BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables...

16
QUAT RE AU SMAR T TAP > T ECHNICAL SPECIFICAT ION QST-553-BCS —boiling, chilled and sparkling solutions .................................................................................................... BOILING CHILLED SPARKLING Model shown above QST-553-BCS Collection

Transcript of BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables...

Page 1: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QST-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BOILING

CHILLED

SPARKLING

Model shown above QST-553-BCS

Collection

Page 2: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

SPECIAL FEATURES

• Delivers high volumes of boiling, sparkling and chilled water• Fits into a standard 24” cabinet• Ventilation duct included for kick space installation• Low energy consumption• Highest performing insulation• Most robust and reliable system available• Dispenses 8 gallons piping hot (204-206°F) water per hour• Up to 15 mugs in one draw with no temperature drop & just 5-8 minutes recovery time• Delivers 5.3 gallons of chilled/sparkling water per hour at 40-45°F• Easy to use push button control with built-in safety feature• DDA compliant controls• 316 SS construction for optimum corrosion resistance• Controlled water flow• Manufactured in the UK• Leak detection as standard

quatreautaps.com2

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QST-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

CHILLED SPARKLINGBOILING

PRODUCT DISPENSE

EQUIPMENT DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• System is installed in component form• Standard cabinet (24” x 24” x 34.5”)• Individual components dimensions as on

drawing page

SITE PREPARATION DETAILS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Cold water supply terminating in shut off valveready for 1/4” compression fitting

• 2 dedicated 15amp 115V circuits• Maximum water pressure 60 psi• Minimum water pressure 45 psi• Minimum water flow 26.5 gallons per hour• Air gap connection* connected to Venturi

NOTES:

* supplied with equipment

3

LOCATION OF SERVICES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• All services to be located to the rear 4” ofsystem location

• Power to be located high in rear of cabinet• Water to be located at low level

Model shown QST-553-BCS

Model shown QST-553-BCS

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QST-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 4: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

TY

PIC

AL

IN

ST

AL

L D

IAG

RA

M

4

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QST-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 4

quatreautaps.com

Page 5: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

CUTTING TEMPLATE

NOTES:

Unless otherwise specified, dimensions are in millimeters.

5

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QST-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 6: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

PIL

OT

DR

ILL H

OLE

S

3B

7698-0

1 K

ICK

-BO

AR

D C

UT

TIN

G T

EM

PLA

TE

.

IMP

OR

TA

NT

: B

efo

re m

akin

g a

ny c

uts

into

the

cupboard

or

kic

k b

oard

, ensure

the

are

a to

be

cut is

fre

e fro

m w

ate

r pip

es o

r ele

ctr

ical cable

s.

There

is a

ris

k o

f serious inju

ry o

r death

if ele

ctr

ical cable

s a

re c

ut,

an

d s

ign

ific

an

t d

am

ag

e to

pro

pe

rty if a

wa

ter

pip

e is c

ut.

1.42"

1.46"

16.93"

2.44"

CU

T O

UT

LE

NG

TH

NO

T T

O S

CA

LE

Mark

and c

ut ducting to length

if

required u

sin

g the k

ick b

oard

as r

efe

rence.

Fit g

rill

over

the k

ick b

oard

cut out

usin

g the s

cre

ws s

upplie

d.

Use for:

Q-C

20, Q

-CS

20

VE

NT

ILA

TIO

N D

RA

WIN

GS

- K

ick

Bo

ard

Cu

ttin

g T

em

pla

te -

sa

mp

le o

nly

6

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QST-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 7: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

FO

LD

/CU

TA

LO

NG

TH

ISLIN

E.

ALIG

NT

OIN

SID

ELE

FT

SID

EO

FC

AB

INE

T.

FOLD/CUT ALONG THIS LINE.ALIGN TO REAR FACE OF CABINET.

IMPORTANT: Before making any cuts into the cupboard or kick board, ensure the area to be cut is free from water pipes or electrical cables.

There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut.

PILOT DRILL HOLES

1.97" 8.27"5.2"

1.89"

Use for: Q-C20, Q-CS20

VENTILATION DRAWINGS - Base Cutting Template - sample only

7

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QST-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 8: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QST-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WORLD TRADE CENTER - New York. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

One World Trade Center is the main building of the rebuilt World Trade Center complex in Lower Manhattan, New York City. One WTC is the tallest building in the United States, the tallest building in the Western Hemisphere, and the sixth-tallest in the world.

THE SHARD London. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The Shard, also infrequently referred to as the Shard of Glass, Shard London Bridge and formerly London Bridge Tower, is a 95-story super-tall skyscraper, designed by the Italian architect Renzo Piano, in Southwark, London, that forms part of the Shard Quarter development.

THE SCALPEL London. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The Scalpel is a commercial skyscraper in London, United Kingdom. It is located on Lime Street in the City of London financial area.

SALESFORCE TOWER - London. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

110 Bishopsgate (formerly Heron Tower now known as Salesforce Tower) is a commercial skyscraper in London. It stands 230 metres (755 ft) tall including its 28-metre (92 ft) mast making it the tallest building in the City of London financial district.

EXISTING INSTALLATIONS

We have clients enjoying our Quatreau Touch and SmartTaps (dispensing a variety of water types) in all of these buildings as well as in other commercial offices and prestigious homes across the globe.

