C575U Repair manual (electron) (E) - SportsArt...Troubleshooting Model: C575U Malfunction: Unit will...
Transcript of C575U Repair manual (electron) (E) - SportsArt...Troubleshooting Model: C575U Malfunction: Unit will...
C575U Repair Manual (Electronics)
1-1. Product Picture -C575U
1-1-1
1-2. Display picture -C575U
1-2-1
1-3. Component Placement - C575U Display
1-3-1
Dispaly
Program board Polar board
USB board
1-3.Component placement- C575U lower body
1-3-2
Battery *1
Speed sensor
Drive board
Electro-magnet
Alternator
Battery *1
Model board
1-3. Component placement- C575U lower body - C575U
1-3-2
Battery *1
Electro-magnet
Model board
Alternator
1-4. Block Diagram - C575U Electronics
1-4-1
Display Board
Drive Board
Electronic Magnet
Speed Sensor
Charger
Alternator
keypad
USB Board
HR receiver
C-SAFE Board
Battery
Model board
Fan
HTR board S
ensor-R
Sensor-L
1-5.接線示意圖-C575U
1-5. Connections - C575R/U Display
1-5-1
Program board To soft key
To USB board
To Polar board
To Fan
To HTR board
To USB & CSAFE
To Drive board
To USB board
1-5. Connections - C575R/U Display
1-5-2
USB board
To Display
To program board ( upgrade program)
To blue-tooth key
To Display
1-5. Connections - C575R/U Display
1-5-3
To Electro-magnet
To battery
To display
To Alternator & Battery charger
To Speed sensor
To Model board
1-6. Display Board Indicator LEDs – C575R/U
1-6-1
Power
1-6.Drive Board Indicator LEDs – C575R/U
1-6-2
F1 Alternator fuse 3A
LED 5 COMM �Communication indicator
F3 battery charged fuse �2A
F2 Battery fuse �2A
LED 3 VBB � Lit = Vbb power indicator
LED 4 HTR (C575R) �Lit, HTR indicator
LED 1 CLK �Speed sensor indicator
LED 6 VCC power �Lit, Vcc power indicator
LED 2 Battery charge �Lit, Battery is being charged.
Program
TroubleshootingTroubleshootingTroubleshootingTroubleshooting
Model: C575U Malfunction: Unit will not start (alternator). Circumstance: Start pedaling; the display shows no reaction. Possible reasons: 1. Wires are not connected. 2. The drive board fuse has blown. Troubleshooting: 1. Inspect wire and data cable connections. 2. Inspect the alternator. Do LED3 and LED6 on the drive board light when you pedal? 3. Inspect whether F2 fuse on the drive board is burnt. 4. Replace the drive board as a test. 5. Inspect the display power LED and main program IC.
3-1-1
Drive Board
Display board
Alternator Alternator fuse 3A
Alternator
Display
TroubleshootingTroubleshootingTroubleshootingTroubleshooting
Model: C575U Malfunction: Unit will not start (battery). Circumstance: When I stop pedaling, the display turns off. Possible causes: 1. The battery fuse on the drive board is burnt. 2. The battery power is too low because the bike has been out of use. 3. The battery charge function on drive board has failed. Troubleshooting: 1. Inspect wire and data cable connections. 2. Measure the battery voltage. Normal: 5.2V or more. 3. Inspect F1 fuse on the drive board. Or replace the drive board as a test. 4. Pedal at 50 RPM or higher to recharge the battery.
3-1-2
Drive Board
Display board
Battery 6V*2
Fuse
LED 6 Vcc
Battery 6V
Battery fuse 2A
LED 3 Vbb
Battery 6V
TroubleshootingTroubleshootingTroubleshootingTroubleshooting
Model: C570R Malfunction: No RPM value appears. Circumstance: I pedal on the bike but no RPM value appears. Possible causes: 1. Wires are not connected. 2. Speed sensor is malfunctioning. Troubleshooting: 1. Make sure the distance between the optic sensor and the reflective sticker is 3-8mm. 2. Make sure the sensor on the optic sensor board is clean. 3. Inspect the drive board. 4. Inspect all cable connections.
