BOQ Financial

26
Planning Solution Tourism Corporation of Guajrat Ltd(TCGL) Sr. No. Description Qty Unit Rate Amount 1 Excavation for foundation upto 1.5 M. depth including sorting out and stacking of useful materials & disposing of the excavated stuff upto 150M. Lead including shoring, strutting, de-watering if required etc. complete. (a) Loose or soft soil. 7862.28 Cu.mt. 2 Excavation for pipe line trenches incl. all safety provisions using site rails and stacking excavated stuff up to any lits &left. cleaning the site etc. complete for lifts and strata as specified. (a) 1.50 mt to 3.00 mt depth 42.29 Cu.mt. b 3.00 mt to 4.50 mt depth 42.29 Cu.mt. c 4.50 mt to 6.00 mt depth 42.29 Cu.mt. d 6.00 mt to 7.50 mt depth 42.29 Cu.mt. e 7.50 mt to 9.00 mt depth 42.29 Cu.mt. f 9.00 mt to 10.50 mt depth 28.19 Cu.mt. 3 Filling available excavated earth (excluding rock) in trenches , plinth,sides of foundation etc. in layers not exceeding 20 cm. in depth conceeliding each deposited layer by ramming & watering. 2255.65 Cu.mt. 4 Filling in foundation and plinth with murrum of selected soil in layers of 20 cm.thickness including watering ramming , consolidation and etc. complete, 6322.51 Cu.mt. 5 Providing pre-construction termite proofing treatment as per IS : 6313 (PART II) under foundations, floors, including required for a guranteed period of 10 years as specified and directed ( Measurement as per "Built up " area of specified buildings). 4887.70 Sq.M. 6 Providing and laying cement concrete 1:4:8 (1cement : 4 coarse sand : 8 hand broken stone aggegates 40 m.m. nominal size) and curing complete.excluding cost of form work in: (a) Foundation and plinth 2191.51 Cu.mt. 7 Providing and laying controlled cement concrete M- 250 and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in : (a) Foundations, footings Bass of columns and mass concrete. 305.95 Cu.mt. b Slabs, Landings, shelves, Balconies, Lintels, Beams, Girders and cantilever upto floor two level. 628.15 Cu.mt. c Columns, pillars posts and struts upato floor two level 356.01 Cu.mt. 8 Providing form work of ordinary tiber planking centering , shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not ex-ceeding 4M.and removal of the same for in situ reinforced concrete work in: (a) Foundation, footings,Bases of columns etc. and Mass concrete. 767.22 Sq.M. b Flat surfaces such as soffits of slabs landings and the like 1 Floors etc. upto 200mm in thickness 890.69 Sq.M. c Columns, pillars , posts and struts 1621.36 Sq.M. d 1 Sides and soffits of Beams ,Beam, haunchings, canati-lever Griders , Bressumers and Lintels not excedding 1 M.in depth . 3051.51 Sq.M. DEVELOPMENT OF ARRIVAL PLAZA, PRADAKSHINA PATH, AND FORT WALL RESTORATION ETC. AT BAHUCHARAJI MATA TEMPLE PREMISE, BAHUCHARAJI . DIST: MEHESANA BOQ/1

description

bid

Transcript of BOQ Financial

Page 1: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

Sr. No. Description Qty Unit Rate Amount

1

Excavation for foundation upto 1.5 M. depth including

sorting out and stacking of useful materials & disposing

of the excavated stuff upto 150M. Lead including

shoring, strutting, de-watering if required etc. complete.

(a) Loose or soft soil.

7862.28 Cu.mt.

2

Excavation for pipe line trenches incl. all safety

provisions using site rails and stacking excavated stuff

up to any lits &left. cleaning the site etc. complete for

lifts and strata as specified. (a) 1.50 mt to 3.00 mt

depth

42.29 Cu.mt.

b 3.00 mt to 4.50 mt depth 42.29 Cu.mt.

c 4.50 mt to 6.00 mt depth 42.29 Cu.mt.

d 6.00 mt to 7.50 mt depth 42.29 Cu.mt.

e 7.50 mt to 9.00 mt depth 42.29 Cu.mt.

f 9.00 mt to 10.50 mt depth 28.19 Cu.mt.

3

Filling available excavated earth (excluding rock) in

trenches , plinth,sides of foundation etc. in layers not

exceeding 20 cm. in depth conceeliding each deposited

layer by ramming & watering.

2255.65 Cu.mt.

4

Filling in foundation and plinth with murrum of

selected soil in layers of 20 cm.thickness including

watering ramming , consolidation and etc. complete,

6322.51 Cu.mt.

5

Providing pre-construction termite proofing treatment

as per IS : 6313 (PART II) under foundations, floors,

including required for a guranteed period of 10 years as

specified and directed ( Measurement as per "Built up

" area of specified buildings).

4887.70 Sq.M.

6

Providing and laying cement concrete 1:4:8 (1cement

: 4 coarse sand : 8 hand broken stone aggegates 40

m.m. nominal size) and curing complete.excluding cost

of form work in: (a) Foundation and plinth

2191.51 Cu.mt.

7

Providing and laying controlled cement concrete M -

250 and curing complete excluding the cost of form

work and reinforcement for reinforced concrete work in

: (a) Foundations, footings Bass of columns and mass

concrete.

305.95 Cu.mt.

bSlabs, Landings, shelves, Balconies, Lintels, Beams,

Girders and cantilever upto floor two level.628.15 Cu.mt.

cColumns, pillars posts and struts upato floor two level

356.01 Cu.mt.

8

Providing form work of ordinary tiber planking

centering , shuttering strutting and propping etc. Height

of propping and centering below supporting floor to

ceiling not ex-ceeding 4M.and removal of the same for

in situ reinforced concrete work in: (a) Foundation,

footings,Bases of columns etc. and Mass concrete.

767.22 Sq.M.

bFlat surfaces such as soffits of slabs landings and the

like 1 Floors etc. upto 200mm in thickness 890.69 Sq.M.

c Columns, pillars , posts and struts 1621.36 Sq.M.

d

1 Sides and soffits of Beams ,Beam, haunchings,

canati-lever Griders , Bressumers and Lintels not

excedding 1 M.in depth .

3051.51 Sq.M.

DEVELOPMENT OF ARRIVAL PLAZA, PRADAKSHINA PATH, AND FORT WALL RESTORATION ETC. AT BAHUCHARAJI MATA

TEMPLE PREMISE, BAHUCHARAJI . DIST: MEHESANA

BOQ/1

Page 2: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

9

Providing T.M.T. (Thermo Mechanically Treated) ribbed

bar reinforcement (I.S.I Mark) for RCC work including

bending binding and placing in position complete upto

floor two level.

110664.46 KG

10

Brick work using common burnt Fly Ash building bricks

having crushing strength not less than 35 Kg/sq.cm. in

foundation and plinth in cement mortar 1:6 (1 cement;

6 fine sand ).

755.71 Cu.mt.

11Extra for brick work in super structure above plinth level

upto floor two level. (a) C:M 1:6495.60 Cu.mt.

12Extra for half brick masonary in super structure above

plinth level upto floor two level.766.38 Sq.M.

13

Providing 15 mm. thick cement plaster in single coat

on fair side Brick / concrete walls for interior plastering

upto floor two level and finished even and smooth in :

(a) Cement mortar 1:4(1 cement,4 sand ) (ai) For Wall

6559.50 Sq.M.

aii For Ceilling 1494.12 Sq.M.

14

Providing & applying Stone Crete Plaster using grey

cement & sand in proportion 1:3, over a coat of rough

cast plaster, inclusive of surface preparation, applying

the plaster in two coats, finishing as required,

scaffolding, cleaning, curing etc. complete at all levels,

heights & shapes (without Grooves).

2778.86 Sq.M.

15

Providing and laying water proofing treatment on

terrace including applying neat cement slurry 2.75

Kg/Sqmt. on cement admixed with water proofing

component after cleaning the surface, laying cement

concrete with brick bat 75mm to 100mm thick with 50%

of C:M 1:5 admixed with water proofing component over

20mm thick layer of C:M 1:5 to required slope including

ramming at junction of wall and slab, after two days of

proper curing applying a second coat of cement slurry

finished the surface with 20mm thick C:M 1:4 china

mosaic flooring and finally finished surface with white

cement slurry, after finishing with terrace shall be

finished with water for a period of two weeks.

796.80 Sq.M.

16

Providing & applying polymer based approved

Chemical waterproofing system for Gutter as per

manufacturer's specifications & detailed instructions.

The surface shall be thoroughly cleaned & all the dirt &

loose particles shall be removed before applying the

chemical system.

231.54 Sq.M.

17

Providing & filling brick-bat cement concrete in the

toilet & kitchen sunks after waterproofing & laying pipes

etc. complete without damaging the same.57.00 Cu.mt.

18

Providing and laying granite flooring tiles 8mm thick

in flooring treads of steps and landings laid on a bed of

12mm thick cement mortar 1:3 (1 cement; 3 coarse

sand ) finished with flush pointing in white cement.

