    INTECONT PLUS

    Solids Flow Meter

    Operating Manual

    BV-H2219 GB

  • 7/30/2019 BVH2219gb

    2/87

    Contacts, Copyright

    Sales: Tel.: +49 (0)6151 32 - 10 28Email: [email protected]

    Service: 24h Emergency hotline: +49 (0) 172 - 650 17 00 Discontinuous Weighing Technology+49 (0) 171 - 255 11 95 Continuous Weighing Technology

    Email: [email protected]

    Business Segments:

    Heavy Duty Weighing & Feeding

    Service Tel.: +49 (0) 61 51 32 - 26 23Service Fax: +49 (0) 61 51 32 - 32 70

    E-Mail: [email protected]

    Light Duty Weighing & Feeding

    Service Tel.: +49 (0) 61 51 32 - 25 72Service Fax: +49 (0) 61 51 32 - 20 72

    E-Mail: [email protected]

    Vibrating Machines

    Service Tel.: +49 (0) 61 51 32 - 10 75Service Fax: +49 (0) 61 51 32 - 30 96

    E-Mail: [email protected]

    Transport & Logistics

    Service Tel.: +49 (0) 61 51 32 - 24 48Service Fax: +49 (0) 61 51 32 - 13 69E-Mail: [email protected]

    Components & Spare Parts

    Service Tel.: +49 (0) 61 51 32 - 17 58Service Fax: +49 (0) 61 51 32 - 36 32E-Mail: [email protected]

    Copyright 2004SCHENCK PROCESS GmbH

    Measuring and Process SystemsLandwehrstrasse 55, D-64293 Darmstadthttp://www.schenck-process.com

    All rights reserved. Any reproduction of manual, regardless of method, without prior permission bySCHENCK PROCESS GmbH in writing, even by excerpt, is prohibited.

    Subject to change without prior notice.

  • 7/30/2019 BVH2219gb

    3/87

    Contents

    1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

    2. Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    Power ON 4

    LEDs 4

    Normal Displays 5

    Operation in Normal Mode 5

    Event Messages 6

    Function Distributor 8

    Display Check and Version Number 8

    Keyboard Mode 9

    START/STOP Feeder 9

    EasyServe Active/Deactive 9

    Batching Mode 10

    Loading By Sight 13

    Print Batch Report 13

    Zero Setting 15

    Read Parameters 17

    3. Control Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    4. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    5. Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    6. Setting Programs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    Function Distributor 27

    Calibrating Functions 28

    TW Tare 28

    CW Weight Check 29

    Simulation Mode 310405

    INTECONT PLUS VDM

    ContentsBV-H2219 GB I - 1

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    4/87

    Set Time 31

    7. Service Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    8. Parameterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    Select Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    Enter Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    Hardware Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    Load Default Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    Parameter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    9. Event Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

    System Message S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

    Electrical System E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

    Calibration C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

    Maximum H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

    Minimum L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

    Material Flow (Batch) B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

    Signal Lamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

    10. Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

    Test Plug 65

    11. Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

    Start Sources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

    Batching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

    Data Flow Charts: Signal Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

    Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

    Base Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

    Option Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

    Printer Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

    12. Replacement Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

    Replacing INTECONT PLUS FIP > INTECONT PLUS VEG . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 0405

    VDM INTECONT PLUS

    ContentsBV-H2219 GB I - 2

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    5/87

    0405

    INTECONT PLUS VDM

    ContentsBV-H2219 GB I - 3

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    This manual applies to software version VDM 20600-00.

    Edition : 0405

  • 7/30/2019 BVH2219gb

    6/87

    0405

    VDM INTECONT PLUS

    ContentsBV-H2219 GB I - 4

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    This page left intentionally blank

  • 7/30/2019 BVH2219gb

    7/87

    1. O ve rv ie w

    On INTECONT:

    INTECONT PLUS is designed as measuring and

    evaluation system for

    Belt WeighersSolids Flow MetersMass Flow MetersMass Flow FeedersWeighfeedersLoss-in-weight Feeders

    The system is supplied in 3 variants:

    1. Without option card (standard)

    2. With option card VFE 610Vfor additional input/outputs and printer

    3. With option card for fieldbusVSS021V : Modbus/S5VPB 020V: ProfibusVCB020V: DeviceNet

    The present manual applies to solids flow meters with

    controlled material prefeeder.

    Task:

    A Solids Flow Meter is designed for continuous

    weighing of materials with free flowing or fluidizable

    properties. Combined with a controlled material

    prefeeder, preset material amounts can be batched.

    For Further Reading:Fieldbus manual BVH2220

    S5-RK512 (3964R) FH 458

    Modbus (Comp) FH 525

    Display:

    5 x 7 - dot matrix with 6 mm character height

    Upper display left : running messageright : totalized amount in kg/h or

    t/h

    Lower display left : event messagesright : selectable

    flow rate, measured load,etc.

    Display can be changed over to American units.

    LEDs:

    2 green and 3 red LEDs

    Green LEDs : Ready

    Red LEDs : Error or limit value messages

    0405

    INTECONT PLUS VDM

    OverviewBV-H2219 GB 1

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    O Z1 = 362.5 kgE1 I = 1 0 0 0 kg/h

  • 7/30/2019 BVH2219gb

    8/87

    Keyboard:

    Flexible membranes with tactile touch

    gB Start/stop measurement

    TU Preselect lower displaySelect functions

    i Reset counter

    G FUNC Call function distributor andevent texts

    O DEL Acknowledge event message,delete input

    N ESC Abort function

    f ENT Start function,acknowledge input

    P DAT Prepare input, e.g. of setpoint

    B9 Enter parameters

    KL Enter sign and decimal point

    Some Definitions:

    I = Feed rate in kg/h or t/hMaterial amount per unit time

    Z = Totalized amount in kg or t

    Q = Measured loadLoad on load cells in kg

    Measuring Principle:

    Material is guided to measuring chute S free from

    whirls.

    Deflection force acts on load cell L/C whose output

    voltage is proportional to flow rate.

    INTECONT evaluates signal and computes flow rate

    and totalized amount.

    Measuring Technique:

    n Precision AC voltage amplifier with continuous

    correction of zero point and range.

    n Highly resolving analog-to-digital converter.The integrated method is designed to efficientlysuppress mains voltage interferences.

    n 16-bit microcontroller

    n Unlimited storage of counter readings,configuration and calibration data.

    0405

    VDM INTECONT PLUS

    OverviewBV-H2219 GB 2

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    9/87

    The schematic below shows all inputs and outputs.

    The sample mechanical equipment presents a systemequipped with crossed flexure strip.

    S = Measuring chute

    L/C = Load cell

    M = Relay output for material prefeeder

    F, G = Relay output for full feed/dribblefeed changeover

    Z = External totalizing counter

    A = Analog display for feed rate or

    measured load

    SERIAL = Serial interface for printer and host

    computer

    24 V = Power supply

    ALARM = Relay output for ALARM

    MIN = Relay output for MIN limit value

    MAX = Relay output for MAX limit value

    ACK = Acknowledge event messages

    EXT INPUT = External interrupt input

    ON = Relay output, scale started

    START/STOP = Start and stop scale

    Release = Release input

    0405

    INTECONT PLUS VDM

    OverviewBV-H2219 GB 3

    Transmissionto third partiesand reproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    O Z1 = 362.5 k gI = 1498 kg/h

  • 7/30/2019 BVH2219gb

    10/87

    2. C on tr ol

    Power ON

    During power failure

    all counter readings

    counter pulses still to be output

    preselected normal displays,

    Service values, e.g. ON-time

    are stored for an unlimited time.

    The internal clock continues running for approx. 5

    days.

    After power-up, an automatic display and lamp test is

    performed, followed by the display version number,

    then by normal displays.

    Message E1

    reports power failure .

    Message can be configured as ALARM or WARNING.

    ALARM: Red LED X and symbol E1 flash.

    Acknowledge message before startingscale.

    WARNING: LEDX remains dark, symbol E1 doesnot flash.No acknowledgement required.

    Start scale manually or automatically.

    O Acknowledge event message.

    LEDs

    a (green) POWER OKlit if all power supplies are OK.

    b (green) CPU OKlit if microprocessor is ready tooperate.

    X (red) ALARMflashes if an Alarm is available.In addition, the event code is

    shown in lower display line.

    MIN (red) MIN LIMIT VALUElit if feed rate limit value isexceeded down.

    MAX (red) MAX LIMIT VALUElit if feed rate limit value isexceeded up.

    READY: The two green signal lamps light;no Alarm is available.

    0405

    VDM INTECONT PLUS

    ControlBV-H2219 GB 4

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    Z1 = 2 5 0 0 kgE1 I = 0 kg/h

    Z1 = 2 5 0 0 kgE1 I = 0 kg/h

  • 7/30/2019 BVH2219gb

    11/87

    Normal Displays

    Upper DisplayLeft : Running message and operating modes.

