Busway Power Distribution - DLE ELECTRIC SUPPLY - …dlelectricsupply.com/files/ETBH308.pdf ·  ·...

5
Busway Power Distribution BD® Plug-In (225 - -1600 Ampere) SELECTION 225-1600 Amperes Cable Tap Box End® Catalog Number List Prices Center® Catalog Number List Price $ End Closure Catalog Number List Price $ Hangers® Catalog Number List Price $ Aluminum 3 Phase, 3 Wire EBA302 EBA304 EBA306 EBA308 EBA310 EBA312 1190. 1430. 2110. 2130. 2170. 2190. CBA302 CBA304 CBA306 CBA308 CBA310 CBA312 2200. 2680. 3640. 4290. 4610. 5490. ECP6 ECP6 ECP10 ECP10 ECA10 ECA10 123. 125. 129. BDH10 BDH12 SO. 52. 3 Phase, 4 Wire Full Capacity Neutral EBA4024 EBA4044 EBA4064 EBA4084 EBA4104 EBA4124 1310. 1640. 2410, 2430. 2460. 2490. CBA4024 CBA4044 CBA4064 CBA4084 CBA4104 CBA4124 2190. 2510. 3350. 3700. 4700. 5550. ECP6 ECP6 ECP10 ECA8 ECA10 ECA10 123. 125. 126. 129. BDH10 BDH12 BDH12 50. 52. 52. Copper 3 Phase, 3 Wire ETB302 ETB304 ETB306 ETB308 ETB310 ETB313 ETB316 1520. 1830. 2690. 2720. 2740. 2720. 2780. CTB302 CTB304 CTB306 CTB308 CTB310 CTB313 CTB316 2220. 2850. 3640. 4760. 5040. 7410. 7790. ECP6 ECP6 ECP6 ECP10 ECP10 ECA10 ECA10 123. 123. 125. 129. BDH10 BDH10 BDH10 BDH12 50. 50. SO. 52. 3 Phase, 4 Wire Full Capacity Neutral ETB4024 ETB4044 ETB4064 ETB4084 ETB4104 1200. 2050. 3000. 3150. 3190. CTB4024 CTB4044 CTB4064 CTB4084 CTB4104 2590. 3690. 4310. 5740. 6500. ECP6 ECP6 ECP6 ECA8 ECA8 123. 123. 130. BOH10 BDH10 BDH12 BDH12 Rod-Hanger Adaptor Packaged 10 per carton (optional) UJ100 52. 52. - - 10. Fusible Feed-In Switch® Rating Volts 240 AC or 250 DC 600 AC Amperes 400 600 400 600 3 Phase, 3 Wire Catalog Number® FTS3042 FTS3062 FTS3046 FTS3066 List Price $ 4100. 6070. 4310. 6770. 3 Phase, 4 Wire Catalog Number® FTS4042 FTS4062 FTS4046 FTS4066 List Price $ 4720. 6980. 4950. 7780. ©Includes busway stub. Total length added to run is 2' for 225A and 400A aluminum or 225A-600A copper; 3' for all others. Box is designed to connect to offset bus-bar ends. When it is to be connected to straight bus-bar ends, adaptor will be furnished upon request. ©Must be factory-assembled to busway. Complete device includes 10' busway. For aluminum catalog number, change "ABD" to "CBA" for copper change "BDP" to "CTB". ®Two hangers included free of charge with each busway section, elbow, tee and cross. ®The FTS is designed to connect to the offset bus bar ends. Arrangements contrary to this must be specified. ©When ordering the fusible feed-in switch, add to the catalog number "-C" for use with copper and "-A" for use with aluminum busway. D = Warehouse Stock Discount Schedule M Siemens Electrical Products SPEEDFAX 2000

Transcript of Busway Power Distribution - DLE ELECTRIC SUPPLY - …dlelectricsupply.com/files/ETBH308.pdf ·  ·...

