Cable Gland
-
Upload
ganesh-tigade -
Category
Documents
-
view
323 -
download
8
Transcript of Cable Gland
2005 Cable Glands Catalogue
Thomas & Betts Nylon Cable Glands are quick & easy to install with a high quality gripping claw/seal arrangement that caters
for a wide range of cable sizes per fi tting. Each gland has no loose parts and requires no disassembly for cable installation.
LOCKNUT WASHER BODY CLAW SEALS NUT
ACRO
SS C
ORNE
RS
CABL
EOV
ERAL
LM
AX
MOU
NTIN
GTH
READ
THREADLENGTH
NG Cable GlandGENERAL PURPOSE NYLON CABLE GLANDS
Thomas & Betts, a global leader in the design, manufacture and marketing of electrical products and
accessories is proud to be appointed exclusive distributor of the Nicote range of metal cable glands.
This new catalogue not only details the full Nicote range, but presents the entire Thomas & Betts
range of cable glands from the general purpose NG Nylon range through to 316 Stainless steel
models designed to deliver superior performance in harsh environments.
Thomas & Betts Australasia is proudly committed to delivering innovative solutions to its valued
customers through experienced sales and service teams in each state and the National Customer
Support Centre. Should you not fi nd what you are looking for in this catalogue or need further
information please contact us on 1300 666 595.
ApplicationsIndoor and outdoor use
StandardsAS1939 - 1990
FunctionProvides seal on cable sheath
Protection ClassIP68, Resistant to salt water, weak alcohol, oil, grease and common solvents
ConstructionBody - UL approved Nylon 66 (Black)Seal - EPDM Rubber
Thread TypeMetric with locknut and IP68 washer
Part Mounting Thread Cable Acceptance Details Number Size Length Overall Diameter Across Pack (mm) (mm) Min. Max. Corners Qty. (mm) (mm) (mm)
152227273341506275
50 50 25 25 25 10 10 2 2
NG-12NG-16NG-20NG-20-2.5TPSNG-25NG-32NG-40 NG-50NG-63
151515151515152020
4 6
8.52.5mm TPS
12.518243040
71014
N/A1825324151
M12 x 1.5 M16 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M63 x 1.5
Product specifi cations may change at any time without notice.
1
Make no mistake, the Nicote range of metal cable glands are your guarantee of safety
in hazardous locations especially where fi re and explosion are an identifi ed risk.
Experience counts for a lot when it comes to safety, and the Nicote range is designed and
manufactured by the original Australian producer of the successful Alco brand of glands. Since
1962, Reliance Worldwide has been perfecting their metal cable gland designs and incorporating
the latest high performance materials. The current Nicote range is quite simply the best available
because they do not compromise on safety – and that’s what counts!
Take a look at just some of the features that make Nicote the fi rst choice:
Highly durable nickel platingNicote glands are coated in a proprietary 2 coat plating process that ensures all metal
components will not degrade and potentially let you down over time.
Comprehensive RangeThe greater the range of cable sizes a gland is designed to cover, the higher the risk of seals
failing. Nicote contains a comprehensive range with smaller cable acceptance increments
that also allows the gland bodies to be smaller and hence easier to use when space is tight.
Full ApprovalsDon’t just take our word for it, independent test bodies have confi rmed that the Nicote gland
range complies with relevant standards including approvals for use in mining.
Neoprene SealsAll Nicote glands use high quality Neoprene seals that retain their tension and are resistant to oil,
chemicals and fl ame making them the best choice for hazardous applications.
IP66/68 ProtectionAll Nicote glands classifi ed for indoor/outdoor use are supplied with IP66/68 gaskets for
installation on the mounting thread and neoprene seals on the cable sheath. This level
of protection means that the glands are protected from the ingress of dust and water.
Anything less is unacceptable and compromises safety.
O’Ring SealsAll Nicote glands designed for SWA cable and classifi ed for indoor/outdoor use, feature o’ring
seals between the body and sleeve to ensure that water cannot progress along the thread
and compromise the seal. Just another safety feature.
Easy to useThe ability to easily produce a tight seal and correct earth everytime is of primary importance.
All Nicote glands are designed to be easy to use and to ensure that the installer can see that
the correct fi tting instructions have been followed. For example, all SWA fl ameproof glands
feature a loose clamping cone so that the installer can see that the armour is fully secured.
