters menu, type , then press . The system prompts you to enter the time.

2 Type the time, in 24-hour format:

HH:MM:SS

For example, type 13:02:03 to set the time to three seconds after 1:02 P.M.

This manual discusses the menu items in the order most convenient for setup and configuration.

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:07:25

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

SYSTEM PARAMETERS

1) CHANGE SYSTEM TIME:

2) CHANGE SYSTEM DATE:

3) CHANGE UNIT ID:

4) CHANGE CIRCUIT ID:

5) CHANGE PASSWORD:

6) HDSL ES ALARM THRESHOLD: DISABLED (17, 170, DISABLED)

7) HDSL MARGIN ALARM THRESHOLD: DISABLED

8) ALARM ON LOCAL I/F LOS DISABLED (ENABLED / DISABLED)

9) ALARM ON REMOTE I/F LOS DISABLED (ENABLED / DISABLED)

10) RESET TO FACTORY DEFAULT:

(R)eturn (M)ain Menu

ENTER CHOICE>

� �����

Page 53: Campus-RS G.703 Interface Card

Entering System Information

Campus-RS G.703 Interface Card User Manual 4-19

3 Press . The system displays the System Parameters menu with the time that you typed.

4 Type , then press . The system prompts you to enter the date.

5 Type the date in the following format:

MM/DD/YYYY

where MM is the month, DD is the date, and YYYY is the four-digit year.

6 Press . The system displays the System Parameters menu with the date that you typed.

4Changing a Password

A password prevents unauthorized access to Campus configuration options. Once a password has been set, it must be entered to log on to the system.

Your password can be any combination of up to ten letters or numbers, but the first character must be a letter. Passwords are case-sensitive.

To change or set a password:

1 At the System Parameters menu, type , then press . The system prompts you to enter the existing password.

2 If a password has already been set, type the password, then press . If there is no password, just press . The system prompts you to enter the new password.

If you did not enter the correct password, the system prompts you to enter it again. If this happens, repeat the previous step.

3 Type the new password, up to ten characters, then press . The system prompts you to confirm the password.

If no password has been set, press to log onto the Campus menus.

�����

� �����

�����

�����

�����

�����

�����

�����

Page 54: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-20 Campus-RS G.703 Interface Card User Manual

4 Type the new password again, then press . The System Parameters menu displays.

If you did not enter the correct password, the system prompts you to enter the new password again. If this happens, return to Step 3.

Changing the Unit ID and the Circuit ID

The Campus system supports two identifiers:

• The Unit ID identifies the individual Campus-HRS Line Unit or Desktop Unit.

• The Circuit ID identifies the individual HDSL circuit. It is the same for both the local and remote units.

To set or change the Unit ID and Circuit ID:

1 At the System Parameters menu, type , then press . The system prompts you to enter the Unit ID.

2 Type a unique identifier for the unit. There are no limits on which characters you use, but the length of the unit identifier must not exceed 32 characters.

3 Press . The system displays the System Parameters menu with the unit ID that you typed.

4 Type , then press . The system prompts you to enter the circuit ID.

5 Type a unique identifier for the circuit. There are no limits on which characters you use but the length of the circuit identifier must not exceed 64 characters.

6 Press . The system displays the System Parameters menu with the circuit ID that you typed.

4

If you forget your password and cannot log onto the Campus-RS G.703 Interface Card, use the LCD to restore the configuration settings to their default values. This removes the password. For details see “Restoring the System to Default Values” on page 3.

�����

� �����

�����

� �����

�����

Page 55: Campus-RS G.703 Interface Card

Configuring Loopbacks

Campus-RS G.703 Interface Card User Manual 4-21

CONFIGURING LOOPBACKS

Loopbacks provide a way to test the data communication path between the Campus unit, the remote unit, and the remote host equipment. The Campus-RS G.703 Interface Card supports loopbacks on each of its data ports on the local or remote unit.

The Campus-RS G.703 Interface Card supports the following four types of loopback test:

• Local to Local Interface

• Remote to Local Interface

• Local to Remote Interface

• Remote to Remote Interface

See Chapter 6 for a description of these loopbacks.

Once a loopback condition has been initiated, it remains in effect until cleared. You may set a loopback timeout to clear the loopback automatically after a set period of time has elapsed. The default timeout is 20 minutes.

