Cabling Flexi Multiradio 10 Base Station
description
Transcript of Cabling Flexi Multiradio 10 Base Station
-
WCDMA RAN, Rel. RU40,Operating Documentation,Issue 06
Cabling Flexi Multiradio 10Base Station DN09107822Issue 11Approval Date 2014-06-24
-
Theinformationinthisdocumentissubjecttochangewithoutnoticeanddescribesonlytheproductdefined in the introduction of this documentation. This documentation is intended for the use ofNokiaSolutionsandNetworkscustomersonlyforthepurposesoftheagreementunderwhichthedocumentissubmitted,andnopartofitmaybeused,reproduced,modifiedortransmittedinanyformormeanswithoutthepriorwrittenpermissionofNokiaSolutionsandNetworks.Thedocumen-tationhasbeenpreparedtobeusedbyprofessionalandproperlytrainedpersonnel,andthecus-tomerassumesfullresponsibilitywhenusingit.NokiaSolutionsandNetworkswelcomescustomercommentsaspartoftheprocessofcontinuousdevelopmentandimprovementofthedocumenta-tion.
The informationor statementsgiven in thisdocumentationconcerning thesuitability, capacity, orperformanceofthementionedhardwareorsoftwareproductsaregiven"asis"andallliabilityaris-inginconnectionwithsuchhardwareorsoftwareproductsshallbedefinedconclusivelyandfinallyin a separate agreement between Nokia Solutions and Networks and the customer. However,NokiaSolutionsandNetworkshasmadeallreasonableeffortstoensurethattheinstructionscon-tained in thedocumentareadequateand freeofmaterialerrorsandomissions.NokiaSolutionsandNetworkswill, if deemednecessarybyNokiaSolutionsandNetworks, explain issueswhichmaynotbecoveredbythedocument.
NokiaSolutionsandNetworkswillcorrecterrorsinthisdocumentationassoonaspossible.INNOEVENTWILLNokiaSolutionsandNetworksBELIABLEFORERRORS INTHISDOCUMENTA-TIONORFORANYDAMAGES, INCLUDINGBUTNOTLIMITEDTOSPECIAL,DIRECT, INDI-RECT,INCIDENTALORCONSEQUENTIALORANYLOSSES,SUCHASBUTNOTLIMITEDTOLOSSOFPROFIT,REVENUE,BUSINESSINTERRUPTION,BUSINESSOPPORTUNITYORDA-TA,THATMAYARISEFROMTHEUSEOFTHISDOCUMENTORTHEINFORMATIONINIT.
Thisdocumentationandtheproductitdescribesareconsideredprotectedbycopyrightsandotherintellectualpropertyrightsaccordingtotheapplicablelaws.
NSN is a trademark ofNokiaSolutions andNetworks.Nokia is a registered trademark ofNokiaCorporation.Otherproductnamesmentionedinthisdocumentmaybetrademarksoftheirrespec-tiveowners,andtheyarementionedforidentificationpurposesonly.
CopyrightNokiaSolutionsandNetworks2014.Allrightsreserved
f Important Notice on Product Safety Thisproductmaypresentsafetyrisksduetolaser,electricity,heat,andothersourcesof
danger.
Only trained and qualified personnelmay install, operate,maintain or otherwise handlethisproductandonlyafterhavingcarefully read thesafety informationapplicable to thisproduct.
Thesafety information isprovided in theSafety Informationsection in theLegal,SafetyandEnvironmentalInformationpartofthisdocumentordocumentationset.
NokiaSolutionsandNetworksiscontinuallystrivingtoreducetheadverseenvironmentaleffectsofitsproductsandservices.Wewouldliketoencourageyouasourcustomersanduserstojoinusinworking towards a cleaner, safer environment. Please recycle product packaging and follow therecommendationsforpoweruseandproperdisposalofourproductsandtheircomponents.
IfyoushouldhavequestionsregardingourEnvironmentalPolicyoranyoftheenvironmentalser-vicesweoffer,pleasecontactusatNokiaSolutionsandNetworksforanyadditionalinformation.
CablingFlexiMultiradio10BaseStation
2 DN09107822 Issue:11
-
Table of ContentsThisdocumenthas64pages
Summaryofchanges..................................................................... 7
1 ConnectingSystemModule(FSMx)corecabling.......................... 91.1 Connectingexternalpowerfeed.................................................... 91.2 Connectinginternalopticalcables............................................... 161.3 Connectingtransmissioncables.................................................. 211.3.1 Overviewofconnectingtransmissioncabling.............................. 211.3.2 ConnectingRJ45transmissioncable...........................................211.3.3 ConnectingSFPtransmissioncable............................................ 231.4 ConnectingFSMxcoreoptionalcabling.......................................271.4.1 ConnectingSyncOutcable..........................................................271.4.2 ConnectingSyncIncable............................................................ 281.4.3 ConnectingExternalAlarmsandControls(EAC)cable...............291.4.4 ConnectingexternalIPdevices....................................................30 2 ConnectingFlexiMultiradio10BTSPowerDistributionSub-
Module(FPFD)cabling................................................................ 322.1 FPFDv.103cabling.....................................................................322.2 FPFDv.204Eforecabling........................................................... 372.3 FPFDv.204Artesyncabling........................................................41 3 ConnectingFlexiMultiradio10BTSoptionalTransmissionSub-
Module(FTIF)cabling.................................................................. 47 4 ConnectingFlexiMultiradio10BTSCapacityExtensionSub-
Module(FBBA)cabling................................................................ 49 5 ConnectingFlexiMultiradio10BTSCapacityExtensionSub-
Module(FBBC)cabling................................................................ 53 6 ChecklistforcablingFlexiMultiradio10BTS...............................57 7 Appendices.................................................................................. 587.1 ContentsoftheFlexiMultiradio10BTSopticalcabledeliveries. 587.2 ContentsoftheFlexiMultiradio10BTSopticaltransceiver
deliveries...................................................................................... 597.3 ContentsoftheFlexiMultiradio10BTStransmissioncable
deliveries...................................................................................... 597.4 ContentsoftheFlexiMultiradio10BTSsynchronizationcable
deliveries...................................................................................... 607.5 EACcable(FTSI472578A)wiring............................................... 617.6 FlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)
controlpanel.................................................................................62
CablingFlexiMultiradio10BaseStation
Issue:11 DN09107822 3
-
List of FiguresFigure1 RoutingDCpowercablethroughcableentry.......................................9Figure2 Loosenscrewterminals......................................................................10Figure3 StrippingDCpowercable...................................................................10Figure4 InsertingDCpowercabletoIPboot................................................... 11Figure5 RemovingnarrowendofIPboot........................................................ 12Figure6 Removingtape................................................................................... 12Figure7 InsertDCpowercablewires...............................................................13Figure8 Tightenscrewterminals......................................................................14Figure9 FixingIPboot......................................................................................15Figure10 Installcableentries.............................................................................16Figure11 Installingopticaltransceiver............................................................... 18Figure12 Pullingbackcableconnectorseal...................................................... 19Figure13 Connectingopticalcable.................................................................... 19Figure14 Installingopticalcableconnectorseal................................................ 19Figure15 Routingopticalcable.......................................................................... 20Figure16 ConnectingRJ45transmissioncable................................................. 22Figure17 Insertingopticaltransceiver................................................................24Figure18 Pullingbacktheconnectorseal..........................................................25Figure19 Connectingopticalcable.................................................................... 25Figure20 Connectingopticalcable.................................................................... 