INTECONT PLUS
Solids Flow Meter
Operating Manual
BV-H2219 GB
-
7/30/2019 BVH2219gb
2/87
Contacts, Copyright
Sales: Tel.: +49 (0)6151 32 - 10 28Email: [email protected]
Service: 24h Emergency hotline: +49 (0) 172 - 650 17 00 Discontinuous Weighing Technology+49 (0) 171 - 255 11 95 Continuous Weighing Technology
Email: [email protected]
Business Segments:
Heavy Duty Weighing & Feeding
Service Tel.: +49 (0) 61 51 32 - 26 23Service Fax: +49 (0) 61 51 32 - 32 70
E-Mail: [email protected]
Light Duty Weighing & Feeding
Service Tel.: +49 (0) 61 51 32 - 25 72Service Fax: +49 (0) 61 51 32 - 20 72
E-Mail: [email protected]
Vibrating Machines
Service Tel.: +49 (0) 61 51 32 - 10 75Service Fax: +49 (0) 61 51 32 - 30 96
E-Mail: [email protected]
Transport & Logistics
Service Tel.: +49 (0) 61 51 32 - 24 48Service Fax: +49 (0) 61 51 32 - 13 69E-Mail: [email protected]
Components & Spare Parts
Service Tel.: +49 (0) 61 51 32 - 17 58Service Fax: +49 (0) 61 51 32 - 36 32E-Mail: [email protected]
Copyright 2004SCHENCK PROCESS GmbH
Measuring and Process SystemsLandwehrstrasse 55, D-64293 Darmstadthttp://www.schenck-process.com
All rights reserved. Any reproduction of manual, regardless of method, without prior permission bySCHENCK PROCESS GmbH in writing, even by excerpt, is prohibited.
Subject to change without prior notice.
-
7/30/2019 BVH2219gb
3/87
Contents
1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Power ON 4
LEDs 4
Normal Displays 5
Operation in Normal Mode 5
Event Messages 6
Function Distributor 8
Display Check and Version Number 8
Keyboard Mode 9
START/STOP Feeder 9
EasyServe Active/Deactive 9
Batching Mode 10
Loading By Sight 13
Print Batch Report 13
Zero Setting 15
Read Parameters 17
3. Control Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5. Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6. Setting Programs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Function Distributor 27
Calibrating Functions 28
TW Tare 28
CW Weight Check 29
Simulation Mode 310405
INTECONT PLUS VDM
ContentsBV-H2219 GB I - 1
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
4/87
Set Time 31
7. Service Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8. Parameterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Select Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Enter Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Hardware Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Load Default Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Parameter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
9. Event Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
System Message S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Electrical System E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Calibration C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Maximum H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Minimum L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Material Flow (Batch) B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Signal Lamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
10. Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Test Plug 65
11. Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Start Sources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Batching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Data Flow Charts: Signal Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Base Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Option Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Printer Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
12. Replacement Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Replacing INTECONT PLUS FIP > INTECONT PLUS VEG . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 0405
VDM INTECONT PLUS
ContentsBV-H2219 GB I - 2
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
5/87
0405
INTECONT PLUS VDM
ContentsBV-H2219 GB I - 3
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
This manual applies to software version VDM 20600-00.
Edition : 0405
-
7/30/2019 BVH2219gb
6/87
0405
VDM INTECONT PLUS
ContentsBV-H2219 GB I - 4
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
This page left intentionally blank
-
7/30/2019 BVH2219gb
7/87
1. O ve rv ie w
On INTECONT:
INTECONT PLUS is designed as measuring and
evaluation system for
Belt WeighersSolids Flow MetersMass Flow MetersMass Flow FeedersWeighfeedersLoss-in-weight Feeders
The system is supplied in 3 variants:
1. Without option card (standard)
2. With option card VFE 610Vfor additional input/outputs and printer
3. With option card for fieldbusVSS021V : Modbus/S5VPB 020V: ProfibusVCB020V: DeviceNet
The present manual applies to solids flow meters with
controlled material prefeeder.
Task:
A Solids Flow Meter is designed for continuous
weighing of materials with free flowing or fluidizable
properties. Combined with a controlled material
prefeeder, preset material amounts can be batched.
For Further Reading:Fieldbus manual BVH2220
S5-RK512 (3964R) FH 458
Modbus (Comp) FH 525
Display:
5 x 7 - dot matrix with 6 mm character height
Upper display left : running messageright : totalized amount in kg/h or
t/h
Lower display left : event messagesright : selectable
flow rate, measured load,etc.
Display can be changed over to American units.
LEDs:
2 green and 3 red LEDs
Green LEDs : Ready
Red LEDs : Error or limit value messages
0405
INTECONT PLUS VDM
OverviewBV-H2219 GB 1
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
O Z1 = 362.5 kgE1 I = 1 0 0 0 kg/h
-
7/30/2019 BVH2219gb
8/87
Keyboard:
Flexible membranes with tactile touch
gB Start/stop measurement
TU Preselect lower displaySelect functions
i Reset counter
G FUNC Call function distributor andevent texts
O DEL Acknowledge event message,delete input
N ESC Abort function
f ENT Start function,acknowledge input
P DAT Prepare input, e.g. of setpoint
B9 Enter parameters
KL Enter sign and decimal point
Some Definitions:
I = Feed rate in kg/h or t/hMaterial amount per unit time
Z = Totalized amount in kg or t
Q = Measured loadLoad on load cells in kg
Measuring Principle:
Material is guided to measuring chute S free from
whirls.
Deflection force acts on load cell L/C whose output
voltage is proportional to flow rate.
INTECONT evaluates signal and computes flow rate
and totalized amount.
Measuring Technique:
n Precision AC voltage amplifier with continuous
correction of zero point and range.
n Highly resolving analog-to-digital converter.The integrated method is designed to efficientlysuppress mains voltage interferences.
n 16-bit microcontroller
n Unlimited storage of counter readings,configuration and calibration data.
0405
VDM INTECONT PLUS
OverviewBV-H2219 GB 2
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
9/87
The schematic below shows all inputs and outputs.
The sample mechanical equipment presents a systemequipped with crossed flexure strip.
S = Measuring chute
L/C = Load cell
M = Relay output for material prefeeder
F, G = Relay output for full feed/dribblefeed changeover
Z = External totalizing counter
A = Analog display for feed rate or
measured load
SERIAL = Serial interface for printer and host
computer
24 V = Power supply
ALARM = Relay output for ALARM
MIN = Relay output for MIN limit value
MAX = Relay output for MAX limit value
ACK = Acknowledge event messages
EXT INPUT = External interrupt input
ON = Relay output, scale started
START/STOP = Start and stop scale
Release = Release input
0405
INTECONT PLUS VDM
OverviewBV-H2219 GB 3
Transmissionto third partiesand reproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
O Z1 = 362.5 k gI = 1498 kg/h
-
7/30/2019 BVH2219gb
10/87
2. C on tr ol
Power ON
During power failure
all counter readings
counter pulses still to be output
preselected normal displays,
Service values, e.g. ON-time
are stored for an unlimited time.
The internal clock continues running for approx. 5
days.
After power-up, an automatic display and lamp test is
performed, followed by the display version number,
then by normal displays.
Message E1
reports power failure .
Message can be configured as ALARM or WARNING.
ALARM: Red LED X and symbol E1 flash.
Acknowledge message before startingscale.
WARNING: LEDX remains dark, symbol E1 doesnot flash.No acknowledgement required.
Start scale manually or automatically.
O Acknowledge event message.
LEDs
a (green) POWER OKlit if all power supplies are OK.
b (green) CPU OKlit if microprocessor is ready tooperate.
X (red) ALARMflashes if an Alarm is available.In addition, the event code is
shown in lower display line.
MIN (red) MIN LIMIT VALUElit if feed rate limit value isexceeded down.
MAX (red) MAX LIMIT VALUElit if feed rate limit value isexceeded up.
READY: The two green signal lamps light;no Alarm is available.
0405
VDM INTECONT PLUS
ControlBV-H2219 GB 4
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
Z1 = 2 5 0 0 kgE1 I = 0 kg/h
Z1 = 2 5 0 0 kgE1 I = 0 kg/h
-
7/30/2019 BVH2219gb
11/87
Normal Displays
Upper DisplayLeft : Running message and operating modes.
Rotating point indicates that totalizationand material prefeeder are active.
