Building Boq Sample

44
proposed pavilion at cooray play ground final Page 1 Item Description Qty. Unit Rate No. Rs. BILL NO.C DEMOLISHER Note: C.1 Item C.2 Item C.3 Item Total carried over to summary BILL NO. D EXCAVATION AND EARTH WORK Note: Rates shall be included for D.1 Excavation for column footings 375.00 D.2 30.00 D.3 490.00 1. Prior to do pricing the Contractor is adviced to do a detail inspection of the site related to all items mentioned under Bill No. C 2.Rate shall include carting away all unusable materials 3.Temporary support incidental to demolitions Allow for disconnection or plugging water, sewer connections and making good all damages to walls and floor etc. (Rate to be included necessary con. & cement & sand mortar) Purchesing of reusable items by the contractor.(Contractor has to offer a price for this marked as negative ) . Allow for removing two existing buildings size 20.00mx18.00m including foundation . 1. All necessary boarding supports and erection. 2. Striking or removal clearing, wetting etc. 3. Disposal of excess material and backfill. Excavation for wall foundations, depth n.e 1.0m Filling under floor ,earth of approved quality cleaned, spread,watered and well ramed in 150mm layers.

description

quantity of building construction

Transcript of Building Boq Sample

Sheet1

ItemDescriptionQty.UnitRateAmountNo.Rs.Rs.BILL NO.CDEMOLISHERNote:1. Prior to do pricing the Contractor is adviced to do a detail inspection of the site related to all items mentioned under Bill No. C2.Rate shall include carting away all unusable materials 3.Temporary support incidental to demolitionsC.1Allow for disconnection or plugging water, sewer connections and making good all damages to walls and floor etc. (Rate to be included necessary con. & cement & sand mortar)ItemC.2Purchesing of reusable items by the contractor.(Contractor has to offer a price for this marked as negative ) .ItemC.3Allow for removing two existing buildings size 20.00mx18.00m including foundation . ItemTotal carried over to summaryBILL NO. DEXCAVATION AND EARTH WORKNote:Rates shall be included for1. All necessary boarding supports and erection.2. Striking or removal clearing, wetting etc.3. Disposal of excess material and backfill.

