C Staad.foundation 4 CalcXsl Footing

73
Isolated Footing Design Design For Isolated Footing 1 Design For Isolated Footing 2 Design For Isolated Footing 3 Design For Isolated Footing 4 Design For Isolated Footing 5 Design For Isolated Footing 6 Design For Isolated Footing 7 Design For Isolated Footing 8 Design For Isolated Footing 9 Design For Isolated Footing 10 Design For Isolated Footing 11 Design For Isolated Footing 12 Isolated Footing 1 Input Values Concrete and Rebar Properties Concrete Covers Soil Properties Geometry Unit Weight of Concrete : 24.000 kN/m3 Strength of Concrete : 25.000 N/mm2 Yield Strength of Steel : 415.000 N/mm2 Minimum Bar Size : # 6 Maximum Bar Size : # 18 Minimum Bar Spacing : 50.00 mm Maximum Bar Spacing : 250.00 mm Pedestal Clear Cover (P, CL) : 0.00 (null) Footing Clear Cover (F, CL) : 50.00 mm Unit Weight : 20.00 kN/m3 Soil Bearing Capacity : 300.00 kN/mm2 Soil Surcharge : 0.00 kN/mm2 Depth of Soil above Footing : 900.00 mm Page 1 of 73 Isolated Footing Design 3/17/2013 file://C:\Staad.foundation 4\CalcXsl\footing.xml

description

Staad Footing Design

Transcript of C Staad.foundation 4 CalcXsl Footing

Page 1: C Staad.foundation 4 CalcXsl Footing

Isolated Footing Design Design For Isolated Footing 1

Design For Isolated Footing 2

Design For Isolated Footing 3

Design For Isolated Footing 4

Design For Isolated Footing 5

Design For Isolated Footing 6

Design For Isolated Footing 7

Design For Isolated Footing 8

Design For Isolated Footing 9

Design For Isolated Footing 10

Design For Isolated Footing 11

Design For Isolated Footing 12

Isolated Footing 1

Input Values

Concrete and Rebar Properties

Concrete Covers

Soil Properties

Geometry

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Page 1 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 2: C Staad.foundation 4 CalcXsl Footing

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Final dimensions for design.

Calculated pressures at 4 corners.

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.002 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 41.34 in Governing Load Case : # 5

Width (W2) = 41.34 in Governing Load Case : # 5

Area (A2) = 1708.88 in2

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

8 0.06 0.02 0.03 0.07 -0.00

6 0.05 0.04 0.04 0.05 -0.00

6 0.05 0.04 0.04 0.05 -0.00

8 0.06 0.02 0.03 0.07 -0.00

Page 2 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 3: C Staad.foundation 4 CalcXsl Footing

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Critical load case and the governing factor of safety for overturning and sliding

Critical load case and the governing factor of safety for overturning and sliding

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

8 0.06 0.02 0.03 0.07

6 0.05 0.04 0.04 0.05

6 0.05 0.04 0.04 0.05

8 0.06 0.02 0.03 0.07

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 220.758 47.627 45.679 256.940

6 38.671 22.871 132.005 22.643

7 30.484 16.548 68.609 17.717

8 12.953 294.479 57.042 6.708

9 10.233 19033.158 57.044 5.286

Critical Load Case for Sliding along X-Direction : 9

Governing Disturbing Force : -3.016 kip

Governing Restoring Force : 30.861 kip

Minimum Sliding Ratio for the Critical Load Case : 10.233

Critical Load Case for Overturning about X-Direction :

5

Governing Overturning Moment : -28.997 kip-in

Governing Resisting Moment : 1324.571 kip-in

Minimum Overturning Ratio for the Critical Load Case :

45.679

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : 0.002 kip

Governing Restoring Force : 29.800 kip

Minimum Sliding Ratio for the Critical Load Case : 16.548

Critical Load Case for Overturning about Z-Direction :

9

Governing Overturning Moment : 241.346 kip-in

Governing Resisting Moment : 1275.754 kip-

Page 3 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 4: C Staad.foundation 4 CalcXsl Footing

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = 33.65 kip, Load Case # 5

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

in

Minimum Overturning Ratio for the Critical Load Case :

5.286

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along Z to design for shear, Dz = 41.32 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vux is # 5 0.02 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along X to design for shear, Dx = 0.02 in

Page 4 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 5: C Staad.foundation 4 CalcXsl Footing

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vuz is # 5 0.02 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 14.76 in

Ultimate moment, 152.60 kip-in

Nominal moment capacity, Mn = 169.55 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.10 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Page 5 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 6: C Staad.foundation 4 CalcXsl Footing

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Reinforcement ratio, = 0.00346

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 26.57 in

Ultimate moment, 159.56 kip-in

Nominal moment capacity, Mn = 177.29 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.04 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Page 6 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 7: C Staad.foundation 4 CalcXsl Footing

Check to see if width is sufficient to accomodate bars

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00384

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Isolated Footing 2

Input Values

Concrete and Rebar Properties

Concrete Covers

Soil Properties

Geometry

Initial Footing Dimensions

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Page 7 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 8: C Staad.foundation 4 CalcXsl Footing

Pedestal

Footing Design Calculations

Footing Size

Final dimensions for design.

Calculated pressures at 4 corners.