Page 1: Busway Power Distribution - DLE ELECTRIC SUPPLY - …dlelectricsupply.com/files/ETBH308.pdf ·  · 2016-02-29Busway Power Distribution ... Rod-Hanger Adaptor Packaged 10 per carton

Busway Power Distribution

BD® Plug-In (225 - -1600 Ampere)SELECTION

225-1600 AmperesCable Tap Box

End®CatalogNumber

ListPrices

Center®CatalogNumber

ListPrice $

End Closure

CatalogNumber

ListPrice $

Hangers®

CatalogNumber

ListPrice $

Aluminum3 Phase, 3 Wire

EBA302

EBA304

EBA306

EBA308

EBA310

EBA312

1190.

1430.

2110.

2130.

2170.

2190.

CBA302

CBA304

CBA306

CBA308

CBA310

CBA312

2200.

2680.

3640.

4290.

4610.

5490.

ECP6

ECP6

ECP10

ECP10

ECA10

ECA10

123.

125.

129.

BDH10

BDH12

SO.

52.

3 Phase, 4 Wire — Full Capacity Neutral

EBA4024

EBA4044

EBA4064

EBA4084

EBA4104

EBA4124

1310.

1640.

2410,

2430.

2460.

2490.

CBA4024

CBA4044

CBA4064

CBA4084

CBA4104

CBA4124

2190.

2510.

3350.

3700.

4700.

5550.

ECP6

ECP6

ECP10

ECA8

ECA10

ECA10

123.

125.

126.

129.

BDH10

BDH12

BDH12

50.

52.

52.

Copper3 Phase, 3 Wire

ETB302

ETB304

ETB306

ETB308

ETB310

ETB313

ETB316

1520.

1830.

2690.

2720.

2740.

2720.

2780.

CTB302

CTB304

CTB306

CTB308

CTB310

CTB313

CTB316

2220.

2850.

3640.

4760.

5040.

7410.

7790.

ECP6

ECP6

ECP6

ECP10

ECP10

ECA10

ECA10

123.

123.

125.

129.

BDH10

BDH10

BDH10

BDH12

50.

50.

SO.

52.

3 Phase, 4 Wire — Full Capacity Neutral

ETB4024

ETB4044

ETB4064

ETB4084

ETB4104

1200.

2050.

3000.

3150.

3190.

CTB4024

CTB4044

CTB4064

CTB4084

CTB4104

2590.

3690.

4310.

5740.

6500.

ECP6

ECP6

ECP6

ECA8

ECA8

123.

123.

130.

BOH10

BDH10

BDH12

BDH12

Rod-Hanger Adaptor Packaged 10 per carton (optional) UJ100

52.

52.

-

-

10.

Fusible Feed-In Switch®Rating

Volts

240 AC or250 DC

600 AC

Amperes

400600

400600

3 Phase, 3 Wire

CatalogNumber®

FTS3042FTS3062

FTS3046FTS3066

List Price $

4100.6070.

4310.6770.

3 Phase, 4 Wire

CatalogNumber®

FTS4042FTS4062

FTS4046FTS4066

List Price $

4720.6980.

4950.7780.

©Includes busway stub. Total length added to run is 2'for 225A and 400A aluminum or 225A-600A copper;3' for all others. Box is designed to connect to offsetbus-bar ends. When it is to be connected to straightbus-bar ends, adaptor will be furnished upon request.

©Must be factory-assembled to busway. Completedevice includes 10' busway. For aluminum catalognumber, change "ABD" to "CBA" for copper change"BDP" to "CTB".

®Two hangers included free of charge with eachbusway section, elbow, tee and cross.

®The FTS is designed to connect to the offset busbar ends. Arrangements contrary to this mustbe specified.

©When ordering the fusible feed-in switch, add to thecatalog number "-C" for use with copper and "-A" foruse with aluminum busway.

D = Warehouse Stock

Discount Schedule M Siemens Electrical Products SPEEDFAX 2000

Page 2: Busway Power Distribution - DLE ELECTRIC SUPPLY - …dlelectricsupply.com/files/ETBH308.pdf ·  · 2016-02-29Busway Power Distribution ... Rod-Hanger Adaptor Packaged 10 per carton

Busway Systems Overview

Selector Chart (20-6500 Ampere)I-T-E was the first manufacturer to makea Busway System then known asBulldog Electric. Since its introduction in

Busway Selector Chart20-6500 Ampere

1932, Busway Systems have improvedand expanded into several designs tomeet the ever changing needs of the

GENERAL

electrical industry. The Busway SelectionChart below will help you in selecting theproper product to fit your requirements.

