C O N T E N T SATR 0, 1 & 2 Series
True RMSAC Current Transducers 2–3
AT 0, 1 & 2 SeriesAC Current Transducers 4–5
ATR 3 & 4 SeriesHigh Current Transducers 6–7
DT 1, 2, 3 & 4 SeriesDC Current Transducers 8–9
AS1 Series Current Operated Switches 10–11ASM Series Self Calibrating
Current Switches 12–13AS3 Series Current Operated Switches 14–15AS3M Series Multi-pole
Current Operated Switches 16AG 1, 2 & 3 Series
Ground Fault Sensors 17–19DS3 Series DC Current Switches 20–21Accessories ■ PBR Series
PowerBASE™ Relays 22■ Power Supply 23■ DIN Universal Rail Clips 23■ Instrument Tags 23
know your power . . .because with knowledge comes control.
For expert technical help, contact your localAuthorized Representative or Authorized Distributor
know your power . . .because with knowledge comes control.
PAGE
849 Independence Avenue ■ Mountain View, CA 94043 ■ Toll Free: 800/959-4014Phone: 650/940-7878 ■ Fax: 650/940-7880 ■ e-mail: [email protected] ■ www.NKtechnologies.com
IndustrialCurrentSensors
Do you have other needs?
Contact us for:■ Product Guide
■ Application Guide■ Power Transducers, CTs and PTs■ Current Transducers and Transmitters
■ Current Switches■ Current Fault Sensors
Do you have other needs?
IndustrialCurrentSensors
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
ApplicationsVFD Controlled Loads
VFD output indicates how the motor and attached load are operating.
SCR Controlled LoadsAccurate measurement of phase angle fired or burst fired (time proportioned)SCRs. Current measurement gives faster response than temperaturemeasurement.
Switching Power Supplies and Electronic BallastsTrue RMS sensing is the most accurate way to measure power supply or ballastinput power.
True RMS AC Current Transducers
Features■ True RMS Output
True RMS technology is accurate ondistorted waveforms like VFD or SCRoutputs.
■ Jumper Selectable Ranges— Reduces inventory.— Eliminates zero and span pots.
■ Isolation— Output is magnetically isolated
from the input for safety.— Eliminates insertion loss
(voltage drop).
■ UL, CUL and CE ApprovalAccepted worldwide.
137.2A
Controller
Two Wire Installation is Fast and Easy
FieldSelectableRanges
True RMS Outputeven on VFDs or SCRs
LINE VFD
54.7Hz
M
True RMS AC Current Transducers
ATR SeriesSelecting the right transducer:
VFD and SCR output waveforms arerough approximations of a sine wave.There are numerous spikes and dips ineach cycle. ATR transducers use amathematical algorithm called “TrueRMS,” which integrates the actualwaveform over time. The output is theamperage component of the true power(heating value) of the AC currentwaveform. True RMS is the only way toaccurately measure distorted ACwaveforms. Select ATR transducers fornonlinear loads or in “noisy” powerenvironments.
The current waveform of a typical linearload is a pure sine wave. AT transducersmeasure the peaks of these sine waves,then calculate the average amperage.This works well on constant speedlinear loads in a “clean” powerenvironment. Select AT transducers forstrictly linear loads on “clean” power.
‘ATR’ transducers from NK Technologies combine a currenttransformer and a True RMS signal conditioner into a single package.The ATR Series provides True RMS output on distorted waveformsfound on VFD or SCR outputs and on linear loads in “noisy” powerenvironments. Available in a solid or split core case.
ATR SeriesATR Series
Power SupplyDIN Rail AdapterInstrument Tags
AccessoriesPAGE 23
Accessories
DIN-2 adapters allow NK Technologiesswitches, transducers and ground faultsensors to be mounted on DIN rail.
SpecificationsCompatibility ■ “Top Hat” Type: 35mm x 15mm,
35mm x 7.5mm■ “G” Type: 32mm x 15mm
Material UL 94V-2 Rated thermoplasticTemp Range –40 to 212°F (–40 to 100°C)
Instrument Tags allow users to individually identify eachNK Technologies sensor in their system. IT Tags arepermanent and non conductive. Traditional stampedstainless steel tags present a safety hazard and are notrecommended for electrical sensors. Please provide a list oftag numbers with your Purchase Order.
SpecificationsDimensions 0.5" x 1.125"Characters 2 lines of 18 characters (8 point).
Spaces and dashes count as characters.
PAGE 2
True RMS AC Current Transducers
Power SupplyPower Supply
SpecificationsInput 85–264VAC, 47-400HzDC Output 24VDC, 25W (1.05A)DC Regulation +/–0.2% (0.048VDC)DC Ripple 100mV (Peak-Peak)EMF Meets FCC Part 15J, Class BDimensions 5.1" x 3.85" x 1.5", 1.5 lb.
(13 x 9.8 x 3.8 cm, 700 gm)
Environmental 14 to 140°F (–10 to +60°C), 20–90% RHSafety UL Recognized, CE
PS series switchingpower suppliesprovide highlyregulated 24VDC forNK Technologiestransmitters and switches.
DIN Rail AdapterDIN Rail AdapterSensor and DINrail not includedin DIN-2 kit.
Instrument TagsInstrument Tags
ATR Series AccessoriesAccessories
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
2(+)1(–)Output
Range Jumper
(+)(–)24 VDC Power
(+)
(–)
Load(Controller, Meter, etc.)
2(+)1(–)Output
Range Jumper
4–20mA Option
0–5/10 VDC Option 1mΩ Recommended100kΩ Acceptable
PBR Series PowerBASE™ RelaysPBR Series PowerBASE™ Relays
know your power . . .because with knowledge comes control.
SpecificationsOutput Signal 4–20mA, Loop-powered, True RMSOutput Limit 23mAAccuracy 0.8% FSResponse Time 600mS (to 90% step change)Frequency Range 10–400HzPower Supply 24VDC Nominal, 40VDC MaximumIsolation Voltage UL listed to 1,270VAC, tested to 5KVInput Ranges Field selectable from 0–200A (see Ordering
Information). Consult factory for custom ranges.Sensing Aperture ■ –FT Models: 0.75" (19mm) dia.