    Rotating point indicates that totalizationand material prefeeder are active.

    Right : Totalizing counter 1

    Operating Modes

    Lower Display

    Left Event reported by alphanumeric code,e.g. E1 for power failure.

    Right Selectable

    TU Select display

    Counter Z1 Z1 = 5000 kg

    Counter Z2 Z2 = 6000 kgCounter Z3 Z3 = 1000 kgFeed rate I = 1000 kg/hFeed rate Ir = 50,00 % 1)Measured load Q = 10.000 kgMeasured load rel. Qr = 68,91% 2)Batch Zb, ZI, Zd, Nb, Zbn, Zdn 3)

    1) related to nominal feed rate

    2) related to nominal measured load

    3) see Batching Mode

    Display formats and units of Z1, Z2, Z3 and I can be

    selected individually.

    Operation in Normal Mode

    g Start totalization.Condition : External Release signal

    available (selectable).START_Source (B03) setto OP or Keyboard modeactive.

    Feature : Rotating point in left fieldof upper display

    B Stop totalization.Feature: points stands stillMeasured load continues being acquired.

    i Reset totalizing counters.

    1 Enter number of desired counter (1 or 2).FMZ No. : _Counter 3 cannot be reset. In case ofoverflow, counting resumes from 0.

    fAcknowledge input.

    N Delete faulty digits.

    TU Select lower display(see Normal Displays).

    O Acknowledge event message.

    GCall further functions, e.g. Display Event,

    Calibration.

    N Exit function distributor.

    0405

    INTECONT PLUS VDM

    ControlBV-H2219 GB 5

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    Z1 = 5 0 0 0 kgZ2 = 6 0 0 0 kg/h

  • 7/30/2019 BVH2219gb

    12/87

    Event Messages

    Definitions

    All important scale functions are internally monitored.

    Errors are reported by event message.

    For troubleshooting details, see chapter Event

    Messages.

    Message E1 Power Failure

    Message is output in left field of lower display in form

    of a group letter (e.g. E) and a number (e.g. 1). In

    addition, an explanatory text can be called up.

    The events are organized into 4 classes. The

    assignment of event to class can be selected using

    relevant parameter.

    n ALARM Display flashing and underscored.

    In addition, red signal lampXflashes.

    Totalization cuts off, scale is not

    operable.

    Start:

    First remove cause of fault and

    acknowledge message.

    Acknowledgement:

    If cause has not been removed

    yet, flashing stops, underscoresare deleted, but message is still

    available.

    If fault is remedied after

    acknowledgement, message

    automatically effaces.

    n WARNING 1 Display permanent and

    underscored.

    Totalization continues.

    Acknowledgement:

    If fault has not been remedied yet,

    underscore is faded out.

    n WARNING 2 Display permanent, not

    underscored.

    Acknowledgement:

    Not required.

    n IGNORE No monitoring of events, save

    MIN/MAX messages and deviation

    via contact outputs and signal

    lamps.

    If several events occur at the same time, the event

    with the highest priority is displayed first.

    Priority: Alarm, Warning 1, Warning 2.

    Operation

    O Acknowledge all available events ofclasses Alarm and Warning 1.If several events are available,acknowledge same one after the other.

    To display event texts:

    G Call function distributor.

    TU Scroll Display Events into lower displayfield (normally not required).

    f Select function.

    0405

    VDM INTECONT PLUS

    ControlBV-H2219 GB 6

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    Z1 = 2 5 0 0 kgE1 I = 0 kg/h

  • 7/30/2019 BVH2219gb

    13/87

    Display shows:

    Name e.g. No Release

    Code e.g. S2

    and hint e.g. Parameter M04

    of respective event.

    The hint informs the service staff of the relevant

    parameter. The consecutive number relates to the

    priority sequence.

    TU View several events.

    N Return to normal displays.

    List of Events

    The list is sorted by display priority.

    System Message S S1 Memory Error *

    S2 No Release

    S3 Maint. Scale Run

    S4 Maintenance Int. Elec

    S7 Simulation Active

    S9 Data Link Host

    Batching B B1 Out of Tolerance

    B9 Linearization

    Electrical System E E1 Power FailureE6 External Input

    Calibration C C1 L/C Input*

    C5 Tare Corr. > MAX

    Maximum H H1 I >MAX

    H4 L/C Input > MAX

    Minimum L L1 I < MIN

    L4 L/C Input

  • 7/30/2019 BVH2219gb

    14/87

    Function Distributor

    The function distributor lets you call further functions

    and/or dialogs.

    G Call function distributor.If no event is available, display shows thefunction selected last. If an event isavailable, the Display Events function isdisplayed.

    f Start function.

    N Return to normal displays and/orabort function.

    TUMove through function distributor.

    Display Events EDisplay CheckSTART/STOP FeederService ValuesSTART/STOP KEYB. MODESelect Batch BEasyServe active/deactiv>0< Zero SetProgrammingCalib.Functions SPrint FMZ

    Read ParametersEnter Parameters SLoad Default Par. SPrint ParametersPrint Stat. Rep.

    START/STOP SimulationTW: TareCW: Weight CheckSet Time

    Programming and Calibrating Functions lead to

    further menus you can move through using cursor

    keys.

    B = If batching mode is selected, additionalfunctions can be accessed in maindistributor.

    Abort BatchDeselect BatchBatch NumberPrint BatchReload

    S = Calibrating functions accessible after

    password input.Prompt is output after call of function

    E = Only if an event is available

    With opposed functions, e.g. START/STOP, only the

    one currently availabe can be reached.

    Moving in function distributor does not limit any

    scale-specific functions.

    Display Check and Version Number

    This function lets you check displays and signal

    lamps.

    G

    TU

    f

    Call Display Check function.1. All display elements rhythmically

    flash.2. Version number is displayed for

    approx. 10 s.Test terminates automatically.

    Example:

    VMD : Solids Flow Meter 20600-00 : Version number

    0405

    VDM INTECONT PLUS

    ControlBV-H2219 GB 8

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    FunctionDisplay Events

    I N T E C O N T P L U SVDM 20600-00 2063

  • 7/30/2019 BVH2219gb

    15/87

    Keyboard Mode

    This function lets you shift the selected control source

    for START/STOP to the INTECONT keyboard.

    After deselection of Keyboard mode, the former

    source is active again.

    Upon changeover from external source (e.g. serial) to

    keyboard, START/STOP status is maintained.

    In reverse direction, the external signals are active.

    GT Call function distributor.Select START Keyboard Mode orSTOP Keyboard Mode function.

    Display feature:

    You will know Keyboard mode by the square in the left

    upper display field.

    START/STOP Feeder

    The START/STOP Feeder function lets you start and

    stop material prefeeder.

    In started state (ON), INTECONT controls prefeeder.

    The normal Start/Stop commands cannot be used.In Stop state, material flow is interrupted and scale

    can be tared, etc.

    GT Call function distributor.Select Start Feeder or Stop Feederfunction.

    f Start function.

    EasyServe Active/Deactive

    The EasyServe Active/Deactive functions let you

    control your INTECONT using the EasyServe PC

    service tool.

    GT Call function distributor.Select EasyServe Active function

    To set communication parameters, useBlock Q.

    Note: Upon power failure, the current status isstored, i.e. EasyServe Active functionneeds not be re-called.

    Connection to PC can also be made using a 9-pole

    SUB-D connector on X4 (RS 232 only) or a Phoenix

    connector on X5 (RS232, RS422 or RS485).

    See also Wiring Diagram in chapter DETAILS.

    0405

    INTECONT PLUS VDM

    ControlBV-H2219 GB 9

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    16/87

    Batching Mode

    Batching mode is used to feed a defined amount of

    material. When batch setpoint is reached, batching

    operation is complete.

    0 Start batch, open prefeeder.

    1 Abort batch at any timeand

    2 resume.

    3 Change over to dribble feed by reducing prefeederoutput.

    4 Cut off prefeeder.

    5 Batch setpoint is reached.

    Additional Displays

    Upper display: If batching mode is selected, totals

    sign G.

    is displayed left of running

    message.

    The square indicating Keyboard

    mode is omitted.

    Lower display:

    TU Use cursor keys to scroll 3additional values into display field.

    1. Zb = Batch setpoint

    2. ZI = Batch actual value

    (amount already

    discharged)

    3. Zd = Batch residual value

    (amount still to be

    discharged)

    Zd = Zb-ZI

    4. Nb = Consecutive batchnumber.

    To set start value, use

    Batch Number

    function.

    Before start of a batch, ZI and Zd indicate the

    amounts fed out during previous batch.

    Batching mode deselected (Deselect Batch

    function), displays are disabled but can be used again

    upon next selection.

    Display format corresponds to the format of Counter

    1.

    Select Batching Mode

    Selection of Batching mode enables batching,

    however, no batch is started yet.