Right : Totalizing counter 1
Operating Modes
Lower Display
Left Event reported by alphanumeric code,e.g. E1 for power failure.
Right Selectable
TU Select display
Counter Z1 Z1 = 5000 kg
Counter Z2 Z2 = 6000 kgCounter Z3 Z3 = 1000 kgFeed rate I = 1000 kg/hFeed rate Ir = 50,00 % 1)Measured load Q = 10.000 kgMeasured load rel. Qr = 68,91% 2)Batch Zb, ZI, Zd, Nb, Zbn, Zdn 3)
1) related to nominal feed rate
2) related to nominal measured load
3) see Batching Mode
Display formats and units of Z1, Z2, Z3 and I can be
selected individually.
Operation in Normal Mode
g Start totalization.Condition : External Release signal
available (selectable).START_Source (B03) setto OP or Keyboard modeactive.
Feature : Rotating point in left fieldof upper display
B Stop totalization.Feature: points stands stillMeasured load continues being acquired.
i Reset totalizing counters.
1 Enter number of desired counter (1 or 2).FMZ No. : _Counter 3 cannot be reset. In case ofoverflow, counting resumes from 0.
fAcknowledge input.
N Delete faulty digits.
TU Select lower display(see Normal Displays).
O Acknowledge event message.
GCall further functions, e.g. Display Event,
Calibration.
N Exit function distributor.
0405
INTECONT PLUS VDM
ControlBV-H2219 GB 5
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
Z1 = 5 0 0 0 kgZ2 = 6 0 0 0 kg/h
-
7/30/2019 BVH2219gb
12/87
Event Messages
Definitions
All important scale functions are internally monitored.
Errors are reported by event message.
For troubleshooting details, see chapter Event
Messages.
Message E1 Power Failure
Message is output in left field of lower display in form
of a group letter (e.g. E) and a number (e.g. 1). In
addition, an explanatory text can be called up.
The events are organized into 4 classes. The
assignment of event to class can be selected using
relevant parameter.
n ALARM Display flashing and underscored.
In addition, red signal lampXflashes.
Totalization cuts off, scale is not
operable.
Start:
First remove cause of fault and
acknowledge message.
Acknowledgement:
If cause has not been removed
yet, flashing stops, underscoresare deleted, but message is still
available.
If fault is remedied after
acknowledgement, message
automatically effaces.
n WARNING 1 Display permanent and
underscored.
Totalization continues.
Acknowledgement:
If fault has not been remedied yet,
underscore is faded out.
n WARNING 2 Display permanent, not
underscored.
Acknowledgement:
Not required.
n IGNORE No monitoring of events, save
MIN/MAX messages and deviation
via contact outputs and signal
lamps.
If several events occur at the same time, the event
with the highest priority is displayed first.
Priority: Alarm, Warning 1, Warning 2.
Operation
O Acknowledge all available events ofclasses Alarm and Warning 1.If several events are available,acknowledge same one after the other.
To display event texts:
G Call function distributor.
TU Scroll Display Events into lower displayfield (normally not required).
f Select function.
0405
VDM INTECONT PLUS
ControlBV-H2219 GB 6
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
Z1 = 2 5 0 0 kgE1 I = 0 kg/h
-
7/30/2019 BVH2219gb
13/87
Display shows:
Name e.g. No Release
Code e.g. S2
and hint e.g. Parameter M04
of respective event.
The hint informs the service staff of the relevant
parameter. The consecutive number relates to the
priority sequence.
TU View several events.
N Return to normal displays.
List of Events
The list is sorted by display priority.
System Message S S1 Memory Error *
S2 No Release
S3 Maint. Scale Run
S4 Maintenance Int. Elec
S7 Simulation Active
S9 Data Link Host
Batching B B1 Out of Tolerance
B9 Linearization
Electrical System E E1 Power FailureE6 External Input
Calibration C C1 L/C Input*
C5 Tare Corr. > MAX
Maximum H H1 I >MAX
H4 L/C Input > MAX
Minimum L L1 I < MIN
L4 L/C Input
-
7/30/2019 BVH2219gb
14/87
Function Distributor
The function distributor lets you call further functions
and/or dialogs.
G Call function distributor.If no event is available, display shows thefunction selected last. If an event isavailable, the Display Events function isdisplayed.
f Start function.
N Return to normal displays and/orabort function.
TUMove through function distributor.
Display Events EDisplay CheckSTART/STOP FeederService ValuesSTART/STOP KEYB. MODESelect Batch BEasyServe active/deactiv>0< Zero SetProgrammingCalib.Functions SPrint FMZ
Read ParametersEnter Parameters SLoad Default Par. SPrint ParametersPrint Stat. Rep.
START/STOP SimulationTW: TareCW: Weight CheckSet Time
Programming and Calibrating Functions lead to
further menus you can move through using cursor
keys.
B = If batching mode is selected, additionalfunctions can be accessed in maindistributor.
Abort BatchDeselect BatchBatch NumberPrint BatchReload
S = Calibrating functions accessible after
password input.Prompt is output after call of function
E = Only if an event is available
With opposed functions, e.g. START/STOP, only the
one currently availabe can be reached.
Moving in function distributor does not limit any
scale-specific functions.
Display Check and Version Number
This function lets you check displays and signal
lamps.
G
TU
f
Call Display Check function.1. All display elements rhythmically
flash.2. Version number is displayed for
approx. 10 s.Test terminates automatically.
Example:
VMD : Solids Flow Meter 20600-00 : Version number
0405
VDM INTECONT PLUS
ControlBV-H2219 GB 8
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
FunctionDisplay Events
I N T E C O N T P L U SVDM 20600-00 2063
-
7/30/2019 BVH2219gb
15/87
Keyboard Mode
This function lets you shift the selected control source
for START/STOP to the INTECONT keyboard.
After deselection of Keyboard mode, the former
source is active again.
Upon changeover from external source (e.g. serial) to
keyboard, START/STOP status is maintained.
In reverse direction, the external signals are active.
GT Call function distributor.Select START Keyboard Mode orSTOP Keyboard Mode function.
Display feature:
You will know Keyboard mode by the square in the left
upper display field.
START/STOP Feeder
The START/STOP Feeder function lets you start and
stop material prefeeder.
In started state (ON), INTECONT controls prefeeder.
The normal Start/Stop commands cannot be used.In Stop state, material flow is interrupted and scale
can be tared, etc.
GT Call function distributor.Select Start Feeder or Stop Feederfunction.
f Start function.
EasyServe Active/Deactive
The EasyServe Active/Deactive functions let you
control your INTECONT using the EasyServe PC
service tool.
GT Call function distributor.Select EasyServe Active function
To set communication parameters, useBlock Q.
Note: Upon power failure, the current status isstored, i.e. EasyServe Active functionneeds not be re-called.
Connection to PC can also be made using a 9-pole
SUB-D connector on X4 (RS 232 only) or a Phoenix
connector on X5 (RS232, RS422 or RS485).
See also Wiring Diagram in chapter DETAILS.
0405
INTECONT PLUS VDM
ControlBV-H2219 GB 9
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
16/87
Batching Mode
Batching mode is used to feed a defined amount of
material. When batch setpoint is reached, batching
operation is complete.
0 Start batch, open prefeeder.
1 Abort batch at any timeand
2 resume.
3 Change over to dribble feed by reducing prefeederoutput.
4 Cut off prefeeder.
5 Batch setpoint is reached.
Additional Displays
Upper display: If batching mode is selected, totals
sign G.
is displayed left of running
message.
The square indicating Keyboard
mode is omitted.
Lower display:
TU Use cursor keys to scroll 3additional values into display field.
1. Zb = Batch setpoint
2. ZI = Batch actual value
(amount already
discharged)
3. Zd = Batch residual value
(amount still to be
discharged)
Zd = Zb-ZI
4. Nb = Consecutive batchnumber.
To set start value, use
Batch Number
function.
Before start of a batch, ZI and Zd indicate the
amounts fed out during previous batch.
Batching mode deselected (Deselect Batch
function), displays are disabled but can be used again
upon next selection.
Display format corresponds to the format of Counter
1.
Select Batching Mode
Selection of Batching mode enables batching,
however, no batch is started yet.
Condition: Scale OFF
G Call function distributor.
TU Scroll Select Batch function into displayfield.
f Select function.
System prompts for input of batch setpoint.
