a Nexans company
Catalogue 2006
WWW.CABLEJOINTS.CO.UKTHORNE & DERRICK UK
TEL 0044 191 490 1547 FAX 0044 477 5371TEL 0044 117 977 4647 FAX 0044 977 5582
WWW.THORNEANDDERRICK.CO.UK
1
EUROMOLDCOMPANY PRESENTATION
While every care is taken to ensure that the information containedin this publication is correct, no legal responsibility can be accepted
for any inaccuracy. EUROMOLD NV reserves the right to alter ormodify the characteristics of its products described in this catalogue
as standards and technology evolve.
EUROMOLDEuromold is the leadingEuropean specialised designer,manufacturer and distributor ofprefabricated cable accessoriesfor medium voltage energydistribution. Euromold providesa complete range of acces-sories for underground cables:pre-moulded EPDM or siliconerubber connectors, terminationsand joints for cables and epoxybushings for transformers andswitch gear, as well as a largerange of cold-shrinkableterminations and joints from 12to 42 kV.Euromold is also the manufac-turer of electrical componentsfor the high voltage accessoriesof the Nexans group.
ISO 9001 CertificateSince 1992, Euromold’scommitment to quality isdemonstrated by its ISO 9001certification.
Laboratory accreditationSince June 2000, Euromold’sindependent ELAB laboratoryobtained the BELTEST accredi-tation no.192-T-ISO 17025conform with the Europeanstandards for laboratories ISO17025 for electrical testing ofmedium voltage cable acces-sories according to the Inter-national standards IEC 61442and HD 629.
International standardsAll our products meet theInternational standards likeCENELEC HD 629.1, CENELECEN 50180, IEC 137, IEEE 386& 404… or country specifica-tions. Official certificates, CESI,KEMA, ATEX… prove the con-formity of our products. Longduration tests of existing ornew products are continuouslyperformed in our test fields.
2
SEPARABLE CONNECTORSAND BUSHINGS
INTERFACE C
Table of contents400LB - elbow connector430TB-630A - tee connector400TB - tee connector440TB - tee connector300PB-630A - coupling connector400AR-3 - equipment bushing400A-24B - in-air bushing400PB-XSA - surge arrester400TR & 400TR-LB - test rodAccessoriesPossible arrangementsFixings for equipment bushings400TK-400SW installation tools
Interface CDimensions according toEuropean CENELEC EN501810 and 50181 (in mm).
M16 x 2 - 6H
11 min.
Dia. 56± 0,2
Dia. 46± 0,2
Dia. 22min.
1,5 0- 0,5
29min.
90± 0,2
Dia. 70± 0,2
3
Connecting possibilities
BUSHINGS /ACCESSORIES
CONNECTION CONNECTORS /ACCESSORIES
cableearthing
tap-off630/250A
cable
isolation
in-linejunction
one cable toequipment
dead-endingof equipment (K)(M)400DR-B
Dead-end receptacle
in-linejunction
(K)430TB-630ATee connector
(K)400LBElbow connector
(K)(M)(P)400TB/GTee connector
(K)(M)440TB/GTee connector
Equipmentinterface
400GP-BEarthing plug
(K)400RTPAReducing tap plug
(K)(M)400SOP-BStand-off plug
(K)(M)440CPConnecting plug
(K)(M)400AR-3Equipment bushing
400A-24BIn-air bushing
(K)(M)400CP-SCConnecting plug
4
Specifications andstandardsThe separable connector 400LBmeets the requirements ofCENELEC HD 629.1.
Up to 24 kV - 630 A
Separableconnector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor size (mm2)
min. max.
400LBK400LB
1224
630630
2525
300300
DesignSeparable connectorcomprising:1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer
moulded between the insertand the jacket.
4. Type C - 630 A interfaceas described by CENELECEN 50180 and 50181.
5. Conductor connector (notincluded in the standard kit).
6. Insulating plug.7. Cable reducer.8. Earth lead.9. Transition contact M10/M16.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
400LBINTERFACE C
ELBOW CONNECTOR
ApplicationSeparable elbow connectordesigned to connect polymericinsulated cable to equipment(transformers, switch gear,motors...).Also connects cable to cable,using the appropriate matingpart.
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
Technical characteristics• The thick conductive EPDM
jacket provides a total safe totouch screen which ensuressafety for personnel.
• Each separable connector istested for AC withstand andpartial discharge prior toleaving the factory.
