    Buffer storage for direct steam generation

    Wolf-Dieter Steinmann *, Markus Eck

    German Aerospace Center (DLR), Institute of Technical Thermodynamic, Pfaffenwaldring 38-40, D-70569 Stuttgart, Germany

    Received 13 October 2004; received in revised form 29 April 2005; accepted 11 May 2005Available online 14 July 2005

    Abstract

    Fast reaction times and high discharge rates make steam accumulators a promising option for compensation of fasttransients in insolation for solarthermal systems using steam as working medium. Using the volume of components likeseparator drums or heat exchangers for storage of pressurized hot water is a cost-effective approach to integrate bufferstorage capacity. While the basic steam accumulator shows a decline in pressure during the discharge process, there arealso concepts maintaining constant pressure. The integration of latent heat storage material allows an increase in vol-umetric storage capacity. The availability of steam accumulators for compensation of fast transients also helps toreduce the requirements concerning reaction time and discharge rate for storage systems intended for supplying storedenergy over longer periods. 2005 Elsevier Ltd. All rights reserved.

    Keywords: Solar power; Energy storage; Steam accumulator; Ruths; Direct steam generation; Solarthermal power plants; Steam cycle

    1. Introduction

    The availability of cost effective storage systems playsan important role for an increased market penetration ofsolarthermal power plants. Different concepts for inte-grated thermal storage units are currently under devel-opment for parabolic trough systems. These conceptscan be classified according to the storage capacity. Theaim of buffer storage systems is the compensation of fast

    transients in solar insolation which are usually not pre-dictable. Characteristic requirements for these bufferstorage systems are short reaction times and high dis-charge rates while the thermal capacity is usually inthe range of 510 min. Buffer storage systems are

    intended to protect the components of the power plantfrom the effects of high thermal transients resulting fromsudden variation in solar insolation. The integration ofbuffer storage capacity simplifies the control of thepower plant and allows an extended reaction time forbackup systems, which are intended to compensate long-er periods of reduced insolation. Steam accumulatorsare especially suited to meet the requirements for bufferstorage in solar steam systems, providing saturated

    steam at pressures up to 100 bar. The introduction ofsteam accumulators in solarthermal power plants canprofit from practical experience gained in operating sim-ilar storage systems in fossil fired facilities over decades.These storage systems are used in process industry tobalance demand and generation of steam. In the Berlinisland grid, a power plant with 50 MW electric powerwas operated with steam accumulators of 67 MW h stor-age capacity over a period of more than 60 years (Beck-mann and Gilli, 1984).

    0038-092X/$ - see front matter 2005 Elsevier Ltd. All rights reserved.

    doi:10.1016/j.solener.2005.05.013

    * Corresponding author. Tel.: +49 711 6862 785; fax: +49 7116862 747.

    E-mail address: [email protected] (W.-D. Steinmann).

    Solar Energy 80 (2006) 12771282

    www.elsevier.com/locate/solener

    mailto:[email protected]:[email protected]
  • 8/6/2019 Buffer Storage for Direct Steam Generation

    2/6

    2. Basic concept of steam accumulators

    The direct storage of saturated or superheated steamin pressure vessels is not economic due to the low volu-metric energy density. Instead, steam accumulators usesensible heat storage in pressurized saturated liquidwater (Goldstern, 1970). They profit from the high vol-umetric storage capacity of liquid water for sensible heatdue to its high specific heat capacity. Steam is producedby lowering the pressure of the saturated liquid duringdischarge. Fig. 1 shows the scheme of a steam accumu-lator. Since water is used both as storage medium andworking medium high discharge rates are possible, whilethe capacity is limited by the volume of the pressure ves-sel. The volume specific thermal energy density dependsstrongly on the variation of the saturation temperatureresulting from the pressure drop during discharge, char-acteristic values are in the range of 2030 kW h/m3.During the charging process either the temperature ofthe liquid water is increased by condensation of super-heated steam or the mass in the volume is increased byfeeding saturated liquid water into the system. If super-heated steam is used, the pressure in the vessel increasesduring the charging process while there is only a littlevariation of the liquid storage mass. If saturated liquid