    Condition: Scale OFF

    G Call function distributor.

    TU Scroll Select Batch function into displayfield.

    f Select function.

    System prompts for input of batch setpoint.

    If batch is selected from external PC, setpoint input is

    omitted.

    0405

    VDM INTECONT PLUS

    ControlBV-H2219 GB 10

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    EO Z1 = 2 5 0 0 kgZ2 = 4 0 0 kg

  • 7/30/2019 BVH2219gb

    17/87

    Enter Setpoint

    Prompt for setpoint input is output automatically uponselection or can be started in manual when batch is

    complete (scale OFF).

    If Batching mode is deselected or a batch is running,

    no input is possible.

    If batch setpoint is preset via fieldbus (Parameter I07

    Batch Source=FB), no input is possible either. This

    also applies to input of batch number and reload

    setpoint.

    P Prepare setpoint input.

    19 Enter setpoint.Max. 9 digits including decimal point.The unit is that of Counter 1.

    f Acknowledge input.

    N Abort input; old setpoint is maintained.

    O Delete faulty digits.

    Start and Abort

    g Start batch, process starts.Display ZI : moves from 0 towards

    setpointDisplay Zd : moves from setpoint

    towards 0

    B Abort batch.

    Batching continues upon next Startcommand.

    Deselect Batch

    Lets you deselect Batching mode, i.e. mode is removedfrom available functions.

    Totals sign disappears from upper display, batchingvalues ZI, Zd, Zb and Nb are not longer available but

    remain stored.

    Conditions: Batch complete, or aborted using

    Abort Batch function, scale OFF.

    GTf

    Call function distributor.Select Deselect Batch function.

    Acknowledge.

    The Select Batch function lets you reactivate

    batching mode.

    The old ZI, Zd , Zb and Nb values can be viewed

    again.

    0405

    INTECONT PLUS VDM

    ControlBV-H2219 GB 11

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    EO SetpointZb = - - - - - - kg

  • 7/30/2019 BVH2219gb

    18/87

    Abort Batch

    Lets you abort a running batch, i.e. batchingimmediately stops.

    Batching mode remains selected.

    New batch starts upon next start command, old batch

    is not resumed.

    The Reload function lets you complete old batch.

    GT Call function distributor and select AbortBatch function.

    f Acknowledge.

    You can also abort batch using contact O02.

    Reloading

    Lets you add a specified amount to a complete batch.

    Conditions : Running batch complete, scale

    OFF. No batch report.

    Display ZI : Batch actual value increments from

    value achieved.

    Display Zd : Batch residual value keeps valueachieved.

    Display Zbn : Make-up setpoint

    Display Zdn : Batch residual value of make-up

    amount.

    Zdn = Zbn - make-up amount

    reloaded

    All displays can be scrolled into lower display field.

    Zdn and Zbn are available only until start of next

    batch.

    GT Call function distributor.Select Reload function.

    f Acknowledge function.System prompts for input of reloadsetpoint in kg or t.The unit is that of counter 1.

    P Change setpoint Zbn before start ofreloading.

    gB Start or abort reloading.

    If reloaded batch is complete, next Start command

    starts a normal batch.

    To repeat reloading, re-call function.The Abort Batch function lets you also abort

    reloading.

    Batch Number Nb

    Enter batch number. Number increments by 1 upon

    start of every new batch.

    Number is printed in batch report and can be viewed

    in lower display.

    Reloading operations belong to previous batch and

    are not counted.

    GT Call function distributor.Select Batch Number function.

    f Acknowledge.Prompt for input ofNb = - is output.

    f Acknowledge input.

    N Abort input.Old number is maintained.

    You can also change current number during batching.

    0405

    VDM INTECONT PLUS

    ControlBV-H2219 GB 12

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    19/87

    Loading By Sight

    Batch report can be printed only if a batch is complete

    (setpoint reached).

    If you wish to batch an amount not previously

    determined and print the result, follow these steps:

    1. Call Select Batch function.

    2. Select very high batch setpoint, e.g. 999999999 kg.

    3. Scroll batch actual value ZI into lower display field.

    4. Start scale.

    5. If amount ZI is reached, stop scale.

    6. Call Stop Batch function.

    7. Start printing (see Print Batch).

    The Reload function can be performed only before

    print command.

    For next batch, follow steps 4...7.

    Print Batch Report

    The printing functions require an option card to be

    present.

    Print Batch

    Start of printout disables the Reload function for the

    batch in question.

    Function can be called only in Batching mode.

    Printing can be started:

    1. Manually via function distributor2. Automatically, after each complete batch

    (Parameter I 06).

    GT Call function distributor.Select Print Batch function.

    f Start function.

    N Abort printing.

    Batch Report

    07.07.03 : Date and timeBatch setpoint: Preset batch amountBatch act. value: Amount batchedCounter 1 : Totalizing counter 1Counter 2 : Totalizing counter 2Batch number : Consecutive number NB of scaleEvents : Events available during printout

    0405

    INTECONT PLUS VDM

    ControlBV-H2219 GB 13

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    07.07.03 11:45:10

    Batch setpoint 0.150 t

    Batch act.value 0.150 t

    Counter 1 0.806 t

    Counter 2 806.47 kg

    Batch number 40

    Events

    E1 Power Failure M01

  • 7/30/2019 BVH2219gb

    20/87

    Print Counter Readings (FMZ)

    Identical with batch report; however, the title isQuantity Report.

    Batch number, setpoint and actual value are printed

    only if Batching mode is selected.

    To call:

    1) Select Print FMZ function.Unlike Print Batch, report canalso be printed duringbatching.

    2) Automatically upon each event printout(Parameter J 02 = YES)

    Print Parameters

    Lets you print out parameter list complete with current

    values.

    Parameter values varying from default settings are

    cross-marked (*).

    As Appendix, a list of possible events and current

    hardware assignment is printed.

    GT Call function distributor.Select Print Parameters function.

    f Start function.

    N Abort printing at any time.

    Print Events

    Parameter J 02 lets you decide whether event

    messages are to be printed or not.

    Eligible settings :

    1. No printout (NO)

    2. Print events (Error)

    3. Print events and counter readings (YES)(see Batching)

    L1 : Event code

    W1 : Message class, e.g. WARNING 1

    > : Event has occurred

  • 7/30/2019 BVH2219gb

    21/87

    Voltage ON-time

    Total voltage ON-time

    Scale ON-Time

    Total ON-time of measurement and INTECONT

    Events after last status report

    Number and type of events since last report printout.

    If report is printed for the first time, counting starts

    from power-On.

    Counters 1, 2, 3

    Totalizing counters 1-3

    Zero Setting

    The zero setting program lets you acquire the

    measuring systems zero point error over a settable

    time.

    The acquired value is used to correct the current

    measuring result during operation.

    Effects:

    1. During zero setting, totalizing counters stop.

    2. Analog value is set to elevation value.

    3. Events continue being monitored.

    Conditions:

    1. No material flow

    2. Scale turned off(prefeeder, if present, closes).

    Follow these steps:

    G Call function distributor.

    TU Scroll >0< (zero set) into lower displayfield.

    f Start function.

    N Abort function at any time.

    0405

    INTECONT PLUS VDM

    ControlBV-H2219 GB 15

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    STATUS REPORT INTECONT PLUS

    03.06.03 13:37:12

    Software : VMD 20600-00 2063Hardware version : 1Option card version : 1Station address : 1- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

    Mode OP : NOMode Simulation : NOScale ON : NO

    Alarm : NOVoltage ON-time : 35 hScale ON-time : 23 hCounter 1 : 5635 kgCounter 2 : 6 tCounter 3 : 6 t-----------------------------------------------------------

    Events after last status report

    2 * S02 No Release

  • 7/30/2019 BVH2219gb

    22/87

    Program Running:

    Upper display : Residual run time in % of total run

    time

    Lower display : Zero point error related to nominal

    measured load

    N Abort program at any time.

    Program Complete:

    Upper display: Deviation of zero point from

    previous zero setting operation

    in % of nominal measured load

    dev = + : error increased

    dev = - : error decreased

    Lower display: Mean value of total zero point in %

    of nominal measured load

    f Accept Tarkor result and enter intoParameter D 05.

    N Reject result, i.e. scale not tared.

    Special Messages:

    1. OFF INTECONT is still ON

    2. ABORTED Zero setting result has not beaccepted

    3. VALUE TOO BIG Zero setting result hasexceeded specified limits(Parameter H03).Result is rejected.

    0405

    VDM INTECONT PLUS

    ControlBV-H2219 GB 16

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    0o Dev. 2.45%Tarkor 3.50 %

    0o >0< 70 %Tarkor 1.12 %

  • 7/30/2019 BVH2219gb

    23/87

    Read Parameters

    Parameters are defined as variable characteristics or

    data used to match the INTECONT to the application.

    Parameter input is protected by password.