4386.27 Sq.M.

19 Same as above but for Kota Stone Flooring 3437.33 Sq.M.

20 Same as above but for White Marble Tread Top 650.61 Sq.M.

21 Same as above but for White Marble Flooring. 1814.42 Sq.M.

22Same as above but for Pink Jaipur Stone Flooring

3555.70 Sq.M.

23 Same as above but for Yellow Jaisalmer Riser 407.46 Sq.M.

BOQ/2

Page 3: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

24

Providing and fixing 150mm wide white marble coping

over the brickwork using cement sand mortar 1:4,

closely jointed and pointed with white cment and

matching colour pigment, edge moulding to required

shape on both sides, all in perfect line, level and

plumbing etc. complete.

379.41 Rmt

25

Providing and fixing granite seating out of 20mm thk

granite stone, fixed to the wall and supported by

triangular cut stone pieces below, including chasing the

wall, embedding in the marble and stone all as per

drawings and perfect line and level etc. complete. Only

the front edge length shall be measured for payment.

1425.15 Rmt

26

Providing & fixing Coarsed Stone Cladding, using

approved quality & size stone, fixed to the rough

plastered wall surfaces with cream of cement spread

uniformly over the back of the stone, tapping the stone

gently to stick to the wall surfaces, closing the joints &

pointing as required & as per approved sample of the

cladding, cleaning, curing, rubbing etc. complete all in

perfect line, level & plumb. Basic Rate Rs. 40/- per sft.

348.40 Sq.M.

27

Providing & fixing Granite Stone Cladding, using

approved quality & size stone, fixed to the rough

plastered wall surfaces with cream of cement spread

uniformly over the back of the stone, tapping the stone

gently to stick to the wall surfaces, closing the joints &

pointing as required & as per approved sample of the

cladding, cleaning, curing, rubbing etc. complete all in

perfect line, level & plumb. Basic Rate Rs. 225/- per sft.

358.87 Sq.M.

28

Providing & laying first quality Ceramic tiles of 20" X

20" or 24" x 24" size & of approved make, (Basic rate

Rs. 400/- per M2), for floor, laid over 20-25 mm

average thick cement sand mortar bed of 1:4 mix. A

3mm groove to be made using pvc spacers and joint to

be filled with LATAPOXY SP 100 stainless epoxy grout

of approved shade and as per manufactures

specification. Contractor to consider masking of all

sides of tile using paper tape before applying the grout

to avoid staining on tile surface, complete to proper

slopes and grade, curing, rubbing, cleaning as per

detailed specification etc. at all levels.

418.47 Sq.M.

29

Same as above but for Glazed tiles dado (Basic rate

Rs.400/- per M2) fixed using BAL adhesive or

equivalent/ approved product to the toilet & kitchen

walls, inclusive of using plastic spacers to perfect line,

level & plumb etc. complete.

458.61 Sq.M.

30

Providing and fixing RCC Curbing made out of M25

grade concrete in size 150mm x 375mm cross section

and fixed in PCC 1:2:4 to secure it in position inclusive

of required excavation, back filing, casting and placing

the kerb stone etc. complete; all in perfect line, level

and plumb.

695.71 Rmt

31

Providing and fixing 150mm wide Granite coping over

the brickwork using cement sand mortar 1:4, closely

jointed and pointed with white cement and matching

colour pigment, edge moulding to required shape on

both sides, all in perfet line, level and plumb etc.

complete.

894.45 Rmt

BOQ/3

Page 4: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

32

Providing & fixing 75mm high skirting projecting not

more than 8mm from the wall plaster line and same as

flooring material used, fixed in CM 1:3, curing, hand

polishing, inclusive of providing C groove with

aluminium as per detailed specification etc. complete.

(a) Granite Skirting

665.42 Rmt.

33

Providing and fixing Sand Stone Frame for doors as

per design inclusive of holdfasts, fixing the same to the

masonry work with all the cement sand mortar etc.

complete..

124.70 Rmt

34

Providing and laying interlocking road paver block of

minimum 40mm thickness and compressive strength of

300kg/Sq.cm. with necessary fixing on minimum 40 to

50 mm thick sharp sand or stonedust bedding including

Kerbing stone on bothside of block paving of size 400

mm x 200 mm x 100 mm finishing the joints with

sweeping dry fine sand or stone dust in to joints

including vibrating with plate compector etc.

completed.The vertical joints of the Curbing shall be

finished with 1:2:4 concrete

163.00 Sq.M.

a block near entrance 32.08 Rmt

b block near temple 45.20 Rmt

35

Providing & fixing granite urinal partition of size 4' X

2' 6" inclusive of making jarries in the wall, fixing it with

cream of cement, supporting till set in position, edge

polishing etc. complete.

29.00 Nos.

36

Providing and fixing rolling shutters of approved make

made of 30 mm. wide M.S. Laths interlocked together

through their entire length and jointed together at the

end locks mounted on specially designed pipe shaft wih

bracket plates, guide channels and out side locking with

pushpull operation including the cost of Hood cover and

spring etc. complete. (a) Shutters having width below

3.5m.

294.46 Sq.M.

37

Providing & fixing 35mm thick solid core flush door

shutters, in single leaf as per detailed drawing. The

flush doors shall be factory made solid core block board

shutters bonded with phenol formaldehyde resin. The

lipping shall be of teakwood all round the flush door with

a minimum thickness of 12mm. The shutter shall be

painted with two coats of Polyurethane Enamal paint

on both sides of approved make & shade to the

satisfaction of the architect. The following aluminium

fittings shall be used: (a) - 2-Handles.

89.04 Sq.M.

38

Providing and fixing fully glazed alluminium window

partly fixed and partly sliding shutter with frame section

63.5 x 38.1 x 1.02mm weighing 0.547 Kg/Rmt. Shutter

section 40mm x 18mm x 1.55mm weighing 0.547

Kg/Rmt. Bottom , top and vertical channel section

61.85 x 31.75 x 1.20mm weighing 0.695 Kg/Rmt.

extruded allumium colour anodized section frame with

sliding shutter with 5mm thick transparent bronze

colour tinted float glass panel of modi guard or

equivalent make with power coated allumium fittings

and fixtures and transparent silicon sealent glass fixing

to from as detail including PVC T in frame silicon based

lining handles locks two nos. PVC gasket screws

alluminiumjoints special runners etc. complete.

28.92 Sq.M.

BOQ/4

Page 5: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

39

Providing and fixing glass reinforced concrete jali

(GRC) 50mm thk. As per the design of architects.

Including fixing to wall in cement:sand mortar all in

perfect line and length complete

55.57 Sq.M.

40

Providing and fixing aluminum glazed louvers

inclusive of white anodize aluminum heavy duty

sections and 100mm wide wired opaque glass louvers

etc. complete.

22.98 Sq.M.

41

Providing & fixing MS galvalume coated corrugated

sheets roofing system (Proflex) curved to shape,

using required thickness of corrugated MS sheets as

per design of the vendor (Proflex or approved

equivalent); fixed directly to the RCC gutter at ends

using necessary holdfasts etc. and without any

structural members supporting the sheets in between

the span, all in perfect line, level & plumb. The rate shall

include all the laps & wastages etc. complete. Only net

laid area shall be measured for payment. Ridges,

flashings etc. shall not be paid for separately. All the

curving shall be done carefully at the site and the

sheets lifted and placed by crane.

2940.13 Sq.M.

42

Providing & fixing 10 mm thick multi-wall

polycarbonate sheet skylight over the cut outs as

shown on drawings, fixing the polycarbonate sheets to

the MS closed structure by means of aluminium

extruded sections, EPDM gasket screwed to the steel

structure & sealing the joints completely with approved

sealent to make them waterproof, inclusive of closing

the vertical gaps with the same sheet, cleaning,

finishing neat, scaffolding upto any height etc. complete

all as per directions of the EIC. The rate to include for

all the laps & wastages, flashings etc. Only net laid area

of the sheet shall be measured for payment.

279.25 Sq.M.

43

Wall painting ( three coats) with plastic emulsion

paint of approved brand & manufacture on wall

surfaces to give an even finis brushing the surface free

from mortar droppings & other foreign matter & sand

papered smooth etc. complete.

2515.39 Sq.M.

44

Supplying, transporting, fabricating & erecting,

structural steel beams & columns from rolled or/and

built up sections and plates welded to each other as

specified & directed at all levels including cutting,

welding, seal welding, bolting, threading, wherever

necessary and generally as per the enclosed

specifications and drawings. etc. complete as specified

and directed. Also inclusive of providing & applying 2

coats of Zinc chromate primer after sand blasting the

steel to commercial quality. The primer to have a

125micron DFT (Dry Film Thickness)

1417.62 Kgs

45 30mm dia. M.S. Pipe 2211.92 Kgs

46 10mm M.S. Thick Flat 288.22 Kgs

47 M.S Railing 27.04 Kgs

48

Providing, fabricating and fixing in position M.S. Grill in

window openings from M.S. flat etc. as per detailed

drawings and specifications of Architect including

applying approved make red oxide zinc chrome primer

and two coats of 1st quality synthetic enamel paint of

approved make and shade etc complete with all labour,

tools and material.

100.30 Kgs

BOQ/5

Page 6: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

49

Providing and fixing SSFolded Seating with 1mm thk

perforated top and SS pipes as per manufacturer's

design to withstand public wear and tear, all as per

design and to the approval of the architect etc.

complete.

