Thomas & Betts Nylon Cable Glands are quick & easy to install with a high quality gripping claw/seal arrangement that caters

for a wide range of cable sizes per fi tting. Each gland has no loose parts and requires no disassembly for cable installation.

LOCKNUT WASHER BODY CLAW SEALS NUT

ACRO

SS C

ORNE

RS

CABL

EOV

ERAL

LM

AX

MOU

NTIN

GTH

READ

THREADLENGTH

NG Cable GlandGENERAL PURPOSE NYLON CABLE GLANDS

Thomas & Betts, a global leader in the design, manufacture and marketing of electrical products and

accessories is proud to be appointed exclusive distributor of the Nicote range of metal cable glands.

This new catalogue not only details the full Nicote range, but presents the entire Thomas & Betts

range of cable glands from the general purpose NG Nylon range through to 316 Stainless steel

models designed to deliver superior performance in harsh environments.

Thomas & Betts Australasia is proudly committed to delivering innovative solutions to its valued

customers through experienced sales and service teams in each state and the National Customer

Support Centre. Should you not fi nd what you are looking for in this catalogue or need further

information please contact us on 1300 666 595.

ApplicationsIndoor and outdoor use

StandardsAS1939 - 1990

FunctionProvides seal on cable sheath

Protection ClassIP68, Resistant to salt water, weak alcohol, oil, grease and common solvents

ConstructionBody - UL approved Nylon 66 (Black)Seal - EPDM Rubber

Thread TypeMetric with locknut and IP68 washer

Part Mounting Thread Cable Acceptance Details Number Size Length Overall Diameter Across Pack (mm) (mm) Min. Max. Corners Qty. (mm) (mm) (mm)

152227273341506275

50 50 25 25 25 10 10 2 2

NG-12NG-16NG-20NG-20-2.5TPSNG-25NG-32NG-40 NG-50NG-63

151515151515152020

4 6

8.52.5mm TPS

12.518243040

71014

N/A1825324151

M12 x 1.5 M16 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M63 x 1.5

Product specifi cations may change at any time without notice.

1

Page 3: Cable Gland

Make no mistake, the Nicote range of metal cable glands are your guarantee of safety

in hazardous locations especially where fi re and explosion are an identifi ed risk.

Experience counts for a lot when it comes to safety, and the Nicote range is designed and

manufactured by the original Australian producer of the successful Alco brand of glands. Since

1962, Reliance Worldwide has been perfecting their metal cable gland designs and incorporating

the latest high performance materials. The current Nicote range is quite simply the best available

because they do not compromise on safety – and that’s what counts!

Take a look at just some of the features that make Nicote the fi rst choice:

Highly durable nickel platingNicote glands are coated in a proprietary 2 coat plating process that ensures all metal

components will not degrade and potentially let you down over time.

Comprehensive RangeThe greater the range of cable sizes a gland is designed to cover, the higher the risk of seals

failing. Nicote contains a comprehensive range with smaller cable acceptance increments

that also allows the gland bodies to be smaller and hence easier to use when space is tight.

Full ApprovalsDon’t just take our word for it, independent test bodies have confi rmed that the Nicote gland

range complies with relevant standards including approvals for use in mining.

Neoprene SealsAll Nicote glands use high quality Neoprene seals that retain their tension and are resistant to oil,

chemicals and fl ame making them the best choice for hazardous applications.

IP66/68 ProtectionAll Nicote glands classifi ed for indoor/outdoor use are supplied with IP66/68 gaskets for

installation on the mounting thread and neoprene seals on the cable sheath. This level

of protection means that the glands are protected from the ingress of dust and water.

Anything less is unacceptable and compromises safety.

O’Ring SealsAll Nicote glands designed for SWA cable and classifi ed for indoor/outdoor use, feature o’ring

seals between the body and sleeve to ensure that water cannot progress along the thread

and compromise the seal. Just another safety feature.

Easy to useThe ability to easily produce a tight seal and correct earth everytime is of primary importance.

All Nicote glands are designed to be easy to use and to ensure that the installer can see that

the correct fi tting instructions have been followed. For example, all SWA fl ameproof glands

feature a loose clamping cone so that the installer can see that the armour is fully secured.

Technical backingThe Nicote range enjoys the backing of both Thomas & Betts and Reliance Worldwide,

both world reknown manufacturers of quality electrical accessories.

When safety matters, there is only one choice.

