JOB NO. : DATE : REVIEW BY : Seismic Design for Buckling-Restrained Braced Frames Based on AISC 360-05 & AISC 341-05
DESIGN CRITERIA1. Bracing member self shall be composed of a structural steel core & a system that restrains the steel core from buckling.
The each end of brace to gusset plate may be standard bolted connections, modified bolted connections, or true pinconnections. Selecting bracing members are based on the tested & approved manufacture's lists.
2. The lateral capacity of BRBF, selected bracing members with steel beams and columns, must also be checked by a special
3.
based on geometry and can check the gusset interface weld capacities with moment loads.
INPUT DATA & DESIGN SUMMARY
BRACE CORE AXIAL YIELD STRENGTH 150 kips, SD(from tested & approved manufacture's lists, AISC 341-05, 16.2a)
ANGLE BETWEEN BRACE & COLUMN 25 0
GUSSET DIMENSIONS 24.0 in10.1 in
COLUMN SECTION = > W12X96ORIENTATION = x-x 6.35 in
BEAM SECTION = > W16X67ORIENTATION = x-x 8.15 in
THE CONNECTION DESIGN IS ADEQUATE.( 1" Gusset Plate with 7/16" Fillet Weld, 2 leg x 24" at Column Interface, 2 leg x 11" at Beam Interface. )
ANALYSISDETERMINE REQUIRED STRENGTH OF BRACING CONNECTION (AISC 341-05, 16.3a & 16.2d)
247.1 kips, ASDWhere 1.20 , (AISC 341-05, 16.2d. May be verified by nonlinear time-history or analyses.)
1.44 , (AISC 341-05, 16.2d. May be verified by nonlinear time-history or analyses.)
1.30 , (AISC 341-05, Table I-6-1)
DETERMINE BEST FILLET WELD SIZE PER THICKNESS OF GUSSET & FLANGES (AISC 360-05 J2.2b)
w = 7/16 in0.25 in
0.5625 in [Satisfactory]
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE
1 in 1 in )
DETERMINE CONNECTION INTERFACE FORCES ( AISC Manual 13th Edition, Page 13-10)12.00 in
5.07 in > 3.05 in[the original Uniform Force Method not apply]
-2.55 in0.396054.50812
4.16 in
14.38 in
24.86 in
143.0 kips
63.1 kips
12.5 ft-kips
81.0 kips
41.3 kips
-6.2 ft-kips
CHECK WELD CAPACITY AT INTERFACES (AISC 360-05 J2.4 )
10.37 ksi
4.58 ksi
2.73 ksi
13.90 ksi
7.09 ksi
7.51 ksi2.0
12.68 ksi < 21.00 ksi [Satisfactory]20.16 ksi < 21.00 ksi [Satisfactory]
loads combination of DL + LL + 2 dx/1.5 (AISC 341-05, 16.2b, 16.5b & ASCE 7-05, 12.8.6).
For the connection of gusset plate to beam and column, the interface dimensions of a and b may not satisfy the basic
relationship of the Uniform Force Method: a - b tanq = eb tanq - ec. This software can determine gusset dimensions
Pysc =
q =
2 b =2 a =
, ec =
, eb =
T = (1.1 / 1.5) b w Ry Pysc = b =w =
Ry =
> wMIN =
< wMAX =
tg = ( USE tg =
b =
a = (eb + b) tanq - ec =
K = eb tanq - ec =D = tan2q + (a / b)2 =K' = a ( tanq + a / b) =
aIdeal = (K' tanq + K (a / b)2 ) / D =
bIdeal = (aIdeal - K) / tanq =
r = [(eb + bIdeal)2 + (ec + aIdeal)2] 0.5 =
Vc = (bIdeal / r) T =
Hc = (ec / r) T =
Mc = Hc [ bIdeal - b ] =
Vb = (eb / r) T =
Hb = (aIdeal / r) T =
Mb = Vb [ aIdeal - a ] =
fVc = Vc / (4 b 0.707 w) =
fHc = Hc / (4 b 0.707 w) =
fMc = 3 Mc / (4 b2 0.707 w) =
fVb = VB / (4 a 0.707 w) =
fHb = HB / (4 a 0.707 w) =
fMb = 3 Mb / (4 a2 0.707 w) =W =
fv,c = [(fvc)2 + (fHc+ fMc)2] 0.5 = 0.6 FEXX / W =
fv,b = [(fvb)2 + (fHb + fMb)2] 0.5 = 0.6 FEXX / W =
b
a
b
a

