Tighten all electrical connections before energizing.
Branch circuit protection is required. Refer to the National Electrical Code (USA) or Canadian Electrical Code.
Additional control circuit overcurrent protection may be required.
Do not tap into L1 and L2 for applications above 600V, provide separately sourced control power unless transformer and
control wire are listed for use at the application voltage.
Maintain this equipment in accordance with guidelines of NFPA-70B, Electrical Equipment Maintenance
Bulletin 1109 200A / 400A / 600A Vacuum Starter Schematic and Wiring Diagrams - 3 Phase
PN-115930DIR 42052-148 (Version 04)Printed in U.S.A.
OP
TIO
NA
L A
UX
ILIA
RY
CO
NT
RO
L-P
AK
Wiring Diagram SchematicL3L2L1
T1 T2
MOTOR
T3
(43)
(44)
(51)
(52)
(63)
(64)
(71)
(72)
(A1)
2
3
4M
(13)
(14)
(21)
(22)
(A2)
WIRE "A"
#6 - 250 MCM
400 AMP. Max.
600 AMP. Max.
200 AMP. Max.
(2) 2/0 - 350 MCM
Lug Mounting Screws -- 125 - 145 Lb-Inches Conductor Set Screws -- 275 Lb-Inches
Coil Terminal Screws -- 7 Lb-Inches
TIGHTENING TORQUE
USE 75°C CU WIRE ONLY
(UNLESS OTHERWISE SPECIFIED ON DEVICE)
Lug Mounting Screws -- 180 - 210 Lb-Inches Conductor Set Screws -- 275 Lb-Inches
Coil Terminal Screws -- 7 Lb-Inches
TIGHTENING TORQUE(UNLESS OTHERWISE SPECIFIED ON DEVICE)
(2) 2/0 - 500 MCM Lug Mounting Screws -- 180 - 210 Lb-Inches
Conductor Set Screws -- 375 Lb-Inches
Coil Terminal Screws -- 7 Lb-Inches
TIGHTENING TORQUE(UNLESS OTHERWISE SPECIFIED ON DEVICE)
Line / Load Lug KitConnections for Local or Remote Pilot Devices
PILOT LIGHT
CONNECT TO COIL TERMINALS.
R
PUSH TO TEST PILOT LIGHT
R
1
4
TWO WIRE CONTROL DEVICE
1
3
3 POSITION SELECTOR SWITCH
TWO WIRECONTACTDEVICE
HANDOFF
AUTO
1 TO L.H.COIL TERM.(A1)
TWO OR MORE MOMENTARY CONTACTPUSHBUTTON STATIONS
START
STOP
START-STOP PUSHBUTTON
START
STOP1
2
3
2 POS SELECTOR SWITCH
ON OFF
1START
STOP1
2
3
TO L.H.COIL TERM.(A1)
(REMOVE WIRE "A")(REMOVE WIRE "A")
TO L.H.COIL TERM.(A1)
TO L.H.COIL TERM.(A1)
TO L.H.COIL TERM.(A1)
V
4
4
M
M
M
M
OPTIONAL AUXILIARY
(43)
(71)
(63)
(51)
(72)
(64)
(52)
(44)
(14)(13)
3O.L.
M
2
MSTARTSTOP
1
M(22)(21)
(A1) (A2)
1
SEPARATE AC SOURCE
3-WIRE CONTROL
CT1 CT2 CT3
GRDO.L.95 96 97 98
�
� N.O. (97 and 98) on electronic overload only
95 96
WARNING
CONFIDENTIAL AND PROPRIETARY INFORMATION. THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION OF
ROCKWELL AUTOMATION, INC. AND MAY NOT BE USED, COPIED OR DISCLOSED TO OTHERS, EXCEPT WITH THE AUTHORIZED WRITTEN
PERMISSION OF ROCKWELL AUTOMATION, INC.
Sheet
Size Ver
Of 11
A 00Dr. DateG. USHAKOW 2-10-10
SPECIFICATIONS FOR1 OR 2 PAGE INSTRUCTION SHEET4-1/4” W x 5-1/2” H - FINAL FOLD
MATERIALSIZE
FOLD
BODY STOCK WHITEBODY INK BLACK
FLAT
8-1/2" W x 11" H 4-1/4" W x 5-1/2" H
10000021654
Final Fold
4-1/4”
5-1/2”
PN-12345DIR 100000000 (Version 00)Printed in U.S.A.
11”
8-1/2”
Note: After folding---Printed in (Country where printed)* and instruction sheet number in lower left corner should be visible.
* The printing vendor may change the instruction sheet files to show the correct country.