CABLE-TV NETWORKS: HFC PRODUCTS &...
Transcript of CABLE-TV NETWORKS: HFC PRODUCTS &...
3
TYPE DESCRIPTION PAGE
DELTANET Monitoring Software solution 4
Overview Amplifiers 1 GHz 9
Overview Amplifier Plug-In modules 10
BKE-P/BKE-PS House amplifier Profi-Line 1GHz 11
BKD-SF House amplifier Profi-Line 1GHz 13
LHE-P Line- and Distributionamplifier 1GHz 14
LHE Line- and Distributionamplifier 1GHz 16
LHD Line- and Distributionamplifier 1GHz 18
NVD-ED Line- and Distributionamplifier Expert-Line 1GHz 20
Overview Amplifiers 1.2 GHz 23
Overview Amplifier Plug-In modules 24
BKD G House amplifier Profi-Line 1,2GHz 25
LHD G/GR Line- and Distributionamplifier 1,2GHz 27
NVD G/GR Line- and Distributionamplifier Expert-Line 1,2GHz 29
GE Gain Extender 1,2 GHz 32
AGC/VM/AM System modules for Line- and Distributionamplifier 33
RV Return way modul for House amplifier 34
RLK Return way modul for Line- and Distributionamplifier 34
LPF/HPF Low- and Highpass Filter 35
NHP Return way - Ingressfilter 35
PAD/PAD-L JXP-PAD’s attenution 36
PG Connectors, Accessories 37
HÜP BK-Networktermination point Profi-Line 38
ZGV-A 2-way apartment-amplifier 39
4
DELTANET INTELLIGENT MONITORING SOFTWARE SOLUTION
DELTANET NMS software for monitoring and troubleshooting your FTTx and cable networks Powerful non-proprietary monitoring software to manage your network
HJ Module-oriented NMS-solution for: HFC, fibre optics, FOSTRA-F, FOSTRA-D, head end devices, provisioning
HJ Graphical user interface for display of all parameters of your net-work and the network topology
HJ Automatic analysis feature for ingress fighting and error analysis in collaboration with our managed components
HJ A highly powerful analysis tool lets you quickly locate sources of interference on the network by evaluation of important parameters of the CMTS and the cable modem in conjunction with managed components.
HJ Supported standards and protocols: SNMP, SOAP, HTTP, Telnet, XML, XSLT and JavaHJ Integration and capture of your managed components in the
DELTANET is possible with intelligent Smart Phone Application (FOSTRA-F) in conjunction with a database system – this saves the installer considerable time during commissioning while visuali-zation is made within a few minutes
HJ Take advantage of our sophisticated service and software maintenance system
HJ DELTANET is suitable for FOSTRA-F, FOSTRA-D – but also for the integration of multi-vendor components
HJ FOSTRA-F = FSK-Monitoring FOSTRA-D = DOCSIS-Monitoring
5
HFC-
COM
PON
ENTS
SNMP clientwww client
SNMP clientwww client
HEC(open socket)
SNMP clientwww client
SNMP clientwww client
Server, DB(Web server, SNMP server)
…
Fostra-F endpoints
Fostra-F endpoints
Fostra-F endpoints
Data base synch. MAC-Adr. scan
Position
DELTANET NMS software for monitoring and troubleshooting your FTTx and cable networks Powerful non-proprietary monitoring software to manage your network
HJ A smartphone or tablet PC connection via our app provides an auto-mated collection of your device locations
HJ With the App, a system check in relation with the head-end control-ler and DELTANET is possible in field
HJ Systematic recording of location data and documentation of the settings parameters of your network componentsHJ Access to DELTANET via internet connection HJ Device control by Android App: DELTA amplifier and
DELTA nodes
6
FOSTRA-F NETWORK MONITORING
Head End Controller für FOSTRA-F Cost-effective monitoring system for RFoG nodes and amplifiers to manage you network
HJ Head End Controller in operation with FOSTRA-F and DELTANET NMS-Software acc. to EN 60728-14
HJ Compact FSK-transmitter 19“, 1RU standard housingHJ Transmit frequency 868.3 MHz HJ Web server with DELTANET application, Linux operatedHJ 4 outputs with RF testpoint, optimal cluster splitting possibleHJ Electronic level adjustment of each outputHJ 10Base-T RJ-45 connection, USB-port
Application
Article-No.
TX-frequency MHz
Monitoring-Status LED
Bandwidth kHz
Spurious dBµV
Distortion dB
Transmitting level dBµV
RF test point
Data Speed Bps
Local Interface
Power supply V~/W
Dimensions mm
Weight kg
DELTANET / FOSTRA-F
5700 2115
868.3 MHz (other frequencies on request)
green
200
< 10
> 66
4 x 75...105 (set up by software)
4x-20dB
9600
10 Base-T RJ-45 and USB
185...265 / < 10
19“, 1 HE 482 x 260 x 44 / IP 20, In-door
2.0
Type HEC-1004
7
HFC-
COM
PON
ENTS
FOSTRA-F NETWORK MONITORING
FOSTRA-F Microreceiver for Fibre Nodes and Amplifiers Cost-effective monitoring system for RFoG nodes and amplifiers to manage your network
HJ FSK Microreceiver in operation with HEC 1004 and DELTANET NMS-Software acc. EN 60728-14
HJ Plug-able module for: ONH, ONB, BKD, LHD, NVD Typen (latest generation)HJ RX frequency 868.3 MHz HJ Monitoring status LED for displaying operation modeHJ Monitoring functions: DS ON/OFF, Burst Mode ON/OFF,
Ingress Detection Switch 0 / 6 / 45 dBHJ Intelligent integration into DELTANET via Smart Phone
applicationHJ Very low power consumption and cost-effective solution
for monitoring your network
Application
Article-No.
RX frequency MHz
Monitoring-Status LED
Bandwidth kHz
Spurious dBµV
Dynamic-Input level dBµV
Data Speed Bps
Local Interface
Power supply V~/W
Dimensions mm
Weight kg
ONH, ONB, BKD, LHD, NVD types (latest generation)
5700 1981
868,3 MHz (other frequencies on request)
green: 0 / 6 / 45dB, DS ON/OFF, Burst Mode ON/OFF
200
< 10
30...75
9600
RS-232
6-24V / < 0,4W@24V / <0.18W@12V
25 x 24 x 8
0.02
Typee FOSTRA-F
8
FOSTRA-D NETWORK MONITORING
FOSTRA-D- Kit DOCSIS Monitoring System for nodes and ampliifers to manage your network
HJ EURODOCSIS 2.0 Transponder in operation with DELTANET NMS-Software, SNMP capable
HJ Modular plugable: LHD, NVD types
HJ Monitoring status LED for displaying operation modeHJ Monitoring function: RX, TX Pegel, SNR, BER
Ingress Detection Switch 0 / 6 / 45 dB, otherHJ Intelligent integration into DELTANET via Smart Phone
applicationHJ Web-Gui https, RJ-45 connector, HMS MIB‘s available
Type Fostra D Kit I
NVD types
5700 2329
5-65 / 50-930
RX/TX/connect
0.2 / 6-8
2-256QAM / 4-1024 QAM
8...58 / -15...+15
10/100 Mbps
RJ 45
3.3V / 3.5W
80 x 50 x 10 / 0.02
Application
Article-No.
