Caliber's Maxpran ICU Ventilator · 2020. 9. 23. · Caliber's Maxpran ICU Ventilator “Designed...

5
Caliber's Maxpran ICU Ventilator “Designed as an all purpose ventilator catering to all kinds of clinical care situations - for every patient's needs !” ® The Maxpran is a dual type of clinical-friendly Invasive / Non-invasive venlator (supports Seniors, Adults and Kids) designed to be comfortable for doctors to use and for paents to get treated. Modular and portable device which can be seamlessly integrated in to any crical care ecosystem enabling instant availability of high quality, cost effecve venlaon for all paents in any clinical situaons.

Transcript of Caliber's Maxpran ICU Ventilator · 2020. 9. 23. · Caliber's Maxpran ICU Ventilator “Designed...

Page 1: Caliber's Maxpran ICU Ventilator · 2020. 9. 23. · Caliber's Maxpran ICU Ventilator “Designed as an all purpose ventilator catering to all kinds of clinical care situations -

Caliber's Maxpran ICU Ventilator

“Designed as an all purpose ventilator catering to all kinds of clinical care situations - for every patient's needs !”

® The Maxpran is a dual type of clinical-friendly Invasive / Non-invasive

ven�lator (supports Seniors, Adults and Kids) designed to be

comfortable for doctors to use and for pa�ents to get treated. Modular

and portable device which can be seamlessly integrated in to any cri�cal

care ecosystem enabling instant availability of high quality, cost effec�ve

ven�la�on for all pa�ents in any clinical situa�ons.

Page 2: Caliber's Maxpran ICU Ventilator · 2020. 9. 23. · Caliber's Maxpran ICU Ventilator “Designed as an all purpose ventilator catering to all kinds of clinical care situations -

Compatibility

Our Maxpran ven�la�on can cater to the myriad of ven�la�on needs of

any kind of pa�ent, from neonatal care to adult care. It can be operated in

the most dire phase of respiratory situa�on through the weaning off

stage. Robust design ensures the pa�ent under the ven�la�on is treated

with tenderly care.

Maxpran's user friendly UI lets the doctors and technicians operate the

ven�lator intui�vely and navigate various opera�ng modes without

much hassle. Sophis�cated electronics behind this robust system which

automates the flow control system is based on arm based micro

controller and high precision and high accuracy sensors. Maxpran can be

operated and monitored remotely by doctors and technicians.

Accessibility

Cloud storage ensures that medical data of ven�la�on se�ngs and

opera�onal parameters are preserved to safeguard the privacy of pa�ent

and also can facilitate the introduc�on of ar�ficial medical intelligence to

make be�er respiratory therapeu�c recommenda�ons.

Intelligibility

Modular design of Maxpran® allows swi� integra�on in to any medical

facility ensuring the instant availability of supreme quality ven�la�on in

every imaginable environment including ICU, NICUs and emergency

medical care centers thus freeing up doctors and technicians to focus

exclusively on pa�ents rather on procedural bo�lenecks of se�ng up

ven�lators.

Portability

Page 3: Caliber's Maxpran ICU Ventilator · 2020. 9. 23. · Caliber's Maxpran ICU Ventilator “Designed as an all purpose ventilator catering to all kinds of clinical care situations -

Maxpran lets the doctors and respiratory technicians to operate the ven�lator in 16 different modes catering to every need of the pa�ent and also meets the dynamic demands of medical condi�ons at hand.

Maxpran is designed as an all encompassing unitary system offering a wide arrange of therapeu�c op�ons for dynamic clinical needs. Interchangeable modules and plugging in op�ons ensure up�me is maximized while keeping the ven�la�on cost per pa�ent kept to the bare minimum.

Operability

Affordability

PC-CMVPC-ACPC-SIMV PC-APRVPC-PSVPC-HFOPC-MMVPC-BIPAP

VC-CMV VC-AC VC-SIMV VC-MMV

Volume-controlled

SPN-CPAP/PSSPN-CPAP/VSSPN-PPS

PRVC

Spontaneous/assisted HybridPressure-controlled

“Maxpran acts as an aide-de-camp to doctors and technicians at life saving situations”

Page 4: Caliber's Maxpran ICU Ventilator · 2020. 9. 23. · Caliber's Maxpran ICU Ventilator “Designed as an all purpose ventilator catering to all kinds of clinical care situations -

Key monitoring and alarms

Features

Audible and visual alarm facility is provided about 12 cri�cal error condi�ons listed below:

Power disconnected

Pa�ent disconnected

Inspiratory Pressure

High PEEP

High Respiratory Rate

Power Sensor Failure

Read / Write Error

Ven�lator Temperature Error

System Failure

Low Tidal Volume

Yes / No

Yes / No

High / Low

High / Low

High / Low

High / Low

High / Low

High / Low

Yes / No

Yes / No

Ven�lator features Invasive, Non Invasive and CPAP modes.

It is ar�culated-piston type stand alone compressor,

with dry filtered air.

Adaptable to Adult and Pediatric pa�ents.

It has in-built programmable ultrasonic nebulizer.

Designed for Con�nuous working capability of 4 to 5 days.

Cloud database Management of the pa�ent's data

Provision to view the preceding history of the pa�ent

waveforms & alarm history.

Page 5: Caliber's Maxpran ICU Ventilator · 2020. 9. 23. · Caliber's Maxpran ICU Ventilator “Designed as an all purpose ventilator catering to all kinds of clinical care situations -

“Maxpran Saves lives one breadth at a time“

Technical Data

VENTILATOR SETTINGS

Displayed Parameters

Monitored Parameters

Frac�on of Inspired O2 concentra�on (FiO2)

Ven�lator Respira�on rate

Inspira�on �me (Ti)

Tidal volume (VT)

Inspiratory flow rate

Inspiratory pressure(Pinsp)

Inspiratory pressure limit (Pmax)

PEEP

Slope range

Trigger Flow sensi�vity

Pressure assist (Psupp)

Leak volume compensa�on

Screen Size

21 to 100 %

0.5 to 60bpm

0.3 to 5 secs

50ml to 2000ml

0 to 150lpm

1cmH2O to 60cmH2O

1 to 100cmH2O

0 to 30cmH2O

0 to 2 sec

0.2 to 20 L/min

0 to 40cmH2O

On/Off

16 inch

Respiratory phase / Lung Mechanics

Expiratory Tidal Volume (Tve)

Expiratory Minute Volume (MVe)

Inspiratory/Expiratory

0.3 to 2000ml

0 to 2 L/min

Display of scalars

Display of Loops

Parameters related to Pressure

Parameters related to Volume

Expiratory end CO2 concentra�on

Frac�on of Inspired O2 concentra�on (FiO2)

Compliance

Resistance

Leakage minute volume

Rapid Shallow Breathing Index(RSBI)

Flow, Pressure and Volume

PV,FV and PF loops

Pplat, PEEP, PIP, Pmean

MVe, MVi, MV, Mvmand

0 to 100 mmHg

21 to 100 %

0 - 500 mL/cmH2O

0-800 cmH2O / (L/s)

0 to 100 L/min

0 to 1000 breaths/min/L