BREWSTER VILLAGE HOMESTEAD BATHING SUITE ALTERATION

13
0A SHEET ELEVATION APPEARS ON SHEET DETAIL APPEARS ON DETAIL NUMBER DIRECTION DETAIL IS CUT SHEET SECTION APPEARS ON SECTION NUMBER DIRECTION SECTION IS CUT ELEVATION NUMBER DIRECTION OF ELEVATION SHEET ELEVATION APPEARS ON ELEVATION NUMBER WINDOW NUMBER GRID DESIGNATION ELEVATION REVISION CLOUD AROUND REVISED ITEMS ROOM NAME ROOM NUMBER SYMBOL KEY DETAIL SECTION INTERIOR ELEVATION DOOR NUMBER DESCRIPTION ROOM NAME & NUMBER ELEVATION ELEVATION DATUM COLUMN GRID WALL TYPE WALL RATING WALL ID WINDOW TYPE DOOR TYPE PLAN KEYNOTE ACCESSORY KEYNOTE REVISION DEMOLITION KEYNOTE CEILING KEY CEILING TYPE CEILING HEIGHT EQUIPMENT TYPE 2 ROOM 101 2 A351 2 A351 2 A351 2 A351 W-1 101 2 1 A1 1A FIRST FLOOR 100'-0" TYPE MARK E1 EQUIPMENT DESCRIPTION PROJECT NO. DATE DESIGNED DRAWN SHEET NO. McMahon provides this drawing and data, regardless of form; as instruments of service. All rights including copyrights are retained by McMahon. The client and/or recipient agrees to the fullest extent permitted by law to indemnify and hold McMahon harmless for any reuse of or changes made to the original drawing or data without prior written consent by McMahon. 1445 McMAHON DRIVE NEENAH, WI 54956 Mailing: P.O.BOX 1025 NEENAH, WI 54957-1025 Tel: (920) 751-4200 Fax: (920) 751-4284 www.mcmgrp.com 4/30/2021 4:08:30 PM C:\Users\aprochnow.MCM\OneDrive - McMahon Associates\Documents\62000156_OC Brewster Village Homestead [email protected] A001 APRIL 19, 2021 AAP MAG HOMESTEAD BATHING SUITE ALTERATION 3300 W. BREWSTER STREET, APPLETON, WI 54914 BREWSTER VILLAGE O0002-06-20-00156 TITLE SHEET HOMESTEAD BATHING SUITE ALTERATION BREWSTER VILLAGE 3300 W. BREWSTER STREET, APPLETON, WI 54914 SHEET INDEX PROJECT LOCATION MAP DESIGN TEAM ARCHITECTURAL McMAHON 1445 McMAHON DRIVE NEENAH, WI 54956 (920) 751 - 4200 PROJECT MANAGER: MARLEY GAST E - MAIL: [email protected] STRUCTURAL McMAHON 1445 McMAHON DRIVE NEENAH, WI 54956 (920) 751 - 4200 PROJECT MANAGER: DAN BRELLEN E - MAIL: [email protected] HVAC McMAHON 1445 McMAHON DRIVE NEENAH, WI 54956 (920) 751 - 4200 PROJECT MANAGER: JOEL CLARY E - MAIL: [email protected] PLUMBING McMAHON 1445 McMAHON DRIVE NEENAH, WI 54956 (920) 751 - 4200 PROJECT MANAGER: ED ERICKSON E - MAIL: [email protected] ELECTRICAL McMAHON 1445 McMAHON DRIVE NEENAH, WI 54956 (920) 751 - 4200 PROJECT MANAGER: JILL FITZSIMONS E - MAIL: [email protected] PROJECT LOCATION SHEET NO. SHEET DESCRIPTION GENERAL A001 TITLE SHEET X X A011 FIRST FLOOR LIFE SAFETY PLAN X X A012 SECOND FLOOR LIFE SAFETY PLAN X X ARCHITECTURAL A211 WALL KEY AND PLANS X X A411 INTERIOR ELEVATIONS AND DETAILS X X PLUMBING P001 PLUMBING GENERAL NOTES, SYMBOLS & ABBREVIATIONS X X P200 PLUMBING PLANS X HVAC H001 HVAC GENERAL NOTES, SYMBOLS & ABBREVIATIONS X X H201 OVERALL HVAC PLAN X X H501 HVAC SCHEDULES AND DETAILS X X ELECTRICAL E001 ELECTRICAL SYMBOLS AND ABBREVIATIONS X E201 OVERALL SECOND FLOOR ELECTRICAL PLAN-AREA C X E202 ELECTRICAL PLANS X IMPORTANT NOTICE: THE DRAWINGS AND THE SPECIFICATIONS TOGETHER REPRESENT THE CONSTRUCTION DOCUMENTS, AND AS SUCH, MUST BE USED TOGETHER AS THE BASIS OF DESIGN. THE CONTRACTOR IS SPECIFICALLY INSTRUCTED NOT TO LIMIT THEIR UNDERSTANDING OF THE SCOPE OF THIS PROJECT BASED UPON THE SPECIFICATIONS INDEX. THE CONTRACTOR IS RESPONSIBLE TO REVIEW ALL INFORMATION IN BOTH THE DRAWINGS AND SPECIFICATIONS, AND IS THEREFORE, REQUIRED TO PROVIDE ALL DEFINED, AND REASONABLY IMPLIED, SCOPE OF WORK NO MATTER WHERE IT APPEARS IN THE CONSTRUCTION DOCUMENTS. IN ADDITION, THE CONTRACTOR IS TO REVIEW ANY FORMALLY PROVIDED MODIFICATIONS, CLARIFICATIONS, ADDENDUMS AND/OR OTHER INFORMATION AND INCORPORATE THAT INFORMATION INTO THE CONTRACTOR'S UNDERSTANDING OF THE SCOPE OF THE PROJECT. DHS SUBMITTAL: FEBRUARY 24, 2021 ISSUED FOR BIDDING: APRIL 19, 2021 NO. DATE REVISION X X X X

Transcript of BREWSTER VILLAGE HOMESTEAD BATHING SUITE ALTERATION

0A

SHEET ELEVATION APPEARS ON

SHEET DETAIL APPEARS ON

DETAIL NUMBER

DIRECTION DETAIL IS CUT

SHEET SECTION APPEARS ON

SECTION NUMBER

DIRECTION SECTION IS CUT

ELEVATION NUMBER

DIRECTION OF ELEVATION

SHEET ELEVATION APPEARS ON

ELEVATION NUMBER

WINDOW NUMBER

GRID DESIGNATION

ELEVATION

REVISION CLOUD AROUND REVISED ITEMS

ROOM NAME

ROOM NUMBER

SYMBOL KEY

DETAIL

SECTION

INTERIOR ELEVATION

DOOR NUMBER

DESCRIPTION

ROOM NAME & NUMBER

ELEVATION ELEVATION DATUM COLUMN GRID

WALL TYPE

WALL RATING

WALL ID

WINDOW TYPE

DOOR TYPE

PLAN KEYNOTE

ACCESSORY KEYNOTE

REVISION

DEMOLITION KEYNOTE

CEILING KEY

CEILING TYPECEILING HEIGHT

EQUIPMENT TYPE

2

ROOM101

2A351

2A351

2A351

2A351

W-1

101

21

A1 1A

FIRST FLOOR100'-0"

TYPE MARKE1EQUIPMENT DESCRIPTION

PROJECT NO.

DATE

DESIGNED DRAWN

SHEET NO.

McM

ahon

pro

vides

this

draw

ing

and

dat

a, r

egar

dles

s of

for

m;

as

inst

rum

ents

of s

ervic

e. A

ll rig

hts

inclu

ding

cop

yrig

hts

are

reta

ined

by

McM

ahon

. The

clie

nt a

nd/o

r re

cipie

nt a

gree

s to

the

fulle

st e

xten

t pe

rmitt

ed b

y la

w to

inde

mni

fy a

nd

hold

McM

ahon

har

mle

ss fo

r any

re

use

of o

r cha

nges

mad

e to

the

orig

inal

dra

wing

or d

ata

with

out

prio

r writ

ten

cons

ent b

y M

cMah

on.