RX Frequencyrange US / DS MHz
Monitoring-Status LED
Bandwidth US / DS MHz
Modulation US / DS
RF-level TX / RX dBmV
Ethernet 10BaseT
Local Interface
Power supply V / W
Dimensions/Weight mm/kg
Fostra D Kit II*
LHD types
5700 2330
5-65 / 50-930
RX/TX/connect
0.2 / 6-8
2-256QAM / 4-1024 QAM
8...58 / -15...+15
10/100 Mbps
RJ 45
3.3V / 3.5W
80 x 50 x 10 / 0.02
* Fostra D Kit II with adapterboard and assembling kit
9
HFC-
COM
PON
ENTS
OVERVIEW AMPLIFIERS 1 GHzHouse amplifiers
Product family
BK
98 - 106
active, on board
PAD-JXP
F-connector
W / –
BK
99 - 109
active, modular
Step-Spin
F-connector
W / –
BKE-PS BKD-SF LHE-P
BK
110
active, on board
PAD-JXP
F-connector
W /–
Application
Output level dBuV (CTB/CSO > 60 dB)
Return way 65 MHz
Adjustments
RF-connections
Local / remote feeding
BKE-P
BK
98 - 101
active, on board
variable level attn.
F-connector
W / –
BKE-Series: PS: adjustments with variable level attenuators: no accessories needed for operation; P: adjustments with PAD’s: JXP PAD‘s needed for operation, values readableBKD-Series: SF: 1 GHz house amplifier, modular active return way, Step Spin adjustments: simply value adjustment and values directly readable, no accessories needed for operation, IDS – Ingress Detection Switch, FOSTRA-F compliant
Line extender- and Distribution amplifier
Type
Line extender and
distribution amplifier
110
1 / 2
electronical
active, on board
PG 11 oder 5/8”
W /W
LHE
Line extender and
distribution amplifier
110
1 / 2
electronical
active, modular
PG 11 oder 5/8”
W /W
LHD
Networkmanagement-
compl. distribution amplifier
2x114
2 / 2
electronical
active, modular
PG 11 oder 5/8”
W /W
NVD
Application
Output level dBuV (CTB/CSO > 60 dB)
No. of outputs
Adjustments
Return way
RF-connections
Local / remote feeding
Line extender- and Distribution amplifier LHE / LHD: Distribution amplifier NVD:FOSTRA-F and partially FOSTRA-D compliant; IDS – Ingress Detection Switch (partially) 2 active outputs possible; modulare return way Remote pwr. 10A depending on model; protection class IP 65 FOSTRA-F and FOSTRA-D compliant Remote pwr. 10A; protection class IP 65
10
HJ In the table hereafter the plug-ins for the following products are listed: HJ Amplifier: BKD-SF, LHD, NVD
OVERVIEW AMPLIFIER PLUG-IN MODULES
RLK 565
HPF 85-1
LPF 5-65
RLK 585
HPF 105-1
LPF 5-85
NHP 15-1
RV 65-22 EF
RV 65-32 EF
FOSTRA-F
FOSTRA-D Kit I
FOSTRA-D Kit II
VM 302
VM 202-2
AM 301-10 A
AM 301-10 B
AGC 203-1
AGC 303
AGC 403
Types NVD 9240 ED
Diplexer 65/85 MHz
Highpass Filter 85 MHz
Lowpass Filter 65 MHz
Diplexer 85/105 MHz
Highpass Filter 105 MHz
Lowpass Filter 85 MHz
Ingress-Filter 15 MHz
RW-Module 22dB
RW-Module 32dB
FSK-Tr.
DOCSIS-Tr.
DOCSIS-Tr.
2-way splitter
2-way splitter
Tap 10 dB Line out
Tap. 10 dB Tap out
AGC-Module
AGC-Module
AGC-Module
LHD 41 LHD 41 ED
5700 2095
5700 2297
5700 2295
5700 2096
5700 2298
5700 2296
5700 2116
5700 2432
5700 1956
5700 1981
5700 2329
5700 2330
5700 2092
5700 1674
5700 2093
5700 2117
5700 2054
5700 2091
5700 2493
BKD-SF LHE 40
1 GHz - Amplifiers
Article No. Description
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Glossar y
JXP-PADs required for adjustment
Variable level attenuator included, no additional accessories required for level adjustment
Step-Spin adjustment, precise step control, values readable
Electronical adjustment, display, key pad, precise step control, values readable
1,2 GHz technology, DOCSIS 3.1 compliant
Remote management using FOSTRA-TechnologyFOSTRA-F FSK Monitoring FOSTRA-D DOCSIS Monitoring
1.2G
W
W
W
W
W
W
W
W
W
W
W
W
W
W
11
HFC-
COM
PON
ENTS
HOUSE AMPLIFIER PROFI-LINE BKE-PS
HJ KDG amplifier models are listed in the table below from model year 2014 on
HJ BKE-PS amplfier: return way on boardHJ Precise and reliable adjustments by variable level attn. (PS)
for level and slope controlHJ Low noiseHJ LED indicator for operation status HJ Kabel Deutschland certified
Types: BKE-PS
Article-No.
Description
Frequency range US / DS MHz
Gain US / DS dB
Adj. level/slope DS dB
Interstage slope DS (Jumper)
Noise US/DS dB
Output level CENLEC42 flat dBµV
Return way (KDG 1TS140) dB
Level adjustment US dB
Slope return way dB
Test point
Pwr. supply V~/W
Dimensions / Weight mm/kg
KDG class
Type
5700 2410 (PU:10)5700 2597 (PU:1)
ampl. with level attn.
5-65 / 85-1006
25 / 35
0 ... 20
0 / 7
5 / 6
100
medium load
0 ... 20
0/3/6/9
Input+Output
230/8
150x90x50/ 0.85
B (3.2) + C (3.2)
5700 2411 (PU:10)5700 2598 (PU:1)
ampl. with level attn.
5-65 / 85-1006
29 / 39
0 ... 20
0 / 7
5 / 6
101
medium load
0 ... 20
0/3/6/9
Input+Output
185-265/6
150x90x50/ 0.85
C (4.2)
5700 2409 (PU:10)5700 2596 (PU:1)
ampl. with level attn.
5-65 / 85-1006
25 / 33
0 ... 20
0 / 7
5 / 6
98
medium load
0 ... 20
-
-
230/8
150x90x50/ 0.85
B (3.1)
5700 2408 (PU:10)5700 2595 (PU:1)
ampl. with level attn.
5-65 / 85-1006
18 / 20
0 ... 20
0 / 7
5 / 6
100
medium load
0 ... 20
-
-
230/7,5
150x90x50/ 0.85
B (1.1)
BKE 22PS-KDG BKE 33PS-KDG BKE 36PS-KDG BKE 39PS-KDG
12
Upst
ream
Dow
nstre
am
BKE 41 P
HOUSE AMPLIFIER PROFI-LINE BKE-P
HJ Return way on board HJ Frequency range up to 1006 MHz HJ Extreme low distortion and noise on return way HJ JXP PAD‘s for level and slope adjustmentHJ Die-cast housing IP 20 for low operating temperature, long lifetime
and reliabilityHJ Very compact shape HJ LED indicator for operation statusHJ F-connectorsHJ UPC - Unitymedia KBW certified
Article-No.
