Bollard Installation Sheet Mounted Decorative Area Light CorTen Steel Series BOLLARD: 12V Solid CorTen Steel Light Bollard For use with Low Voltage Landscape Lighting Power units. FOR OUTDOOR USE ONLY. Amps not to exceed: 25 AMPS; Volts not to exceed: 15 Volts. If using halogen, do not exceed 12V at the luminaire. If using LED, optimal operating range is 10V-14V. WARNING: Luminaire must be installed in accordance with National Electric Code (NEC) and Local Codes. Failure to do so will void all warranties and may result in serious injury and/or damage to the luminaire. SAFETY WARNING: Luminaire can become very hot depending on the lamp wattage used. Lens and metal around lamp can become hot enough to blister hands. Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used. LUMINAIRES ARE NOT TO BE INSTALLED WITH 10 FT. (3.03M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”. WHEN USING MULTIPLE LUMINARES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS ON POWER UNITS. LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY. NOTE: Use UL rated wire connectors, low voltage power units, cable, and all other components. CL-Bollard CorTen Solid Steel Area Light R ClaroLux, LLC - www.ClaroLux.com - PO Box 4554 Greensboro, NC 27405 - (336) 378-6800 - (866) 668 - LITE (5483) Plan Symbol: IMPORTANT SAFETY INSTRUCTIONS - THE LIGHTED LAMP IS HOT! WARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS: 1) Turn off/unplug and allow to cool before replacing lamp. 2) Lamps get hot quickly! Only contact switch/plug when turning on. 3) Do not touch hot lens, shroud or enclosure. 4) Keep lamp away from material that may burn. 5) Do not touch lamp at any time. Use a soft cloth. Oil from skin may damage lamp. 6) Do not operate luminaire fitting with a missing or damaged cover. LAMP INSTALLATION & REPLACEMENT: CAUTION: Do not exceed maximum wattage marked on luminaire label. 1) To prevent electrical shock, disconnect transformer from electrical supply before service. 2) Remove shroud/top to expose lamp. 3) Replace lamp with correct wattage and type marked on fixture label. NOTE: DO NOT touch lamp with bare hands. Always use soft cloth or the plastic wrapping (if available) from lamp to handle lamp. 4) Re-install shroud/top of luminaire. SAVE THESE INSTRUCTIONS: Leave with property owner/manager Fig. 1.1 Fig. 1.2 4. Once the concrete has cured, posion the lantern base on the foong how you want it oriented and mark your wedge anchor pilot holes. Refer to Fig 1.2 5. Using a carbide pped 3/8 drill bit (sold separately ), drill your pilot holes in your marked locaons and insert the wedge anchors (sold separately ) Fig. 1.3 6. Place the lantern base back onto the foong lined up with your anchors and ghten down the nut and washer (sold separately ) unl base is firmly planted. Refer to Fig. 1.3 7. Using at least two people gently p the lantern back onto the base making sure to first pull the wire through the wire port. Replace the bolts around the base and e the wire ends into a low voltage power supply (sold separately ) 1. Using a concrete tube form pour a concrete foong. Refer to Table A.1 for suggested sizes Lantern Footprint Suggested Footing Size 6” x 6” 8”W x 6”D 8” x 8” 8”W x 18”D 11” x 11” 10”W x 24”D 14” x 14” 12”W x 42”D Table A.1 3. Remove the base from the lantern by unscrewing the 8 bolts around the boom and gently laying the lantern on its side. The base will easily pull out. Refer to Fig. 1.1 2. Make sure the concrete pad is level and let it cure for the amount of me specied by your supplier

Transcript of Bollard Installation Sheet - ClaroLux, LLC · Bollard Installation Sheet ... Luminaire must be...

Page 1: Bollard Installation Sheet - ClaroLux, LLC · Bollard Installation Sheet ... Luminaire must be installed in accordance with National Electric Code ... onto the base making sure to

Bollard Installation SheetMounted Decorative Area Light

CorTen Steel Series

BOLLARD: 12V Solid CorTen Steel Light Bollard

For use with Low Voltage Landscape Lighting Power units. FOR OUTDOOR USE ONLY. Amps not to exceed: 25 AMPS; Volts not to exceed: 15 Volts. If using halogen, do not exceed 12V at the luminaire. If using LED, optimal operating range is 10V-14V.

WARNING:Luminaire must be installed in accordance with National Electric Code (NEC) and Local Codes. Failure to do so will void all warranties and may result in serious injury and/or damage to the luminaire.

SAFETY WARNING:Luminaire can become very hot depending on the lamp wattage used. Lens and metal around lamp can become hot enough to blister hands. Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used. LUMINAIRES ARE NOT TO BE INSTALLED WITH 10 FT. (3.03M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”. WHEN USING MULTIPLE LUMINARES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS ON POWER UNITS. LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY. NOTE: Use UL rated wire connectors, low voltage power units, cable, and all other components.

CL-Bollard CorTen Solid Steel Area Light

R

ClaroLux, LLC - www.ClaroLux.com - PO Box 4554 Greensboro, NC 27405 - (336) 378-6800 - (866) 668 - LITE (5483)

Plan Symbol:

IMPORTANT SAFETY INSTRUCTIONS - THE LIGHTED LAMP IS HOT!

WARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:1) Turn off/unplug and allow to cool before replacing lamp.2) Lamps get hot quickly! Only contact switch/plug when turning on. 3) Do not touch hot lens, shroud or enclosure. 4) Keep lamp away from material that may burn.5) Do not touch lamp at any time. Use a soft cloth. Oil from skin may damage lamp.6) Do not operate luminaire fitting with a missing or damaged cover.

LAMP INSTALLATION & REPLACEMENT:CAUTION: Do not exceed maximum wattage marked on luminaire label.1) To prevent electrical shock, disconnect transformer from electrical supply before service.2) Remove shroud/top to expose lamp.3) Replace lamp with correct wattage and type marked on fixture label. NOTE: DO NOT touch lamp with bare hands. Always use soft cloth or the plastic wrapping (if available) from lamp to handle lamp. 4) Re-install shroud/top of luminaire.

SAVE THESE INSTRUCTIONS:Leave with property owner/manager

Fig. 1.1

Fig. 1.2

4. Once the concrete has cured, position the lantern base on the footing how you want it oriented and mark your wedge anchor pilot holes. Refer to Fig 1.2

5. Using a carbide tipped 3/8 drill bit (sold separately), drill your pilot holes in your marked locations and insert the wedge anchors (sold separately)

Fig. 1.3

6. Place the lantern base back onto the footing lined up with your anchors and tighten down the nut and washer (sold separately) until base is firmly planted. Refer to Fig. 1.3

7. Using at least two people gently tip the lantern back onto the base making sure to first pull the wire through the wire port. Replace the bolts around the base and tie the wire ends into a low voltage power supply (sold separately)

1. Using a concrete tube form pour a concrete footing. Refer to Table A.1 for suggested sizes

Lantern Footprint Suggested Footing Size

6” x 6” 8”W x 6”D

8” x 8” 8”W x 18”D 11” x 11” 10”W x 24”D

14” x 14” 12”W x 42”D

Tabl

e A

.1

3. Remove the base from the lantern by unscrewing the 8 bolts around the bottom and gently laying the lantern on its side. The base will easily pull out. Refer to Fig. 1.1

2. Make sure the concrete pad is level and let it cure for the amount of time specified by your supplier