1 At the Main Menu, type , then press to display the Diagnostics menu.

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 09:01:06

Local Unit ID: Campus-HES Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

DIAGNOSTICS MENU

1) LOOPBACK SETTINGS

2) DOWNLOAD MODE

(R)eturn

ENTER CHOICE>

Page 56: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-22 Campus-RS G.703 Interface Card User Manual

2 To display the Loopback Settings menu, type , then press .

4The following sections describe how to perform individual loopback tasks.

Initiating a Loopback

To initiate a loopback:

1 At the Loopback Settings menu, type the number of the desired loopback that you wish to initiate. The options are:

1) Local Data Port Toward Local Data Port

2) Remote Data Port Toward Local Data Port

3) Local Data Port Toward Remote Data Port

4) Remote Data Port Toward Remote Data Port

2 Press . The Loopback Settings menu changes to display the loopback that you selected.

4

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 09:01:12

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

LOOPBACK SETTINGS

1) Local Data Port Toward Local Data Port

2) Remote Data Port Toward Local Data Port

3) Local Data Port Toward Remote Data Port

4) Remote Data Port Toward Remote Data Port

5) Terminate Loopbacks

6) Loopback Timeout (min): (20, 60, 120, None)

WARNING: Any loopback will remove data link from service.

(R)eturn (M)ain Menu

ENTER CHOICE>

�����

Page 57: Campus-RS G.703 Interface Card

Configuring Loopbacks

Campus-RS G.703 Interface Card User Manual 4-23

Terminating All Loopbacks

To manually terminate all loopbacks, at the Loopback Settings menu type , then press . The system disables any loopbacks that are set and displays the Loopback Settings menu.

Setting a Loopback Timeout

The loopback timeout determines the amount of minutes before a loopback clears automatically. You can select from among the following settings: 20, 60, 120, or None. The default is 20 minutes. Selecting None disables the loopback timeout.

To set a Loopback Timeout through an ASCII terminal:

1 At the Loopback Settings menu, type , then press . The Loopback Settings menu displays the next available Loopback Timeout setting.

2 Repeat the previous step until the desired setting displays.

If you set the loopback timeout to None, loopbacks run until you clear them manually or turn the unit off.

�����

� �����

Page 58: Campus-RS G.703 Interface Card

Chapter 4: Configuring through an ASCII Terminal (Console)

4-24 Campus-RS G.703 Interface Card User Manual

Page 59: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual 5-1

5USING AN ASCII TERMINAL

TO VIEW INFORMATIONAND STATUS

This chapter describes how to use an ASCII terminal (console) to view performance and product information. To use an ASCII terminal to configure system options, see Chapter 4.

To view the information described in this chapter, you must first connect an ASCII terminal to the Campus-HRS Desktop Unit or Campus-HRS Line Unit in which the Campus-RS G.703 Interface Card is installed. Follow the instructions in “Connecting to an ASCII Terminal” on page 4-1 to connect to a terminal.

You may also use the LCD menus to view the information described in this chapter. See Chapter 3 for instructions on using the LCD panel.

You access the options in this chapter from the Main Menu, as shown below. See “Logging Onto a Local Campus Unit” on page 4-4 to access the Main Menu.5

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 08:02:33

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

MAIN MENU

1) SYSTEM STATUS

2) DATA PORT STATUS

3) SYSTEM SETTINGS

4) DIAGNOSTICS

5) REMOTE LOGON

(L)ogout

ENTER CHOICE>

Page 60: Campus-RS G.703 Interface Card

Chapter 5: Using an ASCII Terminal to View Information and Status

5-2 Campus-RS G.703 Interface Card User Manual

MONITORING HDSL PERFORMANCE

The Current System Status menu provides a variety of information on the performance of the Campus system.

1 At the Main Menu, type , then press . The System Status Menu displays.

2 Type , then press to display the Current System Status screen.

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 13:02:42

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

SYSTEM STATUS MENU

1) CURRENT SYSTEM STATUS

2) 24 HOUR HDSL PERFORMANCE HISTORY

3) 7 DAY HDSL PERFORMANCE HISTORY

4) LOCAL ALARM HISTORY

5) PRODUCT INFORMATION

(R)eturn

ENTER CHOICE>

� �����

Page 61: Campus-RS G.703 Interface Card

Monitoring HDSL Performance

Campus-RS G.703 Interface Card User Manual 5-3

The Current System Status screen provides the following information:

● Local Alarms indicates the current local alarm status.

● Remote Alarms indicates the current remote alarm status.

● Loopback indicates the current loopback setting.