26Figure21 Pushingtheconnectorsealinplace...................................................26Figure22 ConnectingSyncOutcable................................................................ 27Figure23 ConnectingSyncIncable...................................................................28Figure24 ConnectingEACcable....................................................................... 29Figure25 ConnectingRJ45cabletoLMPport...................................................31Figure26 PullingFSMxcoreout........................................................................ 33Figure27 LooseningFPFDscrewterminals.......................................................33Figure28 Wrappingtapearoundwires...............................................................34Figure29 InsertingcabletoIPboot....................................................................34Figure30 Removingtape................................................................................... 35Figure31 ConnectingFPFDDCoutputcablewires...........................................35Figure32 TighteningFPFDscrewterminals.......................................................35Figure33 FixingIPboot......................................................................................36Figure34 LooseningFPFDscrewterminals.......................................................38Figure35 Wrappingtapearoundwires...............................................................38Figure36 InsertingcabletoIPboot....................................................................39Figure37 Removingtape................................................................................... 39Figure38 ConnectingFPFDDCoutputcablewires...........................................40
CablingFlexiMultiradio10BaseStation
4 DN09107822 Issue:11
-
Figure39 TighteningFPFDscrewterminals.......................................................40Figure40 FixingIPboot......................................................................................41Figure41 LooseningFPFDscrewterminals.......................................................42Figure42 Wrappingtapearoundwires...............................................................43Figure43 InsertingcabletoIPboot....................................................................43Figure44 Removingtape................................................................................... 44Figure45 ConnectingFPFDDCoutputcablewires...........................................44Figure46 TighteningFPFDscrewterminals.......................................................45Figure47 FixingIPboot......................................................................................46Figure48 ConnectingFTIFcabling.................................................................... 47Figure49 RemovingFBBAIPseals................................................................... 49Figure50 Connectingpowercable..................................................................... 49Figure51 Chainingpowercable......................................................................... 50Figure52 ConnectingQSFPcable..................................................................... 50Figure53 ConnectingsecondQSPFcable........................................................ 51Figure54 BendingtheQSFPcables(1).............................................................52Figure55 BendingtheQSFPcables(2).............................................................52Figure56 RemovingFBBCIPseals................................................................... 53Figure57 Connectingpowercable..................................................................... 53Figure58 ConnectingQSFPcable..................................................................... 54Figure59 ConnectingsecondQSFPcable........................................................ 55Figure60 BendingtheQSFPcables(1).............................................................56Figure61 BendingtheQSFPcables(2).............................................................56Figure62 FPFDcontrolpanel.............................................................................62
CablingFlexiMultiradio10BaseStation
Issue:11 DN09107822 5
-
List of TablesTable1 RATreleasescoveredbythedocument...............................................7Table2 Opticalcabledeliveries.......................................................................58Table3 Opticaltransceiverdeliveries..............................................................59Table4 Transmissioncabledeliveries.............................................................59Table5 Synccabledeliveries..........................................................................60Table6 EACcable(FTSI)wiring..................................................................... 61Table7 FPFDLEDindications........................................................................ 63
CablingFlexiMultiradio10BaseStation
6 DN09107822 Issue:11
-
Summary of changesChangesbetweendocumentissuesarecumulative.Therefore,thelatestdocumentissuecontainsallchangesmadetopreviousissues.
ThisdocumentiscommonforallRadioAccessTechnologies(RAT).YoumayfindhereinformationaboutsolutionsthatarenotavailableorsupportedinaspecificSWreleaseorRAT.TableRATreleasescoveredbythedocumentlistsallSWreleasescoveredbythecontentofthisdocument.ForfeaturessupportedinyourSWrelease,seerespectivefeaturedocumentationchapterinthesystemlibrary.
Table1 RATreleasescoveredbythedocument
Radio Access Technology (RAT)
Product release
GSM RG20,RG30
LTE RL25TD,RL35TD,RL45TD
RL40,RL50,RL60
WCDMA RU40
FlexiMultiradio10BTSisonWN8.03.0levelandisnotvalidforRU50.
Changes between issues 10 (2014-06-04) and 11 (2014-06-24)Connecting Sync In cable
GPScableassembly300mhasbeenaddedtothelist.
FPFD v. 204 Efore cabling
Newchapter.
FPFD v. 204 Artesyn cabling
Newchapter.
Changes between issues 09 (2014-03-25) and 10 (2014-06-04)Flexi Multiradio 10 BTS Power Distribution Sub-Module (FPFD) control panel
OvertempretureremovedfromtheredLEDfaultcaseinTable7:FPFDLEDindications.
FPFD v. 103 cabling
InformationaboutrequiredtoolhasbeenaddedtoStep2.
Connecting SFP transmission cable
Informationaboutusingreel-typeconnectioncleanerhasbeenaddedtoStep5.
Connecting internal optical cables
Step4hasbeenupdated. Notehasbeenupdated.
CablingFlexiMultiradio10BaseStation Summaryofchanges
Issue:11 DN09107822 7
-
Changes between issues 08 (2014-03-07) and 09 (2014-03-25)Connecting Flexi Multiradio 10 BTS Capacity Extension Sub-Module (FBBC)cabling
Newchapter.
Summaryofchanges CablingFlexiMultiradio10BaseStation
8 DN09107822 Issue:11
-
1 Connecting System Module (FSMx) corecabling
1.1 Connecting external power feedBefore you start
g TheFSMxcoreDCinputisonlyusedwhenthereisnoFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)intheconfiguration.
g ExternalsurgeprotectionisalwaysneededinoutdoorinstallationswithFSMFDCinput(withorwithoutFPFD)iftheinputpowerfeederlengthexceeds10m.(InstalledclosetoFSMFDCinputport).
Shieldedpowerfeederisalwaysneededinoutdoorinstallationswhenthepowerfeederlengthexceeds4m.Thepowerfeedercableneedstobegroundedatbothends.
Makesurethatthemoduleisgrounded.
ChooseaDCpowercablebetweenouterdiameterswithasealingof6mmto20mm(0.24-0.79in.).
f WARNING! Risk of short circuit.MakesurethemainsiteswitchisintheOFFpositionbeforeyouconnecttheDCpowercable.
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
Thepowercablemustbeconnectedbeforepowerisappliedtothesystem.
1 Route the DC power cable through the cable entry.
Figure1 RoutingDCpowercablethroughcableentry
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 9
-
2 Loosen the screw terminals of the DC in port on the FSMx front panel.
Figure2 Loosenscrewterminals
DCin
+ -
3 Strip the DC power cable and wrap tape around the exposed wires in order notto break the IP boot.
Figure3 StrippingDCpowercable
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
10 DN09107822 Issue:11
-
4 Insert the taped end of the DC power cable to the IP boot.
Figure4 InsertingDCpowercabletoIPboot
Whenusingathickcable,thenarrowendoftheIPbootcanberemovedusingscissors.Cutinonegosothatyougetacleancutsurface.SeeFigure5:RemovingnarrowendofIPbootfordetails.NotethatyoucaninsertonlyoneDCcablewithadiameterofmax.20mm(0.79in.)totheIPboot.Minimumcablediameteris6mm(0.24in.).