■ –SP Models: 0.85" (21.5mm) sq.Case UL 94V-0 Flammability ratedEnvironmental –4 to 122°F (–20 to 50°C),
0–95% RH, non-condensingListings UL 508 Industrial Control Equipment
(USA & Canada), CE
0 500250 1000750Total Loop Impedance (Ohms)
32
27
22
17
12Loop
Pow
er (
VDC)
Operating Range
Notes:■ Deadfront captive screw
terminals (–SP case).■ 12–22 AWG solid or stranded.■ Observe polarity.
Input Ranges MAXIMUMModel Range Continuous 6 Sec. 1 Sec. ATR0 2A 80A 125A 250A
5A 100A 125A 250A ATR1 10A 80A 125A 250A
20A 110A 150A 300A50A 175A 215A 400A
ATR2 100A 200A 300A 600A150A 300A 450A 800A200A 400A 500A 1,000A
Power Supply (4–20mA output only)VL = 12VDC + (RL × 0.020A)
where VL = Minimum Loop SupplyRL = Total Loop Resistance (Ohms)
ATR SeriesPAGE 3
ATR Series
1.93"49mm
2.18"55.4mm
0.6"15mm
0.931"23.7mm
2.433"61.8mm
3.53"89.7mm
1.506"38.3mm
3.08"78mm
1.5"39mm
0.125"3.2mm
0.75"19mm
dia.
0.967"24.56mm
0.17"4.5mm int. dia.Typical of 2
LEDPOT
2.25"57.2mm
2.4"61mm
0.854"21.7mm
0.857"21.7mm
0.72"18.3mm
0.52"13mm
0.19"4.5mm dia.Typical of 2
0.36"9.1mm
0.52"13mm
2.4"61mm
3.53"89.7mm
3.044"77.3mm
1.18"30mm
0.125"3.2mm
True RMS AC Current Transducers
Example: ATR1-420-24L-SPTrue RMS AC current transducer, 10/20/50A ranges, 4–20mA output,24VDC loop-powered in a split core case.
Full ScaleRanges0 2 & 5A1 10, 20, 50A2 100, 150, 200A
Output Signal420 4–20mA
CaseFT Fixed Core, Top Term.SP Split Core
ATR
Ordering Information
Power Supply24L 24VDC
Loop-powered
PBR “PowerBASE™” Series are industrial-graderelays in a specially designed package. PBR relaysquick connect to NK Technologies top terminal ASand AT series current switches and transducers.This compact combination provides for addedfunction and flexibility.
PowerBASE™ Command Relays
AccessoriesPAGE 22
ApplicationsMotor Control
— Switches up to NEMA Size 5 starter (200HP motor).— Directly controls fractional HP loads.
Heaters and Lamp ControlEliminates contactors for loads to 10A.
Contact Rating10C 10A Form C
Coil Voltage (see Specifications)12U 12VAC/DC, Low Current24U 24VAC/DC, Low Current
Example: PBR-10C-24LPowerBASE™ Relay with 10A contacts and universal 24-volt coil.
Ordering InformationPBR
LINE
ControllerDO
Digital Out
FAN ON
Starter
DIDigital
In
AS Current Switch orAT Current Transducer
PowerBase™Relay10 amp Form C (SPDT)
Eliminates Relay PanelSaves Labor and Materials
M
Accessories
1 0 C
Connections
4 2 0 2 4 L
FT Case
SP Case
SpecificationsContacts ■ 10A Resistive, 7.2A Inductive @ 240VAC
■ 1/3HP @ 240VAC■ 10A @ 30VDC
Coils ■ 12L: 12VAC/DC +/–30%, 18.5mA■ 24L: 24VAC/DC+/–30%, 10mA
Dimensions 2.65"W x 1.5"D x 0.9"H, 4.5" BaseCase UL 94 Flammability ratedCompatibility ■ Solid Core Sensors: All “FT” case models
■ Split Core Sensors: All “SP” case models
Environmental –4 to 122°F (20 to 60°C), 0-95% RH, non-condensingListings UL 508 Industrial Control Equipment
(USA & Canada), CE
Features■ PowerBASE™ Relay and Current Sensor combo
— Acts as an ‘Interposing Relay’.—␣I solates controller from line voltage.
■ Cuts Installation Costs— Installs as one item.—␣Cuts electri cian’s labor.— Eliminates need for relay panel.
■ Assembly Options— Factory assembled for convenience.— Field assembled for flexibility.
■ UL, CUL and CE ApprovalAccepted worldwide.
AccessoriesAccessories
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
Connections
Notes:■ Pressure plate screw terminals.■ 12–22 AWG solid or stranded.■ Field adjustable setpoint.
Example: DS1-SDT-24UDS current switch, low range with SPDT relay contacts and 24VAC/DCpower supply.
Ordering Information543
Setpoint
21Power
Power Supply24 VAC/DC
Isolated Relay Output(Shown De-Energized)
Isolated Solid State Output(Shown De-Energized)
43
SetpointG R R
SpecificationsOutput Isolated dry contactOutput Rating ■ Solid State: 0.2A @ 240VAC/DC
(N.O. Only)■ Relay: 5.0A @ 240VAC, 5.0A @ 30VDC (SPDT)
Off State Leakage NoneResponse Time ■ 100mS (10% above Setpoint)
■ 20mS (100% above Setpoint)Setpoint Range 4–20, 10–50 and 15–100A (DC)
Jumper select (derate by √2 for AC)Hysteresis 5% of SetpointOverload ■ 1,000% of range for 5 seconds
■ 200% of range indefinitelyIsolation Voltage 3kVFrequency Range DC to 400HzSensing Aperture 0.75" (19mm) dia.Power Supply 20–28VDC or VACPower Consumption 10VACase UL 94V-0 Flammability ratedEnvironmental ■ –4 to 122°F (–20 to 50°C),
0–95% RH, non-condensing■ –40 to 140°F (–40 to 60°C) (Solid State Output Only)
Setpoint Range3 4–20, 10–50 and
15–100A, Jumper SelectC Custom (consult factory)
Ouput TypeSDT SPDT Relay (Form C)NOU Solid State N.O. AC/DC
DS
Power Supply24U +24VAC/DC
DC Current Switches
DS3 SeriesPAGE 21
DS3 Series
2.5"63.5mm
0.75"19mm
1.5"38.1mm
1.01"25.5mm
1.510"38.4mm
1.055"27mm
LED
LED
Range Jumper
POT
3.375"85.7mm
0.75"19mmdia.
