By Anthony Moody Rhys Porter Nicolas Wilson. Background Objectives Design Normal Operation ...

16
Project 1 – Level Crossing By Anthony Moody Rhys Porter Nicolas Wilson

Transcript of By Anthony Moody Rhys Porter Nicolas Wilson. Background Objectives Design Normal Operation ...

Page 1: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Project 1 – Level Crossing

By Anthony MoodyRhys Porter

Nicolas Wilson

Page 2: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Background Objectives Design Normal Operation Logic Failure Issues and solutions Improvements

Overview

Page 3: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Level Crossing: Flags as indicators Patent of Level Crossing Electronic Bells Cross-Buck “X” sign

Background

Page 4: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

12 Digital Inputs 4 Inputs able to run as analog 6 Relay Outputs LCD Display Operating Buttons

Moeller 719-DC-RC

Functions:

Page 5: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Design and Implement a Level crossing using analogues available in the lab and Moeller

Fail safely and appropriately handle exceptional cases

Objectives

Page 6: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Fail Safe Moeller Easy “PLC” Power Supply Strobe Light as bells

Design

Page 7: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Proximity Based Train Detection Safety Conscious Design Verbose Fault/Warning Memory for

Diagnosis and Reporting Some Automatic Fault Recovery Intersection Obstruction Detection 10 effective outputs from 6 SSRs Emergency Stop Fail Safe on Controller Power Loss

Key Features

Page 8: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Output Wiring Diagram

Page 9: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Normal Operation Wait for train Trigger warning lights Lower boom gates Set train lights accordingly throughout As train leaves do in reverse order

Page 10: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Logic

Page 11: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Zone Based pseudoLogic

Page 12: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Simplified Underlying Logic

Page 13: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Loss of power to controller Sensor failure (boom gates) Emergency switch Obstructed intersection Train detection failure Erroneous train signals to boom gate

Failure & Exceptional Cases

Page 14: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Issue & Solutions Issue:

Limited outputs Solution:

Use external transistor with diode or gate

Issue: Potentiometer too sensitive

Solution: Use rheostat in series with resistor

Page 15: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

Moeller Expansion Module if required Active monitoring to larger control system

Possible Improvements

Page 16: By Anthony Moody Rhys Porter Nicolas Wilson.  Background  Objectives  Design  Normal Operation  Logic  Failure  Issues and solutions  Improvements.

HHSF & Questions