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 11
-
Figure5 RemovingnarrowendofIPboot
Cablediameter1 - mmcutwithscissorsinonego
0.1 17.0
Cablediameter1 -20 mmcutwithscissorsinonego
7.1 .0
Cablediameter - mm(nocuttingneed)
6.0 10.0
5 Remove the tape.
Figure6 Removingtape
6 Insert the DC power cable to the screw terminal and make sure that the polarityof the wires is correct.ConnectthewirestotheV48N-andV48RTN+connectorsaccordingtothemarkingsonthecable.
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
12 DN09107822 Issue:11
-
f WARNING! Risk of power supply failure and, in rare cases, of shortcircuit.Checkthatthepolarityiscorrectaccordingtothemarkingsonthecable.
Figure7 InsertDCpowercablewires
7 Tighten the screw terminals to 5.0 Nm (3.69 ft-lb).MakesurethattheDCpowercableisnotbenttotheleftorrightinordertoavoidtensiontotheDCinputterminals.
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 13
-
Figure8 Tightenscrewterminals
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
14 DN09107822 Issue:11
-
8 Fix the IP boot in place and fix the screw. Tighten to max. 2.0 Nm (1.48 ft-lb).
Figure9 FixingIPboot
1 2
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 15
-
9 Install the cable entries.
Figure10 Installcableentries
10 Fix the cable entry screws.
11 Fix the DC power cable to the side of the module casing with cable ties.
1.2 Connecting internal optical cablesPurpose
TheopticalcablesconnectedbetweentheSystemModuleandeachoftheRFModulesorRemoteRadioHeads(orthesystemextensionmodule)areusedfortransmittingsignalsbetweenmodules.
TheSystemModulesupportsopticalcablesinthreelengthranges:
1. 0-13km(dependingontheRFHWversion,thevaluesmightvaryasfollows:0-10...13km)
2. 13-26km(dependingontheRFHWversion,thevaluesmightvaryasfollows:10...13kmor20...26km)
3. 26-39km(dependingontheRFHWversion,thevaluesmightvaryasfollows:20...26kmor30...39km)
TheRFModulesmustbeconnectedtotheSystemModulewithafiberfromthesamelengthrange.
NotethatincaseofRFchaining,theopticalcablelengthfromtheSystemModuletoanyRFModuleinchainmustremaininthesamelengthrange.IncaseofRFModuleschaining,thelengthrangeisthetotalopticalpathlengthbetweentheSystemModuleandthelastRFModuleinchain.
SeeContentsoftheFlexiMultiradio10BTSopticalcabledeliveriesandContentsoftheFlexiMultiradio10BTSopticaltransceiverdeliveriesforsupportedcablesandopticaltransceivers.
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
16 DN09107822 Issue:11
-
Before you start
f WARNING! Risk of eye damage caused by invisible laser beam.Makesurethatthelaserbeamisswitchedoffwhenopticalcablesareinstalled.
f CAUTION! Risk of personal injury.Alwaysstoptransmissionbeforedetachingtheopticalfiberfromanopticalfiberconnectormarkedwithawarningtriangle.
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
w NOTICE:Overbendingtheopticalfibercablesdamagesthecablesandcandetachordamagetheconnectors.Donotbendopticalfibrecablestoaradiussmallerthantheminimumradiusof70mm(2.76inches)forcableswithdiameter7mm(0.28inches)or50mm(1.97inches)forcableswithdiameter5mm(0.20inches).
w NOTICE:Theopticalfiberconnectorisfragile.Handleitwithcare.
w NOTICE:Opticalcablesarefragile.Alwaysroutetheopticalcabletothedirectionitisbended.
w NOTICE:Opticalfibersaresensitive.Thepresenceofcontaminantslowersthemechanicalstrengthoftheopticalfiberandmaydampenthetransmissionoflightinthefibers.Cleanallopticalfiberconnectorsbeforeinstallationusinganopticalfibersconnectorcleaningkit.
g WhenusingtwoorthreeparallelopticalfibersperRFModule,thedifferenceinlengthsbetweenthecablesmustnotexceed30m.
w NOTICE:IftheSFPmoduleishotswapped,asiteresetisrequired.
1 Remove the IP seals from the relevant optical cable connectors in both Systemand RF Modules.WhenpullingouttheIPseal,bendingittoanydirectionisonlyallowedforamaximumlengthof2mm(0.08in.).WhentheIPsealhascomeout2mmoutofitsslot,onlyuseaxialforcetocompletetheIPsealremoval.Storethesealsforlateruse.
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 17
-
Figure11 Installingopticaltransceiver
When2mmout,onlyuseaxialforce.
Bendingonlyallowedformax.2mm.
1
2mm
2 Remove the protective cap from the optical transceiver and push it in theSystem Module.
w NOTICE:AlwaysconnectRFModulesusingtheirOPT1porttotheconsecutivemasterSystemModuleports,startingfromRF/EXT1port.MakesureyouinserttheopticaltransceiverasshowninFigure11:Installingopticaltransceiver.Oncetheopticaltransceiverisinserted,flipthelatchup.
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
18 DN09107822 Issue:11
-
3 Pull back the optical cable connector seal to uncover the connector.
Figure12 Pullingbackcableconnectorseal
4 Remove the protective plug and clean the connectors using a reel type opticalfiber connector cleaner or follow the instructions below.
a) Moistenalint-freeswaboronesectionofalint-freewipewithonedropof99%alcohol.
b) Lightlywipetheconnectorwithalcoholmoistenedswaborwipe.c) Dryanyremainingalcoholwithadryswaborthedrysectionofthewipe.d) Properlydisposeoftheswaborwipe.Donotreuse.
5 Connect the cable to the System Module.Makesureitclicksintoplace.
Figure13 Connectingopticalcable
6 Push the connector seal firmly in place.
Figure14 Installingopticalcableconnectorseal
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 19
-
7 Route the cable between the System and RF Modules.
Figure15 Routingopticalcable
Leftside
8 Coil up the excess cable and fix it with cable ties.Youshouldstoreanexcessivecablematerialinacablecoil.Followthestepsbelow.a) Coil the cables according to the specified bending radius.
g Donotexceedtheminimumbendingradiusvalue.b) Support the coil so that the cable own weight does not cause coil to
change its form.c) Store the coil outside in secured location so the weather conditions have
no impact.
9 Remove the protective cap from the optical transceiver and push it in the RFModule.
10 Pull back the optical cable connector seal to uncover the connector.
11 Remove the protective plug and clean the connector according to theinstructions given in step 4.
12 Connect the optical cable to the RF Module.Makesureitclicksintoplace.
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
20 DN09107822 Issue:11
-
13 Push the connector seal firmly in place.
14 Repeat for each RF Module in the configuration.
15 Make sure that all the connector seals are properly installed.
1.3 Connecting transmission cables1.3.1 Overview of connecting transmission cabling
WithFlexiMultiradio10BTSSystemModule,therearethreeoptionsfortransmission:twointegratedinterfacesontheFSMxcoreandanoptionaltransmissionsub-module.