Frequency range MHz
Gain dB
Noise dB
Linearity dB
Attenuation (PAD‘s) dB
Attenuation Interstage switchable dB
Slope dB
Interstage slope switchable dB
Outputlevel max.CSO / CTB > 60 dB, 42 CH flat dBµV95K n. UM ch grid 7dB slope dBµV
Frequency range MHz
Gain with fix 3dB slope dB
Noise dB
Attenuation (PAD‘s) dB
64 QAM, 3 carriers,120 dBµV, UM
Power supply V~
Power consumption W
Test point F -20 dB
Burst protection kV
Connector
Dimensions mm
Weight kg
Type5700 2303
PU: 10
85 - 1006
33 ± 1
5
± 0.5
0 ,1,2... 20
–
0 ,1,2... 20
0/7
9899
5 - 65
23 ± 1
5
0 ,1,2... 20
< 1*10-8
230
8.0
output
2.0
F-connector
188 x 85 x 50
0.8
5700 2008
PU: 1
85 - 1006
20 ± 1
5
± 0.5
–
–
–
102104
5 - 65
20 ± 1
5
–
< 1*10-8
185-265
4.5
Input + output
4.5
F-connector
188 x 85 x 50
0.7
5700 2304
PU: 10
85 - 1006
35 ± 1
5
± 0.5
0 ,1,2... 20
–
0 ,1,2... 20
0/7
100 101
5 - 65
25 ± 1
5
0 ,1,2... 20
< 1*10-8
230
8.0
output
2.0
F-connector
188 x 85 x 50
0.8
BKE 33 P BKE 2220-1 BKE 36 P5700 2306
PU: 10
85 - 1006
41 ± 1
5
± 0,7
0 ,1,2... 20
0/6
0 ,1,2... 20
0/7
106108
5 - 65
32 ± 1
5
0 ,1,2... 20
< 1*10-8
185-265
7.0
Input + output
2.0
F-connector
188 x 85 x 50
0.7
5700 2305
PU: 10
85 - 1006
39 ± 1
5
± 0.5
0 ,1,2... 20
0/6
0 ,1,2... 20
0/7
103105
5 - 65
29 ± 1
5
0 ,1,2... 20
< 1*10-8
185-265
5.0
Input + output
2.0
F-connector
188 x 85 x 50
0.7
BKE 41 PBKE 39 P
13
HFC-
COM
PON
ENTS
HOUSE AMPLIFIER PROFI-LINE BKD-SF
HJ Prepared for FOSTRA-F network monitoringHJ 1 GHz bandwidth, modular return way (page 33) HJ Unique Step Spin technology - allows readable values and fast
adjustmentHJ No accessories needed for operation HJ Low noise by GaAs-FET IC‘s HJ Cable equivalent 0 / 5 / 10 dB on input selectableHJ Modular power supply allows an easy in field replacement or up-
grade - less service interruption, no new adjustment neededHJ With FOSTRA-F: IDS 0 / 6 / 45 dB on return switchable (option)
BKD xx SF: HJ Push-Pull amplifer with high output level (BKD 40SF)HJ MultiGainTech: gain switchableHJ Kabel Deutschland certified
Article-No.
Frequency range
Plug-in slot
Gain dB
Noise1 dB
Linearity1 dB
Slope Step Spin
Level Step Spin
Interstage slope
Interstage attenuation
Output level1 max.1
CSO / CTB > 60 dB, 42 Ch flat dBµV 95 K Unity Media grid, 7dB Slope dBµV
Power supply V~
Power consumption W
Test point F -20 dB
Burst protection kV
Connector
Dimensions / Weight mm/kg
5700 2160
40 - 1006
1
25/31 ± 1switchable
7
± 0.7
0/7 dB switchable
0/6 dB switchable
99 / 100102
230
3.6
Input + output
2.0
F-connector
170x85x50/ 0.7
BKD 30 SF
5700 1867
40 - 1006
1
29/35 ± 1switchable
7
± 0.7
0/7 dB switchable
0/6 dB switchable
105 / 105106
185-265
5.1
Input + output
2.0
F-connector
188x85x50/ 0.7
5700 1868
40 - 1006
1
34/40 ± 1 switchable
7
± 0.7
0/7 dB switchable
0/6 dB switchable
109 / 109110
185-265
8.3
Input + output
2.0
F-connector
188x85x50/ 0.7
BKD 35 SF BKD 40 SF
step attenuator slope 0...10 dB + 10dB; 2 dB step wide
step attenuator 0...10 dB + 5dB; 2 dB step wide
1 without returnway module
Type
BKD 40 SF
14
Upst
ream
Dow
nstre
am
HOUSE AMPLIFIER LHE-P
HJ 1 GHz bandwidth HJ MultiGainTech 40/32 dB HJ JXP PADs for level and slope adjustment HJ Reliable adjustment of all values over life timeHJ Cable simulator on input HJ Extreme low distortion and noise on return wayHJ Input/Output horizontal or vertical assemblyHJ Excellent linearity up to 1 GHzHJ Alu die-cast housing IP 65, strand mount possibleHJ UPC - Unitymedia KBW certified
Article-No.Frequency range MHz
Gain dB
Linearity dB
Cable simulation dB
Attenuation dB
Slope dB 0-point loss dB
Interstage attenuation dB
Interstage-slope dB
Return loss Input/Output dB
Return loss Input/Output dB
Output level 41 Ch, CENELEC, CSO/CTB > 60 dB 7dB Slope dBµV
Output level 95 K, UM-ch grid, 7 dB slope dBµV
Operation level 95 K, UM-ch grid, 7 dB slope dBµV
Frequency range MHz
Gain dB
Linearity dB
Attenuation input dB
Slope dB
Attenuation output dB
Return loss Input/Output dB
Noise
Outputlevel-BER at 120 dBµV
64 QAM, 3 carrier,120 dBµV, UM dBµV
Pwr. supply V~
Pwr. consumption W
Dimensions / weight mm/kg
Connector
Type LHE 41 P
5700 193685-1006 (Diplexer on board)
32/40, switchable
± 0.5
0,1,2,3…10, plug able JXP-PADs
0,1,2,3…20, plug able JXP PADs
0,1,2,3…20, plug able JXP-PADs± 0.5, at 1 GHz
0,1,2,3…10 with PADs
0/7/10 with PADs
18 -1.5 dB, Octave, Reference 47 MHz
< 6, Tu ≤ 40° C
113/112, without K2
110, CTB/CSO > 60 dB; BER < 1*10-9
108
5-65
22/32, switchable
± 0.8
0,1,2,3…15, pluggable JXP-PADs
0,1,2,3…12, pluggable JXP-PADs
0,1,2,3…20, pluggable JXP-PADs
18, 5-65 MHz
5, Tu ≤ 40° C
< 1*10-8
185 - 265
14.5 max. incl. active return way
225x180x95/ 1.8
PG 11/F-connector included
16
LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHE
HJ 1 GHz bandwidth HJ Interrupt free electronic adjustment, basic settings without
additional accessoriesHJ 7-Segment display, simply to adjust by keypad HJ MultiGainTech 41/30 dB HJ AGC module available HJ High output level by GaAs-FETHJ 2 outputs, Input/Output horizontal or vertical assemblyHJ LED indicator for operation status HJ Alu die-cast housing IP 65, strand mount possible
Upst
ream
Dow
nstre
am
Article-No.Frequency range MHz
Gain dB
Linearity dB
Slope dB 0-point loss dB
Interstage slope dB
Attenuation dB
Interstage attn, slot. UPP1/UPP2 dB
Interstage slope, slot UPP1/UPP2 dB
Testpoint input dB
Testpoint output dB
Return loss In/Out dB
Noise dB
Outputlevel 42 Ch, CENELEC, flat dBµV
Outputlevel 42 Ch, CENELEC, 7dB slope dBµV
Frequency range MHz
Gain passive /active dB
Linearity dB
Slope (Output) dB
Attenuation (Output) dB
Input slot UPP3 dB
Interstage attenuation dB
Testpoint 5 - 65 MHz dB
Noise dB
Outputlevel 2nd order, -60 dB dBµV
Outputlevel 3rd order, -60 dB dBµV
Outputlevel-BER at 120 dBµV medium load 3 carrier 16 QAM BER
Power supply V~
Power consumption W
Dimensions / Weight mm/kg
Connector
Type LHE 40-1 LHE 40-1R
85-1006 (Diplexer on board)
40, to 30 dB switchable
± 0,5
0 ... 20, 1 dB steps adjustment, electronical ± 0,5, at 1 GHz
0/6, switchable
0 ... 20, 1 dB steps adjustment, electronical
0,1,2, ... 20 JXP-Pads for 1 dB step adjustment
3,6,9,12 with EZL/EZP adjustment
-20 ± 1.5 dB, F-connector, internal
-20 ± 0.75 dB, F-connector, internal
-20 ± 1.5 dB/Octave, min. -12 dB at 1 GHz
6,5 Tu ≤ 40° C
110, CTB/CSO > 60 dB
113, CTB/CSO > 60 dB
5-65 (Diplexer on board)
-4 / 24 / 32
± 0.5
0 ... 20, 1 dB steps adjustment, electronical
0 ... 20, 1 dB steps adjustment, electronical
0,1,2, ... 20 JXP-Pads in 1 dB steps adjustable
0 / 8, switchable by jumper
-20 ± 0.75 dB, F-connector, 2x internal
6, Tu ≤ 40° C
108, DIN 45004A1
116, DIN 45004B
1*10-6 (KDG 1TS140)
185 - 265 local pwr. or. 28 - 65 V remote pwr. 10 A feed through
14.5 max. active return way
225 x 180 x 95/ 1.8
PG 11 thread (connectors excluded)
5700 1626 (local pwr.) 5700 1627 (remote pwr.)