90.00 Nos.

50

Providing and fixing SS Grill to the RCC columns with

minimum opening to prevent human entry, all in hollow

SS pipe sections and heavy gauge, including fixing the

same to the floor, RCC columns using necessary

holdfasts, fasteners etc. complete. (Wt. 1.5 kg/Sft).

529.20 Sq.M

51

Providing and fixing SS Railing of 1.0M height to the

RCC columns with minimum opening to prevent human

entry, all in hollow SS pipe sections and heavy gauge,

including fixing the same to the floor, RCC columns

using necessary holdfasts, fasteners etc. complete.

(Wt. 10 kg/Rft).

438.00 Rmt.

52

Providing and sowing Creepers inclusive of required

excavation, dressing, filling sweet earth as required,

watering and keeping alive all the creepers for one year

all as per direction of the architect etc. complete.

695.71 Sq.M

53 Providing and fixing CI cover with frame 60.00 Nos

54Providing and fixing C.I. M.H. frame and cover (60 cm

X 60 cm)120.00 Kg.

55

Providing high quality plastic litter bins hexagonal

equivalent to series "GBVFSS", GBVFSS 08-03, colour:

blue for bin & black for M.S strusture.18.00 Nos.

56Providing and Laying M.S.Jali,Including placing in

position complete as per details. 163.00 Sq.M

57

Providing and fixing (Two level or slopes) and jointing

with stiff mixture of cement mortar in proportion 1:1 salt

glazed stone ware pipes following nominal internal

diameter including testing of pipes and joints etc.

complete.

78.00 Rmt.

58

A-Type Tree Providing and sowing inclusive of required

excavation, dressing, filling sweet earth as required,

watering and keeping alive all the creepers for one year

all as per direction of the architect etc. complete.72.00 Nos.

59

B-Type Tree Providing and sowing inclusive of required

excavation, dressing, filling sweet earth as required,

watering and keeping alive all the creepers for one year

all as per direction of the architect etc. complete.67.00 Nos.

60

Providing and constructing the following stonework as

per detailed drawings and specifications; including

required finishes and all in perfect line, level and plumb

and to the satisfaction of the architect etc. complete. (a)

Bansipahrpur Stone Work (See attached details) 348.83 Cmt

bDhangadhra Stone Work (See attached details)

244.31 Cmt

c Marble Slabs 1568.57 Smt

d Brick Masonry 172.61 Cmt

BOQ/6

Page 7: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

61

Dismantelling Buildings (below & above

plinth)including flooring,R.C.C,steel

cutting,Masonary,plaster,Removing door &

Window,Removing pipe,plumbing instuments, drainage

line,etc Any building measurment of plinth area.All

usable material is Client property.Removing all the

anusible debris or any material stuff up to any lits &left.

1423.54 Sq.M

62

Providing & laying in Wall, celling and floors galvanized

mild steel tubes (medium grade) of the following

nominal bore, & tube fittings and clamps including

making good the wall , ceiling and floor. (a) 15mm dia. 220.00 Meter

b 20mm dia. 125.00 Meter

c 25mm dia. 185.00 Meter

d 32mm dia. 125.00 Meter

e 40mm dia. 190.00 Meter

f 50mm dia. 250.00 Meter

63

Providing & laying in trenches galvanized mild steel

tubes (medium grade) of the following nominal bore, &

tube fittings( Earthwork in trenches to be measured and

paid for separately). (a) 65mm dia. 50.00 Meter

64

Making connection of galvanized mild steel

distribution branch with galvanized Mild steel main 50

mm. to 80mm. Nominal bore by providing and fixing too

including cutting and threading the pipes complete. 7.00 Each.

65

Providing and fixing cast iron spigot and socket soil ,

waste and ventilating pipes of the following nominal

size. (a) 75mm dia. 310.00 Meter

b 100mm dia. 260.00 Meter

66Providing and fixing in position cowl vent to pipes: (a)

75mm dia. 10.00 Each

b 100mm dia. 10.00 Each

67

Providing and fixing cost iron (spun) Nahni trap of the

following nominal diameter of self cleaning design with

C.I. Screwed down or hinged gratting including cost of

cutting and making good the walls and floors 100mm.

Inlet and 50mm. Outlet.

38.00 Each.

BOQ/7

Page 8: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

68

Paroviding and fixing water closet squatting pan (

indian type w.c. pan ) size 580mm. Inclusive of Earth

work, Bed concrete, vitreous china 250mm x 120mm x

30mm foot rests, 100mm size 'P' or 'S' trap and 12.5

liters high level flushing cistern with pair of MS brackets

and lead value siphon, polythene float, CP brass handle

union and couplings for connections, making hole in the

wall and making good the same, fixing clamps and

32mm dia. GI pipes and connection for flush pipe etc.

complete.

(A) Vitereous china Long patten white colour

16.00 Each.

69

Providing and fixing wash basin with single hole for

pillar tap with C.I. Or M.S. brackets painted white

including cutting holes and making good the same

including 40mm dia. CP brass waste and 40mm dia. MI

fisher union and CP Bottle trap etc. complete. (a) In

white colour

16.00 Each

70

Providing and fixing Kitchen sink with C.I. Or M.S.

brackers painted white including cutting holes and

making good the same including 40mm dia. CP brass

waste and 40mm dia. MI fisher union etc. complete.

Vitereous china sink (a) 600 mm x 450 mm x450mm

size.

8.00 Each

71

Providing and fixing 100 mm. sand coast iron grating

for gully floor or nahnin trap. 38.00 Each

72

Providing & fixing C.P. brass shower rose with 15mm

or 20mm inlet. (a) 100mm. Dia. 6.00 Each

73

Providing & fixing 600mm x 450mm Bevelled edge

mirror of superior glass mounted on 6mm thick A.C.

sheet or plywood sheet & fixed to wooden plugs with

C.P. brass screws & washers.16.00 Each

74

Providing and fixing C.P brass towel rail complete with

C.P. brass bracket and guard rail complete. Fixed to

wooden plug with C.P. brass screws. (a) 600mm x 20

mm. size.16.00 Each

75

Providing & fixing screw down bib taps of following

size. (a) Brass chromium plated screw down bib tap.

15mm dia28.00 Each

76

Providing & fixing pillar tap, capstan head, screw down

high pressure with screws, shanks & backnuts. (a)

15mm dia.8.00 Each

77Providing and fixing brass screw down stop cock (a)

15mm dia. 16.00 Each

78

Providing and fixing gun metal check or nonreturn

fullway wheel valve. (a) 40mm dia. 7.00 Each

BOQ/8

Page 9: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

79

Providing and fixing chromium plated brass half turn

flush cock of approved quality including fixing in pipe

line etc. complete. (a) 20mm.dia. 10.00 Each

80

Providing and fixing urinal of appoved connecting the

urinal with waste pipe , trap etc. complete. (a) White

earthern ware flat back or corner type size 430 mm x

260 mm x 350mm. 30.00 Each

b Squatting Urinal 6.00 Each

81

Providing and fixing ball cock of approved quality as

directed. (a) Copper metal for 50mm dia 7.00 Each

82

Providing and fixing C.I. Manhole cover 0.60m.x 0.45

m size having weight not less than 35 kgs. 32.00 Each

83

Providing and fixing (Two level or slopes) and jointing

with stiff mixture of cement mortar in proportion 1:1 salt

glazed stone ware pipes following nominal internal

diameter including testing of pipes and joints etc.

complete. (a) 100 mm. dia.80.00 Meter

b 150 mm. dia 100.00 Meter

84

Providing and fixing cement concrete 1:5:10 (1

cement :5 fine sand : 10 graded stone aggregate 40

mm. nominal size ) bending for stone - ware pipes of

following internal diameters with necessary form work

and curing complete. (a) 100 mm. dia. - ( 112 mm.

average bed thickness )

80.00 Meter

b150 mm. dia - ( 116 mm. average bed thickness )

100.00 Meter

85

Extra over item 24-1 for providing salt glazed stone

ware fittings- (a) Bends of required Degree (any

radius ) of following internal diameters- 100mm dia 8.00 Each

aii 150 mm.dia 5.00 Each

86

Providing and fixing S.W. Gully trap with C.I. Grating

brick masonary chamber and water tight C.I. Cover with

frame of 300 mm x 300 size ( inside ) with standard

weight. (a) Square mouth traps. 150 mm x 100 mm

size p - or R type.24.00 Each

87

Providing and laying ( two level or slopes ) and jointing

reinforced concrete light duty , non pressure pipes I.S.

Class N/P2 of the following internal diameter with collars

and butt ends prepared for collar joints including testing of

joints. (a) 300 mm

100.00 Meter

b 450 mm 25.00 Meter

c 600 mm 25.00 Meter

BOQ/9

Page 10: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

88

Constructing manhole with R.C.C. top 1:2:4 mix ( 1

cement : 2 coarse sand : 4 graded stone aggregate 20

mm. nominal size , foundation concrete 1:3:6 mix ( 1

cement : 3 coarse sand : 6 Brick bats 40 + 50 mm. size

) inside plastering 15 mm. thick with cement mortar 1:5

( 1 cement : 5 coarse sand ) finished with a floating

coat of neat cement and making channels in cement

concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone

aggregate 20 mm. nominal size ) finished smooth

complete including curing and tesing .(i) inside size 900

mm x 1200 mm.and 1:5 mm deep including C.I. cover

with frame size 560mm. total weight of cover and frame

to be not less than 128 Kgs. (Wt.of frame64 Kgs) (A)

With 230 cm. thick walls of brick masonry using brick

having crushing strength not less than 35 Kg/sq. cm. in

cement mortar 1:5(1cement :5coarse sand(1) A type

depth 0.90 metre for 150mm diameter sewer.

