CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES....

8
2 VOLTEX CATALOGUE For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. 110 VOLTEX CATALOGUE LUGS AND FERRULES Copper Lugs for Stranded Conductor Cable Dimension 1. The nominal area of the circular stranded conductor is that of the nominal lug or ferrule size. 2. For flexible cables the next highest lug or ferrule size in relation to the area must be used. 3. For compacted cable the heavy duty lugs and ferrules must be used. Certain compacted cables vary in nominal diameter and cable diameter must be matched to the lug or ferrule barrel inside diameter. B A C D F E Nominal Lug Size Typical Conductors Stud Size Nominal Dimensions Product Code Circular Stranded Flexible Stranded (mm) Barrel Spade (mm 2 ) (mm) (mm 2 ) (mm) A B C D E F I.D O.D Length Length Hole Pos. Width 1,5 3/0,81 1 3 1,9 3,8 7,0 9,0 4,5 7,0 H10283 H964 - 4 12,0 4,5 7,0 H10284 H966 H2551 5 12,0 4,5 8,0 H10285 H967 H2552 6 13,0 5,5 9,0 H10286 H968 H2553 2,5 3/1,04 1,5 3 2,4 3,9 7,3 8,5 4,5 7,0 H10287 H969 - 4 12,0 4,5 7,0 H10288 H971 H2554 5 12,0 4,5 9,0 H10289 H972 H2555 6 13,0 5,5 9,5 H10290 H973 H2556 8 15,0 7,5 12,0 H10291 H975 H2557 4 7/0,86 2,5 3 2,8 4,7 9,0 4,5 7,0 H10292 H976 - 4 12,0 4,5 7,0 H10293 H977 H2559 5 8,0 12,0 4,5 8,5 H10294 H978 H2560 6 13,0 5,5 10,0 H10295 H979 H2561 8 17,0 6,5 13,0 H10296 H980 H2562 10 11,0 19,0 7,5 14,0 H10297 H981 H2563 6 7/1,05 4 4 3,4 5,3 12,0 4,5 7,5 H10298 H2857 H2564 5 12,0 4,5 8,5 H10299 H982 H2565 6 8,5 13,0 5,5 9,5 H10300 H983 H2566 8 9,3 17,0 7,0 13,0 H10301 H984 H2567 10 11,0 19,0 7,5 15,0 H10302 H985 - 10 7/1,36 6 5 10,5 12,0 4,5 9,0 H10303 H987 H2568 6 10,5 13,0 6,0 10,0 H10304 H988 H2569 8 4,4 6,3 11,0 17,0 7,5 13,0 H10305 H989 H2570 10 11,0 19,0 7,5 15,0 H10306 H990 H2571 12 12,0 20,0 10,0 19,0 H10307 H991 H2572 16 7/1,72 10 5 13,0 5,5 10,5 H10308 H993 H2574 6 13,0 5,5 11,0 H10309 H994 H2575 8 5,5 7,6 12,0 18,0 7,5 13,0 H10310 H995 H2576 10 20,0 7,5 15,0 H10311 H996 H2577 12 25,0 10,5 18,0 H10312 H997 H2578 16 27,0 13,0 24,0 H10313 H998 H2579 25 18/1,35 16 6 16,0 6,0 14,0 H10314 H999 H2581 8 17,0 8,0 14,0 H10315 H1000 H2582 19/1,55 10 6,9 9,0 15,0 18,0 8,0 16,0 H10316 H1001 H2583 12 21,0 11,0 18,0 H10475 H1002 H2584 16 27,0 13,0 24,0 H10317 H338 - Note: Indent compression recommended for flexible stranded. Confirm stock and brand availability with your local branch. Components are tested to IEC 61238-1. Items above with (-) in the codes column are available on special request. CABLE ACCESSORIES

Transcript of CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES....

Page 1: CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES. Copper Lugs for Stranded Conductor Cable. Dimension. 1.he nominal area of the circular

2 VOLTEX CATALOGUEFor extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.110 VOLTEX CATALOGUE

LUGS AND FERRULESCopper Lugs for Stranded Conductor Cable

Dimension1. The nominal area of the circular stranded

conductor is that of the nominal lug or ferrule size.2. For flexible cables the next highest lug or

ferrule size in relation to the area must be used.3. For compacted cable the heavy duty lugs and

ferrules must be used.

