CA44 Catalog

14
Double Impact: Rexroth CA44. Extremely Adaptable, Easy Assembly Pneumatic valve manifold system with integrated AS-i

Transcript of CA44 Catalog

Page 1: CA44 Catalog

Double Impact: Rexroth CA44. Extremely Adaptable, Easy Assembly

Pneumatic valve manifold system with integrated AS-i

Page 2: CA44 Catalog

Two Become One:

CA44 Valve Terminal System Integrates All

the Valve Functions of Two Standard Air Boxes

CA44 is a new innovation from Rexroth that combines the benefi ts of a standard air

box with the fl exibility of a classic valve terminal system. This new product is the most

compact four-valve solution with AS-i connection on today’s market.

Extremely adaptable and effi cient–

CA44 is the intelligent solution for

integrating pneumatic valves in

systems with AS-i bus structures:

■ Compact installation sizes■ Valve functions can be combined as desired■ Easy to install: all connections are located on one side■ Valve exchange without changing the address■ Just one AS-i address for four valve functions and four electric inputs■ Long service life, more than

100 million cycles

CA44 is smaller than two air boxes and signifi cantly smaller than all other valve terminal systems with similar functions.

For valve functions that up until

now needed two air boxes–one

Rexroth CA44 can do it all.

AS-i coupling module

An AS-i coupling module is used to connect CA44: simply plug the module onto the AS-i cable.

■ Standard component■ Direct mounting onto DIN rail■ Resistant against polarity reversal

CA44 is delivered

fully assembled and

tested

www.boschrexroth-us.com/brp

All MC series valves available,

even double solenoid 4/2-way

valves

Four electric

inputs with M8

connection

Two valve slots with a

maximum of four valve

functions

Pneumatic air supply

and exhaust air

Valve terminal with

integrated AS-i electronics

(AS-i chip with address)

Page 3: CA44 Catalog

1

Valve Terminal System, Series CA44 AS-i/DI/AUX, metric and inch versions

Technical Data

GeneralDegree of protection according toEN 60 529/IEC 529 IP 67 (NEMA 6)when assembledAmbient temperature range 0 °C to +50 °C (+32 °F to +122 °F)Nominal flow Qn 200 l/min (0.2 Cv)

AS-i busI/O code 7ID code / ID2 code F / ERated voltage according to AS-i specifcations 26,5 - 31,6 VPower consumption max. 205 mA

Sensor supply AS-i busCurrent per triggered input 5 mA (short-circuit proof)Total output for sensors max. 150 mA (short-circuit proof)

Load supply 24 V DC externalRated voltage 24 V DC (-15% / +20%)Protective min. voltage (PELV) according to IEC 60364-4-41Residual ripple 0,5 %Rated current per valve solenoid 20 mA

Electromagnetic compatibility EN 50295

Application areaThis AS-i bus module comply with the AS-i specification V2.11 Rev. 1;Jan. 31, 2001. AB Address/Module)

Allocation scheme and manual

AS-i Data bit Manualvalve position D0 D3 D1 D2

1 solenoid 14 solenoid 12 -- --2 -- -- solenoid 14 solenoid 12 R499050024

AS-Interface module with MC-valve, with silencer, without coupling module - METRIC version

MC- Valves turn, detentoverride

MC- Valves turnoverride

Metric version ( Port 1 = 8 mm, Port 3 = 10 mm)

Valve position 1 Valve position 2 Code Part no. Valve position 1 Valve position 2 Code Part no.2x3/2 WV, NC, D=4