205 mm
370 mm
3
2
1
45
8
7
69
5
Kit contentsThe complete (K)400LB elbowconnector kit comprises 3 x thefollowing components:
The kit also comprises lubricant, wipers,installation instructions and crimp chart.
Ordering instructionsSelect the part numberwhich gives the best centringto the cable core insulationdiameter.Add a 'K' for use up to 24 kV.
For conductors 240 and300 mm²:We automatically supply theconductor compression lugs for240 and 300 mm² aluminiumconductors and 300 mm²copper conductors.
Orderingpart number
Dia. over core insulation (mm)
min. max.
3 x 400LB-113 x 400LB-153 x 400LB-193 x 400LB-22
3 x 400LB-25(-X)3 x 400LB-27(-X)
12.016.020.023.526.528.5
17.522.026.531.032.537.5
Example:The copper wire screenedcables are 24 kV, 240 mm2
stranded aluminium with adiameter over core insulationof 32.2 mm.Order 3 x K400LB-27-240(K)M-12-2 elbow connector kit.
For use withother cable types.
Please contact ourrepresentative.
For outdoorapplications.
Order: +MWS.
Components can beordered individually.
Conductorsize
(mm2)
Aluminium conductor Copper conductor
DIN hexagonal DIN hexagonal
240300
240(K)M-12-2300(K)M-12-2
-300(K)M-11-2
Table X
For use withcopper tape
screened cables.Order: Kit MT.
For use with Alupe orC 33-226 cables.
Please contact ourrepresentative.
For use with fabric tape(graphite) screened cables.
Order additionalsemi-conductive tape
(type TSC).
+ + +
Connector housing(K)400BLB
Transitioncontact +
screw assembly400LTS
Compressionlug (optional)
400LBC-X
Insulatingplug
400LBP
+
Cable reducer411CA-W
= 3 x (K)400LB-W(-X)connector kit
Table W
Notes for conductors from 25up to 185 mm²:We do not supply the compressionlugs for cables from 25 up to 185mm². All types of cable lugs canbe used. The lugs must be withinthe dimensions specified.112 max.
135 max.
38max.
Dia. 36max.
2 max.
Dia. 10.2 or 13
10max.
24 max.
6
ApplicationSeparable tee shapeconnector (bolted type)designed to connect polymericinsulated cable to equipment(transformers, switch gear,motors, ...).Also connects cable to cablewhen using the appropriatemating parts.
Technical characteristics• A thick conductive EPDM
jacket provides a total safe totouch screen.
• Each separable connector istested for AC withstand andpartial discharge prior toleaving the factory.
Specifications andstandardsThe separable connector430TB-630A meets therequirements of CENELEC HD629.1.
Up to 24 kV - 630 A
Separableconnector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor size (mm2)
min. max.430TB-630A
K430TB-630A1224
630630
3535
300300
Design1. Type C - 630 A interface
as described by CENELECEN 50180 and 50181.
2. Clamping screw.3. Conductive EPDM insert.4. Insulating EPDM layer
moulded between theinsert and the jacket.
5. Conductive EPDM jacket.6. Conductive rubber cap.7. Basic insulating plug
(standard version withoutvoltage detection point).
8. Conductor connector9. Cable reducer.
10. Earthing lead.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
430TB-630AINTERFACE C
TEE CONNECTOR
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
183 mm
Non-size sensitive:290 mm
Size sensitive:350 mm
3
4
5
7
6
8
9
2
1
10
7
Kit contentsThe complete (K)430TB-630Atee connector kit comprises 3 xthe following components:
The kit also comprises lubricant, wipers,water sealing mastic, installation rod,installation instructions and crimp chart.
Ordering instructionsTo order the tee connector, usethe tables beside to substitutefor W1/W2 and X in theformulas.
1. From table W1 or W2:select the symbol whichgives the best centringof your core insulationdiameter.
2. From table X: accordingto your conductor size andtype, select the designationwhich completes the partnumber.
Example:The cable is 24 kV, 150 mm2
compact stranded copper witha diameter over core insulationof 27.5 mm.Order 3 x K430TB-18-95.240-14-5 for a non-size sensitiveapplication or 3 x K430TB-22-150(K)M-11-2 for a sizesensitive application.
Clampingscrew
430TCS
Basic insu-lating plug+ rubber
cap 300BIPRConnector housing
430BT-630A
Cable reducer430CA-W1
Cable reducer411CA-W2
Conductorcontact TMBC-X
Conductorcontact TBC-X
+ + +
+
+
= 3 x (K)430TB-W1-Xconnector kit fornon-size sensitive
application
3 x (K)430TB-W2-Xconnector kit for
size sensitiveapplication
=
non-sizesensitive
sizesensitive
Table W1 Table W2
Dia. over coreinsulation (mm) W1
min. max.