Certain compacted cables vary in nominal diameter and cable diameter must be matched to the lug or ferrule barrel inside diameter.

B A

C D

F

E

Nominal Lug Size

Typical Conductors

Stud Size

Nominal Dimensions Product Code

Circular Stranded

Flexible Stranded

(mm)

Barrel Spade

(mm2) (mm) (mm2) (mm)A B C D E F

I.D O.D Length Length Hole Pos. Width

1,5 3/0,81 1

3

1,9 3,8 7,0

9,0 4,5 7,0 H10283 H964 -

4 12,0 4,5 7,0 H10284 H966 H2551

5 12,0 4,5 8,0 H10285 H967 H2552

6 13,0 5,5 9,0 H10286 H968 H2553

2,5 3/1,04 1,5

3

2,4 3,9 7,3

8,5 4,5 7,0 H10287 H969 -

4 12,0 4,5 7,0 H10288 H971 H2554

5 12,0 4,5 9,0 H10289 H972 H2555

6 13,0 5,5 9,5 H10290 H973 H2556

8 15,0 7,5 12,0 H10291 H975 H2557

4 7/0,86 2,5

3

2,8 4,7

9,0 4,5 7,0 H10292 H976 -

4 12,0 4,5 7,0 H10293 H977 H2559

5 8,0 12,0 4,5 8,5 H10294 H978 H2560

6 13,0 5,5 10,0 H10295 H979 H2561

8 17,0 6,5 13,0 H10296 H980 H2562

10 11,0 19,0 7,5 14,0 H10297 H981 H2563

6 7/1,05 4

4

3,4 5,3

12,0 4,5 7,5 H10298 H2857 H2564

5 12,0 4,5 8,5 H10299 H982 H2565

6 8,5 13,0 5,5 9,5 H10300 H983 H2566

8 9,3 17,0 7,0 13,0 H10301 H984 H2567

10 11,0 19,0 7,5 15,0 H10302 H985 -

10 7/1,36 6

5 10,5 12,0 4,5 9,0 H10303 H987 H2568

6 10,5 13,0 6,0 10,0 H10304 H988 H2569

8 4,4 6,3 11,0 17,0 7,5 13,0 H10305 H989 H2570

10 11,0 19,0 7,5 15,0 H10306 H990 H2571

12 12,0 20,0 10,0 19,0 H10307 H991 H2572

16 7/1,72 10

5 13,0 5,5 10,5 H10308 H993 H2574

6 13,0 5,5 11,0 H10309 H994 H2575

8 5,5 7,6 12,0 18,0 7,5 13,0 H10310 H995 H2576

10 20,0 7,5 15,0 H10311 H996 H2577

12 25,0 10,5 18,0 H10312 H997 H2578

16 27,0 13,0 24,0 H10313 H998 H2579

25

18/1,35

16

6 16,0 6,0 14,0 H10314 H999 H2581

8 17,0 8,0 14,0 H10315 H1000 H2582

19/1,55

10 6,9 9,0 15,0 18,0 8,0 16,0 H10316 H1001 H2583

12 21,0 11,0 18,0 H10475 H1002 H2584

16 27,0 13,0 24,0 H10317 H338 -

Note: • Indent compression recommended for flexible stranded.• Confirm stock and brand availability with your local branch.

Components are tested to IEC 61238-1.

Items above with (-) in the codes column are available on special request.

CABLE ACCESSORIES

Page 2: CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES. Copper Lugs for Stranded Conductor Cable. Dimension. 1.he nominal area of the circular

3VOLTEX CATALOGUEFor extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. 111VOLTEX CATALOGUE

Note: • Indent compression recommended for flexible stranded.• Confirm stock and brand availability with your local branch.

Components are tested to IEC 61238-1.

LUGS AND FERRULES

Items above with (-) in the codes column are available on special request.