600 Volts or Less

Feature

AmpereRating

Conductor

Use

AC Service

DC Service

Voltage

Construction

MeetsElectricalStandard

1001502002253754005006008001000

1200

1350

1600

200025003000400050006000, 6500CopperAluminumIndoorOutdoor2W103W303W304W FN304W 200% N2-W3-W125250300600 volts or lessVentilatedNon-Ventilated

AIMS! UL857-1996®NEMA BU1-1999IEEE STD27 (ANSI 37.20)

NO 0-M1982CSA NO 0.4-M1982C22.2 NO »4-M1985

NO 27-197360439-1

IEC 60439-2PUBL. 1445486-Part 2: 1988159(1972)

JIS C8364400 Hz®D.C.®NEC-1993®NEMAG8-2, 1972, Part 14

ProductBustributionPlug-in and Feeder BuswaySiemens SentronPlug-in/Feeder

I

i

yy

yi/̂jyy/yy

yyyy

yyy/i.

y

/

y

yyy/

>/

y/V'

/•Lyyyyyyyy

SentronLow Amp

y

1

y

yy

yyyy

y

yyy/

yyyyyyyy/

y/

V

/t

y

XL-UPlug-in Feeder

/v

yv/

yyyyyy/iy/yv'j

v/

y

/y

y

yyyyyyyyyy©©®©©®/iyyy

XJ-LPlug-in

y

y

y/v/

yyy

/

yyyyyyi

©©®©©®

//y

BDPlug-in

yy

yyyyj

y

yyy

yi

y

y

yy

yyyy©©©©©©

/v'

IndustrialTrol-E-Duct

y/vy

yyyyyy

y

y

yyyy

yy

y

y

y

y

yy

CO DO

3§S Ss5

© Meets most applicable provisions of thisforeign standard.

©Used on both DC and 400Hz applications. Consultfactory for information.

©When busway is installed per manufacturer's recommen-dations, Siemens busway meets all applicable portions.

Siemens Electrical Products SPEEDFAX 2000

Page 3: Busway Power Distribution - DLE ELECTRIC SUPPLY - …dlelectricsupply.com/files/ETBH308.pdf ·  · 2016-02-29Busway Power Distribution ... Rod-Hanger Adaptor Packaged 10 per carton

Busway Power Distribution

BD® Plug-In (225 —1600 Ampere)225-1600 Amperes / 600 Volts or Less

SELECTION

AmpereRating

Plug In®10'- 0"StraightLengthCatalogNumber

CaseDimensions(inches)

ShippingWeightLb./Ft.

®ListPrice $

GroundBusAdderSuffix GK

®ListPrice $

90° Elbow Prefix

®S>CatalogNumber

ListPrice $

Switch-BoardConnec-tion®Prefix

ListPrice $

Building ExpansionFitting

CatalogNumber

ListPriceS

Aluminum3 Phase, 3 Wire 600V or Less

225400

600800

10001200

ABD302ABD304

ABD306ABD308

ABD310ABD312

4X» x 85641/« x &A

6X. x 8%6X« x 8%

12!4x87^•\2Ux8U

910

13142228

1010.1240.

1540.2160.

2440.3290.

37.37.

38.46.

46.46.

ALD302ALD304

ALD306ALD308

ALD310ALD312

1110.1180.

1270.1450.

1780.2030.

FEA302FEA304

FEA306FEA308

FEA310FEA312

760.800.

1070.1240.

1410.1730.

EPA302EPA304

EPA306EPA308

EPA310EPA312

2360.2770.

3150.4320.

4790.5670.

3 Phase, 4 Wire — Full Capacity Neutral 277/480V225400

600

800

10001200

ABD4024ABD4044

ABD4064

ABD4084

ABD4104ABD4124

4'/6 x 8%4M» X 8«

6Ms x 854

8% x 8%

12^x8'^12!4x8'^

10SS12

•\m

27

3138

1250.1570.

2170.

2520.