● Margin (dB) indicates the minimum (mn), current (cr), and maximum (mx) HDSL Signal-to-Noise ratio (SNR) margin value, measured in dB, relative to the signal-to-noise ratio required for a Bit Error Rate (BER) of 10-7.

● Pulse Attn (dB) Indicates the attenuation of the of the transmitted signal, in dB, from the distant end.

● 24 Hour ES indicates the number of Errored Seconds over the last 24 hours.

● 24 Hour UAS indicates the number of Unavailable Seconds over the last 24 hours.

● Last Cleared indicates the date and time when the error counter was last cleared.

5

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 13:02:48

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

CURRENT SYSTEM STATUS

Local Alarms:

Remote Alarms:

Loopback: None

HDSL-A HDSL-B

LOCAL REMOTE LOCAL REMOTE

-------- -------- -------- --------

mn/cr/mx mn/cr/mx mn/cr/mx mn/cr/mx

Margin (dB): 20/24/25 21/22/24 19/22/24 21/22/23

Pulse Attn (dB): 05 05 05 05

24 Hour ES: 00003 00005 00003 00002

24 Hour UAS: 00015 00000 00020 00000

Last Cleared: Mar 19, 1999-00:00

(U)pdate (C)lear

(R)eturn (M)ain Menu

ENTER CHOICE>

Page 62: Campus-RS G.703 Interface Card

Chapter 5: Using an ASCII Terminal to View Information and Status

5-4 Campus-RS G.703 Interface Card User Manual

The information on the Current System Status menu does not update automatically. To update this information, type , then press .

To clear the 24 Hour ES and 24 Hour UAS counters and reset the margin minimum and maximum values to the current value, type , then press

.

24-Hour HDSL Performance History

To display HDSL performance history data for the last 24 hours, in 15-minute increments:

1 At the Main Menu, type , then press to display the System Status menu.

2 Type , then press to display the 24 Hour HDSL Performance History screen.

5

� �����

�����

� �����

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 13:33:08

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

24 HOUR HDSL PERFORMANCE HISTORY

HDSL-A HDSL-B

LOCAL REMOTE LOCAL REMOTE

ES/UAS ES/UAS ES/UAS ES/UAS

-------- -------- -------- --------

11:45 000/000 000/000 000/000 000/000

12:00 000/000 000/000 000/000 000/000

12:15 000/000 000/000 000/000 000/000

12:30 000/000 000/000 000/000 000/000

12:45 000/000 000/000 000/000 000/000

13:00 000/000 000/000 000/000 000/000

13:15 000/000 000/000 000/000 000/000

13:30 000/000 000/000 000/000 000/000

Current 003/000 000/000 000/000 000/000

(P)revious (N)ext (U)pdate

(R)eturn (M)ain Menu

ENTER CHOICE>

Page 63: Campus-RS G.703 Interface Card

Monitoring HDSL Performance

Campus-RS G.703 Interface Card User Manual 5-5

To update information on the current screen, type , then press . Each screen displays up to two hours of history data. You can view the entire 24-hour history (twelve screens in all) as follows:

● To view the previous page, type , then press .

● To view the next page of the report, type , then press .

5

Seven-Day HDSL Performance History

To display HDSL performance history data for the last seven days plus the current day:

1 At the Main Menu, type , then press to display the System Status menu.

2 Type , then press to display the 7 Day HDSL Performance History screen.

Performance history information is lost when power is removed from the Campus unit.

� �����

�����

� �����

� �����

�����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 13:33:18

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

7 DAY HDSL PERFORMANCE HISTORY

HDSL-A HDSL-B

LOCAL REMOTE LOCAL REMOTE

ES/UAS ES/UAS ES/UAS ES/UAS

-------- -------- -------- --------

Jan 05 00000/00000 00000/00000 00000/00000 00000/00000

Jan 06 00000/00000 00000/00000 00000/00000 00000/00000

Jan 07 00000/00000 00000/00000 00000/00000 00000/00000

Jan 08 00000/00000 00000/00000 00000/00000 00000/00000

Jan 09 00000/00000 00000/00000 00000/00000 00000/00000

Jan 10 00000/00000 00000/00000 00000/00000 00000/00000

Jan 11 00000/00000 00000/00000 00000/00000 00000/00000

Jan 12* 00000/00000 00000/00000 00000/00000 00000/00000

*Since Midnight

(U)pdate

(R)eturn (M)ain Menu

ENTER CHOICE>

Page 64: Campus-RS G.703 Interface Card

Chapter 5: Using an ASCII Terminal to View Information and Status

5-6 Campus-RS G.703 Interface Card User Manual

To update the information on this screen, type , then press .