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.002 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 41.34 in Governing Load Case : # 5

Width (W2) = 41.34 in Governing Load Case : # 5

Area (A2) = 1708.88 in2

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

8 0.06 0.01 0.03 0.08 -0.00

5 0.05 0.05 0.05 0.05 -0.00

6 0.04 0.03 0.06 0.07 -0.00

8 0.06 0.01 0.03 0.08 -0.00

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

8 0.06 0.01 0.03 0.08

5 0.05 0.05 0.05 0.05

Page 8 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 9: C Staad.foundation 4 CalcXsl Footing

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Critical load case and the governing factor of safety for overturning and sliding

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

6 0.04 0.03 0.06 0.07

8 0.06 0.01 0.03 0.08

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 844.906 40.438 37.312 2377.765

6 36.627 25.180 10.102 23.655

7 28.140 22.295 8.133 17.900

8 8.659 27.983 16.978 5.262

9 6.273 24.927 14.098 3.796

Critical Load Case for Sliding along X-Direction : 9

Governing Disturbing Force : -4.358 kip

Governing Restoring Force : 27.337 kip

Minimum Sliding Ratio for the Critical Load Case : 6.273

Critical Load Case for Overturning about X-Direction :

7

Governing Overturning Moment : -160.457 kip-in

Governing Resisting Moment : 1304.925 kip-in

Minimum Overturning Ratio for the Critical Load Case :

8.133

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : -1.097 kip

Governing Restoring Force : 31.567 kip

Minimum Sliding Ratio for the Critical Load Case : 22.295

Critical Load Case for Overturning about Z-Direction :

9

Governing Overturning Moment : 297.684 kip-in

Governing Resisting Moment : 1130.080 kip-in

Minimum Overturning Ratio for the Critical Load Case :

3.796

Page 9 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 10: C Staad.foundation 4 CalcXsl Footing

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = 45.31 kip, Load Case # 5

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along Z to design for shear, Dz = 41.32 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vux is # 5 0.03 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along X to design for shear, Dx = 0.02 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vuz is # 5 0.03 kip

0.75 * Vc > Vuz hence, OK

Page 10 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 11: C Staad.foundation 4 CalcXsl Footing

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 14.76 in

Ultimate moment, 203.63 kip-in

Nominal moment capacity, Mn = 226.25 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.10 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00346

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Page 11 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 12: C Staad.foundation 4 CalcXsl Footing

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 26.57 in

Ultimate moment, 216.99 kip-in

Nominal moment capacity, Mn = 241.10 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.04 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00384

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 9.16 in

Page 12 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 13: C Staad.foundation 4 CalcXsl Footing

Check to see if width is sufficient to accomodate bars

distance between bars, Cd = User Spacing) =

Isolated Footing 3

Input Values

Concrete and Rebar Properties

Concrete Covers

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Page 13 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 14: C Staad.foundation 4 CalcXsl Footing

Footing Design Calculations

Footing Size

Final dimensions for design.

Calculated pressures at 4 corners.

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.001 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 45.28 in Governing Load Case : # 5

Width (W2) = 45.28 in Governing Load Case : # 5

Area (A2) = 2049.88 in2

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

9 0.02 -0.01 -0.01 0.02 495.25

5 0.02 0.02 0.02 0.02 -0.00

6 0.02 0.01 0.03 0.04 -0.00

6 0.02 0.01 0.03 0.04 -0.00

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

9 0.03 0.00 0.00 0.03

5 0.02 0.02 0.02 0.02

6 0.02 0.01 0.03 0.04

6 0.02 0.01 0.03 0.04

Page 14 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 15: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = 22.06 kip, Load Case # 5

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 59.356 23.377 21.669 56.269

6 37.433 7.693 9.067 19.588

7 28.547 6.149 7.108 15.683

8 4.253 28.069 45.376 2.276

9 2.845 12.324 15.564 1.542

Critical Load Case for Sliding along X-Direction : 9

Governing Disturbing Force : -2.752 kip

Governing Restoring Force : 7.828 kip

Minimum Sliding Ratio for the Critical Load Case : 2.845

Critical Load Case for Overturning about X-Direction :

7

Governing Overturning Moment : 134.537 kip-in

Governing Resisting Moment : 956.269 kip-in

Minimum Overturning Ratio for the Critical Load Case :

7.108

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : 0.635 kip

Governing Restoring Force : 21.121 kip

Minimum Sliding Ratio for the Critical Load Case : 6.149

Critical Load Case for Overturning about Z-Direction :

9

Governing Overturning Moment : 229.900 kip-in

Governing Resisting Moment : 354.397 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.542

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

Page 15 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 16: C Staad.foundation 4 CalcXsl Footing

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 80.42 kip

Distance along Z to design for shear, Dz = 43.29 in

From above calculations, 0.75 * Vc = 60.31 kip

Critical load case for Vux is # 5 1.72 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 80.42 kip

Distance along X to design for shear, Dx = 1.98 in

From above calculations, 0.75 * Vc = 60.31 kip

Critical load case for Vuz is # 5 1.57 kip

0.75 * Vc > Vuz hence, OK

Page 16 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 17: C Staad.foundation 4 CalcXsl Footing

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 16.73 in

Ultimate moment, 109.20 kip-in

Nominal moment capacity, Mn = 121.33 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.20 sq.in

Available development length for bars, DL = 14.76 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00316

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

10.15 in

Page 17 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 18: C Staad.foundation 4 CalcXsl Footing

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 28.54 in

Ultimate moment, 117.52 kip-in

Nominal moment capacity, Mn = 130.57 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.14 sq.in

Available development length for bars, DL = 14.76 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 6

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.64 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00420

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

8.12 in

Page 18 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 19: C Staad.foundation 4 CalcXsl Footing

Isolated Footing 4

Input Values

Concrete and Rebar Properties

Concrete Covers

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Page 19 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 20: C Staad.foundation 4 CalcXsl Footing

Final dimensions for design.