Technical backingThe Nicote range enjoys the backing of both Thomas & Betts and Reliance Worldwide,
both world reknown manufacturers of quality electrical accessories.
When safety matters, there is only one choice.
Introduction
2
MOU
NTIN
G TH
READ
ACRO
SS C
ORNE
RS
CABL
E OV
ERAL
L
MAX
BODY
IP66/68 GASKET NEOPRENE SEAL
SKID WASHER
NUT
PROTRUSIONTHREADLENGTH
UN12AUN16AUN20AUN20BUN25AUN32AUN40A UN40BUN50A UN50B UN63AUN63B
101010101010161616161919
1.0 1.0 6.010.615.020.025.030.035.040.045.050.0
6.06.010.615.020.025.030.035.040.045.050.055.0
18.320.627.530.933.040.751.155.060.967.078.088.0
131314161718212323242532
60403040408866662
1/2” x 26 TPI M16 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5
Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus, or use a locknut to secure body.3. Pass the cable through the gland to the required position and tighten gland nut so that the seal grips fi rmly onto the cable.
Part Mounting Thread Cable Acceptance Details Cable Gland InnerNumber Size Length Overall Diameter Across Carton (mm) (mm) Min. Max. Corners Protrusion Pack (mm) (mm) (mm) (mm) Qty.
UN Cable GlandGENERAL PURPOSE CABLE GLAND FOR CIRCULAR CABLE
Product specifi cations may change at any time without notice.
3
ApplicationsIndoor and Outdoor use in hazardous areas
StandardsAS1939 - 1990
FunctionProvides Seal on Cable Sheath
Protection ClassIngress of waterIP66/68 (30m)
ConstructionNicote Plated Brass Components
ApplicationsIndoor and Outdoor use in hazardous areas
StandardsAS 1828 - 1984 AS1939 - 1990
FunctionProvides Flameproof Seal on Cable Sheath
Protection ClassAus Ex 2420U Ex I/IICMDA 11641Ingress of waterIP66/68 (40m)
ConstructionNicote Plated Brass Components
Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Pass the cable through the gland to the required position and tighten gland nut so that the seal grips fi rmly onto the cable.
PROTRUSION
ACRO
SS C
ORNE
RS
MOU
NTIN
G TH
READ
BODY
CABL
E OV
ERAL
LM
AX
IP66/68 GASKET NEOPRENE SEAL SKID WASHER
NUT
THREADLENGTH
UFPN20AUFPN20BUFPN20CUFPN25AUFPN32AUFPN32BUFPN40AUFPN40BUFPN50AUFPN50BUFPN63AUFPN63BUFPN250AUFPN275AUFPN300AUFPN350AUFPN350BUFPN400AUFPN400B
M20 x 1.5 M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.52.5”BSP2.75”BSP3.0”BSP3.5”BSP3.5”BSP4.0”BSP4.0”BSP
6.29.112.014.518.221.925.630.034.239.144.048.755.562.469.376.183.089.996.6
9.112.014.518.221.925.630.034.239.144.048.755.562.469.376.183.089.996.6103.0
28283136424652557274888898107115129129143143
21182023232525253133343435363648484848
303020161288622222111111
UFPN Cable GlandFLAMEPROOF CABLE GLAND FOR CIRCULAR CABLE
12.712.712.715202021212828282828353538383838
Product specifi cations may change at any time without notice.
Part Mounting Thread Cable Acceptance Details Cable Gland InnerNumber Size Length Overall Diameter Across Carton (mm) (mm) Min. Max. Corners Protrusion Pack (mm) (mm) (mm) (mm) Qty.
4
ApplicationsIndoor use
FunctionProvides Armour Clamp
ConstructionNicote Plated Brass Components
GN Cable Gland
Fitting Instructions1. Screw the gland body into the apparatus.2. Pass the gland sleeve over the cable before commencing to strip the outer sheath of the cable.3. Measure the length of tails required and add about 75mm to the outer sheath and armour to this point.4. Strip the outer sheath.5. Cut the armour wire to the SWA exposed length in the table.6. Pass the armour clamp over the armour.7. Pass the armour cone over the bedding and under the armour wires.8. Pass the bedding through the gland body.9. Engage sleeve thread onto body thread and tighten securely.