D.1Excavation for column footings 375.00mD.2Excavation for wall foundations, depth n.e 1.0m30.00mD.3Filling under floor ,earth of approved quality cleaned, spread,watered and well ramed in 150mm layers.490.00mTotal carried over to summaryBILL NO.FCONCRETE WORKF1 - INSITU CONCRETENote:Rates shall be included for1. Mixing, handling, hoisting and depositing into position.2. Packing around reinforcement and vibrating.3. Curing and clearing as specified.Cement concrete grade 15 (25mm aggregate) for the following itemF1.1In 50mm thick under walls foundations60.00m2F1.2In 50mm thick under column footings159.00m2F1.3In 75mm thick floor. 70.00m3Concrete mixture for the following items will be grade 25 (20mm aggregrate) redy mixed concrete including pumping where necessaryF1.4In column footings.150.00m3F1.5In column, up to F.F.L8.00m3F1.6In column, from F.F.L to 3.6m level28.00m3F1.7In column, from 3.6m level to pavilion floor level level21.00m3F1.8In column above pavilion floor36.00m3F1.9In plinth beams16.00m3F1.10 In stair case 12.60mF1.11In intermediate beams.55.00mF1.12In upper floor beams52.00mF1.13In floor slab 108.00mF1.14In tiers180.00mF1.15In roof beams35.00mCement concrete grade 20 (20mm aggregate) for the following items.F1.16In ground floor lintols5.00mF1.17In 600mm wide 75mm thick vanity top 1.00mF2 - FORM WORKNote:Quality of the form work should be approved by the engineer prior to erection.F2.1In sides of column bases260.00mF2.2In sides of columns up to F.F.L80.00mF2.3In sides of columns from F.F.L to 3.6m level290.00mF2.4In sides of columns from 3.6m level to pavilion floor level215.00mF2.5In sides of column pavilion floor level 395.00mF2.6In side and soffit of plinth beams150.00mF2.7In sides and soffit of intermeddiate beams.500.00mF2.8In sides and soffit of roof beams290.00mF2.9In sides and soffit of pavilion floor slab and tiers1,785.00mF2.10In sides and soffits of upper floor beams475.00mF2.11In sides and soffits of lintols in ground floor70.00mF2.12In sides and soffits of staircase90.00mF2.13In sides and soffits of vanity top12.00mF3 - REINFORCEMENT IN INSITU CONCRETENote:Rates shall be included for1. Cleaning, cutting, bending, fabricating with gauge 18 binding wire and placing in position.2. Holding and supporting including temporary fixing supports, hingers, binding wire spaces & tor steel stools.which is required for the proper completion of the work.3. Providing all necessary laps.4.Precast cement distance blocks should be same grade of concrete with 5mm aggregate.5. Plain rounded Mild steel of characteristic strength 250 N/mm to BS44496. High Yield steel of characteristic strength 460 N/mm to BS4449 & 4461Mild steel round bar diameter n.e. 10mm for the following itemsF3.1In column up to F.F.L135.00kgF3.2In Columns from F.F.L to 3.6m level475.00kgF3.3In columns from 3.6m to pavilion floor level 360.00kgF3.4In column from pavilion floor level to roof level 650.00kgF3.5In intermediate beam1,300.00kgF3.6In floor beams 1,850.00kgF3.7In roof beams800.00kgF3.8In plinth beam410.00kgHigh-yield tor steel bars diameter n.e. 10mm for the following items.F3.9In lintols in ground floor200.00kgF3.10In floor slabs 8,150.00kgF3.11In tiers10,000.00kgF3.12In staircase945.00kgF3.13In vanity top100.00kgHigh-yield tor steel bars diameter 10-16mm for the following items.F3.14In column bases 3,500.00kgF3.15In column up to F.F.L350.00kgF3.16In columns from F.F.L to 3.6m level820.00kgF3.17In columns from 3.6m to pavilion floor level925.00kgF3.18In columns above pavilion floor level1,650.00kgF3.19In plinth beams850.00kgF3.20In intermediate beams4,150.00kgF3.21In floor beams5,400.00kgF3.22In roof beams2,700.00kgHigh-yield tor steel bars diameter above 16mm for the following items.F3.23In column up to F.F.L850.00kgF3.24In columns from F.F.L to 3.6m level2,950.00kgF3.25In columns from 3.6m to pavilion floor level2,200.00kgF3.26In columns above pavilion floor level4,150.00kgTotal carried over to summaryBILL NO GMASONRY WORKSG1 - BRICK WORK 225mm thick brick work in cement and sand mortar 1:5 for the following itemsG1.1In ground floor Up to3.687m800.00mG1.2In ground floor from 3.687m to 8.637m860.00G1.3In upper floor390.00m112.5mm thick brick work in cement and sand mortar 1:5 for the following itemsG1.4In ground floor80.00mG1.5In upper floor50.00mG2 - RUBBLE WORKG2.1Random rubble masonry in cement & sand mortar 1:5 in foundations,steps and tiers.205.00mTotal carried over to summaryBILL NO HWATER PROOFINGNote:The water proofing contractor (or sub contractor) should