32.00 Each

89

Supplying and fixing C.I. Cover 300 mm. x 300 mm.

without frame for gully trap ( Standard pattern) the

weight of cover to be not less than 4.35 Kg. 24.00 Each

90

Providing and erecting at site of work steel ventilating

column of 150 mm. interna diameter and 12.20 Metre

high from G.L. to bottom of top grill,including C.I. Grill

and base plate, bolts and nuts etc. and excavation in

foundation of size 120 cm.x 120 cm.x 160 cm. and

filling the pit with first layer of cement concrete 1:3:6 ( 1

cement : 3 coarse sand : 6 graded stone aggregate 20

mm. size ) and providing fillet in cement concrete 1:2:4

( 1cement, 2 coarse sand , 4 graded stone aggregate

20 mm. Nominal size ) at G.L.and 3 coats of silver paint

etc. complete.

3.00 Each

91

Constructing brick masonary road gully chamber

500 mm. x 450 mm.x 600 mm. including 500 mm. x

450 mm. C.I. Horizontal grating with frame complete. 24.00 Each

92

Providing soak pit of 5.0 cu.mt. volume including

excavating sand filling brick bats with dry masonary

work at top for 5 CM hight including coveringthe top

with stone including providing vatas in C:M 1:3 with

finishing curing etc. complete.7.00 Each

BOQ/10

Page 11: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

93

Point wiring for secondary light point with 2-1.0

sq.mm & earthwire of 1.0 sq.mm (green) both are of

.ISI marked FR PVC insulated multistrand copper

wires, in existing pipe duly erected complete with earth

continuity and necessary connection with primary light

with accessories erected on polished wooden

block/Metal/ PVC box covered with 3 mm thick

laminated sheet for open / concealed wiring. Note:-

Maximum up to 6 mtrs length, excess will be

considered as Mains for Secondary Point. (a) For

Concealed Wiring

190.00 Pt.

94

Point wiring for Light / Bell / Primary Point with 2-1.5

sq.mm & earth wire of 1.0 sq.mm (green) both are of

ISI marked FR PVC insulated multistrand copper wires,

in existing pipe duly erected complete with 6 A Modular

type switch / bell push & accessories erected on PVC /

Metallic box covered with appropriate front plate

modules erected concealed in wall / ceiling . (a) Textd /

Metallic front plates Cat - II

450.00 Pt.

95

Point wiring for Fan Point with 2-1.5 sq.mm & earth

wire of 1.0 sq.mm (green) both are of ISI marked FR

PVC insulated multistrand copper wires, in existing pipe

duly erected complete with 6 A Modular type switch and

Hum free EME 5/6 step type electronic fan regulator

with earth continuity of following type erected on PVC /

Metallic box covered with appropriate front plate

modules erected concealed in wall / ceiling . (a) Textd /

Metallic front plates Cat - II

235.00 Pt.

96

Point wiring for individual plug with 2-1.5 sq.mm &

earthwire of 1.0 sq.mm (green) both are of ISI marked

FR PVC insulated multistrand copper wires, in existing

pipe duly erected complete 6 A Modular type switch

and 6 A 5 pin plug erected on PVC / Metallic box

covered with appropriate front modular plate modules

erected concealed in wall / ceiling with following type of

accessories (a) Textd / Metallic front plates Cat - II

60.00 Pt.

97

Point wiring for looped PLUG with 6 A Modular type

switch and 6 A 5 pin plug erected on PVC / Metallic

box covered with appropriate front modular plate

modules erected concealed in wall / ceiling with

following type of accessories (a) Textd / Metallic front

plates Cat - II

100.00 Pt.

BOQ/11

Page 12: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

98

Point wiring for Two way controlled light Point with

2-1.5 sq.mm & earth wire of 1.0 sq.mm (green) both

are of ISI marked FR PVC insulated multistrand copper

wires, in existing pipe duly erected complete with earth

continuty with 6 A Modular type switch / bell push &

accessories erected on PVC / Metallic box covered

with appropriate front plate modules erected concealed

in wall / ceiling . (a) Textd / Metallic front plates Cat - II

10.00 Pt.

99

Providing following type of Modular Type Accessories

mounted with pvc / metallic box covered with

appropriate front plate modules erected with necessary

connection. (a) One No. SP 6 Amp or One No 5 pin

plug Cat.II

10.00 Ea.

b

Three No 6A SP switch or Two Nos SP Switch and

One No 6A 5 Pin Plug or One No SP Switch and Two

Nos 6Amp. 5 Pin plug Cat.II

3.00 Ea.

c(4) Two Pin/ RJ-11 Telephone Socket with Top

Cat.II 10.00 Ea.

d TV Co-axial Socket outlet Cat.II 11.00 Ea.

e Blank Plate Single Cat.II 30.00 Ea.

f 16 Amp. SP one way switch Cat.II 65.00 Ea.

g (11) 6/16Amp. Universal socket Cat.II 65.00 Ea.

100

Providing and erecting 1.5 mm thick FIA approved and

ISI mark (embossed) RIGID PVC PIPES of following

size complete erected with necessary PVC fittings &

Junction boxes fixed with adhesive solution & Clamps

with following type of erection. For erecting concealed

in wall/slab along with continuous fish wire to draw

mains, laid in approved manner with plastering by

cement mortar & finishing the surface to match the

wall/ceiling. (a) 20 mm

2500.00 Mtr.

b 25 mm 500.00 Mtr.

c 32 mm 200.00 Mtr.

101

Providing & erecting PVC Corrugated Flexible

Conduit with required nos. of coupling, PVC bushes,

Check-nuts etc. complete of following sizes. (a) 16 mm50.00 Mtr.

b 20 mm 50.00 Mtr.

102

Supplying and laying UPVC cable trunking system

comprising unplasticised polyvinyl, chloride rigid

material with ignition free & flame proof confirming BS -

6099-2-2 & BS 4678-4 with necessary end caps

Internal & external bend, flat bends, coupler, tee etc..All

necessary accessories and measuring of following

sizes. (a) 50 mm x 25 mm trunking

300.00 Mtr.

103

Mains with 1.1 KV grade FR PVC insulated ISI marked

stranded Copper conductor wire in existing pipe

erected with 2.5 sq mm copper conductor FR PVC

insulated wire of green color for earth h continuity of

following size. (a)4 wire 6 sqmm

200.00 Mtr

BOQ/12

Page 13: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

104

Mains with ISI marked electrolyte stranded copper

conductor, Non PVC Zero Halogen free fire retardant

insulated copper conductor, insulated wire (HFFR)

conforms to IEC 332-1 & 3, IEE 383, IEC 745-1&2, IS-

694, erected in existing pipe with 1.5sq. mm copper

conductor of same specifications for earth continuity of

following size. (a) 2 wire 1.5 sq. mm

50.00 Mtr.

b 2 wire 2.5 sq. mm 900.00 Mtr.

c 2 wire 4 sq. mm 900.00 Mtr.

d 4 wire 4 sq. mm 200.00 Mtr.

105

Providing & Erecting following size of TV Co axial

flexible cable comprising inner conductor of solid bare

copper insulated with Foam PE & Secondary conductor

made of Poly Aluminium film bonded. Al Braids @

coverage of 65%, overall sheathed with black PVC

insulation.(COMMSCOPE / FINOLEX /

NORTHAMERICAN / CRABTREE / RRCABLE) (a)

RG - 6

1500.00 Mtr.

106

Supplying & erecting Delton or approved make

Telephone cable electrolytic grade annealed copper

conductor insulated with PE insulation twisted in to

pairs with colour combination bunched together in

concentric layers so as to minimizes cross-talk &

wrapped with FR PVC tape & sheathed with FR PVC or

HFFR outer Jacket suitable for indoor telephone wiring

& confirming to C-DOT S/WS - 113 / IEC 60189-2, UL-

1581 SECTION 1080 VW-1 erected in existing pipe of

following size of conductors & nos of pairs. With

necessary connections. Conductor Size 0.5 mm.

Unarmoured (a) '10) Two Pairs

500.00 Mtr.

b 12) Five Pairs 200.00 Mtr.

107

Supply & erecting M.S Box having 16 Guage painted

with red oxide Heavy duty PVC box erected flushed on

wall or concealed in wall with necessary plastering &

finishing of following size. 100 mm x 100 mm x 75

mm (d)

900.00 Ea.

108Providing & erecting 3 mm thick laminated sheet with

grooving as directed only Hylam Sheet.22500.00 Sq.Inch

109

Supplying & erecting Approved make call bell indicator

with buzzing sound and Red light indicating lamp with

Red light button to attend the call suitable for 240 v 50

cys supply to be erected on polished wooden board

with3mm thick laminated sheet with connections per

way.