1445

McM

AHO

N D

RIV

E N

EEN

AH, W

I 549

56M

ailin

g: P

.O.B

OX

1025

NEE

NAH

, WI 5

4957

-102

5Te

l: (9

20) 7

51-4

200

Fa

x: (9

20) 7

51-4

284

ww

w.m

cmgr

p.co

m

4/30

/202

1 4:

08:3

0 PM

C:\U

sers

\apr

ochn

ow.M

CM

\One

Driv

e - M

cMah

on A

ssoc

iate

s\D

ocum

ents

\620

0015

6_O

C B

rew

ster

Villa

ge H

omes

tead

Sui

te_A

rch_

APro

chno

w@

mcm

grp.

com

.rvt

A001

APRIL 19, 2021

AAPMAG

HO

MES

TEAD

BAT

HIN

G S

UIT

E AL

TERA

TIO

N

33

00 W

. BRE

WST

ER S

TREE

T, A

PPLE

TON

, WI 5

4914

BR

EWST

ER V

ILLA

GE

O0002-06-20-00156

TITL

E SH

EET

HOMESTEAD BATHING SUITE ALTERATIONBREWSTER VILLAGE

3300 W. BREWSTER STREET, APPLETON, WI 54914

SHEET INDEX PROJECT LOCATION MAP DESIGN TEAM

ARCHITECTURAL

McMAHON1445 McMAHON DRIVENEENAH, WI 54956(920) 751-4200PROJECT MANAGER: MARLEY GASTE-MAIL: [email protected]

STRUCTURAL

McMAHON1445 McMAHON DRIVENEENAH, WI 54956(920) 751-4200PROJECT MANAGER: DAN BRELLENE-MAIL: [email protected]

HVAC

McMAHON1445 McMAHON DRIVENEENAH, WI 54956(920) 751-4200PROJECT MANAGER: JOEL CLARYE-MAIL: [email protected] PLUMBING

McMAHON1445 McMAHON DRIVENEENAH, WI 54956(920) 751-4200PROJECT MANAGER: ED ERICKSONE-MAIL: [email protected]

ELECTRICAL

McMAHON1445 McMAHON DRIVENEENAH, WI 54956(920) 751-4200PROJECT MANAGER: JILL FITZSIMONSE-MAIL: [email protected]

PROJECT LOCATION

SHEET NO. SHEET DESCRIPTION

GENERALA001 TITLE SHEET X XA011 FIRST FLOOR LIFE SAFETY PLAN X XA012 SECOND FLOOR LIFE SAFETY PLAN X X

ARCHITECTURALA211 WALL KEY AND PLANS X XA411 INTERIOR ELEVATIONS AND DETAILS X X

PLUMBINGP001 PLUMBING GENERAL NOTES, SYMBOLS & ABBREVIATIONS X XP200 PLUMBING PLANS X

HVACH001 HVAC GENERAL NOTES, SYMBOLS & ABBREVIATIONS X XH201 OVERALL HVAC PLAN X XH501 HVAC SCHEDULES AND DETAILS X X

ELECTRICALE001 ELECTRICAL SYMBOLS AND ABBREVIATIONS XE201 OVERALL SECOND FLOOR ELECTRICAL PLAN-AREA C XE202 ELECTRICAL PLANS X

IMPORTANT NOTICE: THE DRAWINGS AND THE SPECIFICATIONS TOGETHER REPRESENT THE CONSTRUCTION DOCUMENTS, AND AS SUCH, MUST BE USED TOGETHER AS THE BASIS OF DESIGN. THE CONTRACTOR IS SPECIFICALLY INSTRUCTED NOT TO LIMIT THEIR UNDERSTANDING OF THE SCOPE OF THIS PROJECT BASED UPON THE SPECIFICATIONS INDEX. THE CONTRACTOR IS RESPONSIBLE TO REVIEW ALL INFORMATION IN BOTH THE DRAWINGS AND SPECIFICATIONS, AND IS THEREFORE, REQUIRED TO PROVIDE ALL DEFINED, AND REASONABLY IMPLIED, SCOPE OF WORK NO MATTER WHERE IT APPEARS IN THE CONSTRUCTION DOCUMENTS. IN ADDITION, THE CONTRACTOR IS TO REVIEW ANY FORMALLY PROVIDED MODIFICATIONS, CLARIFICATIONS, ADDENDUMS AND/OR OTHER INFORMATION AND INCORPORATE THAT INFORMATION INTO THE CONTRACTOR'S UNDERSTANDING OF THE SCOPE OF THE PROJECT.

DH

S SU

BMIT

TAL:

FEBR

UAR

Y 24

, 202

1

ISSU

ED F

OR

BID

DIN

G:

APR

IL 1

9, 2

021

NO.

DATE

REVI

SION

XXX

X

MAIN ENTRANCE

BUILT IN 2001 UNDER THE FOLLOWING CODES:

HSS 132 WISCONSIN ADMINISTRATIVE RULES FOR NURSING HOMESDEPT. OF COMMERCE COMMERCIAL BUILDING CODE CHS. 50-64, 69NFPA 101 LIFE SAFETY CODE 1991 EDITION1991 ADA GUIDELINES FOR BUILDING & FACILITIES

ADDRESS: APPLETON, WI

OCCUPANCY GROUP: NURSING HOME (WISC. ADMIN. RULES) HS 132NURSING HOME (NFPA) I DIVISION 2

NUMBER OF LEVELS: 2 LEVELS

CONSTRUCTION TYPE: METAL FRAME PROTECTED - 1 HOUR TYPE 3 (WISC.) (PER NFPA: II(111)(PER WISC. CODE: IIA)

EXISTING SQUARE FOOTAGE SUMMARY:LEVEL 1 113, 462 SFLEVEL 2 53, 434 SF

TOTAL FACILITY 166,896 SF

LEVEL 2 ALTERATION: 193 SF

GENERAL LIFE SAFETY INFORMATION

PROJECT NO.

DATE

DESIGNED DRAWN

SHEET NO.

McM

ahon

pro

vides

this

draw

ing

and

dat

a, r

egar

dles

s of

for

m;

as

inst

rum

ents

of s

ervic

e. A

ll rig

hts

inclu

ding

cop

yrig

hts

are

reta

ined

by

McM

ahon

. The

clie

nt a

nd/o

r re

cipie

nt a

gree

s to

the

fulle

st e

xten

t pe

rmitt

ed b

y la

w to

inde

mni

fy a

nd

hold

McM

ahon

har

mle

ss fo

r any

re

use

of o

r cha

nges

mad

e to

the

orig

inal

dra

wing

or d

ata

with

out

prio

r writ

ten

cons

ent b

y M

cMah

on.

1445

McM

AHO

N D

RIV

E N

EEN

AH, W

I 549

56M

ailin

g: P

.O.B

OX

1025

NEE

NAH

, WI 5

4957

-102

5Te

l: (9

20) 7

51-4

200

Fa

x: (9

20) 7

51-4

284

ww

w.m

cmgr

p.co

m

4/30

/202

1 4:

08:3

3 PM

C:\U

sers

\apr

ochn

ow.M

CM

\One

Driv

e - M

cMah

on A

ssoc

iate

s\D

ocum

ents

\620

0015

6_O

C B

rew

ster

Villa

ge H

omes

tead

Sui

te_A

rch_

APro

chno

w@

mcm

grp.

com

.rvt

A011

APRIL 19, 2021

AAPMAG

HO

MES

TEAD

BAT

HIN

G S

UIT

E AL

TERA

TIO

N

33

00 W

. BRE

WST

ER S

TREE

T, A

PPLE

TON

, WI 5

4914

BR

EWST

ER V

ILLA

GE

O0002-06-20-00156

FIR

ST F

LOO

R L

IFE

SAFE

TY P

LAN

NOT TO SCALEA0111 EXISTING LIFE SAFETY PLAN LEVEL 1

NO.

DATE

REVI

SION

BATHING SUITEPROJECT WORK AREA:

LEVEL 2 ALTERATION193 SF

BUILT IN 2001 UNDER THE FOLLOWING CODES:

HSS 132 WISCONSIN ADMINISTRATIVE RULES FOR NURSING HOMESDEPT. OF COMMERCE COMMERCIAL BUILDING CODE CHS. 50-64, 69NFPA 101 LIFE SAFETY CODE 1991 EDITION1991 ADA GUIDELINES FOR BUILDING & FACILITIES

ADDRESS: APPLETON, WI

OCCUPANCY GROUP: NURSING HOME (WISC. ADMIN. RULES) HS 132NURSING HOME (NFPA) I DIVISION 2

NUMBER OF LEVELS: 2 LEVELS

CONSTRUCTION TYPE: METAL FRAME PROTECTED - 1 HOUR TYPE 3 (WISC.) (PER NFPA: II(111)(PER WISC. CODE: IIA)

EXISTING SQUARE FOOTAGE SUMMARY:LEVEL 1 113, 462 SFLEVEL 2 53, 434 SF

TOTAL FACILITY 166,896 SF

LEVEL 2 ALTERATION: 193 SF

GENERAL LIFE SAFETY INFORMATION

PROJECT NO.

DATE

DESIGNED DRAWN

SHEET NO.

McM

ahon

pro

vides

this

draw

ing

and

dat

a, r

egar

dles

s of

for

m;

as

inst

rum

ents

of s

ervic

e. A

ll rig

hts

inclu

ding

cop

yrig

hts

are

reta

ined

by

McM

ahon

. The

clie

nt a

nd/o

r re

cipie

nt a

gree

s to

the

fulle

st e

xten

t pe

rmitt

ed b

y la

w to

inde

mni

fy a

nd

hold

McM

ahon

har

mle

ss fo

r any

re

use

of o

r cha

nges

mad

e to

the

orig

inal

dra

wing

or d

ata

with

out

prio

r writ

ten

cons

ent b

y M

cMah

on.

1445

McM

AHO

N D

RIV

E N

EEN

AH, W

I 549

56M

ailin

g: P

.O.B

OX

1025

NEE

NAH

, WI 5

4957

-102

5Te

l: (9

20) 7

51-4

200

Fa

x: (9

20) 7

51-4

284

ww

w.m

cmgr

p.co

m

4/30

/202

1 4:

08:3

5 PM

C:\U

sers

\apr

ochn

ow.M

CM

\One

Driv

e - M

cMah

on A

ssoc

iate

s\D

ocum

ents

\620

0015

6_O

C B

rew

ster

Villa

ge H

omes

tead

Sui

te_A

rch_

APro

chno

w@

mcm

grp.

com

.rvt

A012

APRIL 19, 2021

AAPMAG

HO

MES

TEAD

BAT

HIN

G S

UIT

E AL

TERA

TIO

N

33

00 W

. BRE

WST

ER S

TREE

T, A

PPLE

TON

, WI 5

4914

BR

EWST

ER V

ILLA

GE

O0002-06-20-00156

SEC

ON

D FL

OO

R LI

FE S

AFET

Y PL

AN

NOT TO SCALEA0121 EXISTING LIFE SAFETY PLAN LEVEL 2

NO.