1) EIF1 interface (RJ45)Thisintegratedtransmissioninterfaceismarked"EIF1"ontheFSMxcorefrontpanel.Ifyouareusingthistransmissionoption,seeConnectingRJ45transmissioncable.
2) EIF2 interface (SFP/SFP+)Thisintegratedtransmissioninterfaceismarked"EIF2/RF/6"ontheFSMxfrontpanel.Theinterfacecanbesoftware-configuredtoeitherGEEthernetinterfacefortransportpurposes(SFP)orRP3-01/CPRIinterface(SFP+).Notethatitisonlyavailablefortransportifanoptionaltransmissionsub-moduleisnotdeployed.Ifyouareusingthistransmissionoption,seeConnectingSFPtransmissioncable.
3) Flexi Multiradio 10 BTS optional Transmission Sub-ModuleIfmoreorotherEthernetinterfacesarerequiredthenaFlexiMultiradio10BTSoptionalTransmissionSub-Moduleisneeded.Forinstallationinstructions,seeInstallingFlexiMultiradio10BTSoptionalTransmissionSub-Module(FTIF).Forcablinginstructions,seeConnectingFlexiMultiradio10BTSoptionalTransmissionSub-Module(FTIF)cabling.
SeeContentsoftheFlexiMultiradio10BTStransmissioncabledeliveriesforalistofcablesavailable.
1.3.2 Connecting RJ45 transmission cableBefore you start
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
Summary
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 21
-
w NOTICE:Riskofdamagetoequipment.FlexiBTStransmissioncableswithweather-resistantbootsmustbeusedinoutdoorinstallations.
Figure16 ConnectingRJ45transmissioncable
14
3
2
5
6
1 Remove the IP seal from the EIF1 port on the FSMx core front panel.Storethesealforlateruse.
2 Route the transmission cable through the cable entry.
3 Pull back the connector seal to uncover the connector.
4 Connect the cable to the EIF1 port.Makesureitclicksintoplace.
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
22 DN09107822 Issue:11
-
5 Push the cable connector seal firmly in place.
6 Coil up the excess cable and fix it on the module casing with cable ties.
7 Make sure that the connector seal is properly installed.
1.3.3 Connecting SFP transmission cableBefore you start
f WARNING! Danger of eye damage caused by invisible laser beam.Makesurethatthelaserbeamisswitchedoffduringopticalfiberinstallation.
w NOTICE:OnlyNSNproprietarySFPs(seechapterSmallForm-factorPluggabletransceivers(SFPs)inFlexiMultiradioBaseStationOptionalItemsDescriptionandFlexiMultiradio10BaseStationOptionalItemsDescription)mustbeusedforallopticalconnections(bothsinglemodeandmultimode)toconnectSystemModuleandRadioModule.Anyexceptiontothisrulerequiresawrittenproductmanagementapproval.
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
w NOTICE:Riskofdamagetoequipment.FlexiBTStransmissioncableswithweather-resistantbootsmustbeusedinoutdoorinstallations.
1 Remove the IP seal from the EIF2/RF/6 port on the FSMx core front panel.Storethesealforlateruse.
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 23
-
Figure17 Insertingopticaltransceiver
When2mmout,onlyuseaxialforce.
Bendingonlyallowedformax.2mm.
1
2mm
2 Remove the protective cap from the optical transceiver and push it in theEIF2/RF/6 port.Makesureyouinserttheopticaltransceiverasshownin.Oncetheopticaltransceiverisinserted,flipthelatchup.
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
24 DN09107822 Issue:11
-
3 Route the transmission cable through the cable entry.
4 Pull back the connector seal to uncover the connector.
Figure18 Pullingbacktheconnectorseal
5 Remove the protective plug from the optical cable and clean the connectorusing a reel-type optical connector cleaner or according to the instructionsbelow:
a) Moistenalint-freeswaboronesectionofalint-freewipewithonedropof99%alcohol.
b) Lightlywipetheconnectorwithalcoholmoistenedswaborwipe.c) Dryanyremainingalcoholwithadryswaborthedrysectionofthewipe.d) Properlydisposeoftheswaborwipe.Donotreuse.
6 Connect the cable to the EIF2/RF/6 port.Makesureitclicksintoplace.
Figure19 Connectingopticalcable
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 25
-
Figure20 Connectingopticalcable
7 Push the cable connector seal firmly in place.
Figure21 Pushingtheconnectorsealinplace
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
26 DN09107822 Issue:11
-
8 Coil up the excess cable and fix it on the module casing with cable ties.
9 Make sure that the connector seal is properly installed.
1.4 Connecting FSMx core optional cabling1.4.1 Connecting Sync Out cable
Purpose
Figure22 ConnectingSyncOutcable
1 2 3
1 Remove the IP seal from the Sync Out port on the FSMx core.Storethesealforlateruse.
2 Connect a Sync cable (for example FTSF 472509A) to the Sync Out port.Thecorrectendofthecableismarkedwiththelabel"SyncOut".
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 27
-
3 Push the connector seal firmly in place.
4 Connect the other end of the Sync cable to the Sync In port of the secondFSMx in your configuration.
5 Fix the excess cable with cable ties.
1.4.2 Connecting Sync In cablePurpose
Figure23 ConnectingSyncIncable
1 2 3
Before you start
Theexamplecablesthatcanbeusedarelistedbelow:
Externalsynchronizationinput:
SyncCableF(FTSF472509A) SyncCableG(FTSG472576A)
PoweringandcontrollingGPSequipment:
GPScableassembly30m(FTSE472510A) GPScableassembly100m(FTSH472577A) GPScableassembly300m(FTSM472870A)
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
28 DN09107822 Issue:11
-
1 Remove the IP seal from the Sync In port on the FSMx core.Storethesealforlateruse.
2 Connect the cable to the Sync In port.Thecorrectendofthecableismarkedwiththelabel"SyncIn".
3 Push the connector seal firmly in place.
4 Connect the other end of the cable as follows:
IfyourcableisaFTSF,connectittotheSyncOutportofthesecondFSMFinyourconfiguration.
IfyourcableisaFTSG,connectittotheSyncOutportofFSMC/D/E. IfyourcableisaFTSE/H,connectittotheGPSantenna.
5 Fix the excess cable with cable ties.
1.4.3 Connecting External Alarms and Controls (EAC) cablePurpose
Figure24 ConnectingEACcable
1 2 3
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 29
-
1 Remove the IP seal from the EAC port on the FSMx core.Storethesealforlateruse.
2 Connect an EAC cable (FTSI 472578A) to the EAC port.Thecorrectendofthecableismarkedwiththelabel"EAC".
3 Push the connector seal firmly in place.
4 Connect the other end of the cable to the Flexi System External Alarm module(FSEB).Alternatively,youcancutofftheDconnectorandconnecttheotherendofthecableto,forexample,yourpatchpanelbasedonthecolorcodingofthecable.SeeappendixEACcable(FTSI472578A)wiringfordetails.