Calculated pressures at 4 corners.

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Min. area required from bearing pressure, Amin = P / qmax = 0.003 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 41.34 in Governing Load Case : # 5

Width (W2) = 41.34 in Governing Load Case : # 5

Area (A2) = 1708.88 in2

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

7 0.06 0.06 0.06 0.07 -0.00

7 0.06 0.06 0.06 0.07 -0.00

8 -0.03 -0.07 0.17 0.22 325.37

8 -0.03 -0.07 0.17 0.22 325.37

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

7 0.06 0.06 0.06 0.07

7 0.06 0.06 0.06 0.07

8 0.00 0.00 0.19 0.25

8 0.00 0.00 0.19 0.25

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 1.820 14.804 1.838 13.859

6 2.795 3.220 7.678 71.948

Page 20 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 21: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = 35.01 kip, Load Case # 5

7 3.596 2.462 48.115 103.979

8 2.630 31.618 1.857 10.807

9 3.287 17.656 1.874 11.230

Critical Load Case for Sliding along X-Direction : 5

Governing Disturbing Force : -28.089 kip

Governing Restoring Force : 51.114 kip

Minimum Sliding Ratio for the Critical Load Case : 1.820

Critical Load Case for Overturning about X-Direction :

5

Governing Overturning Moment : 1149.812 kip-in

Governing Resisting Moment : 2112.967 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.838

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : -2.853 kip

Governing Restoring Force : 51.848 kip

Minimum Sliding Ratio for the Critical Load Case : 2.462

Critical Load Case for Overturning about Z-Direction :

8

Governing Overturning Moment : 243.471 kip-in

Governing Resisting Moment : 2631.092 kip-in

Minimum Overturning Ratio for the Critical Load Case :

10.807

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Page 21 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 22: C Staad.foundation 4 CalcXsl Footing

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along Z to design for shear, Dz = 41.32 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vux is # 5 0.08 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along X to design for shear, Dx = 0.02 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vuz is # 5 0.05 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

Page 22 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 23: C Staad.foundation 4 CalcXsl Footing

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 14.76 in

Ultimate moment, 297.13 kip-in

Nominal moment capacity, Mn = 330.14 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.10 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00346

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

Page 23 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 24: C Staad.foundation 4 CalcXsl Footing

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 26.57 in

Ultimate moment, 653.25 kip-in

Nominal moment capacity, Mn = 725.83 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.04 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00384

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Isolated Footing 5

Input Values

Page 24 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 25: C Staad.foundation 4 CalcXsl Footing

Concrete and Rebar Properties

Concrete Covers

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.003 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Page 25 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 26: C Staad.foundation 4 CalcXsl Footing

Final dimensions for design.

Calculated pressures at 4 corners.

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Length (L2) = 49.21 in Governing Load Case : # 5

Width (W2) = 49.21 in Governing Load Case : # 5

Area (A2) = 2421.88 in2

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

5 0.18 -0.06 -0.06 0.19 581.25

9 0.03 0.03 0.04 0.04 0.00

9 0.03 0.03 0.04 0.04 0.00

5 0.18 -0.06 -0.06 0.19 581.25

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

5 0.24 0.00 0.00 0.24

9 0.03 0.03 0.04 0.04

9 0.03 0.03 0.04 0.04

5 0.24 0.00 0.00 0.24

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 3.438 105.421 78.757 1.517

6 4.485 25.078 9.288 2.101

7 5.359 19.993 6.693 2.814

8 11.123 84.670 28.028 4.096

9 51.112 129.719 23.855 132.927

Page 26 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 27: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = -58.24 kip, Load Case # 5

Critical Load Case for Sliding along X-Direction : 5

Governing Disturbing Force : 21.634 kip

Governing Restoring Force : 74.384 kip

Minimum Sliding Ratio for the Critical Load Case : 3.438

Critical Load Case for Overturning about X-Direction :

7

Governing Overturning Moment : -318.094 kip-in

Governing Resisting Moment : 2129.055 kip-in

Minimum Overturning Ratio for the Critical Load Case :

6.693

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : -0.313 kip

Governing Restoring Force : 43.262 kip

Minimum Sliding Ratio for the Critical Load Case : 19.993

Critical Load Case for Overturning about Z-Direction :

5

Governing Overturning Moment : -2413.650 kip-in

Governing Resisting Moment : 3660.649 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.517

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

Page 27 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 28: C Staad.foundation 4 CalcXsl Footing

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

From ACI Cl.11.3.1.1, Vc = 87.41 kip

Distance along Z to design for shear, Dz = 45.26 in

From above calculations, 0.75 * Vc = 65.56 kip

Critical load case for Vux is # 5 11.51 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 87.41 kip

Distance along X to design for shear, Dx = 3.95 in

From above calculations, 0.75 * Vc = 65.56 kip

Critical load case for Vuz is # 5 45.94 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Page 28 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 29: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 18.70 in

Ultimate moment, 1594.46 kip-in

Nominal moment capacity, Mn = 1771.62 kip-in

Required = 0.00283

Since OK

Area of Steel Required, As = 2.05 sq.in

Available development length for bars, DL = 16.73 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 6

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.64 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00349

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

8.91 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Page 29 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 30: C Staad.foundation 4 CalcXsl Footing

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 30.51 in

Ultimate moment, 509.74 kip-in

Nominal moment capacity, Mn = 566.38 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.24 sq.in

Available development length for bars, DL = 16.73 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 6

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.64 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00387

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

8.91 in

Isolated Footing 6

Input Values

Concrete and Rebar Properties

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Page 30 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 31: C Staad.foundation 4 CalcXsl Footing

Concrete Covers

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Final dimensions for design.