DATE

REVI

SION

ACGFI

GFI

3D D

ACGFI

GFID3

GFI

DGF

I

J

ACGFI

F

D

/-

DW

• COORDINATE ALL WALL SWITCH, OUTLET, FIRE ALARM, THERMOSTAT, NURSE CALL, ETC., LOCATIONS WITH OWNER PRIOR TO CONSTRUCTION.

• DO NOT SCALE FROM DRAWINGS. BRING ANY DISCREPANCIES TO THE ARCHITECTS ATTENTION.

• COORDINATE LOCATIONS AND QUANTITY OF WORK WITH MECHANICAL, ELECTRICAL, AND PLUMBING CONTRACTORS.

• ALL DIMENSIONS ARE CLEAR FROM THE FACE OF FINISHED WALL/PARTITION TO FACE OF FINISHED WALL/PARTITION OR FACE OF EXISTING WALLS ACTUAL FACE.

• ALL PIPING, CONDUIT AND RELATED MECHANICAL AND ELECTRICAL ITEMS SHALL BE CONCEALED WITHIN GYPSUM BOARD FURRING AS REQUIRED IN FINISHED AREAS WHETHER SHOWN ON DRAWINGS OR NOT, UNLESS NOTED OTHERWISE.

• PROVIDE METAL PLATE BACKING AND/OR TREATED WOOD BLOCKING IN WALLS WHERE WALL-MOUNTED EQUIPMENT IS SHOWN ON PLANS OR ELEVATIONS. VERIFY HEIGHT AND LENGTH WITH ACTUAL EQUIPMENT.

• SEE SHEET A011 & A012 FOR LIFE SAFETY PLAN AND FIRE PARTITION RATINGS.

• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS BEFORE CONSTRUCTION.

• GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING NEW AND/OR EXISTING OPENINGS AND/OR PENETRATIONS. SEAL ALL NON-RATED OPENINGS AND PENETRATIONS WITH ACOUSTICAL CAULK. SEAL ALL OPENINGS AND PENETRATIONS IN FIRE-RATED ASSEMBLIES PER IBC 714. ALL OF THE ITEMS LISTED UNDER THIS BULLET POINT ARE THE GENERAL CONTRACTOR'S RESPONSIBILITY FOR THE FULL SCOPE OF THIS PROJECT. IT IS THE G.C.'S DECISION WHETHER THESE ITEMS WILL BE SELF-PERFORMED BY THE G.C. OR PERFORMED BY ANOTHER CONTRACTOR UNDER THE G.C.'S CONTRACT.

GENERAL PLAN NOTES (SEE PLAN 2/A211)

COUNTER, LOWER STORAGE

CONTROL

CONTROL

G2CURTAINW/ 22"MESH TOPANDTRACK

A411

A13FOLDINGSHOWERSEAT

A7 SOAPDISPENSER

A8 TOILETTISSUEDISPENSER

A9 PAPERTOWELDISPENSER

NURSECALL

A5 HANDSANITIZER

UPPER STORAGEUC LIGHTING

SOLID SURFACE

G1GLOVES (3SIZES)

G3 TRASH

A11FOLD-DOWNSEAT

A12 30" X36"WOOD-LOOKFRAMEDMIRROR

G4 SOILEDLINEN

4

B1ARJOHUNTLEIGHPARKERTUB

A411 2A411

1

A411

3

B4WARMINGCABINET

UPPER STORAGE

A4SWING-UPGRAB BAR

A1 GRABBAR (18")

A2 GRABBAR (42")

A3 GRABBAR (24")

A3 GRABBAR (24")

A2 GRABBAR (42")

BATH161

FLOOR SINKRUN PLUMBING UNDER FLOOR

NURSECALL

75.00

°

2' - 0"

1' -

1 3/

8"STEEL SUPPORTS IN WING WALLS

NURSECALL

ADJUSTABLE HEIGHT HAIR WASH

A10DOUBLEROBEHOOK(S)

4' - 0"

A6FOLDINGSHOWERSEAT

TRAVERSE CEILING LIFT BEAM

PARTIALLY CONCEALED LIFT TRACKS

CURTAIN TRACKGLAZING CHANNEL

PROVIDE CLEARANCE BETWEEN LIFT TRACK AND CABINET SO THAT CEILING LIFT CASSETTE DOES NOT COME IN CONTACT W/ CABINET

BATH161

RADIANT PANEL - SEE HVAC DRAWINGS

EX. CORR.

EX. CORR.

EX. CORR.

C1C1EX. LAUNDRY

EX. CUST.EX. LIFT

--EX.

--EX.

--EX.

C1C1

C1 C1C1 C1

C2

C2

C2C2

C2

C2 C2 C1

ACT-19' - 0"

ACT-29' - 0"

B2ARJOHUNTLEIGHMAXI SKY600CEILINGLIFT ANDTRACK

C1

EX. LOUNGE

--EX.

--EX.

--EX.

--EX.

C1C1

C1C1

PT-2PT-1

--PT-2

PT-1/EP-2

PT-2

/EP-

1

PT-2

/EP-

1

BATH161

F1

F2

NEW FLOOR DRAIN

EX. CLEAN OUT

EXISTING FLUSH METAL TRANSITION TO REMAIN AS IS. FLOORING CONTRACTOR TO REPLACE AND/OR ADJUST EXISTING METAL TRANSITION IF NECESSARY TO ENSURE A SMOOTH TRANSITION FROM EXISTING CARPET TO NEW FLOOR TILE.

NEW FLOOR SINK LOCATION

PT-1 WALL AND BASE

PT-1 BASE AT CABINET

PT-2 BASE AT CABINETSPT

-1 W

ALL

AND

BAS

E

PT-1 WALL AND BASE

EXTEND EP-2 TO CABINET

6' - 2 7/8" 2' - 6 1/8" 2' - 0" 1' - 6"

5' -

2"4

7/8"

10' -

3 1

/8"

5' - 2"

4 7/8"

6' - 8 1/8"

135.00°

135.00°

2' -

2"

2' - 2"

3 1/2"

MIN.4' - 0"

3 1/2"

2' - 11" 2' - 3" 4 7/8" 6' - 8 1/8"

2' -

11"

2' -

3"4'

- 9"

5' -

11"

0A

0A

0B

0B

1' -

6"

8' - 9" 3' - 6"

EXISTING DOOR AND FRAME TO REMAIN

BL1

BATH161

2

44

5

5

5

6

15' -

10"

12' - 3"

7 7

7

1

3

5

1

58

8

9 9

10

9

EX. LAUNDRY

EX. CUST.EX. LIFT

EXISTING POWER WASHER CONTROL BOARD TO BE REMOVED AND TURNED OVER TO OWNER - SEE PLUMBING DRAWINGS. PATCH WALL FROM DEMOLITION TO MATCH EXISTING CONSTRUCTION. PAINT WALL TO MATCH EXISTING.

11

VERIFY2' - 6"

VER

IFY

12

6" 1' - 6"

1' -

6"6"

13

14

107

15

11

1 FB 1 FB 1 FB 1 FB

1 FB 1 FB 1 FB 1 FB

1 FB

1 FB

1 FB

1 FB

1 FB

1 FB

1 FB

1 FB

1 FB 1 FB

1 FB

1 FB

4

GENERAL FINISH NOTES (SEE PLAN 3/A211)• SEE SPECIFICATIONS FOR SPECIFIC FINISH INFORMATION.

• SEE REFLECTED CEILING PLAN FOR CEILING FINISHES.

• COORDINATE FLOORING WITH PLUMBING FLOOR DRAINS AND ASSOCIATED SLOPES. SEE PLUMBING PLANS FOR LOCATIONS.

• SEE INTERIOR ELEVATIONS ON SHEET A411 FOR ADDITIONAL INFORMATION.

XX-#XX-# TRANSITION BETWEEN FLOORING MATERIALS

FINISH PLAN LEGEND (SEE PLAN 3/A211)

MATERIAL ABBREVIATIONS - SEE ABBREVIATIONS LIST AND SPECIFICATIONS FOR ADDITIONAL INFORMATION

FLOORBASE

WALL

WALL

WAL

L

WAL

L

NOTES

6A

6A

6B

6B

6B

5A

1A

1A

6B

6B 6B

6B

6C

6D

6D

6D

6D

6D

6E

3A

4A1B

1B

1B

1D 1D1B

6B

5B

5B

6E

6E

6E

6E

6E6E 6E

6E

HATCHING INDICATES SCOPE OF CONCRETE FLOOR CUTTING AND PATCHING FOR PLUMBING RELOCATION. CUTTING, PATCHING, AND FLOOR PREP BY GENERAL CONTRACTOR. COORDINATE WITH PLUMBING DRAWINGS. PATCH CONCRETE AND PREP FOR NEW FINISHES. EXISTING SECOND FLOOR STRUCTURE 8" PRECAST CONCRETE WITH 3" CONCRETE TOPPING.

6E

5C

6E

4C

6E

5D

EXISTING FLUSH METAL TRANSITION TO REMAIN AS IS.

1C

1C

DEMOLITION LEGEND:

EXISTING CONSTRUCTION TO REMAIN

EXTENT OF DEMOLITION

• EXISTING BUILDING HAS BEEN SHOWN ACCORDING TO ORIGINAL BUILDING PLANS, FIELD NOTES AND MEASUREMENTS. EXISTING CONDITIONS AND DIMENSIONS SHALL BE FIELD VERIFIED BY CONTRACTORS AND DISCREPANCIES REPORTED TO THE ARCHITECT.