5 Fix the excess cable with cable ties.
1.4.4 Connecting external IP devicesPurposeExternalIPdevicescanbeconnectedtoFSMFthroughtheLMPport.Before you start
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
w NOTICE:IfyouconnectRCUAtotheFSMF,connectthedevicethrough10/100Mbitswitch/hub.RCUAworkswith10Mbit/sspeedwithnoautonegotiationsupport.
Summary
ConnectingSystemModule(FSMx)corecabling CablingFlexiMultiradio10BaseStation
30 DN09107822 Issue:11
-
Figure25 ConnectingRJ45cabletoLMPport
4
3
2
5
1
6
1 Remove the IP seal from the LMP port on the FSMx core front panel.Storethesealforlateruse.
2 Route the transmission cable through the cable entry.
3 Pull back the connector seal to uncover the connector.
4 Connect the cable to the LMP port.Makesureitclicksintoplace.
5 Push the cable connector seal firmly in place.
6 Coil up the excess cable and fix it on the module casing with cable ties.
7 Make sure that the connector seal is properly installed.
g AlwaysclosetheIPcapafterdisconnectingthecable.
CablingFlexiMultiradio10BaseStation ConnectingSystemModule(FSMx)corecabling
Issue:11 DN09107822 31
-
2 Connecting Flexi Multiradio 10 BTS PowerDistribution Sub-Module (FPFD) cabling
2.1 FPFD v. 103 cablingBefore you start
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
f WARNING! Risk of short circuit.WhentheFPFDisinuse,itfeeds48VtotheFSMxcoreDCInport.MakesurethattheportiscoveredwiththeIPsealandnotused.DonotalsousetheDCInportforfeedingothermodules.
g ExternalsurgeprotectionisalwaysneededinoutdoorinstallationswithFPFDoutputiftheoutputpowerfeederlengthexceeds10m(installedatFSMFendonly).
Shieldedpowerfeederisalwaysneededinoutdoorinstallationswhenthepowerfeederlengthexceeds4m.Thepowerfeedercableneedstobegroundedatbothends.
IftheDCinputcableisnotconnectedyet,seeInstallingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)fordetails.
Ifcableentriesareinstalled,removethem.
IfyouneedtoconnectDCoutputcablestotheFPFDfrontpanelwhileitisrunning,turnthepowerofffromthecontrolpanel.SeeFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)controlpanelfordetails.
ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
CablingFlexiMultiradio10BaseStation
32 DN09107822 Issue:11
-
1 Undo the screws holding the FSMx core in place and pull it out slightly.
Figure26 PullingFSMxcoreout
2 Loosen the screw terminals on the FPFD front panel with a 2.5mm allen key.
Figure27 LooseningFPFDscrewterminals
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
Issue:11 DN09107822 33
-
3 Strip the DC output cable and wrap tape around the exposed wires in order notto break the IP boot.
Thecablesizeisrangeis4to16mm2(12to6AWG).
Figure28 Wrappingtapearoundwires
4 Insert the taped end of the cable to the IP boot.
Figure29 InsertingcabletoIPboot
ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
CablingFlexiMultiradio10BaseStation
34 DN09107822 Issue:11
-
5 Remove the tape.
Figure30 Removingtape
6 Insert the cable to the screw terminal and make sure that the polarity of thewires is correct.
f WARNING! Risk of power supply failure and, in rare cases, of shortcircuit.Checkthatthepolarityiscorrectaccordingtothemarkingsonthecable.
Figure31 ConnectingFPFDDCoutputcablewires_+
7 Tighten the screw terminals to 3.0 Nm (2.21 ft-lb).MakesurethattheDCcableisnotbenttotheleftorrightinordertoavoidtensiontotheDCoutputterminals.
Figure32 TighteningFPFDscrewterminals
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
Issue:11 DN09107822 35
-
8 Fix the IP boot in place.
Figure33 FixingIPboot
ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
CablingFlexiMultiradio10BaseStation
36 DN09107822 Issue:11
-
9 Repeat steps 2 to 8 as many times as necessary.
10 Reinsert the FSMx core and fix the screws.
2.2 FPFD v. 204 Efore cablingBefore you start
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
w Separatetheinputcabletopositiveandnegativewires(accordingtotheirelectricalpolarity).Outputwireshavetobeplacedinsideroundjacket.
f WARNING! Risk of short circuit.WhentheFPFDisinuse,itfeeds48VtotheFSMxcoreDCInport.MakesurethattheportiscoveredwiththeIPsealandnotused.DonotalsousetheDCInportforfeedingothermodules.
g ExternalsurgeprotectionisalwaysneededforoutdoorinstallationswithFPFDoutputiftheoutputpowerfeederlengthexceeds10m(installedattheFSMFendonly).
Shieldedpowerfeederisalwaysneededforoutdoorinstallationswhenthepowerfeederlengthexceeds4m.Thepowerfeedercableneedstobegroundedatbothends.
w ConductorwirediameterofDCcableneedstobeselectedbasedonthePDUFuserating.OVPDCampacityshallnotbelowerthanthePDUFuserating.FornewerFPFDPDUversionA.204with43Alabel,asingleDCcableissufficientanddualDCcableFPCAmustnotbeused.
IftheDCinputcableisnotconnectedyet,seeInstallingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)fordetails.
Ifcableentriesareinstalled,removethem.
IfyouneedtoconnectDCoutputcablestotheFPFDfrontpanelwhileitisrunning,turnthepowerofffromthecontrolpanel.SeeFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)controlpanelfordetails.
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
Issue:11 DN09107822 37
-
1 Loosen the screw terminals on the FPFD front panel with a TX25 tool.
Figure34 LooseningFPFDscrewterminals
2 Strip 10 mm of insulation off the DC output cable and wrap exposed wires withtape in order not to break the IP boot.
Thecablesizerangeis10to16mm2(7to6AWG).
Figure35 Wrappingtapearoundwires
ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
CablingFlexiMultiradio10BaseStation
38 DN09107822 Issue:11
-
3 Cut the tip of the IP boot with scissors according to your cable diameter.
4 Insert the taped end of the cable to the IP boot.
Figure36 InsertingcabletoIPboot
5 Remove the tape.
Figure37 Removingtape
6 Insert the cable to the screw terminal and make sure that the polarity of thewires is correct.
f WARNING! Risk of power supply failure and, in rare cases, of shortcircuit.Makesurethatthepolarityiscorrectaccordingtothemarkingsonthecable.
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
Issue:11 DN09107822 39
-
Figure38 ConnectingFPFDDCoutputcablewires
+-
7 Tighten the screw terminals to 3.0 Nm (2.21 ft-lb).MakesurethattheDCcableisnotbenttotheleftorrightinordertoavoidtensiontotheDCoutputterminals.
w NOTICE:Themaximumtorqueis4.0Nm(2.95ft-lb).Donotovertighten.