5Viewing Local Alarm History

To view local alarm history information:

1 At the Main Menu, type , then press to display the System Status menu.

2 Type , then press to display the Local Alarm History.

This screen shows the alarm history of the local unit. The screen includes information on the following alarms:

● Errored seconds (ES)

● Margin

● Loss of Signal (LOS) for the G.703 port

Performance history information is lost when power is removed from the Campus unit.

� �����

� �����

� �����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 13:33:26

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

LOCAL ALARM HISTORY

Type Current First Last Count

HDSL Link, OFF Mar 20, 1999-00:00 Mar 20, 1999-00:00 1

ES, HDSL-A OFF 0

ES, HDSL-B OFF 0

Margin, HDSL-A OFF 0

Margin, HDSL-B OFF 0

LOS, Port OFF 0

Last Cleared: NONE

(S)witch to Remote Alarm History

(U)pdate (C)lear

(R)eturn (M)ain Menu

ENTER CHOICE>

Page 65: Campus-RS G.703 Interface Card

Viewing Product Information

Campus-RS G.703 Interface Card User Manual 5-7

To switch to viewing remote alarm history, type , then press .

To update the information, type , then press .

To clear the information, type , then press .

5

VIEWING PRODUCT INFORMATION

To display product information:

1 At the Main Menu, type , then press to display the System Status menu.

2 Type , then press to display the product information screen. It displays:

● Software Version

● PROM checksum

● Hardware Version

● Hardware configuration information, such as the chassis into which the card is installed and the type of power used

Alarm history information is lost when power is removed from the Campus unit.

� �����

� �����

� �����

� �����

�����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 13:33:36

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F: G.703

Circuit ID: Remote Network Circuit #14

PRODUCT INFORMATION

Software Version: x.xx

PROM checksum: xxxx

Hardware Version: xxxx

Desktop

AC

RTC not installed

(R)eturn (M)ain Menu

ENTER CHOICE>

Page 66: Campus-RS G.703 Interface Card

Chapter 5: Using an ASCII Terminal to View Information and Status

5-8 Campus-RS G.703 Interface Card User Manual

5VIEWING DATA PORT STATUS

To open the Data Port Status screen, at the Main Menu, type , then press .

The Data Port Status screen provides the following information:

● BPV Seconds: the number of seconds (from 0 to 99,999) in which at least one bi-polar violation has occurred on the G.703 interface since startup or since the counter was last cleared.

● G.703 UAS Count: the number of seconds (from 0 to 99,999) that either a bi-polar violation or a Loss of Signal (LOS) indication has occurred on the G.703 interface since startup or since the counter was last cleared. This count is unique from the HDSL UAS count.

AIS Signal: the activity status (None or Active) of the AIS signal.

The information on the Data Port Status screen does not update automatically. To update this information with the most recent statistics, type , then press

.

To clear the counters and reset the values to the current value, type , then press . If the information has not been cleared since startup, the Last Cleared field indicates None.

�����

Mar 20, 1999 PAIRGAIN TECHNOLOGIES, CAMPUS HRS, Version x.xx 13:33:46

Local Unit ID: Campus-HRS Unit #17 Local I/F: G.703

Remote Unit ID: Campus-HRS Unit #31 Remote I/F:

Circuit ID: Remote Network Circuit #14

DATA PORT STATUS

BPV Seconds: 0

G.703 UAS Count: 0

AIS Signal: OFF

Last Cleared: None

(U)pdate (C)lear

(R)eturn

ENTER CHOICE>

�����

�����

Page 67: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual 6-1

6TESTING THE SYSTEM

The Campus-RS G.703 Interface Card supports a complete set of loopback functions that allow you to test the data communication path between the host equipment, the Campus unit, and the remote unit. You can use either the LCD and menu buttons or an ASCII terminal to initiate loopback tests.

To use an LCD to initiate a loopback, see “Configuring Loopbacks” on page 11. To use an ASCII terminal to initiate a loopback, see “Configuring Loopbacks” on page 21.

Initiating a loopback test interrupts normal system operation, which causes the Test LED on the Campus HRS Desktop Unit or Line Unit front panel to turn on. When the loopback is cancelled, the system automatically returns to normal operation.