0.5"12.7mm
3.875"98.4mm
0.177"4.5mm int. dia.Typical of 2
0.125"3.2mm
TIME
AMPS
100%
0%
ContactDe-energized
ContactEnergized
FIELD ADJUSTABLE SETPOINT
Adaptive Hysteresis:5% of Setpoint
Output Operation
‘AT’ Current Transducers from NK Technologies combinea current transformer and signal conditioner into a single
package. The AT Series has jumper selected currentinput ranges and industry standard
4–20mA, 0–5VDC or 0-10VDCoutputs. The AT Series isdesigned for application on‘linear’ or sinusoidal AC loads.Available in a split core case ortwo types of solid core cases.
ApplicationsAutomation Systems
Analog current reading for remote monitoring and software alarms.
Data LoggersSelf-powered transducer does not drain data logger batteries.
Panel MetersSimple connection displays power consumption.
AT Series
LINE
M
137.2A
ControllerFieldSelectableRanges
Two Wire Installation is Fast and Easy
Safer than Shunts
AC Current Transducers0–5/10VDC or 4–20mA Output
AT Series
AT Current Transducers0–5/10VDC or 4–20mA Output
AT SeriesPAGE 4AT Series
AT Current Transducers0–5/10VDC or 4–20mA Output Features
■ AccurateFactory matched and calibratedsingle piece transducer is moreaccurate than traditional two-piecefield installed solutions.
■ Average Responding“Average Responding” algorithmgives a RMS output on pure sinewaves. Perfect for constant speed(linear) loads.
■ Jumper Selectable Ranges— Reduces inventory.— Eliminates zero and span pots.
■ Isolation— Output is magnetically isolated
from the input for safety.— Eliminates insertion loss
(voltage drop).
■ UL, CUL and CE ApprovalAccepted worldwide.
Input Ranges MAXIMUMModel Range Continuous 6 Sec. 1 Sec. AT0 2A 80A 60A 100A
5A 100A 124A 250A AT1 10A 80A 125A 250A
20A 110A 150A 300A50A 175A 215A 400A
AT2 100A 200A 300A 600A150A 300A 450A 800A200A 400A 500A 1,000A
2 4 U
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
2(+)1(–)Output
Range Jumper
(+)(–)24 VDC Power
(+)
(–)
Load(Controller, Meter, etc.)
2(+)1(–)Output
Range Jumper
4–20mA Option
0–5/10 VDC Option 1mΩ Recommended100kΩ Acceptable
Connections
Notes: ■ Captive screw terminals.■ 12–22 AWG solid or stranded.■ Observe polarity.
LEDPOT
0.47"12mm
0.17"4.5mm int. dia.Typical of 2
1.650"27mm
0.125"3.2mm
0.55"14mm dia.
3.3"83.8mm
2.75"69.9mm
0.92"23.4mm
1.2"31mm
Jumper
1.75"45mm
0.95"24.1mm
2.18"55.4mm
1.93"49mm
2.18"55.4mm
0.6"15mm
0.931"23.7mm
2.433"61.8mm
3.53"89.7mm
1.506"38.3mm
3.08"78mm
1.5"39mm
0.125"3.2mm
0.75"19mm
dia.
0.967"24.56mm
0.17"4.5mm int. dia.Typical of 2
LEDPOT
AT SeriesPAGE 5
AT Series
AC Current Transducers0–5/10VDC or 4–20mA Output
ApplicationsElectric Heating Elements
Instant indication of heater status.
Power SuppliesSignals over-current before equipment fails.
Machine OperationInstant status of motors, lamps and other loads.
Telecom SitesMonitors battery output.
‘DS3’ Current Switches from NK Technologies combine aHall effect sensor, signal conditioner and a limit alarm into asingle package. The DS3 Series has three jumper selectedcurrent input ranges and frequency response from DC to400Hz. Available in a top terminal solid core case witheither a relay output or a universal solid state output.
Features■ Compact, One-piece Design
Fits in crowded motor starters, power supplies and controlpanels.
■ Input IsolationMuch safer than shunt/relay combinations.
■ Output InstallationIsolated output greatly simplifies wiring.
■ ToughDesigned to handle harsh industrial environments.
■ Adaptive Hysteresis— Hysteresis is 5% of setpoint.— Allows closer control than fixed hysteresis.
■ ReliableSolid state design.
■ Built-in Mounting BracketSolid, secure mounting that inspectors want to see.
DC Current Switches
DS3 Series
DC Current Switches
Load ON
Controller
Isolated output simplifies wiring.
24VAC or VDC
Isolated input is safe.
FieldAdjustableSetpoint
To1,200VDC
DC Current Switches
DS3 SeriesPAGE 20
DS3 Series
DS3 Series
Specifications–005 Models –010 Models –420 Models
Output Signal 0–5VDC 0–10VDC 4–20mAOutput Limit 10VDC 15VDC 40mAAccuracy 1.0% FS 1.0% FS 0.5% FSResponse Time 100mS 100mS 300mS(10–90% step change)Frequency Range 50–60Hz 50–60Hz 20–100Hz*Other Frequencies Special calibration available for any frequency from 10–400Hz*Power Supply Self-powered Self-powered 12–40VDC,
Loop-poweredLoading 1mΩ minimum for rated accuracy See “Power Supply”
100KΩ add 1.3% error belowIsolation Voltage UL listed to 1,270VAC, tested to 5KVInput Ranges Field Selectable Ranges from 0–200A (see Ordering
Information). Custom ranges available, consult factory.Sensing Aperture ■ –FF Case : 0.55" (14mm) dia.
■ –FT Case : 0.75" (19mm) dia.■ –SP Case: 0.85" (21.5mm) sq.
Case UL 94V-0 flammability ratedEnvironmental –4 to 122°F (–20 to 50°C), 0–95% RH, non-condensingListings UL 508 Industrial Control Equipment (USA & Canada), CE*For sinusoidal waveforms only. Select ATR Transducersfor distorted waveforms.
2.25"57.2mm
2.4"61mm
0.854"21.7mm
0.857"21.7mm
0.52"13mm
0.22"5.7mm
0.52"13mm
3.53"89.7mm
0.188"4.5mm int. dia.Typical of 2
1.190"30.2mm
0.125"3.2mm
2.4"61mm
3.044"77.3mm
Ordering InformationExample: AT1-005-000-SPAC current transducer, 10/20/50A range, self-powered with a 0–5VDCoutput in a split core case.