• DASHED LINES INDICATE EXISTING WALLS, FLOORS, DOORS, WINDOWS, CABINETS & FIXTURES TO BE REMOVED.

• EXISTING WALLS, PARTITIONS, FLOOR LINES, DOORS AND FRAMES THAT REMAIN ARE SHOWN IN CONTINUOUS LINE WEIGHT. THESE AND EXISTING FLOOR AND WALL FINISHES THAT ARE SCHEDULED TO REMAIN SHALL BE PROTECTED FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.

• WHERE WALLS OR PARTITIONS ARE INDICATED TO BE REMOVED, REMOVE ENTIRE WALL OR PARTITIONS AS WELL AS DUCTS, PIPING, CONDUITS AND OTHER ELEMENTS IN OR ON THEM WHICH MAY OR MAY NOT BE SPECIFICALLY IDENTIFIED, UNLESS OTHERWISE NOTED. PATCH EXISTING ADJACENT CONSTRUCTION THAT IS TO REMAIN WHERE APPLICABLE.

• THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL DOORS, HARDWARE, FIXTURES AND EQUIPMENT BEING REMOVED DURING DEMOLITION. COORDINATE WITH OWNER ALL EQUIPMENT TO BE SALVAGED AND/OR REUSED ON THE PROJECT.

• EXISTING FINISHES TO BE REMOVED SHALL HAVE THE ORIGINAL SUBSTRATE PREPARED TO RECEIVE NEW FINISHES.

• MAINTAIN AND PROTECT EXISTING UTILITY SERVICES TO REMAIN AND/OR TO BE OPERATIONAL DURING DEMOLITION AND CONSTRUCTION.

• ALL FIELD VERIFICATION FOR PLUMBING, MECHANICAL & ELECTRICAL DEMOLITION IS THE CONTRACTORS RESPONSIBILITY.

• SCOPE OF DEMOLITION AND REMOVAL WORK SHALL NOT BE LIMITED BY THESE DRAWINGS BUT SHALL INCLUDE ANY AND ALL WORK NECESSARY TO FACILITATE NEW CONSTRUCTION.

• GENERAL CONTRACTOR TO PROTECT AREAS ADJACENT TO DEMOLITION DURING CONSTRUCTION.

• GENERAL CONTRACTOR TO PROVIDE DUST CONTROL BETWEEN CONSTRUCTION AREAS AND OCCUPIED AREAS AT ALL TIMES.

• DEMOLITION WORK PERFORMED THAT IS NOT REQUIRED FOR NEW CONSTRUCTION IS TO BE REPLACED AT NO CHARGE TO THE OWNER.

• ALL SHUTDOWNS OF MECHANICAL, SPRINKLER, FIRE ALARM AND/OR ELECTRICAL SYSTEMS SHALL BE COORDINATED WITH OWNER.

• GENERAL CONTRACTOR TO COORDINATE DEMOLITION WORK WITH NEW CONSTRUCTION AS SHOWN ON DRAWINGS. REPORT ANY CONFLICTS TO THE ARCHITECT BEFORE DEMOLITION WORK BEGINS.

• SEQUENCE OF DEMOLITION WORK TO BE COORDINATED WITH NEW CONSTRUCTION.

• SEE OTHER DISCIPLINES' DRAWINGS FOR EXTENT OF ITEMS TO BE REMOVED AND SALVAGED FOR RE-USE.

GENERAL DEMOLITION NOTES (SEE PLAN 1/A211)

• SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR DEVICE/FIXTURE TYPES SIZES, INSTALLATION AND SPECIFICATIONS.

• VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO CEILING INSTALLATION.

• CEILING PLAN SHOWS DESIGN INTENT ONLY, REFER TO SPECIFICATIONS AS WELL AS MECHANICAL AND ELECTRICAL DRAWINGS FOR DEVICES, TYPES AND INSTALLATION. DEVICES SHOWN ON ARCHITECTURAL PLAN AND NOT ON THE ENGINEERING DRAWINGS OR SPECIFICATIONS SHOULD BE BROUGHT TO ARCHITECTS ATTENTION FOR CLARIFICATION.

• ACOUSTICAL CEILING GRID SHALL BE CENTERED IN ROOMS UNLESS NOTED OTHERWISE.

• CEILING HEIGHTS ARE DIMENSIONED FROM FINISH FLOOR LINE TO DESIGN ELEVATION OF FINISHED CEILING UNLESS NOTED OTHERWISE.

• CENTER IN BOTH DIRECTIONS RECESSED LIGHTS, AND ELECTRICAL AND MECHANICAL DEVICES WHEN SHOWN IN CEILING TILE.

• MECHANICAL, PLUMBING AND ELECTRICAL CONTRACTORS SHALL COORDINATE DEVICES REQUIRING ACCESS IN NON ACCESSIBLE CEILING. PROVIDE ACCESS PANELS AS NEEDED (EXAMPLE: MECHANICAL VAV BOXES, PLUMBING CLEANOUTS, ETC...).

• GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING NEW AND/OR EXISTING OPENINGS AND/OR PENETRATIONS WITH ACOUSTIC CAULK. SEAL ALL OPENINGS AND PENETRATIONS IN FIRE-RATED ASSEMBLIES PER IBC SECTION 714. ALL OF THE ITEMS UNDER THIS BULLET POINT ARE THE GENERAL CONTRACTOR'S RESPONSIBILITY FOR THE FULL SCOPE OF THIS PROJECT. IT IS THE G.C.'S DECISION WHETHER THESE ITEMS WILL BE SELF-PERFORMED BY THE G.C. OR PERFORMED BY ANOTHER CONTRACTOR UNDER THE G.C.'S CONTRACT.

CEILING HEIGHTS SHOWN ARE ESTIMATES OF WHAT CAN BE ACCOMPLISHED. MECHANICAL EQUIPMENT MAY NECESSITATE A CHANGE TO THESE HEIGHTS. VERIFY FEASIBLE CEILING HEIGHTS AND DISCUSS NECESSARY CHANGES WITH THE ARCHITECT PRIOR TO INSTALLATION OF SYSTEMS ABOVE CEILING.

GENERAL CEILING PLAN NOTES (SEE PLAN 4/A211 & 7/A211)

CEILING PLAN LEGEND (SEE PLAN 4/A211)--------

CEILING FINISH

CEILING HEIGHT (A.F.F.)

RADIANT PANEL - VERIFY LOCATIONS WITH OWNER PRIOR TO CONSTRUCTION

GYPSUM BOARD CEILING/SOFFIT (GYP) - SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION

ACOUSTICAL CEILING (ACT-1) - SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION

ACOUSTICAL CEILING ACCENT (ACT-2) -ARMSTRONG ULTIMATA HEALTH ZONE CREATE!: DESIGN 051 DRAGONFLIES

HVAC GRILLS - SEE HVAC PLANS

RECESSED DOWNLIGHT FIXTURE

SURFACE MOUNTED LINEAR LIGHT FIXTURE

CEILING DESCRIPTIONS (SEE PLAN 4/A211)

ACT-1 VINYL COVERED GYP., ALUMINUM FRAME

ACT-2 VINYL COVERED GYP. ACCENT PANEL

GYP GYPSUM BOARD (PAINT)

• SEAL ALL NEW INTERIOR WALL PARTITION INTERSECTIONS AT FLOORS, CEILINGS/STRUCTURE, AND OTHER WALLS WITH ACOUSTIC SEALANT (USG ACOUSTICAL CAULKING, NON-HARDENING).

• SEAL ALL NON-RATED WALL PENETRATIONS WITH ACOUSTICAL SEALANT (USG ACOUSTICAL CAULKING, NON-HARDENING).

• PENETRATIONS IN HORIZONTAL FIRE-RESISTANCE-RATED ASSEMBLIES AND FIRE-RESISTANCE-RATED WALL ASSEMBLIES SHALL COMPLY WITH IBC SECTION 714.

• JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE-RATED WALLS, FLOOR OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL, FLOOR OR ROOF IN OR BETWEEN WHICH IT IS INSTALLED. FIRE RESISTANT JOINT SYSTEMS SHALL COMPLY WITH IBC SECTION 715.

• PROVIDE TILE BACKER BOARD AT AREAS SCHEDULED TO RECEIVE CERAMIC TILE.

• PROVIDE 5/8" TYPE "X" GWB (UNLESS NOTED OTHERWISE)

• INSTALL BLOCKING OR BACKER MATERIAL FOR ATTACHMENT/MOUNTING OF WALL HUNG ITEMS OR EQUIPMENT.

• GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING AND CAULKING NEW AND/OR EXISTING OPENINGS AND PENETRATIONS IN WALLS ABOVE DROP CEILINGS WITHIN THE SCOPE OF WORK.

GENERAL WALL NOTES:

FLOOR

METAL STUDS @ 16" O.C.

TYPE 0A

SEE

ELEV

A TIO

NS

VAR

IES

5/8" 3 5/8" 5/8"

MEMBRANEBACKER BOARD

WALL TILE

4 7/8"

METAL STUDS @ 16" 0.C.