Figure39 TighteningFPFDscrewterminals
ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
CablingFlexiMultiradio10BaseStation
40 DN09107822 Issue:11
-
8 Fix the IP boot in place.
Figure40 FixingIPboot
+-
9 Repeat steps 2 to 8 as many times as necessary.
2.3 FPFD v. 204 Artesyn cablingBefore you start
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
Issue:11 DN09107822 41
-
w Separatetheinputcabletopositiveandnegativewires(accordingtotheirelectricalpolarity).Outputwireshavetobeplacedinsideroundjacket.
f WARNING! Risk of short circuit.WhentheFPFDisinuse,itfeeds48VtotheFSMxcoreDCInport.MakesurethattheportiscoveredwiththeIPsealandnotused.DonotalsousetheDCInportforfeedingothermodules.
g ExternalsurgeprotectionisalwaysneededforoutdoorinstallationswithFPFDoutputiftheoutputpowerfeederlengthexceeds10m(installedatFSMFendonly).
Shieldedpowerfeederisalwaysneededforoutdoorinstallationswhenthepowerfeederlengthexceeds4m.Thepowerfeedercableneedstobegroundedatbothends.
w ConductorwirediameterofDCcableneedstobeselectedbasedonthePDUFuserating.OVPDCampacityshallnotbelowerthanthePDUFuserating.FornewerFPFDPDUversionA.204with43Alabel,asingleDCcableissufficientanddualDCcableFPCAmustnotbeused.
IftheDCinputcableisnotconnectedyet,seeInstallingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)fordetails.
Ifcableentriesareinstalled,removethem.
IfyouneedtoconnectDCoutputcablestotheFPFDfrontpanelwhileitisrunning,turnthepowerofffromthecontrolpanel.SeeFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)controlpanelfordetails.
1 Loosen the screw terminals on the FPFD front panel with a TX25 tool.
Figure41 LooseningFPFDscrewterminals
ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
CablingFlexiMultiradio10BaseStation
42 DN09107822 Issue:11
-
2 Strip 10 mm of insulation off the DC output cable and wrap the exposed wireswith tape in order not to break the IP boot.
Thecablesizeisrangeis10to16mm2(7to6AWG).
Figure42 Wrappingtapearoundwires
3 Cut the tip of the IP boot with scissors according to your cable size.
4 Insert the taped end of the cable to the IP boot.
Figure43 InsertingcabletoIPboot
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
Issue:11 DN09107822 43
-
5 Remove the tape.
Figure44 Removingtape
6 Insert the cable to the screw terminal and make sure that the polarity of thewires is correct.
f WARNING! Risk of power supply failure and, in rare cases, of shortcircuit.Makesurethatthepolarityiscorrectaccordingtothemarkingsonthecable.
Figure45 ConnectingFPFDDCoutputcablewires
+-
7 Tighten the screw terminals to 3.0 Nm (2.21 ft-lb).MakesurethattheDCcableisnotbenttotheleftorrightinordertoavoidtensiontotheDCoutputterminals.
ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
CablingFlexiMultiradio10BaseStation
44 DN09107822 Issue:11
-
Figure46 TighteningFPFDscrewterminals
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
Issue:11 DN09107822 45
-
8 Fix the IP boot in place.
Figure47 FixingIPboot
+-
9 Repeat steps 2 to 8 as many times as necessary.
ConnectingFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD)cabling
CablingFlexiMultiradio10BaseStation
46 DN09107822 Issue:11
-
3 Connecting Flexi Multiradio 10 BTS optionalTransmission Sub-Module (FTIF) cablingBefore you start
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
w NOTICE:IftheSFPmoduleishotswappedasiteresetisrequired.
Summary
Figure48 ConnectingFTIFcabling
7
1 2
IfusingOPT Ifs:
3
6
4
8
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSoptionalTransmissionSub-Module(FTIF)cabling
Issue:11 DN09107822 47
-
1 Remove IP seals from the relevant transmission sub-module ports.Storethesealsforlateruse.
2 If using the optical interfaces, insert SFP modules to the EIF1 and EIF2 ports.UseonlyrecommendedSFPmodules.
w NOTICE:IftheSFPmoduleishotswappedasiteresetisrequired.
3 Route a transmission cable through the cable entry.
4 Pull back the connector seal covering the transmission cable connector.
5 If using the optical interfaces, clean the optical cables before connecting them.SeeConnectinginternalopticalcablesforinstructions.
6 Connect the cable to the transmission sub-module.
7 Push the cable connector seal firmly in place.
8 Coil up the excess cable and fix it on the module casing with cable ties.
9 Repeat steps 3-8 for all the transmission cables required for yourconfiguration.
10 Make sure that all the connector seals are properly installed.
ConnectingFlexiMultiradio10BTSoptionalTransmissionSub-Module(FTIF)cabling
CablingFlexiMultiradio10BaseStation
48 DN09107822 Issue:11
-
4 Connecting Flexi Multiradio 10 BTS CapacityExtension Sub-Module (FBBA) cablingBefore you start
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
1 Remove IP seals from the FBBA ports that you are going to use.Storethesealsforlateruse.
Figure49 RemovingFBBAIPseals
2 Connect the power cable (995297) from the DC out port on the FSMx core tothe DC in port on the FBBA front panel.Makesureitclicksintoplace.
Figure50 Connectingpowercable
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSCapacityExtensionSub-Module(FBBA)cabling
Issue:11 DN09107822 49
-
3 Push the connector seals firmly in place.
4 If using two FBBA sub-modules, chain the power cable from the DC out port ofthe first FBBA to the DC in port of the second FBBA.
Figure51 Chainingpowercable
5 Push the connector seals firmly in place.
6 Connect a QSFP cable (995298) from the BB EXT1 port on the FSMx core to theBB EXT port on the FBBA front panel.
w NOTICE:MakesurethepowercableisconnectedbeforeconnectingtheQSFPcable.Makesureitclicksintoplace.
Figure52 ConnectingQSFPcable
ConnectingFlexiMultiradio10BTSCapacityExtensionSub-Module(FBBA)cabling
CablingFlexiMultiradio10BaseStation
50 DN09107822 Issue:11
-
7 Push the connector seals firmly in place.
8 If using two FBBA sub-modules, connect a QSFP cable (995298) from the BBEXT2 port on the FSMx core to the BB EXT port of the second FBBA.
Figure53 ConnectingsecondQSPFcable
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSCapacityExtensionSub-Module(FBBA)cabling
Issue:11 DN09107822 51
-
9 Push the connector seals firmly in place.
10 Make sure that all the connector seals are properly installed.
11 If applicable, install a front cover on the FSMx.
w NOTICE:Donotbreakthemaximumbendingradiusof40mm(1.57in.)fortheQSFPcables.BendthecablesupwardsasshowninFigure54:BendingtheQSFPcables(1)andFigure55:BendingtheQSFPcables(2),ensuringthattheouteredgesofthecablesarewithinthefrontcoverinnerdimensions.
Figure54 BendingtheQSFPcables(1)
Figure55 BendingtheQSFPcables(2)
ConnectingFlexiMultiradio10BTSCapacityExtensionSub-Module(FBBA)cabling
CablingFlexiMultiradio10BaseStation
52 DN09107822 Issue:11
-
5 Connecting Flexi Multiradio 10 BTS CapacityExtension Sub-Module (FBBC) cablingBefore you start
w NOTICE:Incorrectcablesandsealsmaynotprovideappropriateingressprotection.UseonlytestedIP65classoutdoorcableswithsealsprovidedbyNSN.Thisisrequiredforbothindoorandoutdoorinstallations,includingtheoutdoorcabinet.