Copper Lugs for Stranded Conductor Cable

Nominal Lug Size

Typical Conductors

Stud Size

Nominal Dimensions Product Code

Circular Stranded

Flexible Stranded

(mm)

Barrel Spade

(mm2) (mm) (mm2) (mm)A B C D E F

I.D O.D Length Length Hole Pos. Width

35

18/1,59

25

6 15,0 18,0 8,0 16,0 H10318 H1003 H2585

8 15,0 18,0 9,0 16,0 H10319 H1004 H2586

19/1,55

10 8,2 10,7 15,0 18,0 9,0 16,0 H10320 H1005 H2587

12 15,0 22,0 10,0 18,0 - H1006 H2588

16 16,0 30,0 13,0 24,0 H10321 H1007 H2589

50 18/1,9 19/1,85

35

6 16,0 17,0 8,0 18,0 H10322 H1008 H2590

8 16,0 17,0 9,0 18,0 H10323 H1009 H2591

10 17,0 24,0 10,0 20,0 H10324 H1010 H2592

12 10,0 12,8 18,0 24,0 10,0 20,0 - H1012 H2593

16 18,0 30,0 13,0 26,0 H10325 H1013 H2594

20 18,0 30,0 13,0 26,0 H10326 H3266 -

70 18/2,2519/2,19 50

8 20,5 20,0 9,5 21,0 H10327 H1014 H2597

10 21,0 26,0 11,0 22,0 H10328 H1015 H2598

12 11,7 15,0 21,0 28,0 12,0 22,0 H10329 H1017 H2599

16 22,0 32,0 14,0 28,0 - H1018 H1342

20 22,0 34,0 15,0 30,0 H10330 H1175 H2600

95 36/1,8637/1,83 70

8 24,0 9,5 25,0 H10331 H1019 H2601

10 26,0 13,0 26,0 H10332 H1020 H2602

12 13,5 17,4 23,0 28,0 13,0 26,0 H10333 H1022 H2603

16 32,0 14,0 28,0 - H1023 H2604

20 36,0 16,0 30,0 H10334 H1176 H2605

120

36/2,08

70/95

10 26,0 12,0 27,0 H10335 H1024 H2606

12 28,0 12,0 28,0 H10336 H1025 H2607

37/2,0516 15,5 19,8 26,0 32,0 14,0 30,0 H10337 H1026 H2608

20 36,0 16,0 32,0 H10338 H2861 -

150

36/2,34

95/120

10 31,0 12,5 31,0 H10339 H1027 H2609

12 33,0 16,0 32,0 H10340 H1028 H2610

37/2,2916 17,0 22,0 27,0 35,0 16,0 32,0 H10341 H1029 H1343

20 36,0 16,0 32,0 H10342 H1030 H2661

185

36/2,59

120/150

10 29,0 12,5 34,0 H10343 H1031 H2611

12 31,0 16,0 34,0 H10344 H1032 H2612

37/2,5316 19,0 24,4 29,0 34,0 16,0 36,0 H10345 H1033 H2613

20 H10346 H1179 -

240

60/2,23

150/185

10 36,0 16,0 40,0 H10347 H1180 H2614

12 36,0 16,0 40,0 H10348 H1034 H2615

61/2,2616 21,5 27,7 33,0 38,0 20,0 40,0 H10349 H1884 H2616

20 42,0 20,0 40,0 H10350 H3267 H2617

300 60/2,5561/2,53 185/240

10 35,0 15,0 45,0 H10351 H3268 -

12 24,5 31,3 35,0 35,0 15,0 45,0 H10352 H1289 H2618

16 45,0 15,0 45,0 H10353 H367 -

20 45,0 16,0 45,0 H10354 H2863 H2619

400 91/2,39 240/300 16 27,5 35,6 41,047,0 49,0 - H4281 -

47,0 24,0 51,0 - H4280 H368

500 91/2,67 300/400 31,6 40,0 41,5 54,0 58,0 H369 H4282 -

630 127/2,54 400/500 34,5 44,6 53,0 65,0 64,0 H370 H4283 -

800 127/2,87 630 40,0 51,2 68,0 75,0 73,0 - H4284 -

1000 127/3,22 44,0 56,6 75,0 75,0 81,0 - H4285 -

CABLE ACCESSORIES

Page 3: CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES. Copper Lugs for Stranded Conductor Cable. Dimension. 1.he nominal area of the circular

2 VOLTEX CATALOGUEFor extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.112 VOLTEX CATALOGUE

LUGS AND FERRULESHeavy Duty Copper Lugs for Compacted XLPE Cable 6.35 - 11kV

Nominal Lug Size

SANS1411-1

Nominal Diameter

Over Cond.