    The Read Parameters function lets you view all

    parameters without jeopardizing the operating safety.

    The parameters are organized into function blocks A ,

    B... and consecutively numbered within a block.

    GT

    f

    Scroll Programming function intodisplay field and acknowledge.

    Tf Select Read Parameters sub-function.

    Display shows title of first parameter block.

    TU Move through parameter blocks A, B...

    fT Move through parameters within a block.

    N Return to blocks.

    N Return to normal displays.

    For details, see Enter Parameters.

    0405

    INTECONT PLUS VDM

    ControlBV-H2219 GB 17

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    Nominal Feed RateB02 1000.0 kg/h

    Scale DefinitionsBlock: A

  • 7/30/2019 BVH2219gb

    24/87

    This page left intentionally blank

    0405

    VDM INTECONT PLUS

    ControlBV-H2219 GB 18

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    25/87

    3. C o nt r ol O v er v ie w

    Status Displays (Upper Display Field)

    In normal mode, totalizing counter Z1 is displayed.

    Point rotates Scale (totalization) started

    Control Keys:

    gB Start/stop totalization (if selected)

    U

    T

    SCROLL Select lower display and functions.1. Counters Z2, Z3 4. Measured load Q2. Feed rate I 6. Batch displays Zb, ZI, Zd, Nb, Zbn, Zdn3. Feed rate Ir in %

    iRESET Reset totalizing counter.

    1. Enter number of desired counter (1 or 2). Counter 3 cannot be reset.2. Acknowledge input with ENTER key, or3. Abort with ESCAPE key, or4. Delete faulty input with DELETE key

    G FUNCTION Call function distributor and event messages.1. Select desired function using SCROLL keys.

    If an event is available, Display Events function is already selected.2. Activate function with ENTER key.3. Pass through available event messages with SCROLL keys.4. Return to normal display with ESCAPE key

    0405

    INTECONT PLUS VDM

    Control OverviewBV-H2219 GB 19

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    O Z1 = 362.5 kg-- I = 100 k g/h

  • 7/30/2019 BVH2219gb

    26/87

    0405

    VDM INTECONT PLUS

    Control OverviewBV-H2219 GB 20

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    O DELETE Acknowledge event message, delete input.

    N ESCAPE Abort function, return to normal displays.

    f ENTER Acknowledge input, e.g. parameter.Start function, e.g. Display Events (see FUNCTION).

    P DATA Prepare input, e.g. parameters

    Lower display field shows event message, if any, e.g. symbol S2 = No Release.

    List of Events

    sorted by display priority.

    System Messages S1 Memory Error *

    S2 No Release

    S3 Maint. Scale Run

    S4 Maintenance Int. Elec

    S7 Simulation Active

    S9 Data Link Host

    Batching B1 Out of Tolerance

    B9 Linearization

    Electrical System E1 Power Failure

    E6 External Input

    Calibration C1 L/C Input *

    C5 Tare Corr. > MAX

    Maximum H1 I >MAX

    H4 L/C Input > MAX

    Minimum L1 I < MIN

    L7 WZ Eingang

  • 7/30/2019 BVH2219gb

    27/87

    4. T e ch n ic a l D a ta

    n Panel-mounting unit: VEG 20600/20610Front panel :96 x 288 mm

    Panel cut-outs : 88 x 282, wall thicknessmax. 10 mm

    Mounting depth : min. 225 mm(including 50 mm forconnectors)

    Protected to : IP 20, front to IP 65

    Material : plastic grey to RAL 7022

    Display : fluorescent, 2 lines of 20characters, 6 mm high

    Keyboard : f lexible membranes withtactile touch

    Signal lamps : LEDs, 2 x green, 3 x red

    Power supply : 24 V(DC) +50 % -25%,max. 1 A,no fuse, pole-reversalprotective circuit

    Ext. power supply : 90...264V/ 50HZ...60HZ

    n Surface-mounting unit: with panel mounting unitVEG 20...

    n Wall-mounting housing

    Measuringsystems : width x height x depth

    410x330x236mm

    Feedingsystems : width x height x depth

    500x600x300mm

    Protected to : IP 65

    Material : steel sheet, 1.5 mm, greyVoltage supply : 90...264V/50Hz...60Hz

    Extension : Feed unit controller

    n Environment

    Temperature : -25 C ... +45 C,tested to -40C

    Humidity : Class F (DIN 40 040) *

    Interferenceimmunity : to IEC 801

    Interference

    suppression : to VDE 871, EN 55 011

    Housing safety : to IEC 348

    EC recommen-

    dations : CE label

    * Tropical version (class R) upon request

    n Storage temperature

    -40 C ... +60 C

    n Connectors

    Plug/screw connectors (Phoenix Combicon),non-confusible

    n Control outputs

    Number : 8 N/O relay contacts

    Base board : 3

    Option card : 5

    Load : max. 230 V(AC)8 A resistive load, 1 Ainductive

    If error message CPU Not OK is output, all contacts

    open.0405

    INTECONT PLUS VDM

    Technical DataBV-H2219 GB 21

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    P = 100.00 kg/hI = 0 kg/h

  • 7/30/2019 BVH2219gb

    28/87

    n Control inputs

    Number : 5Base card : 3

    Option card : 2

    Type : 24 V(DC) +/-30 %, 5 mA,galvanically isolated

    n Control inputs (NAMUR)

    Number : 2

    Type : NAMUR (DIN 19234),short-circuit and cablebreakage monitoring

    n Analog output

    Number : 2

    Base card : 1

    Option card : 1

    Current : raise ...20 mA impressed

    Raise : 0...

  • 7/30/2019 BVH2219gb

    29/87

    n Load cell connection

    Voltage supply : +/- 6 V AC (+/-3 %)(apr. 66 Hz),short-circuit-proof

    Measuring cycle : 100ms

    Resolution : 24 Bit

    Load : R (load cell) = min. 80 ohms

    Cable length : max. 30 % voltage drop,max. 500 m

    Measuring range : -20mV....+50mVwith VLW:-1.6mV...min. 32mV

    n Serial interface for service PC

    Number : 1

    Type : RS232; RS422 or RS 485max. 19200 baud

    Data format : 8 data bits, 1 stop bit, oddparity changeable to even orno

    Isolation : galvanically non-isolated

    Connectors : Phoenix MSTB, contactspacing 3.5 mm, max. 1.5mm2 or 9-pole D-Sub HD20

    0405

    INTECONT PLUS VDM

    Technical DataBV-H2219 GB 23

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    30/87

    0405

    VDM INTECONT PLUS

    Technical DataBV-H2219 GB 24

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    This page left intentionally blank

  • 7/30/2019 BVH2219gb

    31/87

    5. C ha ra ct er is ti cs

    n Power Failure

    Scale data, calibration values, counter readings and

    pulses pending remain stored after power failure for

    an unlimited period of time. The internal clock

    continues running for approx. 5 days.

    n Dialog Languagefor error messages, operation, and serviceprograms.

    Eligible : DEUTSCHENGLISHFRANCAISESPANOLITALIANO

    n Units (selectable)

    SI units : kg, kg/ht , t/h

    m , cmNON-SI units : lb , lb/h

    t , t/hf , inch

    (see Parameter Shortlist)

    n Start/Stop Totalizing Counter

    Select using Parameter B03.

    n Release, Emergency Stop

    Functions are realized using a digital input O01.

    n Displays

    Upper display : Totalizing counter 1

    Lower display: Totalizing counters 2...3Feed rate absolute IFeed rate relative IrMeasured load absoluteMeasured load relativeBatch data

    Select lower display using cursor keys.

    n Signal Lamps (top down)

    VOLTAGE OK (green)PROCESSOR OK (green)ALARM (red)MIN (red) feed rate MIN limitMAX (red) feed rate MAX limit

    n Event Messages

    Events and faults are displayed in form of analphanumeric code.Call clear text of events via keyboard.Events are organized into Alarms, and Warningswith and without acknowledgement. Alarms stopscale, warnings dont.

    All alarms are additionally reported via relayoutputs.

    n Operating Philosophy

    Operator prompting through multi-level menus.Important configuration and calibration functionsare protected by password.