2.00 Ea.

110

Supplying and erecting approved make. tube fitting with

One no T-5 tube 24 / 28 W with HFHC Electronic

ballast with THD less than 10 & built in adoptors,

GI/PVC housing & mirror optic reflector, suitable to

work on 120V - 300V, A.C. supply with connector

(Philips / Wipro) Cat.III

236.00 Ea.

111

Supply of approved make lumilux triphospher T-5

tube suitable to operate on 120V - 300 V of (Philips /

Wipro) (a) 28 W x 115 cms.

236.00 Ea.

b

Providing 45 to 50 cms. 16 SWG conduit pipe down

rod white painted with ball sockets and nipple for

suspension of fluorescent fitting complete erected with

concealed M.S. box covered with round 3 mm thick

laminated sheet with check nuts and 1.5 sq.mm copper

lead wire etc.

100.00 pair

cExtra for every additional 100 mm long double down

rod.200.00 pair

BOQ/13

Page 14: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

112

Providing and erecting approved make CFL decorative

Wall mounted luminaire complete with 9/11/13 watt

tube, ballast holder, clear / opal diffuser complete

erected with lead wire (Philips / Wipro) (a) for One

lamp Cat III

80.00 Ea.

113

Providing & erecting approved make decorative

recess/surface mounting type mirror optic luminare

complete with tubes, ballast, holder clear/opal diffuser

comlete erected with necessary lead wire.(Philips /

Wipro) (a) with two 9/11/13 W CFL Cat III

200.00 Ea.

114

Miniature circuit breaker single pole 6 A to 32A

suitable to operate on 240 V A.C. system and having

overload and short circuit tripping elements and

breaking capacity 10 KA to be erected in existing

M.S.box confirming to IS 8828/1996 with ISI mark

Cat III

400.00 Ea.

115

Providing & erecting 240 V MCB Double pole switch

for lighting load (B curve) having 10 KA breaking

capacity & confirms to IS : 8828 in existing box having

following capacity (a) 6-32 Amp Cat. III

129.00 Ea.

b 40 Amp Cat. III 5.00 Ea.

116

Providing & erecting 415 V MCB Four pole switch for

Lighting load (B curve) having 10 KA breaking

capacity & confirms to IS : 8828 in existing box having

following capacity (A) 40 Amp Cat. III

5.00 Ea.

117

Providing & erecting 415 V MCB Four pole switch for

motor & inductive load (C curve) having 10 KA

breaking capacity & confirms to IS : 8828 in existing

box having following capacity (A) 63 Amp Cat. III

15.00 Ea.

118MCB DISTRIBUTION BOARDS Half / One Module

Blanking Plate of Standerd Size20.00 Ea.

119

Providing and erecting Sheet steel powder coated MCB

Distribution board - flush / surface mounted fitted with

busbar, neutral link, earth bar and DIN rail, confirming

to IS 13032 and BS 5486-1986 without MCB to house

appropriate nos. of MCBs. (The DBs should be used of

same company of MCB to be used) - The qty. of

MCB's, I/c or O/g are to be as per SLD, The MCBs

are taken in above item. Quote only for DB box

With Acrylic cover (a) Single phase 4 way SS Double

door horizontal box

20.00 Ea.

b Single phase 6 way SS Double door horizontal box 65.00 Ea.

c Single phase 8 way SS Double door horizontal box 3.00 Ea.

d Single phase 12 way SS Double door horizontal box 11.00 Ea.

e(J) Three phase 4 way SS Double door single phase

outgoing horizontal box1.00 Ea.

fThree phase 6 way SS Double door single phase

outgoing horizontal box5.00 Ea.

gThree phase 8 way SS Double door single phase

outgoing horizontal box2.00 Ea.

120

Providing and erecting required size Hot deep

Galvanized strip for earthing of HT OCB / ACB /

Transformer / LT Panel board, Motors etc. using GI

clamp

300.00 Kg.

BOQ/14

Page 15: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

121

Supplying & erecting earth pit of minimum bore dia. 150

mm size, approved make Safe Earthing Electride

consisting Pipe-in-Pipe Technology as per IS 3043-

1987 made of corrosion free GI pipes having Outer pipe

dia of 50 mm having 80-200 Micron galvanising, Inner

pipe dia. of 25 mm having 200-250 Micron galvanising,

connection terminal dia of 12 mm with constant ohmic

value surrounded by highly conductive compound with

high charge dissipation suitable for following type of

applications. (a) For Electrical Installation covering

Transformer Neutrals, Lightining arrester Earthing, A.C.

Plant & Sensitive Computer System (like Automation,

SCADA) I.e.independent Earthing in normal soil Length

of Pipe:3.00 mtrs Back filling Compound : 2

nos Bags of 25 kg.

10.00 Ea.

122

Providing and erecting XLPE (IS:7098)(I)-88 ISI

marked unarmoured cable multistrand copper

conductor for 1.1 KV to be laid on wall with necessary

clamps or in existing cable trench / pipe at road

crossing or floor of following size of cables (a) 3 core

2.5 sq.mm

400.00 Mtr

123

Providing and erecting XLPE (IS:7098)(I)-88 ISI

marked armoured cable multistrand Aluminium

conductor for 1.1 KV to be laid on wall with necessary

clamps or in existing cable trench / pipe at road

crossing or floor of following size of cables (a) 3 1/2

core 25sq.mm (16 Sq.mm 1/2 core)

200.00 Mtr

b 3 1/2 core 70 sq.mm (35 Sq.mm 1/2 core) 250.00 Mtr

c 3 1/2 core 95 sq.mm (50 Sq.mm 1/2 core) 200.00 Mtr

124

Providing and erecting XLPE (IS :7098)(I) -88 ISI

marked armoured cable multistrand Copper

conductor for 1.1 KV to be laid on wall with nacessary

clamps or in existing cable trench / pipe at road

crossing or floor of following size. (a) 3 core x 4

sq.mm

50.00 Mtr

125

Providing and erecting XLPE (IS :7098)(I) -88 ISI

marked armoured cable multistrand Copper

conductor for 1.1 KV to be laid on wall with nacessary

clamps or in existing cable trench / pipe at road

crossing or floor of following size. (a) 4 core 4 Sq.mm

1500.00 Mtr

b 4 core 6 Sq.mm 900.00 Mtr

126

Making trench in soft soil of suitable width of 90 cms

deep for laying cable or locating the fault all over the run

and back filling the same and making the surface as

normal ground. (a) Upto 25 sq mm

1800.00 Mtr

b 35 sq mm to 95 sq mm 400.00 Mtr

127

Providing and laying R.C.C. hume pipe for cable to be

laid 90 cms below ground across the road crossing or

on floor with necessary material in an approved

manner. (a) 250 mm dia.

20.00 Mtr

b 100 mm dia. 100.00 Mtr

128

Providing and laying ISI marked PVC pipe having 6Kg /

Cm2 (Class 3) to be erected at road crossing or floor as

directed for laying of cable. The pipes as following size

of dia. & weight per 6 mtr. (a) 50 mm dia. (2.5 kg / 6

RMT)

500.00 Mtr

129

Providing and fixing heavy duty flange type brass cable

gland with rubber ring for PVC insulated armoured

cable complete with outgoing tails, insulating tape etc

for following size of cables (a) 2 to 4 core 4 sq.mm

400.00 Ea.

b 2 to 4 core 6 sq.mm 200.00 Ea.

BOQ/15

Page 16: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

130

Providing and fixing heavy duty flange type brass

cable gland with rubber ring for PVC insulated

armoured cable complete with outgoing tails, insulating

tape etc for following size of cables (a) 3 1/2/ 4 core

25 sq.mm

4.00 Ea.

b 3 1/2 core 70 sq.mm 4.00 Ea.

c 3 1/2 core 95 sq.mm 6.00 Ea.

131

Solderless crimping type Aluminum lugs conforming to

IS suitable for cable of following size evenly crimped

with high pressure tool & connected to switchgear

terminals with brass / cadmium plated nut bolts in

approved manner (a) 16 sq.mm

4.00 Ea.

b 25 sq.mm 8.00 Ea.

c 35 sq.mm 2.00 Ea.

d 50 sq.mm 4.00 Ea.

e 70 sq.mm 6.00 Ea.

f 95 sq.mm 12.00 Ea.

132

Solderless crimping type Copper lugs conforming to IS

suitable for cable of following size evenly crimped with

high pressure tool & connected to switchgear terminals

with brass / cadmium plated nut bolts in approved

manner (a) 2.5 to 6 sq.mm

1600.00 Ea

133

Approved make Ceiling Fan with Condenser 230 volt

A.C.50 Cys. 1200 mm sweep complete having 4 blades

with decorative brass finish body’ alluminium blades

decorative shanks on four blades with under light

arrangement on motor unit, canopy & 30 cms. down

rod erected with 24/ 0.2 flat 3 core flexible wire with

earthing.(Add Rs. 80/- Extra for Resistant type Fan

regulator)

215.00 Ea.

134

Approved Make Power Saving 50 Watt Ceiling Fan

with Condenser 230 volt AC. 50 Cys 1200 mm sweep

complete having 3 blades with aluminium blades with

canopy & 30 cms. Down rod erected with 24/0.2 flat 3

core flexible wire with earthing (Havells, Orient,

Crompton, Anchor, Bajaj, Usha)

20.00 Ea.

135

Supplying & erecting 19/20 mm nominal bore Medium

Class M.S Pipe down rod erected duly painted for fan

complete with necessary 24/o. a 2 .flat 3 core flexible

wire with earthing

251.00 Ea.

136

Supplying & erecting Fan Hook of 10 mm M.S.