For the necessary plu-in modules please refer to the table on page 10.
18
LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHD
HJ ,Prepared for network management systemHJ 1 GHz Bandwidth, modulare return way by diplexerHJ Interrupt free electronic adjustment, get it operable without
additional accessoriesHJ 7-segment display, simply to adjust by keypad HJ Extended up stream bandwidth to 105 MHz to configure by diplexer HJ AGC module available HJ 2 outputs, IN/OUT connectors in vertical or horizontal positionHJ Compact alu die-cast housing acc. IP 65, strand mountableHJ With FOSTRA-F: IDS 0 / 6 / 45 dB switchable at the return HJ FOSTRA-D (DOCSIS transponder) LHD 41 ED / R-ED Version
HJ FOSTRA-F FSK-RX HJ FOSTRA-D DOCSIS-Transponder
Upst
ream
Dow
nstre
am
Article-No.
Frequency range MHz
Gain dB
Linearity dB
Slope dB 0-point loss dB
Interstage slope dB
Attenuation dB
Interstage attn., slot UPP1 dB
Cablesimulation dB
Testpoint input dB
Testpoint output dB
Return loss In/Out dB
Noise dB
Outputlevel 42 Ch, CENELEC, flat dBµV
Outputlevel 42 Ch, CENELEC, 7dB slope dBµV
Frequency range MHz
Gain passive / active dB
Linearity dB
Slope (Output) dB
Attenuator (Output) dB
Input slot UPP2 dB
Ingress Detection Switch dB
Slope frequency point dB
Noise dB NPR/CNIR @ 35MHz, 65MHz noise bw
Output-BER at 120 dBµV full load 6 carrier 16 QAM BER
Power supply V~
Power consumption W
Dimensions / Weight mm/kg
Connector
Type LHD 41 LHD 41 R
5-1006 (return way ampl. 105 MHz on board, modular diplexer)
40, to 30 dB ± 1 switchable
± 0.5
0 ... 25, 1 dB step adjustment, electronical ± 0.5, at 1 GHz at 862 MHz switchable
0...15, electronical adjustment
0 ... 20, 1 dB step adjustment, electronical
for JXP-PAD‘s useable
0 / 5 / 10 by jumper switchable
-20 ± 1.5 dB, F-connector, internal
-20 ± 0.75 dB, F-connector, internal
18dB @ 40MHz -1.5 dB/Octave
typ. 6.5 Tu ≤ 40° C
110, CTB/CSO > 60 dB
113, CTB/CSO > 60 dB
5-105 (configuration with modular diplexer)
-4.5 / 26
± 0.5
0 ... 10, 1 dB step adjustment, electronical
0 ... 20, 1 dB step adjustment, electronical
for additional low pass filter LPF 5-85 or JXP-PAD‘s
0 / 6 / 45, switchable by FOSTRA
65/85 switchable by jumper
6.5 Tu ≤ 40° C
50dB @ -46dBmV/Hz input level, 24dB Dynamic range
1*10-6 (acc. KDG 1TS140)
16.3 active return way
225 x 180 x 95/ 1.8
PG 11 thread (connectors excluded)
5700 2098 LHD 41 R (remote pwr.)5700 2823 LHD 41-1 R (Line-OUT, remote pwr.)5700 2100 LHD 41 R-ED (DOCSIS, remote pwr.)
185 - 265 V local pwr. 28 - 65 V remote pwr.
10 A feed through
5700 2097 LHD 41 (local pwr.) 5700 2822 LHD 41-1 (Line-OUT) 5700 2099 LHD 41 ED (DOCSIS)
20
LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER NVD
FOSTRA-D transponder acc. to EURODOCSIS-Standard 2.0
The following parameters can be monitored and controlled via the trans-ponder:
HJ QoS information such as C/N, BER, MHz, HF-level etc. HJ Return way Ingress-Control-Switch HJ Temperature HJ Identification of the amplifier type and place of installationHJ Other control and monitoring functions
Key benefitsHJ Manageable 1GHz trunk and line extender for modern
HFC-architectures
HJ Flexible transponder solution with DOCSIS-transponder FOSTRA-D or FSK FOSTRA-F microreceiver used to control and monitor with Webbrowser WebGui
HJ Manageable by DELTANET
HJ Solid alu die-cast housing, protection class IP 65
HJ Built in return amplifier, extended bandwidth to 105 MHz configurable via modular diplexer
HJ Ingress-Control-Switch 0 / 6 / 45 dB.
HJ State of the art GaAs-FET-IC pre-stages and GaAs-FET MMIC final stage for excellent linearity, low noise and high output level
HJ All adjustments by electronic keypad and LED-display
HJ Electronic Interstage-slope and attenuation
HJ For automatic adjustment of temperature induced level variations an AGC module can be used
HJ Complete equipment and testpoints
Remark: Fittings are not included in delivery.
HJ FOSTRA-D DOCSIS-TransponderHJ FOSTRA-F FSK-RX
FOSTRA-F microreceiver for amplifier Cost-effective monitoring system for amplifier and nodes:
HJ Monitoring function: Ingress Detection Switch 0 / 6 / 45 dBHJ Monitoring status LED indicates the operational modusHJ RX frequency 868.3 MHz HJ Identification of the amplifier type and place of installation
21
HFC-
COM
PON
ENTS
LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER NVD
HJ Controlable line- and distribution amplifier for interactive HFC-networks
HJ Two independent, active high power outputsHJ Flexible transponder solution with DOCSIS-transponder FOSTRA-D or FSK FOSTRA-F microreceiverHJ Electronic level and slope adjustmentHJ Flexible and future proof returnway with bandwidth extension to
105 MHz, configurable by modular diplexerHJ Ingress-Control-Switch 0 / 6 / 45 dB on return way HJ Low noise by GaAs-FET-IC pre-amplifier stagesHJ High output level using Power-Doubler GaAs-FET technologyHJ AGC ± 3.5 dB - module plugable HJ Power pass of 10 A, with overvoltage protection 6 kVHJ Compact alu-die cast housing IP 65
Upst
ream
Dow
nstre
am
Article-No.