1 Remove IP seals from the DC power cable and FBBC ports that you are goingto use.Storethesealsforlateruse.
Figure56 RemovingFBBCIPseals
2 Follow steps below to connect the DC power cable:
Figure57 Connectingpowercable
A
C B
a) Connect the cable to the DC out port on the FSMx core.
w InstalltheDCcablesothattext"Thissideup"isfacingupwards.
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSCapacityExtensionSub-Module(FBBC)cabling
Issue:11 DN09107822 53
-
b) If using two FBBC sub-modules, connect the cable to the DC IN port of theright FBBC sub-module.
w IfusingonlyoneFBBCsub-module,leavetheprotectivecapontheunusedpowerconnectoroftheDCpowercable.c) Connect the cable to the DC IN port of the left FBBC sub-module.
3 Push the connector seals firmly in place.
4 Connect a QSFP cable (995298) from the BB EXT1 port on the FSMx core to theBB EXT port on the FBBC front panel.
w NOTICE:MakesurethepowercableisconnectedbeforeconnectingtheQSFPcable.Makesureitclicksintoplace.
Figure58 ConnectingQSFPcable
ConnectingFlexiMultiradio10BTSCapacityExtensionSub-Module(FBBC)cabling
CablingFlexiMultiradio10BaseStation
54 DN09107822 Issue:11
-
5 Push the connector seals firmly in place.
6 If using two FBBC sub-modules, connect a QSFP cable (995298) from the BBEXT2 port on the FSMx core to the BB EXT port of the second FBBC.
Figure59 ConnectingsecondQSFPcable
CablingFlexiMultiradio10BaseStation ConnectingFlexiMultiradio10BTSCapacityExtensionSub-Module(FBBC)cabling
Issue:11 DN09107822 55
-
7 Push the connector seals firmly in place.
8 Make sure that all the connector seals are properly installed.
9 If applicable, install a front cover on the FSMx.
w NOTICE:Donotbreakthemaximumbendingradiusof40mm(1.57in.)fortheQSFPcables.BendthecablesupwardsasshowninFigure60:BendingtheQSFPcables(1)andFigure61:BendingtheQSFPcables(2),ensuringthattheouteredgesofthecablesarewithinthefrontcoverinnerdimensions.
Figure60 BendingtheQSFPcables(1)
Figure61 BendingtheQSFPcables(2)
ConnectingFlexiMultiradio10BTSCapacityExtensionSub-Module(FBBC)cabling
CablingFlexiMultiradio10BaseStation
56 DN09107822 Issue:11
-
6 Checklist for cabling Flexi Multiradio 10 BTS
Work phase
Checked
Groundingcableisconnected.
Internalpowercablesareconnected.
Opticalcablesarecleanedandconnected.
Transmissioncablesareconnected.
Optionalcablesareconnected.
Allcableconnectorsealsarefirmlyinplace.
UnusedconnectorsarecoveredwithIPseals.
OnlyNSNprovidedcablesareused.
Modulefrontpanelcoversareinstalled.
CablingFlexiMultiradio10BaseStation ChecklistforcablingFlexiMultiradio10BTS
Issue:11 DN09107822 57
-
7 Appendices
7.1 Contents of the Flexi Multiradio 10 BTS opticalcable deliveriesTheFlexiMultiradio10BTSexemplaryopticalcablesarelistedinTable2:Opticalcabledeliveries.
Table2 Opticalcabledeliveries
Cable type
Product code
Description
FSFOFlexiSystemFibreHF2m
471851A Halogenfree,2LCconnectorsand2rubbergaskets
FSFDFlexiSystemFibreD4m
471743A 2LCconnectorsand2rubbergaskets
FSFFFlexiSystemFibreF10m
471707A 2LCconnectorsand2rubbergaskets
FSFGFlexiSystemFibreG20m
471708A 2LCconnectorsand2rubbergaskets
FSFHFlexiSystemFibreH30m
471709A 2LCconnectorsand2rubbergaskets
FSFIFlexiSystemFibreI40m
471710A 2LCconnectorsand2rubbergaskets
FSFBFlexiSystemFibreB50m
471395A 2LCconnectorsand2rubbergaskets
FSFQFlexiSystemFibreHF50m
471852A Halogenfree,2LCconnectorsand2rubbergaskets
FSFKFlexiSystemFibreK75m
471711A 2LCconnectorsand2rubbergaskets
FSFCFlexiSystemFibreC100m
471396A 2LCconnectorsand2rubbergaskets
FSFPFlexiSystemFibreP200m
471712A 2LCconnectorsand2rubbergaskets
Appendices CablingFlexiMultiradio10BaseStation
58 DN09107822 Issue:11
-
7.2 Contents of the Flexi Multiradio 10 BTS opticaltransceiver deliveriesTheFlexiMultiradio10BTSexemplaryopticaltransceiversarelistedinTable3:Opticaltransceiverdeliveries.
Table3 Opticaltransceiverdeliveries
Cable type
Product code
Description
FOSDFlexiOpticalTelecomSFPGbE850nmMM
471881A SFPTransceiver1000Base-SXEthernet,wave-length850nm,shorthaul
FOSCFlexiOpticalTelecomSFPGbE1310nm
471880A SFPTransceiver1000Base-LXEthernet,Wavelength1310nm,suitablee.g.forFTCH,longhaul
7.3 Contents of the Flexi Multiradio 10 BTStransmission cable deliveriesTheFlexiMultiradio10BTSexemplarytransmissioncablesarelistedinTable4:Transmissioncabledeliveries.
Table4 Transmissioncabledeliveries
Cable type
Product code
Description
FTCYODCableRJ48CCAT715m
472427A Dualtwistedpaircablefor2xE1,oneendwithRJ48Candrubbergasket
FTCBODCableRJ48C120ohm15m
470309A Twistedpaircablefor1xE1,oneendwithRJ48Candrubbergasket
FTCVODCableRJ48C120ohm30m
471713A Twistedpaircablefor1xE1,oneendwithRJ48Candrubbergasket
FTCXODCableRJ48C120ohm50m
471714A Twistedpaircablefor1xE1,oneendwithRJ48Candrubbergasket
CablingFlexiMultiradio10BaseStation Appendices
Issue:11 DN09107822 59
-
Table4 Transmissioncabledeliveries(Cont.)
Cable type
Product code
Description
FTCHODCableLCSM131015m
470311A Opticalfiberwith2xLCconnectorandonerubbergasket
FTCRODCableRJ45CAT5E15m
471408A TwistedpaircableforGE,oneendwithRJ45andrubbergasket
FTCSODCableRJ45CAT5E30m
471717A TwistedpaircableforGE,oneendwithRJ45andrubbergasket
FTCTODCableRJ45CAT5E50m
471718A TwistedpaircableforGE,oneendwithRJ45andrubbergasket
FTCLODCableRJ48C-RJ48C120ohm4m
472348A Twistedpaircablefor1xE1,bothendswithRJ48Candrubbergaskets
FTCWODCableRJ45-RJ45CAT5E4m
472347A TwistedpaircableforGE,bothendswithRJ45andrubbergaskets
FTCAODCableRJ48C-TQ-M/0120ohm5m
470312A Pre-fabricatedco-locationcableforUltraSite,RJ48CtoTQconnector,for1xE1withonerubbergasket
7.4 Contents of the Flexi Multiradio 10 BTSsynchronization cable deliveriesTheFlexiMultiradio10BTSexemplarysynchronizationcablesarelistedinTable5:Synccabledeliveries.