3160.4010.

37.37.

38.

46.

46.46.

ALD4024ALD4044

ALD4064

ALD4084

ALD4104ALD4124

1350.1440.

1620.

1730.

2290.2540.

FEA4024FEA4044

FEA4064

FEA4084

FEA4104FEA4124

840.920.

1220.

1390.

1680.1910.

EPA4024EPA4044

EPA4064

EPA4084

EPA4104EPA4124

2850.3330.

4170.

4910.

5580.7250.

Copper3 Phase, 3 Wire 600V or Less225

400600800100013501600

BDP302

BDP304BDP306

BDP308

BDP310

BDP313BDP316

4%B x ff/t

4K« x m4X« x 8%6K« x 8%6X« x 8%12X x 85*1 214x8%

9

121/13J518M

222829

1250.1890.2420.

3540.

3830.

5790.6170.

56.

56.58.58.58.83.118.

LDP301

LDP304LDP306

LDP308

LDP310

LDP313LDP316

1200.1390.1550.

1890.2040.

2820.2930.

FEP302

FEP304FEP306

FEP308

FEP310

FEP313FEP316

830.

960.1290.1560.

1760.2320.2370.

EJP302

EJP304EJP306

EJP308

EJP310

EJP313EJP316

2630.

3450.4080.

5760.

6230.

8160.8950.

3 Phase, 4 Wire — Full Capacity Neutral 277/480V225

4006008001000

BDP4024

BDP4044BDP4064

BDP4084

BDP4104

4M« x VA

4'/« x 8%4Xe X 8%

8X x 8%8% x m

12

14)415K2832

1620.

2730.3100.

4520.

5290.

56.

56.58.

58.58.

LDP4024

LDP4044LDP4064

LDP4084

LDP4104

1480.1810.1920.2500.

2730.

FEP4024

FEP4044FEP4064

FEP4084

FEP4104

940.

1170.1450.

1810.

1910.

EJP4024

EJP4044EJP4064

EJP4084

EJP4104

3220.

4480.5090.

6860.

8000.

"M" Rating / Standard RatingConversion Table

1000/A Square Inch"M" Rating

225400600800

10001200135016002000250030004000

Standard 55°C RatingBDP—

600800800

1000—13501600————

Right EdgewiseElbow (-2)

Left EdgewiseElbow (-4)

For inches / millimeters conversion, see page 583.

CD Consult local sales office for five foot length.©List prices are for standard construction, for higher

short circuit ratings add an "H" after the "D" or "P"{ABDH302 or BDPH302) and add 20% to the list price.Consult sales office for ratings.

®"GK" is an internal ground bus. For any other groundconfiguration, consult local sales office. List price isper foot. Please use following footage for fittings:

Elbow - 3 footSWB-1'End Cable Tap Box - 1'Center Cable Tap Box -10'Building Expansion - 10'

Suffix

-1

-2

-3

-4

Description

Right Flatwise

Right Edgewise

Left Flatwise

Left Edgewise

Appropriate suffix must be

added to Elbow Catalog

Number to order.

©Switchboard stub includes flange to cover cutout intop of indoor switchboard and 6" of bus insideswitchboard. Connecting hardware supplied byswitchboard manufacturer.

= Warehouse Stock

Siemens Electrical Products SPEEDFAX 2000 Discount Schedule M

Page 4: Busway Power Distribution - DLE ELECTRIC SUPPLY - …dlelectricsupply.com/files/ETBH308.pdf ·  · 2016-02-29Busway Power Distribution ... Rod-Hanger Adaptor Packaged 10 per carton

12

End Cable Tap Boxes are used to cable con-nect incoming service to BD Busway. Whenmounting busway sections flush against awall or a flat surface, the busway must bemounted with the offset to the right of theinstaller. This will permit the end cable tapbox to mount flush against the wall. BDBusway end cable tap boxes are providedwith robust wire bending space to makepulling cables less labor intensive.