    0405

    INTECONT PLUS VDM

    CharacteristicsBV-H2219 GB 25

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    32/87

    n Zero Setting

    Zero setting is performed by an automatic program.No material is required.Program can be started

    1. manually via keyboard2. automatically with closed prefeeder

    Max. admissible zero setting amount is monitored.

    n Taring

    Designed to zero the basic tare load, the taringprogram on principle has the same function as thezero setting program. However, tare elevation is notmonitored, and the call is protected by password.

    n Zero Drop Out

    Suppresses totalization upon measurementsaround zero point, so that counter stops with smallfeed rates.Deselect function if not desired.

    n Display Filters

    can be defined individually for feed rate andmeasured load.

    n Maintenance Hints

    through display of event s

    1. Voltage ON-time

    2. Scale ON-time

    n Adaptions

    The electrical system needs not be redesigned noradapted.

    n Calibration

    Calibration as such is not required. All you have todo is enter some constructional data of load cells,speed transducer, belt inclination, etc. INTECONTuses these data to compute all requisite displaynormalisations.Check, or recalibration, canbe effectedin twoways:

    a) Using material

    Enter check result into INTECONT, andmeasurement value will be corrected.

    b) Using check weight

    A special check program lets you checknormalizations, and correct them if technicaldata or not exactly known. In later operation,program can also be used to show technicalmodifications.

    n Digital Inputs

    Number Name Default

    O03

    O01B03O02O02

    DI Ackn. Events

    ReleaseSTART SourceDI Stop BatchDI Ext. Event

    DI1

    DI2-(OP)--

    n Digital Outputs

    Nummer Name Default

    P04P05P01

    P02P03P07P08P06

    DO I-MINDO I-MAXDO ALARM

    DO Prefeeder ONDO Feeder ONFull FeedDribble FeedDO Batch Active

    D01DO2D03

    D06D05---

    0405

    VDM INTECONT PLUS

    CharacteristicsBV-H2219 GB 26

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    33/87

    6. S e tt i n g P r og r am s

    Function Distributor

    The function distributor lets you call further functions

    and/or dialogs.

    G Call function distributor.If an event is available, Display Eventsis displayed; if no event has occurred,display shows function selected last.

    f Start function.

    N Return to normal displays, or abortfunction.

    TU Move through function distributor.

    Display Events EDisplay CheckSTART/STOP FeederService ValuesSTART/STOP Keyb. ModeSelect Batch BEasyServe active/deactiv>0< Zero SetProgramming

    Calib.Functions SPrint FMZ

    Read ParametersEnter Parameters SLoad Default Par. SPrint ParametersPrint Stat. Rep

    START/STOP SimulationTareCW: Weigh CheckSet Time

    Programming and Calibration functions lead to furthermenus you can move through using cursor keys.

    B = If Batching mode is selected, additionalfunctions can be accessed in maindistributor.

    Abort BatchDeselect BatchBatch NumberPrint BatchReload

    S = Calibrating functions protected bypassword. Prompt for password input isoutput after call of function.

    E = If an event is available.

    With opposed functions, e.g. START/STOP, only the

    one currently accessible can be called.

    Moving through function distributor has no effect on

    weighing functions.

    0405

    INTECONT PLUS VDM

    Setting ProgramsBV-H2219 GB 27

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    F u nc t i o nD i s p l a y E v e n t s

  • 7/30/2019 BVH2219gb

    34/87

    Calibrating Functions

    Menu item Calibration Functions lets you access 3

    functions:

    1. TW Tare

    2. CW: Weight Check

    2. Set Time

    All functions are protected from unauthorized use bypassword.The operating sequence is the same for all programs.

    GCall function distributor.

    TUf Scroll CALIBRATIONFUNCTIONS into lower displayfield and acknowledge.

    . . . . . .f Enter password 07734.

    Display shows one of the setting programs, e.g. TW:Tare.

    f Start setting program.

    N Return to normal displays.For apr. 2 min., Calibrationmenu can be recalled without

    password input.

    TW Tare

    The taring program acquires zero point error of

    complete measuring system over a settable time

    (Parameter C 01, default = 30 s).

    INTECONT uses this value to correct measuring

    result during operation.

    In contrast to zero setting program, zero setting range

    is not monitored nor limited.

    Taring program deletes the zero setting result.

    Effects: 1. During taring, no totalizationtakes place.

    2. Analog output is set toelevation value.

    3. Events continue beingmonitored.

    Conditions: 1. No material flow.2. Scale cut off

    (prefeeder closed, if present).

    Follow these steps:

    Gf Function distributor, Calibration functions,password (see Calibration Functions).

    TU Scroll TW: Tare function into lowerdisplay field.

    f Start function.

    N Abort at any time

    0405

    VDM INTECONT PLUS

    Setting ProgramsBV-H2219 GB 28

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    CALIBRATION FUNCTIONSTW: Tare

  • 7/30/2019 BVH2219gb

    35/87

    Program running:

    Upper display: Residual run time in % of total run

    time

    Lower display: Continuously meaned tare in % of

    nominal measured load

    Program complete:

    Upper display : Deviation of tare value from

    previous taring operation

    in % of nominal measured load

    dev = +: tare increased

    dev = - : tare decreased

    Lower display : Mean value of total tare

    in % of nominal measured load

    f Accept taring result and enter value intoParameter D 04.Tare correction (D05) is set to zero.

    N Reject result, i.e. scale not tared.

    Special Messages:

    1. STOP if INTECONT is still started

    2. ABORTED if taring result is not acquiredyet

    CW Weight Check

    This program lets you check the INTECONT

    measuring range.

    Load measuring system with a known check weight

    and acquire load cell load mean value over a certain

    time.

    INTECONT compares result with specified setpoint

    and displays value.

    No automatic correction takes place.

    Effects:

    1. During run time, no totalization takes place.

    2. Analog output is set to elevation value.3. Events continue being monitored.

    Conditions:

    1. Taring or zero setting performed

    2. Effective check weight entered into Parameter C 05

    3. Check weight applied in provided point

    4. Scale cut off

    Sequence:

    Gf Function distributor, Calibration function,password (see Calibration Functions)

    TU Scroll CW: Weight Check into lowerdisplay field.

    f Start program.

    N Abort at any time

    0405

    INTECONT PLUS VDM

    Setting ProgramsBV-H2219 GB 29

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    >0< Dev. 2.45 %Tare 3.50%

    >.

    >0< TW: 9 0. 2 %T a r e 5 2. 3 5

  • 7/30/2019 BVH2219gb

    36/87

    Program running

    Upper display : Residual run time in % of total run

    time

    Lower display : Continuously meaned SET/ACT

    measuring result

    Program complete

    Upper display : ACTUAL measured load in kg

    Lower display : Mean value COR of SET/ACT over

    total run time

    fN Exit program.Since result is not acquired automatically,

    the two keys are equivalent.

    Special hints:

    1. STOP if INTECONT is still ON

    2. ABORTED after exit of program

    * Lets you check scale zero point without check weightDisplay format: xxxxxxx,yy kg

    Evaluating result:

    Error < 1 % : COR = 0.99...1.01Scale OK, no further action

    required.

    Error < 5 % : COR = 0.95...1.05

    Enter KOR value into Parameter D

    02 .

    This makes good sense only if

    parameter has not yet considered

    result of check using material.

    Error > 5 % : COR < 0.95 or COR > 1.05

    Multi-percent deviations suggest

    wrong data input (e.g. beltinclination not exactly known, lever

    arms) and/or mechanical faults

    (misalignment, distorsions).

    Check does not consider Parameter WeightCorrection" D 02, so that check program willindicate same error quotient COR after check.

    Feed rate display for check weight:

    I D02C05

    C04=

    I = Feed rate in t/h

    C05 = Check Weight in kg

    C04 = Device Constant in kg/(t/h)

    D02 = Weight Correction

    0405

    VDM INTECONT PLUS

    Setting ProgramsBV-H2219 GB 30

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    >. CW 5.325 %COR 0.9915%

    >. CW 51.4%SET/ACT 0.9842%

  • 7/30/2019 BVH2219gb

    37/87

    Simulation Mode

    Simulation Mode lets you check all scale functionswithout material at the time of commissioning.During simulation, scale is cannot operate in normalmode.

    Gf Function distributor, Calibration functions,password (see Calibration Functions).

    TU Scroll Start Simulation into lower displayfield.

    fStart program.

    Display : Event message S7

    In upper line, = symbolflashes.

    Function can be cut off in the same way (STOP

    Simulation).

    Features:

    1. All operating functions can be performed.

    2. Feed rate actual value is set to nominal rate.

    3. Measured load measurement is active.

    4. All control inputs and outputs operate in normalfashion.

    Set Time

    Unlike the other programs, date and time can bechanged in Start and Stop states of scale and be readoff under SERVICE VALUES.

    Gf Function distributor, calibration functions,password (see Calibration Functions).

    TU Scroll Set Time into lower display field.

    f Call menu.

    NAbort at any time.

    0 3 Enter year, e.g. 03, month, day, hour,minute, and second.

    f Acknowledge every input.When seconds have beenacknowledged, new date is acquired.

    Complete date is displayed for some seconds.

    O Delete digit entered last.

    After power failure, time remains stored for min. 5days.

    0405

    INTECONT PLUS VDM

    Setting ProgramsBV-H2219 GB 31

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    38/87

    0405

    VDM INTECONT PLUS

    Setting ProgramsBV-H2219 GB 32

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    This page left intentionally blank

  • 7/30/2019 BVH2219gb

    39/87

    7. S e rv i ce V a lu e s

    The Service table includes detailed systeminformation. Call does not affect weighing functions.