be a registered specialist contractor at the ICTAD in the category of water proofing.The contractor shall submit a written warranty of at least 5 year to cover on the quality of the material, suitability of the material for the situation and the workmanship including water tightness.The water proofing material shall confirm to relevant British, Euro or ASTM specifications.H.1Water Proofing the inner surface of walls and floor Application of "Baralastic" polymer modified cementitious waterproofing agent after cleaning the subtrate all as per manufacturer's specifications with 10 years warranty on application.Rate shall include for ponding test for a 300mm water height kept for a period of 48 hours in toilet floor and walls up to 300mm.40.00mTotal carried over to summaryBILL NO KMETAL WORKNote:The work shall include supplying, fabricating and installation of doors and windows etc. made of anodized aluminium sections having a minimum anodic coating of 15 microns thickness & bronze colour. Rate shall be included for 5mm thick clear glass, rubber beadings, stainless steel screws, rawl plugs, neoprene gaskets, locks, aluminium hinges, bar hinges and push plates etc. (Extrusions to be of 1.6mm for minimum thickness for doors & 1.5mm for windows,1.2mm for partion). Samples shall be submitted for the approved of Engineer before use.K.1Supply and fix bronze anodized aluminium framed glazed /alu. Paneled door with aluminium louvers on top as per detail. (D1 - 1050mm x 2400mm)02Nr.K.2Supply and fix bronze anodized aluminium framed glazed /alu. Paneled door with aluminium louvers on top as per detail. (D2 - 900mm x 2400mm)04Nr.K.3Supply and fix heavy duty PVC framed PVC panelled door as per detail. (D3 - 800mm x 2100mm)15Nr.K.4Supply and fix bronze anodized aluminium framed glazed window with aluminium louvers on top as per detail. (W1 - 2300mm x 1500mm)08Nr.K.5Supply and fix bronze anodized aluminium framed glazed window with aluminium louvers on top as per detail. (W2 - 1800mm x 1500mm)02Nr.K.6Supply and fix bronze anodized aluminium framed glazed window with aluminium louvers on top as per detail. (W3 - 1500mm x 1500mm)01Nr.K.7Supply and fix bronze anodized aluminium framed glazed fanlight as per detail. (F1 - 750mm x 1100mm)01Nr.K.8Supply and fix bronze anodized aluminium framed glazed fanlight as per detail. (F2 - 2400mm x 650mm)02Nr.K.9Supply and fix bronze anodized aluminium framed glazed fanlight as per detail. (F3 - 2200mm x 650mm)02Nr.K.10600mm high stainless hand rail consisting 25mm dia.uprights@ 900mm c/c , 3 nos 20mm dia.horizontal bar fixed to the uprights and complete in order with necessary nut & bolits as per detail in mazzanine floor . Rate to include application of two coats of anticorossive and two coats of enamal paint as per detail in stair case. All G.I. bar should be hevy duty95.00lmTotal carried over to summaryBILL NO. LWOOD WORKL1 - JOINERYNote:1. Rates shall be included for timber doors, windows and fanlight 100mm x 75mm frames, mullions, transom and the like shall be well seasoned luxury class timber.2. Timber for doors, windows and fanlight casements and louvers and trellis work and 28mm thick sashes shall be well seasoned Luxury class timber unless otherwise specified.3. Rates for doors, windows and fanlight shall include for the following;a. Heavy quality oxidized brass ironmongery and locks..b. M.S.hold fasts concrete spur stones, 5mm thick glass panes and glazing bars.c. Apply two coats of wood preservative meterial to sides of frames in touch with masonary / concrete surface.d.Preparing and painting frames & sashes with two coats enamel paint. e.Timber classification is according to Sri Lanka State Timber Corporation Classification. L.1Door in 100mm x 75mm luxury timber frame and 28mm thk. luxury timber panelled sash with heavy duty brass fittings(3nos 100mmx75mm hinges and 150mm barrol bolt and union brand mortice lock) ( DW- 3600mm x 2400mm)10Nr.Total carried over to summaryBILL NO .PROOF AND ROOF PLUMBINGP.1Supply and fix zinc alum profile roofing sheet (minimum base metal thickness of 0.4mm) and minimum thickness of 0.47mm, laid on150mmx75mmx15mm x 2.3mm channel purlin @ 1200mm c/c with joints to be properly connected with an adequate side lap to ensure water tightness along the entire length and complete to working order.1,900.00mP.2Supply and fix proprietary coated zinc alum gutter (minimum base metal thickness of sheet 0.4mm and minimum total thickness 0.47mm) complete with end caps, running joints etc. All joints to be properly connected with an adequate side laps not less than 225mm length and with sealant to ensure water tightness along the entire length of the gutter and including angle iron gutter brackets 25x25x3mm at 450mm centers with an adequate slope as directed and including application of two coats of each anticorrosive paint and enamel paint to all steel surfaces to match the gutter fix in position.