GN164GN204GN206GN254GN256GN324GN326GN405GN503GN505GN636GN753GN755
M16 x 1.5 M20 x 1.5M20 x 1.5M25 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.52.5”BSP2.5”BSP
10.0010.0010.0010.0010.0010.0010.0015.0015.0015.0019.0019.0019.00
7.2011.0013.7516.2518.7522.7526.5032.7538.5044.4556.2560.3566.70
10.8017.0020.0022.5026.0030.0034.0041.5049.0055.5068.2573.0079.40
0.90 - 1.250.90 - 1.250.90 - 1.250.90 - 1.251.25 - 1.601.25 - 1.601.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.15
20.525.227.530.333.639.544.554.260.366.782.695.3101.6
21.526.326.326.335.738.738.744.651.354.556.060.060.0
7.4010.4016.6019.6022.1025.6029.6033.6041.1048.6055.1067.8572.60
8.08.08.08.010.512.012.014.015.515.517.521.521.5
30202016864644211
PROTRUSION
CABL
E OV
ERAL
LM
AX
ACRO
SS C
ORNE
RS
MOU
NTIN
G TH
READ
CABL
EO/
BEDD
ING
MAX
BODYSWA
EXPOSED CLAMP SLEEVE
THREADLENGTH
GENERAL PURPOSE CABLE GLAND FOR STEEL WIRED ARMOURED CABLE
Product specifi cations may change at any time without notice.
Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.
5
ApplicationsIndoor and outdoor use
FunctionProvides armour clamp, and sealon outer sheath
Protection ClassIngress of waterIP66/68
ConstructionNicote Plated Brass Components
WGN Cable Gland
Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corner Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.
MOU
NTIN
G TH
READ
CABL
EO/
BEDD
ING
MAX
CABL
E OV
ERAL
LM
AX
PROTRUSION
BODY
IP66/68 GASKETO RINGSEAL CLAMP
SWAEXPOSED
SLEEVE
NEOPRENE SEAL
NUT
ACRO
SS C
ORNE
RS
THREADLENGTH
WGN162WGN164WGN202WGN203WGN204WGN206WGN254WGN256WGN324WGN326WGN403WGN404WGN405WGN502WGN503WGN504WGN505WGN634WGN635WGN636WGN753WGN754WGN755WGN10AWGN10B
M16 x 1.5M16 x 1.5M20 x 1.5M20 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5M63 x 1.52.5”BSP2.5”BSP2.5”BSP3”BSP3”BSP
14141414141414141414151515151515151919191919191919
6.007.208.009.7511.0013.7516.2518.7522.7526.5028.5030.7532.7535.7538.5041.6544.4548.8052.4056.2560.3563.5066.7070.0076.00
9.6010.8012.0015.5017.0020.0022.5026.0030.0034.0037.0039.5041.5045.0049.0053.5055.5060.3563.5068.2573.0076.2079.4084.0088.50
0.50 - 0.90 0.50 - 0.90 0.50 - 0.90 0.90 - 1.250.90 - 1.250.90 - 1.250.90 - 1.251.25 - 1.601.25 - 1.601.60 - 2.001.60 - 2.001.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.15
3.153.15
36 364040404040475555595959737373737979799393939090
8899999111212131313141414141515152222222222
4040303030208688444442211111111
Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.4. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.5. Strip the outer sheath.6. Cut the armour wire to SWA exposed length.7. Pass the armour clamp over the armour.8. Pass the body and armour cone over the bedding and under the armour wires.
WGN10A - B Complete with earth fi xing lug of 1/2” diameter.
9. Engage sleeve thread onto body thread and tighten securely.10. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.11. Tighten gland nut securely.
8.009.2010.4011.6015.1016.6019.6022.1025.6029.6033.6036.6039.1041.1044.6048.6053.1055.1059.9563.1067.8572.6075.8079.0083.60
24.124.125.327.527.533.036.440.749.849.860.960.960.976.076.086.586.5101.9101.9101.9115.6115.6115.6124.0124.0
GENERAL PURPOSE CABLE GLAND FOR STEEL WIRED ARMOURED CABLE
Product specifi cations may change at any time without notice.