Roundbar grouted in RCC slab with making the site as

original.

251.00 Ea.

137

Supplying and erecting approved make reversible

fresh air cum exhaust fan having size 305 mm 1400

RPM with regulator. Cat II

12.00 Ea.

138

Supplying and erecting approved make osillating type

bracket fan A.C. 23OV. 50C400/450 mm sweep wall

mounted with height adjustment and rotary tilting device

complete with guard, 3 core flexible Core & 3 pin plug

top complete erected on polish wooden block on wall

or.Ceiling with lead recorrections. complete Cat.II

32.00 Ea.

139

Providing and erecting stainless steel body water

cooler having storage capacity 150 Lts. & cooling

capacity 150 Ltr. Per hour @an ambient temp of 35 C.

The outlet temp. of the water should drop by 15 C

within a hour, if the water is fed @ 32 C. The water

cooler should be comprising of hermetically sealed

compressor, fan motor, condensing unit, water tank

surrounded by eveporating coil, thermostats, relay etc.

complete with necessary inlet & outlet connection

3.00 Ea.

BOQ/16

Page 17: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

140

Conveyance charges including loading / unloading for

Water Cooler from store to site (a) Local up to 10 Km 3.00 Ea.

141Add for 16 guage stainless steel baseplate Add. In item

No. 8-7-1 & 8-7-23.00 Ea.

142

Supplying and erecting water filter cum purifier with

ultraviolate technology. (Aquaguard / waterdoc model or

equivalent symphony/ crystal / videocon model3.00 Ea.

143

Supplying and erecting approved make online Un-

interruptible Power Supply system comprising flat

cum boost charger static. Inverter & sealed

maintenance free batteries. The charger having

operating capacity for input 10-270V AC & inverter

having output 230V, 50 Hz AC with 0.8 load power

factor with battery, over under voltage output with over

load & short circuit protection equipment. The system

housed in CRC sheet duly powder coated paid with

following capacity & with Following size of batteries (a)

1 KVA with 4 nos. of 12V, 65 AH SMF batteries for 3

Hr backup

1.00 Ea.

Supply, installation, testing and commissioning of Main

Panel cum meter board panel with seperate

compartment for KWH meter and switchgear

compartment.All compartment shall have locking

arrangement etc. complete as per drawing and

specification duly fabricated from 14 / 16 SWG CRCA

sheet, painted with seven tank processed, approved

epoxy paints complete with following components, with

internal wiring using appropriate rated wires, lugs, cable

ties, terminal blocks, copper busbars, copper earth

busbar, knock outs for cable entries, m.s. channel base

frame etc. as per drawing and specifications complete

'- All ACBs / MCCBs / MCBs to be CAT-III.'- All

MCCBs shall be ICS = 100 % of ICS' - Fabrication of

Cup board (Panel) shall be as per SOR # 3-17-1 (A)

CPRI approved factory (a) Main Panel '- 200 A, 35 kA

TP MCCB (1 no.) as Incoming. - CAT III'- 200 A,

440V, 50 Hz., TPN, Copper Busbars - Busbars should

be Four equal nos of electrolyte bus duly wraped with

colour insulating tape with necessary epoxy busbar

supports etc.

- Phase Indicating Lamps - Cat III

- Digital Multifunction meter - Voltage, Amperes &

Frequency only) with CTs coils - Cat III

- 63 / 40 A FP MCB - 10 kA 12 nos.) - Cat III

- 24 Hours, 7 Days Timer (6 Nos)

- 40 A, 440V, FP Timer (6 Nos)

- 40 A DP MCB - 10 kA (2nos.)- Cat III

144 1.00 nos.

BOQ/17

Page 18: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

145

Supply, testing and commissioning of Out door Metallic

Double door Feeder Pillar as per drawing and

specifications. Feeder Pillar should be dust and vermin

proof. Feeder Pillar shall be fabricated from 14 /16

SWG CRCA sheet metal duly painted with seven tank

process of approved paints. Feeder Pillar consisting of

following: Feeder Pillar Incoming : 80 AMP TP MCCB

(25KA), '- 100 A, 440V, 50 Hz., TPN, Copper Busbars,

Outgoing :- '- 40 AMP FP MCB (2 NOS) 10 KA, '- 40

AMP DP MCB (4 NOS) 10 KA, '- 40 AMP FP Power

Contactor (1 no), '- 24 Hour, 7 Days, Timer (1 no)

4.00 nos.

146

Supply, installation, testing and commissioning of

Decorative outdoor light fixture suitable to mounting

on pipe with 18 / 26 W PL tube (Re-trofit) with lamp

holder complete as per requirements (Basic Rate of

Fixture with lamp Rs. 450/-)514.00 nos.

147

Supply and erection of 750 mm long 32 mm dia, B

Class GI pipe duly burried / casted in brick masonery /

RCC for external lightings complete with painted with

one coat of red oxide paint with two coats of

allumunium paint complete to the satisfaction of E.I.C 414.00 nos.

148

Providing, installing, testing and commissioning of

50mm dia. G.I. `B' - Class pole with top reducer with

piece GI pipe suitable to erecting lighting fixture as per

drawing with 2 or 3 nos of G.I. pipe 25 mm dia. for

cable entries duly casted all in a 1:2:4 concrete

foundation with water tight SMC junction box with

terminal strip of Elmex make complete as per IS 2713.

The pole shall be 3.0 mtr. long with reducer on top for

installing fixtures and shall be painted with one coat of

red oxide paint and two coats of allumunium paint

complete to the satisfaction of Architect/Consultant

52.00 nos.

Supply, design, manufacture, transport, installation,

testing and commissioning of the complete lighting

system, using raising and lowering type of 20 Mts High

Mast Tower, including the Civil Foundation Works. (As

per Detail Specification Given). Only provide the supply

point and the feeder cable of the required size, up to the

bottom of the high mast. However, all items required for

the safe and efficient operation and maintenance of the

lighting system, including the high mast, whether

explicitly stated below or not, shall be included by the

Vendor

BOQ/18

Page 19: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

20 Meters High Mast system with all accessories

including but not restricted to the following. a) Mast

shaft in two section, hot dip galvanised and suitable for

wind velocity as per IS 875 part 3. b)

Head frame,steel wire rope of min. 6mm dia., double

drum winch. c) Galvanised Lantern carriage

arrangement suitable for 12 nos. luminaires & its control

gear boxes and Lightning finial. d) Integral power tool

installed inside base compartment for its operation. e)

Supply of foundation bolts manufactured from special

steel along with nuts, washers, anchor plate and

templates f) High Mast Foundation : - Design & casting

of R.C.C foundation with M-20 cement concrete & steel

reinforcement suitable for installation of 20 Mtr High

Mast. The complete foundation design & calculations

after testing the load bearing capacity of the soil duly

certified by the structural Engineer shall be submitted

by the firm before laying the foundations.

150

Supply & erection of 2 x 400 Watt non-integral type

flood light luminaries (IP-65) of Make GE / Philips /

Bajaj suitable for 2 x 400 watt Metal Halide lamp

complete with wide beam Reflector toughened glass,

mounting arrangement and separate aluminum case

control gear box having two number copper ballast,

igniter and P.F. improvement capacitor duly wired. The

housing of luminary should be made of pressure die

cast aluminium alloy powder coated. The fitting &

control gear box is to be mounted on existing lantern of

the High Mast with GI nut and bolts suitably. The fitting

shall be of type RVP 301 Philips or its equivalent of

Bajaj or Crompton .The fitting shall be provided with

Metal Halide lamp of 400 watt of Philips / HPI-T plus

tubular or its equivalent of Osram / GE. The job

includes cost of complete fitting, control gear with parts,

two Nos. 400 watt M.H. lamps, making connection of

fitting in existing junction box with 3x 2.5mm flexible

PVC insulated PVC sheathed copper conductor cable

of ISI make testinsupports

etc.

12.00 nos.

151

Supply & erection of LED Aviation Obstruction light

fixture (IP-65) of Make GE / Philips / Bajaj with lamp,

control gear etc complete with necessary mounting

arrangement and to be mounted on existing lantern of

the High Mast with GI nut and bolts suitably. The fitting

shall be of Bajaj Cat Ref: BJAOL1 /C1. type or its

equivalent of Philips / Binay. Including making

connection of fitting in existing junction box with 3x

2.5mm flexible PVC insulated PVC sheathed copper

conductor cable of ISI make testing etc. required to

complete the job to the entire satisfaction of Engineer-in-

charge.