If batch is selected from external PC, setpoint input is
omitted.
0405
VDM INTECONT PLUS
ControlBV-H2219 GB 10
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
EO Z1 = 2 5 0 0 kgZ2 = 4 0 0 kg
-
7/30/2019 BVH2219gb
17/87
Enter Setpoint
Prompt for setpoint input is output automatically uponselection or can be started in manual when batch is
complete (scale OFF).
If Batching mode is deselected or a batch is running,
no input is possible.
If batch setpoint is preset via fieldbus (Parameter I07
Batch Source=FB), no input is possible either. This
also applies to input of batch number and reload
setpoint.
P Prepare setpoint input.
19 Enter setpoint.Max. 9 digits including decimal point.The unit is that of Counter 1.
f Acknowledge input.
N Abort input; old setpoint is maintained.
O Delete faulty digits.
Start and Abort
g Start batch, process starts.Display ZI : moves from 0 towards
setpointDisplay Zd : moves from setpoint
towards 0
B Abort batch.
Batching continues upon next Startcommand.
Deselect Batch
Lets you deselect Batching mode, i.e. mode is removedfrom available functions.
Totals sign disappears from upper display, batchingvalues ZI, Zd, Zb and Nb are not longer available but
remain stored.
Conditions: Batch complete, or aborted using
Abort Batch function, scale OFF.
GTf
Call function distributor.Select Deselect Batch function.
Acknowledge.
The Select Batch function lets you reactivate
batching mode.
The old ZI, Zd , Zb and Nb values can be viewed
again.
0405
INTECONT PLUS VDM
ControlBV-H2219 GB 11
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
EO SetpointZb = - - - - - - kg
-
7/30/2019 BVH2219gb
18/87
Abort Batch
Lets you abort a running batch, i.e. batchingimmediately stops.
Batching mode remains selected.
New batch starts upon next start command, old batch
is not resumed.
The Reload function lets you complete old batch.
GT Call function distributor and select AbortBatch function.
f Acknowledge.
You can also abort batch using contact O02.
Reloading
Lets you add a specified amount to a complete batch.
Conditions : Running batch complete, scale
OFF. No batch report.
Display ZI : Batch actual value increments from
value achieved.
Display Zd : Batch residual value keeps valueachieved.
Display Zbn : Make-up setpoint
Display Zdn : Batch residual value of make-up
amount.
Zdn = Zbn - make-up amount
reloaded
All displays can be scrolled into lower display field.
Zdn and Zbn are available only until start of next
batch.
GT Call function distributor.Select Reload function.
f Acknowledge function.System prompts for input of reloadsetpoint in kg or t.The unit is that of counter 1.
P Change setpoint Zbn before start ofreloading.
gB Start or abort reloading.
If reloaded batch is complete, next Start command
starts a normal batch.
To repeat reloading, re-call function.The Abort Batch function lets you also abort
reloading.
Batch Number Nb
Enter batch number. Number increments by 1 upon
start of every new batch.
Number is printed in batch report and can be viewed
in lower display.
Reloading operations belong to previous batch and
are not counted.
GT Call function distributor.Select Batch Number function.
f Acknowledge.Prompt for input ofNb = - is output.
f Acknowledge input.
N Abort input.Old number is maintained.
You can also change current number during batching.
0405
VDM INTECONT PLUS
ControlBV-H2219 GB 12
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
19/87
Loading By Sight
Batch report can be printed only if a batch is complete
(setpoint reached).
If you wish to batch an amount not previously
determined and print the result, follow these steps:
1. Call Select Batch function.
2. Select very high batch setpoint, e.g. 999999999 kg.
3. Scroll batch actual value ZI into lower display field.
4. Start scale.
5. If amount ZI is reached, stop scale.
6. Call Stop Batch function.
7. Start printing (see Print Batch).
The Reload function can be performed only before
print command.
For next batch, follow steps 4...7.
Print Batch Report
The printing functions require an option card to be
present.
Print Batch
Start of printout disables the Reload function for the
batch in question.
Function can be called only in Batching mode.
Printing can be started:
1. Manually via function distributor2. Automatically, after each complete batch
(Parameter I 06).
GT Call function distributor.Select Print Batch function.
f Start function.
N Abort printing.
Batch Report
07.07.03 : Date and timeBatch setpoint: Preset batch amountBatch act. value: Amount batchedCounter 1 : Totalizing counter 1Counter 2 : Totalizing counter 2Batch number : Consecutive number NB of scaleEvents : Events available during printout
0405
INTECONT PLUS VDM
ControlBV-H2219 GB 13
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
07.07.03 11:45:10
Batch setpoint 0.150 t
Batch act.value 0.150 t
Counter 1 0.806 t
Counter 2 806.47 kg
Batch number 40
Events
E1 Power Failure M01
-
7/30/2019 BVH2219gb
20/87
Print Counter Readings (FMZ)
Identical with batch report; however, the title isQuantity Report.
Batch number, setpoint and actual value are printed
only if Batching mode is selected.
To call:
1) Select Print FMZ function.Unlike Print Batch, report canalso be printed duringbatching.
2) Automatically upon each event printout(Parameter J 02 = YES)
Print Parameters
Lets you print out parameter list complete with current
values.
Parameter values varying from default settings are
cross-marked (*).
As Appendix, a list of possible events and current
hardware assignment is printed.
GT Call function distributor.Select Print Parameters function.
f Start function.
N Abort printing at any time.
Print Events
Parameter J 02 lets you decide whether event
messages are to be printed or not.
Eligible settings :
1. No printout (NO)
2. Print events (Error)
3. Print events and counter readings (YES)(see Batching)
L1 : Event code
W1 : Message class, e.g. WARNING 1
> : Event has occurred
-
7/30/2019 BVH2219gb
21/87
Voltage ON-time
Total voltage ON-time
Scale ON-Time
Total ON-time of measurement and INTECONT
Events after last status report
Number and type of events since last report printout.
If report is printed for the first time, counting starts
from power-On.
Counters 1, 2, 3
Totalizing counters 1-3
Zero Setting
The zero setting program lets you acquire the
measuring systems zero point error over a settable
time.
The acquired value is used to correct the current
measuring result during operation.
Effects:
1. During zero setting, totalizing counters stop.
2. Analog value is set to elevation value.
3. Events continue being monitored.
Conditions:
1. No material flow
2. Scale turned off(prefeeder, if present, closes).
Follow these steps:
G Call function distributor.
TU Scroll >0< (zero set) into lower displayfield.
f Start function.
N Abort function at any time.
0405
INTECONT PLUS VDM
ControlBV-H2219 GB 15
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
STATUS REPORT INTECONT PLUS
03.06.03 13:37:12
Software : VMD 20600-00 2063Hardware version : 1Option card version : 1Station address : 1- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Mode OP : NOMode Simulation : NOScale ON : NO
Alarm : NOVoltage ON-time : 35 hScale ON-time : 23 hCounter 1 : 5635 kgCounter 2 : 6 tCounter 3 : 6 t-----------------------------------------------------------
Events after last status report
2 * S02 No Release
-
7/30/2019 BVH2219gb
22/87
Program Running:
Upper display : Residual run time in % of total run
time
Lower display : Zero point error related to nominal
measured load
N Abort program at any time.
Program Complete:
Upper display: Deviation of zero point from
previous zero setting operation
in % of nominal measured load
dev = + : error increased
dev = - : error decreased
Lower display: Mean value of total zero point in %
of nominal measured load
f Accept Tarkor result and enter intoParameter D 05.
N Reject result, i.e. scale not tared.
Special Messages:
1. OFF INTECONT is still ON
2. ABORTED Zero setting result has not beaccepted
3. VALUE TOO BIG Zero setting result hasexceeded specified limits(Parameter H03).Result is rejected.
0405
VDM INTECONT PLUS
ControlBV-H2219 GB 16
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
0o Dev. 2.45%Tarkor 3.50 %
0o >0< 70 %Tarkor 1.12 %
-
7/30/2019 BVH2219gb
23/87
Read Parameters
Parameters are defined as variable characteristics or
data used to match the INTECONT to the application.
Parameter input is protected by password.
The Read Parameters function lets you view all
parameters without jeopardizing the operating safety.
The parameters are organized into function blocks A ,
B... and consecutively numbered within a block.
GT
f
Scroll Programming function intodisplay field and acknowledge.