6
INNER NEOPRENESEAL
SWAEXPOSED
BODY
IP66/68 GASKETO RINGSEAL
CLAMP
CONESLEEVE
NUTOUTER NEOPRENE SEAL
PROTRUSION
ACRO
SS C
ORNE
RS
MOU
NTIN
G TH
READ
CABL
E OV
ERAL
LM
AX
CABL
EO/
BEDD
ING
MAX
THREADLENGTH
9. Pass the armour cone over the bedding and under the armour wires.10. Pass the bedding through the inner seal in the gland body. N.B. Unless this seal provides a push fi t on the bedding the next size gland will be required. (The minimum dimension over the bedding is embossed on the sleeve of the gland for reference.) On glands over FLWN405 one or two seals are supplied with each gland, select the most suitable seal.11. Engage sleeve thread onto body thread and tighten securely.12. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.13. Tighten gland nut securely.
FLWN Cable GlandApplicationsIndoor and Outdoor use in hazardous areas
StandardsAS 1828 - 1984 AS1939 - 1990
FunctionProvides O/Bledding Flameproof Seal, ArmourClamp and Seal on Outer Sheath
Protection ClassAus Ex 591 Ex I/IICMDA Ex G0391QMDA 36/15Ingress of waterIP66/68 (30m)
ConstructionNicote Plated Brass Components
Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Leave the inner seal in the gland body.4. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.5. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.6. Strip the outer sheath.7. Cut the armour wire to SWA exposed length.8. Pass the armour clamp over the armour.
FLAMEPROOF CABLE GLAND FOR STEEL WIRE ARMOURED CABLE
Product specifi cations may change at any time without notice.
Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length Overbedding Overall Diameter SWA Across SWA Carton (mm) (mm) Min. Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.
FLWN202 M20 x 1.5 15.80 6.00 8.00 10.00 12.00 0.50 - 0.90 25 54 12 30FLWN203 M20 x 1.5 15.80 8.30 9.75 11.60 15.50 0.90 - 1.25 27 54 12 30FLWN204 M20 x 1.5 15.80 9.35 11.00 15.10 17.00 0.90 - 1.25 27 54 12 30FLWN205 M20 x 1.5 15.80 10.60 12.50 16.60 20.00 0.90 - 1.25 33 54 12 20FLWN206 M20 x 1.5 15.80 12.00 13.75 16.60 20.00 0.90 - 1.25 33 54 12 20FLWN253 M25 x 1.5 19.00 13.35 15.00 19.60 22.50 0.90 - 1.25 36 56 12 14FLWN254 M25 x 1.5 19.00 14.60 16.25 19.60 22.50 0.90 - 1.25 36 56 12 14FLWN255 M25 x 1.5 19.00 15.85 17.50 22.10 26.00 1.25 - 1.60 41 56 12 12FLWN256 M25 x 1.5 19.00 17.10 18.75 22.10 26.00 1.25 - 1.60 41 56 12 12FLWN323 M32 x 1.5 25.40 18.35 20.75 25.60 30.00 1.25 - 1.60 50 64 13 8FLWN324 M32 x 1.5 25.40 20.35 22.75 25.60 30.00 1.25 - 1.60 50 64 13 8FLWN325 M32 x 1.5 25.40 22.35 24.75 29.60 34.00 1.60 - 2.00 50 64 13 8FLWN326 M32 x 1.5 25.40 24.35 26.50 29.60 34.00 1.60 - 2.00 50 64 13 8FLWN403 M40 x 1.5 25.40 26.10 28.50 33.60 37.00 1.60 - 2.00 61 72 15 1FLWN404 M40 x 1.5 25.40 28.10 30.75 36.60 39.50 1.60 - 2.00 61 72 15 1FLWN405 M40 x 1.5 25.40 30.35 32.75 39.10 41.50 1.60 - 2.00 61 72 15 1FLWN502 M50 x 1.5 28.60 32.35 35.75 41.10 45.00 2.00 - 2.50 76 88 18 2FLWN503 M50 x 1.5 28.60 35.35 38.50 44.60 49.00 2.00 - 2.50 76 88 18 2FLWN504 M50 x 1.5 28.60 38.10 41.65 48.60 53.50 2.00 - 2.50 87 88 18 2FLWN505 M50 x 1.5 28.60 41.25 44.45 53.10 55.50 2.00 - 2.50 87 88 18 2FLWN633 M63 x 1.5 28.60 44.05 46.00 55.10 57.15 2.00 - 2.50 99 96 21 1FLWN634 M63 x 1.5 28.60 45.60 48.80 56.75 60.35 2.50 - 3.15 99 96 21 1FLWN635 M63 x 1.5 28.60 48.40 52.40 59.95 63.50 2.50 - 3.15 102 96 21 1FLWN636 M63 x 1.5 28.60 52.00 56.25 63.10 68.25 2.50 - 3.15 102 96 21 1FLWN753 2.5” BSP 28.60 55.85 60.35 67.85 73.00 2.50 - 3.15 116 100 25 1FLWN754 2.5” BSP 28.60 59.95 63.50 72.60 76.20 2.50 - 3.15 116 100 25 1FLWN755 2.5” BSP 28.60 63.10 66.70 75.80 79.40 2.50 - 3.15 116 100 25 1
7
Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.
Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Pass Nut, Seal and Sleeve over the outer sheath of cable (Where more than 1 seal is supplied, use the seal with the smallest clearance on the cable).3. Measure the length of cores required and strip the outer sheath and armour wires to the length shown in Table 1.4. Remove the Bedding and any fi llers to the length shown in Table 2.5. Slide the clamp over the armour wires and work the Cone over the bedding and under the SWA.6. Locate the Body onto the Cores and hold hard against the face of the Cone. Screw the Sleeve onto the Body and tighten, now tighten the nut onto the sleeve.7. Remove the Body from the assembly.8. Prepare the epoxy putty. This is a 2 part pack and must be mixed in a ratio of 1 to 1 until the colour is even throughout, without any streaks. After mixing it remains pliable for at least 1 hour. (see Useable Life for Mixed Epoxy below)
Note: The Red Epoxy component is affected by storage temperature. Please check to ensure this component is as pliable as the yellow component. It is recommended that the epoxy should be mixed and fi tted only with the user wearing the disposable gloves supplied with every gland.
9. Spread the conductors and apply to epoxy to the EXPOSED CENTRE of the conductors. Close the conductors and pack putty into the recess of the cone and down onto the top of the bedding material leaving a shoulder of putty to fi ll the sleeve cup.
ApplicationsIndoor and Outdoor use in hazardous areas
StandardsAS 1828 - 1984 AS1939 - 1990
FunctionProvides Barrier Epoxy Seal to Cable Cores,Armour Clamp, and Seal on Outer Sheath
Protection ClassAus Ex 3096X Ex I/IICMDA ExdU14074Ingress of waterIP66/68 (30m)
ConstructionNicote Plated Brass Components
FLPWB Cable Gland
FLPW203BFLPW206BFLPW256BFLPW326BFLPW405BFLPW503BFLPW505BFLPW635BFLPW636BFLPW754BFLPW755B
M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5
2.5”BSP2.5”BSP
15.8015.8019.0025.4025.4028.6028.6028.6028.6028.6028.60
9.7513.7518.7526.5032.7538.5044.4552.4056.2563.5066.70
15.5020.0026.0034.0041.5049.0055.5063.5068.2576.2079.40
0.90 - 1.25 0.90 - 1.251.25 - 1.601.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.15
27334150617687102102116116
545456647288889696100100
11.6015.1019.6025.6033.6041.1048.6055.1063.1067.8575.80
11.511.511.513.515.5171719192323
14141062221111
MOU
NTIN
G TH
READ
CABL
EO/
BEDD
ING
MAX
EPOXY
PROTRUSION
CABL
E OV
ERAL
LM
AXAC
ROSS
COR
NERS
CLAMPSWA
EXPOSEDSLEEVE
NUTOUTER NEOPRENE SEALCONE
BODY SLEEVEO RINGSEAL
IP66/68 GASKETBODY
THREADLENGTH
Continue folding putty round the conductors and working it well in between them, joining with that extruded from the core center avoiding any gaps or voids. Cover the conductors from the face of the cone to the length equal at least to the length of the Sleeve.