( Inner size of 150mm x 175mm )160.00mP.3Supply and fix zinc aluminum (minimum base metal thickness of sheet 0.4mm and minimum total thickness 0.47mm) down pipes - 100mm x 100mm approved quality with all necessary specials. Down pipes brackets @ 1m c/c300.00mP.4Supply and errecting steel roof truss as per detail. Rate to include application of two coats of anticorossive paint and two coats of enamal paint.09Nr.Total carried over to summaryBILL NO. QPLUMBING AND SANITARY INSTALLATIONSNote:Any other make/brand that has equivalent performance characteristics are considered as equivalent provided such fittings met with following criteria(a) Has an authorized local agent in Sri Lanka(b) The local agent has been in the trade of the offered make for not less than 5 years(c) The offered sanitary fittings has a 10 Year manufacturer's warranty issued by the agent.(d) The cistern mechanism shall have an assurance for the availability of spares for the next 3 years.(e) The fittings are manufactured in conformity to BS, JIS, A.S.T.M., A.S. or S.L.S. standards(f) The dimensions are and performance characteristics are in par with the stated model.(g)The brands that may be considered as equivalent are "Ideal" brand, or "Twyford" brand or any other approved make which prior approval to be obtained(h) Plumbing work should be carried out by a plumber licensed by the CMC and executed in accordance with the specifications and requirement of the Water Supply & Drainage Division of C.M.C.(i) Provisions should be made by the tenderers to submit the necessary plans and the payment of service connection fee to the National Water Supply & Drainage Board.(j) All water conduits shall be of standard quality PVC tubes of approved quality and approved by the National Water Supply & Drainage Board gauge to be 1000 UPVC quality.(k) Rates shall be inclusive of bends, valves, reduces joints,end caps etc. Necessary for the installation of service including excavation, laying, testing, refilling of trench & making good surface complete.Q.1Supply & fix/lay 20mm dia PVC pipes. 100.00lmQ.2Supply & fix/lay 25mm dia PVC pipes. 180.00lmQ.3Supply and fix squatting pan with foot rest of "Rocell" brand or approved equivalent.06Nr.Q.4Supply and fix low level plastic cistern for squatting pan of "Rocell" brand or approved equivalent including connecting pipe between tank and squatting pan.06Nr.Q.5Supply and fix white vitreous china floor standing close coupled semi back to wall water closet suite with wash down flushing with 6/3 liters dual flushing has horizontal outlet with vario drain bend and two lateral holes for bottom water connection , cistern with water inlet from rear of "Rocell" brand or approved equivalent complete to working order inclusive of universal bend of "Rocell" brand.07Nr.Q.6Supply and fix Chromium plated hand Bidet Spray of "American Standared" or approved equivalent.07Nr.Q.7Supply and installation of vanity type wash basin of "American Standard" brand, with waste & plug or approved equivalent. On concrete vanity slab finished with 3/4" thick approved polished granite tile in black colour. ( Vanity top concrete slab & Granite tile laying measured separatly.)Rate to be included approved quality piller tap.16.00Nr.Q.8Supply and fix mirror of size 2700mm x 450mm. 04Nr.Q.9Supply and fix mirror of size 800mm x 450mm02Nr.Q.10Supply and fix 12mm approved quality bib tap. 15NrQ.11Supplying and fix 12mm dia. chromium plated Angle valve.29Nr.Q.12Supply and fix stainless steel soap tray.02Nr.Q.13Supply and fix chromium plated 600mm long Single Towel Bar of "Rocell" brand & model "Charming" or approved equivalent.02Nr.Q.14Supplying and fixing 25mm wheel valve "Pegler" Brand or approved equivalent.06Nr.Q.15Supplying and fixing chromium plated 20mm consealed valve for shower.02Nr.Q.16Supplying and fixing approved quality chromium plated 20mm shower rose.02Nr.Q.17Supplying and fixing wall hang ceramic urinal with necessary fittings.04Nr.Q.18Allow for connection fee for water supply Rate to be included for breaking the road surface & reinstate temporary after laying the line as