Final stage
Frequency range MHz
Gain dB
Noise dB
Linearity dB
Attenuation input dB
Slope 862/1006 MHz dBInterstage slope + attenuation dB
Outputlevel max
CSO / CTB > 60 dB, 42 CH flat dBµV
Return loss dB
Frequency range MHz
Gain dB
Noise dB
Attenuation dB
Slope dB
lngress Detection Switch dB NPR/CNIR @ 35MHz, 65MHz noise bw
BER @ 120 dBµV BER (6 carrier QAM 16; 5,12 Msym/s)
Power supply V~
Power pass A
Hum-isolation dB
Power consumption
Testpoint inputTestpoint output
Burst- / Surge protection kV
Connector
Dimensions / Weight mm/kg
RF-IN/OUT connection
Type NVD 9240 ED
5700 2101
2 x Power Doubler GaAs-FET
5 - 1006
2 x 41 ± 1
typ. 6.5 Tu ≤ 40° C
± 0.7
0 ... 20
0 ... 200 ... 15
2 x 114
5 - 105 (configured by Diplexer)
26 ± 1
7
0 ... 20
0 ... 10
0 / 6 / 45 switchable with FOSTRA
50dB@ -46dBmV/Hz input level
< 1*106
(KDG 1TS140)
28-65
10
> 60
31 W (without transp.)
6 / 6
PG 11 oder 5/8”
250x220x100/ 3.0
2/2
NVD 9240 R-ED
-20 dB (F-connector, internal) bidirectional -20 dB (F-connector, internal) unidirectional
18 dB bei 40 MHz (-1.5 dB/Octave)
5700 2824
2 x Power Doubler GaAs-FET
5 - 1006
2 x 41 ± 1
typ. 6.5 Tu ≤ 40° C
± 0.5
0 ... 20
0 ... 200 ... 15
2 x 114
5 - 105 (configured by diplexer)
26 ± 1
7
0 ... 20
0 ... 10
0 / 6 / 45 switchable with FOSTRA
50dB@ -46dBmV/Hz input level
< 1*106
(KDG 1TS140)
185-265
10
> 60
31 W (without transp.)
6 / 6
PG 11 oder 5/8”
250x220x100/ 3.0
2/2
23
HFC-
COM
PON
ENTS
OVERVIEW AMPLIFIERS 1.2 GHz
House amplifier/Line- and Distributionamplifier
Product family
BK
99 - 109
up to 1218
active, modular 204 MHz
Step-Spin
F-connector
W / –
BKD-G
Application
Output level dBuV
Downstream MHz
Return way
Adjustments
RF-connections
Local / Remote pwr.
LHD-G
Line- and Distribution-
amplifier
114
up to 1218
active, modular 204 MHz
electronical
PG 11 or 5/8”
W /W
GE
Networkmanagement-
compl. distribution amplifier
r
2x115
up to 1218
active, modular 204 MHz
electronical
PG 11 or 5/8”
W /W
NVD-G
BK
105
up to 1218
passive, mod. 204 MHz
JXP-PAD
5/8”
- / W
BKD - G: 1.2 GHz house amplifier, modular return way up to 204 MHz, FOSTRA-F compliant, IDS Ingress Detection Switch, Step-Spin
LHD/NVD: 1.2 GHz Line- and Distribution ampl., modular return way up to 204 MHz, FOSTRA-F / -D compliant, electronical adjustments
GE: 1.2 GHz Gain Extender - pimp up your network on dedicated areas, passive return way, JXP-PAD level adjustment
Glossary
JXP-PADs for adjustments required
Variable level attenuator included, no additional accessories required for level adjustment
Step-Spin adjustment, precise step control, values readable
Electronical adjustment, display, key pad, precise step control, values readable
1.2 GHz technology, DOCSIS 3.1 compliant
Remote management using FOSTRA-TechnologyFOSTRA-F FSK MonitoringFOSTRA-D DOCSIS Monitoring
1.2G
1.2G
24
HJ In the table hereafter the plug-ins for the following products are listed: HJ Amplifier: BKD-G, LHD-G, NVD-G, GE 1212 R
OVERVIEW AMPLIFIER PLUG-IN MODULES
RLK 565-1
HPF 85-1
LPF 5-65
RLK 585-1
HPF 105-1
LPF 5-85
NHP 15-1
RLK 5200
HPF 258-1
LPF 5-204
FOSTRA-F
FOSTRA-D Kit I
VM 302
AM 301-10 A
AM 301-10 B
AGC 303
AGC 403
CK 5-0
Type NVD 9243 GR
Diplexer 65/85 MHz
High pass filter 85 MHz
Low pass filter 65 MHz
Diplexer 85/105 MHz
High pass filter 105 MHz
Low pass filter 85 MHz
Ingress-Filter 15 MHz
Diplexer 204/254 MHz
High pass filter 258 MHz
Low pass filter 204 MHz
FSK-Tr.
DOCSIS-Tr.
2-way splitter
Tap 10dB line out
Tap. 10dB Tap out
AGC-Module
AGC-Module
Jumper-Module 0dB
LHD 43 GR
5700 2732
5700 2297
5700 2295
5700 2733
5700 2298
5700 2296
5700 2116
5700 2776
5700 2819
5700 2820
5700 1981
5700 2329
5700 2092
5700 2093
5700 2117
5700 2091
5700 2493
5700 2308
BKD-GArticle No. DescriptionW
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
GE 1212 R
25
HFC-
COM
PON
ENTS
Dow
nstre
amUp
stre
am
HOUSE AMPLIFIER PROFI-LINE BKD-G
HJ 1.2 GHz DS-bandwidth, modular return way up to 204 MHzHJ FOSTRA-F network monitoring preparedHJ Unique Step Spin technology - allows readable values and fast
adjustmentHJ No accessories necessary for operationHJ DOCSIS 3.1 compliant HJ Modular power supply allows an easy in field replacement or up grade - less service interruption, no new adjustment neededHJ Mit FOSTRA-F: IDS 0 / 6 / 45 dB on return switchable
BKD xx G: HJ Push-Pull amplifer with high output levelHJ Switchable De-emphasis
BKD 22 G BKD 38 G
* to configure by RLK diplexer
Type BKD 30 G
5700 2827
40 - 1218*
2
32/38 ± 1
± 0.8
6.5
0/5/10
0/6 dB switchable
0/6 dB switchable
109107
5-65/85/204*
28
± 0.5
0/6
0/10
0/6/45
< 1.0E-09
185-265
11.1
input + output
2.0
F-connector
188x85x50/ 0.7
5700 2826
40 - 1218*
2
24/30 ± 1
± 0.7
6.5
0/5/10
0/6 dB switchable
0/6 dB switchable
109107
5-65/85/204*
25
± 0.5
0/6
0/10
0/6/45
< 1.0E-09
185-265
10.4
input + output
2.0
F-connector
188x85x50/ 0.7
5700 2825
40 - 1218*
2
22 ± 1
± 0.7
6.5
0/5/10
0/6 dB switchable
106102
5-65/85/204*
21
± 0.5
0/6
0/10
0/6/45
< 1.0E-09
185-265
10.4
input + output
2.0
F-connector
188x85x50/ 0.7
step attenuator 0...10 dB + 10dB; 2 dB steps
step attenuator 0...10 dB + 5dB; 2 dB steps
1.2G
@ -8dBµV/Hz input level dynamic range = 24dB
step attenuator 0...10 dB ; 2 dB steps
step attenuator 0...10 dB ; 2 dB steps
Article-No.