0820057105Blanking plate1825700086

DI/AUX 5R/ X R480034011

2x3/2 WV, NC, D=60820057101

Blanking plate1825700086

DI/AUX GR/ X R480034012

2x 2x3/2 WV, NC, D=40820057105

DI/AUX 5R/5R R480034016 2x 2x3/2 WV, NC, D=40820057106

DI/AUX 5N/5N R480034039

2x 2x3/2 WV, NC, D=60820057101

DI/AUX GR/GR R480034017 2x 2x3/2 WV, NC, D=60820057102

DI/AUX GN/GN R480034030

2x 2x3/2 WV, NO, D=40820057205

DI/AUX 6R/6R R480034018 2x 2x3/2 WV, NO, D=40820057206

DI/AUX 6N/6N R480034033

2x 2x3/2 WV, NO, D=60820057201

DI/AUX HR/HR R480034019 2x 2x3/2 WV, NO, D=60820057202

DI/AUX HN/HN R480034034

2x 2x3/2 WV, NC/NO, D=40820057305

DI/AUX 7R/7R R480034022 2x 2x3/2 WV, NC/NO, D=40820057306

DI/AUX 7N/7N R480034035

2x 2x3/2 WV, NC/NO, D=60820057301

DI/AUX IR/IR R480034020 2x 2x3/2 WV, NC/NO, D=60820057302

DI/AUX IN/IN R480034038

2x 4/2 WV, single pilot, D=40820057005

DI/AUX 1R/1R R480034023 2x 4/2 WV, single pilot, D=40820057006

DI/AUX 1N/1N R480034040

2x 4/2 WV, single pilot, D=60820057001

DI/AUX AR/AR R480034025 2x 4/2 WV, single pilot, D=60820057002

DI/AUX AN/AN R480034041

2x 4/2 WV, double pilot, D=4412003515

DI/AUX BN/BN R480034043

2x 4/2 WV, double pilot, D=6412003517

DI/AUX BN/BN R480034044

D = tube outside diameter

Working pressure range 2.0 - 8 bar (29 - 116 psi)

Page 4: CA44 Catalog

Valve Terminal System, Series CA44 AS-i/DI/AUX, metric and inch versions

2

AS-Interface module without MC-valve, without silencer and without coupling module (metric)

Metric version (port 1 = 8 mm, port 3 = 10 mm) Code Part no.

CA44/AS-i/DI/AUX (DI = digital input, AUX = auxiliary power) basic module DI/AUX R480034442

Other combinations on our Internet Configurator, or contact the nearest Bosch Rexroth sales office.

AS-Interface module without MC-valve, without silencer and without coupling module (inch)

Inch version (port 1 = 1/4 ", port 3 = 3/8 ") Code Part no.

CA44/AS-i/DI/AUX (DI = digital input, AUX = auxiliary power) basic module DI/AUX R412006942

Other combinations on our Internet Configurator, or contact the nearest Bosch Rexroth sales office.

AS-Interface module with MC-valve, with silencer, without coupling module - INCH version

Accessories (to be ordered separately)

Accessories for metric and inch version Cable-length[m] (ft.)

Part no.

Coupling module with AUX -- R412000302Connection cable, straight, with threaded coupling, M8x1, 3-pin 3 (9.8) 8946203602Connection cable, straight, with threaded coupling, M8x1, 3-pin 5 (16.4) 8946203612Connection cable, straight, with threaded coupling, M8x1, 3-pin 10 (32.8) 8946203622

Protection cap M8x1 (delivery unit: 25 pcs) -- R412003493Valve labels (4 frames with 40 labels each) -- 1829929023

Silencer Ø10 mm -- R412000593

Valve position 1 & 2Valve material number Code Part no.

Valve position 1 & 2Valve material number Code Part no.