    is fed into the steam accumulator, the pressure remainsconstant. A steam accumulator can also be charged indi-

    rectly; here, a heat exchanger is integrated into the liquidvolume. The medium flowing in the heat exchanger neednot be water, heat from a source working at lower pres-sure can be used. In sliding pressure systems (also calledRuths storage systems) saturated steam leaves the stor-age vessel during the discharge process. Fig. 2 showsthe amount of steam produced from 1 m3 of liquid waterduring a pressure drop of 1 bar dependent on the initialsaturation pressure. The range of steam production inFig. 2 corresponds to a thermal energy between0.26 kW h/bar/m3 and 0.19 kW h/bar/m3. The satura-tion pressure affects the rate of steam production in dif-ferent ways: at higher pressures, the pressure dependentchange of saturation temperature decreases, so thechange in sensible energy in the liquid water volume be-comes smaller. The density of saturated liquid water isreduced with pressure resulting in a lower volumetric en-ergy density. On the other side, mass specific energy

    Steam Discharging

    IsolatedPressure Vessel

    Liquid Phase

    Steam

    Steam Charging

    Liquid waterCharging / Discharging

    Steam Discharging

    IsolatedPressure Vessel

    Liquid Phase

    Steam

    Steam Charging

    Liquid waterCharging / Discharging

    Fig. 1. Scheme of sliding pressure steam accumulator.

    0 20 40 60 80 1000.26

    0.27

    0.28

    0.29

    0.3

    0.31

    0.32

    0.33

    0.34

    0.35

    Saturation pressure [bar]vol.spec.steamp

    roduction/pressuredrop

    [kg/bar/m

    3]

    Fig. 2. Mass of produced saturated steam associated withpressure reduction of 1 bar in a steam accumulator dependenton saturation pressure in vessel; mass of produced steam refers

    to volume of liquid water.

    Nomenclature

    A, B, C constants for the Antoine equationcliquid specific heat capacity of liquid phaseh 0 specific enthalpy saturated liquid

    h00 specific enthalpy saturated steamhexit specific enthalpy of steam at exit of pressure

    vesselDhevaporate heat of vaporizationDhevaporate,m average heat of vaporization for dis-

    charge processDhevaporate,ref reference value heat of vaporization for

    Watson equation

    mliquid mass of liquid phase in vesselmSteam mass of saturated steam provided during

    discharge process

    mVessel mass of water in pressure vesselpstart pressure at begin of discharge processpend pressure at end of discharge processpVessel pressure in vesseltsat saturation temperatureuVessel internal energy of water in pressure vessel

    1278 W.-D. Steinmann, M. Eck / Solar Energy 80 (2006) 12771282

  • 8/6/2019 Buffer Storage for Direct Steam Generation

    3/6

    needed for evaporation is smaller at higher pressures.Fig. 2 shows that for a given pressure drop steam accu-mulators operated at a lower pressure level provide moresaturated steam; if the pressure at the end of the dis-charge process is fixed, a storage system starting at ahigher initial pressure level might provide more steam

    due to the larger variation of pressure.

    3. Integration of steam accumulators in solarthermal

    power plants

    The practical feasibility of direct steam generation(DSG) in parabolic trough collectors has been provenin recent years, reaching temperatures of 400 C at pres-sures of up to 100 bar (Eck et al., 2003). The applicationof steam accumulators for this technology is a straight-forward solution for integration of buffer storage capac-

    ity in solarthermal power plants using this collectorconcept. Fig. 3 shows the flow sheet for a DSG powerplant with integrated steam accumulator. If the steamproduction of the collector field exceeds the demand ofthe turbine, the surplus steam is condensed in the steamaccumulator. During periods of reduced insolation,steam is taken from the steam accumulator to supportor replace the steam production of the solar field. It isadvantageous to operate solar steam systems in the so-called recirculation mode; here, not the complete waterthat is fed into the collector field is evaporated. Wetsteam exits the evaporation section and enters a separa-tor. The gas phase is either fed into a saturated steamturbine or superheated in another section of the collectorfield, the liquid phase is pumped back to the inlet of theevaporator section of the collector field.