Full ScaleRanges0 2 & 5A1 10, 20, 50A2 100, 150, 200A
Output Signal420 4–20mA005 0-5VDC010 0-10VDC
Power Supply24L 24VDC Loop-powered
(4–20mA output ONLY)000 Self-powered (0–5/
0–10VDC output ONLY)
AT
CaseFF Fixed Core,
Front Term.FT Fixed Core,
Top Term.SP Split Core
FT Case
SP Case
FF Case
Power Supply (4–20mA output only)
0 500250 1000750Total Loop Impedance (Ohms)
25
20
15
10
5Loop
Pow
er (
VDC)
Operating Range
VL = 12VDC + (RL × 0.020A)where VL = Minimum Loop Supply
RL = Total Loop Resistance (Ohms)
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
Normally Energized Models (–FS Option)Protection from faultsand loss ofcontrol power. No Power No Fault Fault
N.C. Normally Closed Closed OPEN Closed
N.O. Normally Open Open CLOSED Open
Normally Deenergized Models (–NF Option)Protection from faultsonly when control poweris applied. No Power No Fault Fault
N.C. Normally Closed Closed CLOSED Open
N.O. Normally Open Open OPEN Closed
Latching (–LA Option)Latching models initially power up in the Reset position.If there is a fault or the test button is pressed, theoutput switches and is latched. The output will remainlatched after the fault is cleared, even if control power isremoved. To reset the output, apply a momentary contactacross the “Reset” terminals (6–7).
Output TableControl Power Applied
Control Power Applied
SpecificationsSetpoint Range■ “Single-Set” Models Factory adjusted and sealed
(field adjustment possible)■ AG1: 5–100mA, specify when ordering■ AG2: 80–950mA, specify when ordering
■ “Tri-Set” Models 5, 10 & 30mA jumper selectOutput Isolated dry contact (solid state or relay,
see Ordering Information)Output Rating ■ Solid State AC Switch: 1A @ 240VAC
■ Solid State DC Switch: 0.15A 30VDC■ Relay: 0.5A @ 125VAC, 2A @VDC
Off State Leakage NoneResponse Time ■ 200mS @ 5% above setpoint
■ 60mS @ 50% above setpoint■ 15mS @ 500% above setpoint
Isolation Voltage Up to 1,250VAC (monitored circuit)Frequency Range 50–400Hz (monitored circuit)Sensing Aperture 0.75" (19mm) dia., up to 4" (100mm) dia.
available, consult factory.Power Supply ■ 120, 200, 208, 220, 240VAC, 50-400Hz,
operates from 55–110% of nominal voltage■ 24VAC & 24VDC, operates +/–10%■ Green LED = power (all models)
Case UL 94V-O Flammability ratedEnvironmental 5 to 158°F (–15 to 70°C),
0-95% RH, non-condensingSafety UL 1053, Class 1 Recognized, CE**Most option combinations are UL recognized.
Ground Fault Sensors
AG SeriesPAGE 19
AG Series
‘AT/ATR 3 & 4’ transducers from NK Technologiescombine a high capacity current transformer and asignal conditioner into a single package. The ATversion is Average Responding for use on linear(sinusoidal) loads. The ATR version is True RMS for useon distorted waveforms found in VFD or SCR outputs.Available in a solid or split core case.
ApplicationsLarge Pumps
Detect dry run electronically.
GenerationMeasure the output of generators.
Electric Heating Elements— Monitors heater load.— Faster response than
temperature sensors.
High Current Transducers
High Current Transducers
Features■ Large Aperture
Accommodates large conductors orwire bundles.
■ Select the Right OutputTrue RMS technology is accurate ondistorted waveforms like VFD or SCRoutputs.Average Responding—for linear,sinusoidal waveforms
■ Three Jumper Selectable Ranges— Reduces inventory.— Eliminates zero and span pots.
■ IsolationMagnetic isolation protects installersand systems.
■ Easy InstallationSingle piece with integral mountingbrackets makes for a simple, solidinstallation.
■ UL, CUL and CE ApprovalAccepted worldwide.
ATR 3 & 4 SeriesPAGE 6
Selecting the right transducer:The current waveform of a typical linearload is a pure sine wave. AT transducersmeasure the peaks of these sine waves,then calculate the average amperage.This works well on constant speedlinear loads in a “clean” powerenvironment. Select AT transducers forstrictly linear loads on “clean” power.
VFD and SCR output waveforms arerough approximations of a sine wave.There are numerous spikes and dips ineach cycle. ATR Transducers use amathematical algorithm called “TrueRMS,” which integrates the actualwaveform over time. The output is theamperage component of the true power(heating value) of the AC currentwaveform. True RMS is the only way toaccurately measure distorted ACwaveforms. Select ATR transducers fornonlinear loads on “noisy” power.
High Current Transducers
ATR 3 & 4 Series
1837.2A
Controller
Single Piece DesignCuts Panel Labor
FieldSelectableRangesTrue RMS Output
works on VFDs
LINE
M
AT/ATR 3 & 4 SeriesAT/ATR 3 & 4 Series
Shown withsolid core case.
Example: AG1-NOAC-120-005-FSGround fault sensor with normally open solid state output, 120VAC power supply, 5mA setpoint, fail safe version.
Power Supply24U 24VAC/DC120 120VAC200 200VAC208 208VAC240 240VAC
Output TypeNCAC Normally Closed 1A @ 240VACNOAC Normally Open 1 A @ 240VACNCDC Normally Closed 0.15A @ 30VDCNODC Normally Open 0.15A @ 30VDCNCR1 Normally Closed Relay,
0.5A @ 125VAC, 2A @ 30VDCNOR1 Normally Open Relay,
0.5A @ 125VAC, 2A @ 30VDCCR1 Form C Relay (SPDT) 0.5A @ 125VAC, 2A @ 30VDC
(available only with LA Latching Option)
SetpointTR3 Tri-Set Models005 Factory Adjusted
Setpoint in mA950
AG
Ordering Information
Setpoint Range1 5–100mA, Adjustable2 80–950mA, Adjustable3 5, 10 & 30mA, Jumper Select
OptionsFS Normally EnergizedNF Normally DeenergizedLA Latching (available only
with CR1 Output Option)
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
2(+)1(–)OutputRange Switch
MidLow High
(+)(–)24 VDC Power
(+)
(–)
Load(Controller, Meter, etc.)
know your power . . .because with knowledge comes control.