Page 68: Campus-RS G.703 Interface Card

Chapter 6: Testing the System

6-2 Campus-RS G.703 Interface Card User Manual

TYPES OF LOOPBACKS

The Campus-RS G.703 Interface Card supports the following loopback test:

● Local to Local Interface

● Remote to Local Interface

● Local to Remote Interface

● Remote to Remote Interface

Each loopback tests a different portion of the communication path, which lets you isolate communication problems. For each test, the terms “local” and “remote” are relative to the Campus unit from which you initiate the loopback test.

Local to Local Loopback

The Local to Local loopback verifies that the local host equipment, local G.703 cable, and local interface card are installed and configured properly. The remote host equipment is not involved in this loopback.

Page 69: Campus-RS G.703 Interface Card

Types of Loopbacks

Campus-RS G.703 Interface Card User Manual 6-3

Remote to Local Loopback

The Remote to Local loopback tests the remote port, the entire data path inside the local and remote Campus units, the HDSL line, and the HDSL transceivers of both units. Use this loopback to verify that the HDSL line is operational and that the HDSL transceiver of the remote unit is operational. The remote host equipment is not involved in this loopback.

Local to Remote Loopback

The Local to Remote loopback tests the local port, the entire data path inside the local and remote Campus units, the HDSL line, and the HDSL transceivers on both units. The local host equipment is not involved in this loopback.

Remote to Remote Loopback

The Remote to Remote loopback verifies that the remote host equipment, remote data interface cable, and remote interface card are installed and configured properly. The local host equipment is not involved in this loopback.

The remote interface card determines which remote loopbacks available. Depending upon the remote interface card type, some remote loopback options may not be available.

Page 70: Campus-RS G.703 Interface Card

Chapter 6: Testing the System

6-4 Campus-RS G.703 Interface Card User Manual

TERMINATING LOOPBACKS

You can terminate (clear) all loopback tests in the following two ways:

● cancel the loopback manually from either the LCD or an ASCII terminal

● set the Loopback Timeout option to cancel the loopback automatically after a set period of time

Clearing Loopbacks Manually

You can clear a loopback from either the LCD or an ASCII terminal. To use the LCD, see “Terminating All Loopbacks” on page 12. To use an ASCII terminal, see “Terminating All Loopbacks” on page 23.

Loopback Timeout

When a loopback is in use, there is a possibility that it will be forgotten. If a loopback remains in use, the communication link remains down. The Loopback Timeout configuration option provides a way to prevent this from happening by setting how long a loopback remains active.

You can set the Loopback Timeout to 20, 60, or 120 minutes. Then, when a loopback is enabled, it terminates automatically and the HDSL link is reestablished after the Loopback Timeout duration has elapsed.

To set the Loopback Timeout through the LCD, see “Setting a Loopback Timeout” on page 12. To set the Loopback Timeout through an ASCII terminal, refer to “Setting a Loopback Timeout” on page 23.

If you set the loopback timeout to None, loopbacks run until you clear them manually or turn the unit off.

Page 71: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual A-1

ATECHNICAL REFERENCE

This chapter includes technical reference information about the Campus-RS G.703 Interface Card.

TECHNICAL SPECIFICATIONS

DEFAULT SETTINGS

The following table lists default settings for the Campus-RS G.703 Interface Card configuration options:

Interface Types 70-ohm unbalanced (coaxial)120-ohm balanced (twisted pair)

Data Rate 2048 kbps

Line Code HDB3

Clock Signal Derived from input data signal

Item Description Default Value

HDSL

HDSL Mode Standard

HDSL Rate E1

XCVR Mode Auto

Loopback Timeout 20 minutes

Page 72: Campus-RS G.703 Interface Card

Appendix A: Technical Reference

A-2 Campus-RS G.703 Interface Card User Manual

PINOUTS

This section shows G.703 port pinouts for the 120 ohm Campus-RS G.703 Interface Card. Pins that are not defined in this manual are not used.

Pin Signal Direction

1 Receive Ring To Campus unit

9 Receive Tip To Campus unit

2 Receive Shield

3 Transmit Ring From Campus unit

11 Transmit Tip From Campus unit

4 Transmit Shield

6 Alarm - normally closed (NC)

7 Alarm - common (C)

8 Alarm - normally open (NO)

Page 73: Campus-RS G.703 Interface Card

LCD Menu Reference

Campus-RS G.703 Interface Card User Manual A-3

LCD MENU REFERENCE

The following illustration diagrams the LCD menu structure.