    Regarding the integration of steam accumulators, itis a cost effective approach to combine storage andphase separation in a single component. Fig. 4 shows

    the scheme of a DSG-power plant operated in recircula-tion mode: wet steam from the evaporation section ofthe collector field enters the steam accumulator/separa-tor. Here, the phases are separated. During the chargingprocess, the amount of saturated liquid leaving the ves-sel is smaller than the amount entering the volume

    through the wet steam feed line. The pressure in thesteam accumulator/separator remains constant, no spe-cific charging devices for condensation of steam are nec-essary inside the volume. The steam accumulator isdischarged by lowering the pressure in the volume andextracting steam. This concept demands almost no addi-tional hardware, modifications mainly affect the opera-tion strategy of the power plant.

    Steam accumulators can also be applied in systemswhich use thermal oil as heat transfer medium in solarcollectors provided steam is produced for electricity gen-eration or as process steam (Fig. 5). Again, combining

    GPower Block

    DSG-

    SolarField

    Steama

    ccumulator

    saturated steam

    Fig. 3. Simplified scheme of solarthermal power plant withdirect steam generation (DSG) in parabolic troughs and

    integrated steam accumulator.

    G

    Power Block

    DSG-

    SolarFieldoperatedin

    recirculationmode

    Steama

    ccumulator

    usedasseparator

    wet steam

    saturated steam

    saturated liquid

    Fig. 4. DSG-power plant with steam accumulator also used asphase separator at the exit of the collector field.

    GPower Block

    SolarField

    Steama

    ccumulator

    usedasevaporator

    Thermal Oil Loop saturated steam

    Fig. 5. Parabolic trough power plant using oil as heat transfermedium in collectors; indirect charging of steam accumulator

    which is also used as heat exchanger.

    W.-D. Steinmann, M. Eck / Solar Energy 80 (2006) 12771282 1279

  • 8/6/2019 Buffer Storage for Direct Steam Generation

    4/6

    the steam accumulator with an already existing compo-

    nent offers a cost-effective option for introducing bufferstorage capacity. This kind of solarthermal systems re-quires a heat exchanger to transfer thermal energy fromthe thermal oil to the water/steam loop; the pressurizedliquid water volume in this heat exchanger can be usedfor energy storage. The steam accumulator is chargedindirectly by the thermal oil flowing in a tube register lo-cated in the liquid volume. By variation of the liquidwater level the charge state of the steam accumulatorchanges.

    Steam accumulators provide saturated steam; ifsuperheated steam is needed, a second storage systemcan be connected to the exit of the steam accumulator.Candidate concepts for this second storage system useeither solid storage media like concrete or non-pressur-ized liquids like molten salt for sensible heat storage.In most solar steam applications, only a small fractionof the thermal energy is needed for superheating. In asolarthermal power plant using parabolic troughs, only1015% of the thermal energy is needed for superheatingsteam (Tamme et al., 2004), so the contribution of theadditional storage system is significantly smaller thanthe share of the steam accumulator (Fig. 6).

    4. Constant pressure concepts

    In a Ruths-type steam accumulator the steam pressuredrops during discharge. For some applications, a storagesystem providing steam at constant pressure is advanta-geous. One option to avoid a pressure drop is the applica-tion of a separate flash evaporator (Fig. 7): the saturatedliquid water taken from the steam accumulator is depres-surized externally, cold water is fed into the storage vesselto keep the water level constant, mixing of hot and coldwater must be minimized, thermal stress resulting fromfilling the pressure vessel with cold water must be consid-

    ered. Another option for constant pressure storage is the

    integration of phase change material (PCM) into the stor-age vessel partly replacing the liquid water (Fig. 8). Here,the thermal energy associated with the phase change be-tween liquid and solid state is used for isothermal energystorage. PCMs usually exhibit a low thermal conductivityso layers of this material must be thin to ensure a suffi-cient heat transfer rate. One option to fulfill this demandis the encapsulation of PCM in small containers placedinside the liquid volume. Using PCM is not only attrac-tive regarding the avoidance of thermo-mechanical stress

    resulting from temperature transients, the characteristicvolume-specific storage capacity of PCMs is in the rangeof about 100 kW h/m3. Compared to the correspondingvalue for water (2030 kW h/m3), the integration ofPCM helps to increase the storage capacity of a givenpressure vessel.