Frequency range DS MHz
Slot for return way diplexer
Gain dB
Linearity dB
Noise dB
De-emphasis input dB
Slope Step Spin
Attenuation Step Spin
Interstage slope
Interstage attenuation
Outputlevel max.1
CSO / CTB > 60 dB, 42 Ch flat dBµV
110 Ch 256 QAM,flat, BER< 1.0E-09 dBµV
Frequency range US MHz
Gain dB
Linearity dB
Interstage slope dB
Interstage attenuation dB
Slope output dB
Attenuation output dB
Ingress Detection Switch dB
50dB NPR @ 35 MHz/65 MHz noise bw
BER @ 107 dBµV, 24 carrier QAM 256
Power supply V~
Power consumption W
Test point F -20 dB
Burst protection kV
Connector
Dimensions / Weight mm/kg
27
HFC-
COM
PON
ENTS
LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHD-G
HJ 1.2 GHz DS-bandwidth, modular return way up to 204 MHzHJ Prepared for network monitoring FOSTRA-FHJ Interrupt free electronic adjustment, basic settings without
additional accessoriesHJ 7-Segment display, simply to adjust by keypad HJ DOCSIS 3.1 compliantHJ AGC/ALSC module available HJ With FOSTRA-F: IDS 0 / 6 / 45 dB switchable at the return HJ 2 outputs, IN/OUT connectors in vertical or horizontal position HJ 10 A remote current feed through, surge protection 6kVHJ Compact alu die-cast housing acc. IP 65, strand mountable HJ FOSTRA-F FSK-RX
Upst
ream
Dow
nstre
am
Article-No.
Frequency range MHz
Gain dB
Linearity dB
Slope dB 0-point loss dB
Interstage slope dB
Attenuation dB
Interstage attn., slot UPP1 dB
Cablesimulation dB
Testpoint input dB
Testpoint output dB
Return loss In/Out dB
Noise dB
Output level 42 Ch, CENELEC, flat dBµV
110 Ch 256 QAM, 9 dB Slope
Frequency range MHz
Gain passive / active dB
Linearity dB
Slope (Output) dB
Attenuator (Output) dB
Input slot UPP2 dB
Ingress Detection Switch dB
Slope frequency point dB
Noise dB
50dB NPR @ 35 MHz/65 MHz noise bw
BER @ 107 dBµV with 24 carrier QAM 256
Power supply V~
Power consumption W
Dimensions / Weight mm/kg
Connector
Type LHD 43 G LHD 43 GR
LHD 43G 5700 2810 (local pwr.)
LHD 43-1G 5700 2829 (Line-OUT local pwr.)
LHD 43GR 5700 2811 (remote pwr.)
LHD 43-1GR 5700 2830 (Line-OUT rem. pwr.)
28 - 65 V remote pwr. 10 A feed through185 - 265 V local pwr..
40 - 1218 (return way ampl. 204 MHz on board, diplexer modular)
43, to 30 dB ± 1 switchable
± 0.5
0 ... 25, 1 dB step adjustment, electronical ± 0.5 at 1218 MHz, switchable to 1006 MHz
0...15, electronical adjustment
0 ... 20, 1 dB step adjustment, electronical
for JXP-PAD‘s
for JXP-PAD‘s
-20 ± 1.5 dB, F-connector, internal
-20 ± 0.75 dB, F-connector, internal
20dB @ 40MHz -1.5 dB/Octave
typ. 6.5 Tu ≤ 40° C
114, CTB/CSO > 60 dB
109 dBµV / BER < 1.0E-09
5-65/85/204 (configuration with modular diplexer)
-5 / 28
± 0.5
0 ... 10, 1 dB step adjustment, electronical
0 ... 20, 1 dB step adjustment, electronical
for additional low pass filter LPF x-xx or JXP-PAD‘s
0 / 6 / 45, switchable with FOSTRA
85/204 switchable by Jumper
6.5 Tu ≤ 40° C@ -6dBµV/Hz input level, 24dB dynamic range
< 1.0E-09
17.0 with active return way
225 x 180 x 95/ 1.8
PG 11 thread (connectors not included)
1.2G
29
HFC-
COM
PON
ENTS
1.2G
LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER EXPERT-LINE NVD 1.2 GHz
FOSTRA-D Transponder acc. to EURODOCSIS-Standard 2.0
The following parameters can be monitored and controlled via the trans-ponder:
HJ QoS information such as C/N, BER, MHz, HF-level etc. HJ Return way Ingress-Control-Switch HJ Temperature HJ Identification of the amplifier type and place of installationHJ Other control and monitoring functions
Key benefitsHJ Manageable 1.2 GHz trunk and line extender for modern
HFC-architectures
HJ Flexible transponder solution with DOCSIS-transponder FOSTRA-D or FSK FOSTRA-F microreceiver used to control and monitor with Webbrowser WebGui
HJ Manageable by DELTANET
HJ Solid Alu-die cast housing, protection class IP 65
HJ Built-in return amplifier, extended bandwidth to 204 MHz configurable via modular diplexer
HJ Ingress-Control-Switch 0 / 6 / 45 dB.
HJ State of the art GaAs-FET-IC pre-stages and GaAs-FET MMIC final stage for excellent linearity, low noise and high output level
HJ All adjustments electronically operated by keypad and LED-display
HJ Electronic interstage-slope and attenuation adjustment
HJ For automatic adjustment of temperature induced level variations an AGC/ALSC module can be used
HJ Complete equipment and testpoints
Remark: Fittings are not included in delivery
HJ FOSTRA-D DOCSIS-TransponderHJ FOSTRA-F FSK-RX
FOSTRA-F microreceiver for amplifier Cost-effective monitoring system for amplifier and nodes:
HJ Monitoring function: Ingress Detection Switch 0 / 6 / 45 dBHJ Monitoring status LED indicates the operational modeHJ RX frequency 868.3 MHz HJ Identification of the amplifier type and place of installation
30
1.2G
LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER EXPERT-LINE NVD-G
HJ 1.2 GHz DS-bandwidth, modular return way up to 204 MHzHJ Controlable line- and distribution amplifier
for interactive HFC-networksHJ Two independent, active high power outputsHJ Flexible transponder solution with DOCSIS-transponder FOSTRA-D or FSK FOSTRA-F microreceiverHJ Electronical level and slope adjustmentHJ DOCSIS 3.1 compliant HJ Ingress-Control-Switch 0 / 6 / 45 dB on return wayHJ Low noise by GaAs-FET-IC pre-amplifier stagesHJ High output level using Power-Doubler GaAs-FET technologyHJ AGC module available HJ Power pass of 10 A, with overvoltage protection 6 kVHJ Compact die-cast housing IP 65
Upst
ream
Dow
nstre
am
Article-No.
Final stage
Frequency range MHz
Gain dB
Noise dB
Linearity dB
Attenuation input dB
Slope 1006/1218 MHz dBInterstage Slope + Attnuation . dBCSO / CTB > 60 dB, 42 Ch flat dBµV110 Ch 256 QAM, 9 dB Slope dBµV
Return loss dB
Frequency range MHz
Gain dB
Noise dB
Attenuation dB
Slope dB
Ingress Detection Switch
50dB NPR@35 MHz/65 MHz noise bw
BER @ 107 dBµV with 24 carrier
QAM 256
Power supply V~
Power pass A
Hum-isolation dB
Power consumption
Testpoint inputTestpoint output
Burst- / Surge protection kV
Connector
Dimensions / Weight mm/kg
RF-IN/OUT connection
Type NVD 9243 G-ED
5700 2812
2 x Power Doubler GaAs-FET
40 - 1218
2 x 43 ± 1
typ. 7,0 Tu ≤ 40° C
± 0.5
0 ... 20
0 ... 200 ... 152 x 115
110 dBµV / BER < 1.0E-09
5 - 65/85/204 (with diplexer)
28 ± 1
7
0 ... 20
0 ... 10
0 / 6 / 45 switchable FOSTRA
< 1.0E-09
28 - 65 V remote pwr.