End Cable Tap Boxes

A12”

1”

6”

B

C

Ordering Information ➀

Wire # Cable LugsAmp Catalog Housing Busbar Stub Dimensions Bend Per PhaseRating Number Size Size Lgth. “A” “B” “C” Space Wire Size

Aluminum 3 Phase - 3 Wire225A EBA302 4¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 1 6” 20¹⁄₂” 7” 16” 12” (1) #6-350MCM400A EBA304 4¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 2 6” 26” 8¹⁄₂” 18” 16” (1) #4-600MCM 600A EBA306 6¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 3 6” 30” 12” 18” 16” (2) #4-600MCM800A EBA308 6¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 4 6” 30” 12” 18” 20” (3) #4-600MCM

1000A EBA310 12¹⁄₈ x 8⁷⁄₈ (2) ¹⁄₄ x 3 6” 30” 18” 18” 20” (4) #4-600MCM 1200A EBA312 12¹⁄₈ x 8⁷⁄₈ (2) ¹⁄₄ x 4 6” 30” 18” 18” 20” (4) #4-600MCM

Aluminum 3 Phase - 4 Wire,100% Neutral225A EBA4024 4¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 1 6” 20¹⁄₂” 7” 16” 12” (1) #6-350MCM400A EBA4044 4¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 2 6” 26” 8¹⁄₂” 18” 16” (1) #4-600MCM600A EBA4064 6¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 3 6” 30” 12” 18” 20” (2) #4-600MCM800A EBA4084 8¹⁄₈ x 8⁷⁄₈ (1) ¹⁄₄ x 4 6” 30” 18” 18” 20” (3) #4-600MCM

1000A EBA4104 12¹⁄₈ x 8⁷⁄₈ (2) ¹⁄₄ x 3 6” 30” 18” 18” 20” (4) #4-600MCM 1200A EBA4124 12¹⁄₈ x 8⁷⁄₈ (2) ¹⁄₄ x 4 6” 30” 18” 18” 20” (4) #4-600MCM

Copper 3 Phase - 3 Wire225A ETB302 4¹⁄₁₆ x 8⁷⁄₈ (1) ³⁄₆₄ x 2 6” 20¹⁄₂” 7” 16” 12” (1) #6-350MCM400A ETB304 4¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 1¹⁄₂ 6” 26” 8¹⁄₂” 18” 16” (1) #4-600MCM600A ETB306 4¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 2 6” 26” 8¹⁄₂” 18” 16” (2) #4-600MCM800A ETB308 6¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 3 6” 30” 12” 18” 20” (3) #4-600MCM

1000A ETB310 6¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 4 6” 30” 12” 18” 20” (4) #4-600MCM 1350A ETB313 12¹⁄₈ x 8⁷⁄₈ (2) ¹⁄₄ x 3 6” 30” 18” 18” 20” (4) #4-600MCM 1600A ETB316 12¹⁄₈ x 8⁷⁄₈ (2) ¹⁄₄ x 4 6” 30” 18” 18” 20” (4) #4-600MCM

Copper 3 Phase - 4 Wire, 100% Neutral225A ETB4024 4¹⁄₁₆ x 8⁷⁄₈ (1) ³⁄₆₄ x 2 6” 20¹⁄₂” 7” 16” 12” (1) #6-350MCM400A ETB4044 4¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 1¹⁄₂ 6” 26” 8¹⁄₂” 18” 16” (1) #4-600MCM600A ETB4064 4¹⁄₁₆ x 8⁷⁄₈ (1) ¹⁄₄ x 2 6” 26” 8¹⁄₂” 18” 16” (2) #4-600MCM800A ETB4084 8¹⁄₈ x 8⁷⁄₈ (1) ¹⁄₄ x 3 6” 30” 18” 18” 20” (3) #4-600MCM

1000A ETB4104 8¹⁄₈ x 8⁷⁄₈ (1) ¹⁄₄ x 4 6” 30” 18” 18” 20” (4) #4-600MCM

➀ Includes busway stub. Total length added to run is 2’ for 225A and 400A Aluminum or 225A-600A Copper; 3’ for all others. Box is designed to connect to offset bus bar end. When it is to be connected to straight bus bar ends, an adaptor will be furnished upon request.