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.004 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 53.15 in Governing Load Case : # 9

Width (W2) = 53.15 in Governing Load Case : # 9

Area (A2) = 2824.88 in2

Page 31 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 32: C Staad.foundation 4 CalcXsl Footing

Calculated pressures at 4 corners.

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Critical load case and the governing factor of safety for overturning and sliding

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

6 0.09 -0.07 0.02 0.17 501.70

5 0.05 -0.13 0.07 0.25 659.89

5 0.05 -0.13 0.07 0.25 659.89

5 0.05 -0.13 0.07 0.25 659.89

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

6 0.08 0.00 0.00 0.21

5 0.00 0.00 0.01 0.40

5 0.00 0.00 0.01 0.40

5 0.00 0.00 0.01 0.40

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 13.717 9.318 1.798 2.031

6 99.532 4.773 3.502 2.007

7 15.949 2.771 7.619 2.107

8 9.633 339.089 2.161 1.612

9 4.308 13.476 2.708 1.503

Critical Load Case for Sliding along X-Direction : 9

Governing Disturbing Force : -8.727 kip

Governing Restoring Force : 37.592 kip

Page 32 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 33: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = -136.47 kip, Load Case # 5

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Minimum Sliding Ratio for the Critical Load Case : 4.308

Critical Load Case for Overturning about X-Direction :

5

Governing Overturning Moment : 2490.895 kip-in

Governing Resisting Moment : 4479.174 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.798

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : -2.790 kip

Governing Restoring Force : 49.787 kip

Minimum Sliding Ratio for the Critical Load Case : 2.771

Critical Load Case for Overturning about Z-Direction :

9

Governing Overturning Moment : 1329.668 kip-in

Governing Resisting Moment : 1997.987 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.503

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

Page 33 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 34: C Staad.foundation 4 CalcXsl Footing

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

From ACI Cl.11.3.1.1, Vc = 94.40 kip

Distance along Z to design for shear, Dz = 47.23 in

From above calculations, 0.75 * Vc = 70.80 kip

Critical load case for Vux is # 5 56.36 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 94.40 kip

Distance along X to design for shear, Dx = 5.92 in

From above calculations, 0.75 * Vc = 70.80 kip

Critical load case for Vuz is # 5 49.34 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 20.67 in

Ultimate moment, 1512.88 kip-in

Nominal moment capacity, Mn = 1680.98 kip-in

Page 34 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 35: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Required = 0.00248

Since OK

Area of Steel Required, As = 1.94 sq.in

Available development length for bars, DL = 18.70 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 6

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.64 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00323

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.69 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Page 35 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 36: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 32.48 in

Ultimate moment, 1685.67 kip-in

Nominal moment capacity, Mn = 1872.97 kip-in

Required = 0.00308

Since OK

Area of Steel Required, As = 2.29 sq.in

Available development length for bars, DL = 18.70 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 6

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.64 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00358

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.69 in

Isolated Footing 7

Input Values

Concrete and Rebar Properties

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Page 36 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 37: C Staad.foundation 4 CalcXsl Footing

Concrete Covers

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Final dimensions for design.

Calculated pressures at 4 corners.

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.003 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 74.80 in Governing Load Case : # 5

Width (W2) = 74.80 in Governing Load Case : # 5

Area (A2) = 5595.51 in2

Page 37 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 38: C Staad.foundation 4 CalcXsl Footing

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Critical load case and the governing factor of safety for overturning and sliding

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

5 0.01 0.01 0.04 0.04 0.00

5 0.01 0.01 0.04 0.04 0.00

6 -0.01 -0.01 0.05 0.05 1038.53

6 -0.01 -0.01 0.05 0.05 1038.53

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

5 0.01 0.01 0.04 0.04

5 0.01 0.01 0.04 0.04

6 0.00 0.00 0.06 0.06

6 0.00 0.00 0.06 0.06

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 2.208 23.642 5.154 156.915

6 2.402 2.170 1.912 188.181

7 3.010 1.532 1.500 101.020

8 2.686 6.041 2.807 58.234

9 3.363 4.853 2.473 46.919

Critical Load Case for Sliding along X-Direction : 5

Governing Disturbing Force : -33.794 kip

Governing Restoring Force : 74.628 kip

Minimum Sliding Ratio for the Critical Load Case : 2.208

Critical Load Case for Overturning about X-Direction :

7

Page 38 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 39: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = 110.33 kip, Load Case # 5

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Governing Overturning Moment : -2002.888 kip-in

Governing Resisting Moment : 3005.079 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.500

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : -11.511 kip

Governing Restoring Force : 40.173 kip

Minimum Sliding Ratio for the Critical Load Case : 1.532

Critical Load Case for Overturning about Z-Direction :

9

Governing Overturning Moment : 89.071 kip-in

Governing Resisting Moment : 4179.113 kip-in

Minimum Overturning Ratio for the Critical Load Case :

46.919

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 132.86 kip

Page 39 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 40: C Staad.foundation 4 CalcXsl Footing