Introduction

2

Page 4: Cable Gland

MOU

NTIN

G TH

READ

ACRO

SS C

ORNE

RS

CABL

E OV

ERAL

L

MAX

BODY

IP66/68 GASKET NEOPRENE SEAL

SKID WASHER

NUT

PROTRUSIONTHREADLENGTH

UN12AUN16AUN20AUN20BUN25AUN32AUN40A UN40BUN50A UN50B UN63AUN63B

101010101010161616161919

1.0 1.0 6.010.615.020.025.030.035.040.045.050.0

6.06.010.615.020.025.030.035.040.045.050.055.0

18.320.627.530.933.040.751.155.060.967.078.088.0

131314161718212323242532

60403040408866662

1/2” x 26 TPI M16 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5

Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus, or use a locknut to secure body.3. Pass the cable through the gland to the required position and tighten gland nut so that the seal grips fi rmly onto the cable.

Part Mounting Thread Cable Acceptance Details Cable Gland InnerNumber Size Length Overall Diameter Across Carton (mm) (mm) Min. Max. Corners Protrusion Pack (mm) (mm) (mm) (mm) Qty.

UN Cable GlandGENERAL PURPOSE CABLE GLAND FOR CIRCULAR CABLE

Product specifi cations may change at any time without notice.

3

ApplicationsIndoor and Outdoor use in hazardous areas

StandardsAS1939 - 1990

FunctionProvides Seal on Cable Sheath

Protection ClassIngress of waterIP66/68 (30m)

ConstructionNicote Plated Brass Components

Page 5: Cable Gland

ApplicationsIndoor and Outdoor use in hazardous areas

StandardsAS 1828 - 1984 AS1939 - 1990

FunctionProvides Flameproof Seal on Cable Sheath

Protection ClassAus Ex 2420U Ex I/IICMDA 11641Ingress of waterIP66/68 (40m)

ConstructionNicote Plated Brass Components

Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Pass the cable through the gland to the required position and tighten gland nut so that the seal grips fi rmly onto the cable.

PROTRUSION

ACRO

SS C

ORNE

RS

MOU

NTIN

G TH

READ

BODY

CABL

E OV

ERAL

LM

AX

IP66/68 GASKET NEOPRENE SEAL SKID WASHER

NUT

THREADLENGTH

UFPN20AUFPN20BUFPN20CUFPN25AUFPN32AUFPN32BUFPN40AUFPN40BUFPN50AUFPN50BUFPN63AUFPN63BUFPN250AUFPN275AUFPN300AUFPN350AUFPN350BUFPN400AUFPN400B

M20 x 1.5 M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.52.5”BSP2.75”BSP3.0”BSP3.5”BSP3.5”BSP4.0”BSP4.0”BSP

6.29.112.014.518.221.925.630.034.239.144.048.755.562.469.376.183.089.996.6

9.112.014.518.221.925.630.034.239.144.048.755.562.469.376.183.089.996.6103.0

28283136424652557274888898107115129129143143

21182023232525253133343435363648484848

303020161288622222111111

UFPN Cable GlandFLAMEPROOF CABLE GLAND FOR CIRCULAR CABLE

12.712.712.715202021212828282828353538383838

Product specifi cations may change at any time without notice.

Part Mounting Thread Cable Acceptance Details Cable Gland InnerNumber Size Length Overall Diameter Across Carton (mm) (mm) Min. Max. Corners Protrusion Pack (mm) (mm) (mm) (mm) Qty.

4

Page 6: Cable Gland

ApplicationsIndoor use

FunctionProvides Armour Clamp

ConstructionNicote Plated Brass Components

GN Cable Gland

Fitting Instructions1. Screw the gland body into the apparatus.2. Pass the gland sleeve over the cable before commencing to strip the outer sheath of the cable.3. Measure the length of tails required and add about 75mm to the outer sheath and armour to this point.4. Strip the outer sheath.5. Cut the armour wire to the SWA exposed length in the table.6. Pass the armour clamp over the armour.7. Pass the armour cone over the bedding and under the armour wires.8. Pass the bedding through the gland body.9. Engage sleeve thread onto body thread and tighten securely.