PROJECT : PAGE :
CLIENT : DESIGN BY : JOB NO. : DATE : REVIEW BY :
Seismic Design for Buckling-Restrained Braced Frames Based on AISC 360-05 & AISC 341-05
INPUT DATA & DESIGN SUMMARYBEAM SECTION = > W16X67 = > A dBEAM DISTRIBUTED SERVICE LOADS D = 0.24 kips / ft 20 16.3 0.40 10.20 0.67 119
L = 0.5 kips / ft kBEAM LENGTH 26 ft 970 6.96 2.44 132 1.37
1 Yes
150 kips,ASD (AISC 341, 16.5b)
25 kips
BEAM YIELD STRESS 50 ksi
THE BEAM DESIGN IS ADEQUATE.
CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1) < = does not apply for top flange continuously braced.
7.67 < N/A [Satisfactory]Where 29000 ksi
34.33 <N/A
N/A
[Satisfactory] Where 2.0 , (AISC 341-05, Table R3-1)
1000 kips
DETERMINE MOMENT ON THE BEAM
225.03 ft-kips, ASD
DETERMINE UNBALANCED SEGMENT LENGTH ABOUT X - AND Y - AXES
26 ft
13 ft
CHECK COMPRESSION CAPACITY (AISC 360-05 E3)
370.76 kips > [Satisfactory]Where 2.0 , (AISC 341-05, Table R3-1)
K = 1.0
63.95 < 200 [Satisfactory]
2.656
69.9786 ksi (AISC 360-05 E3)
37.08 ksi (AISC 360-05 E3)
DETERMINE FLEXURAL DESIGN STRENGTH (AISC-AISC 360-05 F1)
13.00 ft
8.62 ft
26.24 ft
550.0 ft-kips
138.688 ksi
Where 2.80 G J1.00 119 11200 2.62 7300
15.64 in
tw bf tf Sx
Ix rx ry Zx
L =
TOP FLANGE CONTINUOUSLY BRACED ?BEAM AXIAL LOAD AT 2dx/1.5 STORY DRIFT P2dx =
BEAM VERT LOAD AT 2dx/1.5 STORY DRIFT V2dx =
Fy =
bf / (2tf ) = 0.3 (Es / Fy)0.5 =
Es =
h / tw =3.14(Es/Fy)0.5(1-1.54P2DWo/Py) = , for P2DWo/Py < 0.125
1.12(Es/Fy)0.5(2.33-P2DWo/Py) = , for P2DWo/Py > 0.125
Wo =
Py = FyA =
M = (D + L) L2/ 8 + V2dx L/ 4 =
Lx =
Ly =
Pn/Wo = FcrA/Wo = P2dx
Wo =
MAX(KLx/rx, KLy/ry) =
lc = (KL / r) (Fy / E)0.5 =
Fe = p2 E / (KL / r)2 =
Fcr =
Lb =
Lp = 1.76 ry (E / Fyf)0.5 =
Mp = Fy Zx =
rts =[( Iy Cw)0.5/ Sx]0.5 = Iy Cw
c =
h0 = d - tf =
20
0
0.71.95 1 1 6.76
0.7x
y x
FE Jc y S hL rr ts E JcF S h
22
20
1 0.078b b
xb
E JcC LFcrS h rtsL
rts
p

1.30 , (AISC 360-05 F1)Cb =

(cont'd)
= N/A
= = 550
= N/A
275 ft-kips
CHECK FLEXURAL CAPACITY (AISC 360-05 C2.1b)
245.71 ft-kips < 275 ft-kips
Where 2852 kips [Satisfactory]1.0 (AISC 360-05 C2.1b)1.6
1.092
CHECK INTERACTION CAPACITY (AISC 360-05 H1.1)
1.20 < 4/3 [Satisfactory]N/A
Mp ft-kips, for Lb @ [0 , Lp]
Mn MIN{Cb [Mp - (Mp - 0.75 Fy Sx) (Lb - Lp) / (Lr - Lp)] , Mp} ft-kips, for Lb @ (Lp , Lr]
MIN(Fcr Sx , Mp) ft-kips, for Lb @ (Lr , Larger)
Mn/Wo =
M = B1M = Mn/Wo =
Pe1 = p2EsIx / (KLx)2 =
Cm =a =
B1 = MAX[ Cm/(1 - a P2D/Pe1) , 1.0] =
For P2D Wo/Pn≥0.2, P2D Wo /Pn + 8 / 9 (M Wo / Mn) =
For P2D Wo/Pn<0.2, P2D Wo / (2Pn) + M Wo / Mn =

PROJECT : PAGE :
CLIENT : DESIGN BY : JOB NO. : DATE : REVIEW BY :
Seismic Design for Buckling-Restrained Braced Frames Based on AISC 360-05 & AISC 341-05
INPUT DATA & DESIGN SUMMARYCOLUMN SECTION = > W12X96 = > A dCOLUMN AXIAL SERVICE LOADS D = 22 kips 28.2 12.7 0.55 12.20 0.90 131
L = 29 kips k100 kips, ASD (AISC 341, 16.5b) 833 5.43 3.09 147 1.50
UNBRACED COLUMN LENGTH 14 ft
COLUMN YIELD STRESS (36 or 50) 50 ksi THE COLUMN DESIGN IS ADEQUATE.
DETERMINE DESIGN LOAD (AISC 341-05, 16.2b & 16.5b)
151 kips, ASD (Compression, Governs)
CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)
6.78 < 7.22 [Satisfactory]Where 29000 ksi
17.64 <N/A
57.07
[Satisfactory] Where 2.0 , (AISC 341-05, Table R3-1)
1410 kips
CHECK COMPRESSION CAPACITY (AISC 360-05 E3)
568.31 kips > [Satisfactory]Where 2.0 , (AISC 341-05, Table R3-1)
K = 1.0
54.29 < 200 [Satisfactory]
2.254 (AISC 360-05 E2-4, Pg 6-47)
97.0943 ksi (AISC 360-05 E3)
40.31 ksi (AISC 360-05 E3)
tw bf tf Sx
Ix rx ry Zx
COL AXIAL LOAD AT 2dx/1.5 STORY DRIFT P2dx =L =
Fy =
P = D + L + P2dx =
bf / (2tf ) = 0.3 (Es / Fy)0.5 =
Es =
h / tw =3.14(Es/Fy)0.5(1-1.54PWo/Py) = , for PWo/Py < 0.125
1.12(Es/Fy)0.5(2.33-PWo/Py) = , for PWo/Py > 0.125
Wo =
Py = FyA =
Pn/Wo = FcrA/Wo = P
Wo =
MAX(KLx/rx, KLy/ry) =
lc = (KL / r) (Fy / E)0.5 =
Fe = p2 E / (KL / r)2 =
Fcr =