3-2-1
Drive Board
Display board
Sensor / reflective
sticker
Speed sensor LED 1
故障排除
機 種 C575U
故障項目 無阻力
故障情形 踩踏機台,無任何阻力
可能原因 1.電子表無 RPM 信號
2.驅動板不良
故障排除 1.檢查驅動板 CLK 信號燈
2.檢查所有排線是否接好
3.檢查發電機電壓是否正常
4.量測阻力電壓輸出?或更換驅動板
5.檢查驅動板 LED3,LED4 電磁鐵接線是否正常
6.鑄鋼輪組單向軸承損壞
3-3-1
Drive Board
Display board
Speed Sensor
Electronic Magnet
Alternator
Speed sensor
Blue-blue Level voltage(V)
LEVEL 1 1.9 V
LEVEL 10 11 V
LEVEL 40 17 V
Alternator
Electro-magnet
TroubleshootingTroubleshootingTroubleshootingTroubleshooting
Model: C575R Malfunction: No resistance. Circumstance: I pedal on the bike, but there is no resistance. Possible causes: 1. Display has no RPM value. 2. There is no output voltage from the alternator. 3. Drive board is defective. Troubleshooting: 1. Inspect whether the display receives the RPM signal. 2. Inspect whether the alternator can start the unit. 3. Inspect all cable connections. 4. Inspect the F2 fuse on the drive board. Measure alternator output voltage. Or replace the drive board as a test. 5. Inspect electro-magnet wire connections.
3-3-2
Drive Board
Display board
Electronic Magnet
Speed sensor
Speed sensor
Blue-blue Level voltage(V)
LEVEL 1 3 v
LEVEL 10 11 v
LEVEL 20 18 v
Alternator
Electronic-magnet
TroubleshootingTroubleshootingTroubleshootingTroubleshooting Model: C575R Malfunction: No telemetry heart rate reception. Circumstance: I am wearing the heart rate telemetry strap properly. But there is no heart rate reading. Possible causes: 1. Telemetry strap transmitter battery voltage is too low. 2. Heart rate telemetry receiver board is malfunctioning. 3. Environmental interference, for instance, from lights or speakers, impedes signal reception. Troubleshooting: 1. Replace the telemetry strap or its batteries. 2. Inspect the telemetry heart rate receiver board wire connections. 3. Replace the heart rate receiver board.
3-4-1
Display board
Transmitter
Polar board
Polar board
Polar T34
TroubleshootingTroubleshootingTroubleshootingTroubleshooting Model: C575R Malfunction: Contact heart rate (HTR) malfunction. Circumstance: Hold HTR contact plates; heart rate value is incorrect. Possible causes: 1. HTR wires are disconnected. 2. HTR board is defective. Troubleshooting: 1. Inspect display wire connections. 2. Inspect the HTR wire on the drive board. 3. Inspect the HTR bridge board and HTR board indicator LEDs. 4. Inspect the HTR contacts and their wire connections.
3-4-2
Display board
HTR board
Sensor-R
Sensor-L
HTR board indicator LEDs LED Name Explanation
LED1 Telemetry Flashes to indicate incoming telemetry signal. LED2 HTR contact Lights to indicate hands on contact plates. LED3 HTR output Flashes to indicate incoming HTR (contact)
signal. LED4 Heart rate
signal output Flashes to indicate heart rate signal output to the display
TroubleshootingTroubleshootingTroubleshootingTroubleshooting Model: C575R/U Malfunction: Soft keys do not function. Circumstance: Press the soft keys. There is no response. Or the keys operate continuously. Possible causes: 1. Soft keys are not functioning. Troubleshooting: 1. Replace soft keys.
3-5-1
Display board
Soft key
Soft key
TroubleshootingTroubleshootingTroubleshootingTroubleshooting
Model: C575R/U Malfunction: Display key switch malfunction. Circumstance: Press display keys, for instance, <STOP>,LEVEL <▲> / <▼>. There is no reaction, or keys operate continuously. Possible causes: 1. Display key malfunction. 2. Key cushions are out of place. Troubleshooting: 1. Inspect key switch cushions. 2. Replace key switches.
3-5-2
Tack switch
Tack switch cushions
Tack switch
TroubleshootingTroubleshootingTroubleshootingTroubleshooting
Model: C570R Malfunction: Fan does not operate. Malfunction: Press the fan key; the fan does not operate. Possible causes: 1. Pedal rotation speed is below 50 RPM. 2. Fan motor is defective. Troubleshooting: 1. Inspect whether speed exceeds 50 RPM. 2. Inspect wire connections from the display to the fan board. 3. Test whether the display sends voltage to the fan board. If the display board does not send voltage to the fan board, replace the display. If the display board sends voltage to the fan board, but the fan board doesn’t operate, replace the fan board.
3-6-1
Display board
Fan
key
Fan motor
Fan Voltage(V) Fan low 3 v Fan mid 6v Fan high 9v
其他說明
機 種 C575
項 目 機型小板說明
功 能 1.設定機種別,以利程式判斷機種
2.C575,E875 的控制板及程式小板共用,機型小板作為判斷機種用
說 明
3-11-1
機種 JP1,JP2,JP3,JP4,….JP16
C575R/U JP2 跳線,其他 JP1,JP3-JP16 斷路