2x 2x3/2 WV, NC, D=M70820057107 DI/AUX GR/GR R480250734

2x 2x3/2 WV, NC, D=M70820057108 DI/AUX GN/GN R480250737

2x 2x3/2 WV, NC, D=40820057105 DI/AUX GR/GR R480250735

2x 2x3/2 WV, NC, D=40820057106 DI/AUX GN/GN R480250738

2x 2x3/2 WV, NC, D=60820057101 DI/AUX GR/GR R480250736

2x 2x3/2 WV, NC, D=60820057102 DI/AUX GN/GN R480250739

2x 2x3/2 WV, NO, D=M70820057207 DI/AUX HR/HR R480250740

2x 2x3/2 WV, NO, D=M70820057208 DI/AUX HN/HN R480250743

2x 2x3/2 WV, NO, D=40820057205 DI/AUX HR/HR R480250741

2x 2x3/2 WV, NO, D=40820057206 DI/AUX HN/HN R480250744

2x 2x3/2 WV, NO, D=60820057201 DI/AUX HR/HR R480250742

2x 2x3/2 WV, NO, D=60820057202 DI/AUX HN/HN R480250745

2x 2x3/2 WV, NC/NO, D=M70820057307 DI/AUX IR/IR R480250746

2x 2x3/2 WV, NC/NO, D=M70820057308 DI/AUX IN/IN R480250749

2x 2x3/2 WV, NC/NO, D=40820057305 DI/AUX IR/IR R480250747

2x 2x3/2 WV, NC/NO, D=40820057306 DI/AUX IN/IN R480250751

2x 2x3/2 WV, NC/NO, D=60820057301 DI/AUX IR/IR R480250748

2x 2x3/2 WV, NC/NO, D=60820057302 DI/AUX IN/IN R480250752

2x 4/2 WV, single solenoid, D=M70820057007 DI/AUX AR/AR R480250753

2x 4/2 WV, single solenoid, D=M70820057008 DI/AUX AN/AN R480250756

2x 4/2 WV, single solenoid, D=40820057005 DI/AUX AR/AR R480250754

2x 4/2 WV, single solenoid, D=40820057006 DI/AUX AN/AN R480250757

2x 4/2 WV, single solenoid, D=60820057001 DI/AUX AR/AR R480250755

2x 4/2 WV, single solenoid, D=60820057002 DI/AUX AN/AN R480250758

2x 4/2 WV, double solenoid, D=M7R412003518 DI/AUX BN/BN R480250759

2x 4/2 WV, double solenoid, D=4R412003515 DI/AUX BN/BN R480250760

2x 4/2 WV, double solenoid, D=6R412003517 DI/AUX BN/BN R480250761

*Manifold ports are inch, the individual MC valves are metric ported as shown in table.

MC- Valves turn, detent override MC- Valves turn override

Inch version (port 1 = 1/4", port 3 = 3/8")*

Page 5: CA44 Catalog

Valve Terminal System, Series CA44 AS-i/DI/AUX, metric and inch versions

3

1 = Valve position 12 = Valve position 23 = Coupling module4 = 4 x Mounting screw

Metric manifold: Port 1 = 8mm, Port 3 = 10mmInch manifold: Port 1 = 1/4", Port 3 = 3/8"

Input M8

Page 6: CA44 Catalog

Valve Terminal System, Series CA44 AS-i/DI, metric and inch versions

4

Technical Data

GeneralDegree of protection according toEN 60 529/IEC 529 IP 67 (NEMA 6)when assembledAmbient temperature range 0 °C to +50 °C (+32 °F to +122 °F)Nominal flow Qn 200 l/min (0.2 Cv)

AS-i busI/O code 7ID code / ID2 code F / ERated voltage according to AS-i specifcations 26,5 - 31,6 VPower consumption max. 265 mACurrent per valve solenoid 20 mA

Sensor supply AS-i busTotal output for sensors max. 150 mA (short-circuit proof)Current per triggered input 5 mA (short-circuit proof)

Electromagnetic compatibility EN 50295

Application areaThis AS-i bus module comply with the AS-i specification V2.11 Rev. 1; Jan. 31, 2001.(AB Address/Module)

Allocation scheme and manual

AS-i Data bit Manualvalve position D0 D3 D1 D2

1 solenoid 14 solenoid 12 -- --2 -- -- solenoid 14 solenoid 12 R499050025

AS-Interface module with MC-valve and with silencer, without coupling module

MC- Valves turn, detentoverride

MC- Valves turnoverride

Metric version (port 1 = 8 mm, port 3 = 10 mm)