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Distance along Z to design for shear, Dz = 58.06 in

From above calculations, 0.75 * Vc = 99.65 kip

Critical load case for Vux is # 5 43.36 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 132.86 kip

Distance along X to design for shear, Dx = 16.75 in

From above calculations, 0.75 * Vc = 99.65 kip

Critical load case for Vuz is # 5 28.76 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 31.50 in

Ultimate moment, 850.72 kip-in

Nominal moment capacity, Mn = 945.25 kip-in

Page 40 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 41: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Required = 0.00180

Since OK

Area of Steel Required, As = 1.99 sq.in

Available development length for bars, DL = 29.53 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 8

Total reinforcement area, As_total = Nbar * (Area of one bar) = 3.52 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00306

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

10.02 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 43.31 in

Page 41 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 42: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Ultimate moment, 1251.84 kip-in

Nominal moment capacity, Mn = 1390.93 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.88 sq.in

Available development length for bars, DL = 29.53 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 8

Total reinforcement area, As_total = Nbar * (Area of one bar) = 3.52 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00339

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

10.02 in

Isolated Footing 8

Input Values

Concrete and Rebar Properties

Concrete Covers

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Page 42 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 43: C Staad.foundation 4 CalcXsl Footing

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Final dimensions for design.

Calculated pressures at 4 corners.

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.004 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 46.26 in Governing Load Case : # 5

Width (W2) = 46.26 in Governing Load Case : # 5

Area (A2) = 2139.97 in2

Page 43 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 44: C Staad.foundation 4 CalcXsl Footing

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Critical load case and the governing factor of safety for overturning and sliding

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

5 0.23 -0.08 -0.07 0.24 513.59

9 0.04 0.03 0.04 0.05 -0.00

9 0.04 0.03 0.04 0.05 -0.00

5 0.23 -0.08 -0.07 0.24 513.59

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

5 0.31 0.00 0.00 0.32

9 0.04 0.03 0.04 0.05

9 0.04 0.03 0.04 0.05

5 0.31 0.00 0.00 0.32

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 3.049 93.778 69.397 1.513

6 4.331 87.587 12.551 1.997

7 6.124 32.774 6.845 2.789

8 8.301 17282.154 54.665 3.655

9 111.909 93.792 23.476 217.227

Critical Load Case for Sliding along X-Direction : 5

Governing Disturbing Force : 27.841 kip

Governing Restoring Force : 84.891 kip

Minimum Sliding Ratio for the Critical Load Case : 3.049

Critical Load Case for Overturning about X-Direction :

7

Page 44 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 45: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = -43.87 kip, Load Case # 5

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Governing Overturning Moment : -267.378 kip-in

Governing Resisting Moment : 1830.075 kip-in

Minimum Overturning Ratio for the Critical Load Case :

6.845

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : -0.456 kip

Governing Restoring Force : 39.561 kip

Minimum Sliding Ratio for the Critical Load Case : 32.774

Critical Load Case for Overturning about Z-Direction :

5

Governing Overturning Moment : -2594.835 kip-in

Governing Resisting Moment : 3927.062 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.513

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 82.16 kip

Page 45 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 46: C Staad.foundation 4 CalcXsl Footing

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Distance along Z to design for shear, Dz = 43.78 in

From above calculations, 0.75 * Vc = 61.62 kip

Critical load case for Vux is # 5 8.94 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 82.16 kip

Distance along X to design for shear, Dx = 2.48 in

From above calculations, 0.75 * Vc = 61.62 kip

Critical load case for Vuz is # 5 35.56 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 17.22 in

Ultimate moment, 1648.37 kip-in

Nominal moment capacity, Mn = 1831.52 kip-in

Page 46 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 47: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Required = 0.00312

Since OK

Area of Steel Required, As = 2.13 sq.in

Available development length for bars, DL = 15.26 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00309

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

10.39 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 29.04 in

Page 47 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 48: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Ultimate moment, 535.58 kip-in

Nominal moment capacity, Mn = 595.09 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.17 sq.in

Available development length for bars, DL = 15.26 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 6

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.64 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00411

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

8.31 in

Isolated Footing 9

Input Values

Concrete and Rebar Properties

Concrete Covers

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Page 48 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 49: C Staad.foundation 4 CalcXsl Footing

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Final dimensions for design.

Calculated pressures at 4 corners.

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.004 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 68.90 in Governing Load Case : # 7

Width (W2) = 68.90 in Governing Load Case : # 7

Area (A2) = 4746.88 in2

Page 49 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 50: C Staad.foundation 4 CalcXsl Footing

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Critical load case and the governing factor of safety for overturning and sliding

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

5 0.05 -0.05 0.04 0.14 736.72

5 0.05 -0.05 0.04 0.14 736.72

5 0.05 -0.05 0.04 0.14 736.72

6 0.02 -0.06 0.04 0.13 1070.90

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

5 0.04 0.00 0.03 0.16

5 0.04 0.00 0.03 0.16

5 0.04 0.00 0.03 0.16

6 0.00 0.00 0.02 0.19

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 16.964 13.858 2.773 2.558

6 71.260 2.671 1.806 2.250

7 13.583 1.787 1.526 2.247

8 12.428 6.100 2.477 2.063

9 5.372 4.475 2.416 1.956

Critical Load Case for Sliding along X-Direction : 9

Governing Disturbing Force : -8.160 kip

Governing Restoring Force : 43.836 kip

Minimum Sliding Ratio for the Critical Load Case : 5.372

Critical Load Case for Overturning about X-Direction :