Tf Select Read Parameters sub-function.
Display shows title of first parameter block.
TU Move through parameter blocks A, B...
fT Move through parameters within a block.
N Return to blocks.
N Return to normal displays.
For details, see Enter Parameters.
0405
INTECONT PLUS VDM
ControlBV-H2219 GB 17
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
Nominal Feed RateB02 1000.0 kg/h
Scale DefinitionsBlock: A
-
7/30/2019 BVH2219gb
24/87
This page left intentionally blank
0405
VDM INTECONT PLUS
ControlBV-H2219 GB 18
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
25/87
3. C o nt r ol O v er v ie w
Status Displays (Upper Display Field)
In normal mode, totalizing counter Z1 is displayed.
Point rotates Scale (totalization) started
Control Keys:
gB Start/stop totalization (if selected)
U
T
SCROLL Select lower display and functions.1. Counters Z2, Z3 4. Measured load Q2. Feed rate I 6. Batch displays Zb, ZI, Zd, Nb, Zbn, Zdn3. Feed rate Ir in %
iRESET Reset totalizing counter.
1. Enter number of desired counter (1 or 2). Counter 3 cannot be reset.2. Acknowledge input with ENTER key, or3. Abort with ESCAPE key, or4. Delete faulty input with DELETE key
G FUNCTION Call function distributor and event messages.1. Select desired function using SCROLL keys.
If an event is available, Display Events function is already selected.2. Activate function with ENTER key.3. Pass through available event messages with SCROLL keys.4. Return to normal display with ESCAPE key
0405
INTECONT PLUS VDM
Control OverviewBV-H2219 GB 19
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
O Z1 = 362.5 kg-- I = 100 k g/h
-
7/30/2019 BVH2219gb
26/87
0405
VDM INTECONT PLUS
Control OverviewBV-H2219 GB 20
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
O DELETE Acknowledge event message, delete input.
N ESCAPE Abort function, return to normal displays.
f ENTER Acknowledge input, e.g. parameter.Start function, e.g. Display Events (see FUNCTION).
P DATA Prepare input, e.g. parameters
Lower display field shows event message, if any, e.g. symbol S2 = No Release.
List of Events
sorted by display priority.
System Messages S1 Memory Error *
S2 No Release
S3 Maint. Scale Run
S4 Maintenance Int. Elec
S7 Simulation Active
S9 Data Link Host
Batching B1 Out of Tolerance
B9 Linearization
Electrical System E1 Power Failure
E6 External Input
Calibration C1 L/C Input *
C5 Tare Corr. > MAX
Maximum H1 I >MAX
H4 L/C Input > MAX
Minimum L1 I < MIN
L7 WZ Eingang
-
7/30/2019 BVH2219gb
27/87
4. T e ch n ic a l D a ta
n Panel-mounting unit: VEG 20600/20610Front panel :96 x 288 mm
Panel cut-outs : 88 x 282, wall thicknessmax. 10 mm
Mounting depth : min. 225 mm(including 50 mm forconnectors)
Protected to : IP 20, front to IP 65
Material : plastic grey to RAL 7022
Display : fluorescent, 2 lines of 20characters, 6 mm high
Keyboard : f lexible membranes withtactile touch
Signal lamps : LEDs, 2 x green, 3 x red
Power supply : 24 V(DC) +50 % -25%,max. 1 A,no fuse, pole-reversalprotective circuit
Ext. power supply : 90...264V/ 50HZ...60HZ
n Surface-mounting unit: with panel mounting unitVEG 20...
n Wall-mounting housing
Measuringsystems : width x height x depth
410x330x236mm
Feedingsystems : width x height x depth
500x600x300mm
Protected to : IP 65
Material : steel sheet, 1.5 mm, greyVoltage supply : 90...264V/50Hz...60Hz
Extension : Feed unit controller
n Environment
Temperature : -25 C ... +45 C,tested to -40C
Humidity : Class F (DIN 40 040) *
Interferenceimmunity : to IEC 801
Interference
suppression : to VDE 871, EN 55 011
Housing safety : to IEC 348
EC recommen-
dations : CE label
* Tropical version (class R) upon request
n Storage temperature
-40 C ... +60 C
n Connectors
Plug/screw connectors (Phoenix Combicon),non-confusible
n Control outputs
Number : 8 N/O relay contacts
Base board : 3
Option card : 5
Load : max. 230 V(AC)8 A resistive load, 1 Ainductive
If error message CPU Not OK is output, all contacts
open.0405
INTECONT PLUS VDM
Technical DataBV-H2219 GB 21
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
P = 100.00 kg/hI = 0 kg/h
-
7/30/2019 BVH2219gb
28/87
n Control inputs
Number : 5Base card : 3
Option card : 2
Type : 24 V(DC) +/-30 %, 5 mA,galvanically isolated
n Control inputs (NAMUR)
Number : 2
Type : NAMUR (DIN 19234),short-circuit and cablebreakage monitoring
n Analog output
Number : 2
Base card : 1
Option card : 1
Current : raise ...20 mA impressed
Raise : 0...
-
7/30/2019 BVH2219gb
29/87
n Load cell connection
Voltage supply : +/- 6 V AC (+/-3 %)(apr. 66 Hz),short-circuit-proof
Measuring cycle : 100ms
Resolution : 24 Bit
Load : R (load cell) = min. 80 ohms
Cable length : max. 30 % voltage drop,max. 500 m
Measuring range : -20mV....+50mVwith VLW:-1.6mV...min. 32mV
n Serial interface for service PC
Number : 1
Type : RS232; RS422 or RS 485max. 19200 baud
Data format : 8 data bits, 1 stop bit, oddparity changeable to even orno
Isolation : galvanically non-isolated
Connectors : Phoenix MSTB, contactspacing 3.5 mm, max. 1.5mm2 or 9-pole D-Sub HD20
0405
INTECONT PLUS VDM
Technical DataBV-H2219 GB 23
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
30/87
0405
VDM INTECONT PLUS
Technical DataBV-H2219 GB 24
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
This page left intentionally blank
-
7/30/2019 BVH2219gb
31/87
5. C ha ra ct er is ti cs
n Power Failure
Scale data, calibration values, counter readings and
pulses pending remain stored after power failure for
an unlimited period of time. The internal clock
continues running for approx. 5 days.
n Dialog Languagefor error messages, operation, and serviceprograms.
Eligible : DEUTSCHENGLISHFRANCAISESPANOLITALIANO
n Units (selectable)
SI units : kg, kg/ht , t/h
m , cmNON-SI units : lb , lb/h
t , t/hf , inch
(see Parameter Shortlist)
n Start/Stop Totalizing Counter
Select using Parameter B03.
n Release, Emergency Stop
Functions are realized using a digital input O01.
n Displays
Upper display : Totalizing counter 1
Lower display: Totalizing counters 2...3Feed rate absolute IFeed rate relative IrMeasured load absoluteMeasured load relativeBatch data
Select lower display using cursor keys.
n Signal Lamps (top down)
VOLTAGE OK (green)PROCESSOR OK (green)ALARM (red)MIN (red) feed rate MIN limitMAX (red) feed rate MAX limit
n Event Messages
Events and faults are displayed in form of analphanumeric code.Call clear text of events via keyboard.Events are organized into Alarms, and Warningswith and without acknowledgement. Alarms stopscale, warnings dont.
All alarms are additionally reported via relayoutputs.
n Operating Philosophy
Operator prompting through multi-level menus.Important configuration and calibration functionsare protected by password.