Valve position 1 Valve position 2 Code Part no. Valve position 1 Valve position 2 Code Part no.2x 2x3/2 WV, NC, D=4

0820057105DI 5R/5R R480034045 2x 2x3/2 WV, NC, D=4

0820057106DI 5N/5N R480034056

2x 2x3/2 WV, NC, D=60820057101

DI GR/GR R480034046 2x 2x3/2 WV, NC, D=60820057102

DI GN/GN R480034057

2x 2x3/2 WV, NO, D=40820057205

DI 6R/6R R480034047 2x 2x3/2 WV, NO, D=40820057206

DI 6N/6N R480034058

2x 2x3/2 WV, NO, D=60820057201

DI HR/HR R480034048 2x 2x3/2 WV, NO, D=60820057202

DI HN/HN R480034059

2x 2x3/2 WV, NC/NO, D=40820057305

DI 7R/7R R480034049 2x 2x3/2 WV, NC/NO, D=40820057306

DI 7N/7N R480034060

2x 2x3/2 WV, NC/NO, D=60820057301

DI IR/IR R480034050 2x 2x3/2 WV, NC/NO, D=60820057302

DI IN/IN R480034061

2x 4/2 WV, single pilot, D=40820057005

DI 1R/1R R480034052 2x 4/2 WV, single pilot, D=40820057006

DI 1N/1N R480034062

2x 4/2 WV, single pilot, D=60820057001

DI AR/AR R480034053 2x 4/2 WV, single pilot, D=60820057002

DI AN/AN R480034063

2x 4/2 WV, double pilot, D=4412003515

DI BN/BN R480034054

2x 4/2 WV, double pilot, D=6412003517

DI BN/BN R480034055

D = tube outside diameter

AS-Interface module without MC-valve, without silencer and without coupling module (metric)

Metric version ( port 1 = 8 mm, port 3 = 10 mm) Code Part no.

CA44/AS-i/DI (DI = digital input) basic module AS-i/DI R480034443

Other combinations on our Internet Configurator, or contact the nearest Bosch Rexroth sales office.

Working pressure range 2.0 - 8 bar (29 - 116 psi)

Page 7: CA44 Catalog

5

Valve Terminal System, Series CA44 AS-i/DI, metric and inch versions

AS-Interface module without MC-valve, without silencer and without coupling module (inch)

Inch version (port 1 = 1/4 ", port 3 = 3/8 ") Code Part no.

CA44/AS-i/DI (DI = digital input) basic module AS-i/DI R412006944

Other combinations on our Internet Configurator, or contact the nearest Bosch Rexroth sales office.

Accessories (to be ordered separately)

Accessories for metric and inch version Cable-length[m] (ft.)

Part no.

Coupling module -- R412000299Connection cable, straight, with threaded coupling, M8x1, 3-pin 3 (9.8) 8946203602Connection cable, straight, with threaded coupling, M8x1, 3-pin 5 (16.4) 8946203612Connection cable, straight, with threaded coupling, M8x1, 3-pin 10 (32.8) 8946203622

Protection cap M8x1 (delivery unit: 25 pcs) -- R412003493Valve labels (4 frames with 40 labels each) -- 1829929023

Silencer Ø10 mm -- R412000593

Valve position 1 & 2Valve material number Code Part no.

Valve position 1 & 2Valve material number Code Part no.