directed.Pro.sum35,000.00Q.19Allow for new connection for water. Pro.sum.60,000.00Q.20Allow for water Pressure testing for PVC pipes. Item10,000.00Total carried over to summaryBILL NO.SELECTRICITYNote:All electrical constructions should be according to IEE regulations (17th edition or later) and subject to the instructions of the electrical officer concerned. Jobs attend beyond condition will not be approved please.All switches & socket outlets shall be plated type "Clipsal","Orange" or Cabtree (make:-"Atco","BG" original or equivalent) starter and the tube should be Thron, Philips or Osram.All Ceiling should be KDK,National Mitsubishi, Hittachi(original Japan) with guarantee card from the authorized dealer.All Distribution Boadrs should be incorporated with genuine Merlin Gerin, A.B.B., Hager,F & G, Clipsal make MCB's (Miniature Circuit Breakers) and Cabtree,F & G, Clipsal ,Merlin Gerin make RCD's (Residual Current Devices) and Terrasaki,Merlin Gerin, Dormans Smith,Biticano, Clockner moeller make MCCB's (Moulded Case Circuit Breakers). A certificate or invoice along with their Company seal and part No./Numbers should be produced at the time of payment.All CFL bulbs shall be "Energy star 3 " or above, with minimum 1 year warranty, purchased from authorised dealer.Minimum 1 year warranty from the building handed over date shall be given for all electrical equipment including fans, light fittings, CFL bulbs, etc. Warranty cards shall be submitted by the contractor to the Projects Engineer.All light fittings shall be approved by the project architect/ electrical engineer prior to the installationGROUND FLOORS.1Supply & install approved surface mounted type three tube 1200mm -3x36W complete fluorescent lamp fittings -1200mmx 600mm-with polished aluminium parabolic mirror reflectors & cross blades as shown in the electrical layout & complete wiring using round blocks, ceiling roses,1mm Cu/PVC/PVC cable, flexible cable, sunk switches, sunk nut boxes and conduits or plastic casings etc. where necessary.56Nrs.S.2Supply & install approved type 1200mm, 2x36W fluorescent tube complete lamp fittings & complete wiring by using same items as in No.01 above. 09Nrs.S.3Supply & install approved type wall bracket outdoor weather proof complete lamp fittings with approved type CFL 20W (cool white) as shown in the Ground floor electrical layout & complete wiring by using same items as in No.01 above. 28Nrs.S.4Supply & install approved type wall bracket indoor complete lamp fittings with approved type CFL 15W (cool white) & complete wiring using round blocks, ceiling roses,1mm Cu/PVC/PVC cable, flexible cable, sunk switches, sunk nut boxes and conduits or plastic casings etc. where necessary.04Nrs.S.5Supply & install approved type sweep ceiling fans with dimmer type regulators with a switch -1400mm (55") dia. according to the electrical layout & complete wiring by using the same items as in No. 01 above + 2.5mm Cu/PVC earth cable.48Nrs.S.6Supply & install approved type 5A sunk plug bases with switches as shown in electrical layouts & complete wiring by using 1mm Cu/PVC/PVC cable + 2.5mm Cu/PVC earth cable, sunk nut boxes & conduits or plastic casing etc. where necessary.10Nrs.S.7Supply &install approved type 13A sunk plug bases (5A fused) with switches & complete wiring with 2.5mm Cu/PVC/PVC cable + 2.5mm Cu/PVC earth cable, sunk nut boxes & conduits or casing etc. where necessary in radial circuits. 08Nrs.S.8Supply &install approved type 15A sunk plug bases with switches & complete wiring by using 2.5mm Cu/PVC/PVC cable + 2.5mm Cu/PVC earth cable, sunk nut boxes & conduits or casing etc. where necessary. 03Nrs.S.9Supply and install an approved wall mounted type Distribution Board (DB-G) fabricated in zinc coated sheet not less than 1.5 mm thickness with indicator lights 03 nos. for three phases, 30A 3P+N bus bars and all other necessary accesories, surface finish should be powder coated texured finish R.A.L.7032 consist of following items of approved type at the ground floor.01Nr.32A 4P MCCB (25kA) 01 Nr.20A 4P MCB 01 Nr.