0405
INTECONT PLUS VDM
CharacteristicsBV-H2219 GB 25
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
32/87
n Zero Setting
Zero setting is performed by an automatic program.No material is required.Program can be started
1. manually via keyboard2. automatically with closed prefeeder
Max. admissible zero setting amount is monitored.
n Taring
Designed to zero the basic tare load, the taringprogram on principle has the same function as thezero setting program. However, tare elevation is notmonitored, and the call is protected by password.
n Zero Drop Out
Suppresses totalization upon measurementsaround zero point, so that counter stops with smallfeed rates.Deselect function if not desired.
n Display Filters
can be defined individually for feed rate andmeasured load.
n Maintenance Hints
through display of event s
1. Voltage ON-time
2. Scale ON-time
n Adaptions
The electrical system needs not be redesigned noradapted.
n Calibration
Calibration as such is not required. All you have todo is enter some constructional data of load cells,speed transducer, belt inclination, etc. INTECONTuses these data to compute all requisite displaynormalisations.Check, or recalibration, canbe effectedin twoways:
a) Using material
Enter check result into INTECONT, andmeasurement value will be corrected.
b) Using check weight
A special check program lets you checknormalizations, and correct them if technicaldata or not exactly known. In later operation,program can also be used to show technicalmodifications.
n Digital Inputs
Number Name Default
O03
O01B03O02O02
DI Ackn. Events
ReleaseSTART SourceDI Stop BatchDI Ext. Event
DI1
DI2-(OP)--
n Digital Outputs
Nummer Name Default
P04P05P01
P02P03P07P08P06
DO I-MINDO I-MAXDO ALARM
DO Prefeeder ONDO Feeder ONFull FeedDribble FeedDO Batch Active
D01DO2D03
D06D05---
0405
VDM INTECONT PLUS
CharacteristicsBV-H2219 GB 26
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
33/87
6. S e tt i n g P r og r am s
Function Distributor
The function distributor lets you call further functions
and/or dialogs.
G Call function distributor.If an event is available, Display Eventsis displayed; if no event has occurred,display shows function selected last.
f Start function.
N Return to normal displays, or abortfunction.
TU Move through function distributor.
Display Events EDisplay CheckSTART/STOP FeederService ValuesSTART/STOP Keyb. ModeSelect Batch BEasyServe active/deactiv>0< Zero SetProgramming
Calib.Functions SPrint FMZ
Read ParametersEnter Parameters SLoad Default Par. SPrint ParametersPrint Stat. Rep
START/STOP SimulationTareCW: Weigh CheckSet Time
Programming and Calibration functions lead to furthermenus you can move through using cursor keys.
B = If Batching mode is selected, additionalfunctions can be accessed in maindistributor.
Abort BatchDeselect BatchBatch NumberPrint BatchReload
S = Calibrating functions protected bypassword. Prompt for password input isoutput after call of function.
E = If an event is available.
With opposed functions, e.g. START/STOP, only the
one currently accessible can be called.
Moving through function distributor has no effect on
weighing functions.
0405
INTECONT PLUS VDM
Setting ProgramsBV-H2219 GB 27
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
F u nc t i o nD i s p l a y E v e n t s
-
7/30/2019 BVH2219gb
34/87
Calibrating Functions
Menu item Calibration Functions lets you access 3
functions:
1. TW Tare
2. CW: Weight Check
2. Set Time
All functions are protected from unauthorized use bypassword.The operating sequence is the same for all programs.
GCall function distributor.
TUf Scroll CALIBRATIONFUNCTIONS into lower displayfield and acknowledge.
. . . . . .f Enter password 07734.
Display shows one of the setting programs, e.g. TW:Tare.
f Start setting program.
N Return to normal displays.For apr. 2 min., Calibrationmenu can be recalled without
password input.
TW Tare
The taring program acquires zero point error of
complete measuring system over a settable time
(Parameter C 01, default = 30 s).
INTECONT uses this value to correct measuring
result during operation.
In contrast to zero setting program, zero setting range
is not monitored nor limited.
Taring program deletes the zero setting result.
Effects: 1. During taring, no totalizationtakes place.
2. Analog output is set toelevation value.
3. Events continue beingmonitored.
Conditions: 1. No material flow.2. Scale cut off
(prefeeder closed, if present).
Follow these steps:
Gf Function distributor, Calibration functions,password (see Calibration Functions).
TU Scroll TW: Tare function into lowerdisplay field.
f Start function.
N Abort at any time
0405
VDM INTECONT PLUS
Setting ProgramsBV-H2219 GB 28
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
CALIBRATION FUNCTIONSTW: Tare
-
7/30/2019 BVH2219gb
35/87
Program running:
Upper display: Residual run time in % of total run
time
Lower display: Continuously meaned tare in % of
nominal measured load
Program complete:
Upper display : Deviation of tare value from
previous taring operation
in % of nominal measured load
dev = +: tare increased
dev = - : tare decreased
Lower display : Mean value of total tare
in % of nominal measured load
f Accept taring result and enter value intoParameter D 04.Tare correction (D05) is set to zero.
N Reject result, i.e. scale not tared.
Special Messages:
1. STOP if INTECONT is still started
2. ABORTED if taring result is not acquiredyet
CW Weight Check
This program lets you check the INTECONT
measuring range.
Load measuring system with a known check weight
and acquire load cell load mean value over a certain
time.
INTECONT compares result with specified setpoint
and displays value.
No automatic correction takes place.
Effects:
1. During run time, no totalization takes place.
2. Analog output is set to elevation value.3. Events continue being monitored.
Conditions:
1. Taring or zero setting performed
2. Effective check weight entered into Parameter C 05
3. Check weight applied in provided point
4. Scale cut off
Sequence:
Gf Function distributor, Calibration function,password (see Calibration Functions)
TU Scroll CW: Weight Check into lowerdisplay field.
f Start program.
N Abort at any time
0405
INTECONT PLUS VDM
Setting ProgramsBV-H2219 GB 29
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
>0< Dev. 2.45 %Tare 3.50%
>.
>0< TW: 9 0. 2 %T a r e 5 2. 3 5
-
7/30/2019 BVH2219gb
36/87
Program running
Upper display : Residual run time in % of total run
time
Lower display : Continuously meaned SET/ACT
measuring result
Program complete
Upper display : ACTUAL measured load in kg
Lower display : Mean value COR of SET/ACT over
total run time
fN Exit program.Since result is not acquired automatically,
the two keys are equivalent.
Special hints:
1. STOP if INTECONT is still ON
2. ABORTED after exit of program
* Lets you check scale zero point without check weightDisplay format: xxxxxxx,yy kg
Evaluating result:
Error < 1 % : COR = 0.99...1.01Scale OK, no further action
required.
Error < 5 % : COR = 0.95...1.05
Enter KOR value into Parameter D
02 .
This makes good sense only if
parameter has not yet considered
result of check using material.
Error > 5 % : COR < 0.95 or COR > 1.05
Multi-percent deviations suggest
wrong data input (e.g. beltinclination not exactly known, lever
arms) and/or mechanical faults
(misalignment, distorsions).
Check does not consider Parameter WeightCorrection" D 02, so that check program willindicate same error quotient COR after check.
Feed rate display for check weight:
I D02C05
C04=
I = Feed rate in t/h
C05 = Check Weight in kg
C04 = Device Constant in kg/(t/h)
D02 = Weight Correction
0405
VDM INTECONT PLUS
Setting ProgramsBV-H2219 GB 30
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
>. CW 5.325 %COR 0.9915%
>. CW 51.4%SET/ACT 0.9842%
-
7/30/2019 BVH2219gb
37/87
Simulation Mode
Simulation Mode lets you check all scale functionswithout material at the time of commissioning.During simulation, scale is cannot operate in normalmode.
Gf Function distributor, Calibration functions,password (see Calibration Functions).
TU Scroll Start Simulation into lower displayfield.
fStart program.
Display : Event message S7
In upper line, = symbolflashes.
Function can be cut off in the same way (STOP
Simulation).
Features:
1. All operating functions can be performed.
2. Feed rate actual value is set to nominal rate.
3. Measured load measurement is active.
4. All control inputs and outputs operate in normalfashion.
Set Time
Unlike the other programs, date and time can bechanged in Start and Stop states of scale and be readoff under SERVICE VALUES.
Gf Function distributor, calibration functions,password (see Calibration Functions).
TU Scroll Set Time into lower display field.
f Call menu.
NAbort at any time.
0 3 Enter year, e.g. 03, month, day, hour,minute, and second.
f Acknowledge every input.When seconds have beenacknowledged, new date is acquired.
Complete date is displayed for some seconds.
O Delete digit entered last.
After power failure, time remains stored for min. 5days.
0405
INTECONT PLUS VDM
Setting ProgramsBV-H2219 GB 31
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
38/87
0405
VDM INTECONT PLUS
Setting ProgramsBV-H2219 GB 32
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
This page left intentionally blank
-
7/30/2019 BVH2219gb
39/87
7. S e rv i ce V a lu e s
The Service table includes detailed systeminformation. Call does not affect weighing functions.
GTf Call SERVICE VALUESfunction and start.
TU Move through service values.