2x 2x3/2 WV, NC, D=M70820057107 DI GR/GR R480250702

2x 2x3/2 WV, NC, D=M70820057108 DI GN/GN R480250705

2x 2x3/2 WV, NC, D=40820057105 DI GR/GR R480250703

2x 2x3/2 WV, NC, D=40820057106 DI GN/GN R480250706

2x 2x3/2 WV, NC, D=60820057101 DI GR/GR R480250704

2x 2x3/2 WV, NC, D=60820057102 DI GN/GN R480250707

2x 2x3/2 WV, NO, D=M70820057207 DI HR/HR R480250708

2x 2x3/2 WV, NO, D=M70820057208 DI HN/HN R480250711

2x 2x3/2 WV, NO, D=40820057205 DI HR/HR R480250709

2x 2x3/2 WV, NO, D=40820057206 DI HN/HN R480250712

2x 2x3/2 WV, NO, D=60820057201 DI HR/HR R480250710

2x 2x3/2 WV, NO, D=60820057202 DI HN/HN R480250713

2x 2x3/2 WV, NC/NO, D=M70820057307 DI IR/IR R480250714

2x 2x3/2 WV, NC/NO, D=M70820057308 DI IN/IN R480250717

2x 2x3/2 WV, NC/NO, D=40820057305 DI IR/IR R480250715

2x 2x3/2 WV, NC/NO, D=40820057306 DI IN/IN R480250718

2x 2x3/2 WV, NC/NO, D=60820057301 DI IR/IR R480250716

2x 2x3/2 WV, NC/NO, D=60820057302 DI IN/IN R480250719

2x 4/2 WV, single solenoid, D=M70820057007 DI AR/AR R480250720

2x 4/2 WV, single solenoid, D=M70820057008 DI AN/AN R480250723

2x 4/2 WV, single solenoid, D=40820057005 DI AR/AR R480250721

2x 4/2 WV, single solenoid, D=40820057006 DI AN/AN R480250724

2x 4/2 WV, single solenoid, D=60820057001 DI AR/AR R480250722

2x 4/2 WV, single solenoid, D=60820057002 DI AN/AN R480250725

2x 4/2 WV, double solenoid, D=M7R412003518 DI BN/BN R480250726

2x 4/2 WV, double solenoid, D=4R412003515 DI BN/BN R480250727

2x 4/2 WV, double solenoid, D=6R412003517 DI BN/BN R480250728

*Manifold ports are inch, the individual MC valves are metric ported as shown in table.

MC- Valves turn, detent override MC- Valves turn override

Inch version (port 1 = 1/4", port 3 = 3/8")*

Page 8: CA44 Catalog

Valve Terminal System, Series CA44 AS-i/DI, metric and inch versions

6

Metric manifold: Port 1 = 8mm, Port 3 = 10mmInch manifold: Port 1 = 1/4", Port 3 = 3/8"

Input M8

1 = Valve position 12 = Valve position 23 = Coupling module4 = 4 x Mounting screw

Page 9: CA44 Catalog

7

Valve Terminal System, Series CA44 AS-i/AUX, metric only

Technical Data

GeneralDegree of protection according toEN 60 529/IEC 529 IP 67 (NEMA 6) when assembledAmbient temperature range 0 °C to +50 °C (+32 °F to +122 °F)Nominal flow Qn 200 l/min (0.2 Cv)

AS-i busI/O code 8ID code / ID2 code F / ERated voltage according to AS-i specifcations 26,5 - 31,6 VPower consumption max. 35 mA

Load supply 24 V DC externalRated voltage 24 V DC (-15% / +20%)Protective min. voltage (PELV) according to IEC 60364-4-41Residual ripple 0,5 %Rated current per valve solenoid 20 mA

Electromagnetic compatibility EN 50295

Application areaThis AS-i bus module comply with the AS-i specification V2.11 Rev. 1; Jan. 31, 2001.(AB Address/Module)

Allocation scheme and manual

AS-i Data bit Manualvalve position D0 D3 D1 D2

1 solenoid 14 solenoid 12 -- --2 -- -- solenoid 14 solenoid 12 R499050071

AS-Interface module without MC-valve, without silencer and without coupling module (port 1 = 8mm, port 3 = 10 mm)

Module Code Part no.

CA44/AS-i/AUX(AUX = auxiliary power)

basic moduleAS-i/AUX R480034444

Other combinations on our Internet Configurator, or contact the nearest Bosch Rexroth sales office.