(for upper floor)40A (30mA) 2P RCD 01Nr.20A 2P MCB 02 Nrs.16A 1P MCB 01 Nr.10A 1P MCB 03 Nrs.6A 1P MCB 05 Nrs.S.10Supply and install approved ABC type wall mounted type Distribution Boards (SDB-G1 and SDB-G2) consist of following of approved types.02Nrs.20A 2P MCB 01 Nr.40A (30mA) 2P RCD 01 Nr.16A 1P MCB 01 Nr.10A 1P MCB 03 Nrs.6A 1P MCB 05 Nrs.S.11Supply and install 4x10mm Cu/PVC/PVC cable as the load wire with all necessary accesories.10mS.12Supply and install 2x6mm Cu/PVC/PVC cable as the load wire for SDB-G1 and SDB-G2 with all necessary accesories.120mS.13Supply and install an earthing system with 50mm dia. GI pipe of length 1800mm earth electrodes. Each electrode underground should be covered by a gully of 1'x1' and shall be available for visual inspection. Number of rods required to obtain the necessary resistance shall be determined by the contractor. All metal parts of the building shall also be earthed.Testing of earth resistance after installation shall be done by the contractor in the presence of the project Electrical Engineer/Technical officer. All costs for testing shall be borne by the contractor.1ItemS.14Supply and install 6mm2 Cu/PVC earth cable in conduits, from the earth point to the distribution board and from DB-G to SDB-G1 and SDB-G2. Cost shall include all necessary accessories and materials including excavation and backfilling.25mS.1530A three phase underground power connection from CEB. Cost shall include all associated costs including expenditure to obtain necessary reports from a chartered electrical Engineer.Pro.Sum300,000.00UPPER FLOORS.16Supply & install approved type wall bracket indoor complete lamp fittings with approved type CFL 15W (cool white) & complete wiring using round blocks, ceiling roses,1mm Cu/PVC/PVC cable, flexible cable, sunk switches, sunk nut boxes and conduits or plastic casings etc. where necessary.19Nrs.S.17Supply & install approved type low bay (18" dia) complete lamp fittings outside plated in black with approved type CFL 26W (cool white) & complete wiring by using same items as in No.01 above. 42Nrs.S.18Supply and install an approved wall mounted type Distribution Board (DB-U) fabricated in zinc coated sheet not less than 1.5 mm thickness with indicator lights 03 nos. for three phases, 30A 3P+N bus bars and all other necessary accesories, surface finish should be powder coated texured finish R.A.L.7032 consist of following items of approved type at the upper floor.01Nr.40A 4P Isolator 01 Nr.40A (30mA) 2P RCD 02 Nrs.20A 2P MCB 02 Nrs.6A 1P MCB 10 Nrs.S.19Supply and install approved ABC type wall mounted type Distribution Board (SDB-U1) consist of following of approved types.01Nr.20A 2P MCB 01 Nr.40A (30mA) 2P RCD 01 Nr.6A 1P MCB 05 Nrs.Space for 1P MCB 02 Nrs.S.20Supply and install 2x6mm Cu/PVC/PVC cable as the load wire for SDB-U1 with all necessary accesories.60mS.21Supply and install 4x6mm Cu/PVC/PVC cable as the load wire for DB-U with all necessary accesories.10mS.22Supply and install 6mm2 Cu/PVC earth cable in conduits, from the MDB to the DB-U with all necessary accesories.70mTotal carried over to summaryBILL NO: TFLOOR/ WALL AND CEILING FINISHEST1 - FLOOR FINISHESRendering 20mm thick in cement and sand 1:2 in floors cut finish with neat cement slurry in following items. T.1.1In ground floor,tiers and steps ect.1100.00mT.1.2In upper floor with tiers590.00mT.1.3In stair ways50.00mT.1.4Supplying and laying 300mmx300mm nonslip floor tiles bedded in cement and sand mortar 1:3 . Rate to be included the cost of 1:3 mortar levelling bed as per drawing in ground floor toilet.180.00mT.1.5Supplying and laying 200mmx200mm nonslip floor tiles bedded in cement and sand mortar 1:3 . Rate to be included the cost of 1:3 mortar levelling bed as per drawing in ground floor toilet.25.00mSkirting 100mm x 12mm thick in cement and sand 1:3 projected or flush to walls finished with colour pigment neat cement including forming groove for the following itemT.1.6In ground floor180.00mT.1.7In stairway40.00mT.1.8In upper floor225.00mT.1.9Polished Granite 20mm thick absolutely black for vanity top approved quality , laid on 12mm thick cement sand 1:3 screed level off using cement slurry and 1mm joints to be absolutely in line and flush and grout.12.00mT2 - WALL AND CEILING FINISHEST.2.1300mm x 200mm approved quality polished glazed wall tilling on plastered surface of walls joints finished with coloured grout to match with colour of tiles in ground floor toilet . Wall plaster measured seperately.365.00mT.2.216mm thick plastering to plinth with cement & sand mortar 1:3 and floated with cement.100.00mT.2.312mm thick plastering to internal walls with cement and sand mortar 1:3 to a rough finish (screed backing to receive wall tiles) in ground floor( toilet). 