bs21s06
-
Upload
hungpm2013 -
Category
Documents
-
view
214 -
download
0
Transcript of bs21s06
-
8/21/2019 bs21s06
1/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
iedor
disc
lose
dw
ithou
tperm
iss
ion
".
6-1ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
Section 6
Provisioning
-
8/21/2019 bs21s06
2/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-2ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
Upon completion of this section you will be able to:
define the configuration and the type of the BSC,
define the capacity of a BSC.
Objectives
-
8/21/2019 bs21s06
3/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-3ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
Contents
BSC Provisioning
BSC 12000 Configuration
BSC 6000 Configuration
BSC 6000/12000 Configuration
BSC 12000HC Configuration
BSC 6000/12000/12000HC
-
8/21/2019 bs21s06
4/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-4ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
Nbr of BTS
Hardware
limits
BSC
model
BSC
product
range
Nbr of Cells
Nbr of PCM/site
Nbr of LAPD channels
Nbr of TRX
Software
limits
Load
limits
BSC Provisioning
-
8/21/2019 bs21s06
5/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-5ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
BSC 12000 product portfolio 1201 1202 1203 1204 1205
BSC type 1 2 3 4 5
Maximum sites (with BSCB) 28 60 92 124 138
Maximum number of TDMA 64 128 192 256 320
Numb. of LAPD ports 8 16 24 32 40
Number of PCM (E1 or T1) 48 48 48 48 48
CCS7 links 2 4 4 4 6
TCU (with E1) 12 12 12 12 12
TCU (with T1) 14 14 14 14 14
BSC 12000 Configuration
1 - Maximum Capability
-
8/21/2019 bs21s06
6/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-6ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
BSC 12000 Configuration
2 - Control Cabinet
BSC 12000 product portfolio 1201 1202 1203 1204 1205BSC type 1 2 3 4 5
CPU-OMU 1 1 1 1 1
CPU-MPU 1 1 1 1 1
CPU-BIFP 1 1 2 2 2
SICX 1 1 1 1 1
SICD8V 1 2 3 4 5
SS7 1 2 2 2 3
SUP/SUP2 1 1 1 1 1
MMU/MMU-IDE 1 1 1 1 1
SLS/SLS2 1 1 1 1 1
x 2
-
8/21/2019 bs21s06
7/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-7ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
BSC 12000 product portfolio 1201 1202 1203 1204 1205BSC type 1 2 3 4 5
Switching shelf (SWG)
SWC 1 1 1 1 1
MSW 2 2 2 2 2
SWE 2 2 2 2 2
ECI 1 1 1 1 1
RCB 1 2 3 4 5
TSCB 2 2 2 2 2
BSCB 12 12 12 12 12DDTI 10/24 10/24 10/24 10/24 10/24
ALA 1 1 1 1 1
x 2
BSC 12000 Configuration
3 - Equipment Cabinet
-
8/21/2019 bs21s06
8/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-8ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
BSC 6000 product portfolio 602 604 606 608 610
BSC type 1 2 3 4 5
Maximum number of sites* 7 15 23 124 138
Maximum number of TDMA 32 64 96 128 160
Number of LAPD ports 8 16 24 32 40
Number of PCM (E1 or T1) 12 20 28 40 48
SS7 links 2 2 4 4 4
TCU (with E1) 7 7 7 7 7TCU (with T1) 9 9 9 9 9
BSC 6000 Configuration
1 - Maximum Capability
* 1 LAPD per site
-
8/21/2019 bs21s06
9/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-9ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
BSC 6000 Configuration
2 - Control Cabinet
x 2
BSC 6000 product portfolio 602 604 606 608 610BSC type 1 2 3 4 5
CPU-OMU 1 1 1 1 1
CPU-MPU 1 1 1 1 1
CPU-BIFP 1 1 2 2 2
SICX 1 1 1 1 1SICD 2 4 6 8 10
CCS7 1 1 2 2 2
SUP 1 1 1 1 1
MMU 1 1 1 1 1
SLS 1 1 1 1 1
-
8/21/2019 bs21s06
10/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
ied
or
disc
lose
dw
ithou
tperm
iss
ion
".
6-10ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
BSC 6000 product portfolio 602 604 606 608 610
BSC type 1 2 3 4 5Switching shelf (SWG)
SWC 1 1 1 1 1
MSW 1 1 1 2 2
SWE 1 1 1 2 2
ECI 1 1 1 1 1
RCB 1 2 3 4 5
TSCB 2 2 2 2 2
BSCB 0 0 0 12 12
DDTI 6 10 14 20 24
ALA 1 1 1 1 1
x 2
BSC 6000 Configuration
3 - Equipment Cabinet
-
8/21/2019 bs21s06
11/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecop
iedor
disc
lose
dw
ithou
tperm
iss
ion
".
6-11ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
ENGINEERING RULES: Maximum number of sites according to the number of Abis/BSCB boards.
With redundancy (N+1) of BSCB boards
Number of extra
BSCB
BSC 12000
type 1
BSC 12000
type 2
BSC 12000
type 3
BSC 6000/12000
type 4
BSC 6000/12000
type 5
0 7 15 23 31 39
2 16 24 32 40 48
3 25 33 41 54 57
4 28* 42 50 58 665 51 59 67 75
6 60 68 76 84
7 77 85 93
8 86 94 102
9 92 103 111
10 112 120
11 121 129
12 124* 138
* The BSCB board is under-utilized: some of its ports are not used due to a lack of SICD.
BSC 6000/12000 Configuration
BTS LAPD Concentration
-
8/21/2019 bs21s06
12/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecopie
dor
disc
lose
dw
ithou
tperm
iss
ion
".
6-12ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
BSC 12000HC Configuration
Estimated Capacity with Three Different Subscriber Profiles
BSC 12000 product portfolio 1201 1202 1203 1204 1205
BSC type 1 2 3 4 5
Nortel standard (Erlangs) 480 930 1200 1200 1200
Nortel standard (BHCA) 19200 37200 48000 48000 48000High mobility (Erlangs) 360 630 1100 1200 1200
High mobility (BHCA) 14400 25200 44000 48000 48000
Short call duration (Erlangs) 280 560 880 1100 1100
Short call duration (BHCA) 27200 54500 85600 107000 107000
-
8/21/2019 bs21s06
13/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecopie
dor
disc
lose
dw
ithou
tperm
iss
ion
".
6-13ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000
BSC 6000/12000/12000HC
Capacity Comparison
BSC product 610 610 1205 1205HC
CPU MPU/BIFP type CPU66 CPU120 CPU120 CPU133
Nortel standard (Erlangs) 600 600 1200 1200
Nortel standard (BHCA) 24000 24000 48000 48000High mobility (Erlangs) 360 600 700 1200
High mobility (BHCA) 13650 24000 26000 48000
Short call duration (Erlangs) 240 440 640 1100
Short call duration (BHCA) 23000 42000 60750 107000
-
8/21/2019 bs21s06
14/14
"Con
fiden
tia
linforma
tion--m
ayno
tbecopie
dor
disc
lose
dw
ithou
tperm
iss
ion
".
6-14ProvisioningPE/TRD/CN/4021 12.04/EN October, 2000