SpecificationsOutput Signal 4–20mA, Loop-poweredOutput Limit 23mAAccuracy 1.0% FS accuracy, True RMSMeasurement True RMS or Average Responding
(see Ordering Information)Response Time 500mS (to 90% of step change)Frequency Range ■ ATR: 10–400Hz
■ AT: 50–60Hz, SinusoidalPower Supply 24VDC Nominal; 40VDC MaximumIsolation Voltage 600VACInput Ranges ■ AT/ATR3: 375, 500, 750A
■ AT/ATR4: 1000, 1333, 2000ASensing Aperture 3.0" (76mm) dia.Case UL 94 Flammability ratedEnvironmental –4 to 122°F (–20 to 50°C),
0–95% RH, non-condensingListings UL 508 Industrial Control Equipment
(USA & Canada), CE
Connections
Notes:■ Deadfront captive screw
terminals.■ 12–22 AWG solid or stranded.■ Observe polarity.
ATR 3 & 4 SeriesHigh Current Transducers
Example: ATR4-420-24L-FLTrue RMS AC current transducer, 24VDC powered with a 4–20mAoutput, 375, 500 and 750 amp range in a fixed core case.*
MeasurementR True RMS— Average
Responding(Blank)
Output Signal420 4–20mA
Case*FL Fixed Core
AT
Ordering Information
Power Supply24L 24VDC
Loop-powered
ATR 3 & 4 SeriesPAGE 7
2.5"63mm
2.75"70mm
0.75"19mm
1.5"38mm
3.4"86mm
1.0"25mm 3.85"
98mm
0.75"19mm
dia.
1.1"28mm
0.177"4.5mm int. dia.Typical of 2
TESTFaultFault
Setpoint
Setpoint Jumper Location for Tri-Set Models
0.125"3.2mm
2.5"63.5mm
0.11"2.8mm
0.75"19mm
1.5"38.1mm
1.510"38.4mm
3.375"85.7mm
3.875"98.4mm
0.75"19mmdia.
1.055"27mm
0.177"4.5mm int. dia.Typical of 2LED LED
POT
2.895"73.5mm
TEST
Setpoint Jumper Location for Tri-Set Models
0.125"3.2mm
AG Series continuedPAGE 18
AG Series continued
Ground Fault Sensors
ConnectionsOutputPower
Jumper Location for Tri-Set Models
TESTG R
Jumper Location for Tri-Set Models
TEST
G RPower Status
Setpoint
1 2 3 54
Power Output Reset
6 7 Typical of Latching Version
Typical of Auto-reset Version
Notes:■ Terminals are #6 screws.■ Connections are polarity sensitive.■ Adjustable Setpoint version has setpoint adjust
but no jumper.
4.215"107mm
0.75"19mm
3.375"85.7mm
3.375"85.7mm
1.463"37.2mm
0.825"20.95mm
3.0"76mmdia.
0 500250 1000750Total Loop Impedance (Ohms)
32
27
22
17
12Loop
Pow
er (
VDC)
Operating Range
Power SupplyVL = 12VDC + (RL × 0.020A)
where VL = Minimum Loop SupplyRL = Total Loop Resistance (Ohms)
FL Case
Full ScaleRanges3 375, 500,
750A4 1000, 1333,
2000A*Split core version available in the Spring of 2000.
F L2 4 L4 2 0
OutputPower
Jumper Location for Tri-Set Models
TESTG R
Jumper Location for Tri-Set Models
TEST
G RPower Status
Setpoint
1 2 3 54
Power Output Reset
6 7 Typical of Latching Version
Typical of Auto-reset Version
Notes:■ Dead front terminals.■ Connections are not polarity sensitive.
Latching
FS/NF Option
AG Series continued
AG Series continued
Latching versionshown.
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
DT Series
DC Current Transducers0–3/5/10VDC or 4–20mA Output
DT SeriesDT Series
ApplicationsBattery Banks
— Monitors load current.— Monitors charging current.— Verifies operation.
TransportationMeasures traction power orauxiliary loads.
Electric Heating ElementsFaster response thantemperature sensors.
137.2A
Controller
Industry Standard Outputs
FieldSelectableRanges
AC or DC Power
To1,200VDC
Split Core Cuts Labor
DC Current Transducers0–3/5/10VDC and 4–20mA Output
DT Series
PAGE 8
ApplicationsPersonnel Protection (typically 5mA)
Senses low fault currents and alarms to shut power before injury occurs.
Equipment Protection (typically 30mA)When personal protection is not an issue, select a higher setpoint to protectequipment or product
Regulatory ApprovalMeet requirements by industry groups and governments for Ground FaultProtection.
Operating Principal: Under normalconditions, the current in the hot legof a two-wire load is equal in strengthbut opposite in sign to the current inthe neutral leg. These two currentscreate magnetic fields that are alsoequal but opposite. When the wires arenext to each other, the fields cancel,producing a “Zero Sum Current”. If anycurrent leaks to ground from one wire(Ground Fault), the two currentsbecome imbalanced and the result is anet magnetic flux or field. AG Seriesground fault sensors monitor this fieldand alarm when leakage rises abovesetpoint. This concept applies togrounded 3-phase delta and wye systems.
Ground Fault Sensors
Ground Fault Sensors
Ground Fault Sensors
AG Series
Features■ Operation to Match Your
Application:Latching—For controllingcontactors.Auto-Reset—For controllingshunt trip breakers.
■ Setpoint Options to Match YourNeeds:Tri-Set—Field select 5, 10 or 30mA.Fast and convenient. (AG3 only)Single-Set—Factory adjustedsetpoint. Specify 5–100mA (AG1) or80–950mA (AG2) when ordering.
■ Compatible with StandardEquipmentWorks on 1φ or 3φ power. Controlsstandard shunt trip breakers orcontactors. Tie into EmergencyCircuits (EMO/EPO).
■ IsolatedMagnetically isolated from themonitored circuit and control power
■ UL and CE ApprovalAccepted worldwide.
Power
LINE
LOAD
Output
Power Interrupt
Easy to Apply on 1φ or 3φ Circuits to 1,250 VAC Protects your people,
products and processes.
AG SeriesPAGE 17
AG Series‘AG’ Series sensors fromNK Technologies protectpeople, products andprocesses from groundfaults by monitoring allcurrent-carrying wires ingrounded single or 3-phase systems.
AG Series
DC Current Transducers0–3/5/10VDC or 4–20mA Output
‘DT’ Current Transducers from NK Technologies combine aHall effect sensor and signal conditioner into a single package. TheDT Series has jumper selectable current input ranges and industrystandard 0–20mA, 4–20mA, 0–3VDC, 0–5VDC or 0–10VDC outputs.Available in a split core package.