    GTf Call SERVICE VALUESfunction and start.

    TU Move through service values.

    NReturn to normal displays.

    Displays:

    1. VMD 20600-00 2063 Version number2. HW = 1 Hardware version3. Opt.K: 0 (no option card)

    1 option card available)

    4. Date and time

    5. Relay outputs switching conditions

    I +: DO = 1 1 1 0 0 0 0 0

    1 = Contact closed

    0 = Contact openInputs 4-8 on option cardN = No option card

    6. Inputs switching conditions

    I+ : DI = 1 1 1 1 1 + 0

    1 = Contact closed0 = Contact open

    Inputs 4 + 5 on option cardN = No option card

    Inputs 6 + 7 are designed as Namur inputs(external input)

    + short-circuit; - cable breakage;

    1 = sensor covered; 0 = sensor free

    7. EL = 22 h

    Voltage ON-time

    Monitoring: Parameter K 01, Message S4

    8. ED = 19 h

    Scale On-time

    Condition : Totalization ON

    Monitoring : Parameter K 03, MessageS3

    9. aw = 30.988 %

    Load on load cells related to total of load cellrated capacities.If value exceeds 100%, load cells areoverloaded.

    From 110 % onward, Message H4:L/C Input > MAX is output.

    10 wz = 1.383257 mV/V

    Unnormalised output value of load cellamplifier (Gross)

    11. R_wz = 300 ohms

    Load cell resistance value

    0405

    INTECONT PLUS VDM

    Service ValuesBV-H2219 GB 33

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    O Z1 = 1500100 kg

    Opt..IND : 1

  • 7/30/2019 BVH2219gb

    40/87

    12. AO1 = 4.15 mA

    Analog output 1 output current

    13. AO2 = 10.00 mA

    Analog output 2 output current(on option card)

    14. ZE = 53

    Pulses output across pulse output for externaltotalizing counter, counted after commandReset Counter 1".

    15. ZO = 1

    Pulses still to be output.If value keeps exceeding zero, pulsefrequency is higher than 10 Hz.Increase weighting of smallest display digit ofCounter 1 (Parameter B 10).

    16. AI = 12.54 mA

    Analog input input current .

    17. CS = 10851

    Scale software check sum

    18. CS_b = 10851

    Check sum cyclically recomputed. If valueCS_b is unequal to CS, a serious fault isgiven. Contact the Schenck Service.

    19. Iun = 4876 kg/h

    Unlinearized feed rate

    0405

    VDM INTECONT PLUS

    Service ValuesBV-H2219 GB 34

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    41/87

    8. P a ra m et e r iz a ti o n

    General Information

    Parameters are variable characteristics or data used

    to match INTECONT to the application.

    Display units and formatLimit valuesNominal and calibration data, etc.

    Some parameters can be set in accordance with

    requirements (e.g. display formats), others have to be

    taken from Spec Sheet supplied.

    During parameter input, all functions are maintained.

    However, during operation, only parameters with no

    influence on measurement, e.g. display filters, should

    be changed.

    Default Values

    All parameters are preset with default values. These

    are proven suggestions and can normally used as

    defined.

    The default values can be loaded using sub-function

    Load Default Parameters.

    Identification

    The parameters are organised into function blocks A,

    B, ... and, within a block, described by

    namenumber 1, 2, 3 ..andvalue.

    Values differing from default are identified by a *

    before the block letter.

    There are two types of parameter:

    Selection parameters

    Let you select from various options, e.g. WARNING,

    ALARM.

    Numeric parameters

    Enter numeric value, e.g. nominal feed rate.

    Call Parameter Menu

    G Call function distributor.

    TUf Scroll PROGRAMMING intolower display field andacknowledge.

    TUfSelect ENTER PARAMETER

    function.

    Bf Enter password 07734.

    Display shows title of first parameter block.

    N Return to normal display.For apr. 2 min., Parametermenu can be recalled withoutpassword input.

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 35

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    Nominal Feed RateB02 1000.0 kg/h

    Dialog Behaviour

    Block: A

  • 7/30/2019 BVH2219gb

    42/87

    Select Parameters

    1. Block Letter

    TU Move through blocks A, B ... upand down.Block letter flashes.

    f Select block.Display shows parameterselected last.

    2. Parameter Number

    TU Move through parameternumbers within a block.Parameter number flashes.

    fMove through parameter

    numbers independent of block(UP only).

    NN Return to block titles.Return to normal mode.

    Enter Parameters

    P Prepare input.

    TU Selection parameter:value flashes.Scroll desired value into lowerdisplay field.

    46 Go to the left (4) or to the right(6); see HardwareConfiguration.

    B9 Numeric parameters:Feature - - - - - - - - - - - - - - - -Enter value using number keys.

    f Acknowledge input.Next parameter is displayed.

    O Delete digits.

    N Abort input.

    OFF key 0" is always active; ON key I" only ifparameter input is complete.

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 36

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    Nominal Feed RateB02 10000.0 kg/H

    Rated DataBlock: B

  • 7/30/2019 BVH2219gb

    43/87

    Hardware Configuration

    When parameterising the hardware, the sourcedetermines whether unit, channel and level must be

    indicated or not. The table below will assist you in

    configuring the hardware.

    Source Unit Channel Level

    FB

    OP

    v

    DI

    DO

    AI

    I+

    I+

    I+

    DI1-DI7

    DO1-DO8

    HI, LO

    HI, LO

    As you can see, with Fieldbus (FB), Operator

    Panel (OP), Speed (v) and Not Assigned () no

    additional input is required.

    Digital Inputs (DI) and Digital Outputs (DO) require

    unit, channel and level to be indicated.With Analog Input (AI), the unit is firmly set to I+.

    Sample:

    Parameter B06 START Source" determines from

    where the scale is started.

    Description Source

    B06 START Source OP

    Alternatives FB, DI

    On standard the scale is started from the INTECONT

    keyboard.

    Alternatively, fieldbus or digital input (DI) can be

    selected. If DI is the desired source, additionally

    indicate channel and level (see table above). The unit

    is firmly set to I+.

    4

    6

    Keys 4 (go to the left) and 6 (go to theright) let you shift between source,channel and level.

    Load Default Parameters

    Lets you load the default setting.Function is protected by password and YES/NO

    prompt.

    Attention!All changes to parameters and calibration valuesget lost.

    G Select PROGRAMMING function,call DEFAULT PARAMETERS.

    B1 YES = 1NO = 0

    f Acknowledge selection.

    Power Failure

    Parameters remain stored for an unlimited period of

    time.

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 37

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    44/87

    Parameter Overview

    This list applies to software: VDM 20600-00

    BLOCK A Scale Definitions

    01 Language * ENGLISH

    02 Units SI

    BLOCK B Rated Data

    01 Feed Rate Unit kg/h

    02 Nominal Feed Rate 0200.000 t/h

    03 START Source OP

    04 FMZ1 Unit - t05 FMZ 1 Pulse Dur. 0 ms

    06 FMZ 2 Unit - t

    07 FMZ 3 Unit - t

    BLOCK C Calibrating Data

    01 Calibration Time 30.0 s

    02 L/C Charac. Value 2.0000 mV/V

    03 L/C Rated Cap. 60.000 kg

    04 Device Constant 0.0400 kg/h

    05 Check Weight 1.000 kg

    BLOCK D Calibrat. Results

    01 Nominal Platf. Load 8.00 kg

    02 Span Correction 1.0000

    03 Total Tare 0.00 kg/h

    04 Basic Tare N 0.00 kg/h

    05 Tare Correction T 0.00 kg/h

    06 Material Corr. 1.00

    BLOCK E Analog Output

    01 Source AO 1 I

    02 Elevation AO 1 4.00 mA

    03 Limit Value AO 1 20.00 mA

    04 Source AO 2 Q

    05 Elevation AO 2 4.00 mA

    06 Limit Value AO 2 20.00 mA

    BLOCK F Limit Values

    01 Value for I-MIN 5.0 % Io02 Event Class I-MIN W1 (L 01)

    03 Value for I-MAX 120.0 % Io

    04 Event Class I MAX W1 (H 01)

    BLOCK G Filter Setting

    01 I Display 3.0 s

    02 I Analog Output 3.0 s

    03 Q Display 3.0 s

    04 L/C FILTER 1.0 s

    05 Afterfl. Time 5.0 s

    BLOCK H Additional device

    01 AUTO Zero Active NO

    02 Autom. Zero Limit 1.00 % Io

    03 Zero Set Limit 5.00 % Io

    04 Tare Corr. MAX W1 (C 05)

    05 ZDO Active NO

    06 ZDO Limit 1.00 % Io

    BLOCK I Batch Mode

    01 Batch Dribble FD 100.000 kg

    02 Batch End 0.000 kg

    03 Adaption fact. 0.5

    04 Batch Tolerance 100000.000 kg

    05 Out of Tolerance W1 (B 01)

    06 AUTO Print NO

    07 Batch Source OP

    BLOCK J Printer Setting

    01 Baud Rate 960002 Print Subtotal Error

    03 Print Page Length 72

    BLOCK K Maintenance Int.