NReturn to normal displays.
Displays:
1. VMD 20600-00 2063 Version number2. HW = 1 Hardware version3. Opt.K: 0 (no option card)
1 option card available)
4. Date and time
5. Relay outputs switching conditions
I +: DO = 1 1 1 0 0 0 0 0
1 = Contact closed
0 = Contact openInputs 4-8 on option cardN = No option card
6. Inputs switching conditions
I+ : DI = 1 1 1 1 1 + 0
1 = Contact closed0 = Contact open
Inputs 4 + 5 on option cardN = No option card
Inputs 6 + 7 are designed as Namur inputs(external input)
+ short-circuit; - cable breakage;
1 = sensor covered; 0 = sensor free
7. EL = 22 h
Voltage ON-time
Monitoring: Parameter K 01, Message S4
8. ED = 19 h
Scale On-time
Condition : Totalization ON
Monitoring : Parameter K 03, MessageS3
9. aw = 30.988 %
Load on load cells related to total of load cellrated capacities.If value exceeds 100%, load cells areoverloaded.
From 110 % onward, Message H4:L/C Input > MAX is output.
10 wz = 1.383257 mV/V
Unnormalised output value of load cellamplifier (Gross)
11. R_wz = 300 ohms
Load cell resistance value
0405
INTECONT PLUS VDM
Service ValuesBV-H2219 GB 33
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
O Z1 = 1500100 kg
Opt..IND : 1
-
7/30/2019 BVH2219gb
40/87
12. AO1 = 4.15 mA
Analog output 1 output current
13. AO2 = 10.00 mA
Analog output 2 output current(on option card)
14. ZE = 53
Pulses output across pulse output for externaltotalizing counter, counted after commandReset Counter 1".
15. ZO = 1
Pulses still to be output.If value keeps exceeding zero, pulsefrequency is higher than 10 Hz.Increase weighting of smallest display digit ofCounter 1 (Parameter B 10).
16. AI = 12.54 mA
Analog input input current .
17. CS = 10851
Scale software check sum
18. CS_b = 10851
Check sum cyclically recomputed. If valueCS_b is unequal to CS, a serious fault isgiven. Contact the Schenck Service.
19. Iun = 4876 kg/h
Unlinearized feed rate
0405
VDM INTECONT PLUS
Service ValuesBV-H2219 GB 34
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
41/87
8. P a ra m et e r iz a ti o n
General Information
Parameters are variable characteristics or data used
to match INTECONT to the application.
Display units and formatLimit valuesNominal and calibration data, etc.
Some parameters can be set in accordance with
requirements (e.g. display formats), others have to be
taken from Spec Sheet supplied.
During parameter input, all functions are maintained.
However, during operation, only parameters with no
influence on measurement, e.g. display filters, should
be changed.
Default Values
All parameters are preset with default values. These
are proven suggestions and can normally used as
defined.
The default values can be loaded using sub-function
Load Default Parameters.
Identification
The parameters are organised into function blocks A,
B, ... and, within a block, described by
namenumber 1, 2, 3 ..andvalue.
Values differing from default are identified by a *
before the block letter.
There are two types of parameter:
Selection parameters
Let you select from various options, e.g. WARNING,
ALARM.
Numeric parameters
Enter numeric value, e.g. nominal feed rate.
Call Parameter Menu
G Call function distributor.
TUf Scroll PROGRAMMING intolower display field andacknowledge.
TUfSelect ENTER PARAMETER
function.
Bf Enter password 07734.
Display shows title of first parameter block.
N Return to normal display.For apr. 2 min., Parametermenu can be recalled withoutpassword input.
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 35
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
Nominal Feed RateB02 1000.0 kg/h
Dialog Behaviour
Block: A
-
7/30/2019 BVH2219gb
42/87
Select Parameters
1. Block Letter
TU Move through blocks A, B ... upand down.Block letter flashes.
f Select block.Display shows parameterselected last.
2. Parameter Number
TU Move through parameternumbers within a block.Parameter number flashes.
fMove through parameter
numbers independent of block(UP only).
NN Return to block titles.Return to normal mode.
Enter Parameters
P Prepare input.
TU Selection parameter:value flashes.Scroll desired value into lowerdisplay field.
46 Go to the left (4) or to the right(6); see HardwareConfiguration.
B9 Numeric parameters:Feature - - - - - - - - - - - - - - - -Enter value using number keys.
f Acknowledge input.Next parameter is displayed.
O Delete digits.
N Abort input.
OFF key 0" is always active; ON key I" only ifparameter input is complete.
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 36
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
Nominal Feed RateB02 10000.0 kg/H
Rated DataBlock: B
-
7/30/2019 BVH2219gb
43/87
Hardware Configuration
When parameterising the hardware, the sourcedetermines whether unit, channel and level must be
indicated or not. The table below will assist you in
configuring the hardware.
Source Unit Channel Level
FB
OP
v
DI
DO
AI
I+
I+
I+
DI1-DI7
DO1-DO8
HI, LO
HI, LO
As you can see, with Fieldbus (FB), Operator
Panel (OP), Speed (v) and Not Assigned () no
additional input is required.
Digital Inputs (DI) and Digital Outputs (DO) require
unit, channel and level to be indicated.With Analog Input (AI), the unit is firmly set to I+.
Sample:
Parameter B06 START Source" determines from
where the scale is started.
Description Source
B06 START Source OP
Alternatives FB, DI
On standard the scale is started from the INTECONT
keyboard.
Alternatively, fieldbus or digital input (DI) can be
selected. If DI is the desired source, additionally
indicate channel and level (see table above). The unit
is firmly set to I+.
4
6
Keys 4 (go to the left) and 6 (go to theright) let you shift between source,channel and level.
Load Default Parameters
Lets you load the default setting.Function is protected by password and YES/NO
prompt.
Attention!All changes to parameters and calibration valuesget lost.
G Select PROGRAMMING function,call DEFAULT PARAMETERS.
B1 YES = 1NO = 0
f Acknowledge selection.
Power Failure
Parameters remain stored for an unlimited period of
time.
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 37
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
44/87
Parameter Overview
This list applies to software: VDM 20600-00
BLOCK A Scale Definitions
01 Language * ENGLISH
02 Units SI
BLOCK B Rated Data
01 Feed Rate Unit kg/h
02 Nominal Feed Rate 0200.000 t/h
03 START Source OP
04 FMZ1 Unit - t05 FMZ 1 Pulse Dur. 0 ms
06 FMZ 2 Unit - t
07 FMZ 3 Unit - t
BLOCK C Calibrating Data
01 Calibration Time 30.0 s
02 L/C Charac. Value 2.0000 mV/V
03 L/C Rated Cap. 60.000 kg
04 Device Constant 0.0400 kg/h
05 Check Weight 1.000 kg
BLOCK D Calibrat. Results
01 Nominal Platf. Load 8.00 kg
02 Span Correction 1.0000
03 Total Tare 0.00 kg/h
04 Basic Tare N 0.00 kg/h
05 Tare Correction T 0.00 kg/h
06 Material Corr. 1.00
BLOCK E Analog Output
01 Source AO 1 I
02 Elevation AO 1 4.00 mA
03 Limit Value AO 1 20.00 mA
04 Source AO 2 Q
05 Elevation AO 2 4.00 mA
06 Limit Value AO 2 20.00 mA
BLOCK F Limit Values
01 Value for I-MIN 5.0 % Io02 Event Class I-MIN W1 (L 01)
03 Value for I-MAX 120.0 % Io
04 Event Class I MAX W1 (H 01)
BLOCK G Filter Setting
01 I Display 3.0 s
02 I Analog Output 3.0 s
03 Q Display 3.0 s
04 L/C FILTER 1.0 s
05 Afterfl. Time 5.0 s
BLOCK H Additional device
01 AUTO Zero Active NO
02 Autom. Zero Limit 1.00 % Io
03 Zero Set Limit 5.00 % Io
04 Tare Corr. MAX W1 (C 05)
05 ZDO Active NO
06 ZDO Limit 1.00 % Io
BLOCK I Batch Mode
01 Batch Dribble FD 100.000 kg
02 Batch End 0.000 kg
03 Adaption fact. 0.5
04 Batch Tolerance 100000.000 kg
05 Out of Tolerance W1 (B 01)
06 AUTO Print NO
07 Batch Source OP
BLOCK J Printer Setting
01 Baud Rate 960002 Print Subtotal Error
03 Print Page Length 72
BLOCK K Maintenance Int.