TYPE 0B

3 5/8" 5/8"

BACKER BOARD

WALL TILE

4 1/4"

WALL TYPE LEGEND

GYPSUM BOARD

SEE

ELEV

ATIO

NS

SECOND FLOOR

SECTION VIEW

PLAN VIEW

1/41 1/

2"6"

1 1/

2"

9"

1 1/2" 6" 1 1/2"

9"

HSS3 x 3 x 1/4 TOILET SUPPORT POST

1/2" x 9" x 9" BASE PLATE w/ (4) 1/2" DIA. ANCHOR BOLTS, EMBED 4" INTO FLOOR FRAMING - TYP. 2

HSS3 x 3 x 1/4 POST

FLOOR FRAMING

METAL STUD WALL -COORDINATE LOCATION OF TOILET ATTACHMENT SUPPORTS WITH TOILET SUPPLIER

SHADING INDICATES SCOPE OF WORK ON SECOND FLOOR

C5

EXISTING ACCESS PANEL - FIELD VERIFY LOCATION

EX. BATH

C4C4

ANY NEW WORK ABOVE EXISTING CEILING SHALL BE AT A MINIMUM 9'-6" A.F.F. FOR FUTURE WORK.

PLUMBING SCOPE OF WORK TO BE COMPLETED THROUGH THE INDICATED OPENINGS THAT WILL BE FINISHED WITH AN ACCESS PANEL TO MINIMIZE DISTURBANCE TO EXISTING ROOM.

VERIFY ACCESS PANEL LOCATIONS ON SITE WITH OWNER.

C41' -

6"

1' - 6"

2' - 0"

2' -

0"

2' -

0"

2' - 0"

EXISTING 2ND FLOOR STRUCTURE:8" PRECAST CONCRETE WITH 3" CONCRETE TOPPING(1 HR FIRE-RESISTANCE RATING)

*PENETRATIONS THROUGH RATED ASSEMBLIES TO COMPLY WITH IBC SECTION 714

1 FB 1 FB 1 FB 1 FB

1 FB

1 FB

PROJECT NO.

DATE

DESIGNED DRAWN

SHEET NO.

McM

ahon

pro

vides

this

draw

ing

and

dat

a, r

egar

dles

s of

for

m;

as

inst

rum

ents

of s

ervic

e. A

ll rig

hts

inclu

ding

cop

yrig

hts

are

reta

ined

by

McM

ahon

. The

clie

nt a

nd/o

r re

cipie

nt a

gree

s to

the

fulle

st e

xten

t pe

rmitt

ed b

y la

w to

inde

mni

fy a

nd

hold

McM

ahon

har

mle

ss fo

r any

re

use

of o

r cha

nges

mad

e to

the

orig

inal

dra

wing

or d

ata

with

out

prio

r writ

ten

cons

ent b

y M

cMah

on.

1445

McM

AHO

N D

RIV

E N

EEN

AH, W

I 549

56M

ailin

g: P

.O.B

OX

1025

NEE

NAH

, WI 5

4957

-102

5Te

l: (9

20) 7

51-4

200

Fa

x: (9

20) 7

51-4

284

ww

w.m

cmgr

p.co

m

4/30

/202

1 4:

08:4

2 PM

C:\U

sers

\apr

ochn

ow.M

CM

\One

Driv

e - M

cMah

on A

ssoc

iate

s\D

ocum

ents

\620

0015

6_O

C B

rew

ster

Villa

ge H

omes

tead

Sui

te_A

rch_

APro

chno

w@

mcm

grp.

com

.rvt

A211

APRIL 19, 2021

AAPMAG

HO

MES

TEAD

BAT

HIN

G S

UIT

E AL

TERA

TIO

N

33

00 W

. BRE

WST

ER S

TREE

T, A

PPLE

TON

, WI 5

4914

BR

EWST

ER V

ILLA

GE

O0002-06-20-00156

WAL

L K

EY A

ND P

LAN

S

1/2" = 1'-0"A2118 EQUIPMENT PLAN

1/4" = 1'-0"A2114 REFLECTED CEILING PLAN

EQUIPMENT SCHEDULE (SEE PLAN 8/A211)

TYPEMARK DESCRIPTION FURNISHED BY INSTALLED BY

A1 GRAB BAR (18") G.C. G.C.A2 GRAB BAR (42") G.C. G.C.A3 GRAB BAR (24") G.C. G.C.A4 SWING-UP GRAB BAR G.C. G.C.A5 HAND SANITIZER OWNER G.C.A6 FOLDING SHOWER SEAT G.C. G.C.A7 SOAP DISPENSER OWNER G.C.A8 TOILET TISSUE DISPENSER OWNER G.C.A9 PAPER TOWEL DISPENSER OWNER G.C.A10 DOUBLE ROBE HOOK(S) G.C. G.C.A11 FOLD-DOWN SEAT G.C. G.C.A12 30" X 36" WOOD-LOOK FRAMED MIRROR CASEWORK

CONTRACTORG.C.

A13 FOLDING SHOWER SEAT G.C. G.C.B1 ARJOHUNTLEIGH PARKER TUB OWNER OWNERB2 ARJOHUNTLEIGH MAXI SKY 600 CEILING LIFT AND TRACK OWNER OWNERB4 WARMING CABINET OWNER OWNERG1 GLOVES (3 SIZES) OWNER G.C.G2 CURTAIN W/ 22" MESH TOP AND TRACK G.C. G.C.G3 TRASH OWNER OWNERG4 SOILED LINEN OWNER OWNER

1/4" = 1'-0"A2113 FINISH PLAN

1/4" = 1'-0"A2112 DIMENSION PLAN N

ORT

H

NO

RTH

NO

RTH

NO

RTH

1/4" = 1'-0"A2111 DEMOLITION PLAN N

ORT

H

FLOORS3A SITE CLEAR EXISTING TILE FLOORING. PATCH AND PREP FLOOR AS REQUIRED

FOR NEW WORK.

WALLS1A SITE CLEAR EXISTING WALL AS REQUIRED FOR NEW WORK. PREP REMAINING

ADJACENT CONSTRUCTION TO RECEIVE NEW FINISH.1B SITE CLEAR EXISTING WALL TILE AND EXISTING TILE BACKER BOARD AS

REQUIRED FOR NEW WORK. CUT AND REMOVE EXISTING GYPSUM BOARD TOHEIGHT OF NEW TILE AS REQUIRED FOR NEW TILE BACKER BOARD AND TILE.

1C SITE CLEAR EXISTING TILE BACKER BOARD AND EXISTING TILE AS REQUIRED FORNEW TILE BACKER BOARD, WATERPROOF MEMBRANE, AND TILE.

1D SITE CLEAR EXISTING WALL TILE AND EXISTING TILE BACKER BOARD ASREQUIRED FOR NEW TILE BACKER BOARD AND TILE.

CEILINGS4A SITE CLEAR EXISTING CEILING SYSTEM.4C SITE CLEAR EXISTING ACCESS PANEL.

TOILET ROOMS5A SITE CLEAR EXISTING TOILET. PATCH AND PREP SURFACES AS REQUIRED FOR

NEW WORK. SEE PLUMBING DRAWINGS.5B SITE CLEAR EXISTING PLUMBING FIXTURE. PATCH AND PREP SURFACES AS

REQUIRED FOR NEW WORK. SEE PLUMBING DRAWINGS.5C SITE CLEAR EXISTING FLOOR DRAIN. RECONFIGURE FLOOR SLOPE FOR NEW

TRENCH DRAIN. SEE PLUMBING DRAWINGS AND COORDINATE FINAL FLOORSLOPE WITH PLUMBING CONTRACTOR.

5D SITE CLEAR EXISTING FLOOR SINK. RECONFIGURE FLOOR SLOPE FOR NEWFLOOR SINK. SEE PLUMBING DRAWINGS AND COORDINATE FINAL FLOOR SLOPEWITH PLUMBING CONTRACTOR.

MISC.6A SITE CLEAR EXISTING CASEWORK. PATCH AND PREP WALL AS REQUIRED FOR

NEW WORK.6B REMOVE EXISTING GRAB BAR AND TURN OVER TO OWNER.6C REMOVE EXISTING HAIRWASH SINK AND TURN OVER TO OWNER. PATCH AND

PREP SURFACES AS REQUIRED FOR NEW WORK.6D REMOVE EXISTING LIGHT FIXTURE AND TURN OVER TO OWNER. PATCH AND

PREP SURFACES AS REQUIRED FOR NEW WORK. SEE ELECTRICAL DRAWINGS.6E REMOVE EXISTING WALL-MOUNTED EQUIPMENT AND TURN OVER TO OWNER.

PATCH AND PREP SURFACES AS REQUIRED FOR NEW WORK.

PL-1 PLASTIC LAMINATE: FORMICA LAMINATE. COLOR: CASCARA TEAKWOOD 8909.SS-1 SOLID SURFACE: FORMICA SOLID SURFACING. COLOR: DRIFT TRAVERTINE 787.LAMINATES/SOLID SURFACES

PT-2 PORCELAIN TILE: DALTILE: REMINISCENT. COLOR: AGED BEIGE RM21. SIZE: 12X24.PT-1 PORCELAIN TILE: DALTILE: VOLUME 1.0. COLOR: ACCENT BROWN VL78. SIZE: 12X24.EP-2 PAINT: EPOXY PAINT: SHERWIN-WILLIAMS. COLOR: RAIN SW 6219EP-1 PAINT: EPOXY PAINT: SHERWIN-WILLIAMS. COLOR: CITY LOFT SW 7631WALLS

PT-2 PORCELAIN TILE BASE: DALTILE: REMINISCENT. COLOR: AGED BEIGE RM21.PT-1 PORCELAIN TILE: DALTILE: VOLUME 1.0. COLOR: ACCENT BROWN VL78.