    01 Maintenance Elec. 3000 h

    02 Event Maint. EL. W1 (S 04)

    03 Maint. Scale Run. 3000 h

    04 Event Maint. Run. W1 (S 03)

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 38

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    45/87

    BLOCK L Comm. Fieldbus

    01 Protocol Type NO02 Host timeout 10 s

    03 Comm.-Error Host IGNORE (S 09)

    04 Address 1

    05 Resolution 4096

    06 Word sequence I:std/L:std

    07 Physics RS485

    08 Baud Rate 9600

    09 Format Data 8-E-1

    10 FLOAT-format SIEMENS-KG

    11 Physics RS422

    12 Baud Rate 9600

    13 Format Data 8-E-1

    14 Address 16

    15 FLOAT-format IEEE

    16 Configuration FIXED-1

    17 Address 16

    18 Baud Rate 125K

    19 Configuration FIXED-1

    20 Byte sequence Low - High

    21 Word sequence I:std/L:std

    BLOCK M Events

    01 Power Failure A (E 01)02 Memory Error A (S 01)

    03 L/C Input A (C 01)

    04 No Release W1 (S 02)

    05 L/C Input MAX A (H 04)

    06 L/C

  • 7/30/2019 BVH2219gb

    46/87

    Block A : Scale Definitions

    A 01 Language

    Range: DEUTSCHENGLISH*AMERICAN ENG*FRANCAISESPANOLITALIANO

    Default: DEUTSCH

    Selection holds for all displays, event messages and

    parameters.

    * identical

    A 02 Units

    Range: SINON-SI

    Default: SI

    Lets you change over displays and parameter inputs

    from SI units to American units.

    American Unit SI Unit Conversion *

    lbtfinch

    kgtmcm

    1 lb = 0.453593 kg1 t = 0.907185 t = 2000 lb1 f = 0.3048 m1 inch = 2.54 cm

    *also applicable to compound units, e.g. kg/h

    Block B : Rated Data

    B 01 Feed Rate Unit

    Range: - - - - - - t/h- - - - . - t/h- - - . - - t/h- - . - - - t/h

    - - - - - - kg/h- - - - . - kg/h- - -. - - kg/h- -.- - - kg/h

    Default:- - - - - - kg/h

    Determines feed rate display format

    B 02 Nominal Feed Rate

    Range: 0.0001..230000.0 t/h Default:200.0 t/h

    Reference for limit values and service displays

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 40

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    47/87

    B 03 START Source

    Range: OPFBDI

    Default: OP

    To start/stop totalization, there is no single solution:

    OP : From INTECONT keyboard

    FB : Via fieldbus interface

    DI : Using digital input. Default value is DI3.You can also use any other free digitalinput. Digital input operatesedge-controlled, i.e. if scale fails afterAlarm, remove START signal and re-apply.

    Dialog function Keyboard Mode lets you change over

    from selected source to keyboard, and vice versa.

    Note

    G05 defines the totalizing counter tracking time.

    If Parameter O01 Release is set to - -,

    no release is required.

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 41

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    48/87

    B 04 FMZ1 Unit

    Range: - - - - - - - t- - - - - . - t- - - - . - - t- - - . - - - t- - - - - - t *10

    - - - - - t *100- - - - - - - kg- - - - - . - kg- - - - . - - kg- - - . - - - kg

    Default: - - - - - - - t

    B10 determines the display format for counter 1,

    batching values and pulse weighting for externalcounter. If no external counter is present, set

    Parameter B11 to 0.

    B 05 FMZ 1 Pulse Dur.

    Range: 0....1000 ms Default: 0 ms

    Length of external counter output pulse. Pulse

    weighting corresponds to the smallest display digit of

    counter 1 (Parameter B04).

    B05 < 10 ms : Pulse output is blocked.

    All pulses not yet output are

    deleted.

    Output frequency at nominal feed rate:

    PNENN= nominal feed rate in kg/h or t/hnZmin = smallest display digit of counter 1

    (B 04) in kg or t

    Select Zmin (B 04) so that f does not exceed 10 Hz.

    Furthermore, pulse duration B05 should be smaller

    than 1/f .

    B 06 FMZ 2 Unit

    As with B04; however, for counter 2

    B 07 FMZ 3 Unit

    As with B04; however, for counter 3

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 42

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    49/87

    Block C : Calibrating Data

    C 01 Calibration Time

    Range: 1...9999 s Default: 30 s

    Measuring time for taring and zero settings programs

    C 02 L/C Charac. Value

    Range: 0.01...9.9999 mV/V Default: 2 mV/V

    Load cell characteristic value (transmission factor)

    C 03 L/C Rated Cap.

    Range: 0.5000...220000.0 kg Default: 60 kg

    Total of load cells rated capacities

    C 04 Device Constant

    Range: 0.00100...1.0 kgh/t Default:0.04 kgh/t

    Unit: kg h/t = kg / (t/h)

    The device constant indicates the correlation of

    measured load and feed rate, i.e. load on load cell in

    kg / t/h.

    Q = Measured load on load cell in kg

    I = Feed rate in t/h

    GK determines calibration accuracy. For value, see

    technical Spec Sheet.

    C 06 Check Weight

    Range: 0.010...22 000.0 kg Default: 1 kg

    The check weight is used to check weighing systemusing calibration program CW: Weight Check.

    Enter weight actingon load cell through check weight.

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 43

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    GK = QI

    in kgt / h

  • 7/30/2019 BVH2219gb

    50/87

    Block D : Calibrat. Results

    D 01 Nom. Platform Load

    No input Default: 8000 kg

    Computed from rated data B 02 and C 04

    Nominal measured load serves as reference for limit

    values and zero setting programs.

    For computation, see DETAILS chapter.

    D 02 Weight Correction

    Range: 0.5000...2,0000 Default: 1,0000

    Proportionally influences feed rate I measurement

    I(corrected) = I(measured) D 02

    Function: Correct measuring system through

    check using material andcalibration program CW: Weight

    Check

    D 03 Total Tare

    No input Default: 0.00 kg/h

    Total tare = basic tare + tare correction

    = D04 + D05

    D 04 Basic Tare N

    No inputmax. 10000 kg/h

    Default: 0.00 kg/h

    Result of taring program

    D 05 Tare Correction T

    No inputmax. +- 1000 kg/h

    Default: 0.00 kg/h

    Result of manual or automatic zero setting.

    Every taring operation sets D 05 to 0.

    D 06 Material Corr.

    Range: 0.5000...2,0000 Default: 1

    Proportionally influences measurement of linearized

    feed rate I.

    I(corrected) = I(measured) D 06

    Function: Correct feed rate through check using

    material

    Attention!If you enter Parameters D 02 ... D 05 in manual, enterD 02 first.

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 44

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    51/87

    Block E : Analog Output

    E 01 Source AO 1

    Range: I (feed rate)Q (measured load)

    Default: I

    One of these values can be output in analog fashion.

    Filters: Parameters G 02, G 04

    E 02 Elevation AO 1

    Range: 0.00...20.00 mA Default: 4.00 mA

    Output current of 0% value I, or Q.

    E 03 Limit Value AO 1

    Range: 0.00...1000.00 mA Default: 20.00 mA

    Output current of 100% value I, or Q.

    X = I, Q Xnom = nominal value

    Note:

    1) Maximum output current is 20 mA.

    2) Minimum output current corresponds to elevation E02.

    3) In Stop state of scale, output for I is set to elevationvalue; for Q, measurement value is output.

    E 04 Source A02

    Range: I (feed rate)Q (measured load)

    Default: Q

    See Parameter E01

    E 05 Elevation A02

    Range: 0.00...20.0 mA Default: 4.00 mA

    See Parameter E02

    E 06 Limit Value A02

    Range: 0.00...1000.00 mA Default: 20.00mA

    See Parameter E03

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 45

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    i = ELEV + (END- ELEV)X

    Xnom

  • 7/30/2019 BVH2219gb

    52/87

    Block F : Limit Values

    F 01 Value for I MIN

    Range: -10...200.0 % Io Default: 5.0 % Io

    Related to nominal feed rate B 02

    If measurement value exceeds MIN limit, event

    message L1 is output.

    Monitoring starts 10 s after start-up.

    F 02 Event Class I MIN L1

    Range: WARNING 2WARNING 1IGNORE

    ALARM

    Default:WARNING 1

    F 03 Value for I MAX

    Range: -10...200.0 % Io Default: 120.0 %Io

    Related to nominal feed rate B 02

    If measurement value exceeds MAX limit, event

    message H1 is output.