365.00m16mm thick external wall and column plastering with lime, cement and sand mortar 1:5 to a semi rough finish for the following items. T.2.4In ground floor Up to3.6m600.00mT.2.5In ground floor from 3.6m to 8.6m475.00mT.2.6In upper floor900.00mT.2.7In isolated column175.00mT.2.8Reveals (width n.e 300mm) in ground floor215.00m16mm thick internal plastering in walls and columns with cement and sand mortar I:5 finish semi rough for the following items. T.2.9In ground floor up to 3.6m1,700.00mT.2.10In ground floor over 3.6m450.00mT.2.11In upper floor900.00mT.2.12In isolated column275.00mT.2.13Reveals (width n.e 300mm) in ground floor195.00mT.2.1410mm thick plastering with cement & sand mortar 1:3 finished with lime putty in soffit of stair ways.22.00mTotal carried over to summaryBILL NO VPAINTINGApplication of plaster coatings of thickness not less than 2mm using "Joint compound powder / Skimcoat ", or approved equivalent to walls, slab, beam, column facings.Rate shall include for sand papering and surface preparation in following items.V.1In ground floor walls , columns up to 3.6m1715.00mV.2In ground floor walls , columns over 3.6m450.00mV.3In upper floor walls , columns 900.00mV.4In ground floor isolated column175.00mV.5In upper floor isolated column275.00mV.6Soffit of floor slab ans tiers, sides and soffit of beams, stair case in ground floor1625.00mColour washing to internal walls with one coat of primer and two coats of approved quality and colour emulsion paint for the following items Including preparation of surfaces.V.7In ground floor walls , columns up to 3.6m1,715.00mV.8In ground floor walls , columns over 3.6m450.00mV.9In upper floor walls , columns 900.00mV.10In ground floor isolated column175.00mV.11In upper floor isolated column275.00mV.12Soffit of floor slab ans tiers, sides and soffit of beams, stair case in ground floor1,625.00mColour washing to external walls with two coats of approved quality and colour weathershield paint after applying one coat of primer for the following items Including preparation of surfaces.V.13In ground floor walls , columns up to 3.6m615.00mV.14In ground floor walls , columns over 3.6m475.00mV.15In upper floor walls , columns 900.00mTotal carried over to summaryBILL NO WDRAINAGE SYSTEMSNote:1.The work should be carried out by a contractor licensed by the CMC and in accordance with the regulations of the CMC for soil drainage.2. Backfilling of excavations in trenches and pits for drains and manholes must be compacted and excess to be disposed as directed at expenses of the contractor. Rate to be included for dewatering, pumping,shoring and cleaning the site on completion.3.The gauge of pipes to be 600 UPVC.4. Rates shall be inclusive of bends, valves, reduces joints,end caps etc. necessary for the installation of service.W.1Supply & fix/lay 40 mm dia. PVC Type 600 waste pipes. (approx.)55.00mW.2Supply & fix/lay 50 mm dia. PVC Type 600 waste pipes. (approx.)70.00mW.3Supply & fix/lay 110mm dia. PVC sewer/strom water pipes. 60.00mW.4Construction of gully internal size of 300mm x300mm & depth up to 450mm as per detail drawing. Rate to include for excavation, necessary formwork, lifting hooks, supplying P.V.C.gully trap in fill with grade 20 concrete and 20mm thick cement & sand rendering in 1:2 mix trowel smooth with neat grey cement to all internal surfaces , exposed external surfaces and forming channel with 1:6 benching. Including 75mm thick RCC cover slab reinforced wth 6mm dia mild steel at 100mm c/c both ways.06Nr.W.5Construction of RCC sewer manhole internal size of 600mmX450 mm & depth< 1000mm as per detail drawing. Rate to include for excavation, necessary formwork, lifting hooks and 20mm thick cement, sand rendering in 1:2 mix 2% approved water proofing compound, trowel smooth with neat grey cement to all internal surfaces, exposed external surfaces and forming channel with 1:6 benching. Including 75mm thick RCC cover slab reinforced wth 10mm dia tor steel at 150mm c/c both ways.08Nr.W.6Construction of strom water brick manhole internal size of 300mm x 300mm & depth upto 375mm, consist of 75mm thick Grade 15 concrete base and 112mm thick brick masonry side walls in 1:3 cement sand mix , 1/2" thick cement rendering in 1:2 to internal & external exposed faces of walls finished smooth with neat cement floating, with 50mm thick Grade 20 RCC cover slab with 6mm dia. M.S. rods @ 100mm c/c both ways. Rate to include for excavation, necessary formwork , lifting hooks & 75mm thick concrete pad.01Nr.W.7Supply and fix PVC Catch pit floor trap of size 100mm dia. Internal including PVC grating embedded in the floor.18Nr.W.8Allow for connecting storm water drain to existing CMC drain.itemTotal carried over to summary