01 Maintenance Elec. 3000 h
02 Event Maint. EL. W1 (S 04)
03 Maint. Scale Run. 3000 h
04 Event Maint. Run. W1 (S 03)
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 38
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
45/87
BLOCK L Comm. Fieldbus
01 Protocol Type NO02 Host timeout 10 s
03 Comm.-Error Host IGNORE (S 09)
04 Address 1
05 Resolution 4096
06 Word sequence I:std/L:std
07 Physics RS485
08 Baud Rate 9600
09 Format Data 8-E-1
10 FLOAT-format SIEMENS-KG
11 Physics RS422
12 Baud Rate 9600
13 Format Data 8-E-1
14 Address 16
15 FLOAT-format IEEE
16 Configuration FIXED-1
17 Address 16
18 Baud Rate 125K
19 Configuration FIXED-1
20 Byte sequence Low - High
21 Word sequence I:std/L:std
BLOCK M Events
01 Power Failure A (E 01)02 Memory Error A (S 01)
03 L/C Input A (C 01)
04 No Release W1 (S 02)
05 L/C Input MAX A (H 04)
06 L/C
-
7/30/2019 BVH2219gb
46/87
Block A : Scale Definitions
A 01 Language
Range: DEUTSCHENGLISH*AMERICAN ENG*FRANCAISESPANOLITALIANO
Default: DEUTSCH
Selection holds for all displays, event messages and
parameters.
* identical
A 02 Units
Range: SINON-SI
Default: SI
Lets you change over displays and parameter inputs
from SI units to American units.
American Unit SI Unit Conversion *
lbtfinch
kgtmcm
1 lb = 0.453593 kg1 t = 0.907185 t = 2000 lb1 f = 0.3048 m1 inch = 2.54 cm
*also applicable to compound units, e.g. kg/h
Block B : Rated Data
B 01 Feed Rate Unit
Range: - - - - - - t/h- - - - . - t/h- - - . - - t/h- - . - - - t/h
- - - - - - kg/h- - - - . - kg/h- - -. - - kg/h- -.- - - kg/h
Default:- - - - - - kg/h
Determines feed rate display format
B 02 Nominal Feed Rate
Range: 0.0001..230000.0 t/h Default:200.0 t/h
Reference for limit values and service displays
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 40
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
47/87
B 03 START Source
Range: OPFBDI
Default: OP
To start/stop totalization, there is no single solution:
OP : From INTECONT keyboard
FB : Via fieldbus interface
DI : Using digital input. Default value is DI3.You can also use any other free digitalinput. Digital input operatesedge-controlled, i.e. if scale fails afterAlarm, remove START signal and re-apply.
Dialog function Keyboard Mode lets you change over
from selected source to keyboard, and vice versa.
Note
G05 defines the totalizing counter tracking time.
If Parameter O01 Release is set to - -,
no release is required.
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 41
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
48/87
B 04 FMZ1 Unit
Range: - - - - - - - t- - - - - . - t- - - - . - - t- - - . - - - t- - - - - - t *10
- - - - - t *100- - - - - - - kg- - - - - . - kg- - - - . - - kg- - - . - - - kg
Default: - - - - - - - t
B10 determines the display format for counter 1,
batching values and pulse weighting for externalcounter. If no external counter is present, set
Parameter B11 to 0.
B 05 FMZ 1 Pulse Dur.
Range: 0....1000 ms Default: 0 ms
Length of external counter output pulse. Pulse
weighting corresponds to the smallest display digit of
counter 1 (Parameter B04).
B05 < 10 ms : Pulse output is blocked.
All pulses not yet output are
deleted.
Output frequency at nominal feed rate:
PNENN= nominal feed rate in kg/h or t/hnZmin = smallest display digit of counter 1
(B 04) in kg or t
Select Zmin (B 04) so that f does not exceed 10 Hz.
Furthermore, pulse duration B05 should be smaller
than 1/f .
B 06 FMZ 2 Unit
As with B04; however, for counter 2
B 07 FMZ 3 Unit
As with B04; however, for counter 3
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 42
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
49/87
Block C : Calibrating Data
C 01 Calibration Time
Range: 1...9999 s Default: 30 s
Measuring time for taring and zero settings programs
C 02 L/C Charac. Value
Range: 0.01...9.9999 mV/V Default: 2 mV/V
Load cell characteristic value (transmission factor)
C 03 L/C Rated Cap.
Range: 0.5000...220000.0 kg Default: 60 kg
Total of load cells rated capacities
C 04 Device Constant
Range: 0.00100...1.0 kgh/t Default:0.04 kgh/t
Unit: kg h/t = kg / (t/h)
The device constant indicates the correlation of
measured load and feed rate, i.e. load on load cell in
kg / t/h.
Q = Measured load on load cell in kg
I = Feed rate in t/h
GK determines calibration accuracy. For value, see
technical Spec Sheet.
C 06 Check Weight
Range: 0.010...22 000.0 kg Default: 1 kg
The check weight is used to check weighing systemusing calibration program CW: Weight Check.
Enter weight actingon load cell through check weight.
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 43
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
GK = QI
in kgt / h
-
7/30/2019 BVH2219gb
50/87
Block D : Calibrat. Results
D 01 Nom. Platform Load
No input Default: 8000 kg
Computed from rated data B 02 and C 04
Nominal measured load serves as reference for limit
values and zero setting programs.
For computation, see DETAILS chapter.
D 02 Weight Correction
Range: 0.5000...2,0000 Default: 1,0000
Proportionally influences feed rate I measurement
I(corrected) = I(measured) D 02
Function: Correct measuring system through
check using material andcalibration program CW: Weight
Check
D 03 Total Tare
No input Default: 0.00 kg/h
Total tare = basic tare + tare correction
= D04 + D05
D 04 Basic Tare N
No inputmax. 10000 kg/h
Default: 0.00 kg/h
Result of taring program
D 05 Tare Correction T
No inputmax. +- 1000 kg/h
Default: 0.00 kg/h
Result of manual or automatic zero setting.
Every taring operation sets D 05 to 0.
D 06 Material Corr.
Range: 0.5000...2,0000 Default: 1
Proportionally influences measurement of linearized
feed rate I.
I(corrected) = I(measured) D 06
Function: Correct feed rate through check using
material
Attention!If you enter Parameters D 02 ... D 05 in manual, enterD 02 first.
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 44
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
51/87
Block E : Analog Output
E 01 Source AO 1
Range: I (feed rate)Q (measured load)
Default: I
One of these values can be output in analog fashion.
Filters: Parameters G 02, G 04
E 02 Elevation AO 1
Range: 0.00...20.00 mA Default: 4.00 mA
Output current of 0% value I, or Q.
E 03 Limit Value AO 1
Range: 0.00...1000.00 mA Default: 20.00 mA
Output current of 100% value I, or Q.
X = I, Q Xnom = nominal value
Note:
1) Maximum output current is 20 mA.
2) Minimum output current corresponds to elevation E02.
3) In Stop state of scale, output for I is set to elevationvalue; for Q, measurement value is output.
E 04 Source A02
Range: I (feed rate)Q (measured load)
Default: Q
See Parameter E01
E 05 Elevation A02
Range: 0.00...20.0 mA Default: 4.00 mA
See Parameter E02
E 06 Limit Value A02
Range: 0.00...1000.00 mA Default: 20.00mA
See Parameter E03
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 45
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
i = ELEV + (END- ELEV)X
Xnom
-
7/30/2019 BVH2219gb
52/87
Block F : Limit Values
F 01 Value for I MIN
Range: -10...200.0 % Io Default: 5.0 % Io
Related to nominal feed rate B 02
If measurement value exceeds MIN limit, event
message L1 is output.
Monitoring starts 10 s after start-up.
F 02 Event Class I MIN L1
Range: WARNING 2WARNING 1IGNORE
ALARM
Default:WARNING 1
F 03 Value for I MAX
Range: -10...200.0 % Io Default: 120.0 %Io
Related to nominal feed rate B 02
If measurement value exceeds MAX limit, event
message H1 is output.