BASE

PT-1 PORCELAIN TILE: DALTILE: VOLUME 1.0. COLOR: ACCENT BROWN VL78. SIZE: 12X24.FLOORING

ROOM FINISH ABBREVIATIONS (SEE PLAN 3/A211)DEMOLITION NOTESX

PLAN KEYNOTES (SEE PLAN 2/A211)X

1 ALTER SLOPE OF EXISTING CONCRETE FLOOR TO NEW FLOORDRAIN. COORDINATE WITH PLUMBING CONTRACTOR PRIOR TOCONSTRUCTION.

2 EXISTING CLEAN OUT. SEE PLUMBING DRAWINGS.3 NEW LOCATION FOR FLOOR SINK. SEE PLUMBING DRAWINGS.4 PATCH EXISTING FLOOR FROM PLUMBING FIXTURE REMOVAL.

EXISTING FLOOR STRUCTURE 8" PRECAST CONCRETE W/ 3"CONCRETE TOPPING. SEE LIFE SAFETY PLANS FOR FIRE RATINGINFORMATION. PREP SURFACE AS REQUIRED FOR NEW WORK.

5 PATCH WALL FROM DEMOLITION AS REQUIRED TO MATCHEXISTING CONSTRUCTION. PREP AS REQUIRED FOR NEW FINISHES.

6 EXISTING WALL IS FIRE-RATED. PATCHING REQUIRED FROMDEMOLITION AND FOR NEW WORK TO MAINTAIN RATING.

7 GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING NEWAND/OR EXISTING OPENINGS AND/OR PENETRATIONS AND SEALALL NON-RATED OPENINGS AND PENETRATIONS WITH ACOUSTICALCAULK. OPENINGS AND PENETRATIONS IN THE CORRIDOR WALLSMUST BE PATCHED AND SEALED TO RESIST THE PASSAGE OFSMOKE. SEAL ALL OPENINGS AND PENETRATIONS IN FIRE-RATEDASSEMBLIES PER IBC 714.

8 NEW TILE BACKER BOARD AND WATERPROOF MEMBRANE.9 NEW TILE BACKER BOARD.10 NEW TILE BACKER BOARD AND GYPSUM BOARD. INFILL GYPSUM

BOARD TO MATCH EXISTING.11 NEW WATERPROOF MEMBRANE THROUGHOUT ROOM. EXTEND UP

WALL AS RECOMMENDED PER THE MANUFACTURER.12 HSS2 x 2 x 1/4 HORIZ. STRUT, CONNECT TO POSTS W/ BRACKET

PLATES AND 1/4" FILLET WELD ALL AROUND. PROVIDE ADDITIONALFACE PLATES AS NEEDED FOR TOILET ATTACHMENT. COORDINATEHEIGHT W/ TOILET SUPPLIER.

13 HSS 3 x 3 x 1/4 POST w/ 1/2" x 3 1/2" x 9" BASE PLATE AND (2) 1/2"DIAMETER ANCHOR BOLTS EMBEDDED 4" INTO FLOOR FRAMING(TYPICAL 4 POSTS). SEE DETAIL 6/A211 THIS SHEET.

14 HSS 3 1/2 x 1 1/2 x 1/4 (FLAT ORIENTATION) HORIZONTAL STRUTABOVE POSTS, w/ 1/4" FILLET WELDS ALL AROUND, w/ 1/4" THICKEND PLATES (TYPICAL 2 STRUTS).

15 STEEL POST, TYP. (2) - SEE DETAIL 6/A211 THIS SHEET.

FINISH PLAN KEYNOTES (SEE PLAN 3/A211)

X

CEILING PLAN KEYNOTES (SEE PLAN 4/A211 & 7/A211)X

C1 REMOVE CEILING TILES AND GRID AS NECESSARY TO COMPLETE SCOPE OF MECHANICAL, ELECTRICAL,AND PLUMBING SCOPE OF WORK; STORE AND PROTECT MATERIALS FOR REUSE. REINSTALL CEILINGTILE AND GRID WHEN WORK IS COMPLETE. PROVIDE NEW ACCESS PANELS AT HARD CEILINGS THATNEED TO BE CUT FOR NEW WORK AND/OR CUT OPENINGS IN HARD CEILINGS IF NECESSARY TOCOMPLETE WORK, THEN PATCH AND PAINT WHEN WORK IS COMPLETE.. COORDINATE LOCATIONS WITHOWNER. VERIFY CEILING HEIGHTS PRIOR TO CONSTRUCTION.

C2 EXISTING WALL IS FIRE-RATED. PATCHING REQUIRED FROM DEMOLITION AND FOR NEW WORK TOMAINTAIN RATING.

C4 CUT IN NEW OPENING TO COMPLETE PLUMBING SCOPE OF WORK, SEE PLUMBING DRAWINGS. FINISHWITH NEW ACCESS PANEL, PAINT TO MATCH EXISTING CEILING IN COLOR AND FINISH.

C5 CUT AND PATCH EXISTING WALL ABOVE CEILING FOR PLUMBING SCOPE OF WORK.

1" = 160'-0"KEY PLAN N

ORT

H

F1 PAINT EXISTING DOOR FRAME. PREP AS REQUIRED. VERIFY COLOR WITHARCHITECT.

F2 EXISTING CARPET TO REMAIN.

1 1/2" = 1'-0"A2116 POST CONNECTION

1/4" = 1'-0"A2117 EXISTING FIRST FLOOR RCP

NO.

DATE

REVI

SION

CL CL CL

ACCESSORY / FIXTURE MOUNTING HEIGHTS & CLEARANCESSCALE: 1/4" = 1'-0"

TYPICAL REACH DETAILS

UNOBSTRUCTED FOWARD REACH

CO

NTR

OLS

VENDING

TOWELS

UNOBSTRUCTEDSIDE REACH

CO

NTR

OLS

TOWELS

VENDING

MIN

.

15

"M

AX.

48

"

RESTROOM PLAQUE DETAILS

H.C. SIGNAGE TO BE MOUNTED 9" FROM STRIKE FACE OF JAMB TO CENTER OF SIGN

5'-0

" A.F

.F. T

OC

ENTE

R O

F SI

GN

LADIES MEN DOT HEIGHT MIN. 0.025" MAX. 0.037"

6" M

IN.

8" H.C. SIGNAGE W/ BRAILLE - MOUNT60" A.F.F. TO CENTER OF SIGN (MAX.)

9"

FRONT ELEVATION SIDE ELEVATIONACCESSIBLE TANK

WATER CLOSETACCESSIBLE TANK

WATER CLOSET

CL

42" MAX

MIN

.

18

"

33"

-36"

39"

-41"

MIN

.

18

"MAX.

12" 42"

39"-41" 1

6"-1

8"

60

" 56"

33"

-36"

16"-18"

36" MIN.

12" 24"MIN. MIN.

(FIXTURES SHOWN ABOVE ARE FOR DESIGN INTENT ONLY - SEE PLANS & SPECIFICATIONS FOR EXACT FIXTURES)

A3A1

A2

SIDE ELEVATION FRONT ELEVATION

17"-1

9"

LAVATORY

34"

MA

X.

40"

MA

X.

REF

LEC

TIN

G

SUR

FAC

E

30"

48

"

15" 15"

A12

TOILET ROOM ACCESSORIES

48"

MA

X.

48"

MA

X.

FIRE EXTINGUISHERS

27"

MIN

.

48"

MA

X.

WHEELCHAIR ACCESSIBLE

DRINKING FOUNTAIN

36"

MA

X.

38"

MIN

.

43" M

AX.

SIDEAPPROACH

FRONTAPPROACH

30"

48

"

15" 15"

19

"

48"

30

" 24" 24"

STANDING

CL

16"

-18"

60

"

59"

WALL HUNG FLOOR MOUNTED/ CHILDREN

ALTERNATE ROLL-IN SHOWER

36

"

MIN.60"

END WALL ELEVATION

24"-36"MIN.36"

SEATMAX.1 1/2"

MAX

.2

1/2"

15"-1

6"

MAX.3"

MAX.6"

MAX.6"

MAX

.6"

CONTROL WALL

SEAT WALL

33" -

36"

MAX.27"

MIN

.38

"M

AX.

48"

17"-1

9"

48" MIN.

36" M

IN.

36

"

36"18"

MAX

.4"

MAX.2 1/2"

MAX

.3"

15"-16" 22"-23"

SEAT

14"-1

5"

MAX

.1

1/2"

SEAT

WAL

L CONTROL WALL

TRANSFER SHOWER

CONTROL WALL ELEVATION

38" M

IN.

48" M

AX.

MAX.15"

MIN

.30

"M

IN.

30"

MIN.60"

MAX.6"

MAX

.6"

SEAT

GR

A B B

ARAB

OVE

48" M

AX.

MIN.16"

27" MAX.

SEAT

WAL

L

CONTROL WALL

STANDARD ROLL-IN SHOWER

CONTROL WALL ELEVATION

MAX.2 1/2"

MAX

.1

1/2"

MAX

.3"

A8

A7 A9

GENERAL INTERIOR NOTES• PROVIDE TOILET ACCESSORIES PER SPECIFICATIONS OR

APPROVED EQUAL. INSTALL ACCORDING TO MANUF. SPECIFICATIONS.

• ALL BLOCKING REQUIRED FOR SUPPORT OF GRAB BARS AND ACCESSORIES SHALL BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR.

• SEE ELEVATIONS FOR TYPICAL FIXTURE AND ACCESSORY MOUNTING HEIGHTS.

• FIELD VERIFY ALL DIMENSIONS PRIOR TO CASEWORK CONSTRUCTION.