Stud Size

Nominal Dimensions

Product Code

(mm)

Barrel Spade

(mm2) (mm)A B C D E F

I.D O.D Length Length Hole Pos. Width

35 7,0 10 7,30 10,50 16,0 24,0 11,0 19,0 H4130

50 8,2 10 8,75 12,30 20,0 24,0 11,0 19,0 H4131

70 9,7 10 10,40 14,60 21,0 27,0 14,0 20,0 H4132

95 11,4 10 12,10 17,00 24,0 28,0 14,0 24,0 H4133

120 12,6 12 14,00 19,10 26,0 28,0 14,0 26,0 H4134

150 14,6 12 15,25 21,30 31,0 37,0 18,0 30,0 H4135

185 15,9 12 17,00 23,70 34,0 40,0 19,0 33,0 H4136

240 16,3 12 20,00 27,10 34,0 41,0 19,0 37,0 H4137

300 20,8 * 21,63 30,50 38,0 48,0 20,0 42,5 H4138

400 23,6 * 24,50 34,64 51,0 49,0 23,5 48,0 H4139

500 26,2 * 28,50 38,90 51,0 52,0 25,0 54,0 H4140

630 30,3 * 33,00 45,00 53,0 65,0 28,0 64,0 H4141

B A

C D

F

ER1

Note: * Stud sizes can be made to customer requirements.

Components are tested to IEC 61238-1.

CABLE ACCESSORIES

Page 4: CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES. Copper Lugs for Stranded Conductor Cable. Dimension. 1.he nominal area of the circular

3VOLTEX CATALOGUEFor extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. 113VOLTEX CATALOGUE

LUGS AND FERRULESAluminium Stranded Circular Cable Lugs

Cable Stud SIzeA B C D E

Palm width Palm Thick

d1 d2 Product Code

(mm2) (mm) "F" "G"

25

8

65,00 28,00

8,40

17,00 12,0015,00 4,00

7,00 11,30

H4158

10 10,40 H4159

12 12,50 21,00 3,00 H4160

35

8

70,00 30,00

8,40

17,00 12,0017,50 4,00

8,30 12,90

H4161

10 10,40 H4162

12 12,50 21,00 3,50 H4163

50

10

70,0 32,00

10,40

17,00 12,0020,00 4,50

9,90 14,70

H4164

12 12,50 H4165

16 16,50 26,00 3,50 H4166

70

10

78,00 36,00

10,40

17,00 12,0023,00 5,00

11,70 17,00

H4167

12 12,50 H4168

16 16,50 26,00 4,50 H4169

95

10

85,00 39,00

10,40

18,00 12,00 27,50 5,50 13,70 19,70

H4170

12 12,50 H4171

16 16,50 H4172

120

10

89,00 45,00

10,40

17,00 12,00 31,00 6,50 15,30 22,20

H4173

12 12,50 H4174

16 16,50 H4175

150

12

100,00 48,00

12,50

20,00 16,00 34,50 7,00 17,20 24,70

H4176

16 16,50 H4177

20 20,50 H4178

185

12

108,00 53,00

12,50

20,00 16,00 38,00 7,50 19,00 27,30

H4179

16 16,50 H4180

20 20,50 H4181

240On request

118,00 57,00On request

22,00 18,00 43,50 8,50 21,80 31,00 H4182

300 132,00 62,00 25,00 20,00 49,00 9,50 24,90 35,00 H4183

Note:Components are tested to IEC 61238-1.

CABLE ACCESSORIES

Page 5: CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES. Copper Lugs for Stranded Conductor Cable. Dimension. 1.he nominal area of the circular

2 VOLTEX CATALOGUEFor extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.114 VOLTEX CATALOGUE

Note:Components are tested to IEC 61238-1.