19.0 32.6 18
Dia. over coreinsulation (mm) W2
min. max.
12.016.020.023.526.528.5
17.522.026.531.032.537.5
111519222527
For use witheasy strip semi-conductivescreened cables. Order:
Field control mastic(type MFC).
Basic insulating plug alsoavailable with a voltage
detection point.Order : - /VD.
Table X
Conduc-tor size(mm2)
Aluminium conductor Copper conductor
DINhexagonal
Deepindent
BoltedDIN
hexagonalBolted
35507095120150185240300
35(K)M-10-250(K)M-10-270(K)M-10-295(K)M-10-2
120(K)M-10-2150(K)M-10-2185(K)M-10-2240(K)M-10-2300(K)M-10-2
35(K)M-10-150(K)M-10-170(K)M-10-195(K)M-10-1120(K)M-10-1150(K)M-10-1185(K)M-10-1240(K)M-10-1
–
–35(K)M-11-250(K)M-11-270(K)M-11-295(K)M-11-2120(K)M-11-2150(K)M-11-2185(K)M-11-2240(K)M-11-2300(K)M-11-2
–
95.240-14-5 95.240-14-5
– –
For use withother cable types.
Please contact ourrepresentative.
For outdoorapplications.
Order: +MWS.
For use withcopper tape
screened cables.Order: Kit MT.
For use with Alupe orC 33-226 cables.
Please contact ourrepresentative.
VoltageUm (kV) Non-size sensitive Size sensitive
1224
3 x 430TB-W1-X3 x K430TB-W1-X
3 x 430TB-W2-X3 x K430TB-W2-X
8
Up to 41.5 kV - 630 A
400TBINTERFACE C
TEE CONNECTOR
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
18/30 (36) kV19/33 (36) kV
20.8/36 (41.5) kV
Technical characteristics• The thick conductive EPDM
jacket provides a total safe totouch screen which ensuressafety for personnel.
• Each separable connector istested for AC withstand andpartial discharge prior toleaving the factory.
Separableconnector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor size (mm2)
min. max.
400TB/GK400TB/GM400TB/GP400TB/G
122436
41.5
630630630630
35353535
300300240240
ApplicationSeparable tee shapeconnector (bolted type)designed to connect polymericinsulated cable to equipment(transformers, switch gear,motors, ...).Also connects cable to cablewhen using the appropriatemating parts.
DesignSeparable connectorcomprising:
1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer.4. Type C - 630 A interface
as described by CENELECEN 50180 and 50181.
5. Conductor connector.6. Basic insulating plug (with
VD point).7. Cable reducer.8. Conductive rubber cap.9. Clamping screw.
10. Earthing lead.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
Specifications andstandardsThe separable connector 400TBmeets the requirements ofCENELEC HD 629.1 S1.
255 mm220 mm
390 mm
3
2
1
4
56
7
8
10
9
9
For use withother cable types.
Please contact ourrepresentative.
For outdoorapplications.
Order: +MWS.
Components can beordered individually.
For use withcopper tape
screened cables.Order: Kit MT.
For use with Alupe orC 33-226 cables.
Please contact ourrepresentative.
For use in potentiallyexplosive atmospheres
(for 12 kV max.).Order: -/ATEX.
Kit contentsThe complete (K)(M)(P)400TB/Gtee connector kit comprises thefollowing components:
The kit also comprises lubricant, wipers,installation instructions and crimp chart.
Ordering instructionsTo order the tee connector,select the ordering part numberwhich gives you the bestcentring of your core insula-tion diameter and substitute Xusing table X, according to yourconductor size and type.Add a 'K' for use up to 24 kV,an 'M' for use up to 36 kV oradd a 'P' for use up to41.5 kV.
Orderingpart number
Dia. over core insulation (mm)
min. max.
400TB/G-11-X400TB/G-15-X400TB/G-19-X400TB/G-22-X400TB/G-25-X400TB/G-27-X
12.016.020.023.526.528.5
17.522.026.531.032.537.5
Example:The copper wire screened cableis 36 kV, 150 mm2 strandedcopper with a diameter overcore insulation of 32.5 mm.Order a M400TB/G-27-150(K)M-11-2 tee connector kit.