Accessories (to be ordered separately)

Accessories Part no.Coupling module with AUX R412000302

Silencer Ø10 R412000593Valve labels (4 frames with 40 labels each) 1829929023

Working pressure range 2.0 - 8 bar (29 - 116 psi)

Page 10: CA44 Catalog

Valve Terminal System, Series CA44 AS-i/AUX 1, metric only

8

1 = Valve position 12 = Valve position 23 = Coupling module4 = 4 x Mounting screw

Page 11: CA44 Catalog

9

Valve Terminal System, Series CA44 AS-i, metric only

Technical Data

GeneralDegree of protection according toEN 60 529/IEC 529 IP 67 (NEMA 6) when assembledAmbient temperature range 0 °C to +50 °C (+32 °F to +122 °F)Nominal flow Qn 200 l/min (0.2 Cv)

AS-i busI/O code 8ID code / ID2 code F / ERated voltage according to AS-i specifcations 26,5 - 31,6 VPower consumption max. 95 mACurrent per valve solenoid 20 mA

Electromagnetic compatibility EN 50295

Application areaThis AS-i bus module comply with the AS-i specification V2.11 Rev. 1; Jan. 31, 2001.(AB Address/Module)

Allocation scheme and manual

AS-i Data bit Manualvalve position D0 D3 D1 D2

1 solenoid 14 solenoid 12 -- --2 -- -- solenoid 14 solenoid 12 R499050072

AS-Interface module without MC-valve, without silencer and without coupling module ( port 1 = 8 mm, port = 10 mm)

Module Code Part no.

CA44/AS-ibasic module AS-i R480034445

Other combinations on our Internet Configurator, or contact the nearest Bosch Rexroth sales office.

Accessories (to be ordered separately)

Accessories Part no.Coupling module R412000299

Silencer Ø10 R412000593Valve labels (4 frames with 40 labels each) 1829929023

Working pressure range 2.0 - 8 bar (29 - 116 psi)

Page 12: CA44 Catalog

Valve Terminal System, Series CA44 AS-i, metric only

10

1 = Valve position 12 = Valve position 23 = Coupling module4 = 4 x Mounting screw

Page 13: CA44 Catalog

NOTICES TO PRODUCT USERS1. WARNING: FLUID MEDIA Bosch Rexroth pneumatic devices are designed and tested for use with filtered, clean, dry, chemical free air at pressures and temperatures within the specified limits of the device. For use with media other than air or for human life support systems, Bosch Rexroth must be consulted. Hydraulic cylinders are designed for operation with filtered, clean, petroleum based hydraulic fluid; operation using fire-resistant or other special types of fluids may require special packing and seals. Consult the factory.

2. WARNING: MATERIAL COMPATIBILITY Damage to product seals or other parts caused by the use of non-compatible lubricants, oil additives or synthetic lubricants in the air system compressor or line lubrication devices voids Bosch Rexroth's warranty and can result in product failure or other malfunction. See lubrication recommendations below. AIR LINE LUBRICANTS! In service higher than 18 cycles per minute or with continuous flow of air through the device, an air line lubricator is recommended. * (Do not use line lubrication with vacuum products.) However, the lubricator must be maintained since the oil will wash out the grease, and lack of lubrication will greatly shorten the life expectancy. The oils used in the lubricator must be compatible with the elastomers in the device. The elastomers are normally BUNA-N, NEOPRENE, VITON, SILICONE and HYTREL. Bosch Rexroth recommends the use of only petroleum-based oils without synthetic additives, and with an aniline point between 180° and 210° F. COMPRESSOR LUBRICANTS! All compressors (with the exception of special "oil free" units) pass oil mist or vapor from the internal crankcase lubricating system through to the compressed air. Since even small amounts of non-compatible lubricants can cause severe seal deterioration (which could result in component and system failure) special care should be taken in selecting compatible compressor lubricants. It is recommended that users review the National Fluid Power Association "Recommended Guide Lines For Use Of Synthetic Lubricants In Pneumatic Fluid Power Systems" (NFPA T1-1978).

3. WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable electrical, mechanical, piping and other codes in the installation, operation or repair of these devices.

INSTALLATION! Do not attempt to install, operate or repair these devices without proper training in the technique of working on pneumatic or hydraulic systems and devices, unless under trained supervision. Compressed air and hydraulic systems contain high levels of stored energy. Do not attempt to connect, disconnect or repair these products when system is under pressure. Always exhaust or drain the pressure from system before performing any service work. Failure to do so can result in serious personal injury. MOUNTING! Devices should be mounted and positioned in such manner that they cannot be accidentally operated.

4. WARNING: APPLICATION AND USE OF PRODUCTS The possibility does exist for any device or accessory to fail to operate properly through misuse, wear or malfunction. The user must consider these possibilities and should provide appropriate safe guards in the application or system design to prevent personal injury or property damage in the event of malfunction.

5. WARNING: CONVERSION, MAINTENANCE AND REPAIR When a device is disassembled for conversion to a different configuration, maintenance or repair, the device must be tested for leakage and proper operation after being reassembled and prior to installation.MAINTENANCE AND REPAIR! Maintenance periods should be scheduled in accordance with frequency of use and working conditions. All Bosch Rexroth products should provide minimum of 1,000,000 cycles of maintenance free service when used and lubricated as recommended. However, these products should be visually inspected for defects and given an "in system" operating performance and leakage test once a year. Where devices require major repair as result of the one million cycles, one year, or routine inspection, the device must be disassembled, cleaned, inspected, parts replaced as required, rebuilt and tested for leakage and proper operation prior to installation. See individual catalogs for specific cycle life estimates.

6. PRODUCT CHANGES Product changes including specifications, features, designs and availability are subject to change at any time without notice. For critical dimensions or specifications, contact factory.

*Many Bosch Rexroth pneumatic components can operate with or without air line lubrication; see individual sales catalogs for details.

--Refer to the appropriate service catalog for parts and service information.

LIMITATIONS OF WARRANTIES & REMEDIESBosch Rexroth warrants its products sold by it to be free from defects in material and workmanship to the following: For twelve months after shipment Bosch Rexroth will repair or replace (F.O.B. our works), at its option, any equipment which under normal conditions of use and service proves to be defective in material or workmanship at no charge to the purchaser. No charge will be made for labor with respect to defects covered by this Warranty, provided that the work is done by Bosch Rexroth or any of its authorized service facilities.However, this Warranty does not cover expenses incurred in the removal and reinstallation of any product, nor any downtime incurred, whether or not proved defective. All repairs and replacement parts provided under this Warranty policy will assume the identity, for warranty purposes, of the part replaced, and the warranty on such replacement parts will expire when the warranty on the original part would have expired. Claims must be submitted within thirty days of the failure or be subject to rejection. This Warranty is not transferable beyond the first using purchaser. Specifically, excluded from this Warranty are failures caused by misuse, neglect, abuse, improper operation or filtration, extreme temperatures, or unauthorized service or parts. This Warranty also excludes the use of lubricants, fluids or air line additives that are not compatible with seals or diaphragms used in the products. This Warranty sets out the purchaser's exclusive remedies with respect to products covered by it, whether for negligence or otherwise. Neither, Bosch Rexroth nor any of its affiliates will be liable for consequential or incidental damages or other losses or expenses incurred by reason of the use or sale of such products.Our liability (except as to title) arising out of the sale, use or operation of any product or parts, whether on warranty, contract or negligence (including claims for consequential or incidental damage) shall not in any event exceed the cost of replacing the defective products and, upon expiration of the warranted period as herein provided, all such liability is terminated. THIS WARRANTY IS IN LIEU OF ALL OTHERWARRANTIES, EXPRESS OR IMPLIED, WHETHER FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE. No attempt to alter, amend or extend this Warranty shall be effective unless authorized in writing by an officer of Bosch Rexroth Corporation. Bosch Rexroth reserves the right to discontinue manufacture of any product, or change product materials, design or specifications without notice.