GN164GN204GN206GN254GN256GN324GN326GN405GN503GN505GN636GN753GN755

M16 x 1.5 M20 x 1.5M20 x 1.5M25 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.52.5”BSP2.5”BSP

10.0010.0010.0010.0010.0010.0010.0015.0015.0015.0019.0019.0019.00

7.2011.0013.7516.2518.7522.7526.5032.7538.5044.4556.2560.3566.70

10.8017.0020.0022.5026.0030.0034.0041.5049.0055.5068.2573.0079.40

0.90 - 1.250.90 - 1.250.90 - 1.250.90 - 1.251.25 - 1.601.25 - 1.601.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.15

20.525.227.530.333.639.544.554.260.366.782.695.3101.6

21.526.326.326.335.738.738.744.651.354.556.060.060.0

7.4010.4016.6019.6022.1025.6029.6033.6041.1048.6055.1067.8572.60

8.08.08.08.010.512.012.014.015.515.517.521.521.5

30202016864644211

PROTRUSION

CABL

E OV

ERAL

LM

AX

ACRO

SS C

ORNE

RS

MOU

NTIN

G TH

READ

CABL

EO/

BEDD

ING

MAX

BODYSWA

EXPOSED CLAMP SLEEVE

THREADLENGTH

GENERAL PURPOSE CABLE GLAND FOR STEEL WIRED ARMOURED CABLE

Product specifi cations may change at any time without notice.

Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.

5

Page 7: Cable Gland

ApplicationsIndoor and outdoor use

FunctionProvides armour clamp, and sealon outer sheath

Protection ClassIngress of waterIP66/68

ConstructionNicote Plated Brass Components

WGN Cable Gland

Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corner Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.

MOU

NTIN

G TH

READ

CABL

EO/

BEDD

ING

MAX

CABL

E OV

ERAL

LM

AX

PROTRUSION

BODY

IP66/68 GASKETO RINGSEAL CLAMP

SWAEXPOSED

SLEEVE

NEOPRENE SEAL

NUT

ACRO

SS C

ORNE

RS

THREADLENGTH

WGN162WGN164WGN202WGN203WGN204WGN206WGN254WGN256WGN324WGN326WGN403WGN404WGN405WGN502WGN503WGN504WGN505WGN634WGN635WGN636WGN753WGN754WGN755WGN10AWGN10B

M16 x 1.5M16 x 1.5M20 x 1.5M20 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5M63 x 1.52.5”BSP2.5”BSP2.5”BSP3”BSP3”BSP

14141414141414141414151515151515151919191919191919

6.007.208.009.7511.0013.7516.2518.7522.7526.5028.5030.7532.7535.7538.5041.6544.4548.8052.4056.2560.3563.5066.7070.0076.00

9.6010.8012.0015.5017.0020.0022.5026.0030.0034.0037.0039.5041.5045.0049.0053.5055.5060.3563.5068.2573.0076.2079.4084.0088.50

0.50 - 0.90 0.50 - 0.90 0.50 - 0.90 0.90 - 1.250.90 - 1.250.90 - 1.250.90 - 1.251.25 - 1.601.25 - 1.601.60 - 2.001.60 - 2.001.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.15

3.153.15

36 364040404040475555595959737373737979799393939090

8899999111212131313141414141515152222222222

4040303030208688444442211111111

Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.4. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.5. Strip the outer sheath.6. Cut the armour wire to SWA exposed length.7. Pass the armour clamp over the armour.8. Pass the body and armour cone over the bedding and under the armour wires.

WGN10A - B Complete with earth fi xing lug of 1/2” diameter.

9. Engage sleeve thread onto body thread and tighten securely.10. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.11. Tighten gland nut securely.

8.009.2010.4011.6015.1016.6019.6022.1025.6029.6033.6036.6039.1041.1044.6048.6053.1055.1059.9563.1067.8572.6075.8079.0083.60

24.124.125.327.527.533.036.440.749.849.860.960.960.976.076.086.586.5101.9101.9101.9115.6115.6115.6124.0124.0

GENERAL PURPOSE CABLE GLAND FOR STEEL WIRED ARMOURED CABLE

Product specifi cations may change at any time without notice.

6

Page 8: Cable Gland

INNER NEOPRENESEAL

SWAEXPOSED

BODY

IP66/68 GASKETO RINGSEAL

CLAMP

CONESLEEVE

NUTOUTER NEOPRENE SEAL

PROTRUSION

ACRO

SS C

ORNE

RS

MOU

NTIN

G TH

READ

CABL

E OV

ERAL

LM

AX

CABL

EO/

BEDD

ING

MAX

THREADLENGTH

9. Pass the armour cone over the bedding and under the armour wires.10. Pass the bedding through the inner seal in the gland body. N.B. Unless this seal provides a push fi t on the bedding the next size gland will be required. (The minimum dimension over the bedding is embossed on the sleeve of the gland for reference.) On glands over FLWN405 one or two seals are supplied with each gland, select the most suitable seal.11. Engage sleeve thread onto body thread and tighten securely.12. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.13. Tighten gland nut securely.