1.00 NOS

1.00 nos.149

BOQ/19

Page 20: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

152

Well excavation by sinking: Sinking single circular

well of internal diameter and thickness of steining as

specified upto the level as specified in all sorts of soil

including hard murrum, boulders and all strata type &

strata upto the level as per drawing by dredging,

dewatering, drop chiselling with necessary kentiedge

and with machianical means as may be necessary for

this type of work including all labour, plant machinary

etc. complete. Zero level to be considered from cutting

edge level. (a) 0 to 3.00 mt depth

3.00 RMT

b Beyond 3.01 mt upto 6.0 mt depth 3.00 RMT

c Beyond 6.01 mt to 9.0 mt depth 3.00 RMT

153

Cutting Edge: Providing fabricating and placing cutting

edge and curbs as per design and drawing

manufactured from structural steel or M.S.Plate

confirming to ISS 226-1962 including reiverting welding

etc. complete 1) M.S. Bars, Anchor Bolts, Structural

steel and plates

3.00 QTL

154

Shoring and Strutting to trench:Providing and fixing

shoring and strutting to the trench including scnating

such as 50 mm thick planks runners, props etc

complete

125.60 SMT

155

Masonary for Well Staining: Masonary for well

staining in C.M. 1:6 above ground level and upto 1.5 mt

depth below average ground level a) Using burnt brick

of standard size

6.59 CMT

bFor additional depth of 1.5 m or part there of beyond 1.5

m depth6.59 CMT

cFor additional depth of 1.5 m or part there of beyond 1.5

m depth6.59 CMT

d For additional depth of 1.5 m or part there of beyond

1.5 m depth6.59 CMT

e For additional depth of 1.5 m or part there of beyond

1.5 m depth4.40 CMT

156

Cement Plaster of Wells A) Cement Plaster 20

mm thick rough coat with C.M. 1:3 including watering

curing etc. complete for well

125.60 CMT

bExtra for niru or cement finishing including watering

and curing for well125.60 CMT

157

Providing and supplying DI K-9 grade pipes with

internal cement mortar lining including all taxes,

insurance, transporation, freight charges, octroi,

inspection charges, loading, unloading, conveyance to

departmental stores, stacking etc.comp.

138.00 RMT

158

Manufacture, supply & delivery of D.I.specials plain &

Socket or flanged suitable to D.I.K-9 pipe.

(a) Upto 350mm Dia

170.00 kg.

159

Providing and supplying ISI mark CI D/F Sluice valves

, butterfly valves & Reflux valves of following class and

diameter including all taxes, insurance, transportation,

freight charges, octroi, inspection charges, loading,

unloading, conveyance to departmental stores, stacking

etc. comp. Sluice valves as per IS - 780 & 2906 / 1984

FOR 138 RMT (a) 100

1.00 No.

b 100 1.00 No.

160

Providing and supplying C. I. Air valves of approved

make & quality of following class and diameter including

all taxes, insurance, transportation, freight charges,

octroi, inspection charges, loading, unloading,

conveyance to departmental stores, stacking etc.comp.

Air valves single ball Flanged / screwed type (Air valve

double ball flanged) (a) 100mm

1.00 No.

BOQ/20

Page 21: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

161

Providing and supplying C. I. Scour valves/Stop

valves of approved make & quality of following class

and diameter including all taxes, insurance,

transportation, freight charges, octroi, inspection

charges, loading, unloading, conveyance to

departmental (a) 100mm

1.00 No.

162

Excavation for pipe line trenches incl. all safety

provisions using site rails and stacking excavated stuff

up to a lead of 90 mts. cleaning the site etc. complete

for lifts and strata as specified. 0 to 1.5 m. depth (a) In

all sorts of soil and soft murrum

136.00 M3

163

Excavation for pipe line trenches incl. all safety

provisions using site rails and stacking excavated stuff

up to a lead of 90 mts. cleaning the site etc. complete

for lifts and strata as specified. (a) In hard murrum,

boulders incl. macadam road.

1.00 M3

164

Lowering and jointing CI S&S spun pipes suitable for

tyton joints/ Mortarlined DI k-9 pipes of various classes

with CI/DI specials of following diameters in proper

position grade and alignment as directed by engineer- in-

charge including conveyance from store to site of work,

labour, giving hydraulic testing etc. complete (IS-

8329/1999 DI PIPE) DI K-9 pipe (a) 100mm

135.00 RMT

165

Lowering, laying and jointing in position following C. I. /

D/F Reflux valves, Butterfly valves, Sluice valves and

Air valves including cost of all labour, jointing material,

including nut bolts and giving satisfactory hydraulic

testing, etc. complete (Rate for all calss of valves) (a)

100mm

1.00 No.

166

Lowering, laying and jointing in position following C. I. /

D/F Reflux valves, Butterfly valves, Sluice valves and

Air valves including cost of all labour, jointing material,

including nut bolts and giving satisfactory hydraulic

testing, etc. complete (Rate for all calss of valves) (a)

Sluice valve/BF valve for 100mm

1.00 No.

167

Construction of valves chambers in brick or bela stone

masonary, locally available in C. M. 1:6.Foundation

concrete 150 mm thick in C. C. 1:4:8of trap metal size

25 mm to 40 mm thick, inside cement plaster in C. M.

1:3 and cement pointing outside in C. M. 1:3 and top

cover of precast RCC slab 100 mm thick (with key

hole in two parts, each with handles or MS Bar etc.

complete as give size) Upto 1 Mt. depth from G. L. to

pipe invert level incl. complete civil works but excl. cost

of excavation and refilling. WIth cast in situ RCC

slab in one single piece with fixing of CI-MH Frame and

cover (excl. cost of CI-MH Frame and cover) (a) 1.30 x

1.30 x 1.0m size

2.00 No.

168Providing CI MH frame and cover light duty 50 to 75

kg. Weight for water supply150.00 kg.

169

Refilling the pipeline trenches incl. ramming, watering,

consolidating desposal of surplus stuff as directed

within a radius of 3 km

135.00 M3

170

Providing C.C.M.:100 for encasing pipes using trap

metal size 12 mm to 50 mm incl. form work curing

consolidation etc. complete.

4.05 CMT

171

Providing and casting in situ mass cement concrete in

1:4:8 proportion using granite quartizite trap metal of

size 25mm to 40mm incl. consolidation curing etc.

complete.

18.23 CMT

BOQ/21

Page 22: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

172

Providing and casting in situ C.C. in grade M-150

(approx corresp. To prop. 1:2:4) using granite,

quartizite trap metal of size 6mm to 20mm for RCC

work, incl. scaffolding centering, form work, needle

vibrated cosolidation, curing comp. upto 6 metre depth

or height (excl. cost of reinforcement and neat finishing)

with centering & shuttering etc. complete. for structure

other than water retaining.

12.15 CMT

173Control Board for Submersible pump detailed

specification as per GWSSB R/C (8 HP) 4.00 No.

17400V grade AI conductor XLPE insulated power cable

(a) 3.5c x 35sq.mm. Al XLPE150.00 MT

b 3.5 c x 25 sq.mm. AL XLPE 150.00 MT

c 3c x 2.5 sq.mm YWY 150.00 MT

175

Single compression brass cable glands and crimping

type Bimetalic lugs/sockets with necessary tools and

equipments (a) 3.5c x 35sq.mm. AL XLPE4.00 MT

b 3.5 c x 25 sq.mm. AL XLPE 4.00 MT

c 3c x 2.5 sq.mm YWY 4.00 MT

176

Digging of earth pits of 1000 x 1000 x 300mm &

provided earth electrode of 50 mm N.B. 3.0 mtr. Long

G.I. Pipe type earthing. The scope also including

excavation, making brick masonary chamber & CI

hinged cover etc. complete

2.00 No.

a 25 x 6 G.I. strips 50.00 MT

177

Safety accessories complete with necessary fixing

brackets, other accessories and tools etc. (a) 4.5Kg.

Co2 type portable fire extinguisher with necessary fixing

brackets, other accessories and tools etc.

2.00 No.

bFirst Aid box complete with all standard medical items

2.00 No.

c First Aid Chart framed in glassed wooden frame 2.00 No.

dfire buckets with floor / wall mounting stand and other

required accessories4.00 No.

e2 x 20 W PL lamp operated self contained emergency

light with all required accessories1.00 No.

f1.1 KV grade 1000mm wide rubber insulating mat at

each MCC room.1.00 No.

178SPARES, TOOLS AND TEST Sewage

Submersible Pump1.00 LOT

a

Sewage non-clog submersible pump of required

capacity, head & minimum solid handling capacity of

100mm with 1.5 to 2 % ni.C.I. casing, SS CF8M

impeller to be operated on 3 phase, 415 V, 50 Hz., AC

suppply, 1500 RPM synchronous speed 1 DWF

FLOW PUMPS Capacity : 28 LPS, 5 HP , Head :

34 mtr.

1.00 No.

179

VALVES Double flanged C.I sluice valves, gear

operated with all other necessary SS hardwares, etc.

along with spare parts complete. (a) 1

DWF FLOW PUMPS Size: 100mm NB

1.00 No.

b

Double flanged C.I. Non Return Valve conforming to IS

5312 Part 1 with all stainless steel hardwares and

gaskets, etc 1 DWF FLOW PUMPS Size : 100 mm

NB

1.00 No.

180

PIPES AND SPECIALS (a) DI double flanged delivery

and header flanged pipe conforming to relevant

standard with connection complete (a) 100MM NB15.00 MT

bFlanged D.I 90 deg long bend conforming to relevant IS.

