Cable Block Diagram

1
MAIN PLANT DCS FO-TYPE SPL-TYPE LOCAL RELAY BASED CONTROL PANEL / PLC / SCADA F/G/CC/PC/TYPE F/G - TYPE F/G - TYPE F/G - TYPE F - TYPE F/G - TYPE F - TYPE G - TYPE G - TYPE G - TYPE VMS PANEL PC - TYPE F/G/SPL - TYPE (24V DC) JB/ LIE / LIR JUNCTION BOX MCC SWGR CC - TYPE PC - TYPE CC - TYPE PC - TYPE EPB LT DRIVE EPB HT DRIVE WDG/BRG RTDs IJB MODULATING DRIVE BI- DIRECTIONAL DRIVE MCC (FOR INCHING TYPE) PC - TYPE VIBRATION SENSORS FIELD INSTRUMENT INTEGRAL TYPE SOV IPR PANEL CC - TYPE CENTRAL CENTROL ROOM LOCAL CONTROL ROOM MCC / SWGR ROOM FIELD F/G TYPE SPL - TYPE PC - TYPE UPS F - Analog Signal (Individual & Over all sheild) - Instrumentation Cable (2P/4P/6P/8P/12P/16P/24P) G - Binary Signal (Over all sheild) - Instrumentation Cable (2P/4P/6P/8P/12P/16P/24P) CC - Control Cable PC - Power Cable SPL - Special Cable FO - Fibre Optic Cable Cable Type:- LEGEND MOD LTUD HTUD DCS PLC MCC SWGR LPBS SOV JBD JB IPR LIE LIR - MODULATING DRIVE PNEUMATIC OPERATED - LOW TENSION UNI-DIRECTIONAL DRIVE - HIGH TENSION UNI-DIRECTIONAL DRIVE - DISTRIBUTED CONTROL SYSTEM - PROGRAMMABLE LOGIC CONTROLLER - MOTOR CONTROL CENTRE - SWITCHGEAR - LOCAL PUSHBUTTON STATION - SOLENOID VALVE - JUNCTION BOX DIGITAL - JUNCTION BOX - INTERPOSING RELAY - LOCAL INSTRUMENT ENCLOSURE - LOCAL INSTRUMENT RACK

Transcript of Cable Block Diagram

Page 1: Cable Block Diagram

MAIN PLANT DCS

FO-T

YP

E

SP

L-TY

PE

LOCAL RELAY BASED CONTROL PANEL / PLC / SCADA

F/G

/CC

/PC

/TY

PE

F/G

- TY

PE

F/G

- TY

PE

F/G

- TY

PE

F - T

YP

E

F/G

- TY

PE

F - T

YP

E

G -

TYP

E

G -

TYP

E

G -

TYP

E

VMSPANEL

PC

- TY

PE

F/G

/SP

L - T

YP

E

(24V DC)

JB/LIE / LIR

JUNCTIONBOX

MCC SWGR

CC

- TY

PE

PC

- TY

PE

CC

- TY

PE

PC

- TY

PE

EPB

LT DRIVE

EPB

HT DRIVE

WDG/BRGRTDs

IJB

MODULATINGDRIVE

BI-DIRECTIONAL

DRIVE

MCC

(FO

R I

NC

HIN

G T

YP

E)

PC

- TY

PE

VIBRATIONSENSORS

FIELDINSTRUMENT

INTEGRAL TYPE

SOV

IPR PANEL

CC

- TY

PE

CE

NTR

AL

CE

NTR

OL

RO

OM

LOC

AL

CO

NTR

OL

RO

OM

MC

C /

SW

GR

RO

OM

FIE

LD F/G

TY

PE

SP

L - T

YP

E

PC - TYPE UPS

F - Analog Signal (Individual & Over all sheild)- Instrumentation Cable(2P/4P/6P/8P/12P/16P/24P)

G - Binary Signal (Over all sheild)- Instrumentation Cable(2P/4P/6P/8P/12P/16P/24P)

CC - Control CablePC - Power CableSPL - Special CableFO - Fibre Optic Cable

Cable Type:-

LEGENDMODLTUDHTUDDCSPLCMCCSWGRLPBSSOVJBDJBIPRLIELIR

- MODULATING DRIVE PNEUMATIC OPERATED- LOW TENSION UNI-DIRECTIONAL DRIVE- HIGH TENSION UNI-DIRECTIONAL DRIVE- DISTRIBUTED CONTROL SYSTEM- PROGRAMMABLE LOGIC CONTROLLER- MOTOR CONTROL CENTRE- SWITCHGEAR- LOCAL PUSHBUTTON STATION- SOLENOID VALVE- JUNCTION BOX DIGITAL- JUNCTION BOX- INTERPOSING RELAY- LOCAL INSTRUMENT ENCLOSURE- LOCAL INSTRUMENT RACK