10. Assemble the Sleeve over the epoxy until it fi ts into the Cone. Remove any surplus epoxy.
11. Reassemble the Body, tighten and allow at least three hours for the epoxy to reach correct hardness.
12. Remove the Body, fi t to the equipment the reassemble completed fi tting.
TABLE 1 TABLE 2Gland mm
FLPW203B
FLPW206B
FLPW256B
FLPW326B
FLPW405B
FLPW503B
FLPW505B
FLPW635B
FLPW636B
FLPW754B
FLPW755B
11.50
11.50
11.50
13.50
15.50
17.00
17.00
19.00
19.00
23.00
23.00
Gland mm
FLPW203B
FLPW206B
FLPW256B
FLPW326B
FLPW405B
FLPW503B
FLPW505B
FLPW635B
FLPW636B
FLPW754B
FLPW755B
13.50
13.50
13.50
15.50
17.50
17.50
19.50
21.00
21.00
25.00
25.00
Useable Life for Mixed EpoxyThis will depend upon the bulk mass and temperature. 25 grams wt 2 hours @ 25deg. CApproximate fi gures are: 25 grams wt 3 hours @ 15deg. C
CureThis will depend upon the bulk mass and temperature. 25 grams wt 12 hours @ 25deg. CApproximate fi gures are: 25 grams wt 24 hours @ 15deg. C
Mechanical properties of cured mixTensile strength BS6319 2 days min. 30MPaCompressive strength BS6319 2 days min. 40MPaHardness min 75 shore DSpecifi c Gravity @ 20 deg. C 1.84 to 1.99
BARRIER CABLE GLAND FOR STEEL WIRE ARMOURED CABLE
Product specifi cations may change at any time without notice.
8
Earth Tags
Cable Gland Accessories
E16E20E25E32E40E50E63
M16M20M25M32M40M50M63
TBA20010050502525
6.356.356.356.356.356.356.35
Locknuts
Extension Nuts for UFPN Glands
L12LNB-16LNB-20LNB-25LNB-32LNB-40LNB-50LNB-63
L250L275L300L325L350L400
1/2” X 26 TPI M16 x 1.5
M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M63 x 1.52.5 BSP2.75 BSP3.0 BSP3.25 BSP3.5 BSP4.0 BSP
100100100100100402520666664
EN20AEN20BEN20CEN25AEN32AEN32B
403739424547
282831364246
181410886
Part Suits Cable Gland Inner Number Gland Across Carton Corners Protrusion Pack (mm) (mm) Quantity
Orange Shrouds
ACROSS FLATS
MOUNTING THREAD
MOU
NTIN
G TH
READ
DIAM
ETER
EART
H BO
LTDI
AMET
ER
CUT LINE FORMINIMUM CABLE
DIAMETER
SHROUDNUMBER
TO SUIT GLANDFROM SELECTION
CHART
PROTRUSION
EXTENSION NUT
ACRO
SS C
ORNE
RS
FLPW203B
FLPW206B
FLPW256B
FLPW326B
FLPW405B
FLPW503B
FLWN202FLWN203FLWN204FLWN205FLWN206FLWN253FLWN254FLWN255FLWN256FLWN323FLWN324FLWN325FLWN326FLWN403FLWN404FLWN405FLWN502FLWN503
WGN162WGN164WGN202WGN203WGN204
WGN206WGN254WGN256
WGN324WGN326
WGN403WGN404WGN405WGN502WGN503
S0-Orange
S1-Orange
S2-Orange
S3-Orange
S4-Orange
S5-Orange
S6-Orange
S7-Orange
UN20AUN20B
UN25A
UN32A
UN40A
UN40BUN50A
UN50BUN63A
UN63B
UFPN20AUFPN20B
UFPN20C
UFPN25A
UFPN32A
UFPN32B
UFPN40AUFPN40B
UFPN50AUFPN50B
UFPN63AUFPN63B
GN204GN206GN254GN256
GN324GN326
GN405
GN503GN505
GN636
Part Mounting Earth Inner Number Thread Bolt Carton Diameter Pack (mm) Quantity
Part Mounting Across Inner Number Thread Flats Carton Hexagon Pack (mm) Quantity
1620.727
31.640
48.257.38294102116116124140
150
140
110
90
70
50
40
18
9
Part Cable Gland Number UN UFPN GN WGN FLWN FLPWB Carton Pack Quantity
UFPN20AUFPN20BUFPN20CUFPN25AUFPN32AUFPN32B
Nicote Accessories
UB4PUB8P
UB13P
UB17PUB22P
UB27P
UB31P
UB36PUB41P
UB45P
UB117P
UB118PUB119P
UB517P
UB518P
WGN162WGN164WGN202WGN203WGN204WGN206
WGN254WGN256
WGN324WGN326
WGN403WGN404WGN405
WGN502WGN503WGN504WGN505WGN634WGN635WGN636
WGN753WGN754WGN755