Features■ Three Jumper Selectable Ranges
— Reduces inventory.— Eliminates zero and span pots.
■ Isolation— Output is magnetically isolated
from the input for safety.— Eliminates insertion loss
(voltage drop).
■ Internal Power Regulation— Works well, even with unregulated
power.— Cuts installation costs.
■ Easy InstallationSplit core design with built-inmounting brackets makes installationa snap.
Auto-reset versionshown.
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
Multi-pole Current Operated Switches
ApplicationsPump Control
Individually adjustable indication of overload (jam) and underload (suction loss).Dual Alarm
Easy setup for dual level alarms.
Features■ Multi-pole Output
Monitor two setpoints with onesensor.
■ Self-poweredCuts installation and operating costs.
■ Easily Adjustable SetpointSpeeds startup.
■ Solid or Split Core CaseChoose the right version for eachinstallation.
■ Built-in Mounting BracketProvides the solid installationinspectors want.
■ UL, CUL and CE ApprovalAccepted worldwide.
PAGE 16AS3M SeriesAS3M Series
AS3M-CCDC-FTLINE
1 C 2
Over/Under Current Alarm with Two Inputs
Over/Under Current Alarm with One Input (Jumper Provides Hard-Wired"OR" Function)
+ +
156.2A
Controller
LINE
1 C 2Multi-pole Current Switch
AC Power Leg to Motor
+ +
156.2A
Controller
MotorCurrent
HighSetpoint
Low Setpoint
AMPS
TIME
Starting Inrush Current Normal Operation
UnderCurrent Alarm
OverCurrentAlarm
Contact Truth
80% 120% Setpoint, % FLA
Over Amps
Normal AmpsWindow
Under Amps
Power OFF
#1(N.C.)
#2(N.O.)
CONTACT
DESCRIPTION
AS3M-CCDC-FT
Example: AS3M-CCDC-FFAdjustable multipole current switch, “Super”Form C output, fixed core with front terminals.
Output RatingAADC Dual Normally Open,
Individually Adjustable,0.15A @ 30VDC
CCDC “Super” Form C SPDT,Individually Adjustable,0.15A @ 30VDC
Case StyleFF Fixed Core,
Front Term.
AS3M
Ordering Information
AS3M Series
Multi-pole Current Operated Switches
AS3M Series‘AS3M’ Current Switches are a multi-pole version of the popularAS3 Series. The AS3M Series combines a current transformer, signalconditioner and two limit alarms into a single package. The AS3Series has three jumper-selected current input ranges, solid-stateDC output and a wide frequency range. Available in a front terminalsolid core case.
SpecificationsSee page 15, “AS3 Series” specificationsand dimensional drawings.
Multi-pole Current Operated Switches
Connections
Output Polarity
DT SeriesPAGE 9
DT Series
DC Current Transducers0–3/5/10VDC and 4–20mA Output
SpecificationsOutput Signal 0-20mA, 4-20mA, 0-3VDC, 0-5VDC or 0-10VDCOutput Limit ■ 0–20mA, 4–20mA: 44mA
■ 0–3VDC: 6.5VDC■ 0–5VDC: 13VDC■ 0–10VDC: 26VDC
Accuracy 1.0% FSRepeatability 1.0% FSResponse Time 100mS (to 90% of step change)Frequency Range DCPower Supply 20–50VDC, 22–38VAC. Power input and
output signal are not isolated.Power Consumption 2VALoading ■ 0–20mA, 4–20mA: 650Ω max.
■ 0–3/5/10VDC: 250kΩ for rated accuracy; 25kΩ, add 1% error.
Isolation Voltage 3kV (monitored line to output)Linearity 0.75% FSCurrent Ranges Field Selectable Ranges from 0–400A
(see Ordering Information)Sensing Aperture 0.85" (21.5mm) sq.Case UL 94V-0 Flammability ratedEnvironmental –4 to 122°F (–20 to 50°C),
0–95% RH, non-condensing
100
50
0
– Amps + Amps0
Output (%)
Unipolar (Magnitiude
Only)
4(+)3(–)2(+)1(–)Power Output
20–50 VDC or 22–38 VAC
Output loop is powered byDT Transducer. No loop power supply required.
Range Jumper
Notes:■ Deadfront captive screw
terminals.■ 12–22 AWG solid or stranded.■ Observe polarity.
F F Output Polarity*U Unipolar
Example: DT2-420-24U-USplit core DC/DC current switch, mid range, 24VAC/DC powered with a4–20mA output that is unipolar.
Ordering Information
Full Scale Range1 50, 75, 100A2 100, 150, 200A3 150, 225, 300A4 200, 300, 400AC Custom Range
Output Signal020 0–20mA420 4–20mA003 0–3VDC005 0–5VDC010 0–10VDC
DT
Power Supply24U +24VAC/DC
U2 4 U
*Bipolar version available in mid 2000.
2.25"57.2mm
2.4"61mm
0.854"21.7mm
0.857"21.7mm
0.72"18.3mm
0.52"13mm
0.19"4.5mm dia.Typical of 2
0.36"9.1mm
0.52"13mm
2.4"61mm
3.53"89.7mm
3.044"77.3mm
1.18"30mm
0.125"3.2mm
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
Output
Setpoint
Range JumperNoneLOW MID HIGH
Typical of NOAC and NOAC-15
NCAC and NCAC-15 Similar
Typical of AS3M-CCDC (See page 16)
Typical of AS3M-AADC (See page 16)
SmartLEDR
Output
Setpoint
Range JumperNoneLOW MID HIGH SmartLED
R
Output
Setpoint
Range JumperNoneLOW MID HIGH SmartLED
R
SpecificationsPower Supply None — Self-poweredOutput Isolated Solid State SwitchOutput Rating 1.0A @ 240VAC (Standard Units),
15A @ 120VAC, 10A @ 240VAC (–15 Option)Off State Leakage ■ NOAC: NONE,
■ NCAC: 2.5mAResponse Time 0.04 to 0.120 SecondSetpoint Range ■ Fixed Core: 1–6, 6–40 & 40–175A
■ Split Core: 1.5–6, 6–40 & 40–200AHysteresis 5% of SetpointOverload ■ MODEL CONTINUOUS 6 SEC 1 SEC
■ 1–6A 150A 400A 600A■ 6–40A 150A 500A 800A■ 40–175A 210A 800A 1,200A
Isolation Voltage UL listed to 1,270VAC, tested to 5,000VACFrequency Range 6–100Hz, works on VFDsSensing Aperture ■ –FF Case: 0.55" (14mm) dia.