LUGS AND FERRULESAluminium 3 Core Sector Shaped Cable Lugs

Cable Stud SIzeA B C D E

Palm width Palm Thick

d1 d2 Product Code

(mm2) (mm) "F" "G"

25

8

65,00 28,00

8,40

17,00 12,0015,00 4,00

5,20 8,73

H4184

10 10,40 H4185

12 12,50 21,00 3,00 H4186

35

8

70,00 30,00

8,40

17,00 12,0017,50 4,5

5,90 10,05

H4187

10 10,40 H4188

12 12,50 21,00 3,50 H4189

50

10

70,00 32,00

10,40

17,00 12,0022,00 4,50

7,25 11,85

H4190

12 12,50 H4191

16 16,50 26,00 3,50 H4192

70

10

78,00 36,00

10,40

17,00 12,0024,00 5,00

8,5 14,10

H4193

12 12,50 H4194

16 16,50 26,00 4,50 H4195

95

10

82,00 38,00

10,40

18,00 12,00 28,00 6,00 9,55 16,35

H4196

12 12,50 H4197

16 16,50 H4198

120

10

88,00 45,00

10,40

17,00 12,00 31,00 6,50 11,05 18,50

H4199

12 12,50 H4200

16 16,50 H4201

150

12

103,00 48,00

12,50

20,00 18,00 34,00 7,00 12,15 20,60

H4202

16 16,50 H4203

20 20,50 H4204

185

12

106,00 53,00

12,50

20,00 18,00 38,00 8,50 13,40 22,48

H4205

16 16,50 H4206

20 20,50 H4207

240On request

118,00 57,00On request

22,00 18,00 43,50 8,50 15,55 26,05 H4208

300 132,00 62,00 25,00 20,00 49,00 10,00 17,35 29,00 H4209

CABLE ACCESSORIES

Page 6: CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES. Copper Lugs for Stranded Conductor Cable. Dimension. 1.he nominal area of the circular

3VOLTEX CATALOGUEFor extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. 115VOLTEX CATALOGUE

LUGS AND FERRULESAluminium 4 Core Sector Shaped Cable Lugs

Cable Stud SIzeA B C D E

Palm width Palm Thick

d1 d2 Product Code

(mm2) (mm) "F" "G"

25

8

65,00 25,00

8,40

17,00 12,0015,00 4,00

5,80 7,88

H4210

10 10,40 H4211

12 12,50 21,00 3,00 H4212

35

8

70,00 30,00

8,40

17,00 12,0017,50 4,5

7,10 9,70

H4213

10 10,40 H4214

12 12,50 21,00 3,50 H4215

50

10

70,00 32,00

10,40

17,00 12,0020,00 4,50

8,35 10,95

H4216

12 12,50 H4217

16 16,50 26,00 3,00 H4218

70

10

78,00 36,00

10,40

17,00 12,0023,00 5,00

9,30 13,00

H4219

12 12,50 H4220

16 16,50 26,00 4,50 H4221

95

10

85,00 39,00

10,40

18,00 12,00 27,50 5,70 10,85 15,10

H353

12 12,50 H1021

16 16,50 H4222

120

10

89,00 45,00

10,40

17,00 12,00 31,00 6,50 12,05 17,00

H4223

12 12,50 H4224

16 16,50 H4225

150

12

100,00 48,00

12,50

20,00 16,00 34,50 7,20 13,80 18,80

H4226

16 16,50 H4227

20 20,50 H4228

185

12

108,00 53,00

12,50

20,00 16,00 38,50 8,00 15,25 21,00

H363

16 16,50 H4229

20 20,50 H4230

240On request

118,00 57,00On request

22,00 18,00 43,50 8,50 17,35 23,80 H4231

300 132,00 62,00 25,00 20,00 49,00 9,70 19,50 26,40 H4232

Note:Components are tested to IEC 61238-1.