    5. Physical model of sliding pressure steam

    accumulator

    For the physical model it is assumed that there is no

    heat transfer between the environment and the fluid vol-

    Saturated Steam

    Super heated SteamSteamA

    ccum

    ulator

    SolidMediumH

    eatStorage

    Fig. 6. Combination of steam accumulator with additionalsensible storage system to provide superheated steam.

    Steama

    ccu

    mulator

    external Flash evaporatorsaturated steam

    hot

    cold

    charge line

    saturated liquid

    Fig. 7. Constant pressure concept; external depressurization.

    Saturated Steam

    Feedwater

    EncapsulatedLatent Heat Storage Material

    Fig. 8. Steam accumulator with integrated latent heat storage

    material.

    1280 W.-D. Steinmann, M. Eck / Solar Energy 80 (2006) 12771282

  • 8/6/2019 Buffer Storage for Direct Steam Generation

    5/6

    ume inside the pressure vessel or between the walls of thepressure vessel and the fluid volume. The fluid inside thepressure vessel should be always in thermal equilibrium.

    During the discharge process, the change in internalenergy of the liquid water volume with mass mvessel inthe pressure vessel of the steam accumulator corre-

    sponds to the enthalpy flow transported by the exitingmass flow dmVessel:

    dmVesseluVessel hexitdmVessel 1

    It is assumed that the specific exit enthalpy hexit equalsthe specific enthalpy h00 of saturated steam at pressure

    pVessel so from (1):

    uVesseldmVessel mVesselduVessel h00pVesseldmVessel 2

    The integration of Eq. (2) provides the mass of saturatedsteam that is provided during the discharge of the steamaccumulator. Fig. 9 shows the amount of saturated

    steam delivered by the steam accumulator dependingon the final pressure at the end of the discharge processfor different initial pressures. The dashed lines demon-strate the application of the diagram for the example dis-cussed in Section 6.

    The following assumptions allow a quick estimationof the storage capacity for discharge from pressure pstartto pend for a given liquid volume with mass mliquid:

    complete heat for evaporation is provided by theliquid phase,

    specific heat capacity of liquid water is approximatedby average value cliquid,m for saturated liquid water at

    average pressure pm = (pstart + pend)/2, specific heat of vaporization is approximated by aver-

    age value Dhevaporate,m a pm = (pstart + pend)/2,

    the change in liquid mass mliquid during depressuriza-tion is neglected.

    With these assumption, the mass of saturated steammSteam provided by the steam accumulator is

    mSteam

    Dhevaporate;m

    mliquid

    cliquid;m

    tsat

    pstart

    tsat

    pend

    3

    The left side of Eq. (3) represents the enthalpy providedby the steam accumulator during the discharge processwhile the right side is the change of internal energy ofthe liquid water inside the pressure vessel.

    Two empirical correlations for saturation tempera-tures tsat and heat of vaporization Dhevaporate are applied(Reid et al., 1988):

    Antoine equation:

    tsat C

    B

    A lnpsat bar C

    A 11.934; B 3985; C 234.1

    4

    Watson equation:

    Dhevaporate Dhevaporate;ref1 t 273.15=647

    1 tref 273.15=647

    0.38

    5

    Dhevaporate,ref is the known heat of vaporization for a se-lected temperature tref.

    Combination of Eqs. (3)(5) provides an estimationfor the total mass of saturated steam mSteam providedduring the discharge process starting at pressure pstartwith final pressure pend depending on the mass of liquid

    water mliquid:

    mSteam mliquidcliquid;mB

    1Alnpstart

    1Alnpend

    Dhevaporate;ref1 B

    AlnpmC273.15

    647

    1tref273.15=647

    0.38 6

    6. Steam accumulators for solar direct steam

    generation

    Fig. 10 shows the DISS test facility for Direct Steam

    Generation in parabolic troughs. This test facility isoperated in a pressure range between 30 and 100 barand steam outlet temperatures up to 400 C, the peakthermal power is 2 MW (Eck et al., 2003). A separatordrum divides the collector into an evaporation sectionand a superheating section. By using this pressure vesselfor hot water storage the separator can be operated as asteam accumulator. During the charging process, theamount of liquid water leaving the drum is smaller thanthe mass flow of the liquid phase provided by the solarcollector to the separator, the water level in the drumrises. This concept demands no specific devices for steam

    condensation and allows charging at constant pressure.