■ –SP Case: 0.85" (21.5mm) sq.Case UL 94V-O Flammability RatedEnvironmental –58 to 149°F (–50 to 65°C),
0–95% RH, non-condensingListings UL 508 Industrial Control Equipment
(USA & Canada), CE
MULTI-POLE VERSION (SEE PAGE 16 FOR DESCRIPTION):Switch Rating 0.15A @ 30VDCOff State Leakage ■ AADC: NONE
■ CCDC: 0.3mA (NC terminal only)
Connections
Example: AS3-NOAC-SP-NLAdjustable AC current switch, split core without indicating LED.
Output RatingNCAC Normally Closed, 1A @ 240VACNOAC Normally Open, 1A @ 240VAC
Case StyleFF Fixed Core,
Front Term.SP Split Core
AS3
Ordering Information
OptionsNL No LED15 15A @ 120VAC
outputNotes:■ Terminals are #6 screws.■ DC contacts are polarity sensitive.
LEDPOT
0.47"12mm
0.17"4.5mm int. dia.Typical of 2
1.650"27mm
0.125"3.2mm
0.55"14mm dia.
3.3"83.8mm
2.75"69.9mm
0.92"23.4mm
1.2"31mm
AS3M Only
1.75"45mm
0.95"24.1mm
2.18"55.4mm
AS3 SeriesPAGE 15
AS3 SeriesCurrent Operated Switches
2.25"57.2mm
2.4"61mm
0.854"21.7mm
0.857"21.7mm
0.52"13mm
0.22"5.7mm
0.52"13mm
3.53"89.7mm
0.188"4.5mm int. dia.Typical of 2
1.190"30.2mm
0.125"3.2mm
2.4"61mm
3.044"77.3mm
ApplicationsElectronic Proof Of Flow
—␣No need f or pipe or duct penetrations.— More reliable than electromechanical pressure or flow switches.
Conveyors— Detects jams and overloads— Interlocks multiple conveyor sections
Lighting CircuitsEasier to install and more accurate than photocells.
Electric HeatersFaster response than temperature sensors.
‘AS1’ Current Switches fromNK Technologies combine acurrent transformer, signalconditioner and limit alarm intoa single package. The AS1 serieshas an extended current inputrange, universal solid-stateoutputs and a wide frequencyresponse. Available in a splitcore case or two styles of solidcore cases.
Features■ Universal Output
—Solid state switch N.C. or N.O.works on AC or DC to 240VAC.
—Compatible with any automationsystem.
—Reduces inventory, installationand engineering costs.
■ Self-poweredCuts installation and operating costs.
■ Easily Adjustable SetpointSpeeds startup
■ Solid or Split Core CaseChoose the right version for eachinstallation.
■ Built-in Mounting BracketProvides the solid installationinspectors want.
■ UL, CUL and CE ApprovalAccepted worldwide.
Current Operated SwitchesCurrent Operated Switches
Current Operated Switches
AS1 SeriesAS1 Series
AS1 SeriesAS1 SeriesPAGE 10
LINE
Controller
Starter
DODigital
Out
DIDigital
In
FAN ON
NOT REQUIRED!
2nd Conduit, Wire, DP Switch, Pressure Tubing, Pipe Fitter, etc.
M
PerfectMatch for
AutomationSystems
AMPS
TIME
StartupInrush
Normal Operation Belt or Coupling Breaks
AMPS
TIME
StartupInrush
Normal Operation
Jam
MOTOR OFF
Overload or JamUnderload or Status
FF Case
SP Case
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
Current Operated SwitchesCurrent Operated Switches
ApplicationsElectronic Proof of Flow
— No need for pipe or duct penetrations.— More reliable than electro-mechanical pressure or flow switches.
Conveyors— Detects jams and overloads.— Interlocks multiple conveyor sections.
Lighting CircuitsEasier to install and more accurate than photocells.
Electric HeatersFaster response than temperature sensors.
AS3 Series ‘AS3’ Current Switches fromNK Technologies combine acurrent transformer, signalconditioner and a limit alarminto a single package.The AS3 Series has three jumperselected current input ranges,solid-state AC output and a widefrequency range. Available in asplit core or front terminal solidcore case.
AS3 SeriesAS3 SeriesPAGE 14AS3 SeriesCurrent Operated Switches
Greatwith
Relay LogicControl
LINE
Controller
Starter
DODigital
Out
DIDigital
In
FAN ON
M
Features■ Choice of Outputs
— Solid state switch N.C. or N.O.— 1A @ 240VAC.— 15A @ 120VAC.
■ Self-poweredCuts installation and operating costs.
■ Adjustable SetpointSpeeds startup.
■ Solid or Split Core CaseChoose the right version for eachinstallation.
■ Built-in Mounting BracketProvides the solid installationinspectors want.
■ UL, CUL and CE ApprovalAccepted worldwide.
AS3 Series
Example: AS1-NOU-SPAdjustable AC current switch, split core, with indicating LED.
Output RatingNOU Normally
OpenNCU Normally
Closed
Case StyleFF Fixed Core, Front Term.FT Fixed Core, Top Term.SP Split Core
AS1
Ordering Information
Connections
Notes:■ Terminals are #6 screws.■ Normally open contacts shown (NOU).■ Normally closed contacts similar (NCU).
2Output1Setpoint
Typical ofModels with LED
SmartLED
2Output1
Typical ofGo/No-Go Models
R
Current Operated Switches
SpecificationsPower Supply None — Self-poweredOutput Magnetically Isolated Solid-State SwitchOutput Rating ■ N.O. Version: 0.2A @ 240VAC or VDC
■ N.C. Version: 0.2A @ 130VAC or VDC■ Not polarity sensitive
Off State Leakage NoneResponse Time 0.120 SecondSetpoint Range ■ Fixed Core: 1–150A
■ Split Core: 1.5–150AHysteresis 5% of SetpointOverload ■ MODEL CONTINUOUS 6 SEC 1 SEC
■ –GO 250A 500A 1,000A (NOU)■ –GO 150A 400A 1,000A (NCU)■ All Other 150A 400A 1,000A
Isolation Voltage UL Listed to 1,270VAC, tested to 5,000VACFrequency Range 6–100HzSensing Aperture ■ –FF Case : 0.55" (14mm) dia.