10
> 60
35 W (without transp.)
6 / 6
250x220x100/ 3,0
2/2 PG 11 thread
NVD 9243 GR-ED
5700 2831
2 x Power Doubler GaAs-FET
40 - 1218
2 x 43 ± 1
typ. 7,0 Tu ≤ 40° C
± 0.5
0 ... 20
0 ... 200 ... 152 x 115
110 dBµV / BER < 1.0E-09
5 - 65/85/204 (with diplexer)
28 ± 1
7
0 ... 20
0 ... 10
0 / 6 / 45 switchable FOSTRA
< 1.0E-09
185 - 265 V local pwr.
10
> 60
35 W (without transp.)
6 / 6
250x220x100/ 3,0
2/2 PG 11 thread
-20 dB (F-Buchse, intern) bidirectional -20 dB (F-Buchse, intern) unidirectional
18 dB bei 40 MHz (-1.5 dB/Octave)
@ -6dBµV/Hz input level dynamic range = 24dB
PG 11 (connectors not incl.)
32
1.2G
GE 1212 R
GAIN EXTENDER 1.2GHz
HJ Applicable for simple network extension to 1.2 GHz HJ 1.2 GHz bandwidth HJ Passive return way 204 MHz to configure by diplexerHJ Low gain, low noise by GaAs-FET IC‘s HJ JXP-PAD‘s for adjustments HJ Push-Pull stage with high output levelHJ Remote power with 10A feed throughHJ DOCSIS 3.1 compliant HJ Compact die-cast housing IP 65, 6 kV surge protected
Article-No.
Frequency range
Slot for return way diplexer RLK
Gain dB
Return way loss dB
Noise dB
Linearity dB
Slope (JXP-PAD)
Attenuation (JXP-PAD
0dB slope point MHz
Output level max.CSO / CTB > 60 dB, 42 Ch flat dBµV 110 Ch 256 QAM, BER < 1.0E-09 dBµV
Power supply V~
Power consumption W
Power pass A
Burst+Surge protection kV
Connector
Dimensions / Weight mm/kg
5700 2488
40 - 1218
2
12 ± 1
3
5,5 (< 1GHz) 6,5 (<1.2GHz)
± 0.5
with JXP-PAD 0...20 dB
with JXP-PAD 0...20 dB
1218
10598
30...65
3.5
10
6
2 x 5/8“- Connector
155x120x100/ 1.1
GE 1212 RType
33
HFC-
COM
PON
ENTS
1.2G
OVERVIEW AMPLIFIER PLUG-IN MODULES
AGC 403HJ AGC module for automatic gain and slope controlHJ 2-tone-controlled module HJ Upper and lower QAM channels will be used as reference pilotHJ Stable control over a wide temperatur rangeHJ LED-indicator for level and slope adjustment HJ Precise adjustment by potentiometer
Article-No.
Description
Frequency range MHz
Linearity dB
Through loss dB
Gain control dB
Slope control
Pilottone 1 MHz
Pilottone 2 MHz
Temperature control range
NVD 9xxx
LHD 4x
Dimension / Weight mm/kg
Type 5700 2091
AGC Module
5-1218
± 0.2
2
± 3dB (sum control)
-30...+60
W
W
29 x 34 x 10 / 0.05
AGC 303 5700 2493
AGC Module
5-1218
± 0.2
2
± 3dB
± 2dB
125 ...160
542...630
-30...+60
W
W
29 x 37 x 10 / 0.05
AGC 403
AGC 303HJ AGC sum level module for automatic gain control HJ Sum channel load will be used as reference pilotHJ Stable control over a wide temperatur rangeHJ Precise adjustment by potentiometer
Article-No.
Description
Frequency range MHz
Loss dB
Type
NVD 9xxx
LHD 4x
Type 5700 2092
2-way splitter
5-1218
4.5
W
W
VM 302
5700 2093
1-way tap
5-1218
1.3 / 10.0
Tap out
W
W
AM 301-10A
5700 2117
1-way tap
5-1218
1.3 / 10.0
Line out
W
W
AM 301-10B
AM/VM-Plug-in modulesHJ Taps- and splitter modules for LHD/NVD
For detailed application of VM/AM modules please refer to the respective block diagram (S.28/31)
34
RETURNWAY PLUG-IN MODULES FOR HOUSE AMPLIFIER BKD-SF
HJ For BKD-SF amplifier HJ IDS - Ingress Detection SwitchHJ Step Spin adjustment, readable valuesHJ High output levelHJ Excellent linearity
Type
Article-No.
Return way MHz
Gain dB
Attenuation dB
Slope dB
Linearity dB
Noise dB
Ingress Detection Switch dB
Output level KBW medium load dBµV 4 carrier QAM 64 BER
DS frequency range MHz
Loss dB
Power consumption W
5700 2432
5-65
23
0,2,4...16 dB
0/2/4/6
± 0.5
4.5
0 / 6 / 45 115
< 1*10-8
85-1006
- 1.0
1.6
5700 1956
5-65
32
0,2,4...16 dB
0/3/6/9
± 0.5
4.5
0 / 6 / 45 115
< 1*10-8
85-1006
- 1.0
1.7
RV 65-22 EF RV 65-32 EF
RETURNWAY PLUG-IN MODULES FOR LINE-/ DISTRIBUTION-AMPLIFIERS
HJ Diplexer-Modules RLKHJ For 1 GHz amplifier LHD 41 and NVD 9240HJ Return loss >20 dB at 47 MHz, -1.5 dB per octaveHJ Metal cover for solid protection and high screening immunityHJ Remark: multiple pieces per amplifier needed
Type
5700 2095
LHD 41 / NVD 9240
5-65
85-1006
0.5
> 50 per diplexer
30 x 35 x 8 / 0.05
RLK 565
5700 2096
LHD 41 / NVD 9240
5-85
105-1006
0.5
> 50 per diplexer
30 x 35 x 8 / 0.05
RLK 585
Article-No.
Application
Frequency range Upstream MHz
Frequency range Downstream MHz
Through loss dB
Isolation Up-/Downstream dB
Dim. / Weight mm/kg
35
HFC-
COM
PON
ENTS
RETURNWAY PLUG-IN MODULES FOR LINE-/ DISTRIBUTION-AMPLIFIERS
HJ Diplexer-Module RLKHJ For 1.2 GHz amplifier BKD-G/LHD-G/NVD-GHJ Return loss >20 dB at 47 MHz, -1.5 dB per octaveHJ Metal cover for solid protection and high screening immunityHJ Remark: multiple pieces per amplifier needed
Type
5700 2732
BKD-G/LHD 43G / NVD 9243G
5-65
85-1218
0.5
> 50 per diplexer
30 x 26 x 8 / 0.05
RLK 565-15700 2776
BKD-G/LHD 43G / NVD 9243G
5-204
258-1218
0.5
> 50 per diplexer
30 x 26 x 8 / 0.05
RLK 585-1Article-No.