Consult local sales office for other fittings

Page 5: Busway Power Distribution - DLE ELECTRIC SUPPLY - …dlelectricsupply.com/files/ETBH308.pdf ·  · 2016-02-29Busway Power Distribution ... Rod-Hanger Adaptor Packaged 10 per carton

20

BD BuswayTypical Specifications1.0 General

A.Furnish and install a complete low impedance prefabricated busway distribution system as shown on the plans.

B.Busway shall be ____volts____phase____wire.C.The ampere ratings, approximate footage, fitting,

plug-in units, etc., are shown on the plans. The electrical contractor shall be responsible for routing the busway to coordinate with the other trades. Final field measurements shall be made by the contractor prior to release of the busway for fabrication.

2.0 Short-Circuit Rating and TestsA.The short-circuit rating of the busway shall be

(consulting engineer’s calculated required ratings), RMS symmetrical amperes which is the ultimate anticipated short-circuit current available at the source.

B.The short-circuit rating of the busway shall be determined according to UL Standard No. 857. This rating must be based upon actual tests at the rated short-circuit current for three (3) cycles.

3.0 Basic ConstructionA.Housing

1. The busway housing shall be formed of two identical halves of cold rolled steel, painted with polyester urethane powder paint to provide protection against corrosion.

2. The busway housing shall be totally enclosed non-ventilated for protection against mechanical damage and dust accumulation.

3. Casing ends and busbars of adjacent sections shall overlap to form a scarf lap joint.

B.Joint1.Each bus-bar shall be individually bolted to secure electrical connection.2.It shall be possible to disconnect any joint connection to allow physical removal of busway length without disturbing adjacent busway lengths.

C.Bus-bars1. The bus-bars shall be tin plated at all contact

surfaces.2. The temperature rise at any point in the busway

shall not exceed 55°C rise above ambient temperature when operating at rated load current.

3. Busbars shall be air insulated.4. Block type high impact non-tracking insulators

shall be used with the casing to support the busbars, retard the travel of power surges and increase the strength of the busway against short-circuit forces.

D.Plug-in Openings1. On plug-in busway plug-in openings shall be

spaced on 24-inch centers along both sides of busway and across the joints.

2. All openings shall be usable simultaneously.3. Busway shall be installed so that plugs are side

mounted to permit practical use of all ten plug-in openings.

4. It shall be possible to inspect the plug-in opening and bus-bars prior to the installation of the plug-in unit.

E.Support of Busway1. Hanger spacing shall be noted on layout

drawings and shall not exceed manufacturers recommendations.

2. Two hangers shall be provided with each busway section for convenient installation.

F.Underwriter’s Laboratory Listing1. All straight lengths, fittings, and plug-in units shall

be listed and marked in accordance with UL Standard No. 857.

4.0 Voltage DropA.The voltage drop (input voltage minus output voltage)

specified shall be based on the busway operating at full rated current at stabilized operating temperature in25°C ambient temperature.

B.The three-phase, line-to-line voltage drop shall not exceed 3.78 volts per hundred feet at 90% power factorconcentrated load, which condition may exist during motor starting.

5.0 Plug-in UnitsA.Plug-in units shall be____circuit breaker type

or____fusible switch type with quick-make/quick-break mechanism.

B.Plug-in units which cannot be operated directly from the floor shall be equipped with suitable means for hookstick operation.

C.The interrupting rating of circuit breaker plug-in units shall be [ ] RMS symmetrical amperes.

6.0 Plug-in Unit Safety DevicesA.Each plug-in unit shall be mechanically interlocked

with the busway housing to prevent installation or removal of plug-in units while the switch is in the ON position.

B.Plug-in enclosures shall make positive ground connection with the ground bus before the contact fingers make contact with the phase bars.

C.The plug-in units shall be equipped with internal barriers to prevent accidental contact of fish tape and conductors with live parts on the line side of the protective device during time of wire pulling.

D.Covers of all plug-in units must have “releasable” typeinterlocks to prevent the cover from being opened when the switch is in the ON position.

7.0 QualityA.All busway products shall be manufactured in a facility

which is Quality registered to ISO9001.

8.0 Approved SuppliersA.All major components shall be of the same

manufacturer as the busway. The busway and plug-in units shall be manufactured by Siemens, . . .