CABLE ACCESSORIES

Page 7: CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES. Copper Lugs for Stranded Conductor Cable. Dimension. 1.he nominal area of the circular

2 VOLTEX CATALOGUEFor extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.116 VOLTEX CATALOGUE

LUGS AND FERRULES

Heavy Duty Copper Ferrules for Compacted XLPE Cable 6.35 - 11kV

Copper Ferrules for Stranded Conductor Cable

Nominal Sleeve Size

Nominal DimensionsTypical

Conductors Circular Stranded

Product Code

(mm)

I.D O.D Length

(mm2) A B C (mm)

1,5 1,9 3,6 13,0 3/0,81 H10367 H121 H2514

2,5 2,4 3,9 14,0 3/1,04 H10368 H124 H2515

4 2,8 4,7 16,0 7/0,86 H10369 H126 H2516

6 3,4 5,3 18,0 7/1,05 H10370 H129 H2517

10 4,4 6,3 20,0 7/1,36 H10371 H131 H2518

16 5,5 7,6 22,0 7/1,72 H10372 H133 H2519

25 6,9 9,0 25,0 18/1,35 H2174 H137 H2520

35 8,2 10,7 28,0 18/1,59 H2175 H141 H2521

50 10,0 12,8 31,0 18/1,90 H2176 H144 H2522

70 11,7 15,0 35,0 18/2,25 H23 H147 H2523

95 13,5 17,4 39,0 36/1,86 H2928 H151 H2524

120 15,5 19,8 43,0 36/2,08 H2177 H155 H2525

150 17,0 22,0 48,0 36/2,34 H2178 H159 H2526

185 19,0 24,4 54,0 36/2,59 H10373 H162 H2527

240 21,5 27,7 60,0 60/2,23 H10374 H165 H2528

300 24,5 31,3 67,0 60/2,55 H10375 H167 H2529

400 27,5 35,6 80,0 91/2,39 H10376 H3265 H2530

500 31,6 40,0 90,0 91/2,67 H10377 H4154 -

630 34,5 44,6 110,0 127/2,54 H10378 H4155 -

800 40,0 51,2 130,0 127/2,87 H10379 H4156 -

1000 44,0 56,6 154,0 127/3,22 H10380 H4157 -

Nominal Ferrule Size

Nominal Dimensions

Product Code(mm)

I.D O.D Length

(mm2) A B C

35 7,30 10,5 38 H4142

50 8,75 12,3 42 H4143

70 10,40 14,6 43 H4144

95 12,10 17,0 45 H4145

120 14,00 19,1 55 H4146

150 15,25 21,3 58 H4147

185 17,00 23,7 64 H4148

240 20,00 27,1 70 H4149

300 21,63 30,5 75 H4150

400 24,50 34,6 80 H4151

500 28,50 38,9 90 H4152

630 33,00 45,0 100 H4153

C

AB

Note:Components are tested to IEC 61238-1.

For items marked with a dash (-) please enquire at branch or reference website

CABLE ACCESSORIES

Page 8: CABLE ACCESSORIES LUGS AND FERRULES · Complete T Cs at back of catalogue. LUGS AND FERRULES. Copper Lugs for Stranded Conductor Cable. Dimension. 1.he nominal area of the circular

3VOLTEX CATALOGUEFor extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. 117VOLTEX CATALOGUE

LUGS AND FERRULESAluminium Ferrules

Cable AStranded 3 Core 4 Core

D1 D2 Product Code H W Product

Code H W Product Code(mm2) (mm)

25 66 7,00 11,30 H135 5,20 8,73 H4286 5,8 7,88 H4296

35 70 8,30 12,90 H139 10,05 5,90 H4287 7,10 9,70 H4297

50 74 9,90 14,70 H142 11,85 7,25 H4288 8,35 10,95 H4298

70 78 11,70 17,00 H145 14,10 8,25 H4289 9,30 13,00 H4299

95 84 13,70 19,70 H149 16,35 9,55 H4290 10,85 15,10 H4300

120 91 15,30 22,20 H153 18,50 11,05 H4291 12,50 17,00 H4301

150 102 17,20 24,70 H157 20,60 12,15 H4292 13,80 18,80 H4302

185 108 19,00 27,30 H160 22,40 13,40 H4293 15,25 21,00 H4303

240 118 21,80 31,00 H163 26,05 15,55 H4294 17,35 23,80 H4304

300 130 24,90 35,00 H4233 29,00 17,35 H4295 19,50 26,40 H4305

Note:Components are tested to IEC 61238-1.

Stranded 3 Core 4 Core

A

CABLE ACCESSORIES