FLWN Cable GlandApplicationsIndoor and Outdoor use in hazardous areas

StandardsAS 1828 - 1984 AS1939 - 1990

FunctionProvides O/Bledding Flameproof Seal, ArmourClamp and Seal on Outer Sheath

Protection ClassAus Ex 591 Ex I/IICMDA Ex G0391QMDA 36/15Ingress of waterIP66/68 (30m)

ConstructionNicote Plated Brass Components

Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Leave the inner seal in the gland body.4. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.5. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.6. Strip the outer sheath.7. Cut the armour wire to SWA exposed length.8. Pass the armour clamp over the armour.

FLAMEPROOF CABLE GLAND FOR STEEL WIRE ARMOURED CABLE

Product specifi cations may change at any time without notice.

Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length Overbedding Overall Diameter SWA Across SWA Carton (mm) (mm) Min. Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.

FLWN202 M20 x 1.5 15.80 6.00 8.00 10.00 12.00 0.50 - 0.90 25 54 12 30FLWN203 M20 x 1.5 15.80 8.30 9.75 11.60 15.50 0.90 - 1.25 27 54 12 30FLWN204 M20 x 1.5 15.80 9.35 11.00 15.10 17.00 0.90 - 1.25 27 54 12 30FLWN205 M20 x 1.5 15.80 10.60 12.50 16.60 20.00 0.90 - 1.25 33 54 12 20FLWN206 M20 x 1.5 15.80 12.00 13.75 16.60 20.00 0.90 - 1.25 33 54 12 20FLWN253 M25 x 1.5 19.00 13.35 15.00 19.60 22.50 0.90 - 1.25 36 56 12 14FLWN254 M25 x 1.5 19.00 14.60 16.25 19.60 22.50 0.90 - 1.25 36 56 12 14FLWN255 M25 x 1.5 19.00 15.85 17.50 22.10 26.00 1.25 - 1.60 41 56 12 12FLWN256 M25 x 1.5 19.00 17.10 18.75 22.10 26.00 1.25 - 1.60 41 56 12 12FLWN323 M32 x 1.5 25.40 18.35 20.75 25.60 30.00 1.25 - 1.60 50 64 13 8FLWN324 M32 x 1.5 25.40 20.35 22.75 25.60 30.00 1.25 - 1.60 50 64 13 8FLWN325 M32 x 1.5 25.40 22.35 24.75 29.60 34.00 1.60 - 2.00 50 64 13 8FLWN326 M32 x 1.5 25.40 24.35 26.50 29.60 34.00 1.60 - 2.00 50 64 13 8FLWN403 M40 x 1.5 25.40 26.10 28.50 33.60 37.00 1.60 - 2.00 61 72 15 1FLWN404 M40 x 1.5 25.40 28.10 30.75 36.60 39.50 1.60 - 2.00 61 72 15 1FLWN405 M40 x 1.5 25.40 30.35 32.75 39.10 41.50 1.60 - 2.00 61 72 15 1FLWN502 M50 x 1.5 28.60 32.35 35.75 41.10 45.00 2.00 - 2.50 76 88 18 2FLWN503 M50 x 1.5 28.60 35.35 38.50 44.60 49.00 2.00 - 2.50 76 88 18 2FLWN504 M50 x 1.5 28.60 38.10 41.65 48.60 53.50 2.00 - 2.50 87 88 18 2FLWN505 M50 x 1.5 28.60 41.25 44.45 53.10 55.50 2.00 - 2.50 87 88 18 2FLWN633 M63 x 1.5 28.60 44.05 46.00 55.10 57.15 2.00 - 2.50 99 96 21 1FLWN634 M63 x 1.5 28.60 45.60 48.80 56.75 60.35 2.50 - 3.15 99 96 21 1FLWN635 M63 x 1.5 28.60 48.40 52.40 59.95 63.50 2.50 - 3.15 102 96 21 1FLWN636 M63 x 1.5 28.60 52.00 56.25 63.10 68.25 2.50 - 3.15 102 96 21 1FLWN753 2.5” BSP 28.60 55.85 60.35 67.85 73.00 2.50 - 3.15 116 100 25 1FLWN754 2.5” BSP 28.60 59.95 63.50 72.60 76.20 2.50 - 3.15 116 100 25 1FLWN755 2.5” BSP 28.60 63.10 66.70 75.80 79.40 2.50 - 3.15 116 100 25 1

7

Page 9: Cable Gland

Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.