Page 74: Campus-RS G.703 Interface Card

Appendix A: Technical Reference

A-4 Campus-RS G.703 Interface Card User Manual

Page 75: Campus-RS G.703 Interface Card

ASCII Terminal Menu Reference

Campus-RS G.703 Interface Card User Manual A-5

ASCII TERMINAL MENU REFERENCE

The following illustration diagrams the ASCII terminal menu structure.

SYSTEM STATUS

24-HOUR HISTORY

7-DAY HISTORY

LOCAL ALARM HISTORY

PRODUCT INFORMATION

CURRENT SYSTEM STATUS

DATA PORTSTATUS

REMOTE ALARM HISTORY

CHANGE SYSTEM TIME

CHANGE CIRCUIT ID

CHANGE UNIT ID

LOCAL DATA PORT LOS ALARM

CHANGE SYSTEM DATE

HDSL ES ALARM THRESHOLD

HDSL MARGIN ALARM THRESHOLD

CHANGE PASSWORD

REMOTE DATA PORT LOS ALARM

RESET TO FACTORY DEFAULT

SYSTEM PARAMETERS

LOOPBACK SETTINGS

DOWNLOAD MODE

SYSTEM SETTINGS

DIAGNOSTICS

HDSL OPERATING MODE

LOCAL DATA PORT TOWARD LOCAL DATA PORT

LOCAL DATA PORT TOWARD REMOTE DATA PORT

REMOTE DATA PORT TOWARD LOCAL DATA PORT

REMOTE DATA PORT TOWARD REMOTE DATA PORT

TERMINATE LOOPBACKS

LOOPBACK TIMEOUT (min)

TRANSCEIVER MODE

HDSL PARAMETERS

Page 76: Campus-RS G.703 Interface Card

Appendix A: Technical Reference

A-6 Campus-RS G.703 Interface Card User Manual

Page 77: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual B-1

BABBREVIATIONS

2B1Q 2 Binary, 1 QuarternaryAIS Alarm Indication Signal (a pattern of all ones)BER Bit Error RateBPV Bi-polar violationCMU Campus Management UnitES Errored SecondsHDSL High-bit-rate Digital Subscriber LineLOC LocalLOS Loss of SignalMSB Most Significant BitsNC Normally ClosedNO Normally OpenNVRAM Non-volatile Random Access MemoryPLL Phase Lock LoopREM RemoteRS HDSL Rate-SelectableSNR Signal-to-Noise RatioUAS Unavailable SecondsUL Underwriters Laboratory

Page 78: Campus-RS G.703 Interface Card

Appendix B: Abbreviations

B-2 Campus-RS G.703 Interface Card User Manual

Page 79: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual C-1

CTHE DOCUMENTATION SET

This table describes all the manuals and guides in the Campus-RS documentation set.

Document Description

Campus-Star User Manual

Contains instructions for setting up and using a Campus-Star. The manual includes instructions for installing interface cards into the Campus-Star chassis.

Campus-RS Line Unit User Manual

Describes the features of the Campus-RS Line Unit and provides installation instructions.

Campus-RS Desktop Unit User Manual

Describes the features of the Campus-RS Desktop Unit and provides instructions for installing interface cards and connecting the unit to an HDSL line.

Campus-RS interface card user manuals

Describes the features of the individual Campus interface cards, one card per manual, and contains instructions for configuring and monitoring the system through the cards.

Page 80: Campus-RS G.703 Interface Card

Appendix C: The Documentation Set

C-2 Campus-RS G.703 Interface Card User Manual

Page 81: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual D-1

DTECHNICAL ASSISTANCE

ADC Customer Service Group provides expert pre-sales and post-sales support and training for all its products.

Technical support is available 24 hours a day, 7 days a week by contacting the ADC Technical Assistance Center.

Sales Assistance800.366.3891 extension 73000(USA and Canada)952.917.3000Fax: 952.917.3237

• Quotation Proposals

• Ordering and Delivery• General Product Information

Systems Integration800.366.3891, extension 73000 (USA and Canada)952.917.3000

• Complete Solutions (from concept to installation)

• Network Design and Integration Testing

• System Turn-Up and Testing• Network Monitoring (upstream or

downstream)

• Power Monitoring and Remote Surveillance• Service/Maintenance Agreements

• Systems Operation

ADC Technical Assistance Center800.366.3891, extension 73223 or952.917.3223 Fax: 952.917.3244Email: [email protected]

• Technical Information

• System/Network Configuration• Product Specification and Application

• Training (product-specific)

• Installation and Operation Assistance• Troubleshooting and Repair/Field

Assistance

Page 82: Campus-RS G.703 Interface Card

Appendix D: Technical Assistance

D-2 Campus-RS G.703 Interface Card User Manual

Online Technical Support • www.adc.com/technicalsupport

Online Technical Publications • www.adc.com/documentationlibrary/technicalpublications

Product Return Department800.366.3891 extension 73748 or952.917.3748 Fax: 952.917.3237Email: repair&[email protected]

• ADC Return Material Authorization (RMA) number and instructions must be obtained before returning products.