• PROVIDE OFFSET TRAP AND HW, CW, DRAIN INSULATION KIT AT ALL OPEN SINKS.

5A411

6A411

7A411

11"

2' -

10"

3' - 10" 1' - 6"

1/2"

1' - 8"

1' - 8 1/2" 2' - 0" 1' - 6"

1' -

0"4'

- 3"

3' -

9"

CUBICLE CURTAINGLASS PARTITION W/ FILM - CAULK AT COUNTERWALL SCONCE, TYP.MIRROR - SEE DETAIL 16/A411

HAND SANITIZERTRASH AND SOILED LINEN

PL. LAM. APRON AND SLOPED PL. LAM. PANEL AND SOLID SURFACE COUNTER

24" DEEP PL. LAM. CABINET W/ OPEN ADJ. SHELVING

WARMING CABINET

19" DEEP PL. LAM. CABINET W/ DRAWERS AND PULL-OUT SHELVES - EXTRA HEAVY-DUTY SLIDES

PL. LAM. FILLER

(3) OPENINGS FOR GLOVES -COORDINATE OPENING W/ OWNER GLOVE HOLDER - SEE DETAIL 15/A411

PL. LAM. SOFFIT

SOAP AND PAPER TOWEL

SOLID SURFACE SINK

HORIZONTAL GRAB BAR

SWING-UP GRAB BAR

3' -

9"

3' - 4" 2"

1' -

2"3'

- 4"

1' -

6"3'

- 0"

2' - 0" 12' - 10" 1' - 0"

PAPER TOWELSOAPWALL SCONCE

TRAVERSE CEILING TRACK

12" DEEP CABINET W/ ADJ. SHELVING

TUB

TOILET TISSUE DISPENSER

HORIZONTAL GRAB BAR

VERTICAL GRAB BAR

NURSE CALL

5' -

9"NURSE CALL

14A411

10A411

8A411

9A411

2' - 4"2 5/8"

3' -

0"1'

- 6"

3' -

4"6"

8"

12" DEEP PL. LAM. BASE CABINET W/ DRAWERS, LOCKING, EXTRA HEAVY DUTY DRAWER SLIDES

12" DEEP PL. LAM. CABINETS W/ ADJ. SHELVING AND 3" APRON FOR TASK LIGHTING

2 5/8" 2' - 4"

6 7/8" 1' - 0"

2' - 4"

2 5/8"

5' - 6 7/8"

12" DEEP SOLID SURFACE COUNTERPL. LAM. PANEL

12" DEEP PL. LAM. BASE CABINET W/ ADJ. SHELVING

FOLDING BENCH

8" DEEP SOLID SURFACE COUNTER

PL. LAM. FILLER, TYP. EACH SIDE

PL. LAM. FILLER

EXTEND CABINET AND SHELVES BEHIND PL. LAM. PANEL

GROMMET FOR TUB POWER CORD

REMOVABLE PL. LAM. PANEL FOR ELECTRICAL AND PLUMBING ACCESS

7' -

10"

1' -

2"

PL. SOFFIT - HOLD DOWN FOR TRAVERSE BEAM

THERMOSTATS

SECOND FLOOR100' - 0"

2' -

10"

8" MIN.

1 1/

2"5

1/2"

MIN

.

2' -

3"

6" MAX.

SOLID SURFACE COUNTER W/ SOLID SURFACE SINK

EASE ALL EDGES

PLASTIC LAMINATE OVER 3/4" PARTICLE BOARD

2' - 1"

REMOVABLE PL. LAM. PANEL - SCREW FASTEN W/ THREADED INSERTS

NOTE: VERIFY LAVATORY AND PIPE CLEARANCES

1"

MIN

.

9"

SECOND FLOOR100' - 0"

2' -

10"

4"10

3/4

"1'

- 5

3/4"

1 1/

2"

SOLID SURFACE COUNTER

PLASTIC LAMINATE ON ALL EXPOSED SURFACES

ADJ. SHELF HOLES

PLASTIC LAMINATE ADJ. SHELF

SEE ELEV.

1"

1x BLOCKING

TILE BASE - WRAP AROUND EXPOSED FACES

EASE ALL EDGES

A41117

SECOND FLOOR100' - 0"

1' -

0"4'

- 3"

3' -

9"

9' -

0"

PLASTIC LAMINATE OVER 3/4" PARTICLE BOARD

PL. LAM. PULL-OUT SHELF

MELAMINE CABINET LINER ON ALL SEMI-EXPOSED SURFACES

PLASTIC LAMINATE PANELING

SEE WALL TYPE LEGEND FOR DETAILS

1' - 6"CABINET AND CABINET DOOR TO OVERLAP WALL TILE - FIELD VERIFY

STEEL SUPPORT - SEE DETAIL

1/2"

1/2"

1' -

0"11

"11

"6'

- 2"

TYP.8"

TYP.3"

SECOND FLOOR100' - 0"

8"3'

- 0

1/2"

3 1/

2"1'

- 6"

2' -

8"4"

8"8'

- 4"

SOLID SURFACE COUNTER

EASE ALL EDGES

PLASTIC LAMINATE OVER 3/4" PARTICLE BOARD

ADJ. SHELF, TYP.ADJ. SHELF HOLES

MELAMINE CABINET LINER ON SEMI-EXPOSED SURFACES

PLASTIC LAMINATE OVER 3/4" PARTICLE BOARD

ADJ. SHELF HOLES

ADJ. SHELF, TYP.

1X BLOCKINGTILE BASE

MELAMINE CABINET LINER ON SEMI-EXPOSED SURFACES

CEILING LIFT TRAVERSE BEAM

FIXTURE BY ELEC. CONTRACTOR. ALLOW FOR CONTINUOUS RUN OF U.C. LIGHTING

HOLD DOWN PANEL FOR CEILING LIFT TRAVERSE BEAM TO CLEAR - VERIFY DIMENSION WITH EQUIPMENT MANUFACTURER

1' - 0"

6"3'

- 0

1/2"

SECOND FLOOR100' - 0"

3' -

0"

1' - 0"

4"2'

- 6

1/2"

1 1/

2"

SOLID SURFACE COUNTER

EASE ALL EDGES

PLASTIC LAMINATE OVER 3/4" PARTICLE BOARD

MELAMINE CABINET LINER ON SEMI-EXPOSED SURFACES

1x BLOCKING

TILE BASE

DRAWER PARTITION, TYP., EACH DRAWER TO HAVE (4) COMPARTMENTS

EQ.

8"2"

EQ.

8"2"

EQ.

8"

FRAME ELEVATIONS

BL1ALUMINUM

1/2" TEMP. SAFETY GLASSGRAPHIC FILM APPLIED

8' -

8"4"

2' - 0"

12A411

13A411

9' -

0"

SECOND FLOOR100' - 0"

1/2" TEMP. SAFETY GLASS W/ APPLIED GRAPHIC FILM

4" ALUMINUM CHANNELSEALANT BOTH SIDES

1"

1/2" TEMP. SAFETY GLASS W/ APPLIED GRAPHIC FILM

GASKET - BOTH SIDES

ALUMINUM GLAZING CHANNEL TRIM

LAY-IN CEILING TILES

2"

METAL STUD SUPPORT TO STRUCTURE ABOVE

3' -

0"

1" 4 7/8" 2 1/8"

8"

SOLID SURFACE COUNTER

EASE ALL EDGES

1 1/

2"

SEE WALL TYPE LEGEND FOR DETAILS

WATERPROOF MEMBRANE TO WRAP TOP OF WALL FOR CONTINOUS WATER PROTECTION

WATERPROOF MEMBRANE TO CONTINUE ON FLOOR SUBSTRATE

8"1'

- 6"

8"

0' - 1

"

RADIUS ALL CORNERS

OPENING IN CABINET FOR POWER W/ EDGE BANDING TO MATCH PLASTIC LAMINATE

FLOOR

CENTER OPENING IN CABINET

SECOND FLOOR100' - 0"

2' -

8"4"

3' -

0"

REMOVABLE PANEL FOR ELECTRICAL AND PLUMBING ACCESS

BACK OF CABINET OPEN AT EXISTING PLUMBING LINES AND ELECTRICAL RECEPTACLE - VERIFY LOCATION AND DIMENSIONS

OPEN FOR PLUMBING TO RUN UP AND CONNECT TO EXISTING LINES AT EX. WALL - VERIFY LOCATION AND DIMENSION W/ PLUMBING CONTRACTOR

GROMMET FOR POWER CORD FOR TUB TO RUN TO RECEPTACLE - FINISH W/ EDGE BANDING TO MATCH PL. LAM. - VERIFY DIAM. W/ ELECTRICAL CONTRACTOR

1' - 0"

SEE 8/A411

• VERIFY ALL EQUIPMENT WITH OWNER PRIOR TO CONSTRUCTION.

• COORDINATE GROMMET LOCATIONS WITH OWNER PRIOR TO INSTALLATION

• 1-INCH RADIUS FOR ALL OUTSIDE CORNERS OF COUNTERTOPS.

• VERIFY ALL ROOM DIMENSIONS PRIOR TO CONSTRUCTION OF CASEWORK.

• GENERAL CONTRACTOR TO PROVIDE ALL NECESSARY BACKING IN WALLS.

• SUPPLY AND INSTALL SUPPORT BRACKETS AS NEEDED UNDER COUNTERTOPS.

• MINIMUM 1" FILLER WHERE CABINET IS 90 DEGREES TO WALL OR OTHER CABINETS

• ALL VISABLE CASEWORK SURFACES TO BE PLASTIC LAMINATE.