Connector housing(K)(M)(P)400BT/G
Clampingscrew
400TCS
ConductorcontactTBC-X
Basic insulatingplug +
rubber cap(K)(M)(P)400BIPA
Cable reducer411CA-W
(K)(M)(P)400TB/G-W-Xconnector kit
Table W
Table X
Conductor size(mm2)
Aluminium conductor Copper conductor
DINhexagonal
Deepindent
DINhexagonal
35507095120150185240300
35(K)M-12-250(K)M-12-270(K)M-12-295(K)M-12-2
120(K)M-12-2150(K)M-12-2185(K)M-12-2240(K)M-12-2300(K)M-12-2
35KM-12-150KM-12-170KM-12-195KM-12-1120KM-12-1150KM-12-1185KM-12-1240KM-12-1300KM-12-1
35(K)M-11-250(K)M-11-270(K)M-11-295(K)M-11-2
120(K)M-11-2150(K)M-11-2185(K)M-11-2240(K)M-11-2300(K)M-11-2
+ + + + =
10
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
18/30 (36) kV
Up to 36 kV - 630 A
440TBINTERFACE C
TEE CONNECTOR
Technical characteristics• The thick conductive EPDM
jacket provides a total safe totouch screen which ensuressafety for personnel.
• Each separable connector istested for AC withstand andpartial discharge prior toleaving the factory.
ApplicationSeparable tee shapeconnector (bolted type)designed to connect polymericinsulated cable to equipment(transformers, switch gear,motors, ...).Also connects cable to cablewhen using the appropriatemating parts.
DesignSeparable connectorcomprising:
1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer
moulded between the insertand the jacket.
4. Type C - 630 A interfaceas described by CENELECEN 50180 and 50181.
5. Conductor connector.6. Basic insulating plug (with
VD point).7. Cable reducer.8. Conductive rubber cap.9. Clamping screw.
10. Earthing lead.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
Specifications andstandardsThe separable connector 440TBmeets the requirements ofCENELEC HD 629.1.
Separableconnector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor size (mm2)
min. max.440TB/GK440TB/GM400TB/G
122436
630630630
185185185
630630630
400 mm
3
2
1
4
5
7
6 8
10
9
255 mm220 mm
11
Kit contentsThe complete (K)(M)440TB/Gtee connector kit comprises thefollowing components:
The kit also comprises lubricant, wipers,installation instructions and crimp chart.
Ordering instructionsTo order the tee connector,select the ordering part numberwhich gives you the bestcentring of your core insula-tion diameter and substitute Xusing table X, according to yourconductor size and type.Add a 'K' for use up to 24 kVand add an 'M' for use up to36 kV.
Orderingpart number
Dia. over core insulation (mm)
min. max.
440TB/G-22-X440TB/G-27-X440TB/G-32-X440TB/G-37-X440TB/G-43-X
23.528.534.039.045.5
31.037.542.548.556.0
Example:The copper wire screened cableis 36 kV, 240 mm2 strandedaluminium with a diameter overcore insulation of 37.0 mm.Order a M440TB/G-32-240(K)M-12-2 tee connector kit.
When installed on anappropriate equipment
bushing:1250 A continuously
For use withcopper tape
screened cables.Order: Kit MT.
+ + +
Connector housing(K)(M)440BT/G
Clampingscrew
400TCS
ConductorcontactTBC-X
Basicinsulating
plug +rubber cap
(K)(M)400BIPA
+
Cable reducer611CA-W
= (K)(M)440TB/G-W-Xconnector kit
Table W
Table X
Conductor size(mm2)
Aluminium conductor Copper conductor
DINhexagonal
Deepindent
DINhexagonal
185240300400500630
185(K)M-12-2240(K)M-12-2300(K)M-12-2400(K)M-12-2500(K)M-12-2
–
185KM-12-1240KM-12-1300KM-12-1400KM-12-1500KM-12-1630KM-12-1
185(K)M-11-2240(K)M-11-2300(K)M-11-2400(K)M-11-2500(K)M-11-2630(K)M-11-2
For use withother cable types.
Please contact ourrepresentative.
For outdoorapplications.
Order: +MWS.
Components can beordered individually.
For use in potentiallyexplosive atmospheres
(for 12 kV max.).Order: -/ATEX.
12
ApplicationSeparable coupling connector(bolted type) for dual cablearrangement. It has beendesigned to be used withseparable Tee connector430TB-630A.Total maximum current is630 A.
Technical characteristics• A thick conductive EPDM
jacket provides a total safe totouch screen.