Table5 Synccabledeliveries
Cable type
Product code
Description
FTSFSyncCableF 472509A 2xHDMIconnectorwithrubbergasketstoconnectSyncIn/OutportsofcollocatedFSMF
Appendices CablingFlexiMultiradio10BaseStation
60 DN09107822 Issue:11
-
Table5 Synccabledeliveries(Cont.)
Cable type
Product code
Description
FTSGSyncCableG 472576A S1xHDMIandoneMDR14connectorwithrubbergasketstoconnectFSMFSyncIntoe.g.FSMESyncOutport
7.5 EAC cable (FTSI 472578A) wiringTable6 EACcable(FTSI)wiring
Conn. 1 (HDMI)
Pin no.
Conn. 2 (D37)
Pin no.
Pair: wire color
Description
1 7 1:Black EXT_AL0_H
2 8 2:Brown EXT_AL1_H
3 9 1:White/Black EXT_AL2_H
4 10 2:White/Brown EXT_AL3_H
5 11 3:Red EXT_AL4_H
6 12 4:Orange EXT_AL5_H
7 1+13 3:White/Red EXT_CTRL0_EXT_AL6_H
8 2+14 4:White/Orange EXT_CTRL1_EXT_AL7_H
9 3+15 5:Yellow EXT_CTRL2_EXT_AL8_H
10 4+16 6:Green EXT_CTRL3_EXT_AL9_H
11 5+17 5:White/Yellow EXT_CTRL4_EXT_AL10_H
12 6+18 6:White/Green EXT_CTRL5_EXT_AL11_H
13 19 7:Blue P5V0_EAC
CablingFlexiMultiradio10BaseStation Appendices
Issue:11 DN09107822 61
-
Table6 EACcable(FTSI)wiring(Cont.)
Conn. 1 (HDMI)
Pin no.
Conn. 2 (D37)
Pin no.
Pair: wire color
Description
14 20 7:White/Blue P5V0_EAC
15 23 8:Violet PROT_CAN_H_P5V_EAC
16 27 9:Grey GND
17 24 8:White/Violet PROT_CAN_L_P5V_EAC
18 25 10:Pink GND
19 28 9:White/Grey GND
7.6 Flexi Multiradio 10 BTS Power Distribution Sub-Module (FPFD) control panelThecontrolpanelislocatedonthefrontpaneloftheFlexiMultiradio10BTSPowerDistributionSub-Module(FPFD).TherearefiveLEDsforthecorrespondingoutputports,andtwopushbuttonsfortheON/OFFfunctionalityofthetheoutputs.
Figure62 FPFDcontrolpanel
RF1 RF2 RF3 RF4 SYS
SETSELECT
Appendices CablingFlexiMultiradio10BaseStation
62 DN09107822 Issue:11
-
Table7 FPFDLEDindications
LED color
Function of theoutput
Fault caused by
Nocolor Outputisdisabled -
Yellow Stand-by,outputdisabled
Waitingforretry
Overload,overtemperatureorshortcircuit>Automaticrestart
Green Normaloperation,outputenabled
-
Red Fault,outputdisabled Overloadorshortcircuit>RemainsOFFafterfault
Blinkingred Fuse#1willremaindisabled.Fuse#2tofuse#5onlysignalingfunction.
Reversepolarityorfeed-inintooutput
Allblinkingred Alloutputsdisabledafterpoweron
Internalhardwarefailureindication
Blinkingyellow Remotecontrolled,outputdisabled
-
Blinkingblue Selectionphaseactive
-
No function (neutral):PushingtheSETbuttonoutsidetheselectionphasedoesnotdoanything.
Entering selection phase (neutral):PushingtheSELECTbuttonentersorresumestheselectionphase.Startingattheleftmostposition(RF1)theLEDstartsblinkinginbluecolor(bluecolorisnotusedforanyotherkindofsignaling).WitheachadditionalpushontheSELECTbuttontheblinkingpositionmovesforwardfromthelefttorightpositioninacircularway.Theselectionphaseendsautomaticallyafterthreesecondswhennobuttonhasbeenpushedwithinthistimeframe.
Changing output state:PushingtheSETbuttonduringtheselectionphasetogglestheselected(blinkingblue)outputstate.AslongastheselectionphaseisactiveyoucantoggletheoutputstatewitheachpushontheSETbutton.WhentogglingtheoutputstatetoONtheselectionphaseisextendedtofivesecondstogivetheuserenoughtimetotoggletoOFFagain(incaseoftargetdevicemalfunction).
CablingFlexiMultiradio10BaseStation Appendices
Issue:11 DN09107822 63
-
Restrictions:TheSETpushbuttoncanbere-routedtotheSystemModule.ThisallowstheSystemModuletojudgeovertheON/OFFfunctionalityviathepushbutton.Defaultsetupisnore-routing.
ViaprioritycontrollinginFPFDitcanbeprohibitedtoalteranoutputstateviathepushbuttonwhenahigherpriorityaccesslinehastakenoverthecontrolforaspecificoutput.Defaultsetupisallaccesslineshavethesameprioritylevel.
OnlyimplementedordetectedoutputscanbeselectedviatheSELECTbutton.
Appendices CablingFlexiMultiradio10BaseStation
64 DN09107822 Issue:11
Cabling Flexi Multiradio 10 Base StationTable of ContentsList of FiguresList of TablesSummary of changes1Connecting System Module (FSMx) core cabling1.1Connecting external power feed1.2Connecting internal optical cables1.3Connecting transmission cables1.3.1Overview of connecting transmission cabling1.3.2Connecting RJ45 transmission cable1.3.3Connecting SFP transmission cable
1.4Connecting FSMx core optional cabling1.4.1Connecting Sync Out cable1.4.2Connecting Sync In cable1.4.3Connecting External Alarms and Controls (EAC) cable1.4.4Connecting external IP devices
2Connecting Flexi Multiradio 10 BTS Power Distribution Sub-Module (FPFD) cabling2.1FPFD v. 103 cabling2.2FPFD v. 204 Efore cabling2.3FPFD v. 204 Artesyn cabling
3Connecting Flexi Multiradio 10 BTS optional Transmission Sub-Module (FTIF) cabling4Connecting Flexi Multiradio 10 BTS Capacity Extension Sub-Module (FBBA) cabling5Connecting Flexi Multiradio 10 BTS Capacity Extension Sub-Module (FBBC) cabling6Checklist for cabling Flexi Multiradio 10 BTS7Appendices7.1Contents of the Flexi Multiradio 10 BTS optical cable deliveries7.2Contents of the Flexi Multiradio 10 BTS optical transceiver deliveries7.3Contents of the Flexi Multiradio 10 BTS transmission cable deliveries7.4Contents of the Flexi Multiradio 10 BTS synchronization cable deliveries7.5EAC cable (FTSI 472578A) wiring7.6Flexi Multiradio 10 BTS Power Distribution Sub-Module (FPFD) control panel