BRG-100 product data ink · 2015. 4. 28. · Product data H.F. X-ray Generator BRG-100 X-Ray...
Transcript of BRG-100 product data ink · 2015. 4. 28. · Product data H.F. X-ray Generator BRG-100 X-Ray...
-
Product data H.F. X-ray GeneratorBRG-100
-
Product data H.F. X-ray GeneratorBRG-100
X-Ray 'Generators-of-Choice'For high-end hospital & clinical applications.
BRG-100 Generator
The 'heart' of the CPl system drives every major conventional /
digital imaging system on the market today.
Pulsed & conventional fluoroscopy - all in one compact cabinet.
Optional
Dose Area
Product (DAP)
Optional
Digital
Interface
Board for
Integrated
Solutions
Easy-to-access
for setup and
service
Compact size
L16"x W22"x H48"
L406mm x W559mm x
H1237mm
Low Speed Starter
or Integrated
Dual-Speed Starter
Module - multiple
stator compatible.
16 Bit CPU for
fast, flexible
processing
Universal or
Dedicated AEC
Interface
100 kHz +
Output
Frequency
FET Inverter
Modules
RAD or RF
32/40/50/65/80/100 kW
Special Procedures 100 kW
H.V. Module
1 Phase 230 VAC
3 Phase 400 or 480 VAC
-
Tecnical data
BRG-100Product data H.F. X-ray Generator 3
BRG-100 32 kW* 42 kW* 50 kW 65 kW 80 kW 100 kW
Application Radiographic Radiographic or RF Radiographic or RF Radiographic or RF Radiographic or RF Radiographic or RF
and Special Procedures
Generator Type High Frequency High Frequency High Frequency High Frequency High Frequency High Frequency
100kHz + 100 kHz + 100 kHz + 100 kHz + 100 kHz + 100 kHz +
kV (Radiographic) 40-150 kV 40-150 kV 40 -150 kV 40 -150 kV 40 -150 kV 40 -150 kV
kV (Fluoroscopic) N/A 40-125 KV 40 -125 kV 40 -125 kV 40 -125 kV 40 -125 kV
mA Range RAD 10-400 mA 10-500 mA 10-630 mA 10-800 mA 10-1000 mA 10-1000 mA
mA Range - FLUORO N/A 0.5-6.0 mA 0.5-6.0 mA 0.5-6.0 mA 0.5-6.0 mA 0.5-6.0 mA
continuous continuous continuous continuous continuous
mAs Range Non AEC 0.5 - 630 mAs 0.5 - 630 mAs 0.5 -1000 mAs 0.5 -1000 mAs 0.5 -1000 mAs 0.5 -1000 mAs
Timer Range, sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec.
1 Phase, 230 VAC 1 Phase, 230 VAC
Line Nominal/Phase 3 Phase 3 Phase 3 Phase 3 Phase 3 Phase 3 Phase
400 or 480 VAC 400 or 480 VAC 400 or 480 VAC 400 or 480 VAC 400 or 480 VAC 400 or 480 VAC,
Line Voltage Range ±10% ±10% ±10% ±10% ±10% ±10%
High Voltage Ripple (typ.)
-
16.5(420)
AUX
BRG-100 R/F CONSOLE
AUX 1 AUX 2
10.9(278)
3.5(90)
12.3(312)
3.5(90)
12.3(312)
3.5(90)
12.3(312)
BRG-100 RAD CONSOLE
16(406)
RIGHT SIDE
18(457)
22(559)
11.8
(300
)18
.2(4
63)
36.1
(917
)
48.7
(123
7)
FRONT
BRG-100 DIMENSION
Dat
a su
bjec
ted
to a
ltera
tion
with
out
prio
r no
tice.
BR
G-1
00-
10/
2004
BRG-100Product data H.F. X-ray Generator 4
ESSE 3 STR. GENOVA 299/4 10024 MONCALIERI (TO) – I tel +39 011 681 03 01 fax +39 011 681 31 87 e-mail [email protected] web : www.4ci.com
ESSE 3 Via Garibaldi 3014022 Castelnuovo D.B. (AT)tel +39 011 99 27 706 fax +39 011 99 27 506 e-mail [email protected] web : www.4ci.com