Fitting Instructions1. To comply with IP66/68 approvals, the fi bre gasket must be installed on the mounting thread.2. Pass Nut, Seal and Sleeve over the outer sheath of cable (Where more than 1 seal is supplied, use the seal with the smallest clearance on the cable).3. Measure the length of cores required and strip the outer sheath and armour wires to the length shown in Table 1.4. Remove the Bedding and any fi llers to the length shown in Table 2.5. Slide the clamp over the armour wires and work the Cone over the bedding and under the SWA.6. Locate the Body onto the Cores and hold hard against the face of the Cone. Screw the Sleeve onto the Body and tighten, now tighten the nut onto the sleeve.7. Remove the Body from the assembly.8. Prepare the epoxy putty. This is a 2 part pack and must be mixed in a ratio of 1 to 1 until the colour is even throughout, without any streaks. After mixing it remains pliable for at least 1 hour. (see Useable Life for Mixed Epoxy below)

Note: The Red Epoxy component is affected by storage temperature. Please check to ensure this component is as pliable as the yellow component. It is recommended that the epoxy should be mixed and fi tted only with the user wearing the disposable gloves supplied with every gland.

9. Spread the conductors and apply to epoxy to the EXPOSED CENTRE of the conductors. Close the conductors and pack putty into the recess of the cone and down onto the top of the bedding material leaving a shoulder of putty to fi ll the sleeve cup.

ApplicationsIndoor and Outdoor use in hazardous areas

StandardsAS 1828 - 1984 AS1939 - 1990

FunctionProvides Barrier Epoxy Seal to Cable Cores,Armour Clamp, and Seal on Outer Sheath

Protection ClassAus Ex 3096X Ex I/IICMDA ExdU14074Ingress of waterIP66/68 (30m)

ConstructionNicote Plated Brass Components

FLPWB Cable Gland

FLPW203BFLPW206BFLPW256BFLPW326BFLPW405BFLPW503BFLPW505BFLPW635BFLPW636BFLPW754BFLPW755B

M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5

2.5”BSP2.5”BSP

15.8015.8019.0025.4025.4028.6028.6028.6028.6028.6028.60

9.7513.7518.7526.5032.7538.5044.4552.4056.2563.5066.70

15.5020.0026.0034.0041.5049.0055.5063.5068.2576.2079.40

0.90 - 1.25 0.90 - 1.251.25 - 1.601.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.15

27334150617687102102116116

545456647288889696100100

11.6015.1019.6025.6033.6041.1048.6055.1063.1067.8575.80

11.511.511.513.515.5171719192323

14141062221111

MOU

NTIN

G TH

READ

CABL

EO/

BEDD

ING

MAX

EPOXY

PROTRUSION

CABL

E OV

ERAL

LM

AXAC

ROSS

COR

NERS

CLAMPSWA

EXPOSEDSLEEVE

NUTOUTER NEOPRENE SEALCONE

BODY SLEEVEO RINGSEAL

IP66/68 GASKETBODY

THREADLENGTH

Continue folding putty round the conductors and working it well in between them, joining with that extruded from the core center avoiding any gaps or voids. Cover the conductors from the face of the cone to the length equal at least to the length of the Sleeve.

10. Assemble the Sleeve over the epoxy until it fi ts into the Cone. Remove any surplus epoxy.

11. Reassemble the Body, tighten and allow at least three hours for the epoxy to reach correct hardness.

12. Remove the Body, fi t to the equipment the reassemble completed fi tting.

TABLE 1 TABLE 2Gland mm

FLPW203B

FLPW206B

FLPW256B

FLPW326B

FLPW405B

FLPW503B

FLPW505B

FLPW635B

FLPW636B

FLPW754B

FLPW755B

11.50

11.50

11.50

13.50

15.50

17.00

17.00

19.00

19.00

23.00

23.00

Gland mm

FLPW203B

FLPW206B

FLPW256B

FLPW326B

FLPW405B

FLPW503B

FLPW505B

FLPW635B

FLPW636B

FLPW754B

FLPW755B

13.50

13.50

13.50

15.50

17.50

17.50

19.50

21.00

21.00

25.00

25.00

Useable Life for Mixed EpoxyThis will depend upon the bulk mass and temperature. 25 grams wt 2 hours @ 25deg. CApproximate fi gures are: 25 grams wt 3 hours @ 15deg. C