Page 14: CA44 Catalog

Printed in the United States

Dec. 2008 ©2008 Bosch Rexroth Corporation

Central

Bosch Rexroth Corporation

5150 Prairie Stone Parkway

Hoffman Estates, IL 60192-3707

Telephone (847) 645-3600

Facsimile (847) 645-0804

Great Lakes

Bosch Rexroth Corporation

1701 Harmon Road

Auburn Hills, MI 48326-1549

Telephone (248) 393-3330

Facsimile (248) 393-2893

Northeast

Bosch Rexroth Corporation

99 Rainbow Road

East Grandby, CT 06026-0000

Telephone (860) 844-8377

Facsimile (860) 844-8595

Bosch Rexroth Corporation

2315 City Line Road

Bethlehem, PA 18017-2131

Telephone (610) 694-8300

Facsimile (610) 694-8467

Southeast

Bosch Rexroth Corporation

14001 South Lake Drive

Charlotte, NC 28273-5544

Telephone (704) 583-4338

Facsimile (704) 583-0523

West

Bosch Rexroth Corporation

11 Goddard

Irvine, CA 92618-4600

Telephone (949) 450-2777

Facsimile (949) 450-2790

Asia:

China Russia

India Singapore

Japan South Korea

Malaysia

Australia

Europe:

Austria Netherlands

Belgium Norway

Bulgaria Poland

Czech Republic Portugal

Denmark Romania

Finland Slovakia

France Spain

Germany Sweden

Greece Switzerland

Hungary Turkey

Italy Ukraine

United Kingdom

North America:

Canada United States

Mexico

South America:

Argentina Venezuela

Brazil

Bosch Rexroth Corporation

Corporate Headquarters

5150 Prairie Stone Parkway

Hoffman Estates, IL 60192-3707

Telephone (847) 645-3600

Facsimile (847) 645-0804

Bosch Rexroth Corporation

Industrial Hydraulics

2315 City Line Road

Bethlehem, PA 18017-2131

Telephone (610) 694-8300

Facsimile (610) 694-8467

Bosch Rexroth Corporation

Electric Drives and Controls

5150 Prairie Stone Parkway

Hoffman Estates, IL 60192-3707

Telephone (847) 645-3600

Facsimile (847) 645-6201

Bosch Rexroth Corporation

Linear Motion and

Assembly Technologies

816 E. Third Street

Buchanan, MI 49107

Telephone (269) 695-0151

Facsimile (269) 695-5363

14001 South Lakes Drive

Charlotte, NC 28273

Telephone (800) 438-5983

Facsimile (704) 583-0523

Bosch Rexroth CorporationMobile Hydraulics145 Southchase BoulevardFountain Inn, SC 29644-9018Telephone (864) 967-2777Facsimile (864) 962-5338

The data specified herein only serves to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The given infor- mation does not release the user from obligation of own judgment and verification. It must be remem- bered that our products are sub- ject to a natural process of wear and aging. ©This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth Corp. Without their con- sent it may not be reproduced or given to third parties.

P L

Bosch Rexroth Canada 3426 Mainway Drive Burlington, Ontario L7M 1A8 Telephone (905) 335-5511 Facsimile (905) 335-4184 www.boschrexroth.ca Bosch Rexroth, S.A. de C.V. Calle Neptuno # 72 Unidad Industrial Vallejo CP 07700 Mexico, D.F. Telephone (555) 754-1711 Facsimile (555) 752-5943 Further contacts: www.boschrexroth.com/addresses

North American offices: International offices: Factory Automation Regional sales offices:

Bosch Rexroth Corporation Pneumatics 1953 Mercer Road Lexington, KY 40511-1021 Telephone (859) 254-8031 Facsimile (859) 254-4188 [email protected] www.boschrexroth-us.com