Size: 100MM NB150.00 kg

BOQ/22

Page 23: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

cDuctile Iron flnaged tee conforming to relevant IS Size:

200MM x 150 MM x 200MM (I)100.00 kg

d Ductile Iron 90 deg Duck foot bend

Size : 100 mm NB 150.00 kg

e Ductile Iron flanged conforming to relevant IS

Size : 100 mm NB 100.00 kg

181

CHAIN PULLEY BLOCK

Chain Pulley Block with tripple gear arrangement, lifting

book, load chain and hand chain, locking device with

necessary mounting girder/structre, spur gear travelling

trolley and all other accessories Capacity: 1 ton

Size: 100mm NB

1.00 No.

182 CAPACITY OF ESR Designing structurally (and

aesthetically) complying provisions of relevant Indian

standards and constructing RCC Elevated service

Reservoir of the following capacity and height , using

data of S.B.C of proposed site , Seismic zone, Wind

speed Zone. Up to staging height (L.S.L.) 12m from

G.L. And S.B.C. 10 t/Sq.M. Capacity of proposed

ESR - 300000 litre, Height of proposed ESR (Elevation)

- 12mt high, Cost of 300000 lakh litre capacity and

12mt highOther detail in tencial specification.Also all

work including as per Architect design

1 Jobs

183

Providing and supplying in standard length ISI mark

High Density polyethylene HDPE pipes 6 kg/sq.cm

suitable for potable water as per ISI specification

number 4984/1995 inclduing all local and central taxes,

transportation freight charges, octroi, inspection

charges, loading/unloading, conveyance to

departmental stores, stacking etc. complete. PE-100

Basic Rate Rs 79509/- Per MT (a) 75MM

1255.00 Rmt

184

Providing and supplying ISI mark CI D/F Sluice valves

, butterfly valves & Reflux valves of following class and

diameter including all taxes, insurance, transportation,

freight charges, octroi, inspection charges, loading,

unloading, conveyance to departmental stores, stacking

etc. comp. Sluice valves as per IS - 780 & 2906 / 1984

(a) 80MM dia

3.00 No.

185

Providing and supplying C. I. Air valves of approved

make & quality of following class and diameter including

all taxes, insurance, transportation, freight charges,

octroi, inspection charges, loading, unloading,

conveyance to departmental stores, stacking etc.comp.

Air valves single ball Flanged / screwed type (Air valve

double ball flanged) (a) 80mm Dia

3.00 No.

186Providing and fixing couplers 6 Kg/cm2 including

cutting etc complete (a) 75mm dia22.00 No.

187Providing and fixing Tees Heavy duty including cutting

etc complete (a) 90x758.00 No.

188Providing and fixing L bows Heavy duty including

cutting etc complete (a) 75mm dia14.00 No.

189Providing and fixing Reducers Heavy duty including

cutting etc complete (a) 90x753.00 No.

190Providing and fixing Bend 90 degree Heavy duty

including cutting etc complete (a) 75mm dia14.00 No.

191

Providing and fixing Reducers Heavy duty including

cutting etc complete (a) In all sorts of soil and soft

murum

132.90 M3

BOQ/23

Page 24: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

192

Lowering laying and jointing HDPE pipes and specials

of following class and diameter including cost of

conveyance from store to site of work, labour, giving

hydraulic testing as per ISI code (a) 75MM

1230.00 RMT

193

Lowering, laying and jointing in position following C. I. /

D/F Reflux valves, Butterfly valves, Sluice valves and

Air valves including cost of all labour, jointing material,

including nut bolts and giving satisfactory hydraulic

testing, etc. complete (Rate for all class of valves) (a)

80mm dia

3.00 No.

194

Lowering, laying and jointing in position following C. I. /

D/F Reflux valves, Butterfly valves, Sluice valves and

Air valves including cost of all labour, jointing material,

including nut bolts and giving satisfactory hydraulic

testing, etc. complete (Rate for all class of valves) (a)

80mm dia air valve

3.00 No.

195

Construction of valves chambers in brick or bela stone

masonary, locally available in C. M. 1:6.Foundation

concrete 150 mm thick in C. C. 1:4:8of trap metal size

25 mm to 40 mm thick, inside cement plaster in C. M.

1:3 and cement pointing outside in C. M. 1:3 and top

cover of precast RCC slab 100 mm thick (with key

hole in two parts, each with handles or MS Bar etc.

complete as give size) Upto 1 Mt. depth from G. L. to

pipe invert level incl. complete civil works but excl. cost

of excavation and refilling. WIth cast in situ RCC

slab in one single piece with fixing of CI-MH Frame and

cover (excl. cost of CI-MH Frame and cover) (a)

0.60x0.60x1.0m size

1.00 No.

196Providing CI MH frame and cover light duty 50 to 75 kg.

Weight for water supply750.00 No.

197

Refilling the pipeline trenches incl. ramming, watering,

consolidating desposal of surplus stuff as directed

within a radius of 3 km

881.00 M3

198

Providing and casting in situ mass cement concrete

in 1:4:8 proportion using granite quartizite trap metal of

size 25mm to 40mm incl. consolidation curing etc.

complete.

70.00 CMT

199

EXPOSED BRICK WORK FOR FORT WALL

RESTORATION Providing and restoring/maintaining of

architectural work of brick work with traditional lime

mortar including cleaning all joints, sizing, stone water

outlet,etc complete.

2997.75 smt

200

CLEANING OF WALL FOR FORT WALL

RESTORATION Cleaning of entire inside and outside

of fort wall as per given remedies and specification from

Architect.

To remove all kinds of algae/fungus erode plaster,

stone particles, and paint on the exposed brick wall,

with water jet cleaning and scrubbing the surface

5558.00 smt

201

FACE LIFTING FOR FORT WALL RESTORATION

Main gate of north and east side apply face lifting on

outside and as well as inside also

clean the entire surface of inside and outside removing

all layers of colours,lime wash,steel jali/brick work etc.

and

to restore all missing part of wood and stone pieces and

redoing the missing motif plaster after this apply

traditional lime plaster on entire surface.

2.00 Nos

BOQ/24

Page 25: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

202

WEEDIFICATION FOR FORT WALL RESTORATION

Removing the all unwanted plants/roots with proper

applying with non acidic weed killer material, on all small

and big we edification area of fort wall.

6.00 Jobs

203

SMOOTH PLASTER FOR FORT WALL

RESTORATION Applying traditional lime plaster on

the fort wall

proportion of 1:3 (lime:sand) with traditional method like

seiving,slaking, crushing and knocking etc

and also use of only natural additives in lime mortar,

using approved quality lime cured as per standards, to

match with existing quality of mortar and plaster,

applied and cured as per standards

5372.75 Sq.M.

204

REMOVING PARTS FOR FORT WALL

RESTORATION remove from existing position

(A)on the north side of fort wall and near a north gate

there is a toilets/bathrooms area.

(B)all south side shops are cover the entire south side

fort wall.

350.00 Sq.M.

205

STONE WORK FOR FORT WALL RESTORATION

Providing and applying stone carving, masonary work

and restoring all kind of stone work in order to match

with existing quality and carving on stone as per

directions from architect.

50.00 Smt

206

STRUCTURAL CRACK FOR FORT WALL

RESTORATION open all cracks in a "V" groove manner

and

grout a lime mortar in a crack's cavity portion on a

interaval of 2-3 days

and on a some equal interval put a big size of stone

clipping after that

the top surface of crack will repair with traditional lime

mortar

750.00 Rmt

207

WOOD WORK FOR FORT WALL RESTORATION .

The main wood work is on both north and south gate by

bringing down the door, removing the old paint layer,

clearing the surface with sand paper, repairing of all

parts of doors, applying the wood filler on entire

surface, applying 3 coat of color as per consultant and

architect instruction, etc.

160.00 Cmt

208

STONE CLADDING FOR FORT WALL

RESTORATION Providing and fixing Sand Stone

(Dhangadhara) with dry cladding method and using

Silicon base joint filler (Lime Appropriate) 465.00 Smt

209

ILLUMINATION OF FORT WALL AS FORT WALL

RESTORATION as per norms for monuments and

directions from architect in order to highlight the Fort

Wall and enhance visiblitity from far distance.6.00 Nos

BOQ/25

Page 26: BOQ Financial

Planning Solution Tourism Corporation of Guajrat Ltd(TCGL)

210

CONSTRUCTION OF NEW GATE AS FORT WALL

RESTORATION as per given drawing and directions

from architect, taking care not to harm the existing

structure during breakage proces inclusive of temporary

arrangements, to close entry to Temple from work area.

(AS PER GIVEN DRAWING)

10.00 Smt

211

REMONGING OF WALL FOR EAST GATE

Removing the part of Fort Wall for construction of East

Gate for entire Fort Wall thickness, Removing all

materials which used in Fort Wall and Collect the same

material for Exposed Brick Work Restoration work

46.30 cmt

212

Providing and laying controlled cement concrete M -

200and curing complete excluding the cost of form

work and reinforcement for reinforced concrete

work.All work

75.00 cmt

BOQ/26