• PROVIDE DOUBLE PLY FOR EACH ADJUSTABLE SHELF GREATER THAN 2'-6" IN WIDTH.

GENERAL CASEWORK NOTES

BACKING TO SUPPORT 500 LBS. MINIMUM - STRUCTURAL ENGINEERING/DESIGN BY G.C.

MOUNTING FLANGE - FASTEN PER MANUFACTURER'S RECOMMENDATION

GUIDE BRACKET AND BASEPLATE -FASTEN PER MANUFACTURER'S RECOMMENDATION

APPLY SILICONE TO SEAL, TYP.

FILL WITH SILICONE AND APPLY SILICONE AROUND ALL FASTENERS TO MAINTAIN WATERPROOFING. TYPICAL AT WALL-MOUNTED ACCESSORIES

5' -

9"

2' -

10"

FOLD-DOWN SEAT

WALL SCONCE

8" DEEP SOLID SURFACE COUNTER

1' - 0" 8' - 11" 3' - 10" 2' - 1"

GLASS PARTITION W/ APPLIED GRAPHIC FILM

(2) DOUBLE ROBE HOOKS

FOLD-DOWN SEAT

REMOVABLE PL. LAM. PANEL COORDINATE PLUMBING WITH CASEWORK

GLAZING CHANNEL

5' - 2"

NURSE CALL

HAIRWASH SINK - SEE PLUMBING DRAWINGS FOR MORE INFORMATION

HATCHING INDICATES WALL BACKING

EQ.

TYP.

5 5/16" EQ.

TYP.

2 3/

4"

1' -

3"4

9/16

"4

9/16

"

(3) SIZES GLOVE BOX DISPENSER BY OWNER MOUNTED TO INTERIOR OF CABINET DOOR

COORDINATE OPENINGS W/ OWNER GLOVE HOLDER

PVC AROUND CABINET OPENING TO MATCH PL. LAM. - TYP.

CENTER OF CABINET

UPPER CABINET - SEE ELEVATIONS

EQ. EQ.

SECOND FLOOR100' - 0"

2"2'

- 8"

2"3'

- 2"

2' -

10"

MAX

.

3' -

4"

2" 2' - 2" 2"

2' - 6"

PLASTIC LAMINATE FRAME TO MATCH CASEWORK - ALL EXPOSED FACES TO BE PL. LAM.

MITER CORNERS, TYP.

PROVIDE MOUNTING HARDWARE TO MITIGATE TILE OFFSET

PROJECT NO.

DATE

DESIGNED DRAWN

SHEET NO.

McM

ahon

pro

vides

this

draw

ing

and

dat

a, r

egar

dles

s of

for

m;

as

inst

rum

ents

of s

ervic

e. A

ll rig

hts

inclu

ding

cop

yrig

hts

are

reta

ined

by

McM

ahon

. The

clie

nt a

nd/o

r re

cipie

nt a

gree

s to

the

fulle

st e

xten

t pe

rmitt

ed b

y la

w to

inde

mni

fy a

nd

hold

McM

ahon

har

mle

ss fo

r any

re

use

of o

r cha

nges

mad

e to

the

orig

inal

dra

wing

or d

ata

with

out

prio

r writ

ten

cons

ent b

y M

cMah

on.

1445

McM

AHO

N D

RIV

E N

EEN

AH, W

I 549

56M

ailin

g: P

.O.B

OX

1025

NEE

NAH

, WI 5

4957

-102

5Te

l: (9

20) 7

51-4

200

Fa

x: (9

20) 7

51-4

284

ww

w.m

cmgr

p.co

m

4/30

/202

1 4:

08:4

6 PM

C:\U

sers

\apr

ochn

ow.M

CM

\One

Driv

e - M

cMah

on A

ssoc

iate

s\D

ocum

ents

\620

0015

6_O

C B

rew

ster

Villa

ge H

omes

tead

Sui

te_A

rch_

APro

chno

w@

mcm

grp.

com

.rvt

A411

APRIL 19, 2021

AAPMAG

HO

MES

TEAD

BAT

HIN

G S

UIT

E AL

TERA

TIO

N

33

00 W

. BRE

WST

ER S

TREE

T, A

PPLE

TON

, WI 5

4914

BR

EWST

ER V

ILLA

GE

O0002-06-20-00156

INTE

RIO

R E

LEVA

TIO

NS

AND

DET

AILS

TOILET ROOM ACCESSORY SCHEDULEMARK DESCRIPTION FURNISHED BY INSTALLED BY DESIGN BASISA1 GRAB BAR (18") G.C. G.C. BRADLEY; MODEL 832A2 GRAB BAR (42") G.C. G.C. BRADLEY; MODEL 832A3 GRAB BAR (24") G.C. G.C. BRADLEY; MODEL 832A4 SWING-UP GRAB BAR G.C. G.C. BRADLEY; MODEL 8370-107A5 HAND SANITIZER OWNER G.C. OWNER FURNISHEDA6 FOLDING SHOWER SEAT G.C. G.C. BOBRICK; MODEL B-5181A7 SOAP DISPENSER OWNER G.C. OWNER FURNISHEDA8 TOILET TISSUE DISPENSER OWNER G.C. OWNER FURNISHEDA9 PAPER TOWEL DISPENSER OWNER G.C. OWNER FURNISHEDA10 DOUBLE ROBE HOOK(S) G.C. G.C. BRADLEY; MODEL 9124A11 FOLD-DOWN SEAT G.C. G.C. BRADLEY; MODEL 9562A12 30" X 36" WOOD-LOOK FRAMED MIRROR CASEWORK

CONTRACTORG.C.

A13 FOLDING SHOWER SEAT G.C. G.C. BOBRICK; MODEL B-5192

1/4" = 1'-0"A4111 NORTH ELEVATION

1/4" = 1'-0"A4112 EAST ELEVATION

1/4" = 1'-0"A4113 SOUTH ELEVATION

1" = 1'-0"A4115 SINK DETAIL

1" = 1'-0"A4116 CABINET DETAIL

1" = 1'-0"A4117 CABINET DETAIL

1" = 1'-0"A4118 CABINET DETAIL

1" = 1'-0"A41110 CABINET DETAIL

1 1/2" = 1'-0"A41113 BORROWED LITE DETAIL

1 1/2" = 1'-0"A41112 BORROWED LITE HEAD

1" = 1'-0"A41114 SHOWER WALL

1 1/2" = 1'-0"A41117 TYP. CASEWORK OPENING

1" = 1'-0"A4119 CABINET DETAIL

1 1/2" = 1'-0"A41111 TYP. WALL MOUNT DETAIL

1/4" = 1'-0"A4114 WEST ELEVATION

1 1/2" = 1'-0"A41115 GLOVE BOX

1/2" = 1'-0"A41116 MIRROR ELEVATION

NO.

DATE

REVI

SION

McM

ahon

Ass

ocia

tes,

Inc.

pro

vides

this

draw

ing

and

dat

a, r

egar

dles

s of

for

m;

as

inst

rum

ents

of s

ervic

e. A

ll rig

hts

inclu

ding

co

pyrig

hts

are

reta

ined

by

McM

ahon

As

socia

tes,

Inc.

The

clie

nt a

nd/o

r rec

ipie

nt

agre

es to

the

fulle

st e

xten

t per

mitt

ed b

y la

w to

inde

mni

fy a

nd h

old

McM

ahon

As

socia

tes,

Inc.

har

mle

ss fo

r any

reus

e of

or

cha

nges

mad

e to

the

orig

inal

dra

win

g or

da

ta w

ithou

t prio

r writ

ten

cons

ent b

y M

cMah

on A

ssoc

iate

s, In

c.

H001

NO.

DATE

REVI

SION

McM

ahon

Ass

ocia

tes,

Inc.

pro

vides

this

draw

ing

and

dat

a, r

egar

dles

s of

for

m;

as

inst

rum

ents

of s

ervic

e. A

ll rig

hts

inclu

ding

co

pyrig

hts

are

reta

ined

by

McM

ahon

As

socia

tes,

Inc.

The

clie

nt a

nd/o

r rec

ipie

nt

agre

es to

the

fulle

st e

xten

t per

mitt

ed b

y la

w to

inde

mni

fy a

nd h

old

McM

ahon

As

socia

tes,

Inc.

har

mle

ss fo

r any

reus

e of

or

cha

nges

mad

e to

the

orig

inal

dra

win

g or

da

ta w

ithou

t prio

r writ

ten

cons

ent b

y M

cMah

on A

ssoc

iate

s, In

c.

H201

NORTH NORTH

NO.

DATE

REVI

SION

McM

ahon

Ass

ocia

tes,

Inc.

pro

vides

this

draw

ing

and

dat

a, r

egar

dles

s of

for

m;

as

inst

rum

ents

of s

ervic

e. A

ll rig

hts

inclu

ding

co

pyrig

hts

are

reta

ined

by

McM

ahon

As

socia

tes,

Inc.

The

clie

nt a

nd/o

r rec

ipie

nt

agre

es to

the

fulle

st e

xten

t per

mitt

ed b

y la

w to

inde

mni

fy a

nd h

old

McM

ahon

As

socia

tes,

Inc.

har

mle

ss fo

r any

reus

e of

or

cha

nges

mad

e to

the

orig

inal

dra

win

g or

da

ta w

ithou

t prio

r writ

ten

cons

ent b

y M

cMah

on A

ssoc

iate

s, In

c.

H501

NO.

DATE

REVI

SION