Application
Frequency range Upstream MHz
Frequency range Downstream MHz
Through loss dB
Isolation Up-/Downstream dB
Dimens. / Weight mm/kg
1.2G
5700 2733
BKD-G/LHD 43G / NVD 9243G
5-85
105-1218
0.5
> 50 per diplexer
30 x 26 x 8 / 0.05
RLK 5200
High pass / low pass-filter plug-in modulesHJ For LHD/NVD to increase the isolation between US/DS HJ For pairwise use LPF/HPF depends on RLK diplexer configurationHJ E.g. 2 x RLK 565-1 requires 1 x LPF 5-65 + 1 x HPF 85-1HJ Style JXP 1“, 3-PIN
Type LPF 5-65
5700 2295
LHD / NVD
5-65
LP stopp
0.4
> 30
8 x 28 x 4 /0.01
Article-No.
Application
Frequency range Upstream MHz
Frequency range Downstream MHz
Through loss dB
Stopp band isolation dB
Dimens. / Weight mm/kg
LPF 5-85 LPF 5-204 HPF 85-1 HPF 105-1 HPF 258-1
5700 2296
LHD / NVD
5-85
LP stopp
0.4
> 30
8 x 28 x 4 /0.01
5700 2820
LHD / NVD
5-204
LP stopp
0.5
> 30
8 x 28 x 4 /0.01
5700 2297
LHD / NVD
HP stopp
85-1218
0.5
> 30
8 x 28 x 4 /0.01
5700 2298
LHD / NVD
HP stopp
105-1218
0.5
> 30
8 x 28 x 4 /0.01
5700 2819
LHD / NVD
HP stopp
285-1218
0.5
> 30
8 x 28 x 4 /0.01
Type NHP 12-1
5700 2815
LHD / NVD
12-204
0.1-10
0.4
> 40
8 x 28 x 4 /0.01
Article-No.
Application
Frequency range Upstream MHz
Stopp band MHz
Through loss dB
Stopp band isolation dB
Dimens. / Weight mm/kg
NHP 15-1 NHP 18-1
5700 2116
LHD / NVD
15-204
0.1-13
0.4
> 40
8 x 28 x 4 /0.01
5700 2814
LHD / NVD
18-204
0.1-15
0.4
> 40
8 x 28 x 4 /0.01
Ingress high pass filter - plug-in moduleHJ For LHD/NVD to prevent Ingress distortion jamming on return wayHJ Style JXP 1“, 3-PIN
36
Article-No.
Loss dB
Type
1016 1523
0
PAD 0
1016 1524
1
PAD 1
1016 1525
2
PAD 2
1016 1526
3
PAD 3
1016 1527
4
PAD 4
1016 1528
5
PAD 5
1016 1529
6
PAD 6
Article-No.
Loss dB
Type
1016 1530
7
PAD 7
1016 1531
8
PAD 8
1016 1532
9
PAD 9
1016 1533
10
PAD 10
1016 1534
11
PAD 11
1016 1535
12
PAD 12
1016 1536
13
PAD 13
Article-No.
Loss dB
Type
1016 1537
14
PAD 14
1016 1538
15
PAD 15
1016 1539
16
PAD 16
1016 1540
17
PAD 17
1016 1541
18
PAD 18
1016 1542
19
PAD 19
1016 1543
20
PAD 20
Length 25.4 mm (1”)
ATTENUATION JXP-PADS
HJ Fix attenuation-PAD’sHJ 1 dB step values for gain and slope adjustmentHJ Plastic cover for solid protectionHJ Length 1” available
PAD SETBOX
TypeArticle-No.
Description
5700 2032
Setbox equipped with 630 pcs PADs
30 x 0, 1, 2 ... 20 dB PADs 1“
pre equipped unequipped
5700 2084
empty setbox with 21 separations
37
HFC-
COM
PON
ENTS
Article-No.
Description
Type
1016 1204
PG 11 - reduction ringPG 11 / 5/8”
PG 11m-5/8f
1016 1205PG 11
Blind cap
PG 11 PC
Article-No.
Description
Connector Pin length
Type
5700 1141
PG 11 - Adapter
PG 11 / 3.5/12 female
47 mm
PG11m-3,5/12f
5700 1291
PG 11 - Adapter
PG 11 / 3.5/12 female
17 mm
PG11m 3,5/12f
5700 1082
PG 11 - Adapter
PG 11 / F-female
47 mm
PG11m-Ff
1016 1203
PG 11 - Adapter
PG 11 / IEC-female
17 mm
PG11m-IECf
FITTINGS PG 11
38
~~TP 65 MHz
HP 5 MHz3 kV
Deemphasis3 dB
Deemphasis6 dB
OUT (NE 4)TP IN/OUTIN (NE 3)
S 3 S 4
S 5
S 6
S 2S 1
75 Ohm
ÜSA / 3 kV~~
Article-No.
Frequency range MHz
Isolation 5-65 MHz dB
Through loss dB
Linearity dB
Isolation In/Out at S1 at 75 Ω dB
Deemphase 470-1006 MHz dB
Surge- and Burst protection kV
Test point
Dimensions B x H x T mm
Weight kg
Network termination NE3
Return loss dB
Type
5700 1434
0.8
± 0.5
50
0 / 3 / 6 switchable
3
1 F-connector (switchable between in- and output)
100 x 90 x 45
0.3
75 Ohm (switchable)
-20 dB at 40 MHz / -1.5 dB/octave
HÜP 862 D
CATV-NETWORK TERMINATION POINT PROFI-LINE
HJ For broadband network termination between level 3 (street installa-tion) and level 4 (house installation)
HJ Alu die-cast housing, IP 54HJ Frequency range 5 to 1006 MHzHJ Switchable return way cut off filter built-inHJ Galvanic isolated inner conductorHJ Deemphase slope adjustableHJ Surge- and Burst protectionHJ Test point, between IN/OUT switchableHJ Plastic cover for solid protectionHJ Secured against unauthorized opening
5-1006without return way blocking
–
85-1006with return way blocking
40
39
HFC-
COM
PON
ENTS
Upst
ream
Dow
nstre
am
TV
TV
TV
LaptopCM
Laptop
CM
Laptop
CM
Receiver
TV
DOCSIS-STB
TVLaptop CMTV
HÜP
2-WAY APARTMENT-AMPLIFIER
HJ 2-way apartment-amplifier with active return way HJ Perfect for Multimedia-or DOCSIS-application,
Modem-, TV- or STB-extensionHJ For push on at antenna wall outletsHJ Active 2-way split to connect a cablemodem to one or more
multimedia wall outletsHJ Connection: 2 x F-female connector, 1 x F-male connectorHJ Including power adapter
Article-No.
Input
Outputs
Frequency range MHz
Gain dB
Noise dB
Linearity dB
OutputlevelCSO / CTB > 60 dB, 42 CH flat dBµVMA
2 / IMA
3 > 60 dB, DIN-level dBµV
Frequency range MHzGain dB
Linearity dB
Power supply V~
Power consumption W
Connector
Dimension B x H x T / Weight mm/kg
Type
5700 1631
1
2
85 - 1006
2x10
4.5
± 0.5
98112/113
5 - 652x10
± 0.7
230
0.5
2 x F-female connector, 1 x F-male connector
44 x 48 x 24 / 0.6
ZGV 12-65 A
HJ Perfect to extend multimedia wall outlets in case of to high loss or for
connection of a second cable modem or set top box with integrated
cable modem. Ideal to connect another appartment wall outlet.
Germany and Austria
DCT DELTA GmbH
Bodanrückstraße 1
D-78351 Bodman
Tel. +49 7773 929258
Fax +49 7773 929259
www.dct-delta.de
Schwitzerland
DELTA Swiss AG
Industriezone Schächenwald
CH-6460 Altdorf
Tel. +41 4161 91400
Fax +41 4161 91409
www.delta-swiss.ch
7000
0147
Editi
on 4