• Each separable connector istested for AC withstand andpartial discharge prior toleaving the factory.
Specifications andstandardsThe 300PB-630A couplingconnector meets therequirements of CENELEC HD629.1 for 10 and 20 kV levels.
Up to 24 kV - 630 A
Design1. Interface designed to fit
430TB-630A connector.2. Bus for 300PB.3. Conductive EPDM insert.4. Insulating EPDM layer
moulded between theinsert and the jacket.
5. Conductive EPDM jacket.6. Conductive EPDM cap.7. Basic insulating plug.8. Conductor connector
(hexagonal crimping, deepindent crimping or bolted).
9. Cable reducer.10. Clamping screw.11. Earth lead.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
300PB-630ACOUPLING CONNECTOR
FOR 430TB-630A
Separableconnector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor size (mm2)
min. max.300PB-630A
K300PB-630A1224
630630
3535
300300
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
3
2
1
4
5
7
8
10
9
Non-size sensitive:290 mm
Size sensitive:350 mm
105 mm
290 mm
11
6
13
Kit contentsThe complete (K)300PB-630Acoupling connector kitcomprises 3 x the followingcomponents:
The kit also comprises silicone grease,water sealing mastic, installation rod,installation instructions and crimp chart.
Ordering instructionsTo order the Tee connector, usethe tables beside to substitutefor W1/W2 and X in theformulas.
1. From table W1 or W2:select the symbol whichgives the best centringof your core insulationdiameter.
2. From table X: accordingto your conductor size andtype, select the designationwhich completes the partnumber.
Example:The cable is 24 kV, 150 mm2
compact stranded copper witha diameter over core insulationof 27.5 mm.Order 3 x K300PB-18-95.240-14-5 for a non-size sensitiveapplication or 3 x K300PB-22-150(K)M-11-2 for a sizesensitive application.
Clampingscrew
300PB-CS
Connector housing300BPB-630A
+
For use withcopper tape
screened cables.Order: Kit MT.
For use witheasy strip semi-conductivescreened cables. Order:
Field control mastic(type MFC).
For use with copperwire screened cables.
No earthingdevice is
necessary.
For use withother cable types.
Please contact ourrepresentative.
Table W1 Table W2
Table X
Dia. over coreinsulation (mm) W1
min. max.
19.0 32.6 18
Dia. over coreinsulation (mm) W2
min. max.
12.016.020.023.526.528.5
17.522.026.531.032.537.5
111519222527
Conduc-tor size(mm2)
Aluminium conductor Copper conductor
DINhexagonal
Deepindent Bolted
DINhexagonal Bolted
35507095120150185240300
35(K)M-10-250(K)M-10-270(K)M-10-295(K)M-10-2
120(K)M-10-2150(K)M-10-2185(K)M-10-2240(K)M-10-2300(K)M-10-2
35(K)M-10-150(K)M-10-170(K)M-10-195(K)M-10-1120(K)M-10-1150(K)M-10-1185(K)M-10-1240(K)M-10-1
–
–35(K)M-11-250(K)M-11-270(K)M-11-295(K)M-11-2120(K)M-11-2150(K)M-11-2185(K)M-11-2240(K)M-11-2300(K)M-11-2
–
95.240-14-5 95.240-14-5
– –
For outdoorapplications.
Order: +MWS.
Cable reducer430CA-W1
Cable reducer411CA-W2
Conductorcontact TMBC-X
Conductorcontact TBC-X
+
+
+
= 3 x (K)300PB-W1-Xconnector kit fornon-size sensitive
application
3 x (K)300PB-W2-Xconnector kit for
size sensitiveapplication
=
non-sizesensitive
sizesensitive
For use with fabric tape(graphite) screened cables.
Order additionalsemi-conductive tape
(type TSC).
VoltageUm (kV) Non-size sensitive Size sensitive
1224
3 x 300PB-W1-X3 x K300PB-W1-X
3 x 300PB-W2-X3 x K300PB-W2-X
14
Up to 36 kV - 630 A
Equipmentbushing
type
VoltageUr
(kV)
CurrentIr
(A)
400AR-3K400AR-3M400AR-3
122436
630630630
400AR-3INTERFACE C
EQUIPMENT BUSHING
ApplicationFor use in equipment insulatedwith oil fluid, typically fortransformers, switch gear,capacitors...
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
18/30 (36) kV
Technical characteristicsEach bushing is tested forAC withstand and partialdischarge prior to leavingthe factory.