Find out more at www.quatreautaps.com

Page 9: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QSTD-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BOILING

CHILLED

SPARKLING

Model shown above QSTD-553-BCS

Page 10: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

SPECIAL FEATURES

• Delivers high volumes of boiling, sparkling and chilled water• Fits into a standard 24” cabinet• Ventilation duct included for kick space installation• Low energy consumption• Highest performing insulation• Most robust and reliable system available• Dispenses 8 gallons piping hot (204-206°F) water per hour• Up to 15 mugs in one draw with no temperature drop & just 5-8 minutes recovery time• Delivers 5.3 gallons of chilled/sparkling water per hour at 40-45°F• Easy to use push button control with built-in safety feature• DDA compliant controls• 316 SS construction for optimum corrosion resistance• Controlled water flow• Plumbed to waste, flush-fitting drip tray• Manufactured in the UK• Leak detection as standard

2

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QSTD-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 11: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

CHILLED SPARKLINGBOILING

PRODUCT DISPENSE

EQUIPMENT DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• System is installed in component form• Standard cabinet (24” x 24” x 34.5”)• Individual components dimensions as on

drawing page

SITE PREPARATION DETAILS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Cold water supply terminating in shut off valveready for 1/4” compression fitting

• 2 dedicated 15amp 115V circuits• Maximum water pressure 60 psi• Minimum water pressure 45 psi• Minimum water flow 26.5 gallons per hour• Air gap connection* connected to Venturi

NOTES:

* supplied with equipment

3

LOCATION OF SERVICES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• All services to be located to the rear 4” ofsystem location

• Power to be located high in rear of cabinet• Water to be located at low level

Model shown QSTD-553-BCS

Model shown QSTD-553-BCS

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QSTD-553-BCS—boiling, chilled and sparkling solutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 12: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

TY

PIC

AL

IN

ST

AL

L D

IAG

RA

M

4

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QSTD-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 13: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

CUTTING TEMPLATE

NOTES:

Unless otherwise specified, dimensions are in mm.

5

15

2

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QSTD-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 14: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

PIL

OT

DR

ILL H

OLE

S

3B

7698-0

1 K

ICK

-BO

AR

D C

UT

TIN

G T

EM

PLA

TE

.

IMP

OR

TA

NT

: B

efo

re m

akin

g a

ny c

uts

into

the

cupboard

or

kic

k b

oard

, ensure

the

are

a to

be

cut is

fre

e fro

m w

ate

r pip

es o

r ele

ctr

ical cable

s.

There

is a

ris

k o

f serious inju

ry o

r death

if ele

ctr

ical cable

s a

re c

ut,

an

d s

ign

ific

an

t d

am

ag

e to

pro

pe

rty if a

wa

ter

pip

e is c

ut.

1.42"

1.46"

16.93"

2.44"

CU

T O

UT

LE

NG

TH

NO

T T

O S

CA

LE

Mark

and c

ut ducting to length

if

required u

sin

g the k

ick b

oard

as r

efe

rence.

Fit g

rill

over

the k

ick b

oard

cut out

usin

g the s

cre

ws s

upplie

d.

Use for:

Q-C

20, Q

-CS

20

VE

NT

ILA

TIO

N D

RA

WIN

GS

- K

ick

Bo

ard

Cu

ttin

g T

em

pla

te -

sa

mp

le o

nly

6

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QSTD-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 15: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

FO

LD

/CU

T A

LO

NG

TH

IS L

INE

.A

LIG

N T

O IN

SID

E L

EF

T S

IDE

OF

CA

BIN

ET

.

FOLD/CUT ALONG THIS LINE.ALIGN TO REAR FACE OF CABINET.

IMPORTANT: Before making any cuts into the cupboard or kick board, ensure the area to be cut is free from water pipes or electrical cables.

There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut.

PILOT DRILL HOLES

1.97" 8.27"5.2"

1.89"

Use for: Q-C20, Q-CS20

VENTILATION DRAWINGS - Base Cutting Template - sample only

7

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QSTD-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

quatreautaps.com

Page 16: BOILING CHILLED SPARKLING€¦ · There is a risk of serious injury or death if electrical cables are cut, and significant damage to property if a water pipe is cut. 3B7698-01 KICK-BOARD

QUAT RE AU SMAR T TAP > T ECHNICAL SPECIF ICAT ION

QSTD-553-BCS—boiling, chilled and sparkling solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WORLD TRADE CENTRE - New York. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

One World Trade Center is the main building of the rebuilt World Trade Center complex in Lower Manhattan, New York City. One WTC is the tallest building in the United States, the tallest building in the Western Hemisphere, and the sixth-tallest in the world.

THE SHARD London. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The Shard, also infrequently referred to as the Shard of Glass, Shard London Bridge and formerly London Bridge Tower, is a 95-story supertall skyscraper, designed by the Italian architect Renzo Piano, in Southwark, London, that forms part of the Shard Quarter development.

THE SCALPEL London. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The Scalpel is a commercial skyscraper in London, United Kingdom. It is located on Lime Street in the City of London financial area.

SALESFORCE TOWER - London. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

110 Bishopsgate (formerly Heron Tower now known as Salesforce Tower) is a commercial skyscraper in London. It stands 230 metres (755 ft) tall including its 28-metre (92 ft) mast making it the tallest building in the City of London financial district.

EXISTING INSTALLATIONS

We have clients enjoying our Quatreau Touch and SmartTaps (dispensing a variety of water types) in all of these buildings as well as in other commercial offices and prestigious homes across the globe.

Find out more at www.quatreautaps.com