CureThis will depend upon the bulk mass and temperature. 25 grams wt 12 hours @ 25deg. CApproximate fi gures are: 25 grams wt 24 hours @ 15deg. C

Mechanical properties of cured mixTensile strength BS6319 2 days min. 30MPaCompressive strength BS6319 2 days min. 40MPaHardness min 75 shore DSpecifi c Gravity @ 20 deg. C 1.84 to 1.99

BARRIER CABLE GLAND FOR STEEL WIRE ARMOURED CABLE

Product specifi cations may change at any time without notice.

8

Page 10: Cable Gland

Earth Tags

Cable Gland Accessories

E16E20E25E32E40E50E63

M16M20M25M32M40M50M63

TBA20010050502525

6.356.356.356.356.356.356.35

Locknuts

Extension Nuts for UFPN Glands

L12LNB-16LNB-20LNB-25LNB-32LNB-40LNB-50LNB-63

L250L275L300L325L350L400

1/2” X 26 TPI M16 x 1.5

M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M63 x 1.52.5 BSP2.75 BSP3.0 BSP3.25 BSP3.5 BSP4.0 BSP

100100100100100402520666664

EN20AEN20BEN20CEN25AEN32AEN32B

403739424547

282831364246

181410886

Part Suits Cable Gland Inner Number Gland Across Carton Corners Protrusion Pack (mm) (mm) Quantity

Orange Shrouds

ACROSS FLATS

MOUNTING THREAD

MOU

NTIN

G TH

READ

DIAM

ETER

EART

H BO

LTDI

AMET

ER

CUT LINE FORMINIMUM CABLE

DIAMETER

SHROUDNUMBER

TO SUIT GLANDFROM SELECTION

CHART

PROTRUSION

EXTENSION NUT

ACRO

SS C

ORNE

RS

FLPW203B

FLPW206B

FLPW256B

FLPW326B

FLPW405B

FLPW503B

FLWN202FLWN203FLWN204FLWN205FLWN206FLWN253FLWN254FLWN255FLWN256FLWN323FLWN324FLWN325FLWN326FLWN403FLWN404FLWN405FLWN502FLWN503