■ –FT Case : 0.75" (19mm) dia.■ –SP Case: 0.85" (21.5mm) sq.
Case UL 94V-O Flammability ratedEnvironmental –58 to 149°F (–50 to 65°C),
0–95% RH, non-condensingListings UL 508 Industrial Control Equipment
(USA & Canada), CE
1.93"49mm
2.18"55.4mm
0.6"15mm
0.931"23.7mm
2.433"61.8mm
3.53"89.7mm
1.506"38.3mm
3.08"78mm
1.5"39mm
0.125"3.2mm
0.75"19mm
dia.
0.967"24.56mm
0.17"4.5mm int. dia.Typical of 2
LEDPOT
OptionsGO Go/No-Go Version
(Fixed Setpoint)NL No LED— With LED (Blank)
LEDPOT
0.47"12mm
0.17"4.5mm int. dia.Typical of 2
1.650"27mm
0.125"3.2mm
0.55"14mm dia.
3.3"83.8mm
2.75"69.9mm
0.92"23.4mm
1.2"31mm
Jumper
1.75"45mm
0.95"24.1mm
2.18"55.4mm
AS1 SeriesAS1 SeriesPAGE 11
FT Case
FF Case
AMPS
TIME
StartupInrush
Normal Operation Belt or Coupling Breaks
AMPS
TIME
StartupInrush
Normal Operation
Jam
MOTOR OFF
Overload or JamUnderload or Status
2.25"57.2mm
2.4"61mm
0.854"21.7mm
0.857"21.7mm
0.52"13mm
0.22"5.7mm
0.52"13mm
3.53"89.7mm
0.188"4.5mm int. dia.Typical of 2
1.190"30.2mm
0.125"3.2mm
2.4"61mm
3.044"77.3mm SP Case
-
NK Technologies ■ 800/959-4014NK Technologies ■ 800/959-4014
know your power . . .because with knowledge comes control.
know your power . . .because with knowledge comes control.
ASM Series
ApplicationsConveyors (–OL option)
— Detects jams and overloads.— Interlocks multiple conveyor
sections.
Electronic Proof of Flow (–UL option)— No need for pipe or duct
penetrations.— More reliable than electro-
mechanical pressure or flow switches
Lighting or Heating Circuits(–UL option)Fast and easy installation.
Pump Protection (–OU option)Provides overload (jams) andunderload (suction loss) indication.
Self-Calibrating Current Switches
‘ASM’ Current Switches fromNK Technologies combine acurrent transformer, signalconditioner and self-calibratinglimit alarm into a single package.The ASM Series has an extendedcurrent input range, universalsolid-state outputs and a widefrequency response. Available ina split core or top terminal solidcore case.
OperationChoose the right operating type foryour application:
Features■ Self Calibrating Switch
Speeds startup.
■ Self-poweredCuts installation costs.
■ Choose the Operating Style thatMatches your Application— Status alarms on underload,
proving that equipment isrunning properly.
— Overload protects against jamsand blockages.
— Operating window provides bothstatus and overload in a singledevice.
■ Universal OutputAC or DC switching meanscompatibility with any automationsystem.
■ CompactFits in starters and panels.
■ UL, CUL and CE ApprovalAccepted worldwide.
TIME
AMPS
Overload Trip
Jam or Blockage
Broken Belt or Coupling
Operating Load
Underload Trip
+15%
–15%
TIME
AMPS
Overload Trip
Jam or Blockage
Operating Load+15%
TIME
AMPS
Broken Belt or Coupling
Operating Load
Underload Trip–15%
Self-Calibrating Current Switches
ASM SeriesASM Series
ASM Series
Self-Calibrating Current Switches
Status Monitoring (–UL option)proves operation.
Overload Monitoring (–OL option)protects equipment from jams and stalls.
Operating Window (–OU option)combines Status Monitoring andOverload Monitoring in one device.
SpecificationsPower Supply None — Self-poweredOutput Magnetically Isolated Solid-State SwitchOutput Rating ■ N.O. Version: 0.2 A @ 240VAC or VDC
■ N.C. Version: 0.2 A @ 130VAC or VDC■ Not polarity sensitive
Off State Leakage NoneResponse Time 0.2 SecondSetpoint Range ■ 1.5–150A (Fixed Core)
■ 2.8–150A (Split Core)Setpoint ■ Overload: +15% of Load (–OL)
■ Underload: –15% of Load (–UL)■ Operating Window: +/–15% of Setpoint
Hysteresis 5% of SetpointOverload MODEL CONTINUOUS 6 SEC 1 SEC
All 150A 500A 1,000AIsolation Voltage UL Listed to 1,270VAC, tested to 5,000VACFrequency Range 6–100HzSensing Aperture ■ –FT Case: 0.75" (19 mm) dia.
■ –SP Case: 0.85" (21.5mm) sq.Case UL 94V-O Flammability ratedEnvironmental –58 to 149°F (–50 to 65°C),
0–95% RH, non-condensingListings UL 508 Industrial Control Equipment
(USA & Canada), CE
Connections
1.93"49mm
2.18"55.4mm
0.6"15mm
0.931"23.7mm
2.433"61.8mm
3.53"89.7mm
1.506"38.3mm
3.08"78mm
1.5"39mm
0.125"3.2mm
0.75"19mm
dia.
0.967"24.56mm
0.17"4.5mm int. dia.Typical of 2
LEDPOT
OutputCLR RUN Calib/
Alarm
R
ContactR
Notes:■ Terminals are #6 screws.■ Smart LED standard.■ NOU shown, NCU similar.
Example: ASM-NOU-OL-SPAdjustable universal AC current switch, normally open,self-calibrating overload operation in a split core case.
Output RatingNOU Normally OpenNCU Normally Closed
OperationOL OverloadUL Underload (Status)OU Over/Underload
(Operating Window)
ASM
Ordering Information
Self-Calibrating Current Switches
ASM SeriesPAGE 13
ASM Series
Case StyleFT Fixed Core, Top Term.SP Split Core
PAGE 12
FT Case
2.25"57.2mm
2.4"61mm
0.854"21.7mm
0.857"21.7mm
0.52"13mm
0.22"5.7mm
0.52"13mm
3.53"89.7mm
0.188"4.5mm int. dia.Typical of 2
1.190"30.2mm
0.125"3.2mm
2.4"61mm
3.044"77.3mm SP Case