    10 20 30 40 50 60 70 80 90 1000

    50

    100

    150

    200

    250

    Pressure at end of discharge process [ bar]

    vol.spec.m

    assofsteam[

    kg/m3]

    pstart=100bar

    pstart=80bar

    pstart=60bar

    psta

    rt=40bar

    pstart=

    20bar

    Fig. 9. Volume specific mass of saturated steam provided bysteam accumulator for different initial pressures and pressuredrops. Dashed line indicates example discussed in Section 6with initial pressure = 100 bar and final pressure 55 bar; steamaccumulator delivers approx. 90 kg saturated steam per m3

    storage volume.

    W.-D. Steinmann, M. Eck / Solar Energy 80 (2006) 12771282 1281

  • 8/6/2019 Buffer Storage for Direct Steam Generation

    6/6

    Assuming a pressure drop from 100 bar to 55 bar, Fig. 9provides a volume specific saturated steam productionof about 90 kg/m3 during the discharge. The volumefor saturated liquid water of the drum is approx. 4 m3,so about 360 kg saturated steam can be provided Thenominal mass flow rate of the collector is 1.2 kg/s, sothe steam accumulator can replace the collectors forabout 5 min.

    7. Conclusion and outlook

    Steam accumulators represent an attractive option forfacilitating the operation of solarthermal power plants byoffering short time energy storage. The integration ofsteam accumulators mainly aims at the compensationof fast transients in insolation. Thermo-mechanical stress

    resulting from fluctuations in solar irradiation can belimited in the components of the power plant by theavailability of steam accumulators, the response time ofstorage systems intended for operation over severalhours can be extended if steam accumulators are usedin the initial phase of storage operation. This responsetime affects the investment costs for storage systems, sosteam accumulators also help to improve the cost effi-ciency of long time storage.

    The investment costs for steam accumulators aredominated by the pressure vessel, the use of components

    like steam drums, feedwater tanks or deaerators as stor-age vessels offers an interesting option for the limitationof additional investment costs for steam accumulatorsystems. Here, the development of adapted operationstrategies is required.

    Regarding the pressure vessel of the steam accumula-tor, the detailed analysis of the thermo-mechanical stressin the storage vessel during charging/discharging willhelp to optimize the storage systems. An interesting as-pect here is also the flow field of gas phase and liquidphase inside the pressure vessel which might be con-trolled by inserts to limit temperature gradients in thevessel wall.

    References

    Beckmann, G., Gilli, P.V., 1984. Thermal Energy Storage.

    Springer-Verlag, Berlin.Eck, M., Zarza, E., Eickhoff, M., Rheinlander, J., Valenzuela,L., 2003. Applied research concerning the direct steamgeneration in parabolic troughs. Solar Energy 74, 341351.

    Goldstern, W., 1970. Steam Storage Installation. PergamonPress, Oxford.

    Reid, R.C., Prausnitz, J.M., Poling, B.E., 1988. The Propertiesof Gases & Liquids, fourth ed. McGraw-Hill BookCompany.

    Tamme, R., Laing, D., Steinmann, W.-D., 2004. Advancedthermal energy storage technology for parabolic trough.ASME J. Solar Energy Eng. 126, 794800.

    G

    Collectors for water evaporation

    Water/steam separatorused as steam accumulator

    Collectors for steam superheating

    Recirculation pump

    Steam turbine

    Fig. 10. Scheme of the DISS test loop for direct steam generation in parabolic troughs with separator used as steam accumulator.

    1282 W.-D. Steinmann, M. Eck / Solar Energy 80 (2006) 12771282