&8proposed pavilion at cooray play ground finalPage &P

Sheet2

SUMMARY

BILL NODESCRIPTIONAMOUNTRS.BILL NO.01PRELIMINARIESBILL NO. CDEMOLITIONBILL NO. DEXCAVATION AND EARTH WORKBILL NO. FCONCRETE WORKBILL NO. GMASONRY WORKSBILL NO. HWATER PROOFINGBILL NO. KMETAL WORKBILL NO. LWOOD WORKBILL NO. PROOF AND ROOF PLUMBINGBILL NO. QPLUMBING AND SANITARY INSTALLATIONSBILL NO. SELECTRICAL INSTALLATIONBILL NO. TFLOOR/WALL AND CEILING FINISHESBILL NO. VPAINTINGBILL NO. WDRAINAGE SYSTEMS

SUB TOTAL

ADD 10% CONTINGENCIES

TENDER PRICE (BID PRICE)

ADD 11% VAT

FINAL COST (WITH TAXES)

SUMMARYBILL NODESCRIPTIONAMOUNTRS.BILL NO.01PRELIMINARIESBILL NO. CDEMOLITIONBILL NO. DEXCAVATION AND EARTH WORKBILL NO. FCONCRETE WORKBILL NO. GMASONRY WORKSBILL NO. HWATER PROOFINGBILL NO. KMETAL WORKBILL NO. LWOOD WORKBILL NO. PROOF AND ROOF PLUMBINGBILL NO. QPLUMBING AND SANITARY INSTALLATIONSBILL NO. SELECTRICAL INSTALLATIONBILL NO. TFLOOR/WALL AND CEILING FINISHESBILL NO. VPAINTINGBILL NO. WDRAINAGE SYSTEMSSUB TOTAL

ADD 10% CONTINGENCIES

TENDER PRICE (BID PRICE)

ADD 11% VAT

FINAL COST (WITH TAXES)SIGNATURE OF TENDERER ..DATE:

lal/2015/ cooray playground