7

Page 50 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 51: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = 98.46 kip, Load Case # 5

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Governing Overturning Moment : -2087.905 kip-in

Governing Resisting Moment : 3185.228 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.526

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : -9.797 kip

Governing Restoring Force : 46.231 kip

Minimum Sliding Ratio for the Critical Load Case : 1.787

Critical Load Case for Overturning about Z-Direction :

9

Governing Overturning Moment : 1544.292 kip-in

Governing Resisting Moment : 3020.214 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.956

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 122.37 kip

Page 51 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 52: C Staad.foundation 4 CalcXsl Footing

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Distance along Z to design for shear, Dz = 55.10 in

From above calculations, 0.75 * Vc = 91.78 kip

Critical load case for Vux is # 5 74.53 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 122.37 kip

Distance along X to design for shear, Dx = 13.80 in

From above calculations, 0.75 * Vc = 91.78 kip

Critical load case for Vuz is # 5 78.43 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 28.54 in

Ultimate moment, 2164.66 kip-in

Nominal moment capacity, Mn = 2405.17 kip-in

Page 52 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 53: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Required = 0.00274

Since OK

Area of Steel Required, As = 2.78 sq.in

Available development length for bars, DL = 26.57 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 8

Total reinforcement area, As_total = Nbar * (Area of one bar) = 3.52 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00332

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.17 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 40.35 in

Page 53 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 54: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Ultimate moment, 2071.13 kip-in

Nominal moment capacity, Mn = 2301.25 kip-in

Required = 0.00291

Since OK

Area of Steel Required, As = 2.81 sq.in

Available development length for bars, DL = 26.57 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 8

Total reinforcement area, As_total = Nbar * (Area of one bar) = 3.52 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00368

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.17 in

Isolated Footing 10

Input Values

Concrete and Rebar Properties

Concrete Covers

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Page 54 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 55: C Staad.foundation 4 CalcXsl Footing

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Final dimensions for design.

Calculated pressures at 4 corners.

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.001 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 56.10 in Governing Load Case : # 9

Width (W2) = 56.10 in Governing Load Case : # 9

Area (A2) = 3147.48 in2

Page 55 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 56: C Staad.foundation 4 CalcXsl Footing

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Critical load case and the governing factor of safety for overturning and sliding

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

5 0.02 0.02 0.02 0.02 0.00

5 0.02 0.02 0.02 0.02 0.00

5 0.02 0.02 0.02 0.02 0.00

9 0.01 -0.01 0.00 0.01 795.68

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

5 0.02 0.02 0.02 0.02

5 0.02 0.02 0.02 0.02

5 0.02 0.02 0.02 0.02

9 0.00 0.00 0.00 0.02

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 655.478 1029.548 308.514 240.887

6 21.692 4.945 6.615 723.421

7 12.651 2.885 3.916 235.175

8 6.723 4.903 6.108 3.823

9 2.686 1.934 2.459 1.513

Critical Load Case for Sliding along X-Direction : 9

Governing Disturbing Force : -1.889 kip

Governing Restoring Force : 5.075 kip

Minimum Sliding Ratio for the Critical Load Case : 2.686

Critical Load Case for Overturning about X-Direction :

9

Page 56 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 57: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = 40.80 kip, Load Case # 5

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Governing Overturning Moment : 115.785 kip-in

Governing Resisting Moment : 284.694 kip-in

Minimum Overturning Ratio for the Critical Load Case :

2.459

Critical Load Case for Sliding along Z-Direction : 9

Governing Disturbing Force : 2.624 kip

Governing Restoring Force : 5.075 kip

Minimum Sliding Ratio for the Critical Load Case : 1.934

Critical Load Case for Overturning about Z-Direction :

9

Governing Overturning Moment : 188.154 kip-in

Governing Resisting Moment : 284.694 kip-in

Minimum Overturning Ratio for the Critical Load Case :

1.513

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 99.65 kip

Page 57 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 58: C Staad.foundation 4 CalcXsl Footing

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Distance along Z to design for shear, Dz = 48.70 in

From above calculations, 0.75 * Vc = 74.73 kip

Critical load case for Vux is # 5 7.01 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 99.65 kip

Distance along X to design for shear, Dx = 7.40 in

From above calculations, 0.75 * Vc = 74.73 kip

Critical load case for Vuz is # 5 7.03 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 22.15 in

Ultimate moment, 232.48 kip-in

Nominal moment capacity, Mn = 258.32 kip-in

Page 58 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 59: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Required = 0.00180

Since OK

Area of Steel Required, As = 1.49 sq.in

Available development length for bars, DL = 20.18 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 6

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.64 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00306

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

10.28 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 33.96 in

Page 59 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 60: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Program has detected one or more load cases to be in pure uplift, so footing needs to be designed for these cases with Top reinforcement.