All telephone numbers with an 800 prefix are toll-free in the USA and Canada.

Page 83: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual Index-1

INDEX

AAIS signal

ASCII terminal ............................ 5-8

LCD ........................................... 3-10

alarm

history

ASCII terminal .........5-4 to 5-7

on Local I/F LOS

ASCII terminal ................. 4-16

LCD ....................................3-9

relay ............................................. 2-7

status

ASCII terminal ........5-2 to 5-7

LCD ....................................3-4

thresholds

ASCII terminal ................. 4-14

LCD ....................................2-6

ASCII terminal

alarm status ......................5-2 to 5-7

configuring alarms .......4-14 to 4-16

connecting ........................4-1 to 4-3

Data Port Status ........................... 5-8

entering system information ..............4-17 to 4-20

logging on ................................... 4-4

loopbacks .....................4-21 to 4-23

Master/Slave settings ................ 4-11

menu reference ........................... A-5

password ................................... 4-19

product information .................... 5-7

PROM checksum ........................ 5-7

selecting options ......................... 4-8

setting the time and date ........... 4-18

unit and circuit ID ..................... 4-20

See also configuration

Auto Master/Slave mode

ASCII terminal .......................... 4-11

LCD ..................................3-3 to 3-4

Bbi-polar violation

See BPV

BPV, ASCII terminal ........................... 5-8

CCampus Management Unit

See LCD

Campus-HRS Desktop Unit

compatibility ............................... 2-1

connecting ASCII terminal ......... 4-2

installing interface card ............... 2-4

Campus-HRS Line Unit

compatibility ............................... 2-1

Page 84: Campus-RS G.703 Interface Card

Index-2 Campus-RS G.703 Interface Card User Manual

Campus-Star

installing interface card ............... 4-2

installing Line Unit ..................... 2-3

cancelling loopbacks

ASCII terminal ............................ 6-4

LCD .............................3-12 to 3-12

checksum information

ASCII terminal ............................ 5-7

LCD ...................................2-3, 3-13

circuit ID

ASCII terminal ...................4-20, 5-7

LCD .......................................... 3-13

clearing loopbacks

ASCII terminal ...................4-23, 6-4

LCD .......................................... 3-12

CMU

See LCD

compatibility ........................................ 2-1

configuration

default values ............................. A-1

remote unit .................................. 4-5

See also ASCII terminal

See also LCD

connecting

alarm relay .................................. 2-7

ASCII terminal ..................4-1 to 4-3

G.703 cable .......................2-5 to 2-6

current system status

ASCII terminal ............................ 5-2

LCD ............................................ 3-6

Ddata cable, connecting .............. 2-5 to 2-6

Data Port Status

ASCII terminal ........................... 5-8

LCD .......................................... 3-10

date, setting ........................................ 4-18

default configuration settings ..............A-1

default values

ASCII terminal ........................... 4-9

LCD ............................................ 3-3

Desktop Unit

compatibility ............................... 2-1

connecting ASCII terminal ......... 4-2

installing Interface Card ............. 2-4

diagnostics

ASCII terminal ......................... 4-21

LCD .......................................... 3-11

EEnter button ......................................... 3-2

ES alarm threshold

ASCII terminal .................. 4-14, 5-6

LCD ............................................ 3-6

Escape button ....................................... 3-2

GG.703 cable, connecting ........... 2-5 to 2-6

G.703, 120 ohm port pinouts ...............A-2

HHDSL, connecting cable ...................... 2-5

Page 85: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual Index-3

Iinitiating loopbacks

ASCII terminal .......................... 4-22

LCD ........................................... 3-11

installing

interface card into Campus-Star .. 2-2

interface card into Desktop Unit . 2-4

Line Unit into Campus-Star ........ 2-3

LLCD

Data Port Status ......................... 3-10

loopbacks ......................3-11 to 3-12

Master/Slave settings ........3-3 to 3-4

navigating menus ..............3-1 to 3-2

product information .................. 3-13

restoring default values ............... 3-3

viewing and configuring alarms .. 3-4

See also configuration

LCD menu reference ........................... A-3

Line Unit

compatibility ............................... 2-1

installing ...................................... 2-3