40
Dia. 128Dia. 88Dia. 70
M16
133
30
10
144
330
Minimum oil level:-12 kV: 40 mm-24 kV: 50 mm-36 kV: 70 mm
In mm.
DesignThe equipment bushing is amoulded epoxy insulated part inaccordance with CENELEC EN50180.
Specifications andstandardsThe bolted type equipmentbushings 400AR-3 meet therequirements of CENELEC EN50180 and IEC 137.
Ordering instructionsTo order the equipmentbushing, specify the type.The bushing are suppliedwith an earth lead (/J) or anearth plate (/GS). This earthconnection must be specifiedwhen ordering.E.g. M400AR-3/GS.For use in potentially explosiveatmospheres (for 12 kV max.).Order: -/ATEX.
15
400A-24BINTERFACE C
IN-AIR BUSHING
Up to 24 kV - 630 AApplicationFor use in equipmentinsulated with air, typicallyfor transformers, switch gear,capacitors...
Technical characteristicsEach bushing is tested forAC withstand and partialdischarge prior to leavingthe factory.
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
Equipmentbushing
type
VoltageUr
(kV)
CurrentIr
(A)
Creepage distanceA-B
(mm)
400A-24B400A-24B
1224
630630
500500
In mm.Dia. 80
20
434
250
30
40
M16
Dia. 80
Dia. 110A
B
Specifications andstandardsThe bolted type equipmentbushings 400A-24B meet therequirements of CENELEC EN50180 and IEC 137.
Ordering instructionsTo order the equipmentbushing, specify the type.The bushing are supplied withan earth lead.To include the ring clamp, add:• /B, if per British standards.• /D, if per German standards.• /F, if per French standards.E.g. 400A-24B/D.For use in potentially explosiveatmospheres (for 12 kV max.).Order: -/ATEX.
DesignThe equipment bushing is amoulded epoxy insulated part inaccordance with CENELEC EN50181.
16
FIXINGS FOREQUIPMENT BUSHINGS
INTERFACE C
400AR-3/J bushingDIN 42 538German standards.
fixing studs
bushing interface
sealing gasket
equipmentconnection
fixing flangeB DIN 42 538
E DIN 42 538clamp
equipment
earth jumper
55
M10
Dia. 140
Dia. 90
25
6 fixingstuds
In mm
17
400A-24B In-air bushing
Ffixing flange
BCA-F
10
Dia.12
Dia. 150
126
F
120°
120°
Type BCA-F : NFC 52-053 French standards
4Dia. 94.5
Dia. 111
equipmentconnection
bushing interface
fixing studs andnuts M10
earth jumper
equipment
gasket
fixing flangeBCA-B orBCA-D
BS 2562 stand.: 120DIN 42 538 stand.: 123
Dia. 94.5
Dia. 111
10
Dia.12
Type BCA-B : BS 2562 British standards
Type BCA-D : DIN 42 538 German standards
4
Dia. 150
M10
Dia. 123
Dia. 82
5525
Dia. 126
5227
M8 orM10
4 fixingstuds
3 fixingstuds
Dia. 82
In mm
18
Surgearrester
type
Nominaldischarge
currentIn (kA)
Ratedvoltage
Ur(kV)
Max. continuousoperatingvoltageUc (kV)
Steep currentresidual
voltage @ 5 kA[1/20 µs] (kV)
Lightning currentresidual
voltage @ 5 kA[8/20 µs] (kV)
High currentimpulse
withstand(kA)
Dimensions(mm)
L1 L2
400PB-5SA-15L400PB-5SA-18L400PB-5SA-22L400PB-5SA-24L400PB-5SA-30L
400PB-10SA-15N400PB-10SA-18N400PB-10SA-22N400PB-10SA-24N400PB-10SA-30N400PB-10SA-36N400PB-10SA-45N
5555510101010101010
151822243015182224303645
12.014.417.619.224.012.014.017.619.224.028.836.0
42.452.765.770.087.346.256.068.974.492.7111.1138.2
40.048.059.064.080.040.248.659.864.580.496.4120.0
6565656565100100100100100100100
250250350350350250250350350350350450
290290390390390290290390390390390490
DesignSurge arrester comprising:1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer
moulded between the insertand the jacket.
4. Contact rod.5. Earth lead.6. Earth connection.7. Steel cap.8. Metal oxide valve elements.9. Type C - 630 A interface
as described by CENELECEN 50180 and 50181.