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design for top reinforcement about Z axis

First load case to be in pure uplift # 9

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Ultimate moment, 231.91 kip-in

Nominal moment capacity, Mn = 257.68 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.41 sq.in

Available development length for bars, DL = 20.18 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 7

Total reinforcement area, As_total = Nbar * (Area of one bar) = 3.08 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00396

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

8.57 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

Page 60 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 61: C Staad.foundation 4 CalcXsl Footing

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Design for top reinforcement about X axis

First load case to be in pure uplift # 9

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about A axis is performed at the face of the column at a distance, Dx = 22.15 in

Ultimate moment, 57.46 kip-in

Nominal moment capacity, Mn = 63.85 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.41 sq.in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about A axis is performed at the face of the column at a distance, Dx = 22.15 in

Ultimate moment, 57.46 kip-in

Nominal moment capacity, Mn = 63.85 kip-in

Required = 0.00180

Page 61 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 62: C Staad.foundation 4 CalcXsl Footing

Find suitable bar arrangement between minimum and maximum rebar sizes

Since OK

Area of Steel Required, As = 1.49 sq.in

Isolated Footing 11

Input Values

Concrete and Rebar Properties

Concrete Covers

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Page 62 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 63: C Staad.foundation 4 CalcXsl Footing

Footing Design Calculations

Footing Size

Final dimensions for design.

Calculated pressures at 4 corners.

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Min. area required from bearing pressure, Amin = P / qmax = 0.002 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 41.34 in Governing Load Case : # 5

Width (W2) = 41.34 in Governing Load Case : # 5

Area (A2) = 1708.88 in2

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

8 0.07 0.02 0.04 0.08 -0.00

5 0.06 0.05 0.06 0.06 -0.00

5 0.06 0.05 0.06 0.06 -0.00

8 0.07 0.02 0.04 0.08 -0.00

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

8 0.07 0.02 0.04 0.08

5 0.06 0.05 0.06 0.06

5 0.06 0.05 0.06 0.06

8 0.07 0.02 0.04 0.08

Page 63 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 64: C Staad.foundation 4 CalcXsl Footing

Check for stability against overturning and sliding:-

Critical load case and the governing factor of safety for overturning and sliding

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 82.449 114.165 91.639 88.424

6 11.939 6.706 6.863 6.729

7 7.260 4.108 4.230 4.072

8 13.689 23.340 23.757 6.730

9 9.497 16.726 17.311 4.649

Critical Load Case for Sliding along X-Direction : 7

Governing Disturbing Force : -2.979 kip

Governing Restoring Force : 21.630 kip

Minimum Sliding Ratio for the Critical Load Case : 7.260

Critical Load Case for Overturning about X-Direction :

7

Governing Overturning Moment : 211.398 kip-in

Governing Resisting Moment : 894.161 kip-in

Minimum Overturning Ratio for the Critical Load Case :

4.230

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : 1.884 kip

Governing Restoring Force : 21.630 kip

Minimum Sliding Ratio for the Critical Load Case : 4.108

Critical Load Case for Overturning about Z-Direction :

7

Governing Overturning Moment : 219.563 kip-in

Governing Resisting Moment : 894.161 kip-in

Minimum Overturning Ratio for the Critical Load Case :

4.072

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

Page 64 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 65: C Staad.foundation 4 CalcXsl Footing

Punchng Shear Force, Pu = 55.04 kip, Load Case # 5

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along Z to design for shear, Dz = 41.32 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vux is # 5 0.04 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along X to design for shear, Dx = 0.02 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vuz is # 5 0.04 kip

0.75 * Vc > Vuz hence, OK

Page 65 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 66: C Staad.foundation 4 CalcXsl Footing

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 14.76 in

Ultimate moment, 253.94 kip-in

Nominal moment capacity, Mn = 282.16 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.10 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00346

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Page 66 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 67: C Staad.foundation 4 CalcXsl Footing

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 26.57 in

Ultimate moment, 253.72 kip-in

Nominal moment capacity, Mn = 281.91 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.04 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00384

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Page 67 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 68: C Staad.foundation 4 CalcXsl Footing

Isolated Footing 12

Input Values

Concrete and Rebar Properties

Concrete Covers

Soil Properties

Geometry

Initial Footing Dimensions

Pedestal

Footing Design Calculations

Footing Size

Unit Weight of Concrete : 24.000 kN/m3

Strength of Concrete : 25.000 N/mm2

Yield Strength of Steel : 415.000 N/mm2

Minimum Bar Size : # 6

Maximum Bar Size : # 18

Minimum Bar Spacing : 50.00 mm

Maximum Bar Spacing : 250.00 mm

Pedestal Clear Cover (P, CL) : 0.00 (null)

Footing Clear Cover (F, CL) : 50.00 mm

Unit Weight : 20.00 kN/m3

Soil Bearing Capacity : 300.00 kN/mm2

Soil Surcharge : 0.00 kN/mm2

Depth of Soil above Footing : 900.00 mm

Thickness (Ft) : 450.00 mm

Length - X (Fl) : 300.00 mm

Width - Z (Fw) : 300.00 mm

Eccentricity along X (Oxd) : 0.00 in

Eccentricity along Z (Ozd) : 0.00 in

Include Pedestal? No

Initial Length (Lo) = 11.81 in

Initial Width (Wo) = 11.81 in

Page 68 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 69: C Staad.foundation 4 CalcXsl Footing

Final dimensions for design.

Calculated pressures at 4 corners.

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative

pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary of adjusted pressures at 4 corners.

Adjust footing size if necessary.