local alarms

ASCII terminal .......................... 4-14

LCD ............................................. 3-9

local to local loopback .........................6-2

local unit ID

ASCII terminal .....................4-5, 5-7

LCD ........................................... 3-13

logging off ........................................... 4-7

logging onto ASCII terminal ............... 4-4

remote unit .................................. 4-5

loopbacks ..................................6-1 to 6-4

ASCII terminal .............4-21 to 2-23

LCD ..............................3-11 to 3-12

loopback timeout ...3-12 to 3-12, 6-4

ASCII terminal ................. 4-23

LCD ................................. 3-12

See also V.35 loopback support

LOS alarm

ASCII terminal ............................ 5-6

LCD ............................................ 3-9

MMain Menu .....................................4-5, 4-

6Margin alarm

ASCII terminal ...................4-14, 5-6

LCD ............................................ 3-6

Master mode

ASCII terminal .......................... 4-11

LCD ..................................3-3 to 3-4

menu buttons ..............................3-1 to 3-2

See LCD

menu reference

ASCII terminal ........................... A-5

LCD ........................................... A-3

Page 86: Campus-RS G.703 Interface Card

Index-4 Campus-RS G.703 Interface Card User Manual

Nnavigating menus

ASCII terminal ............................ 4-8

LCD ..................................3-1 to 3-2

Next button .......................................... 3-2

Ppassword security ............................... 4-19

pinouts, 120 ohm G.703 port .............. A-2

product information

ASCII terminal ............................ 5-7

LCD .......................................... 3-13

PROM checksum

ASCII terminal ............................ 5-7

LCD .......................................... 3-13

provisioning

See ASCII terminal

See LCD

Rreference, technical ............................. A-1

relay, alarm .......................................... 2-7

remote interface card

ASCII terminal .....................4-4, 5-7

LCD .......................................... 3-13

remote to local loopback ...................... 6-3

remote unit

ID

ASCII terminal ............4-5, 5-7

LCD ................................. 3-13

logging on ................................... 4-5

restoring default values

ASCII terminal ........................... 4-9

LCD ............................................ 3-3

SSeven-Day HDSL Performance

history ............................................. 5-5

Slave mode

ASCII terminal ......................... 4-11

LCD ................................. 3-3 to 3-4

software version

ASCII terminal ........................... 5-7

LCD .......................................... 3-13

specifications .......................................A-1

standard mode .................................... 4-13

starting loopbacks, ASCII terminal ... 4-22

status, LCD .......................................... 3-4

system information

ASCII terminal .....4-17 to 4-20, 5-7

LCD .......................................... 3-13

System Parameters menu .2-10, 2-15, 2-18

System Settings menu .......4-9, 4-12, 4-14, 4-17

System Status menu ............................. 5-2

Ttechnical specifications ........................A-1

terminal

See ASCII terminal

terminating loopbacks

ASCII terminal .................. 4-23, 6-4

LCD .......................................... 3-12

Page 87: Campus-RS G.703 Interface Card

Campus-RS G.703 Interface Card User Manual Index-5

testing with loopbacks ...............6-1 to 6-4

ASCII terminal .............4-21 to 4-23

LCD ..............................3-11 to 3-12

time, setting ........................................ 4-18

timeout ........................................3-12, 6-4

ASCII terminal .......................... 4-23

LCD ........................................... 3-12

Transceiver mode

ASCII terminal .......................... 4-11

LCD ..................................3-3 to 3-4

UUAS count

ASCII terminal ............................ 5-8

LCD .......................................... 3-10

unit ID ................................................ 4-20

ASCII terminal ............................ 4-5

LCD .......................................... 3-13

Vviewing

Data Port Status

ASCII terminal ................... 5-8

data port status

LCD ................................. 3-10

XXCVR mode

See Transceiver mode

Page 88: Campus-RS G.703 Interface Card

Index-6 Campus-RS G.703 Interface Card User Manual

Page 89: Campus-RS G.703 Interface Card
Page 90: Campus-RS G.703 Interface Card

ADC DSL Systems, Inc.14402 Franklin AvenueTustin, CA 92780-7013

Technical AssistanceTel: 800.366.3891 x73223Tel: 952.917.3223Fax: 952.917.3244

��������������

DOCUMENT: 500-934-150-02

´,4K¶1R¨

1220431