    F 04 Event Class I MAX H1

    Range: WARNING 2WARNING 1IGNOREALARM

    Default:WARNING 1

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 46

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    53/87

    Block G : Filter Settings

    I = feed rate

    G 01 I Display

    Range: 0.0...600.0 s Default: 3.0 s

    Feed rate display

    G 02 I Analog Output

    Range: 0.0...600.0 s Default. 3.0 s

    Feed rate analog output

    G 03 Q Display

    Range: 0.0...600.0 s Default: 3.0 s

    Measured load display

    G 04 L/C Filter

    Range: 0.0...600.0s Default: 1.0 s

    Applies to all functions and displays depending on

    measured load

    Q = measured load

    G 05 Afterfl. Time

    Range: 0.0...2000.0 s Default: 3.0 s

    During specified time, totalization goes on after scale

    stop.

    All filters are of the first-order type(exponential), i.e. upon abruptchange of signal, approx. 2/3of full scale are reachedafter set time.

    Long times lead to a stablebut slowly refreshing display.

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 47

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    54/87

    Block H : Additional Device

    H 01 AUTO Zero Active

    Range: NOYES Default: NO

    Lets you select automatic zero setting.

    NO : No automatic zero setting

    YES : Automatic is running, if1. Measurement is cut off2. No other setting program is running3. No parameters are input.Start delay is 60s.

    Measuring time : Parameter C 01

    Monitorings: Parameters H 02...H04

    Display feature : 0 in upper display field

    H 02 Autom. Zero Limit

    Range: 0.00...10.00%Q Default: 1%Q

    Related to: Nom. Platform Load D01

    If mean value measured by automatic zero setting

    function falls below H 02 and H03 over time C01, zero

    point is corrected.

    Result: :Parameter D 05

    H 03 Zero Set Limit

    Range: 0.00...100.00 %Io Default: 5.00 %Io

    Bezug: Nom. Platf. Load D01

    Max. admissible amount of the total of all manual and

    zero setting operations.

    If limits are exceeded, correction value is not

    acquired.

    Monitoring : Parameter H 04, message C5

    H 04 Tare Corr. > MAX C5

    Range: WARNING 1WARNING 2ALARMIGNORE

    Default:WARNING 1

    Automatic zero setting result exceeds limit H 03.

    Value is not acquired.

    H 05 ZDO Active

    Range: NOYES Default: NO

    Active Zero Drop Out (see H 06).

    H 06 ZDO Limit

    Range: 0.0...10.00 %Io Default: 1.00 %Io

    Related to: Nominal Feed Rate B 02

    If Zero Drop Out is active and feed rate exceeds set

    limit, value is set to 0.

    No display feature.

    Conditions: Totalization ON or Afterfl. Time

    G 05.

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 48

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    55/87

    Block I : Batch Mode

    For detailed batching sequence, see DETAILS chapter.

    I 01 Batch Dribble FD

    Range: 0.00...220 000 kg Default: 100.000 kg

    If batch setpoint (I 01-I 02) is reached, dribble feed

    output (P08) is set.

    Signal can be used, e.g. to reduce prefeeder rate.

    I 02 Batch End

    Range: 0.00...220 000 kg Default: 0.000 kg

    If batch setpoint has reached pre-cut-off amount I 02,

    batching terminates and prefeeder stops.

    I 02 considers material afterflow, if any.

    I 03 Adaption Fact.

    Range: 0.0...1.0 Default: 0.5

    Pre-cut-off amounts I 01 and I 02 are adapted

    automatically so that the system better fits the

    situation upon next batch.

    The two values are adapted by value

    batch error * I 03".

    I 03 = 0 : no adaption

    I 03 = 1 : full adaption

    Intermediate values cause a filtered adaption which is

    preferable in plants with unprecise repeatability

    behaviour.

    I 04 Batch Tolerance

    Range: 0.0...2200000.0 kg Default:100000.000 kg

    Related to batch setpoint

    Admissible deviation from setpoint. Check takes place

    after completion of batch.

    I 05 Out of Tolerance B1

    Range: WARNING 1WARNING 2ALARMIGNORE

    Default:WARNING 1

    If limit value I 04 is exceeded, event message B1 is

    output .

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 49

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    56/87

    I 06 AUTO Print

    Range: NOYES

    Default: NO

    YES : Automatic printout after every completebatch

    NO: Batch report can be printed only usingcontrol menu.

    I 07 Batch Source

    Range: OPFB Default: OP

    OP : Enter batch and make-up setpoints fromINTECONT keyboard

    FB : Values are set via fieldbus.

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 50

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    06.03.03 16:20:16Batch Setpoint 200 kgBatch Actual Val. 205 kgCounter 1 31779 kgCounter 2 32 tBatch-Number 6

    Events B1 Out of Tolerance I05

  • 7/30/2019 BVH2219gb

    57/87

    Block J : Printer Settings

    J 01 Baud Rate

    Range: 2400480096001920038400

    Default: 9600

    Speed of transmission to printer

    J 02 Print Subtotal

    Range: ErrorYESNO

    Default: Error

    Error : Every event is printed automatically assoon as occurred

    YES : See above, but complete with totalizingcounter (FMZ) sub-totals

    NO : No printout

    Printing takes place in Normal and Batching modes.

    J 03 Print Page Length

    Range: 9...127 lines Default: 72 lines

    Page length for Quantity Report

    Line spacing is always 1/6 inch.

    Printer initializes upon change of parameter orpower-up.

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 51

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

    30.09.03 11:45:21 L1 W1 --> I < MIN

    30.09.03 11:59:01 L1 W1

  • 7/30/2019 BVH2219gb

    58/87

    Block K : Maintenance Int.

    K 01 Maintenance Elec.

    Range: 0...10000 h Default: 3000 hMessage: S4(K 02)

    Alerts you on maintenance work to be effected as a

    function of voltage ON-time.

    K 02 Event Maint. EL. S4

    Range: WARNING 1WARNING 2IGNORE

    Default:WARNING 1

    The total of power ON-times exceeds time K 01.

    If a time interval has elapsed, message S4 is output.

    K 03 Maint. Scale Run.

    Range: 0...10000 h Default: 3000 hMessage: S3(K 04)

    Alerts you on maintenance work to be effected as a

    function of scale run time.

    K 04 Event Maint. Run. S3

    Range: WARNING 1WARNING 2IGNORE

    Default:WARNING 1

    Total measuring times exceeds time K 03.

    If a time interval has elapsed, message S3 is output.

    0405

    VDM INTECONT PLUS

    ParameterizationBV-H2219 GB 52

    TechnischeRedaktion BVED

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

  • 7/30/2019 BVH2219gb

    59/87

    Block L : Comm. Fieldbus

    L 01 Protocol Type

    Range: NOMODBUS COMP.S5-BCC COMP.MODBUSPROFIBUS DPDEVICENET

    Default: NO

    Eligible protocol variants.Every protocol requires an optional interface card to

    be present.

    COMP identifies the compatible protocols.

    L 02 Host Timeout

    Range: 0...600s Default: 10s

    If timeout value exceeds zero, a message from host

    system is expected to arrive during set time.

    L 03 Comm. Error Host S9

    Range: IGNOREW1 (WARNING 1)W2 (WARNING 2)A (Alarm)

    Default: IGNORE

    If no message is received during the time set by

    Parameter L02, event message S9 Data Link Host isoutput.

    L 04 Address

    Range: 1...254 Default: 1

    Slave address for Modbus protocol

    L 05 Resolution

    Range: 1...32767 Default: 4096

    Resolution of data for nominal value in Modbus

    protocol (integer format).

    L 06 Word SequenceRange: I: std/L:std

    I: swp/L: stdI: std/L: swpI: swp/L: swp

    Default: I: std/L: std

    Determines the word sequence within a data double

    word in the Modbus protocol.

    I stands for IEEE-754 values (floating point values)

    L stands for 4-byte integer values

    std does not swap the word sequence; swp does.

    L 07 Physics

    Range: RS232RS 422RS 485

    Default: RS 485

    Sets interface physics for Modbus

    L 08 Baud Rate

    Range: 2400480096001920038400

    Default: 9600

    Modbus baud rate

    0405

    INTECONT PLUS VDM

    ParameterizationBV-H2219 GB 53

    Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.

    TechnischeRedaktion BVED

  • 7/30/2019 BVH2219gb

    60/87

    L 09 Format Data

    Range: 8-E-18-0-18-N-28-N-1

    Default: 8-E-1

    Modbus data format (data bits - parity bit - stop bits)

    L 10 FLOAT-format

    Range: SIEMENS-KGIEEE

    Default:SIEMENS-KG

    Determines representation of floating point values for

    S5 protocol

    L 11 Physics

    Range: RS 232RS 422

    Default: RS 422

    Sets interface physics for S5 protocol

    L 12 Baud Rate

    Range: 2400480096001920038400

    Default: 9600