6
9
5
4
3
2
1
252 mm
L2L1
150 mm
Dia.80 mm
7
Dia.70 mm
8
ApplicationSurge arrester designed toprotect 12 and 24 kV classcomponents, includingtransformers, equipment, cableand accessories from highvoltage surges resulting fromlightning or switching.
Up to 36 kV
400PB-XSAINTERFACE C
SURGE ARRESTER
6/10 (12) kV6.35/11 (12) kV
8.7/15 (17.5) kV12/20 (24) kV
12.7/22 (24) kV18/30 (36) kV
Technical characteristics• This surge arrester is a metal
oxide varistor surge arrester inan elbow configuration.
• Each arrester is tested forAC withstand and partialdischarge prior to leaving thefactory.
19
Typical application anddimensions
Ordering instructionsTo order the surge arrester,specify the surge arrester type,as described on previous page.
Example:For a maximum continuousoperating voltage (rms) of24 kV and a nominal dischargecurrent of 10 kA.Order a 400PB-10SA-24Nsurge arrester.
410 mm
220 mm 185 mm
Type 400PB-5SAor 400PB-10SAsurge arrester
Type 400TB/Gor K400TB/Gtee connector
355 mm
150 mm 202 mm
Type 400LBor K400LB
elbow connector
Type 400PB-5SAor 400PB-10SAsurge arrester
335 mm
150 mm 183 mm
Type 430TBor K430TBtee connector
Type 400PB-5SAor 400PB-10SAsurge arrester
20
Application• The test rod can be used for:
- cable fault location- cable testing- phasing checks, etc.
• Connections may be madewith a cable lug, a 4 mmplug or spring clips.
Test rodtype
Maximum A.C.test voltage
(50 Hz - 1 min.)
Maximum D.C.test voltage
(8 x U0 - 30 min.)
Impulse voltage(1.2 x 50 µs)
min.
400TR400TR-LB
36 kV36 kV
96 kV96 kV
95 kV95 kV
Technical characteristics• The 400TR test rod can
be used with 400TE,430TB, 400TB and 440TBconnectors.
• The 400TR-LB is for use withthe 400LB connector.
480
4
5
2
288
40
1
3
M12
In mm.
400TR 400TR-LB
370
60
1
5
6
2
Dia.25
M10
4
InstallationThe test rod is mounted onto the clamping screw inthe type C interface tee andcoupling connectors. Thetest cable is connected tothe threaded stem and theinsulating shroud moved to itsfinal position over the end ofthe test rod.
Design1. Insulating shroud.2. Threaded rod for test
connection.3. Two nuts M12.4. Insulation.5. Copper test rod stem.6. Wing nut.
An insulating shroud isprovided to allow theapplication of test voltageswhen bushings are closelyspaced.
Ordering instructionsSimply specify:400TR or 400TR-LB test rod.
400TR and 400TR-LBINTERFACE C
TEST RODS
21
400TK & 400SWINSTALLATION TOOL
Application• The box spanner and box
spanner key are designedto facilitate assembly of400TE, 400TB and 440TBconnectors.
• The 400TK box spanner isused to install the 400TEFclamping pin contact or400TCS clamping screw.
Ordering instructionsSimply specify:- 400TK box spanner- 400SW box spanner key
• The 400SW box spannerkey fits on the hex nut of the400BIPA basic insulatingplug.
400TK
400SW
22
ACCESSORIESINTERFACE C
Up to 36 kVApplicationFor use with connectors andbushings with an interface Cas described by CENELEC EN50180 and 50181.
Technical characteristicsAll these products, except theearthing plugs, are tested forAC withstand and partialdischarge prior to leavingthe factory.
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
18/30 (36) kV
400SOP-BStand-off plugIs designed to support and'dead-end' connectors with atype C interface when removedfrom equipment.
Ordering instructionsOrder400SOP-B for 12 kV,K400SOP-B for 24 kV orM400SOP-B for 36 kVapplications.
400GP-BEarthing plugIs designed to support andearth connectors with a type Cinterface when removed fromequipment.
Ordering instructionsOrder400GP-B for 12, 24 or 36 kVapplications.
300GP-BEarthing plugIs designed to earth the 430TB-630A connectors when it isfixed-mounted to the equipment(maintenance earthing).
Ordering instructionsOrder300GP-B for 12 or 24 kVapplications.
400DR-BDead-end receptacleFits over a bushing with a typeC interface to provide 'dead-end' facility.