F 04 Event Class I MAX H1
Range: WARNING 2WARNING 1IGNOREALARM
Default:WARNING 1
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 46
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
53/87
Block G : Filter Settings
I = feed rate
G 01 I Display
Range: 0.0...600.0 s Default: 3.0 s
Feed rate display
G 02 I Analog Output
Range: 0.0...600.0 s Default. 3.0 s
Feed rate analog output
G 03 Q Display
Range: 0.0...600.0 s Default: 3.0 s
Measured load display
G 04 L/C Filter
Range: 0.0...600.0s Default: 1.0 s
Applies to all functions and displays depending on
measured load
Q = measured load
G 05 Afterfl. Time
Range: 0.0...2000.0 s Default: 3.0 s
During specified time, totalization goes on after scale
stop.
All filters are of the first-order type(exponential), i.e. upon abruptchange of signal, approx. 2/3of full scale are reachedafter set time.
Long times lead to a stablebut slowly refreshing display.
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 47
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
54/87
Block H : Additional Device
H 01 AUTO Zero Active
Range: NOYES Default: NO
Lets you select automatic zero setting.
NO : No automatic zero setting
YES : Automatic is running, if1. Measurement is cut off2. No other setting program is running3. No parameters are input.Start delay is 60s.
Measuring time : Parameter C 01
Monitorings: Parameters H 02...H04
Display feature : 0 in upper display field
H 02 Autom. Zero Limit
Range: 0.00...10.00%Q Default: 1%Q
Related to: Nom. Platform Load D01
If mean value measured by automatic zero setting
function falls below H 02 and H03 over time C01, zero
point is corrected.
Result: :Parameter D 05
H 03 Zero Set Limit
Range: 0.00...100.00 %Io Default: 5.00 %Io
Bezug: Nom. Platf. Load D01
Max. admissible amount of the total of all manual and
zero setting operations.
If limits are exceeded, correction value is not
acquired.
Monitoring : Parameter H 04, message C5
H 04 Tare Corr. > MAX C5
Range: WARNING 1WARNING 2ALARMIGNORE
Default:WARNING 1
Automatic zero setting result exceeds limit H 03.
Value is not acquired.
H 05 ZDO Active
Range: NOYES Default: NO
Active Zero Drop Out (see H 06).
H 06 ZDO Limit
Range: 0.0...10.00 %Io Default: 1.00 %Io
Related to: Nominal Feed Rate B 02
If Zero Drop Out is active and feed rate exceeds set
limit, value is set to 0.
No display feature.
Conditions: Totalization ON or Afterfl. Time
G 05.
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 48
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
55/87
Block I : Batch Mode
For detailed batching sequence, see DETAILS chapter.
I 01 Batch Dribble FD
Range: 0.00...220 000 kg Default: 100.000 kg
If batch setpoint (I 01-I 02) is reached, dribble feed
output (P08) is set.
Signal can be used, e.g. to reduce prefeeder rate.
I 02 Batch End
Range: 0.00...220 000 kg Default: 0.000 kg
If batch setpoint has reached pre-cut-off amount I 02,
batching terminates and prefeeder stops.
I 02 considers material afterflow, if any.
I 03 Adaption Fact.
Range: 0.0...1.0 Default: 0.5
Pre-cut-off amounts I 01 and I 02 are adapted
automatically so that the system better fits the
situation upon next batch.
The two values are adapted by value
batch error * I 03".
I 03 = 0 : no adaption
I 03 = 1 : full adaption
Intermediate values cause a filtered adaption which is
preferable in plants with unprecise repeatability
behaviour.
I 04 Batch Tolerance
Range: 0.0...2200000.0 kg Default:100000.000 kg
Related to batch setpoint
Admissible deviation from setpoint. Check takes place
after completion of batch.
I 05 Out of Tolerance B1
Range: WARNING 1WARNING 2ALARMIGNORE
Default:WARNING 1
If limit value I 04 is exceeded, event message B1 is
output .
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 49
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
56/87
I 06 AUTO Print
Range: NOYES
Default: NO
YES : Automatic printout after every completebatch
NO: Batch report can be printed only usingcontrol menu.
I 07 Batch Source
Range: OPFB Default: OP
OP : Enter batch and make-up setpoints fromINTECONT keyboard
FB : Values are set via fieldbus.
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 50
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
06.03.03 16:20:16Batch Setpoint 200 kgBatch Actual Val. 205 kgCounter 1 31779 kgCounter 2 32 tBatch-Number 6
Events B1 Out of Tolerance I05
-
7/30/2019 BVH2219gb
57/87
Block J : Printer Settings
J 01 Baud Rate
Range: 2400480096001920038400
Default: 9600
Speed of transmission to printer
J 02 Print Subtotal
Range: ErrorYESNO
Default: Error
Error : Every event is printed automatically assoon as occurred
YES : See above, but complete with totalizingcounter (FMZ) sub-totals
NO : No printout
Printing takes place in Normal and Batching modes.
J 03 Print Page Length
Range: 9...127 lines Default: 72 lines
Page length for Quantity Report
Line spacing is always 1/6 inch.
Printer initializes upon change of parameter orpower-up.
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 51
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
30.09.03 11:45:21 L1 W1 --> I < MIN
30.09.03 11:59:01 L1 W1
-
7/30/2019 BVH2219gb
58/87
Block K : Maintenance Int.
K 01 Maintenance Elec.
Range: 0...10000 h Default: 3000 hMessage: S4(K 02)
Alerts you on maintenance work to be effected as a
function of voltage ON-time.
K 02 Event Maint. EL. S4
Range: WARNING 1WARNING 2IGNORE
Default:WARNING 1
The total of power ON-times exceeds time K 01.
If a time interval has elapsed, message S4 is output.
K 03 Maint. Scale Run.
Range: 0...10000 h Default: 3000 hMessage: S3(K 04)
Alerts you on maintenance work to be effected as a
function of scale run time.
K 04 Event Maint. Run. S3
Range: WARNING 1WARNING 2IGNORE
Default:WARNING 1
Total measuring times exceeds time K 03.
If a time interval has elapsed, message S3 is output.
0405
VDM INTECONT PLUS
ParameterizationBV-H2219 GB 52
TechnischeRedaktion BVED
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
-
7/30/2019 BVH2219gb
59/87
Block L : Comm. Fieldbus
L 01 Protocol Type
Range: NOMODBUS COMP.S5-BCC COMP.MODBUSPROFIBUS DPDEVICENET
Default: NO
Eligible protocol variants.Every protocol requires an optional interface card to
be present.
COMP identifies the compatible protocols.
L 02 Host Timeout
Range: 0...600s Default: 10s
If timeout value exceeds zero, a message from host
system is expected to arrive during set time.
L 03 Comm. Error Host S9
Range: IGNOREW1 (WARNING 1)W2 (WARNING 2)A (Alarm)
Default: IGNORE
If no message is received during the time set by
Parameter L02, event message S9 Data Link Host isoutput.
L 04 Address
Range: 1...254 Default: 1
Slave address for Modbus protocol
L 05 Resolution
Range: 1...32767 Default: 4096
Resolution of data for nominal value in Modbus
protocol (integer format).
L 06 Word SequenceRange: I: std/L:std
I: swp/L: stdI: std/L: swpI: swp/L: swp
Default: I: std/L: std
Determines the word sequence within a data double
word in the Modbus protocol.
I stands for IEEE-754 values (floating point values)
L stands for 4-byte integer values
std does not swap the word sequence; swp does.
L 07 Physics
Range: RS232RS 422RS 485
Default: RS 485
Sets interface physics for Modbus
L 08 Baud Rate
Range: 2400480096001920038400
Default: 9600
Modbus baud rate
0405
INTECONT PLUS VDM
ParameterizationBV-H2219 GB 53
Transmissionto thirdparties andreproductionof this documentation are not permitted.SCHENCK PROCESS GmbH reserves allrights of ownership and copyrights.
TechnischeRedaktion BVED
-
7/30/2019 BVH2219gb
60/87
L 09 Format Data
Range: 8-E-18-0-18-N-28-N-1
Default: 8-E-1
Modbus data format (data bits - parity bit - stop bits)
L 10 FLOAT-format
Range: SIEMENS-KGIEEE
Default:SIEMENS-KG
Determines representation of floating point values for
S5 protocol
L 11 Physics
Range: RS 232RS 422
Default: RS 422
Sets interface physics for S5 protocol
L 12 Baud Rate
Range: 2400480096001920038400
Default: 9600