Check for stability against overturning and sliding:-

Min. area required from bearing pressure, Amin = P / qmax = 0.003 in2

Area from initial length and width, Ao = Lo * Wo = 139.50 in2

Length (L2) = 41.34 in Governing Load Case : # 5

Width (W2) = 41.34 in Governing Load Case : # 5

Area (A2) = 1708.88 in2

Load CasePressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

Area of footing in uplift (Au)

(in2)

8 0.09 0.04 0.04 0.09 -0.00

5 0.08 0.07 0.07 0.08 -0.00

5 0.08 0.07 0.07 0.08 -0.00

8 0.09 0.04 0.04 0.09 -0.00

Load Case

Pressure at corner 1 (q1)

(kip/in^2)

Pressure at corner 2 (q2)

(kip/in^2)

Pressure at corner 3 (q3)

(kip/in^2)

Pressure at corner 4 (q4)

(kip/in^2)

8 0.09 0.04 0.04 0.09

5 0.08 0.07 0.07 0.08

5 0.08 0.07 0.07 0.08

8 0.09 0.04 0.04 0.09

Factor of safety against slidingFactor of safety against

overturning

Load Case No.

Along X-Direction

Along Z-Direction

About X-Direction

About Z-Direction

5 75.694 303.407 1516.189 64.090

6 26.525 46.972 70.559 11.386

Page 69 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 70: C Staad.foundation 4 CalcXsl Footing

Critical load case and the governing factor of safety for overturning and sliding

Critical load case and the governing factor of safety for overturning and sliding

Check Trial Depth against Punching Shear strength, Vc

Effective depth, deff, increased until 0.75*Vc Punching Shear Force

Punchng Shear Force, Pu = 70.54 kip, Load Case # 5

7 14.317 25.328 43.887 6.397

8 15.163 89.551 2154.369 7.952

9 9.864 53.243 5638.043 5.245

Critical Load Case for Sliding along X-Direction : 9

Governing Disturbing Force : -3.927 kip

Governing Restoring Force : 38.736 kip

Minimum Sliding Ratio for the Critical Load Case : 9.864

Critical Load Case for Overturning about X-Direction :

7

Governing Overturning Moment : -24.942 kip-in

Governing Resisting Moment : 1094.655 kip-in

Minimum Overturning Ratio for the Critical Load Case :

43.887

Critical Load Case for Sliding along Z-Direction : 7

Governing Disturbing Force : 0.728 kip

Governing Restoring Force : 26.480 kip

Minimum Sliding Ratio for the Critical Load Case : 25.328

Critical Load Case for Overturning about Z-Direction :

9

Governing Overturning Moment : 305.295 kip-in

Governing Resisting Moment : 1601.300 kip-in

Minimum Overturning Ratio for the Critical Load Case :

5.245

Calculated Effective Depth, deff = D - Ccover - 1.0 = 14.75 in

For rectangular column, = Bcol / Dcol = 1.00

From ACI Cl.11.12.2.1, for column = 106.24 in

Equation 11-33, Vc1 = 566.07 kip

Equation 11-34, Vc2 = 712.58 kip

Page 70 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 71: C Staad.foundation 4 CalcXsl Footing

Check Trial Depth against One-Way Shear strength, Vc

Shear along the Z-Z axis.

Check that 0.75 * Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the X axis.

Shear along the X-X axis.

Check that 0.75 * Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the

column caused by bending about the Z axis.

Design for Flexure about Z axis

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

Equation 11-35, Vc3 = 377.38 kip

Punching shear strength, Vc = 0.75 * minimum of (Vc1, Vc2, Vc3) = 283.03 kip

0.75 * Vc > Vu hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along Z to design for shear, Dz = 41.32 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vux is # 5 0.05 kip

0.75 * Vc > Vux hence, OK

From ACI Cl.11.3.1.1, Vc = 73.42 kip

Distance along X to design for shear, Dx = 0.02 in

From above calculations, 0.75 * Vc = 55.07 kip

Critical load case for Vuz is # 5 0.05 kip

0.75 * Vc > Vuz hence, OK

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl. 7.12.2, = 0.00180

Page 71 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 72: C Staad.foundation 4 CalcXsl Footing

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 5

The strength values of steel and concrete used in the formulae are in ksi

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about Z axis is performed at the face of the column at a distance, Dx = 14.76 in

Ultimate moment, 328.63 kip-in

Nominal moment capacity, Mn = 365.15 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.10 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 15.37 in

Reinforcement ratio, = 0.00346

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Factor from ACI Cl.10.2.7.3 for Fc' 4 ksi, 0.85

From ACI Cl. 10.3.2, = 0.02573

Page 72 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml

Page 73: C Staad.foundation 4 CalcXsl Footing

Calculate reinforcement ratio for critical load case

Find suitable bar arrangement between minimum and maximum rebar sizes

Because the number of bars is rounded up, make sure new reinforcement ratio < max

Check to see if width is sufficient to accomodate bars

From ACI Cl. 10.3.3, = 0.01929

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 19.53

Design for flexure about X axis is performed at the face of the column at a distance, Dz = 26.57 in

Ultimate moment, 317.21 kip-in

Nominal moment capacity, Mn = 352.45 kip-in

Required = 0.00180

Since OK

Area of Steel Required, As = 1.04 sq.in

Available development length for bars, DL = 12.80 in

Try bar size # 6 Area of one bar = 0.44 sq.in

Number of bars required, Nbar = 5

Total reinforcement area, As_total = Nbar * (Area of one bar) = 2.20 sq.in

deff = D - Ccover - 0.5 * (dia. of one bar) = 13.87 in

Reinforcement ratio, = 0.00384

From ACI Cl.7.6.1, minimum req'd clear distance between bars, Cd =

max (Diameter of one bar, 1.0, Min. User Spacing) =

9.16 in

Print Calculation Sheet

Page 73 of 73Isolated Footing Design

3/17/2013file://C:\Staad.foundation 4\CalcXsl\footing.xml