WGN10AWGN10B
1/2”M16
M20
M20M25
M32
M40
M50M50
M63
2.5” BSP
2.75” BSP3” BSP
3.5” BSP
4” BSP
UN12AUN16A
UN20A
UN20BUN25A
UN32A
UN40AUN40B
UN50AUN50B
UN63AUN63B
FLWN202FLWN203FLWN204FLWN205FLWN206
FLWN253FLWN254FLWN255FLWN256FLWN323FLWN324FLWN325FLWN326FLWN403FLWN404FLWN405
FLWN502FLWN503FLWN504FLWN505FLWN633FLWN634FLWN635FLWN636FLWN753FLWN754FLWN755
UFPN20AUFPN20BUFPN20C
UFPN25A
UFPN32AUFPN32B
UFPN40AUFPN40B
UFPN50AUFPN50B
UFPN63AUFPN63B
UFPN250A
UFPN275AUFPN300A
UFPN350AUFPN350BUFPN400AUFPN400B
FLPW203BFLPW206B
FLPW256B
FLPW326B
FLPW405B
FLPW503BFLPW505B
FLPW635BFLPW636B
FLPW754BFLPW755B
100100
100
100100
100
100
100100
20
20
2020
20
20
IP66/68 GASKETAs supplied with glands
Fibre Gasket
Part Mounting Cable Gland Number Thread UN UFPN WGN FLWN FLPWB Carton Size Pack Quantity
10
ApplicationsIndoor and outdoor use in harsh environments
StandardsAS 1939 - 1990
FunctionProvides seal on cable sheath
Protection ClassIP65
ConstructionBody and compression nut316 Stainless Steel
SSG Cable GlandGENERAL PURPOSE STAINLESS STEEL CABLE GLANDS
Thomas & Betts Stainless Steel Cable
Glands are high quality glands designed
for use in severe environments. Made
from 316 grade stainless steel, each
gland features a wide cable diameter
range and UP65 protection.
8.411.516.321
27.7
3.56.4111519
M16x1.5M20x1.5M20x1.5M25x1.5M32x1.5
Part Mounting Cable Acceptance Number Thread Details Across Pack Size Length Overall Diameter Corners Qty (mm) (mm) Min (mm) Max (mm) (mm)
SSG-16-8SSG-20-11SSG-20-16
SSG-25SSG-32
1010121212
5025252510
2222
27.53240
Part Mounting Cable Acceptance Number Thread Details Across Pack Size Length Overall Diameter Corners Qty (mm) (mm) Min (mm) Max (mm) (mm)
SCG-20-10SSG-20-13
M20x1.5M20x1.5
1010
6.510
1013.5
2228
2525
ApplicationsIndoor and outdoor use with EMCscreened cables
FunctionProvides seal on cable sheathand earthing of screen
Protection ClassIP65
ConstructionBody and compression nutNickel plated brass,
EMC Cable GlandCABLE GLAND FOR EMC SCREENED CABLE
Thomas & Betts EMC Cable Glands are
high quality glands designed for use with
EMC screened cables using a garter spring
to earth the screen. EMC glands can also
be used with Belden Armoured Cables.
MOU
NTIN
G TH
READ
ACRO
SS C
ORNE
RS
CABL
E OV
ERAL
L
MAX
BODY
SEAL
SKID WASHER
NUT
PROTRUSIONTHREADLENGTH
GARTER SPRING
SCREEN EXPOSED
COMPRESSION RINGSSEAL
NUT
PROTRUSION
BODY
MOU
NTIN
G TH
READ
CABL
E OV
ERAL
LM
AX
ACRO
SS C
ORNE
RS
SKID WASHER
THREADLENGTH
Prod
uct
spec
ifi ca
tions
may
cha
nge
at a
ny t
ime
with
out
notic
e.
Prod
uct
spec
ifi ca
tions
may
cha
nge
at a
ny t
ime
with
out
notic
e.
Fitting Instructions1. Screw the gland body into the apparatus.2. Measure the length of tails required and add about 15 mm to this point.3. Strip the outer sheath.4. Cut the screen so that approx 15mm is exposed.5. Pass the cable through the gland and ensure that the exposed screen aligns with the garter spring.5. Tighten gland nut so that the seal grips fi rmly onto the cable.
11
For further information on Thomas & Betts products and services Phone 1300 666 595 Fax 1300 666 594 www.tnbaust.com
Thomas & Betts Australasia Pty Ltd Head Offi ce & Manufacturing 23A Nyrang Street, Lidcombe, NSW 2141
ABN 62 074 810 898