WGN162WGN164WGN202WGN203WGN204

WGN206WGN254WGN256

WGN324WGN326

WGN403WGN404WGN405WGN502WGN503

S0-Orange

S1-Orange

S2-Orange

S3-Orange

S4-Orange

S5-Orange

S6-Orange

S7-Orange

UN20AUN20B

UN25A

UN32A

UN40A

UN40BUN50A

UN50BUN63A

UN63B

UFPN20AUFPN20B

UFPN20C

UFPN25A

UFPN32A

UFPN32B

UFPN40AUFPN40B

UFPN50AUFPN50B

UFPN63AUFPN63B

GN204GN206GN254GN256

GN324GN326

GN405

GN503GN505

GN636

Part Mounting Earth Inner Number Thread Bolt Carton Diameter Pack (mm) Quantity

Part Mounting Across Inner Number Thread Flats Carton Hexagon Pack (mm) Quantity

1620.727

31.640

48.257.38294102116116124140

150

140

110

90

70

50

40

18

9

Part Cable Gland Number UN UFPN GN WGN FLWN FLPWB Carton Pack Quantity

UFPN20AUFPN20BUFPN20CUFPN25AUFPN32AUFPN32B

Page 11: Cable Gland

Nicote Accessories

UB4PUB8P

UB13P

UB17PUB22P

UB27P

UB31P

UB36PUB41P

UB45P

UB117P

UB118PUB119P

UB517P

UB518P

WGN162WGN164WGN202WGN203WGN204WGN206

WGN254WGN256

WGN324WGN326

WGN403WGN404WGN405

WGN502WGN503WGN504WGN505WGN634WGN635WGN636

WGN753WGN754WGN755

WGN10AWGN10B

1/2”M16

M20

M20M25

M32

M40

M50M50

M63

2.5” BSP

2.75” BSP3” BSP

3.5” BSP

4” BSP

UN12AUN16A

UN20A

UN20BUN25A

UN32A

UN40AUN40B

UN50AUN50B

UN63AUN63B

FLWN202FLWN203FLWN204FLWN205FLWN206

FLWN253FLWN254FLWN255FLWN256FLWN323FLWN324FLWN325FLWN326FLWN403FLWN404FLWN405

FLWN502FLWN503FLWN504FLWN505FLWN633FLWN634FLWN635FLWN636FLWN753FLWN754FLWN755

UFPN20AUFPN20BUFPN20C

UFPN25A

UFPN32AUFPN32B

UFPN40AUFPN40B

UFPN50AUFPN50B

UFPN63AUFPN63B

UFPN250A

UFPN275AUFPN300A

UFPN350AUFPN350BUFPN400AUFPN400B

FLPW203BFLPW206B

FLPW256B

FLPW326B

FLPW405B

FLPW503BFLPW505B

FLPW635BFLPW636B

FLPW754BFLPW755B

100100

100

100100

100

100

100100

20

20

2020

20

20

IP66/68 GASKETAs supplied with glands

Fibre Gasket

Part Mounting Cable Gland Number Thread UN UFPN WGN FLWN FLPWB Carton Size Pack Quantity

10

Page 12: Cable Gland

ApplicationsIndoor and outdoor use in harsh environments

StandardsAS 1939 - 1990

FunctionProvides seal on cable sheath

Protection ClassIP65

ConstructionBody and compression nut316 Stainless Steel

SSG Cable GlandGENERAL PURPOSE STAINLESS STEEL CABLE GLANDS

Thomas & Betts Stainless Steel Cable

Glands are high quality glands designed

for use in severe environments. Made

from 316 grade stainless steel, each

gland features a wide cable diameter

range and UP65 protection.

8.411.516.321

27.7

3.56.4111519

M16x1.5M20x1.5M20x1.5M25x1.5M32x1.5

Part Mounting Cable Acceptance Number Thread Details Across Pack Size Length Overall Diameter Corners Qty (mm) (mm) Min (mm) Max (mm) (mm)

SSG-16-8SSG-20-11SSG-20-16

SSG-25SSG-32

1010121212

5025252510

2222

27.53240

Part Mounting Cable Acceptance Number Thread Details Across Pack Size Length Overall Diameter Corners Qty (mm) (mm) Min (mm) Max (mm) (mm)

SCG-20-10SSG-20-13

M20x1.5M20x1.5

1010

6.510

1013.5

2228

2525

ApplicationsIndoor and outdoor use with EMCscreened cables

FunctionProvides seal on cable sheathand earthing of screen

Protection ClassIP65

ConstructionBody and compression nutNickel plated brass,

EMC Cable GlandCABLE GLAND FOR EMC SCREENED CABLE

Thomas & Betts EMC Cable Glands are

high quality glands designed for use with

EMC screened cables using a garter spring

to earth the screen. EMC glands can also

be used with Belden Armoured Cables.

MOU

NTIN

G TH

READ

ACRO

SS C

ORNE

RS

CABL

E OV

ERAL

L

MAX

BODY

SEAL

SKID WASHER

NUT

PROTRUSIONTHREADLENGTH

GARTER SPRING

SCREEN EXPOSED

COMPRESSION RINGSSEAL

NUT

PROTRUSION

BODY

MOU

NTIN

G TH

READ

CABL

E OV

ERAL

LM

AX

ACRO

SS C

ORNE

RS

SKID WASHER

THREADLENGTH

Prod

uct

spec

ifi ca

tions

may

cha

nge

at a

ny t

ime

with

out

notic

e.

Prod

uct

spec

ifi ca

tions

may

cha

nge

at a

ny t

ime

with

out

notic

e.

Fitting Instructions1. Screw the gland body into the apparatus.2. Measure the length of tails required and add about 15 mm to this point.3. Strip the outer sheath.4. Cut the screen so that approx 15mm is exposed.5. Pass the cable through the gland and ensure that the exposed screen aligns with the garter spring.5. Tighten gland nut so that the seal grips fi rmly onto the cable.

11

Page 13: Cable Gland

For further information on Thomas & Betts products and services Phone 1300 666 595 Fax 1300 666 594 www.tnbaust.com

Thomas & Betts Australasia Pty Ltd Head Offi ce & Manufacturing 23A Nyrang Street, Lidcombe, NSW 2141

ABN 62 074 810 898