Ordering instructionsOrder400DR-B for 12 kV,K400DR-B for 24 kV orM400DR-B for 36 kVapplications.The dead-end receptacle canbe supplied with an earth lead.Order: -/G.E.g. K400DR-B/G.
23
Kit MTEarthing kit for coppertape screened cablesContains a tinned copper braid(25 mm² - L = 500 mm), atinned copper wire for cleatingand some water sealing mastic.
Ordering instructionsOrderKit MT for 12 kV, 24 kV36 kV or 41.5 kV applications.
440CPConnecting plugFor connecting two or more440TB connectors, thus creatinga separable cable joint or amultiple cable connection toequipment.For use up to 1250 A.Only for use with 440TB.
400RTPAReducing tap plugProvides a type A interfaceto connectors with a type Cinterface.A 'C' spanner, 600SW, is usedto tighten the reducing tap plugon to its mating part.
Ordering instructionsOrder400RTPA for 12 kV orK400RTPA for 24 applications.Order 600SW for the 'C'spanner.
400CP-SCConnecting plugFor connecting two or moreconnectors with a type Cinterface together, thus creatinga separable cable joint or amultiple cable connection toequipment.
Ordering instructionsOrder400CP-SC for 12 kV,K400CP-SC for 24 kV orM400CP-SC for 36 kVapplications.
400BIPABasic insulating plugActs as a tightening nut forthe 400TB and 440TB teeconnector kits.The plug contains a voltagedetection point.The conductive rubberprotection cap is included.
Ordering instructionsOrder400BIPA for 12 kV,K400BIPA for 24 kV orM400BIPA for 36 kVapplications.
Ordering instructionsOrder440CP for 12 kV,K440CP for 24 kV orM440CP for 36 kVapplications.Order: -/ATEX for use inpotentially explosiveatmospheres (for 12 kV max.).
24
POSSIBLE ARRANGEMENTSINTERFACE C
430TBSingle cable arrangement.Order 430TB for 12 kV orK430TB for 24 kV applications.
430TB+300PBDual cable arrangement.Order 430TB+300PB for 12 kVor K430TB+K300PB for 24 kVapplications.
400TB/GSingle cable arrangement.Order 400TB/G for 12 kV,K400TB/G for 24 kV,M400TB/G for 36 kV orP400TB/G for 41.5 kVapplications.
In mm.
183
110
teeconnector
basicinsulatingplug
250
110
teeconnector
basicinsulatingplug
290
110 105
teeconnector
couplingconnector
basicinsulatingplug
400TB/G-P2Dual cable arrangement.Order 400TB/G-P2 for 12 kV,K400TB/G-P2 for 24 kV orM400TB/G-P2 for 36 kVapplications.
connectingplug
500
110 245
basicinsulating
plug
25
In mm.
400TB/G-L4Disconnectable tap-off.Order 400TB/G-L4 for 12 kV,K400TB/G-L4 for 24 kV orM400TB/G-L4 for 36 kVapplications.
1020
basicinsulating
plug
connectingplug
connectingplugs
basicinsulating
plug
400TB/G-L22-way connection.Order 400TB/G-L2 for 12 kV,K400TB/G-L2 for 24 kV orM400TB/G-L2 for 36 kVapplications.
400TB/G-L52-way connection with tap-off.Order 400TB/G-L5 for 12 kVor K400TB/G-L5 for 24 kVapplications.
connecting plug
530
basicinsulating
plug
basicinsulating
plug
505
type Aseparableconnector
reducingtap plugbasic
insulatingplug
400TB/G-L33-way connection.Order 400TB/G-L3 for 12 kV,K400TB/G-L3 for 24 kV orM400TB/G-L3 for 36 kVapplications.
775
basicinsulating
plug
basicinsulating
plug
connectingplug
connectingplug
26
Connector on earthingplugOrder 400GP-B for 12 kV,24 kV and 36 kV applications.
earthingplug
basicinsulating
plug
Earthing plug onconnectorOrder 300GP-B for 12 kV and24 kV applications.
430TB teeconnector
300GPBearthing plug
Connector on stand-offplugOrder 400SOP-B for 12 kV,K400SOP-B for 24 kV orM400SOP-B for 36 kVapplications.
stand-offplug
basicinsulating
plug
27
In mm.
110
600
insulatingshroud
400TRtest rod
400TB or 440TBtee connector
110
430TB teeconnector
600
insulatingshroud
400TRtest rod
Cable and equipmenttesting.
125
400LB elbowconnector
515
insulatingshroud
400TR-LBtest rod
28